  • Repair Lacie 2Big Network 2

    - by Donier
    hi i buy from you Lacie 2big network 2 I was have problem with drive 2 "missed" then i try format HDD to mac os journal end RAW Now i can't connect to the device from network asistant please hep me I can't connect to Doshboard and i can't connect from USB on Lacie 2 big network 2device. I can connect to HDD from Lacie 2big network 2. how create lacie doshbaoard boot on HDD device. i format disks because one of HDD is work not correctly... in the Dashboard RAID menu disk 2 missed.... Thank you i wiil wait your answer....

    Read the article

  • lightweight access point?

    - by Joelio
    Im moving from an all in one to a router + access point. In doing googling and reasearch and talking to friends I ended up with router - cisco rv016 wifi access point - airnet 1142 lightweight access point. (lap1142n) In trying to set all this up and reading I think I bought the wrong access point. It seems I need a wireless controller? Can someone confirm that I should not have bought the lightweight one?

    Read the article

  • Joining Windows 7 Professional to a Windows Server 2003 R2 x64 domain fails.

    - by Vinko Vrsalovic
    I have a windows 7 professional (spanish) laptop trying to join a Windows Server 2003 (english) domain. It detect correctly the SRV record, finding the proper domain controller, but then the join fails with the error message (snippet, because the error is in spanish) An Active Directory Domain Controller for This Domain Could Not be Contacted The DNS is correctly set, and client can ping by name and IP the server, the server can ping the client by IP. I've tested with the FW down to no avail. A host of other XP Pro clients are connected to the domain. I've restarted Net Logon and checked that Windows Time is up. Also the times are in sync between the server and the client. I'll put below diagnostics output. I'm wondering if there's anything special to be done on either the server or the client to have a Win 7 Pro join a 2k3 R2 domain. The following diagnostic information follows: netdiag /q for the DC dcdiag on the DC ipconfig /all on the Win 7 client netdiag /q on the DC: .................................. Computer Name: HI-X2 DNS Host Name: hi-x2.hi.local System info : Microsoft Windows Server 2003 R2 (Build 3790) Processor : EM64T Family 6 Model 23 Stepping 10, GenuineIntel List of installed hotfixes : KB923561 KB924667-v2 KB925398_WMP64 KB925902 KB926122 KB927891 KB929123 KB930178 KB932168 KB936357 KB938127 KB941569 KB942830 KB942831 KB943055 KB943460 KB944338-v2 KB944653 KB945553 KB946026 KB948496 KB950760 KB950762 KB950974 KB951066 KB951748 KB952004 KB952069 KB952954 KB954155 KB954550-v7 KB955069 KB955759 KB956572 KB956802 KB956803 KB956844 KB958469 KB958644 KB958869 KB959426 KB960225 KB960803 KB960859 KB961063 KB961118 KB961501 KB967715 KB967723 KB968389 KB968816 KB969059 KB969947 KB970238 KB970430 KB970483 KB971032 KB971468 KB971657 KB971737 KB971961 KB971961-IE8 KB972270 KB973037 KB973354 KB973507 KB973540 KB973687 KB973815 KB973825 KB973869 KB973904 KB973917-v2 KB974112 KB974318 KB974392 KB974571 KB975025 KB975467 KB975560 KB975713 KB976662-IE8 KB977290 KB977816 KB977914 KB978037 KB978262 KB978338 KB978542 KB978601 KB978706 KB979306 KB979309 KB979683 KB980182 KB980182-IE8 KB980232 KB980302-IE8 KB981332-IE8 KB981350 Q147222 Per interface results: Adapter : Local Area Connection Host Name. . . . . . . . . : hi-x2.hi.local IP Address . . . . . . . . : 10.0.1.199 Subnet Mask. . . . . . . . : 255.0.0.0 Default Gateway. . . . . . : 10.0.1.1 Dns Servers. . . . . . . . : 10.0.1.199 WINS service test. . . . . : Skipped Global results: [WARNING] You don't have a single interface with the 'WorkStation Service', 'Messenger Service', 'WINS' names defined. DNS test . . . . . . . . . . . . . : Passed PASS - All the DNS entries for DC are registered on DNS server '10.0.1.199'. IP Security test . . . . . . . . . : Skipped The command completed successfully dcdiag on the DC: Domain Controller Diagnosis Performing initial setup: Done gathering initial info. Doing initial required tests Testing server: Default-First-Site-Name\HI-X2 Starting test: Connectivity ......................... HI-X2 passed test Connectivity Doing primary tests Testing server: Default-First-Site-Name\HI-X2 Starting test: Replications ......................... HI-X2 passed test Replications Starting test: NCSecDesc ......................... HI-X2 passed test NCSecDesc Starting test: NetLogons ......................... HI-X2 passed test NetLogons