Search Results

Search found 25754 results on 1031 pages for 'serial number'.

Page 25/1031 | < Previous Page | 21 22 23 24 25 26 27 28 29 30 31 32  | Next Page >

  • What are the licence restrictions for the RxTx Library

    - by Azder
    I want to make an Application that uses RxTx version 2.2pre2 to work with Serial Ports. What are the Licence restrictions, since it is an "LGPL v 2.1 + Linking Over Controlled Interface" licenced library if I don't use the Sun's javax.comm.* interface, but the RxTx's own gnu.io.* when importing into Java Files?

    Read the article

  • Is 0x9B (155decimal) a special control character? Why is it missing from ascii tables?

    - by Chris
    Hi, I'm working on an embedded system, and i'm having dramas getting it to send a certain chunk of data across the serial port. I narrowed it down and found that if a 0x9B is present in the message, it corrupts the message. So i then look up 0x9b (155) on http://www.asciitable.com/, and it's missing! Isn't that a bizarre coincidence! Any ideas, is this a special character or something?

    Read the article

  • What is wrong with this attempt of sending a break-signal?

    - by Jook
    I have quite a headache about this seemingly easy task: send a break signal to my device, like the wxTerm (or any similar Terminal application) does. This signal has to be 125ms long, according to my tests and the devices specification. It should result in a specific response, but what I get is a longer response than expected, and the transmitted date is false. e.g.: what it should respond 08 00 81 00 00 01 07 00 what it does respond 08 01 0A 0C 10 40 40 07 00 7F What really boggles me is, that after I have used wxTerm to look at my available com-ports (without connecting or sending anything), my code starts to work! I can send then as many breaks as I like, I get my response right from then on. I have to reset my PC in order to try it again. What the heck is going on here?! Here is my code for a reset through a break-signal: minicom_client(boost::asio::io_service& io_service, unsigned int baud, const string& device) : active_(true), io_service_(io_service), serialPort(io_service, device) { if (!serialPort.is_open()) { cerr << "Failed to open serial port\n"; return; } boost::asio::serial_port_base::flow_control FLOW( boost::asio::serial_port_base::flow_control::hardware ); boost::asio::serial_port_base::baud_rate baud_option(baud); serialPort.set_option(FLOW); serialPort.set_option(baud_option); read_start(); std::cout << SetCommBreak(serialPort.native_handle()) << std::endl; std::cout << GetLastError() << std::endl; boost::posix_time::ptime mst1 = boost::posix_time::microsec_clock::local_time(); boost::this_thread::sleep(boost::posix_time::millisec(125)); boost::posix_time::ptime mst2 = boost::posix_time::microsec_clock::local_time(); std::cout << ClearCommBreak(serialPort.native_handle()) << std::endl; std::cout << GetLastError() << std::endl; boost::posix_time::time_duration msdiff = mst2 - mst1; std::cout << msdiff.total_milliseconds() << std::endl; } Edit: It was only necessary to look at the combo-box selection of com-ports of wxTerm - no active connection was needed to be established in order to make my code work. I am guessing, that there is some sort of initialisation missing, which is done, when wxTerm is creating the list for the serial-port combo-box.

    Read the article

  • Can we manage incoming call number landing on asterisk?

    - by user194469
    I am using Asterisk 1.4.2 in two different machine. I have configured some extensions in asterisk. When any caller, dial my extension number with local number then if I see asterisk console (asterisk -r) then incoming number is starting with 0, but if caller dial same extension number using STD number then in asterisk console (asterisk -r), incoming number is staring with 0091 (here 91 is country code). Could I change this setting or is there any standard for asterisk for local, STD or ISD number?

    Read the article

  • Understanding EDI 997.

