Search Results

Search found 62736 results on 2510 pages for 'smart help'.

Page 240/2510 | < Previous Page | 236 237 238 239 240 241 242 243 244 245 246 247  | Next Page >

  • HP DL380 G5 Predictive failure of a new drive

    - by CharlieJ
    Consolidated Error Report: Controller: Smart Array P400 in slot 3 Device: Physical Drive 1I:1:1 Message: Predictive failure. We have an HP DL380 G5 server with two 72GB 15k SAS drives configured in RAID1. A couple weeks ago, the server reported a drive failure on Drive 1. We replaced the drive with a brand new HDD -- same spares number. A few days ago, the server started reporting a predictive drive failure on the new drive, in the same bay. Is it likely the new drive is bad... or more likely we have a bay failure problem? This is a production server, so any advice would be appreciated. I have another spare drive, so I can hot swap it if this is a fluke and new drive is just bad. THANKS! CharlieJ

    Read the article

  • GNU Emacs is crashing with -nw

    - by Jack
    When I run emacs with -nw option, the emacs really open, but I can't do more nothing. As if the user input is blocked and no keyboard signal is received and/or interpreted. I've tried run without load .emacs file and some other behaviors: emacs -nw -Q --no-desktop --debug-ini foo.c But makes no difference and strangely the GUI-version(using Gtk) is working fine. My gnu-emacs version is GNU Emacs 23.3.1 Any help to help to fix it is very appreciated.

    Read the article

  • migrate old bootable wd harddrive to new 500 gb hd which was just used for storage and has stored programs on it , id like 500gb to be botable

    - by tom
    id appreciate any help in this matter this is in laptop with 2 harddrive bays. i have a wd scorpio that has become 2 small its bootable with windows 7, i have pretty new 3 months old hitachi hd500gb i was using for storage-backup of programs it is not bootable and id like to make it that way without losing saved backed up info on it is there any way to do this, id like to keep only 500gb bootable hard drive due to weight of laptop its 10.lbs desktop replacement gateway p-7805u thanks for your help in advance on this matter, tommy

    Read the article

  • WPF & RenderTierCapability, what could cause a machine to be dropped from Tier 2 to 0?

    - by Erode
    I'm having an issue on some imaged machines where they will started out on Tier 2 and after some time of use (they are well spec'd kiosk machines, quad-core, Nvidia 550Ti), they drop to Tier 0 and effectively become useless. Restarting the machine doesn't seem to help. This is a problem more than just "missing hardware acceleration" because my application requires D3DImage to function (which requires Tier 2). Thanks for any help!

    Read the article

  • Url-based web site publishing on Windows Server platform

    - by Maxim V. Pavlov
    I have a Windows 2008 Enterprise SP2 server in a datacenter. It is 32bit OS. I need to be able to do a "smart" url-based web site publishing. So that with a single external IP I can publish many sites on port 80, and some firewall logic resolves, based on a requested URL, which site in IIS gets the request. Forefront TMG 2010 has this feature, but it is not supported on 32bit systems. Is there a software solution that can satissfy my need on Windows 2K8 platform? Thank you. P.S. Perhaps there is a workaround or a tweak to do what I need in IIS?

    Read the article

  • windows server 2012 wont boot after instlling on iscsi device

    - by Nandan
    Windows server 2012 installed on a ISCI LUN. Problem noticed after first reboot. Windows boots only if setup DVD is present(i have to ignore "press any key to boot from DVD" prompt). to present the login Screen and everything looks great from here. But the server wont boot without the help of setup DVD. Can any one help me understand what would be the problem? Dell Workstation T3600 Intel Pro NIC (Capable of ISCI Boot and also enabled)

    Read the article

  • Top causes of slow ssh logins

    - by Peter Lyons
    I'd love for one of you smart and helpful folks to post a list of common causes of delays during an ssh login. Specifically, there are 2 spots where I see a range from instantaneous to multi-second delays. Between issuing the ssh command and getting a login prompt and between entering the passphrase and having the shell load Now, specifically I'm looking at ssh details only here. Obviously network latency, speed of the hardware and OSes involved, complex login scripts, etc can cause delays. For context I ssh to a vast multitude of linux distributions and some Solaris hosts using mostly Ubuntu, CentOS, and MacOS X as my client systems. Almost all of the time, the ssh server configuration is unchanged from the OS's default settings. What ssh server configurations should I be interested in? Are there OS/kernel parameters that can be tuned? Login shell tricks? Etc?

    Read the article

  • NVidia raid 5 array spooling sounds and delay

    - by Chase B. Gale
    I've had a raid 5 array setup with 3 2TB WD Green drives for about 3 years now. Starting last week, when I would access the array for the first time, I hear a loud drive spooling sound and experience a ~5 second delay before being able to access\save files. This behavior happens when I don't use the array for some time (about an hour) and after occurring it doesn't happen again if I continue to access the array. I've run SMART scans on all drives and they come back as being a-ok. What's causing this? Is my array getting close to death?