Starting test: Advertising ......................... HI-X2 passed test Advertising Starting test: KnowsOfRoleHolders ......................... HI-X2 passed test KnowsOfRoleHolders Starting test: RidManager ......................... HI-X2 passed test RidManager Starting test: MachineAccount ......................... HI-X2 passed test MachineAccount Starting test: Services ......................... HI-X2 passed test Services Starting test: ObjectsReplicated ......................... HI-X2 passed test ObjectsReplicated Starting test: frssysvol ......................... HI-X2 passed test frssysvol Starting test: frsevent ......................... HI-X2 passed test frsevent Starting test: kccevent ......................... HI-X2 passed test kccevent Starting test: systemlog ......................... HI-X2 passed test systemlog Starting test: VerifyReferences ......................... HI-X2 passed test VerifyReferences Running partition tests on : ForestDnsZones Starting test: CrossRefValidation ......................... ForestDnsZones passed test CrossRefValidation Starting test: CheckSDRefDom ......................... ForestDnsZones passed test CheckSDRefDom Running partition tests on : DomainDnsZones Starting test: CrossRefValidation ......................... DomainDnsZones passed test CrossRefValidation Starting test: CheckSDRefDom ......................... DomainDnsZones passed test CheckSDRefDom Running partition tests on : Schema Starting test: CrossRefValidation ......................... Schema passed test CrossRefValidation Starting test: CheckSDRefDom ......................... Schema passed test CheckSDRefDom Running partition tests on : Configuration Starting test: CrossRefValidation ......................... Configuration passed test CrossRefValidation Starting test: CheckSDRefDom ......................... Configuration passed test CheckSDRefDom Running partition tests on : hi Starting test: CrossRefValidation ......................... hi passed test CrossRefValidation Starting test: CheckSDRefDom ......................... hi passed test CheckSDRefDom Running enterprise tests on : hi.local Starting test: Intersite ......................... hi.local passed test Intersite Starting test: FsmoCheck ......................... hi.local passed test FsmoCheck ipconfig /all on the Windows 7 client: Configuraci¢n IP de Windows Nombre de host. . . . . . . . . : hi-p6 Sufijo DNS principal . . . . . : Tipo de nodo. . . . . . . . . . : h¡brido Enrutamiento IP habilitado. . . : no Proxy WINS habilitado . . . . . : no Adaptador de LAN inal mbrica Conexi¢n de red inal mbrica: Sufijo DNS espec¡fico para la conexi¢n. . : Descripci¢n . . . . . . . . . . . . . . . : Intel(R) WiFi Link 5100 AGN Direcci¢n f¡sica. . . . . . . . . . . . . : 00-22-FB-63-47-A0 DHCP habilitado . . . . . . . . . . . . . : no Configuraci¢n autom tica habilitada . . . : s¡ Direcci¢n IPv4. . . . . . . . . . . . . . : 10.0.1.42(Preferido) M scara de subred . . . . . . . . . . . . : 255.255.255.0 Puerta de enlace predeterminada . . . . . : 10.0.1.1 Servidores DNS. . . . . . . . . . . . . . : 10.0.1.199 NetBIOS sobre TCP/IP. . . . . . . . . . . : habilitado Adaptador de Ethernet Conexi¢n de  rea local: Estado de los medios. . . . . . . . . . . : medios desconectados Sufijo DNS espec¡fico para la conexi¢n. . : Descripci¢n . . . . . . . . . . . . . . . : Realtek PCIe GBE Family Controller Direcci¢n f¡sica. . . . . . . . . . . . . : 00-1E-33-1F-35-B1 DHCP habilitado . . . . . . . . . . . . . : s¡ Configuraci¢n autom tica habilitada . . . : s¡ Adaptador de t£nel isatap.{8926581E-09AC-4123-906B-DA6386AD2D60}: Estado de los medios. . . . . . . . . . . : medios desconectados Sufijo DNS espec¡fico para la conexi¢n. . : Descripci¢n . . . . . . . . . . . . . . . : Adaptador ISATAP de Microsoft Direcci¢n f¡sica. . . . . . . . . . . . . : 00-00-00-00-00-00-00-E0 DHCP habilitado . . . . . . . . . . . . . : no Configuraci¢n autom tica habilitada . . . : s¡ Adaptador de t£nel Teredo Tunneling Pseudo-Interface: Sufijo DNS espec¡fico para la conexi¢n. . : Descripci¢n . . . . . . . . . . . . . . . : Teredo Tunneling Pseudo-Interface Direcci¢n f¡sica. . . . . . . . . . . . . : 00-00-00-00-00-00-00-E0 DHCP habilitado . . . . . . . . . . . . . : no Configuraci¢n autom tica habilitada . . . : s¡ Direcci¢n IPv6 . . . . . . . . . . : 2001:0:5ef5:73ba:1cec:3883:f5ff:fed5(Preferido) V¡nculo: direcci¢n IPv6 local. . . : fe80::1cec:3883:f5ff:fed5%13(Preferido) Puerta de enlace predeterminada . . . . . : :: NetBIOS sobre TCP/IP. . . . . . . . . . . : deshabilitado

