Search Results

Search found 8673 results on 347 pages for 'kvm switch'.

Page 264/347 | < Previous Page | 260 261 262 263 264 265 266 267 268 269 270 271  | Next Page >

  • One Windows Domain workstation can ping gateway but gets no internet access

    - by dindeman
    One of the (Windows XP SP3) workstations of our Windows Domain could not access internet anymore, this problem suddenly happened overnight. The domain controllers (there are three of them) are all running Windows Server 2008. First I compared the output of ipconfig /all on the faulty workstation with the output of a working workstation and it was just fine as it had always been. In particular the default gateway was correct and always remained pingable from the faulty workstation. I guessed that something was wrong with the DHCP service and I restarted the DHCP server service on all of our three DCs as well as the DHCP client service on the faulty workstation. This didn't solve the issue. I then thought of renewing the DHCP lease with ipconfig /release and ipconfig /renew and here is my first question: why did this never work? The same IP address (192.168.0.45) kept being assigned despite all my attempts to renew it (note that all our workstation are getting their TCP/IP automatically.) Even by leaving the domain and changing the computer name the same address was yet again obtained... Anyway I then proceeded to switch the TCP/IP configuration for that machine manually to another free valid IP address (192.168.0.41)... and then the internet access came back! I then cleared any traces of the previous IP in the DHCP leases list and in the DNS tables of our DCs and, after setting back the TCP/IP configuration to 'automatic', finally, the new lease would be granted (192.168.0.41) alongside with the internet access. My second question: what went suddenly wrong with the original IP address?

    Read the article

  • Configuring two nearby WLANs: should I use the same ssid?

    - by Rory
    I'm configuring a home network for basic internet use (ie don't really need connectivity between workstations on the network). My brick walls mean a single wireless router doesn't provide good coverage throughout the house, so I have purchased two powerline adapters and now have the incoming modem/wireless router at one end of the house plugged into a powerline adapter, and at the other end of the house the other powerline adapter plugged into another wireless router. Currently the two wireless networks have different ssids. (The powerline adapters only do power-Ethernet; they're not wireless access points themselves.) This works well, except when I move between rooms and would ideally like my devices (iPad, phones, laptops) to switch from the weak to the strong signal. Sometimes there's enough signal that they hold on to the weak connects instead of switching to the strong one. Should I name the two networks the same ssid, and if so what is the actual effect? Do the signals get confused, is the bandwidth affected, will this help my devices seamlessly move from one to the other, or is the ssid just a cosmetic thing that actually doesn't have any impact on this situation? Are there any other settings that I should configure to make my setup optimal?

    Read the article

  • Shortcut To Full Screen App In Lion

    - by omghai2u
    I postponed getting OSX Lion for as long as I possibly could. Now that I have it, I'm having lots of difficulties getting it to perform how I want. On Snow Leopard my typical setup for working was 4 spaces. I'd keep a Windows VM open on Space #4 full-screened, a Linux open on space #3, and I'd do other stuff on spaces #1 and #2. My keyboard shortcut allowed me to switch between my Windows work (Command + 4) to my Linux work (Command + 3) very quickly, and without the need for my hands to leave the keyboard (or effectively to even quit typing). Productivity was good. I see that on Lion a full-screened VM (and yes, they need to be full screened, Fusion's Unity won't cut it for what I need to do) is its own separate Desktop. I have set up 4 desktops and made my keyboard shortcuts to move between them Command + # just as before. But how do I get my full-screened VM to be one of those already existing desktops? Or, rather, how do I make a short-cut for the full-screened app?

    Read the article

  • iptables rule on INPUT between 2 ethernet cards on the same host

    - by user1495181
    I have 2 eth cards on the same host. Both connected directly with LAN cable. I set eth0 with ip - 192.168.1.2 I set eth1 with ip - 192.168.1.1 I set this rule: iptables -A INPUT -p tcp -j NFQUEUE --queue-num 0 There are no other rules. (I ran iptables -X,-F) I send TCP syn packet ( with c++ program by using raw socket) from 192.168.1.2 to 192.168.1.1 In wireshark i see that the packet received on eth0, but the iptables rule (above) dosnt apply for this packet. when i sent the packet to remote host and apply this rule on the remote host than it work correct. So, i guess that this is due to the fact that both eth cards exists the same host. . I need to create iptables INPUT rule for local eth card (dest and src on the same machine ). I need it for simplify test. Did i guess the problem correct? is there a way to bypass this? Ps - connected them via switch didn't help. the rule wasn't applied. Run on Ubuntu. TCDUMP show the packet: 10:48:42.365002 IP 192.168.1.2.38550 > 192.168.1.1.34298: Flags [S], seq 0, win 5840, length 0 but logging of iptables like this, has nothing: iptables -A INPUT -p tcp -j LOG --log-prefix '*****************' iptables -A OUTPUT -p tcp -j LOG --log-prefix '#################'

