Search Results

Search found 25754 results on 1031 pages for 'serial number'.

Page 26/1031 | < Previous Page | 22 23 24 25 26 27 28 29 30 31 32 33  | Next Page >

  • Varnish, hide port number

    - by George Reith
    My set up is as follows: OS: CentOS 6.2 running on an OpenVZ virtual machine. Web server: Nginx listening on port 8080 Reverse proxy: Varnish listening on port 80 The problem is that Varnish redirects my requests to port 8080 and this appears in the address bar like so http://mysite.com:8080/directory/, causing relative links on the site to include the port number (8080) in the request and thus bypassing Varnish. The site is powered by WordPress. How do I allow Varnish to use Nginx as the backend on port 8080 without appending the port number to the address? Edit: Varnish is set up like so: I have told the Varnish daemon to listen to port 80 by default. VARNISH_VCL_CONF=/etc/varnish/default.vcl # # # Default address and port to bind to # # Blank address means all IPv4 and IPv6 interfaces, otherwise specify # # a host name, an IPv4 dotted quad, or an IPv6 address in brackets. # VARNISH_LISTEN_ADDRESS= VARNISH_LISTEN_PORT=80 # # # Telnet admin interface listen address and port VARNISH_ADMIN_LISTEN_ADDRESS=127.0.0.1 VARNISH_ADMIN_LISTEN_PORT=6082 # # # Shared secret file for admin interface VARNISH_SECRET_FILE=/etc/varnish/secret # # # The minimum number of worker threads to start VARNISH_MIN_THREADS=1 # # # The Maximum number of worker threads to start VARNISH_MAX_THREADS=1000 # # # Idle timeout for worker threads VARNISH_THREAD_TIMEOUT=120 # # # Cache file location VARNISH_STORAGE_FILE=/var/lib/varnish/varnish_storage.bin # # # Cache file size: in bytes, optionally using k / M / G / T suffix, # # or in percentage of available disk space using the % suffix. VARNISH_STORAGE_SIZE=1G # # # Backend storage specification VARNISH_STORAGE="file,${VARNISH_STORAGE_FILE},${VARNISH_STORAGE_SIZE}" # # # Default TTL used when the backend does not specify one VARNISH_TTL=120 The VCL file that Varnish calls (through an include in default.vcl) consists of: backend playwithbits { .host = "127.0.0.1"; .port = "8080"; } acl purge { "127.0.0.1"; } sub vcl_recv { if (req.http.Host ~ "^(.*\.)?playwithbits\.com$") { set req.backend = playwithbits; set req.http.Host = regsub(req.http.Host, ":[0-9]+", ""); if (req.request == "PURGE") { if (!client.ip ~ purge) { error 405 "Not allowed."; } return(lookup); } if (req.url ~ "^/$") { unset req.http.cookie; } } } sub vcl_hit { if (req.http.Host ~ "^(.*\.)?playwithbits\.com$") { if (req.request == "PURGE") { set obj.ttl = 0s; error 200 "Purged."; } } } sub vcl_miss { if (req.http.Host ~ "^(.*\.)?playwithbits\.com$") { if (req.request == "PURGE") { error 404 "Not in cache."; } if (!(req.url ~ "wp-(login|admin)")) { unset req.http.cookie; } if (req.url ~ "^/[^?]+.(jpeg|jpg|png|gif|ico|js|css|txt|gz|zip|lzma|bz2|tgz|tbz|html|htm)(\?.|)$") { unset req.http.cookie; set req.url = regsub(req.url, "\?.$", ""); } if (req.url ~ "^/$") { unset req.http.cookie; } } } sub vcl_fetch { if (req.http.Host ~ "^(.*\.)?playwithbits\.com$") { if (req.url ~ "^/$") { unset beresp.http.set-cookie; } if (!(req.url ~ "wp-(login|admin)")) { unset beresp.http.set-cookie; } } }

    Read the article

  • Excel changing decimal places on number cells when I edit the cell's formula

    - by IanC
    I have a worksheet with thousands of number cells, all formatted "Number, 3 decimal places, use 1000 Separator ()". Starting a few days ago, if I edit a formula in any of these cells to reference another cell, Excel will change the decimal places to 14. For example, "=C$53^$B$4" = "=C$53^$B$10" will cause this. I am not aware of any settings being changed. Any ideas why this is happening and how to fix this?