    Read the article

  • Motherboard rejects identical hard drive, one works the other doesn't

    - by Payson Welch
    I have an interesting situation. I have a Dell XS23-SB server that has four blades in it. The blades use Supermicro X7DWT motherboards, and interface with the sata drives through a backplane. I took two identical drives from a raid 0 enclosure that came from the factory (GDrive), one works on all four servers, the other does not. I verified that they both work by plugging them into a hard drive cradle. This behavior can be repeated with other drives, some drives work and some don't. However when i test them, they ALL work on my PC. What could cause this?

    Read the article

  • Sorting out mSSD acceleration on a Acer M3-581TG

    - by PhonicUK
    I recently purchased a Acer Timeline M3 Ultra, it ships with a 500GB HDD and a 20GB mSSD to use as a cache. First thing I did when I got it was format the drives and install a clean OS (on the HDD, the mSSD has nothing on it) - but now I can't figure out how everything needs to be configured in order to use the mSSD as a cache, it just looks like a standard storage drive. I've poked around in the BIOS and there is a SATA mode setting, but it only has one option (AHCI), most of the documentation I've seen on the subject says that the SATA controller needs to be in RAID mode otherwise 'Acceleration' isn't visible in the Intel SRT menu (which for me, it isn't) I've seen a few things that suggest I just need the correct partition layout, I tried this using fdisk from a Linux LiveCD but got nowhere. Any ideas? The laptop shipped with no recovery media so I'm marginally stumped. I don't have any issue with reformatting again if required.

    Read the article

  • windows-2003 server SCSI driver problem

    - by Vicky
    I have a problem in Adaptec 160m SCSI card connected to DELL Power Edge server, that it is often stops communicating. In windows system error I am able to see an error pointing to the SCSI driver continuously. The error says: The driver detected a controller error on \Device\Scsi\adpu160m4. For more information, see Help and Support Center at http://go.microsoft.com/fwlink/events.asp. Can anyone suggest me what to do to solve it?

    Read the article

  • Concerns about a Dedicated (Windows Server 2008) + DDoS

    - by TheKillerDev
    I am have today a dedicated server with these specs: Intel Core i5 750, 2x120GB (ssd + raid), Windows Server 2008 Web, 200Mbps Network, 24 Gb DD3 And I would like to know what are the best thing I can do to prevent a DDoS Attack, since I know this will be a real threat by the importance of the files that will be archived in it. Today I have apache listening port 80 and RDC listening port 3389. But the security is beeing made only by Windows Firewall. So, any thoughts on what would be good to prevent from DDoS attacks?

    Read the article

  • What disk setup is needed / best practice for hypervisor-only servers?

    - by Luke404
    Planning to buy some servers to run an hypervisor (Citrix XenServer or VMware vSphere, still have to decide between the two) we'd like to boot off the local redundant SD card module offered by various vendors (eg. Dell, HP, etc...). The actual VMs will run from an existing iSCSI SAN (which, by the way, can't support booting the servers directly off the SAN). What are the reasons, if any, to choose completely diskless servers VS having some local storage? And what would be the guidelines to choose that local storage? (number of spindles, raid level, etc)

    Read the article

  • Deleting Temporary Internet Files through Group Policy

    - by Kami
    I have a domain controller running on Windows 2008 Server R2 and users login to application servers on which Windows 2003 Server SP2 is installed. I have applied a Group Policy to clean temporary internet files on exit i.e to delete all temporary internet files when users close the browser. But the group policy doesn't seem to work as user profile size keeps on increasing and the major space is occupied by temporary internet files therefore increasing the disk usage. How can i enforce automatic deletion of temporary internet files?

