Search Results

Search found 14757 results on 591 pages for 'switch statement'.

Page 25/591 | < Previous Page | 21 22 23 24 25 26 27 28 29 30 31 32  | Next Page >

  • Two hosts on same subnet can't see each other

    - by Joey Hewitt
    I've got two routers with two separate public IP addresses on the same subnet, but I can't get them to talk to each other. Both are connected to the internet (ISP-provided gateway) via Ethernet ports provided by the landlord, but I don't have access to or knowledge of how those are physically connected or the protocols used to get back to the ISP. I can ping either from the outside, but they can't ping each other. Traceroutes in and out look the same, and they receive the same gateway over DHCP. I can ping other IPs on the subnet, so I assume this is not any sort of intentional isolation for security/privacy. Since I'm in a setup where my landlord provides internet and we don't have contact with the ISP, I can't really ask the ISP for help (doubt the landlord would know much either.) The situation is similar to the diagram at this question, but instead of the two servers, there's another router coming off the (presumed) switch, and I don't have access to the switch. I've tried giving them static routes to each other with the ISP internet gateway as the gateway, but that's not working. One is a Linksys WRT54GL running DD-WRT, the other is a Netgear WGR614v7, although I could get something more capable if necessary. I'd like to keep them each connected directly to the ISP on their WAN ports, but I can have an ethernet cable between them if necessary - I'm wondering if there's a way without that, and if there isn't, I'd appreciate advice on how to get that working. Sorry this is so nitpicky; there are reasons for all the constraints, but they don't apply to the real question, so I left them out. ;) Thank you!

    Read the article

  • What could be wrong with my VLAN?

    - by Matt
    I've got a VLAN 10 setup as a management VLAN. The management VLAN comes off port 48 and links to another set of switches that do not support VLAN's so it was I believe set up as an untagged access port. In the past this was a different brand of switch and this worked fine. However, since changing to the HP V1910-48G series I can't seem to get this working. I must point out that as far as I'm aware it is wired up properly (I can't check this physically as I'm working remote and have asked the tech who's got access to double check for me). Now I don't have a huge amount of experience with VLAN environments but AFAIK this is right. I've set the port 48 (linked to the management switches) as an untagged port with PVID 10 and access link type. Is this all I'd need to do from a configuration perspective to ensure all devices connected to port 48 would end up being on VLAN 10 and not needing to tag their frames. i.e. the tag would be added by the switch before being forwarded.

    Read the article

  • Stack Managed Switches over a distance

    - by Joel Coel
    We have several buildings with stacked switches, where the distance between the stacked units is considerable... separate floors, or at opposite ends of a hallway. They are 3Com switches that stack using cat6 cabling. These switches are coming up on 12 years old now, and as I look around at replacements it seems no one supports this scenario any more. Stacking switches want to use fiber links (it more for me to run and terminate the fiber stacking cables than to purchase the switch) or other custom cables that seem only intended to jump up to the next unit in a rack. What have others done to support stacking over a distance? I'm considering breaking up the stacked switches into separate managed entities and just bridging from the root switch in the buildings, but I'd really like to avoid that for what I hope are obvious reason. The closest thing I've found are from netgear that use hdmi cables for the stacking connection... I could try to support that by running an additional cat6 line and re-terminating both links into a single hdmi port, but I have concerns over that approach as well.

    Read the article

  • Network switches for LAN party

    - by guywhoneedsahand
    I am working on setting up the network for a small LAN party (less than 16 people). Most of them do not have wireless cards in their rigs, so I need to set up some way for everyone to a) play LAN games and b) access the internet. The LAN party will probably take place in my basement, where I have enough space. However, the basement is not wired up with the router which is actually on the floor above. I make a cantenna a while back that can boost the wireless performance of my computer significantly. How can I use this to provide internet and LAN to guests? My hope was that I could use a switch like this http://www.newegg.com/Product/Product.aspx?Item=N82E16833181166 for the LAN - but how can I give people access to the internet? Is there such thing as a network extender / 16-port switch? Obviously, the internet performance doesn't need to be super stellar, because the games will be using LAN - so I am looking to provide some usable internet for web browsing, and very high speed LAN for games. Thanks!

