  • Interrupting Prototype handler, alert() vs event.stop()

    - by lxs
    Here's the test page I'm using. This version works fine, forwarding to #success: <!DOCTYPE html PUBLIC "-//W3C//DTD XHTML 1.0 Strict//EN" "http://www.w3.org/TR/xhtml1/DTD/xhtml1-strict.dtd"> <html><head> <script type="text/javascript" src="prototype.js"></script> </head><body> <form id='form' method='POST' action='#fail'> <button id='button'>Oh my giddy aunt!</button> <script type="text/javascript"> var fn = function() { $('form').action = "#success"; $('form').submit(); } $('button').observe('mousedown', fn); </script> </form> </body></html> If I empty the handler: var fn = function() { } The form is submitted, but of course we are sent to #fail this time. With an alert in the handler: var fn = function() { alert("omg!"); } The form is not submitted. This is awfully curious. With event.stop(), which is supposed to prevent the browser taking the default action: var fn = function(event) { event.stop(); } We are sent to #fail. So alert() is more effective at preventing a submission than event.stop(). What gives? I'm using Firefox 3.6.3 and Prototype 1.6.0.3. This behaviour also appears in Prototype 1.6.1.

    Read the article

  • Project management and bundling dependencies

    - by Joshua
    I've been looking for ways to learn about the right way to manage a software project, and I've stumbled upon the following blog post. I've learned some of the things mentioned the hard way, others make sense, and yet others are still unclear to me. To sum up, the author lists a bunch of features of a project and how much those features contribute to a project's 'suckiness' for a lack of a better term. You can find the full article here: http://spot.livejournal.com/308370.html In particular, I don't understand the author's stance on bundling dependencies with your project. These are: == Bundling == Your source only comes with other code projects that it depends on [ +20 points of FAIL ] Why is this a problem, (especially given the last point)? If your source code cannot be built without first building the bundled code bits [ +10 points of FAIL ] Doesn't this necessarily have to be the case for software built against 3rd party libs? Your code needs that other code to be compiled into its library before the linker can work? If you have modified those other bundled code bits [ +40 points of FAIL ] If this is necessary for your project, then it naturally follows that you've bundled said code with yours. If you want to customize a build of some lib,say WxWidgets, you'll have to edit that projects build scripts to bulid the library that you want. Subsequently, you'll have to publish those changes to people who wish to build your code, so why not use a high level make script with the params already written in, and distribute that? Furthermore, (especially in a windows env) if your code base is dependent on a particular version of a lib (that you also need to custom compile for your project) wouldn't it be easier to give the user the code yourself (because in this case, it is unlikely that the user will already have the correct version installed)? So how would you respond to these comments, and what points may I be failing to take into consideration? Would you agree or disagree with the author's take (or mine), and why?

    Read the article

  • Problem: writing parameter values to data driven MSTEST output

    - by Shubh
    Hi, I am trying to extract some information about the parameter variants used in an MSTEST data driven test case from trx file. Currently, For data driven tests, I get the output of same testcase with different inputs as a sequence of tags , but there is no info about the value of the variants. Example: Suppose we have a [data driven]TestMethod1() and the data rows contain variations a and b. There are two variations a=1,b=2 for which the test passes and a=3,b=4 for which the test fails. If we can output the info that it was a=1,b=2 which passed and a=3 b=4 which failed in the trx file; the output will be meaningful. Better information about test case runs from the output file alone(without any dependencies). Investigating the test failure without rerunning the whole set If the data rows change in data source(now a=1,b=2 pass and a=5,b=6 fail) , easy to decipher that the errors are different; although the fail sequence is still the same(row 0 pass row 1 fail but now row1 is different) Has any of you gone through a similar problem? What did you follow? I tried to put the parameter value information in the Description attribute of TestMethod, it didnt work. Any other methods you think can work too? thanks, Shubhankar

    Read the article

  • Maven Cobertura: unit test failed but build success

    - by Pavel Drobushevich
    Hi all, I've configured cobertura code coverage in my pom: <plugin> <groupId>org.codehaus.mojo</groupId> <artifactId>cobertura-maven-plugin</artifactId> <version>2.4</version> <configuration> <instrumentation> <excludes> <exclude>**/*Exception.class</exclude> </excludes> </instrumentation> <formats> <format>xml</format> <format>html</format> </formats> </configuration> </plugin> And start test by following command: mvn clean cobertura:cobertura But if one of unit test fail Cobertura only log this information and doesn't mark build fail. Tests run: 287, Failures: 1, Errors: 1, Skipped: 0 Flushing results... Flushing results done Cobertura: Loaded information on 139 classes. Cobertura: Saved information on 139 classes. [ERROR] There are test failures. ................................. [INFO] BUILD SUCCESS How to configure Cobertura marks build failed in one of unit test fail? Thanks in advance.