    Read the article

  • Formula in table header cells

    - by Cylindric
    I have a table in Excel 2007 that I want to summarise, in a similar fashion to a Pivot Table, but for various reasons I can't use a pivot table. I like the "Format as table" features of sort and filter buttons, automatic formatting etc, so have used that to create a simple table: A B C N +-----------+------------+------------+-------+------------+ 1 | | 01/01/2010 | 01/02/2010 | ... | 01/12/2010 | +-----------+------------+------------+-------+------------+ 2 | CategoryA | 15 | 545 | | 634 | 3 | CategoryB | 32 | 332 | | 231 | 4 | CategoryC | 5 | 234 | | 644 | | ... | | | | | 27 | CategoryZ | 2 | 123 | | 64 | +-----------+------------+------------+-------+------------+ The numbers are retrieved from a "back-end" pivot table using GETPIVOTDATA(). All that works fine. Now, the problem is that I can't seem to use formulas for my column headings in these new "smart" tables - they are converted to text or just broken. For example if in B1 I put NOW(), I don't get the date, I get 00/01/1900. Is there any way of getting a formula to work in the auto tables? Or do I have to use standard tables and manually alternate-colour my rows etc?

    Read the article

  • Windows backups to VM Esxi

    - by Martyn
    I'm very new to ESXi, so apologies if this is a silly question. I have ESXi 5.1 running running on HP Proliant Microserver with internal LUNs RAIDed with HP P410 Smart Array card. I have 2 Windows Server 2012 VMs running as Domain controllers. These are being backed-up up with GhettoVCB to a dedicated datastore hosted on LUNs on a eSata external device. I have several Windows 8 & 7 PC's connected to this domain. I want to back up these Windows PCs, via the built in backup software, ideally to the external eSata device as well. What do I need to do to have the Windows PC's see the datastore? I assume I could create a VM for FreeNas or something, or share out the datastore via one of the Windows Server 2012 VMs. Both those options seem a little bit of an over kill?

    Read the article

  • Occasional HDD Related Hangs

    - by diolemo
    I have an issue that seems to be disk related. Occasionally my system will block for 30 or so seconds and is mostly unresponsive. Those things already in memory requiring no disk access continue to function but those things requiring disk access (even small) hang. 30 seconds later everything is back to normal. I have 2 Samsung drives in RAID 0. I have 1 WD drive (has pagefile) I have an SSD used for caching (Intel Smart Response). This is a new install of Windows and the drives were fine in my old PC (~1 month ago). Has anyone experienced anything similar? Any suggestions to solve this one? Thanks in advance.

    Read the article

  • Alias a linked Server in SQL server management studio?

    - by absentmindeduk
    Hoping someone can help - is there a way in SQL server management studio 2008 R2 that I can alias a linked SQL server? I have a server, added by IP address, to which I do not have the login credentials - however as the connection is already setup I can login ok. Issue is that, this is a dev environment, prior to a live deployment and the IP I have as a linked server needs to be 'accessible' by my stored procs under a different name, eg 'myserver' not 192.168.xxx.xxx... Any help much appreciated.

    Read the article

  • Replacing a non-failing drive in a RAID-0 array

    - by TallFurryMan
    I have a Windows 7 machine booting on a RAID-0 pair of 500GB disks, controlled by an ICH9R. One of those was indicating an end-To-end SMART failure, so I added a spare disk as a temporary workaround, before receiving another to replace the failing one. The RAID-0 rebuilt on the spare and dropped the failing one from the array, as expected. Now that I received the new drive, what are my options to reintegrate it in the array? My first thought was to simply clone the temporary disk to the new one while the array is offline, but shouldn't there be a way to force a second rebuild, just as if the temporary drive had a warning, and drop that temporary from the array?

    Read the article

  • Defrag/TRIM settings for hybrid hard drive?

    - by Joel Coehoorn
    I recently acquired a momentus XT hybrid hard drive. This is a tradition spinning HDD with a small SSD portion for frequently used files. Normally, you are not supposed to defrag SSDs, as it does not help performance and can significantly reduce the life of the drive. But you do need to defrag an HDD to keep good performance. So where does that leave us for hybrid drives? Do I need to turn off defragging in Windows to preserve the SSD portion? Is the on-disk controller smart enough to handle defragging correctly? Is there some utility I need to set it up that I missed? Additionally, for SSDs you normally want to check for and enable TRIM support... but this makes no sense for a HDDs. Where does that leave us for hybrid drives? Should I try to enable TRIM or not?

    Read the article

  • High IO latency on ESXi 4.1 on HP DL580 G7

    - by teddydestodes
    at my Company we were experiencing some weird spikes on IO latency on one of our ESXi instances. we've spend 24h figuring out whats wrong and no clue so far. after giving up we put all the disks into a different server (HP DL380 G7) with much less RAM and only one 6(HT) cores (from 12 on the DL 580) which run fine for about 2 hours. I dont know the specs for the DL380 but both servers have a Smart Array P410i with BBWC (the DL 580 has 1GB) Is it possible that one(or all) of the disks is failing without actually failing?