    Read the article

  • What differences are there between "home" switches and "professional" switches?

    - by pjreddie
    Our radio station uses a PtP wireless system to stream our radio and TV signals from our studio up a hill to our transmitter. We have been having problems with warbly sound and drop outs that come from some point in this system. An engineer that occasionally visits the station thinks it could be the switches we use on each side of the PtP wireless system to connect the PtP devices to the encoders and decoders and wants us to get two of these switches: http://www.amazon.com/Netgear-JGS516-ProSafe-16-Port-Ethernet/dp/B0002CWPOK/ref=dp_return_1 The encoder/decoder setup only streams 8Mbps total so it seems like the switches we have should not be stressed out, unless they are causing sufficient latency to degrade the performance of the encoder/decoder. At each end of the connection we only have 4 connections, is there any reason we couldn't get a cheaper, "home" quality switch like this: http://www.amazon.com/D-Link-DGS-1005G-5-Port-Gigabit-Desktop/dp/tech-data/B003X7TRWE/ref=de_a_smtd Is there a significant difference that we would notice in terms of latency between these two switches? How much does the quality of the switch actually matter in this scenario? Any help is appreciated, feel free to ask questions if anything needs clarification. Thanks

    Read the article

  • Uninstalled server 2008 now router won't handle DHCP

    - by john
    My set up is this. server behind router, router has a server and switch connected to it with multiple computers. router used to serve DHCP and DNS, a couple of days ago installed AD, DNS and DHCP on the server, and the server gave out IP's. For various reasons we had to uninstall the domain on our server. I removed AD, DHCP and DNS from the roles and set the router back to serving DHCP and DNS. Now I can't get computers on the network. I reset my router back to factory defaults, and if I plug a computer directly into the router I can get a IP address, but all the computers behind the switch can't get an IP address and can't see the router. All my computers say unidentified network, and if I ping the router it says host is unreachable. On the other hand, my wireless devices are just fine and connect no problem. But for desktops, ipconfig /release doesn't release anything and /renew can't find a server to renew on. My router log shows several FIN scans but they are from innocuous websites (google, netgear) and it shows a couple of smurf attacks but they are all from my external IP. Any ideas? the server isn't even connected to the route right now, and all the computers are set for dynamic IP addresses.. I don't know what else to try? Any help?

    Read the article

  • Seeing traffic destined for other people's servers in wireshark

    - by user350325
    I rent a dedicated server from a hosting provider. I ran wireshark on my server so that I could see incoming HTTP traffic that was destined to my server. Once I ran wireshark and filtered for HTTP I noticed a load of traffic, but most of it was not for stuff that was hosted on my server and had a destination IP address that was not mine, there were various source IP addresses. My immediate reaction was to think that somebody was tunnelling their HTTP traffic through my server somehow. However when I looked closer I noticed that all of this traffic was going to hosts on the same subnet and all of these IP addresses belonged to the same hosting provider that I was using. So it appears that wireshark was intercepting traffic destined for other customers who's servers are attached to the same part of the network as mine. Now I always assumed that on a switch based network that this should not happen as the switch will only send data to the required host and not to every box attached. I assume in this case that other customers would also be able to see data going to my server. As well as potential privacy concerns, this would surely make ARP poising easy and allow others to steal IP addresses (and therefor domains and websites)? It would seem odd that a network provider would configure the network in such a way. Is there a more rational explanation here?

    Read the article

  • Issues connecting to HP ProCurve switches

    - by BriGuy
    We are having a very strange issue trying to connect to our infrastructure switches via SSH. When you first try connecting to them, the switches will prompt for the password - and then just sit there after it is entered. If you create a second SSH session to the switch (while letting the first one remain open and just sitting there) it will let you log right in. The switches are doing the same thing with RADIUS and local authentication. The other strange part to all of this, is that about 10 switches started doing it all at the same time. As far as actual configuration of the switches, nothing has changed. Occasionally, one switch will start working like normal, but then stop again. These are all HP ProCurve managed switches, but all different models/firmware. Some switches that are not working are using the same firmware as others that are working. UPDATE: 20130312 I am also seeing this same behavior when trying to use telnet. The first telnet session just hangs there, and the second telnet session will let me log in. Rebooting the switches seems to get them working, but I still have 5 production switches that cannot easily be rebooted because of their production roles. Is anyone aware of anything else that can be switched on/off that may reset the logon for remote management or something like that?