    Read the article

  • How to Return Variable for all tests to use Unittest

    - by chrissygormley
    Hello, I have a Python script and I am trying to set a variable so that if the first test fail's the rest of then will be set to fail. The script I have so far is: class Tests(): def function: result function.......... def errorHandle(self): return self.error def sudsPass(self): try: result = self.client.service.GetStreamUri(self.stream, self.token) except suds.WebFault, e: assert False except Exception, e: pass finally: if 'result' in locals(): self.error = True self.errorHandle() assert True else: self.error = False self.errorHandle() assert False def sudsFail(self): try: result = self.client.service.GetStreamUri(self.stream, self.token) except suds.WebFault, e: assert False except Exception, e: pass finally: if 'result' in locals() or self.error == False: assert False else: assert True class GetStreamUri(TestGetStreamUri): def runTest(self): self.sudsPass() class GetStreamUriProtocolFail(TestGetStreamUri): def runTest(self): self.stream.Transport.Protocol = "NoValue" self.errorHandle() self.sudsFail() if __name__ == '__main__': unittest.main() I am trying to get self.error to be set to False if the first test fail. I understand that it is being set in another test but I was hoping someone could help me find a solution to this problem using some other means. Thanks PS. Please ignore the strange tests. There is a problem with the error handling at the moment.

    Read the article

  • jQuery AJAX chained calls + Celery in Django

    - by user1029968
    Currently clicking one of the links in my application, triggers AJAX call (GET) that - if succeeds - triggers the second one and this second one - if succeeds - calls the third one. This way user can be informed which part of process started when clicking the link is currently ongoing. So in the template file in Django project, click callback body for link mentioned looks like below: $("#the-link").click(function(item)) { // CALL 1 $.ajax({ url: {% url ajax_call_1 %}, data: { // something } }) .done(function(call1Result) { // CALL 2 $.ajax({ url: {% url ajax_call_1 %}, data: { // call1Result passed here to CALL 2 } }) .done(function(call2Result) { // CALL 3 $.ajax({ url: {%url ajax_call_3 %}, data: { // call2Result passed here to CALL 3 } }) .done(function(call3Result) { // expected result if everything went fine console.log("wow, it worked!"); console.log(call3Result); }) .fail(function(errorObject) { console.log("call3 failed"); console.log(errorObject); } }) .fail(function(errorObject)) { console.log("call2 failed"); console.log(errorObject); } }) .fail(function(errorObject) { console.log("call1 failed"); console.log(errorObject); }); }); This works fine for me. The thing is, I'd like to prevent interrupting the following calls if the user closes the browser and the calls are not finished (as it will take some time to finish all three), as there is some additional logic in Django view functions called in each GET request. For example, if user clicks the link and closes the browser during CALL 1, is it possible to somehow go on with the following CALL 2 and CALL 3? I know that normally I'd be able to use Celery Task to process the function but is it still possible here with the chained calls mentioned? Any help is much appreciated!

    Read the article

  • i see the file but when i open it nothing is in it in c++ i/o stream and dont know why

    - by user320950
    #include<iostream> #include<fstream> #include<cstdlib> #include<iomanip> using namespace std; int main() { ifstream in_stream; // reads ITEMSLIST.txt ofstream out_stream1; // writes in listWititems.txt ifstream in_stream2; // reads PRICELIST.txt ofstream out_stream3;// writes in listWitprices.txt ifstream in_stream4;// read display.txt ofstream out_stream5;// write showitems.txt double p1=0.0,p2=0.0; int wrong=0; int count =0; char next; in_stream.open("ITEMLIST.txt", ios::in); // list of avaliable items /*if( in_stream.fail() )// check to see if itemlist.txt is open { wrong++; // counts number of errors cout << " the error occured here0, you have " << wrong++ << " errors" << endl; cout << "Error opening the file\n" << endl; exit(1); } else{ cout << " System ran correctly " << endl; } */ out_stream1.open("listWititems.txt", ios::out); // list of avaliable items /* if( out_stream1.fail() )// check to see if itemlist.txt is open { wrong++; cout << " the error occured here0, you have " << wrong++ << " errors" << endl; cout << "Error opening the file\n" << endl; exit(1); } else{ cout << " System ran correctly " << endl; } */ in_stream2.open("PRICELIST.txt", ios::in); /*if( in_stream2.fail() )// check to see if itemlist.txt is open { wrong++; cout << " the error occured here0, you have " << wrong++ << " errors" << endl; cout << "Error opening the file\n" << endl; exit(1); } else{ cout << " System ran correctly " << endl; } */ out_stream3.open("listWitdollars.txt", ios::out); /*if( out_stream3.fail() )// check to see if itemlist.txt is open { wrong++; cout << " the error occured here0, you have " << wrong++ << " errors" << endl; cout << "Error opening the file\n" << endl; exit(1); } else{ cout << " System ran correctly " << endl; } */ in_stream4.open("display.txt", ios::in); /*if( in_stream4.fail() )// check to see if itemlist.txt is open { wrong++; cout << " the error occured here0, you have " << wrong++ << " errors" << endl; cout << "Error opening the file\n" << endl; exit(1); } else{ cout << " System ran correctly " << endl; } */ out_stream5.open("showitems.txt", ios::out); /*if( out_stream5.fail() )// check to see if itemlist.txt is open { wrong++; cout << " the error occured here0, you have " << wrong++ << " errors" << endl; cout << "Error opening the file\n" << endl; exit(1); } else{ cout << " System ran correctly " << endl; }*/ in_stream.setf(ios::fixed); while(!in_stream.eof()) // reads to end of file and gets p1 which is itemnum, clears and gets next character { in_stream >> p1; cin.clear(); cin >> next; } out_stream1.setf(ios::fixed); while (!out_stream1.eof()) { out_stream1 << p1; cin.clear(); cin >> next; } in_stream2.setf(ios::fixed); in_stream2.setf(ios::showpoint); in_stream2.precision(2); while(!in_stream2.eof()) // reads file to end of file { in_stream2 >> p1 >> p2 >> count; // gets p1,p2, and count which is current total in_stream2 >> p2; p1 += p2; p2++; cin.clear(); // allows more reading cin >> next; return p1, p2; } out_stream3.setf(ios::fixed); out_stream3.setf(ios::showpoint); out_stream3.precision(2); while(!out_stream3.eof()) // reads file to end of file { out_stream3 << p1 << p2 << count; out_stream3 << p2; p1 += p2; p2++; cin.clear(); // allows more reading cin >> next; return p1, p2; } in_stream4.setf(ios::fixed); in_stream4.setf(ios::showpoint); in_stream4.precision(2); while (!in_stream4.eof()) { in_stream4 >> p1 >> p2 >> count; cin.clear(); cin >> next; } out_stream5.setf(ios::fixed); out_stream5.setf(ios::showpoint); out_stream5.precision(2); out_stream5 <<setw(5)<< " itemnum " <<setw(5)<<" price "<<setw(5)<<" curr_total " <<endl; // sends items and prices to receipt.txt out_stream5 << setw(5) << p1 << setw(5) <<p2 << setw(5)<< count; // sends items and prices to receipt.txt out_stream5 << " You have a total of " << wrong++ << " errors " << endl; in_stream.close(); // closing files. out_stream1.close(); in_stream2.close(); out_stream3.close(); in_stream4.close(); out_stream5.close(); system("pause"); }