    Read the article

  • Standing and sitting while using a computer at work

    - by Adam Batkin
    I would like to be able to comfortably switch between sitting and standing while at work (I'm a software developer, so I spend most of my day in front of a computer). For the past couple of months I have been using a large elevated stand that sits on my desk (designed expressly for this purpose) containing my keyboard and mouse, and my monitors have been raised as high as possible and aimed upwards. So I can stand all day and I'm pretty comfortable (my right wrist may be at too much of an angle when it's on my mouse, but that's a separate issue). The only problem is that sometimes I want to be able to sit. I can easily place my keyboard and mouse back down under the elevated stand, but I have to look up pretty steeply and that is uncomfortable and makes it difficult to see the screens since they are tilted upwards. My monitor mounts are difficult to adjust quickly/easily, so I can't just re-aim them. I would of course love one of those hydraulic standing/sitting desks (cost isn't the problem). But I'm in a row of "trader-style" desks where it's basically a very long surface with people sitting at 6-foot intervals. What type of equipment do you recommend? I suppose the best thing would be some sort of monitor stand (it must be able to hold 2-3 LCDs) that can easily be lowered and raised. But any other suggestions are also welcome.

    Read the article

  • disk write cache buffer and separate power supply

    - by HugoRune
    Windows has a setting to turn off the write-cache buffer (see image) Turn off Windows write-cache buffer flushing on the device To prevent data loss, do not select this check box unless the device has a separate power supply that allows the device to flush its buffer in case of power failure. Is it feasible and economical to get such a "separate power supply" for the internal sata drives of a non-server PC? Under what name is such a power supply sold? I know that there are UPS devices that can be connected to external drives,but what is required to be able to switch this setting safely on for an internal disk? The setting has different descriptions in different version of windows Windows XP: Enable write caching on the disk This setting enables write caching in Windows to improve disk performance, but a power outage or equipment failure might result in data loss or corruption. Windows Server 2003: Enable write caching on the disk Recommended only for disks with a backup power supply. This setting further improves disk performance, but it also increases the risk of data loss if the disk loses power. Windows Vista: Enable advanced performance Recommended only for disks with a backup power supply. This setting further improves disk performance, but it also increases the risk of data loss if the disk loses power. Windows 7 and 8: Turn off Windows write-cache buffer flushing on the device To prevent data loss, do not select this check box unless the device has a separate power supply that allows the device to flush its buffer in case of power failure. This article by Raymond Chen has some more detailed information about what the setting does.

    Read the article

  • How do I activate the F_LINE input in a transplanted HP chassis?

    - by admin
    I have an HP Pavilion Media Center PC chassis, vintage 2003 or so and I replaced the motherboard in it with a newer (vintage 2009) HP motherboard, M2N68-LA (Narra 5). I have scoured the internet trying to find pinouts for the motherboard to no avail. My question concerns the front panel audio, specifically Line In. The old chassis was built for AC97 but the new mobo is build for the newer HD audio standard. I figured out by comparison & experimentally how to connect the Mic & Headphone jacks to the HD audio header of the mobo by adding a manual switch to set the SENSE lines. Now all works fine for Mic & headphone. The old chassis also has a front panel Line In jack that the newer HP chassis does not have. However, the new mobo has a 4 pin white connector labeled F_LINE that I believe is a line input. Under Windows 7 I see the two Line Inputs in the mixer but I can't get one of them to become active. The 4 pin F_LINE connector uses the two middle pins for ground, and presumably the other two for left and right audio inputs. There are no pins for sensing on that connector. Can anyone tell me how to use that F_LINE input for the front panel, or how to activate it?

    Read the article

  • How can I make my Super keys (Windows Key) behave more like Ctrl/Alt/Shift in Linux