    Read the article

  • sql insert statement with a lot of same where clause and one different where cluase

    - by william
    I m sry if the title is not clear. Here's my proble. I created a new table which will show total, average and maximum values. I have to insert the results into that table. That table will have only 4 rows. No Appointment, Appointment Early, Appointment Late and Appointment Punctual. So.. I have sth like.. insert into newTable select 'No Appointment' as 'Col1', avg statement, total statement, max statement from orgTable where (general conditions) and (unique condition to check NO APPOINTMENT); I have to do that same thing for another 3 rows.. where only the unique condition is different to check early, punctual or late.. So..the statement is super long. I wanna reduce the size.. How can I achieve that?

    Read the article

  • Number of characters recommended for a statement

    - by liaK
    Hi, I have been using Qt 4.5 and so do C++. I have been told that it's a standard practice to maintain the length of each statement in the application to 80 characters. Even in Qt creator we can make a right border visible so that we can know whether we are crossing the 80 characters limit. But my question is, Is it really a standard being followed? Because in my application, I use indenting and all, so it's quite common that I cross the boundary. Other cases include, there might be a error statement which will be a bit explanatory one and which is in an inner block of code, so it too will cross the boundary. Usually my variable names look bit lengthier so as to make the names meaningful. When I call the functions of the variable names, again I will cross. Function names will not be in fewer characters either. I agree a horizontal scroll bar shows up and it's quite annoying to move back and forth. So, for function calls including multiple arguments, when the boundary is reached I will make the forth coming arguments in the new line. But besides that, for a single statement (for e.g a very long error message which is in double quotes " " or like longfun1()->longfun2()->...) if I use an \ and split into multiple lines, the readability becomes very poor. So is it a good practice to have those statement length restrictions? If this restriction in statement has to be followed? I don't think it depends on a specific language anyway. I added C++ and Qt tags since if it might. Any pointers regarding this are welcome.

    Read the article

  • && (AND) and || (OR) in Java IF statements

    - by Azimuth
    My question might be very basic but still I think it worths to ask. I have the following code: if(!partialHits.get(req_nr).containsKey(z) || partialHits.get(req_nr).get(z) < tmpmap.get(z)){ partialHits.get(z).put(z, tmpmap.get(z)); } where partialHits is a HashMap. What will happen if the first statement is true? Will Java still check the second statement? Because in order the first statement to be true, the HashMap should not contain the given key, so if the second statement is checked, I will get NullPointerException. So in simple words, if we have the following code if(a && b) if(a || b) would Java check b if a is false in the first case and if a is true in the second case?

    Read the article

  • Network using only switches

    - by mschultz
    So I'm not a network guy - but here's what I want to do - I have an existing network using wifi, which I like, and which is used to connect several computers to the internet. It is headed up by a router, which is in another part of the building. Three of those computers are in my office. All three have gigabit wired ethernet. I have a gigabit switch. Here's what I want to do: Build a 2nd network, out of just that switch, which allows all 3 computers to connect to each other (just to each other is fine, for this purpose, they need no internet). I have a distributed computing task (rendering high-quality fractal artwork, as it were), that requires the best connection speed to all 3 computers. I want them to be able to "talk to each other" as quickly as possible, with the fewest dropped packets (the dataflow over this network will be quite high). So how do I do this. I'm not a networking guy at all - I tried connecting them all, and nobody got an IP address (which I assume is because nobody is running a DNS server?). What all do I need to do to make this work? PS - two are running windows, one is running ubuntu.

    Read the article

  • Router and Switch VLAN Configuration for Isolated Network

    - by Ben
    I haven't worked with VLANs much in the past and I was hoping if I could get a good explanation of what I need to setup for this to work. I have a Netgear WNR2000v2 router and a Netgear GS108T smart switch currently in my network. The fourth port on the router connects to port one on the switch. I would like to be able to isolated port 8 on the switch for use as a "guest port" when I bring home malware infested PCs for repair. I figured the VLAN capabilities of the GS108T would be able to do this for me, but I think I have a misunderstanding of how the VLAN actually works. Port 8 needs internet access but should not be able to communicate with the rest of the PCs on the home network. The subnet for the home network is 192.168.1.0/24 and I would like the guest PC to have A) 192.168.1.64 or B) 192.168.2.2. I am reading a lot of stuff about port trunking and VLAN membership, but I am confused as to which setup needs to be in place to make this work. Any help is greatly appreciated! Let me know if there is more information I need to provide. Definitely looking to learn something from this project. Thanks!