    Read the article

  • How can I match an AWS account number to a key and secret

    - by iwein
    My client gave me a key and a secret to manage his EC2 things, but to make one of my AMI's available to run I have to fill in the Account Number. Is it possible to deduce the account number from the key and the secret? Obviously I also asked the client for this information, but since it's weekend and I'm not fond of waiting I wanted to see if I could figure it out myself. Have you done this before?

    Read the article

  • Tomcat 6 going down after reaching its maximum number of threads

    - by user73628
    Our Tomcat 6.0.29 goes down after reaching its maximum number of Threads. I would really appreciate any help with it because it is a production server. Here is part of the catalina.log file: INFO: Maximum number of threads (600) created for connector with address null and port 80 Mar 8, 2011 11:19:37 AM org.apache.coyote.http11.Http11Protocol pause INFO: Pausing Coyote HTTP/1.1 on http-80 Mar 8, 2011 11:19:38 AM org.apache.catalina.core.StandardService stop INFO: Stopping service Catalina Mar 8, 2011 11:19:38 AM org.apache.catalina.core.StandardWrapper unload INFO: Waiting for 8 instance(s) to be deallocated

    Read the article

  • C# SerialPort.GetPortNames() behavior

    - by Gunner
    In my C# 2008 application, I use the SerialPort.GetPortNames() function to retrieve the list of currently available ports. What I have noticed is, when ever I plug in a USB device, it's port number i s shown in the list on my Application and when I unplug it and refresh the list, the port number is no longer there. One phase of the application involves reading/writing data from/to the device continuously. Now, my expectation is, If I unplug the device during the operation and get the current Port list using SerialPort.GetPortNames(), the Port Name will not be there and I can use that to make the decision that the device has been unplugged. To my surprise, the Port name is still found despite having it removed Why is the program behaving like this? The port name isn't listed when in no-communication mode. Does it have something to do with the device being removed when it's communicating?

    Read the article

  • Issue with SPI (Serial Port Comm), stuck on ioctl()