    - by deltaray
    After using the Ctrl + "arrow keys" for 13 years to switch virtual desktops in X windows, I've been convinced recently to change to using the Super keys instead (the windows key and the context menu key, which I've remapped). This all works fine for the most part. However, something is still picking up the key events that these keys are sending as if they are a normal alphanumeric like key. For example, I first noticed this in Google Docs spreadsheet that if I press the windows key alone over top of a cell, that it starts editing that cell. It doesn't insert anything, it just sends a key event that Firefox sees and starts editing the cell. This caused problems on a collaborative document I was working on as the way Google docs works, it led to me accidentally erasing the data in a few fields before I realised what was going on. I like using the super keys, but I want them to behave more like a Ctrl or Alt key does in that its a modifier key and doesn't send anything until a second key is pressed. My setup is the following: Ubuntu 10.10 XFCE 4 Microsoft Natural Ergo 4000 keyboard (with the logo scratched out) The following is my .Xmodmap file: remove Lock = Caps_Lock keycode 66 = Escape ! The below maps my other windows context menu key. keycode 135 = Super_R Edit: As requested, here is the relevant output from xev for a keypress and keyrelease of my Super_L (left windows key) KeyPress event, serial 34, synthetic NO, window 0x8200001, root 0x15d, subw 0x0, time 2428849342, (177,174), root:(182,228), state 0x10, keycode 133 (keysym 0xffeb, Super_L), same_screen YES, XLookupString gives 0 bytes: XmbLookupString gives 0 bytes: XFilterEvent returns: False KeyRelease event, serial 34, synthetic NO, window 0x8200001, root 0x15d, subw 0x0, time 2428849430, (177,174), root:(182,228), state 0x50, keycode 133 (keysym 0xffeb, Super_L), same_screen YES, XLookupString gives 0 bytes: XFilterEvent returns: False

    Read the article

  • Limited connections to Ubuntu 12.04 server

    - by Luis M. Valenzuela
    I'm having a weird problem with my server. The server is inside my network, connected to a 3com switch which is connected to the router that handles the internet connection. The main purpose of the server is to host a php application. What's happening is that user 1 to 15 in the private network have no problems connecting to the server, when user 16 tries to connect a time out comes out and is unable to connect to the server. It's not just to the php application, but to any service from the server. When the 15 users are using the application, the server doesn't even answer to ping. I haven't set any special limit in Apache's ini file or MySql and the firewall is being turned off because the server is only to give service to the internal network. Is there a parameter in any of the network's card conf. files that might me causing this ? Or should I suspect from the router's or switches configuration ? UPDATE. Tomorrow, I'm gonna do some test on the server modifying two kernel params in : /etc/sysctl.conf The settings are: net.core.somaxconn which has the limit on simultaneous network connections to the server and kernel.shmmax which controls the amount of memory the system can use for managing connections.

    Read the article

  • Out of memory errors but not actually out of memory...

    - by commradepolski
    So, myself and my fellow support techs have been fighting with this issue and we still dont know what the problem is. Lets start off with the system specs: Windows XP 32 bit Corporate (SP2 and SP3) Intel D975XBX2 Mobo 4gb of ram Intel Core 2 Quad Q6600 ATI Radeon HD 3600 - 512mb After a few hours of working on the machine, the end user will begin to see the following symptoms: Out of memory messages Title bars and menus dont draw in properly Problems accessing network resources Problems opening up documents such as MSWord and MSPowerpoint and text files Problems opening up explorer windows General instability We have looked at task manager while this issue was occurring, and all indicators, like PF usage, threads, handles, etc. are normal. We have been having trouble pinpointing the root cause of this issue. It is also not situated with one user, it affects 8-10. So far we have tried: Resetting CMOS (Waiting to see results) Replacing video card (didnt help) Windows updates (didnt help) Updating network drivers (didnt help) Switching user from 1gbps to 100mbps network connection (awaiting results) Swapping the affected user's hardware (waiting for results) Increasing desktop heap size (helped for a bit but then the issue became more frequent) Applying the /3 switch to XP (didnt help) Increasing and decreasing and setting PF to system managed state (didnt help) We did have a power outage at the office a couple weeks ago, and all these issues became more frequent. Prior to the power outage it may take a week or so for the users to experience the issues but since the power outage it takes 3-4 hours or less. We havent had reports of the above issues causing BSODs, although that would be easier to diagnose :). Any help is greatly appreciated.