    Read the article

  • How to efficiently resize an array of values, without boxing, used within a Dictionary<string, float[]>

    - by makerofthings7
    In the code below, Pages is defined as public SortedDictionary<DateTime, float[]> Pages { get; set; } I am trying to dynamically increase the size of this array. Can anyone tell how to increase the sized of the innermost float[]? var tt = currentContainer.Pages[dateTime]; Array.Resize<float>(ref tt, currentContainer.Pages.Count + 1); Fail 1 I tried the following code and get index out of range exception SortedDictionary<DateTime, float[]> Pages = new SortedDictionary<DateTime,float[]>(); float[] xx = new float[1]; xx[0] = 1; DateTime tempTime = DateTime.UtcNow; Pages.Add(tempTime, xx); var tt = Pages[tempTime]; Array.Resize<float>(ref tt, Pages.Count + 1); Pages[tempTime][1] = 2; Fail 2 The following gives a compile time error (property, index, or dynamic member can't be used as a ref value) SortedDictionary<DateTime, float[]> Pages = new SortedDictionary<DateTime,float[]>(); float[] xx = new float[1]; xx[0] = 1; DateTime tempTime = DateTime.UtcNow; Pages.Add(tempTime, xx); var tt = Pages[tempTime]; // The line below is different from Fail 1 above ... compile time error Array.Resize<float>(ref Pages[tempTime], Pages.Count + 1); Pages[tempTime][1] = 2; Question What is the most performant answer to resize this array? Would the answer change if it's likely that the final size will be 100-200 floats or 700-900 floats? What if I change my allocation size from +1 to +128? .. or larger?

    Read the article

  • Parallel prologue and epilogue in Grid Engine

    - by ajdecon
    We have a cluster being used to run MPI jobs for a customer. Previously this cluster used Torque as the scheduler, but we are transitioning to Grid Engine 6.2u5 (for some other features). Unfortunately, we are having trouble duplicating some of our maintenance scripts in the Grid Engine environment. In Torque, we have a prologue.parallel script which is used to carry out an automated health-check on the node. If this script returns a fail condition, Torque will helpfully offline the node and re-queue the job to use a different group of nodes. In Grid Engine, however, the queue "prolog" only runs on the head node of the job. We can manually run our prologue script from the startmpi.sh initialization script, for the mpi parallel environment; but I can't figure out how to detect a fail condition and carry out the same "mark offline and requeue" procedure. Any suggestions?

    Read the article

  • WD1000FYPS harddrive is marked 0 mb in 3ware (and no SMART)