    Read the article

  • filtering itunes library items by file location

    - by Cawas
    The Problem I've got way more than 1000 duplicated items in my iTunes Library pointing to a non-existant place (the "where" under "get info" window), along with other duplicated items and other MIAs (Missing In Action). Is there any simple way to just delete all of them and only them? By that I mean some MIAs are pointing to /Volumes while some are pointing to .../music/Music/... or just .../music/.... I want to delete all pointing to /Volumes as to later I'll recover the rest. Check the image below. Some Background I tried searching for a specific key word on the path and creating smart play list, but with no result. Being able to just sort all library by path would be a perfect solution! I believe old iTunes could do that. PowerTunes can do it (sort by path) but I can't do anything with its list. Yes, all of the /Volumes look like that.

    Read the article

  • Can I mix drive types in an HP server?

    - by Generic Error
    I currently have the following setup: HP DL380 G4 Server 6 x 73GB, Ultra160, 10k, SCSI 80 Pin Drives Smart Array 6i Controller RAID 5 One of the drives is failing and needs to be replaced. I have on hand drives that are the same size and type, but are Ultra320, 15k instead. I have verified that these drives work in another system with the same type of drive controller. When I plug one of these in the system simply reports the drive as being offline and has nothing further to do with it. From what I have read these drives should be compatable. Should this work at all and if so, what might be preventing it?

    Read the article

  • Nginx config with try_files and rewrite : precedence?

    - by Penegal
    Good morning, everybody. Firstly, this question may have been already asked, but I searched ServerFault during about 15 minutes without finding it, so, if it was already asked, please accept my apologies. I'm trying to rationalize my Nginx server config, but I have a rather dumb question that I couldn't solve, even with extensive Web search, except if I totally f*cked my search. Here is the question : is try_files parsed before or after rewrite ? Asked differently, Do I have to put try_files after all rewrite directives, or is Nginx config parser smart enough to evaluate try_files after all relevant rewrite directives ? The link with the config rationalization is that the answer to this question will change the organisation of the config, ie if config file order of try_files and rewrite changes the config behaviour, it will force me to disperse my includes, some of them containing try_files and other ones containing rewrite, because I also have rewrite directly in nginx.conf. Hoping you can help me, Regards.

    Read the article

  • VMWare Input/Output error on ubuntu host Win7 guest

    - by CShipley
    I am running ubuntu 10.10 as my host with Windows 7 as the guest. About a couple weeks ago I started getting error pop-ups from vmware reporting inability to read or write to a particular file. On futher investigation, I've noticed that I cannot copy that particular file from the linux command line even as root. I get the same input/output error. The SMART utility tells me I have 69 bad sectors on the disk (it is 1 TB) So my question is 1) How do I tell if that HD is going bad? 2) How can I move the VM files to a different part of the disk if I get read/write errors when I try to copy?

    Read the article

  • Enterprise Data Center System Admin/Engineer to Server Ratio

    - by Bob
    I know there have been similar questions asked over the last few months however looking at a Data Center Operations and know there are some really smart people out there that might be able to help. Looking for some staffing best practices based on first hand experience and was hoping that there is some experience in this area that can provide "best practice" application: Three High Availability (99.99% plus) Enterprise Level Data Centers geographically dislocated, one manned 24x7x365, one lights out, one co-location running HOT-HOT-HOT supporting a global community. More than 2,000 operating systems consisting of 95% Windows, 5% Linux and Solaris, 45% virtualized, more than 100TB storage. No desktop support, no Network Administration (administrated separately), running N+1 and serving more than 250 Billion page views annually. Based on experience what has been your experience with Server to "Data Center System Administrator/Engineer" ratio? Thanks in advance for your responses.

    Read the article

  • Can an SSD notify the hosting OS that its wear level is getting high?

    - by Tony_Henrich
    I read a lot about SSDs and I am interested in them for server use. My biggest concern is their reliability. A lot of writes shortens their life span. I can mitigate this problem if I can run some kind of diagnostics on a regular basis on the SSD or if the SSD can automatically warn the OS that its reliability is reaching a critical level. Think of this as S.M.A.R.T or software like SpinRite for SSDs. Does anything I mentioned exist now? Which kind/brand of SSD does this? I don't mind swapping out a tired SSD for a newer one once a while. I am pretty sure that SSDs life is calculated in years and not in few months? For me, the improved performance will pay for the SSD over and over. I am planning to use plenty of RAM as well.

    Read the article

  • make a folder/partition on one computer appear as a mass storage device to another?

    - by user137560
    Is there anyway to make a folder or a partition on a computer (Linux or Windows) act like a mass storage device to other computers or devices when connected with a Male-Male USB cable? For example, I have a Windows 7 computer with 2 partitions, C and D. I would then connect that computer to another computer or a Smart TV using a Male-Male USB cable, and the other computer or device recognizes a folder/partition on current computer as a mass storage device. Is this possible? If not, is there any USB switch that can connect an external hard drive or flash drive to both a computer and TV without the need to manually switch them? (I know about some USB switches, but they only support automatic switching with some certain types of printers, not with mass storage)

    Read the article

< Previous Page | 236 237 238 239 240 241 242 243 244 245 246 247  | Next Page >