    - by VishnuTiwariBlog
    Hi Guys, This is for the EDI starter. Below is the complete detail of EDI 997 segment and element details. 997 Functional Acknowledgment Transaction Layout: No. Seg ID Name Description Example M/O 010 ST Transaction Set Header To indicate the start of a transaction set and to assign a control number ST*997*382823~   M ST01   Code uniquely identifying a Transaction Set   M ST02   Identifying control number that must be unique within the transaction set functional group assigned by the originator for a transaction set   M 020 AK1 Functional Group Response Header To start acknowledgment of a functional group AK1*QM*2459823 M        AK101   Code identifying a group of application related transaction sets IN Invoice Information (810) SH Ship Notice/Manifest (856)     AK102   Assigned number originated and maintained by the sender     030 AK2 Transaction Set Response Header To start acknowledgment of a single transaction set AK2*856*001 M AK201   Code uniquely identifying a Transaction Set 810 Invoice 856 Ship Notice/Manifest   M AK202   Identifying control number that must be unique within the transaction set functional group assigned by the originator for a transaction set   M 040 AK3 Data Segment Note To report errors in a data segment and identify the location of the data segment AK3*TD3*9 O AK301 Segment ID Code Code defining the segment ID of the data segment in error (See Appendix A - Number 77)     AK302 Segment Position in Transaction Set The numerical count position of this data segment from the start of the transaction set: the transaction set header is count position 1     050 AK4 Data Element Note To report errors in a data element or composite data structure and identify the location of the data element AK4*2**2 O AK401 Position in Segment Code indicating the relative position of a simple data element, or the relative position of a composite data structure combined with the relative position of the component data element within the composite data structure, in error; the count starts with 1 for the simple data element or composite data structure immediately following the segment ID     AK402 Element Position in Segment This is used to indicate the relative position of a simple data element, or the relative position of a composite data structure with the relative position of the component within the composite data structure, in error; in the data segment the count starts with 1 for the simple data element or composite data structure immediately following the segment ID     AK403 Data Element Syntax Error Code Code indicating the error found after syntax edits of a data element 1 Mandatory Data Element Missing 2 Conditional Required Data Element Missing 3 Too Many Data Elements 4 Data Element Too Short 5 Data Element Too Long 6 Invalid Character in Data Element 7 Invalid Code Value 8 Invalid Date 9 Invalid Time 10 Exclusion Condition Violated     AK404 Copy of Bad Data Element This is a copy of the data element in error     060 AK5 AK5 Transaction Set Response Trailer To acknowledge acceptance or rejection and report errors in a transaction set AK5*A~ AK5*R*5~ M AK501 Transaction Set Acknowledgment Code Code indicating accept or reject condition based on the syntax editing of the transaction set A Accepted E Accepted But Errors Were Noted R Rejected     AK502 Transaction Set Syntax Error Code Code indicating error found based on the syntax editing of a transaction set 1 Transaction Set Not Supported 2 Transaction Set Trailer Missing 3 Transaction Set Control Number in Header and Trailer Do Not Match 4 Number of Included Segments Does Not Match Actual Count 5 One or More Segments in Error 6 Missing or Invalid Transaction Set Identifier 7 Missing or Invalid Transaction Set Control Number     070 AK9 Functional Group Response Trailer To acknowledge acceptance or rejection of a functional group and report the number of included transaction sets from the original trailer, the accepted sets, and the received sets in this functional group AK9*A*1*1*1~ AK9*R*1*1*0~ M AK901 Functional Group Acknowledge Code Code indicating accept or reject condition based on the syntax editing of the functional group A Accepted E Accepted, But Errors Were Noted. R Rejected     AK902 Number of Transaction Sets Included Total number of transaction sets included in the functional group or interchange (transmission) group terminated by the trailer containing this data element     AK903 Number of Received Transaction Sets Number of Transaction Sets received     AK904 Number of Accepted Transaction Sets Number of accepted Transaction Sets in a Functional Group     AK905 Functional Group Syntax Error Code Code indicating error found based on the syntax editing of the functional group header and/or trailer 1 Functional Group Not Supported 2 Functional Group Version Not Supported 3 Functional Group Trailer Missing 4 Group Control Number in the Functional Group Header and Trailer Do Not Agree 5 Number of Included Transaction Sets Does Not Match Actual Count 6 Group Control Number Violates Syntax     080 SE Transaction Set Trailer To indicate the end of the transaction set and provide the count of the transmitted segments (including the beginning (ST) and ending (SE) segments) SE*9*223~ M SE01 Number of Included Segments Total number of segments included in a transaction set including ST and SE segments     SE02 Transaction Set Control Number Identifying control number that must be unique within the transaction set functional group assigned by the originator for a transaction set