    Read the article

  • What is normal SCSI error handling process (scsi_eh_3) CPU time usage?

    - by Kris Jordan
    Last week I got setup with a new dedicated server that is running 4x SCSI drives in RAID 10 on CentOS. The machine is pretty lightly loaded at the moment and has been running for 8 days. The process 'scsi_eh_3' has a CPU time of 13:09.67 in top. This is 3x the next closest CPU time of 4:03.93 for mysqld. Is it normal for the scsi error handling process to use this much CPU time? (Seems like it goes to 0.3% usage ever 5 seconds.) Could this be an indicator that one or more of the drives is having issues?

    Read the article

  • Shared storage solution for our sql server backups

    - by Gokhan
    We have 3 clustered sql servers. We have 5+ multi terrabyte databases and their backup files (compressed using quest litespeed) are hitting over 600gb each, We are required to keep at least a week or two weeks (if we can) of weekly full backups and then 6 days differential backups, and a week or 2 weeks worth of log backups local. We are currently limited to 2TB volumes from our san team, we can have multiple volumes but they are expensive ($200 per raw TB per month) and having to deal with many backup volumes instead of a single big volume is difficult. I think if we could have a shared network storage of 20TB+ raid 10 or so for all our servers for keeping the backups and another department will copy them to tape from the network storage and delete files according to the retention period would be good, if this box would be a build in operating system (even unix a complete file storage system) that would be good. What do you guys think, does this make sense to you, is there any manufacturer that sells a storage product like that which that work in a clustered environment? Thank you

    Read the article

  • System failure - need diagnostic recommendation

    - by Ladislav Mrnka
    I have big problem with my computer. Configuration is: Intel i7 + 6x2GB OCZ DDR3 Motheboard: Asus P6T Deluxe V2, HDD controller configured to AHCI Main drive: OCZ Vertex 2 (SSD) - contains all installed programs and system Second drive: Samsung SpinPoint - contains User profiles, ProgramData, virtual machines and databases Third drive: Samsung SpinPoint - data drive + backups OS: Windows 7 Ultimate x64 I have never had any problem with this computer until now. During weekend my computer completely crashed without any reason. Each time I tried to boot to Windows I got BSOD with message BAD_SYSTEM_CONFIG_INFO and automatic restart (I didn't install any new SW or HW). But after restart main OCZ drive was disconnected (not detected by BIOS). When I turned off and on computer, the drive was again connected. It also happend every single time I tried to repair installation somehow. It ended with some error and after restart drive was disconnected. The only thing which worked was format + fresh install. After installing almost everything I wanted to install Visual Studio 2010 Ultimate (complete installation without SQL Server Express). During installation of VS itself I always get BSOD - it is too fast so I'm not able to read description. After restart it searches for all disk drives for really long time and sometimes it changes boot drive so the system is not able to start - Bootmgr not found. After reconfiguring BIOS the system starts. There is no event describing the failure in Event viewer. Installing VS 2010 is absolutely necessary for me. I need help with diagnostic. I need to find where is the problem - I expect that the problem is in OCZ drive or in HDD controller on motherboard but I don't know how to find it. All components still have valid warranty. Can you recommend me some approach or tools to find the problem? Edit: I'm still looking for source of the problem. New information is that Windows are not able to perform check disk (Chkdsk) on the SSD system drive. After restarting it always starts checking drive and in part where files are checked it fails with BSOD - BAD_SYSTEM_CONFIG_INFO. After next restart and skipping check disk tests the system runs.

    Read the article

  • Brocade 200E Switch - Fibre Channel

    - by Arthor
    What I have: Fujitsu-Siemens PRIMERGY BX600 Brocade 200E (16 port, 4gbit fibre). My question: Imagine a QNAP with a fiber 10GBIT card connected to the Brocade 200E (16 port, 4gbit fibre). Would this work; would the card drop down to 4GBIT? Are 10GBIT fiber cards backwards completable. Update. I have the specs of my server now.... Fujitsu-Siemens PRIMERGY BX600 S3 Blade Ecosystem Blade Chassis comprising; 2 x A3C40073243 Blade Management modules 2 x A3C40089238 GBE Switch Blade SB9F 30/12 2 x A3C40085736 4Gb 10 port pass through blades 1 x A3C40083767 Digital KVM Modules 2 x A3C40073245 Fan enclosures + cooling fans 4 x A3C40073262 Power Supplies My Goals and Objectives To have a blade system in place for 8 blades for video rendering, the other 2 for database and scripts etc The system will be built on VMWARE ESXi 5 Use ISCSI on the QNAP to support HA and vmotion if needed Users to access the qnap for video editing QANAP has 12 drive (2 x (6 HDD in RAID 10)