    - by osgx
    After reboot my SATA 1TB WD1000FYPS (previously is was "Drive error") is marked 0 mb in 3ware web gui. Complete message: Available Drives (Controller ID 0) Port 1 WDC WD1000FYPS-01ZKB0 0.00 MB NOT SUPPORTED [Remove Drive] SMART gives me only Device Model and ATA protocol version 1 (not 7-8 as it must be for SATA) What does it mean? Just before reboot, when is was marked only with "Device Error", smart was: Device Model: WDC WD1000FYPS-01ZKB0 Serial Number: WD-WCASJ1130*** Firmware Version: 02.01B01 User Capacity: 1,000,204,886,016 bytes Device is: Not in smartctl database [for details use: -P showall] ATA Version is: 8 ATA Standard is: Exact ATA specification draft version not indicated Local Time is: Sun Mar 7 18:47:35 2010 MSK SMART support is: Available - device has SMART capability. SMART support is: Enabled SMART overall-health self-assessment test result: PASSED SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000f 200 200 051 Pre-fail Always - 0 3 Spin_Up_Time 0x0003 188 186 021 Pre-fail Always - 7591 4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 229 5 Reallocated_Sector_Ct 0x0033 199 199 140 Pre-fail Always - 3 7 Seek_Error_Rate 0x000e 193 193 000 Old_age Always - 125 9 Power_On_Hours 0x0032 078 078 000 Old_age Always - 16615 10 Spin_Retry_Count 0x0012 100 100 000 Old_age Always - 0 11 Calibration_Retry_Count 0x0012 100 253 000 Old_age Always - 0 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 77 192 Power-Off_Retract_Count 0x0032 198 198 000 Old_age Always - 1564 193 Load_Cycle_Count 0x0032 146 146 000 Old_age Always - 164824 194 Temperature_Celsius 0x0022 117 100 000 Old_age Always - 35 196 Reallocated_Event_Count 0x0032 199 199 000 Old_age Always - 1 197 Current_Pending_Sector 0x0012 200 200 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0010 200 200 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0 200 Multi_Zone_Error_Rate 0x0008 200 200 000 Old_age Offline - 0 What can be wrong with he? Can it be restored? PS new smart is === START OF INFORMATION SECTION === Device Model: WDC WD1000FYPS-01ZKB0 Serial Number: [No Information Found] Firmware Version: [No Information Found] Device is: Not in smartctl database [for details use: -P showall] ATA Version is: 1 ATA Standard is: Exact ATA specification draft version not indicated Local Time is: Mon Mar 8 00:29:44 2010 MSK SMART is only available in ATA Version 3 Revision 3 or greater. We will try to proceed in spite of this. SMART support is: Ambiguous - ATA IDENTIFY DEVICE words 82-83 don't show if SMART supported. Checking for SMART support by trying SMART ENABLE command. Command failed, ata.status=(0x00), ata.command=(0x51), ata.flags=(0x01) Error SMART Enable failed: Input/output error SMART ENABLE failed - this establishes that this device lacks SMART functionality. A mandatory SMART command failed: exiting. To continue, add one or more '-T permissive' options. PPS There was a rapid grow of " 192 Power-Off_Retract_Count " before dying. The hard was used in raid, with several hards from the same fabric packaging box (close id's). The hard drives were placed identically. Rapid means almost linear grow from 300 to 1700 in 6-7 hours. Maximal temperature was 41C. (thanks to munin's smart monitoring)

    Read the article

  • Best way to replicate / mirror 100s of databases in SQL 2005

    - by mrwayne
    Hi, I currently host around 400-500 SQL 2005 databases of varying sizes (1-10 gig) each. I am aware of most of the different methods available and the general pros/cons of mirroring, log shipping, replication and clustering, but i am not aware of how well they tend to perform when its employed at the size i have specified (400-500 unique databases). Does anyone have any good advice on what is likely the best method for having the ability to fail over to another server with this sort of setup? Fail over does not need to be immediate, i'm just looking for something better than taking backups every day and moving them to storage. I'm preferably looking for something that would also makes it easy to manage the databases in bulk (as opposed to one at a time). Thanks for your input!

    Read the article

  • linux ssh -X graphical applications will not start when system load is high

    - by Chrisv
    So I am using ssh -X to access a server. I am at a Xubuntu desktop accessing a Ubuntu server that is in the next room. Usually everything works fine, but when the system load gets high, any graphical applications I have freeze and fail to be restarted. This happens even if the process that is causing the high load has been niced to a low priority with "nice -n 19". And even though the system load is high, the command line works fine with no delay, and other applications I have running on the server (e.g. virtual machines) run fine. But any graphical application running through X dies. When the graphical applications fail they usually give out an error message that suggests a time-out. It seems that something connected to X has a low priority and times out. But what is it, and how does one fix it?

    Read the article

  • Why isn't sox able to convert to mp3?

    - by marue
    I installed Sox, i installed lame-398, but sox is not able to convert any file to mp3. It fails with the messages: ./../sox FAIL util: Unable to load LAME encoder library (libmp3lame). ./../sox FAIL formats: can't open output file `funktech.mp3': How can i check if lame has been installed correct? How can i get sox to find the mp3Library? edit: I did not install sox at all, it works without installing directly from the commandline. Lame was installed by following the instructions on their site: ./configure make make install which results in the following files being found in /usr/local/lib/ : libmp3lame.dylib, libmp3lame.la, libmp3lame.a Maybe symlinking libmp3lame.la, which is marked as executable, to /usr/bin would help?