    - by stef
    I'm trying to access a SPI sensor using the SPIDEV driver but my code gets stuck on IOCTL. I'm running embedded Linux on the SAM9X5EK (mounting AT91SAM9G25). The device is connected to SPI0. I enabled CONFIG_SPI_SPIDEV and CONFIG_SPI_ATMEL in menuconfig and added the proper code to the BSP file: static struct spi_board_info spidev_board_info[] { { .modalias = "spidev", .max_speed_hz = 1000000, .bus_num = 0, .chips_select = 0, .mode = SPI_MODE_3, }, ... }; spi_register_board_info(spidev_board_info, ARRAY_SIZE(spidev_board_info)); 1MHz is the maximum accepted by the sensor, I tried 500kHz but I get an error during Linux boot (too slow apparently). .bus_num and .chips_select should correct (I also tried all other combinations). SPI_MODE_3 I checked the datasheet for it. I get no error while booting and devices appear correctly as /dev/spidevX.X. I manage to open the file and obtain a valid file descriptor. I'm now trying to access the device with the following code (inspired by examples I found online). #define MY_SPIDEV_DELAY_USECS 100 // #define MY_SPIDEV_SPEED_HZ 1000000 #define MY_SPIDEV_BITS_PER_WORD 8 int spidevReadRegister(int fd, unsigned int num_out_bytes, unsigned char *out_buffer, unsigned int num_in_bytes, unsigned char *in_buffer) { struct spi_ioc_transfer mesg[2] = { {0}, }; uint8_t num_tr = 0; int ret; // Write data mesg[0].tx_buf = (unsigned long)out_buffer; mesg[0].rx_buf = (unsigned long)NULL; mesg[0].len = num_out_bytes; // mesg[0].delay_usecs = MY_SPIDEV_DELAY_USECS, // mesg[0].speed_hz = MY_SPIDEV_SPEED_HZ; mesg[0].bits_per_word = MY_SPIDEV_BITS_PER_WORD; mesg[0].cs_change = 0; num_tr++; // Read data mesg[1].tx_buf = (unsigned long)NULL; mesg[1].rx_buf = (unsigned long)in_buffer; mesg[1].len = num_in_bytes; // mesg[1].delay_usecs = MY_SPIDEV_DELAY_USECS, // mesg[1].speed_hz = MY_SPIDEV_SPEED_HZ; mesg[1].bits_per_word = MY_SPIDEV_BITS_PER_WORD; mesg[1].cs_change = 1; num_tr++; // Do the actual transmission if(num_tr > 0) { ret = ioctl(fd, SPI_IOC_MESSAGE(num_tr), mesg); if(ret == -1) { printf("Error: %d\n", errno); return -1; } } return 0; } Then I'm using this function: #define OPTICAL_SENSOR_ADDR "/dev/spidev0.0" ... int fd; fd = open(OPTICAL_SENSOR_ADDR, O_RDWR); if (fd<=0) { printf("Device not found\n"); exit(1); } uint8_t buffer1[1] = {0x3a}; uint8_t buffer2[1] = {0}; spidevReadRegister(fd, 1, buffer1, 1, buffer2); When I run it, the code get stuck on IOCTL! I did this way because, in order to read a register on the sensor, I need to send a byte with its address in it and then get the answer back without changing CS (however, when I tried using write() and read() functions, while learning, I got the same result, stuck on them). I'm aware that specifying .speed_hz causes a ENOPROTOOPT error on Atmel (I checked spidev.c) so I commented that part. Why does it get stuck? I though it can be as the device is created but it actually doesn't "feel" any hardware. As I wasn't sure if hardware SPI0 corresponded to bus_num 0 or 1, I tried both, but still no success (btw, which one is it?). UPDATE: I managed to have the SPI working! Half of it.. MOSI is transmitting the right data, but CLK doesn't start... any idea?

    Read the article

  • T-SQL - Left Outer Joins - Fileters in the where clause versus the on clause.

    - by Greg Potter
    I am trying to compare two tables to find rows in each table that is not in the other. Table 1 has a groupby column to create 2 sets of data within table one. groupby number ----------- ----------- 1 1 1 2 2 1 2 2 2 4 Table 2 has only one column. number ----------- 1 3 4 So Table 1 has the values 1,2,4 in group 2 and Table 2 has the values 1,3,4. I expect the following result when joining for Group 2: `Table 1 LEFT OUTER Join Table 2` T1_Groupby T1_Number T2_Number ----------- ----------- ----------- 2 2 NULL `Table 2 LEFT OUTER Join Table 1` T1_Groupby T1_Number T2_Number ----------- ----------- ----------- NULL NULL 3 The only way I can get this to work is if I put a where clause for the first join: PRINT 'Table 1 LEFT OUTER Join Table 2, with WHERE clause' select table1.groupby as [T1_Groupby], table1.number as [T1_Number], table2.number as [T2_Number] from table1 LEFT OUTER join table2 --****************************** on table1.number = table2.number --****************************** WHERE table1.groupby = 2 AND table2.number IS NULL and a filter in the ON for the second: PRINT 'Table 2 LEFT OUTER Join Table 1, with ON clause' select table1.groupby as [T1_Groupby], table1.number as [T1_Number], table2.number as [T2_Number] from table2 LEFT OUTER join table1 --****************************** on table2.number = table1.number AND table1.groupby = 2 --****************************** WHERE table1.number IS NULL Can anyone come up with a way of not using the filter in the on clause but in the where clause? The context of this is I have a staging area in a database and I want to identify new records and records that have been deleted. The groupby field is the equivalent of a batchid for an extract and I am comparing the latest extract in a temp table to a the batch from yesterday stored in a partioneds table, which also has all the previously extracted batches as well. Code to create table 1 and 2: create table table1 (number int, groupby int) create table table2 (number int) insert into table1 (number, groupby) values (1, 1) insert into table1 (number, groupby) values (2, 1) insert into table1 (number, groupby) values (1, 2) insert into table2 (number) values (1) insert into table1 (number, groupby) values (2, 2) insert into table2 (number) values (3) insert into table1 (number, groupby) values (4, 2) insert into table2 (number) values (4)