    Read the article

  • Understanding EDI 997

    - by VishnuTiwariBlog
    Hi Guys, This is for the EDI starter. Below is the complete detail of EDI 997 segment and element details. 997 Functional Acknowledgment Transaction Layout:   No. Seg ID Name Description Example M/O 010 ST Transaction Set Header To indicate the start of a transaction set and to assign a control number ST*997*382823~   M ST01   Code uniquely identifying a Transaction Set   M ST02   Identifying control number that must be unique within the transaction set functional group assigned by the originator for a transaction set   M 020 AK1 Functional Group Response Header To start acknowledgment of a functional group AK1*QM*2459823 M        AK101   Code identifying a group of application related transaction sets IN Invoice Information (810) SH Ship Notice/Manifest (856)     AK102   Assigned number originated and maintained by the sender     030 AK2 Transaction Set Response Header To start acknowledgment of a single transaction set AK2*856*001 M AK201   Code uniquely identifying a Transaction Set 810 Invoice 856 Ship Notice/Manifest   M AK202   Identifying control number that must be unique within the transaction set functional group assigned by the originator for a transaction set   M 040 AK3 Data Segment Note To report errors in a data segment and identify the location of the data segment AK3*TD3*9 O AK301 Segment ID Code Code defining the segment ID of the data segment in error (See Appendix A - Number 77)     AK302 Segment Position in Transaction Set The numerical count position of this data segment from the start of the transaction set: the transaction set header is count position 1     050 AK4 Data Element Note To report errors in a data element or composite data structure and identify the location of the data element AK4*2**2 O AK401 Position in Segment Code indicating the relative position of a simple data element, or the relative position of a composite data structure combined with the relative position of the component data element within the composite data structure, in error; the count starts with 1 for the simple data element or composite data structure immediately following the segment ID     AK402 Element Position in Segment This is used to indicate the relative position of a simple data element, or the relative position of a composite data structure with the relative position of the component within the composite data structure, in error; in the data segment the count starts with 1 for the simple data element or composite data structure immediately following the segment ID     AK403 Data Element Syntax Error Code Code indicating the error found after syntax edits of a data element 1 Mandatory Data Element Missing 2 Conditional Required Data Element Missing 3 Too Many Data Elements 4 Data Element Too Short 5 Data Element Too Long 6 Invalid Character in Data Element 7 Invalid Code Value 8 Invalid Date 9 Invalid Time 10 Exclusion Condition Violated     AK404 Copy of Bad Data Element This is a copy of the data element in error     060 AK5 AK5 Transaction Set Response Trailer To acknowledge acceptance or rejection and report errors in a transaction set AK5*A~ AK5*R*5~ M AK501 Transaction Set Acknowledgment Code Code indicating accept or reject condition based on the syntax editing of the transaction set A Accepted E Accepted But Errors Were Noted R Rejected     AK502 Transaction Set Syntax Error Code Code indicating error found based on the syntax editing of a transaction set 1 Transaction Set Not Supported 2 Transaction Set Trailer Missing 3 Transaction Set Control Number in Header and Trailer Do Not Match 4 Number of Included Segments Does Not Match Actual Count 5 One or More Segments in Error 6 Missing or Invalid Transaction Set Identifier 7 Missing or Invalid Transaction Set Control Number     070 AK9 Functional Group Response Trailer To acknowledge acceptance or rejection of a functional group and report the number of included transaction sets from the original trailer, the accepted sets, and the received sets in this functional group AK9*A*1*1*1~ AK9*R*1*1*0~ M AK901 Functional Group Acknowledge Code Code indicating accept or reject condition based on the syntax editing of the functional group A Accepted E Accepted, But Errors Were Noted. R Rejected     AK902 Number of Transaction Sets Included Total number of transaction sets included in the functional group or interchange (transmission) group terminated by the trailer containing this data element     AK903 Number of Received Transaction Sets Number of Transaction Sets received     AK904 Number of Accepted Transaction Sets Number of accepted Transaction Sets in a Functional Group     AK905 Functional Group Syntax Error Code Code indicating error found based on the syntax editing of the functional group header and/or trailer 1 Functional Group Not Supported 2 Functional Group Version Not Supported 3 Functional Group Trailer Missing 4 Group Control Number in the Functional Group Header and Trailer Do Not Agree 5 Number of Included Transaction Sets Does Not Match Actual Count 6 Group Control Number Violates Syntax     080 SE Transaction Set Trailer To indicate the end of the transaction set and provide the count of the transmitted segments (including the beginning (ST) and ending (SE) segments) SE*9*223~ M SE01 Number of Included Segments Total number of segments included in a transaction set including ST and SE segments     SE02 Transaction Set Control Number Identifying control number that must be unique within the transaction set functional group assigned by the originator for a transaction set