    Read the article

  • DVD Drive Failing on Windows 7

    - by Seth Spearman
    Hello, I have x64 Windows 7 running on an ASUS M50VM. The DVD drive works completely unreliably if not at all. But the story is not that simple so bear with me...here are the gory details. When I first got the machine it came with Windows XP and I upgraded it to Windows Vista X64 and the DVD worked fine. When Windows 7 RC2 came out I tried it on a Virtual Machine and I liked it so much that I upgraded the machine to Win7 RC1. The DVD worked fine. Of course, RC1 was going to start spontaneously rebooting, so when Windows 7 was released I DID A CLEAN INSTALL of Windows 7. Just to clarify...by clean install I mean I did a FORMAT of the HARD DRIVE and INSTALLED it from scratch. EVER since then the DVD mostly doesn't work. I can sometime read from disk but that will often hang. (Please see my description below of HANG for details.) CD or DVD writes ALWAYS fail with a HANG (I have done a successful write only one time.) Here is what I mean by HANG... *Explorer Window is unresponsive. *Any software accessing the DVD drive is unresponsive. *The DVD tray will not eject. *Using a paper clip will eject but the disk is usually spinning real hard. *Attempting to shut down windows will fail. I have waited as long as ten minutes but the whole OS seems to hang. I do a hard shutdown. *Sometimes accessing the DVD (when it does not cause a HANG) will still fail and the device will actually seem to disappear from the system until I reboot. A couple of other things. It is NOT a hardware failure. It is the Windows OS. I know this because I swapped out my DVD drive with a friend with the same model...his machine is fine (he is still running Vista X64) and my machine still fails. For what it is worth. I swapped out my primary disk with the INTEL 160GB SSD. EDIT Here is what System Information shows about my DVD drive Drive D: Description CD-ROM Drive Media Loaded No Media Type DVD Writer Name HL-DT-ST DVDRAM GSA-T50N ATA Device Manufacturer (Standard CD-ROM drives) Status OK Transfer Rate -1.00 kbytes/sec SCSI Target ID 0 PNP Device ID IDE\CDROMHL-DT-ST_DVDRAM_GSA-T50N________________RR04____\5&2B5B7F1D&0&1.0.0 Driver c:\windows\system32\drivers\cdrom.sys (6.1.7600.16385, 144.00 KB (147,456 bytes), 7/13/2009 7:19 PM) Any ideas? HELP! Seth B Spearman

    Read the article

  • DVD Drive Failing on Windows 7

    - by Seth Spearman
    I have x64 Windows 7 running on an ASUS M50VM. The DVD drive works completely unreliably if not at all. But the story is not that simple so bear with me...here are the gory details. When I first got the machine it came with Windows XP and I upgraded it to Windows Vista X64 and the DVD worked fine. When Windows 7 RC2 came out I tried it on a Virtual Machine and I liked it so much that I upgraded the machine to Win7 RC1. The DVD worked fine. Of course, RC1 was going to start spontaneously rebooting, so when Windows 7 was released I DID A CLEAN INSTALL of Windows 7. Just to clarify...by clean install I mean I did a FORMAT of the HARD DRIVE and INSTALLED it from scratch. EVER since then the DVD mostly doesn't work. I can sometime read from disk but that will often hang. (Please see my description below of HANG for details.) CD or DVD writes ALWAYS fail with a HANG (I have done a successful write only one time.) Here is what I mean by HANG... *Explorer Window is unresponsive. *Any software accessing the DVD drive is unresponsive. *The DVD tray will not eject. *Using a paper clip will eject but the disk is usually spinning real hard. *Attempting to shut down windows will fail. I have waited as long as ten minutes but the whole OS seems to hang. I do a hard shutdown. *Sometimes accessing the DVD (when it does not cause a HANG) will still fail and the device will actually seem to disappear from the system until I reboot. A couple of other things. It is NOT a hardware failure. It is the Windows OS. I know this because I swapped out my DVD drive with a friend with the same model...his machine is fine (he is still running Vista X64) and my machine still fails. For what it is worth. I swapped out my primary disk with the INTEL 160GB SSD. EDIT Here is what System Information shows about my DVD drive Drive D: Description CD-ROM Drive Media Loaded No Media Type DVD Writer Name HL-DT-ST DVDRAM GSA-T50N ATA Device Manufacturer (Standard CD-ROM drives) Status OK Transfer Rate -1.00 kbytes/sec SCSI Target ID 0 PNP Device ID IDE\CDROMHL-DT-ST_DVDRAM_GSA-T50N________________RR04____\5&2B5B7F1D&0&1.0.0 Driver c:\windows\system32\drivers\cdrom.sys (6.1.7600.16385, 144.00 KB (147,456 bytes), 7/13/2009 7:19 PM) Any ideas? HELP! Seth B Spearman

    Read the article

  • Why isn't sox able to convert to mp3?

    - by marue
    I installed Sox, i installed lame-398, but sox is not able to convert any file to mp3. It fails with the messages: ./../sox FAIL util: Unable to load LAME encoder library (libmp3lame). ./../sox FAIL formats: can't open output file `funktech.mp3': How can i check if lame has been installed correct? How can i get sox to find the mp3Library? edit: I did not install sox at all, it works without installing directly from the commandline. Lame was installed by following the instructions on their site: ./configure make make install which results in the following files being found in /usr/local/lib/ : libmp3lame.dylib, libmp3lame.la, libmp3lame.a Maybe symlinking libmp3lame.la, which is marked as executable, to /usr/bin would help?

    Read the article

  • SQL Server: Is it possible to prevent SQL Agent from failing a step on error?