    Read the article

  • Shared storage for web cluster

    - by user52475
    Hi all! Have a big question about shared/clustered/distributed file system for storage. It will shared storage for shared web hosting (web files + maildir) and OpenVZ containers storage . Have any one working example of such system? The options are: Lustre GFS1/GFS2 - GFS2 - as I understand is EXPERIMENTAL... NFS This 3 systems which I consider for shared storage. Now I have storage with HW RAID 10 - 1TB. NFS - As I know there will be problem with locking? GFS/Lustre - problems when there will be a lot of small files , what is typical for hosting environment and problems with maildir.

    Read the article

  • In AD how to get groups the workstation is a member of from the workstation itself?

    - by David
    If I'm at the domain controller (in the Active Directory) to find out what groups the "XPSP3-A" workstation is a member of, I do: dsquery computer "CN=XPSP3-A,CN=Computers,DC=pvk,DC=local" -name XPSP3-A | dsget computer -memberof and receive the following: "CN=Sec Group 001,OU=OU1,DC=pvk,DC=local" "CN=Domain Computers,CN=Users,DC=pvk,DC=local" But how to do the same from the "XPSP3-A" workstation?

    Read the article

  • IBM Server searching for secondary server

    - by user1241438
    I just bought the following server IBM System x3950 Server, 4 x 3.0GHz Dual Core, 32GB, 6 x 73.4GB 10K SAS RAID, 256MB BBWC, 2x Power, CD-RW/DVD When i boot it up, it says "Searching for secondary server" and hangs their for almost 10 mins. After 10 mins, it says timeout on searching chassis 2. But after this it proceed to boot the OS properly. But my frustration, i need to wait for almost 15 mins to boot everytime. How do i prevent this error message.

    Read the article

  • Is there still a place for tape storage?

    - by Jon Ericson
    We've backed up our data on LTO tapes for years and it's a real comfort to know we have everything on tape. A sister project and one of our data providers have both moved to 100% disk storage because the cost of disk has dropped so much. When we propose systems to potential customers these days we tend to downplay or not mention our use of tape systems for data storage since it might seem outdated. I feel more comfortable with having data saved in two separate formats: disks and tape. In addition, once data is securely written to tape, I feel (perhaps naively) that it's been permanently saved. Not having to rely on a RAID controller to be able to read back data is another plus for me. Do you see a place for tape backup these days?

    Read the article

  • What would cause the Graphic Equalizer in Windows Media Player 10 to be disabled/not available?

    - by creamcheese
    On XP, Windows Media Player 10 contains a Graphic Equalizer but I can't find any way to activate it. Could this be a codec issue or a hardware issue? I'm also not getting any sound at all from this computer but there are no apparent hardware device issues marked in Device Manager, nothing is muted, all volume levels are turned fully up (Windows Media Player and the Windows Volume Controller). Stumped!

    Read the article

  • Time until Members added to Group Policy is Replicated

    - by Kyle Brandt
    If I have a group policy, and add a group/user/machine etc to that group policy, how long is it until all domain controllers have that change in effect? This is a Windows 2003 Domain set up with controllers at different geographic locations (Each with a different L3 network). I realize it probably depends, but how do I figure out how long it generally takes for my given setup? Also, is there an event I can check to see if it has a reached a particular domain controller?