    Read the article

  • Sonicwall NSA 240, Configured for LAN and DMZ, X0 and X2 on same switch - ping issues

    - by Klaptrap
    Our Sonicwall vendor supplied and networked the NSA240 when we required a DMZ in our infrastructure. This was configured and appeared correct although VPN users periodically dropped DNS and Terminal Services. The vendor could not resolve and so the call was escalated to Sonicwall. The Sonicwall support engineer took a look and concluded that the X0 (LAN) and X2 (DMZ) intefaces were cabled to the same switch and so this is the issue. What he observed is a ping request to the LAN Domain Controller, from a connected VPN user, is forwarded (x0) from the VPN client IP to the DC IP but the ping response from the DC IP to the VPN client IP is on X2, a copy of the log is detailed below:- 02/02/2011 10:47:49.272 X1*(hc) X0 192.168.1.245 192.168.1.8 IP ICMP -- FORWARDED 02/02/2011 10:47:49.272 -- X0* 192.168.1.245 192.168.1.8 IP ICMP -- FORWARDED 02/02/2011 10:47:49.272 X2*(i) -- 192.168.1.8 192.168.1.245 IP ICMP -- Received X0 - LAN X1 - WAN X2 - DMZ The Sonicwall engineer concluded that we either need a seperate switch for X2 or we use a VLAN switch for both. I am the companies software engineer and we have yet to have heard back from the vendor, so I am lost at sea at the moment. Do we need to buy this additional equipment or is there another configuration on the NSA240 we can use?

    Read the article

  • A switch and router between the printer and PC that want to print but cannot

    - by Robert Memo
    IP 192.168.1.5 has a wireless connection to a Linksys router (192.168.1.1) which then is connected to a switch. The switch is connected to a server (192.168.0.2). My printer has IP address of 192.168.0.8. Internet connection is fine on 192.168.1.5. Problem 1: IP 192.168.1.5 can not print using printer 192.168.0.8. Problem 2: IP 192.168.1.2 can not access a shared folder on the the server. The reason for connecting this way is that, the server does not release wireless signal. In order to get wireless signal the Router is connected to the switch. The server is a computer server that only has one outgoing LAN port. Plus, due to inconvinience physical locations, I do not have option to change the physical locations and the way it is connected already. I just want the labtops that only have wireless connection to communicate with the printer and the server. I have tried to change the router IP address to 192.168.0.x like the server and printer. It caused problem for the laptop. The router no longer release internet signals. The router does have IP address from the server 192.168.0.5.

    Read the article

  • IOGEAR GCS632U KVM casues Windows 7 Screensaver to not work

    - by ahsteele
    When my Windows 7 laptop is in its dock and connected to the IOGEAR GCS632U KVM switch the screensaver will not start. If connected directly to the mouse and keyboard while in the dock the screensaver starts normally. The screensaver also works when out of the dock. I need the screensaver to work when connected to the KVM. What's causing the screensaver not to start? Suggestions on how to remedy the problem?

    Read the article

  • HP ProCurve Port Mode Configuration Question

    - by SvrGuy
    We have a ProCurve Switch 2810-48G (J9022A). We need to disable auto negotiation on two ports and manually configure them to be full duplex gige ports. From the web GUI, Configuration Tab, Port Configuration sub tab, I am only presented with the option to configure the port as Auto - 1000. I take this to mean, auto negotiate duplex, manually configure the speed to be gige. How do I manually configure the port such that it is manually configured to use full duplex, 1000 mbs?

    Read the article

  • Daisy-chaining network switches with multiple cables

    - by user72153
    This might just be the dumbest question you'll ever read, but I digress. Say I have two 100Mbps Ethernet switches with 2 computers on each, connected together by a single cable. This way, the two PCs on each switch share the 100Mbps bandwidth with the others. If I added another cable between the 2 switches, would there be 200Mbps throughput available between the switches? Or am I completely off my rocker? Thanks for the help.