    Read the article

  • Making a cracked or activated windows uncracked

    - by ugurcode
    I have a pc which has windows 7 license but I installed windows from an image i downloaded and it is already activated. for validating genuine microsoft, i need to entet my own product key but the necessary activation tools do not exist in my windows folder. What do? I googled stuff but because the keywords are too broad I couldn't find a useful tool DAZ doesn't work, activation button doesn't show up. When I enter my original key to Windows Anytime Upgrade, I get this error When I attempt using slmgr, I get this error I used sfc /scannow Now slmgr is existing, I entered slmgr.vbs -ipk XXXXX-XXXXX-XXXXX-XXXXX-XXXXX (replacing X es with the cd key) the operation successful. Now I have installed Microsoft Security essentials, which means the problem is solved. Main steps are here open cmd enter Enter "sfc /scannow" enter slmgr.vbs -ipk XXXXX-XXXXX-XXXXX-XXXXX-XXXXX Success

    Read the article

  • How do I use a Minitel terminal as a linux dumb terminal

    - by Pawz
    I recently purchased a US version of the Alcatel Minitel terminal. I think it's a 1B version. Pictures of it here: I tried connecting a null modem to the 25 pin port on the back and plugging it into a linux box running agetty but I couldn't get it to show any signs of being connected. I used Google Translate to translate this document into English: http://mirabellug.org/wikini/upload/Documentations_minitel.pdf As far as I can tell, you take it out of videotex mode by typing Fcnt-T A, then turn off local echo with Fcnt-T E, then set it to 4800 baud with Fcnt-P 4. I presume Fcnt refers to the "CTRL" key on my terminal. But I think I'm doing something wrong, because it doesn't look like it's recognising the keystrokes, because "Fcnt-T A" just prints the letter A to the screen, which is not what you'd expect a function key combo to do. Has anyone used these minitel terminals as a linux terminal, and if so, please can you share how to configure the minitel to run as a terminal ? Is the 25 pin plug even the correct port to use ? I read something online that indicated you're supposed to use the 5 pin DIN plug instead, is that right ? If so, what's the 25 pin plug for ? If I am supposed to use the DIN plug, does anyone know the pinouts so I can make a cable ?

    Read the article

  • What is the minimum delay between two consecutive RS232 frames?

    - by Lord Loh.
    I have been working on creating a UART on an FPGA. I can successfully transmit and receive single characters typed on PuTTY. However, when I set my FPGA to constantly write a large sequences of "A", sometimes I end up with a sequences of "@" or some other characters until I reset the FPGA a few times. I believe the UART on the computer looses track of the difference between the start bit and a zero. The delay between the two "A" is ~ 30us (measured with a logic analyzer) and the baud rate is 115200 8N1. Is there a minimum delay that must be maintained between two consecutive RS232 frames?