    Read the article

  • .NET Serial Port: Port Configuration Dialog

    - by sheepsimulator
    I'm going to be writing a small app based on the .NET SerialPort class. Is there a generic dialog available for setting the port settings, ala baud rate, data bits, stop bit, parity bit, flow control, etc? I didn't see one in the MSDN documentation, but I would think that one exists, since that stuff doesn't change.

    Read the article

  • Document Based Application, preinitialize window (enter serial, buy, trial)

    - by Remizorrr
    I need to create several windows before NSDocument is loaded, or create a window that blocks NSDocument window and top menu. I tried several solutions - but they didn't work right. modal window, one after another. there were some problems with Async URLConnection, and some other problems with my NSDocument content. I created custom MainMenu.xib with no menu, that opens my preinitialize windows. here i found some other problems, when a file(associated with my application) is opened - the Document Window initializes. Here i tried to subclass NSDocumentController, but i found no way to pause the "open document". (i want the document to be opened anyway, but only after the preinitalize windows would be closed). So what is the right way to do this?

    Read the article

  • serial port does not exist in current context: c#

    - by I__
    here's the code: using System; using System.Collections.Generic; using System.ComponentModel; using System.Data; using System.Drawing; using System.Linq; using System.Text; using System.Windows.Forms; using System.Threading; namespace WindowsFormsApplication1 { public partial class Form1 : Form { public Form1() { InitializeComponent(); } public class ThreadWork { private static SerialPort serialPort1; public static void DoWork() { serialPort1.Open(); serialPort1.Write("AT+CMGF=1\r\n"); //Thread.Sleep(500); serialPort1.Write("AT+CNMI=2,2\r\n"); //Thread.Sleep(500); serialPort1.Write("AT+CSCA=\"+4790002100\"\r\n"); //Thread.Sleep(500); serialPort1.DataReceived += serialPort1_DataReceived_1; } } private void Form1_Load(object sender, EventArgs e) { ThreadStart myThreadDelegate = new ThreadStart(ThreadWork.DoWork); Thread myThread = new Thread(myThreadDelegate); myThread.Start(); } private void serialPort1_DataReceived_1(object sender, System.IO.Ports.SerialDataReceivedEventArgs e) { string response = serialPort1.ReadLine(); this.BeginInvoke(new MethodInvoker(() => textBox1.AppendText(response + "\r\n"))); } } } and i get an error on this line: string response = serialPort1.ReadLine(); it says:: Error 1 The name 'serialPort1' does not exist in the current context C:\Users\alexluvsdanielle\AppData\Local\Temporary Projects\WindowsFormsApplication1\Form1.cs 44 31 WindowsFormsApplication1 what am i doing wrong?

    Read the article

  • Confusion with a while statement evaluating if a number is triangular

    - by Darkkurama
    I've been having troubles trying to figure out how to solve a function. I've been assigned the development of a little programme which tells if a number is "triangular" (a number is triangular when the addition of certain consecutive numbers in the [1,n] interval is n. Following the definition, the number 10 is triangular, because in the [1,10] interval, 1+2+3+4=10). I've coded this so far: class TriangularNumber{ boolean numTriangular(int n) { boolean triangular = false; int i = n; while(n>=0 && triangular){ //UE06 is a class which contains the function "f0", which makes the addition of all the numbers in a determined interval UE06 p = new UE06(); if ((p.f0(1, i))==n) triangular = true; else i=i-1; } return triangular; } boolean testTriangular = numTriangular(10) == true && numTriangular(7) == false && numTriangular(6) == true; public static void main(String[] args){ TriangularNumber p = new TriangularNumber(); System.out.println("testTriangular = " + p.testTriangular); } } According to those boolean tests I made, the function is wrong. As I see the function, it goes like this: I state that the input number in the initial state isn't triangular (triangular=false) and i=n (determining the interval [1,i] where the function is going to be evaluated While n is greater or equals 0 and the number isn't triangular, the loop starts The loop goes like this: if the addition of all the numbers in the [1,i] interval is n, the number is triangular, causing the loop to end. If that statement is false, i goes from i to (i-1), starting the loop again with that particular interval, and so on till the addition is n. I can't spot the error in my "algorithm", any advice? Thanks!