    Read the article

  • Why does a wired network slow down with user increase?

    - by Ed Briscoe
    If you had a wired network, 20 PCs hooked up to a 100 Mbit/sec switch (same onboard ethernet port speed) and you were just sending some test data round. What is the technical explanation as to why 20 machines sending test data around this network to each other is slower than one to one? I mean I know a busy network means it's slower but I'm really trying to understand some more technical details. Thanks for any help

    Read the article

  • Spanning-tree setup with incompatible switches

    - by wfaulk
    I have a set of eight HP ProCurve 2910al-48G Ethernet switches at my datacenter that are set up in a star topology with no physical loops. I want to partially mesh the switches for redundancy and manage the loops with a spanning-tree protocol. However, our connection to the datacenter is provided by two uplinks, each to a Cisco 3750. The datacenter's switches are handling the redundant connection using PVST spanning-tree, which is a Cisco-proprietary spanning-tree implementation that my HP switches do not support. It appears that my switches are not participating in the datacenter's spanning-tree domain, but are blindly passing the BPDUs between the two switchports on my side, which enables the datacenter's switches to recognize the loop and put one of the uplinks into the Blocking state. This is somewhat supposition, but I can confirm that, while my switches say that both of the uplink ports are forwarding, only one is passing any real quantity of data. (I am assuming that I cannot get the datacenter to move away from PVST. I don't know that I'd want them to make that significant of a change anyway.) The datacenter has also sent me this output from their switches (which I have expurgated of any identifiable info): 3750G-1#sh spanning-tree vlan nnn VLAN0nnn Spanning tree enabled protocol ieee Root ID Priority 10 Address 00d0.0114.xxxx Cost 4 Port 5 (GigabitEthernet1/0/5) Hello Time 2 sec Max Age 20 sec Forward Delay 15 sec Bridge ID Priority 32mmm (priority 32768 sys-id-ext nnn) Address 0018.73d3.yyyy Hello Time 2 sec Max Age 20 sec Forward Delay 15 sec Aging Time 300 sec Interface Role Sts Cost Prio.Nbr Type ------------------- ---- --- --------- -------- -------------------------------- Gi1/0/5 Root FWD 4 128.5 P2p Gi1/0/6 Altn BLK 4 128.6 P2p Gi1/0/8 Altn BLK 4 128.8 P2p and: 3750G-2#sh spanning-tree vlan nnn VLAN0nnn Spanning tree enabled protocol ieee Root ID Priority 10 Address 00d0.0114.xxxx Cost 4 Port 6 (GigabitEthernet1/0/6) Hello Time 2 sec Max Age 20 sec Forward Delay 15 sec Bridge ID Priority 32mmm (priority 32768 sys-id-ext nnn) Address 000f.f71e.zzzz Hello Time 2 sec Max Age 20 sec Forward Delay 15 sec Aging Time 300 sec Interface Role Sts Cost Prio.Nbr Type ------------------- ---- --- --------- -------- -------------------------------- Gi1/0/1 Desg FWD 4 128.1 P2p Gi1/0/5 Altn BLK 4 128.5 P2p Gi1/0/6 Root FWD 4 128.6 P2p Gi1/0/8 Desg FWD 4 128.8 P2p The uplinks to my switches are on Gi1/0/8 on both of their switches. The uplink ports are configured with a single tagged VLAN. I am also using a number of other tagged VLANs in my switch infrastructure. And, to be clear, I am passing the tagged VLAN I'm receiving from the datacenter to other ports on other switches in my infrastructure. My question is: how do I configure my switches so that I can use a spanning tree protocol inside my switch infrastructure without breaking the datacenter's spanning tree that I cannot participate in?

    Read the article

  • alias name in brocade

    - by wildchild
    how do i look for alias name using the WWN in brocade. Say i have created an alias "CentosNode2Port1" using switch show i get the WWN ,but how to look for the alias name. alishow (WWN) is not accepting. please help

    Read the article

< Previous Page | 21 22 23 24 25 26 27 28 29 30 31 32  | Next Page >