    Read the article

  • TCP > COM1 for receiving messages and displaying on POS display pole

    - by JakeTheSnake
    I currently have a Java Applet running on my web page that communicates to a display pole via COM1. However since the Java update I can no longer run self-signed Java Applets and I figure it would just be easier to send an AJAX request back to the server and have the server send a response to a TCP port on the computer...the computer would need a TCP COM virtual adapter. How do I install a virtual adapter to go from a TCP port to COM1? I've looked into com0com and that is just confusing as hell to me, and I don't see how to connect any ports to COM1. I've tried tcp2com but it doesn't seem to install the service in Windows 7 x64. I've tried com2tcp and the interface seems like it WOULD work (I haven't tested), but I don't want an app running on the desktop...it needs to be a service that runs in the background. So to summarize how it would work: Web page on comp1 sends AJAX request to server Server sends text response to comp1 on port 999 comp1 has virtual COM port listening on port 999, sends data to COM1 pole displays data

    Read the article

  • Sending a file to uCLinux

    - by Mike
    I have a board running uClinux, and I need to send a file to it, but I'm not sure how... I have a RS232 port, and Ethernet port with an IP address at my disposal, I can telnet to the board, but uCLinux doesn't have a built in FTP client. What sort of options do I have here for transferring files from my Windows 7 (or OpenSUSE) machine(s) to this board? EDIT I just found I have a TFTP server on it: # tftp BusyBox v0.60.5 (2012.07.09-14:05+0000) multi-call binary Usage: tftp [OPTION]... HOST [PORT] But I can't find any good information on how to use TFTP. And looking around google I'm seeing it's good for loading binary images, so I'm assume anything could be sent, but I'm not sure.

    Read the article

  • jQuery counter to count up to a target number

    - by Matt Huggins
    I'm trying to find out if anyone knows about an already existing jQuery plugin that will count up to a target number at a specified speed. For example, take a look at Google's number of MB of free storage on the Gmail homepage, under the heading that reads "Lots of space". It has a starting number in a <span> tag, and slowly counts upward every second. I'm looking for something similar, but I'd like to be able to specify: The start number The end number The amount of time it should take to get from start to end. A custom callback function that can execute when a counter is finished.

    Read the article

  • Fast permutation -> number -> permutation mapping algorithms

    - by ijw
    I have n elements. For the sake of an example, let's say, 7 elements, 1234567. I know there are 7! = 5040 permutations possible of these 7 elements. I want a fast algorithm comprising two functions: f(number) maps a number between 0 and 5039 to a unique permutation, and f'(permutation) maps the permutation back to the number that it was generated from. I don't care about the correspondence between number and permutation, providing each permutation has its own unique number. So, for instance, I might have functions where f(0) = '1234567' f'('1234567') = 0 The fastest algorithm that comes to mind is to enumerate all permutations and create a lookup table in both directions, so that, once the tables are created, f(0) would be O(1) and f('1234567') would be a lookup on a string. However, this is memory hungry, particularly when n becomes large. Can anyone propose another algorithm that would work quickly and without the memory disadvantage?

    Read the article

  • Code Golf: Phone Number to Words

    - by Nick Hodges
    Guidelines for code-golf on SO We've all seen phone numbers that are put into words: 1-800-BUY-MORE, etc. What is the shortest amount of code you can write that will produce all the possible combinations of words for a 7 digit US phone number. Input will be a seven digit integer (or string, if that is simpler), and assume that the input is properly formed. Output will be a list of seven character strings that For instance, the number 428-5246 would produce GATJAGM GATJAGN GATJAGO GATJAHM GATJAHN GATJAHO and so on..... Winning criteria will be code from any language with the fewest characters that produce every possible letter combination. Additional Notes: To make it more interesting, words can be formed only by using the letters on a North American Classic Key Pad phone with three letters per number as defined here.That means that Z and Q are excluded. For the number '1', put a space. For the number '0', put a hyphen '-' Bonus points awarded for recognizing output as real English words. Okay, not really. ;-)

    Read the article

  • How do I know if my serial adapter card is working?