    Read the article

  • Increment the number of times an article has been read

    - by r.sendecky
    I have a situation where I need to increase the number of time article has been read. Once someone opens an article it should be reflected in the database by incrementing number of reads by one. Simple. Sending POST request to the server increments the number of reads by one. The article in question is supplied via URL parameter. Doing it manually by typing the URL in a browser works as expected. So server side is not at fault. My problems start with the javascript side of it or rather jquery. I hook the event to the article link. So every time a user clicks on the article link it increments the number of reads like so: $('#list-articles .article-link').click(function(e){ var oid = $(this).parent().parent().attr('data-oid').toString(); //Get the article id $.post( "/articles/viewed/" + oid ); }); Now this does not work! Number is not increased. I don't prevent default action since I need the link to actually open and display the article. Now if I put an alert right after the post like this: $('#list-articles .article-link').click(function(e){ var oid = $(this).parent().parent().attr('data-oid').toString(); //Get the article id $.post( "/articles/viewed/" + oid ); alert(oid); }); This variant works. After I dismiss the alert window, the number is incremented. Why is this so?? How can I fix this to actually work without the alert event present?

    Read the article

  • generate k distinct number less then n

    - by davit-datuashvili
    hi i have following question task is this generate k distinct positive numbers less then n without duplication my method is following first create array size of k where we should write these numbers int a[]=new int[k]; //now i am going to cretae another array where i check if (at given number position is 1 then generate number again else put this number in a array and continue cycle i put here a piece of code and explanations int a[]=new int[k]; int t[]=new int[n+1]; Random r=new Random(); for (int i==0;i<t.length;i++){ t[i]=0;//initialize it to zero } int m=0;//initialize it also for (int i=0;i<a.length;i++){ m=r.nextInt(n);//random element between 0 and n if (t[m]==1){ //i have problem with this i want in case of duplication element occurs repeats this steps afain until there will be different number else{ t[m]=1; x[i]=m; } } so i fill concret my problem if t[m]==1 it means that this element occurs already so i want to generate new number but problem is that number of generated numbers will not be k beacuse if i==0 and occurs duplicate element and we write continue then it will switch at i==1 i need like goto for repeat step or for (int i=0;i<x.length;i++){ loop: m=r.nextInt(n); if ( x[m]==1){ continue loop; } else{ x[m]=1; a[i]=m; continue;//continue next step at i=1 and so on } } i need this code in java please help