    - by franklinkj
    I have a stored procedure that runs custom backups for around 60 SQL servers (mixes 2000 through 2008R2). Occasionally, due to issues outside of my control (backup device inaccessible, network error, etc.) an individual backup on one or two databases will fail. This causes this entire step to fail, which means any subsequent backup commands are not executed and half of the databases on a given server may not be backed up. On the 2005+ boxes I am using TRY/CATCH blocks to manage these problems and continue backing up the remaining databases. On a 2000 server however, for example, I have no way to prevent this error from failing the entire step: Msg 3201, Level 16, State 1, Line 1 Cannot open backup device 'db-diff(\PATH\DB-DIFF-03-16-2010.DIF)'. Operating system error 5(Access is denied.). Msg 3013, Level 16, State 1, Line 1 BACKUP DATABASE is terminating abnormally. I am simply asking if anything like this is possible in SQL 2000 or if I need to go in a completely different direction.

    Read the article

  • Exim - Sender verify failed - rejected RCPT

    - by Newtonx
    While checking on Exim's log messages I found many entries of the following message "Sender verify failed" "rejected RCPT" ... I 'm not an exim expert... I'm afraid Exim is not delivering 100% emails to recipients, because our Email Marketing Application its getting a lower OPEN RATE. Can someone helpe understand this log messages? Is it my server saying "No Such User Here" or a remote server? 174.111.111.11 represents my server IP. Thanks Exim log 2010-10-02 14:00:19 SMTP connection from myserverdomain.com.br () [174.111.111.11]:54514 I=[174.111.111.11]:25 closed by QUIT 2010-10-02 14:00:19 SMTP connection from [174.111.111.11]:54515 I=[174.111.111.11]:25 (TCP/IP connection count = 2) 2010-10-02 14:00:19 H=myserverdomain.com.br () [174.111.111.11]:54515 I=[174.111.111.11]:25 Warning: Sender rate 672.4 / 1h 2010-10-02 14:00:19 H=myserverdomain.com.br () [174.111.111.11]:54515 I=[174.111.111.11]:25 sender verify fail for <[email protected]>: No Such User Here 2010-10-02 14:00:19 H=myserverdomain.com.br () [174.111.111.11]:54515 I=[174.111.111.11]:25 F=<[email protected]> rejected RCPT <[email protected]>: Sender verify failed 2010-10-02 14:00:19 SMTP connection from myserverdomain.com.br () [174.111.111.11]:54515 I=[174.111.111.11]:25 closed by QUIT 2010-10-02 14:00:19 SMTP connection from [174.111.111.11]:54516 I=[174.111.111.11]:25 (TCP/IP connection count = 2) 2010-10-02 14:00:19 H=myserverdomain.com.br () [174.111.111.11]:54516 I=[174.111.111.11]:25 Warning: Sender rate 673.3 / 1h 2010-10-02 14:00:19 H=myserverdomain.com.br () [174.111.111.11]:54516 I=[174.111.111.11]:25 sender verify fail for <[email protected]>: No Such User Here 2010-10-02 14:00:19 H=myserverdomain.com.br () [174.111.111.11]:54516 I=[174.111.111.11]:25 F=<[email protected]> rejected RCPT <[email protected]>: Sender verify failed 2010-10-02 14:00:19 SMTP connection from myserverdomain.com.br () [174.111.111.11]:54516 I=[174.111.111.11]:25 closed by QUIT 2010-10-02 14:00:19 SMTP connection from [174.111.111.11]:54517 I=[174.111.111.11]:25 (TCP/IP connection count = 2) 2010-10-02 14:00:19 H=myserverdomain.com.br () [174.111.111.11]:54517 I=[174.111.111.11]:25 Warning: Sender rate 674.3 / 1h 2010-10-02 14:00:20 H=myserverdomain.com.br () [174.111.111.11]:54517 I=[174.111.111.11]:25 sender verify fail for <Luciene_souza_vasconcellos=hotmail.com--2723--bounce@e-mydomain.com.br>: No Such User Here 2010-10-02 14:00:20 H=myserverdomain.com.br () [174.111.111.11]:54517 I=[174.111.111.11]:25 F=<Luciene_souza_vasconcellos=hotmail.com--2723--bounce@e-mydomain.com.br> rejected RCPT <[email protected]>: Sender verify failed