    Read the article

  • Ubuntu hardware wireless switch has no effect after suspend and 13.10 upgrade

    - by blaineh
    I'm posting this on SU after it stalled on askubuntu. I hope someone here can help! If you'd prefer to answer on AU itself, here's the link: http://askubuntu.com/questions/365177/hardware-wireless-switch-has-no-effect-after-suspend-and-13-10-upgrade Wireless works fine after a reboot, but after a suspend the hardware switch (for my laptop this is f12) has no effect on the wireless, it is just permanently off, and shows that it is with a red LED. My rfkill list all reads: 0: phy0: Wireless LAN Soft blocked: no Hard blocked: yes 1: hp-wifi: Wireless LAN Soft blocked: no Hard blocked: yes Any combination with rfkill <un>block wifi doesn't work, although one time first blocking then unblocking actually turned it on again. sudo lshw -C network reads: *-network DISABLED description: Wireless interface product: AR9285 Wireless Network Adapter (PCI-Express) vendor: Qualcomm Atheros physical id: 0 bus info: pci@0000:02:00.0 logical name: wlan0 version: 01 serial: 78:e4:00:65:2e:3f width: 64 bits clock: 33MHz capabilities: pm msi pciexpress bus_master cap_list ethernet physical wireless configuration: broadcast=yes driver=ath9k driverversion=3.11.0-12-generic firmware=N/A latency=0 link=no multicast=yes wireless=IEEE 802.11bgn resources: irq:17 memory:90100000-9010ffff *-network DISABLED description: Ethernet interface product: RTL8101E/RTL8102E PCI Express Fast Ethernet controller vendor: Realtek Semiconductor Co., Ltd. physical id: 0 bus info: pci@0000:03:00.0 logical name: eth0 version: 02 serial: c8:0a:a9:89:b4:30 size: 10Mbit/s capacity: 100Mbit/s width: 64 bits clock: 33MHz capabilities: pm msi pciexpress msix vpd bus_master cap_list rom ethernet physical tp mii 10bt 10bt-fd 100bt 100bt-fd autonegotiation configuration: autonegotiation=on broadcast=yes driver=r8169 driverversion=2.3LK-NAPI duplex=half latency=0 link=no multicast=yes port=MII speed=10Mbit/s resources: irq:42 ioport:2000(size=256) memory:90010000-90010fff memory:90000000-9000ffff memory:90020000-9002ffff Also, adding a /etc/pm/sleep.d/brcm.sh file as recommended here simply prevents the laptop from suspending at all, which of course is no good. This question has an answer urging to install the original driver, but it wasn't an "accepted answer" so I'd rather not take a chance on it. Also I'll admit I'm a bit lost on that and would like help doing so with the specific information I've given. I would be happy to provide more information, so long as you're willing to help me find it for you! This is a very annoying bug. I have a Compaq Presario CQ62. Edit. Output of lspci | grep Network: 02:00.0 Network controller: Qualcomm Atheros AR9285 Wireless Network Adapter (PCI-Express) (rev 01) Edit. This morning, I had had the laptop suspended all night, and then when I tried to awake it, it simply wouldn't. It would try, and then it would sleep again (I guess it felt a little bit like me! </badjoke>). Is it possible these problems are related? Edit. I don't have enough reputation on SU proper to post links to pastebins and other questions I've tried, so I'm putting them in comments, and of course they're available in the original question.

    Read the article

  • Disable password complexity rule in Active Directory

    - by Dan Revell
    Where do I go to disable the password complexity policy for the domain. I've logged onto the domain controller (Windows Server 2008) and found the option in local policies which is of course locked from any changes. However I can't find the same sort of policies in the group policy manager. Which nodes do I have to expand out to find it?

    Read the article

  • Cloning a linux system from sdx to cciss

    - by churnd
    I have an HP ML 310 server running CentOS Linux 5.5. I'm buying a RAID card (LSI 9260-8i) to set up a mirrored OS drive. Right now, the boot drive is set up with GRUB installed on the MBR of /dev/sda & has a 100MB /boot partition for /dev/sda1, then the rest is configured in LVM with a 20GB with a 20GB VG for the root partition & ~80GB VG for home. The new disk sizes will also be slightly larger as well. What is the best way to clone the boot drive to the new CCISS device?

    Read the article

  • Red Hat 5.4 slow processing

    - by yucefrizk
    I'm running Red Hat Linux 5.4 on HP DL580 server with 16 processors and 64 GB of RAM. I'm connecting to the server remotely through SSH. after entering the password, it takes time to return the command line, if I click ctrl+c during this time, I'll have the command line prompt but not the correct bash prompt (I have to run bash to pass to my correct prompt). I tried to install Apache on the server, ./configure took 4 hours to finish instead of 1 or two minutes, Oracle installation same behavior. Server Disks are mirrored using RAID controller. any idea what could be the reason of this slowness?

    Read the article

  • How to audit a specific folder in Windows Server 2003?

    - by saint
    We have had several cases of file deletion in one of our windows file servers. Server is also a domain controller. Unfortunately we kept the auditing disabled completely due it being such a resource hog. So I was wondering If there is a way to audit a specific folder for a specific security group, for just file and folder deletions within the specified folder. Also is there a recommended third party application for auditing or monitoring. Many Thanks.

    Read the article