    Read the article

  • jQuery unbinding click event when maximum number of children are displayed

    - by RyanP13
    I have a personal details form that alows you to enter a certain number of dependants which is determined by the JSP application. The first dependant is visible and the user has the option to add dependants up to the maximum number. All other dependants are hidden by default and are displayed when a user clicks the 'Add another dependant button'. When the maximum number of dependants has been reached the button is greyed out and a message is generated via jQuery and displayed to tell the user exactly this. The issue i am having is when the maximum number of dependants has been reached the message is displayed but then the user can click the button to add more dependants and the message keeps on generating. I thought unbinding the click event would sort this but it seems to still be able to generate a second message. Here is the function i wrote to generate the message: // Dependant message function function maxDependMsg(msgElement) { // number of children can change per product, needs to be dynamic // count number of dependants in HTML var $dependLength = $("div.dependant").length; // add class maxAdd to grey out Button // create maximum dependants message and display, will not be created if JS turned off $(msgElement) .addClass("maxAdd") .after($('<p>') .addClass("maxMsg") .append("The selected web policy does not offer cover for more than " + $dependLength + " children, please contact our customer advisers if you wish discuss alternative policies available.")); } There is a hyperlink with a click event attached like so: $("a.add").click(function(){ // Show the next hidden table on clicking add child button $(this).closest('form').find('div.dependant:hidden:first').show(); // Get the number of hidden tables var $hiddenChildren = $('div.dependant:hidden').length; if ($hiddenChildren == 0) { // save visible state of system message $.cookies.set('cpqbMaxDependantMsg', 'visible'); // show system message that you can't add anymore dependants than what is on page maxDependMsg("a.add"); $(this).unbind("click"); } // set a cookie for the visible state of all child tables $('div.dependant').each(function(){ var $childCount = $(this).index('div.dependant'); if ($(this).is(':visible')) { $.cookies.set('cpqbTableStatus' + $childCount, 'visible'); } else { $.cookies.set('cpqbTableStatus' + $childCount, 'hidden'); } }); return false; }); All of the cookies code is for state saving when users are going back and forward through the process.

    Read the article

  • Python File Search Line And Return Specific Number of Lines after Match

    - by Simos Anderson
    I have a text file that has lines representing some data sets. The file itself is fairly long but it contains certain sections of the following format: Series_Name INFO Number of teams : n1 | Team | # | wins | | TeamName1 | x | y | . . . | TeamNamen1 | numn | numn | Some Irrelevant lines Series_Name2 INFO Number of teams : n1 | Team | # | wins | | TeamName1 | num1 | num2 | . where each section has a header that begins with the Series_Name. Each Series_Name is different. The line with the header also includes the number of teams in that series, n1. Following the header line is a set of lines that represents a table of data. For each series there are n1+1 rows in the table, where each row shows an individual team name and associated stats. I have been trying to implement a function that will allow the user to search for a Team name and then print out the line in the table associated with that team. However, certain team names show up under multiple series. To resolve this, I am currently trying to write my code so that the user can search for the header line with series name first and then print out just the following n1+1 lines that represent the data associated with the series. Here's what I have come up with so far: import re print fname = raw_input("Enter filename: ") seriesname = raw_input("Enter series: ") def findcounter(fname, seriesname): logfile = open(fname, "r") pat = 'INFO Number of teams :' for line in logfile: if seriesname in line: if pat in line: s=line pattern = re.compile(r"""(?P<name>.*?) #starting name \s*INFO #whitespace and success \s*Number\s*of\s*teams #whitespace and strings \s*\:\s*(?P<n1>.*)""",re.VERBOSE) match = pattern.match(s) name = match.group("name") n1 = int(match.group("n1")) print name + " has " + str(n1) + " teams" lcount = 0 for line in logfile: if line.startswith(name): if pat in line: while lcount <= n1: s.append(line) lcount += 1 return result The first part of my code works; it matches the header line that the person searches for, parses the line, and then prints out how many teams are in that series. Since the header line basically tells me how many lines are in the table, I thought that I could use that information to construct a loop that would continue printing each line until a set counter reached n1. But I've tried running it, and I realize that the way I've set it up so far isn't correct. So here's my question: How do you return a number of lines after a matched line when given the number of desired lines that follow the match? I'm new to programming, and I apologize if this question seems silly. I have been working on this quite diligently with no luck and would appreciate any help.

    Read the article

  • Binary to Ascii and back again

    - by rross
    I'm trying to interface with a hardware device via the serial port. When I use software like Portmon to see the messages they look like this: 42 21 21 21 21 41 45 21 26 21 29 21 26 59 5F 41 30 21 2B 21 27 42 21 21 21 21 41 47 21 27 21 28 21 27 59 5D 41 32 21 2A 21 28 When I run them thru a hex to ascii converter the commands don't make sense. Are these messages in fact something different than hex? My hope was to see the messages the device is passing and emulate them using c#. What can I do to find out exactly what the messages are?