    Read the article

  • Mercurial not receiving push

    - by Jeffrey04
    I have a mercurial web-frontend (hgwebdir.cgi) installed on a server, and an installation of nginx was installed in front of it as a reverse proxy to the web-frontend as my friend suggested. However, whenever a large changeset is pushed (via a script), it would fail. I found an issue ticket @google-code that describe similar problem, and there is a solution that says (#39) So the server side answer is: don't send the 401 back early. Be as slow/dumb as 'hg serve' and make the hg client send the bundle twice. How do I do that? My current nginx config location /repo/testdomain.com { rewrite ^(.*) http://bpj.kkr.gov.my$1/hgwebdir.cgi; } location /repo/testdomain.com/ { rewrite ^(.*) http://bpj.kkr.gov.my$1hgwebdir.cgi; } location /repo/testdomain.com/hgwebdir.cgi { proxy_pass http://localhost:81/repo/testdomain.com/hgwebdir.cgi; proxy_set_header Host $http_host; proxy_set_header X-Forwarded-For $proxy_add_x_forwarded_for; proxy_buffering on; client_max_body_size 4096M; proxy_read_timeout 30000; proxy_send_timeout 30000; } From the access log we keep seeing 408 entries incoming.ip.address - - [18/Nov/2009:08:29:31 +0800] "POST /repo/testdomain.com/hgwebdir.cgi/example_repository?cmd=unbundle&heads=73121b2b6159afc47cc3a028060902883d5b1e74 HTTP/1.1" 408 0 "-" "mercurial/proto-1.0" incoming.ip.address - - [18/Nov/2009:08:37:14 +0800] "POST /repo/testdomain.com/hgwebdir.cgi/example_repository?cmd=unbundle&heads=73121b2b6159afc47cc3a028060902883d5b1e74 HTTP/1.1" 408 0 "-" "mercurial/proto-1.0" Is there anything else I can do on the server because solving it on the server side is preferable :/ Further Findings Bitbucket seems to have this solved ( Check liquidhg bitbucket project and the Diagnosis wiki page ) on the server side, can't find the config anywhere though :/ What happens next varies depending on your server. Some servers refuse the BODY, simplying closing the pipe from the client and causing Mercurial to fail. Some, like Apache (at least the way I configure it, and that could be part of the problem) and nginx (they way BitBucket.org configures it), accept the BODY, though it may take a few retries. Bottom line: if Mercurial doesn't fail the push, it sends the changeset data at least once to a server that has already told it it lacks credentials (more on this at Blame). Assuming Mercurial is still running, it resends the "unbundle" request and data, this time with authentication. Finally, Apache accepts the data successfully. Nginx, OTOH, at least under BitBucket's configuration, seems to reassemble the previous body (the one that lacked authentication) and somehow keep Mercurial from re-sending the whole body.

    Read the article

  • Some sites won't load on Ubuntu/Mint

    - by Or W
    I have a REALLY weird problem with either my network or my OS. Last week I've suddenly had difficulties loading some websites or even more odd some parts of different websites. For example, I could load gmail.com, login and view the list of emails in my inbox but when I clicked one of them it would just time out. Another example is http://www.ynet.co.il, I can view the home page but going into any one of the articles fails (times out). I've tried Chrome, Firefox and Opera, all fail the same way. If I take a URL of a page I cannot load via the browser and try to wget it though the console I get the file just fine. I've formatted my machine (Used to run Ubuntu 13.04) and installed Mint Linux this time, it worked fine for a few days and now, again, having the same exact issues. Important to note that I have other machines connected either directly or via Wi-Fi to the router and they are all working fine (two win7 machines and 1 raspberry pi). Another strange behavior is that I can ftp or ssh to remote machines but cannot send files via ftp (times out) even if I set passive mode ON and when using ssh I can do just about anything but I cannot paste text into the remote machine, for example if I nano a file on the remote machine and try to paste anything from my clipboard it freezes. What I've tried so far: Disable IPv6 on the networking admin (and on firefox disabling ipv6 on the about:config page) Changing the port and the network cable I went to the store and bought a new standalone PCIe network adapter Connected my win7 laptop using the same cable and router port (sites that were not working on my Mint are working just fine on the win7 machine) Loaded Mint from a livecd, got the same result Tried changing the MTU (was 1500, tried 1492) Some observations: When I clear my browser cache and go to facebook.com for example, the homepage loads but I fail to load any profile/group page. If I refresh facebook.com homepage a couple of times it stops and fails to load until I clear my browser cache. I changed the chrome cache folder permissions to 0777 but that did not help. When I run netstat -n I see A LOT of connections that are in 'FIN_WAIT' mode (I'm guessing that's when I try to refresh pages that are not working and timing out), I have no idea what it means or if it helps anyone figure out what's wrong. The sites that are not loading correctly are always that same, they don't vary or anything and they fail to load exactly the same way on all three browsers that I've tried. When I Googled 'Ubuntu some sites not loading' I see a huge amount of complaints just like mine, but none of them that I could find actually says what the problem is or how they fixed it. Technical stuff: netstat -n ps aux netstat -nr

    Read the article

  • Apache doesn't autostart because vpn isn't up yet.

    - by Col. Shrapnel
    I have a FreeBSD8 server, and VPN connection to my ISP. I use mpd5 and it works fine. A have an Apache server whch works fine, if I start it manually, after VPN is get up. But when I add it to rc.conf autostart, it fail to start, saying (49) can't assign requested address: make_sock could not bind to address I suppose it's because VPN isn't up yet and no IP address assigned to the interface which i set in the Listen directive in the httpd.conf. If i set Listen to the existing 127.0.0.1, it fail to serve wan requests. Is there a solution, either to delay apache autostart or configure it some different?

    Read the article

  • Force failover a Cisco ASA

    - by user974896
    I have two ASA in a lan state primary\secondary configuration. None of them have "failover active" or "no failover active" in their configuration. Would it be proper to failover in a manner such as: Log into console of primary unit and issue "failover lan state secondary", log into the console of the original secondary unit and issue "failover lan state primary". To fail back simply reverse the process or Log into the console of the primary unit and issue "no failover active", log into the console of the original secondary unit and issue "failover active". To fail back issue "failover active" on the original primary (now secondary) unit, and "no failover active" on the now primary unit. I do not like the second method because it adds configuration directives that were not in place before. Will the first method work?