    - by Ingram
    I just installed a 2 port serial adapter in my Ubuntu 10.10 system, then I tried following this tutorial that I used on my old system to connect to a cisco router (my old system had an onboard serial adapter, and the tutorial worked just fine). I can't get my system to connect to the cisco router, so I'm wondering if the card even works in Ubuntu. How can I tell if the card actually works with Ubuntu? #dmesg | grep tty [ 0.000000] console [tty0] enabled [ 0.358667] serial8250: ttyS0 at I/O 0x3f8 (irq = 4) is a 16550A [ 0.358994] 00:0c: ttyS0 at I/O 0x3f8 (irq = 4) is a 16550A [ 0.359128] ttyS1: detected caps 00000700 should be 00000100 [ 0.359132] 0000:03:00.0: ttyS1 at MMIO 0xfeafd000 (irq = 16) is a 16C950/954 [ 0.359191] ttyS2: detected caps 00000700 should be 00000100 [ 0.359195] 0000:03:00.0: ttyS2 at MMIO 0xfeafd200 (irq = 16) is a 16C950/954

    Read the article

  • How do I assign a number value to a non-numerical value in Excel

    - by Keyslinger
    Greetings I have an some survey responses with values like "VU" for "Very Unlikely" and "S" for Sometimes. Each survey response occupies a cell. For each cell containing a survey response, I want to fill another cell with a corresponding number. For example, for every cell containing "VU" I want to fill a corresponding cell with the number 1. How is this done?

    Read the article

  • Remove a file on linux using the inode number

    - by WebDevHobo
    If you create a file on UNIX/linux with special chars, like touch \"la*, you can't remove it with rm "la*. You have to use the inode number(you can if you add the \ before the name, I know, but you'd have to guess as a user that it was used in the file creation). I checked the manpage for rm, but there's no metion of the inode number. Doing rm inodenumber doesn't work either. What is the command for this?

    Read the article

  • Show the number of messages within a group in Outlook 2010

    - by Brendan
    In outlook 2010 I am unable to show the number of messages within a particular group. For example, I categorise my messages and then when I sort by category, there is no way to show the number of messages within that(those) category(ies). Previous versions of outlook would do this by default, but I am not finding the setting to do this in Outlook 2010. If it isn't possible, is there anything method to count those messages within a group/category easily?

    Read the article

  • Tomcat 6 going down after reaching its maximum number of threads

    - by user73628
    Our Tomcat 6.0.29 goes down after reaching its maximum number of Threads. I would really appreciate any help with it because it is a production server. Here is part of the catalina.log file: INFO: Maximum number of threads (600) created for connector with address null and port 80 Mar 8, 2011 11:19:37 AM org.apache.coyote.http11.Http11Protocol pause INFO: Pausing Coyote HTTP/1.1 on http-80 Mar 8, 2011 11:19:38 AM org.apache.catalina.core.StandardService stop INFO: Stopping service Catalina Mar 8, 2011 11:19:38 AM org.apache.catalina.core.StandardWrapper unload INFO: Waiting for 8 instance(s) to be deallocated

    Read the article

  • How to increase the maximum number of participants in Office Communicator conference

    - by Stephen Jennings
    We often want to make quick announcements to our group of 20 people using Office Communicator, so we highlight a group of contacts and start a new IM session. However, only a maximum of 10 people are able to join the conversation; after the maximum number of people join, all other invitees get the message: Cannot connect to the conference because it is full. Contact the conference leader for more information. Is there a way to increase the maximum number of participants?

    Read the article

  • Sending a Fax without a fax number

    - by Lynda
    I have an HP Officejet 8600 Pro that has faxing capabilities. However I do not send faxes often and I do not need to pay for a dedicated fax number/line. Is there a way to send and receive faxes using the built in wifi without a fax number from the HP? I have seen online services that allow this from the PC, is that the only way to do this? I am using Windows 7 for my OS. EDIT I do not use a regular phone line.

    Read the article

< Previous Page | 21 22 23 24 25 26 27 28 29 30 31 32  | Next Page >