    Read the article

  • Ruby SerialPorts Gem

    - by Seth Archer
    Using Ruby SerialPorts Gem to interact with hardware. When I write a byte array to the hardware using a program called "Serial Port Monitor" the hardware responds correctly. However, when I write the same byte array using ruby it doesn't work unless I do a read request just before the write request. This device doesn't respond correctly with this sp = SerialPort.new(args) sp.write [200.chr, 30.chr, 6.chr, 5.chr, 1.chr, 2.chr, 0.chr, 244.chr] But it does if I add a read request before the write. Like this sp SerialPort.new(args) sp.read sp.write [200.chr, 30.chr, 6.chr, 5.chr, 1.chr, 2.chr, 0.chr, 244.chr] This works, but I'm at a loss as to why. I should also add that the first snippet does work occasionally maybe 1/10 of the time.

    Read the article

  • Java RS232 Comm on Vista-64 bit

    - by DD
    We have a Java application which needs to communicate with a peripheral device over Virtual Serial COM port. We use the RS232 Java COMM API (javax.comm.properties, comm.jar, win32com.dll) to achieve the same. Currently the code works fine on Windows XP 32-bit, Vista 32-bit and Windows 7. However we are having a problem trying to communicate on Vista 64-bit. I read from the Java forums that there is no 64-bit support for the Java COMM API I was wondering if anyone was facing a similar situation and were able to resolve the same in some way?

    Read the article

  • DataReceived Event handler not receiving messages

    - by karthik
    I'm using the below code to receive the messages using serial port event handler. But it dosent receives any.I am not getting errors. The code breaks in "string msg = comport.Readline()" Am i doing something wrong ? public partial class SerialPortScanner : Form { private SerialPort comPort = new SerialPort(); public SerialPortScanner() { InitializeComponent(); comPort.Open(); comPort.DataReceived += new SerialDataReceivedEventHandler(comPort_DataReceived); } void comPort_DataReceived(object sender, SerialDataReceivedEventArgs e) { if (comPort.IsOpen == true) { string msg = comPort.ReadLine(); MessageBox.Show(msg); } } }

    Read the article

  • DataReceived Event handler not receiving messages using c#

    - by karthik
    I'm using the below code to receive the messages using serial port event handler. But it dosent receives any.I am not getting errors. The code breaks in "string msg = comport.Readline()" Am i doing something wrong ? public partial class SerialPortScanner : Form { private SerialPort comPort = new SerialPort(); public SerialPortScanner() { InitializeComponent(); comPort.Open(); comPort.DataReceived += new SerialDataReceivedEventHandler(comPort_DataReceived); } void comPort_DataReceived(object sender, SerialDataReceivedEventArgs e) { if (comPort.IsOpen == true) { string msg = comPort.ReadLine(); MessageBox.Show(msg); } } }

    Read the article

  • Multiple port asynchronous I/O over serialport in C#

    - by firoso
    I'm trying to write a test application for serial I/O (RS-232) with multiple units in C# and I'm running into an issue with my lack of threading experience so I'm soliciting feedback for a best known method. I've got a pool of COM ports COM1-16 each of which can read/write at any time and I need to be able to manage them simultaneously. Is this a situation for a thread pool? What is some guidance on structuring this applet? Edit: Upon review I was wondering is I really even need to do asynchronous threads here, I could just maintain states for each COM-port and do flow logic (i.e., statemachine) for each COM-port individually.

    Read the article

  • programmatically controlling power sockets in the UK

    - by cartoonfox
    It's very simple. I want to plug a lamp into the UK mains supply. I want to be able to power it on and off from software - say from serial port commands, or by running a command-line or something I can get to from ruby or Java. I see lots written about how to do this with X10 with American power systems - but has anybody actually tried doing this in the UK? If you got this working: 1) Exactly what hardware did you use? 2) How do you control it from software? Thanks!

    Read the article

< Previous Page | 22 23 24 25 26 27 28 29 30 31 32 33  | Next Page >