    Read the article

  • Is there a program that compares image files and reports if they are exactly the same pixel-wise?

    - by Nathaniel Drake
    I'm making a regression testing suite for some rendering software. I need to be able to load an image file (PNG or TGA, ideally) and compare the pixel values to a standard approved image. I'd like it to be command line driven too, so I can make a batch file to run all the tests. All the compare utilities I have found so far either show differences (I just need it to fail if they are different) or compare all the bytes, meaning that meta-data will trigger a fail. Anyone got any suggestions? I am not a coder, and can only barely cobble a batch script together. Thanks for any suggestions.

    Read the article

  • SCCM SP2 - OOB Management Certificates Problems

    - by Achinoam
    Hi experts, I have a vPro client computer with AMT 4.0. It was importeed successfully via the Import OOB Computers wizard, and after sending a "Hello- packet" it became provisioned. (The SCCM GUI displays AMT Status: Provisioned). But when I try to perform power operations on this machine, they always fail with the following lines in the log: AMT Operation Worker: Wakes up to process instruction files 7/29/2009 10:59:29 AM 2176 (0x0880) AMT Operation Worker: Wait 20 seconds... 7/29/2009 10:59:29 AM 2176 (0x0880) Auto-worker Thread Pool: Work thread 3884 started 7/29/2009 10:59:29 AM 3884 (0x0F2C) session params : https:/ / amt4.domaindemo.com:16993 , 11001 7/29/2009 10:59:29 AM 3884 (0x0F2C) ERROR: Invoke(invoke) failed: 80020009argNum = 0 7/29/2009 10:59:31 AM 3884 (0x0F2C) Description: A security error occurred 7/29/2009 10:59:31 AM 3884 (0x0F2C) Error: Failed to Invoke CIM_BootConfigSetting::ChangeBootOrder_INPUT action. 7/29/2009 10:59:31 AM 3884 (0x0F2C) AMT Operation Worker: AMT machine amt4.domaindemo.com can't be waken up. Error code: 0x80072F8F 7/29/2009 10:59:31 AM 3884 (0x0F2C) Auto-worker Thread Pool: Warning, Failed to run task this time. Will retry(1) it 7/29/2009 10:59:31 AM 3884 (0x0F2C) After investigation, I've seen that the problem occurs already on the 2nd stage of the provisioning: Start 2nd stage provision on AMT device amt4.domaindemo.com. 8/2/2009 4:55:12 PM 2944 (0x0B80) session params : https: / / amt4.domaindemo.com:16993 , 11001 8/2/2009 4:55:12 PM 2944 (0x0B80) Delete existing ACLs... 8/2/2009 4:55:12 PM 2944 (0x0B80) ERROR: Invoke(invoke) failed: 80020009argNum = 0 8/2/2009 4:55:14 PM 2944 (0x0B80) Description: A security error occurred 8/2/2009 4:55:14 PM 2944 (0x0B80) Error: Cannot Enumerate User Acl Entries. 8/2/2009 4:55:14 PM 2944 (0x0B80) Error: CSMSAMTProvTask::StartProvision Fail to call AMTWSManUtilities::DeleteACLs 8/2/2009 4:55:14 PM 2944 (0x0B80) Error: Can not finish WSMAN call with target device. 1. Check if there is a winhttp proxy to block connection. 2. Service point is trying to establish connection with wireless IP address of AMT firmware but wireless management has NOT enabled yet. AMT firmware doesn't support provision through wireless connection. 3. For greater than 3.x AMT, there is a known issue in AMT firmware that WSMAN will fail with FQDN longer than 44 bytes. (MachineId = 17) 8/2/2009 4:55:14 PM 2944 (0x0B80) STATMSG: ID=7208 SEV=E LEV=M SOURCE="SMS Server" COMP="SMS_AMT_OPERATION_MANAGER" SYS=JE-DEV-MS0 SITE=JR1 PID=1756 TID=2944 GMTDATE=Sun Aug 02 14:55:14.281 2009 ISTR0="amt4.domaindemo.com" ISTR1="amt4.domaindemo.com" ISTR2="" ISTR3="" ISTR4="" ISTR5="" ISTR6="" ISTR7="" ISTR8="" ISTR9="" NUMATTRS=0 8/2/2009 4:55:14 PM 2944 (0x0B80) This error is consistent with all the other 2nd stage provisioning tasks. (Add ACLs, Enable Web UI, etc.) I've opened the certification authority, and I see that the certificates were issued to the SCCM Site server instead of the AMT client! What could be the reason for this failure? What is the problematic definition for the certificate? Thank you in advance!!!

    Read the article

  • Network adapters reliability

    - by casey_miller
    Can you help me with understanding of reliability of network adapters. Most of the time servers do have at least 2 NIC's bonded to provide sort of a HA for it. So in case of one NIC fails, the second would still do the job. I wonder which factors work when you use network adapters. I know that, the most important and weakest part of any computer system is: storage (i.e HDD). but how reliable actually network adapters are? There are more expensive ones, and cheaper adapters. In which cases do they actually fail? In what circumstances. May it be a intensive usage of them Time when it's on In your experience how often you found yourself changing NIC's due to their fail? Or just what's the typical lifetime of commodity NIC's? thanks.

    Read the article