    Read the article

  • Linux iptables / conntrack performance issue

    - by tim
    I have a test-setup in the lab with 4 machines: 2 old P4 machines (t1, t2) 1 Xeon 5420 DP 2.5 GHz 8 GB RAM (t3) Intel e1000 1 Xeon 5420 DP 2.5 GHz 8 GB RAM (t4) Intel e1000 to test linux firewall performance since we got bitten by a number of syn-flood attacks in the last months. All machines run Ubuntu 12.04 64bit. t1, t2, t3 are interconnected through an 1GB/s switch, t4 is connected to t3 via an extra interface. So t3 simulates the firewall, t4 is the target, t1,t2 play the attackers generating a packetstorm thorugh (192.168.4.199 is t4): hping3 -I eth1 --rand-source --syn --flood 192.168.4.199 -p 80 t4 drops all incoming packets to avoid confusion with gateways, performance issues of t4 etc. I watch the packet stats in iptraf. I have configured the firewall (t3) as follows: stock 3.2.0-31-generic #50-Ubuntu SMP kernel rhash_entries=33554432 as kernel parameter sysctl as follows: net.ipv4.ip_forward = 1 net.ipv4.route.gc_elasticity = 2 net.ipv4.route.gc_timeout = 1 net.ipv4.route.gc_interval = 5 net.ipv4.route.gc_min_interval_ms = 500 net.ipv4.route.gc_thresh = 2000000 net.ipv4.route.max_size = 20000000 (I have tweaked a lot to keep t3 running when t1+t2 are sending as many packets as possible). The result of this efforts are somewhat odd: t1+t2 manage to send each about 200k packets/s. t4 in the best case sees aroung 200k in total so half of the packets are lost. t3 is nearly unusable on console though packets are flowing through it (high numbers of soft-irqs) the route cache garbage collector is no way near to being predictable and in the default setting overwhelmed by very few packets/s (<50k packets/s) activating stateful iptables rules makes the packet rate arriving on t4 drop to around 100k packets/s, efectively losing more than 75% of the packets And this - here is my main concern - with two old P4 machines sending as many packets as they can - which means nearly everyone on the net should be capable of this. So here goes my question: Did I overlook some importand point in the config or in my test setup? Are there any alternatives for building firewall system especially on smp systems?

    Read the article

  • Bridging networks problems

    - by Eric
    In my setup I have 3 computers and 2 (wireless d-link) routers. Computer1 has ethernet and wireless interfaces ethernet : 192.168.0.x (DHCP) wireless : 192.168.10.254 (static) Computer 2 has ethernet with two ips ethernet1 : 192.168.0.90 (static) ethernet2 : 192.168.10.110 (static) Computer 3 is a particular device with a hardcoded ip that I can't change wireless : 192.168.10.41 (static) Router1 manages internet and DHCP for network 192.168.0.0/24 Router2 is more complicated. I don't use DHCP. I use it to bridge between both networks. Its static ip is 192.168.10.1 Computer1 can ping Computer2. Computer1 can ping Computer3. Computer1 can ping Router1. Computer1 cannot ping Router2. Computer2 cannot ping Computer3. Computer2 can ping Router2. Router1 can ping Router1 Router2 can ping Computer2 Router2 cannot ping Computer1 Router2 cannot ping Computer3 This is very weird. Router2 manages the wireless connection, it should be able to ping its own computers right? My question is obviously : How can I make it so Computer2 can access everything else. This is a traditional case of "it was working before christmas and now it doesn't". The ethernet wiring is as follow : [ Computer1 ]----[ Router1 ]---[ Router2 ]---[ Computer3 ] I am using switch (lan) ports on Router1/2.

    Read the article

  • MySQL Memory Limit Windows Server 2003

    - by Matt
    I am running MySQL 5.0.51a on Windows Server 2003 Standard Edition on an HP DL580 G4 with 3GB installed. One of my database tables has grown to 5.3 GB with an index file of 2.5 GB, which I believe is causing MySQL to be slow due to having to constantly load and unload the index file when updates are made to the table. The server itself seems to be performing OK because MySQL is only using about 500MB of memory (there are other apps running on the system, but MySQL uses the most memory). The table is fairly active with new records getting adding all during day but no deletes, ever. The MySQL server has up to 600 connections allowed, but only small number (10 or 20) would actually be writing to this table. I increased the memory limits in MySQL but since the max connections is so high I don't think I can give each connection 1GB without risking a problem. Is there some tuning that would let just certain connections get a lot of memory? So I have started to look for alternatives to avert the crisis I know is coming soon. Some of the options I have: Upgrade to Server 2003 Enterprise to install 64GB of memory. Question: would 32 bit MySQL be able to access more than 2GB? Would that be 2GB per thread? That would still be smaller than the index table size so it might not solve the problem completely, but it would be better than now. Upgrade to Server 200x 64 bit and MySQL 64 bit. Switch to a *nix 64 bit server. If anybody has suggestions for things to do in the meantime, opinions on which way to go, or other things that I have overlooked I would appreciate the help. Thanks

    Read the article

  • Dropbox picture sync: Skip RAW files?

    - by Steven Lu
    I like the convenience of having Dropbox keep track of my photos because it tends to work with my devices over 3G (I am often tethering to my phone with my iPad and Macbook) as well as Wifi, but it's a waste of network traffic to sync the raw files from my camera or memory card. It clutters up the dropbox list and the files are just huge. Is there a way to configure the Dropbox client so that it ignores a certain file extension for the picture sync? Also, I suspect that if I just go and delete the raw files, that the next time I plug in the memory card and tell Dropbox to sync, it will re-download the raw files. Which would be terribad. I could switch to iCloud for Photo Stream, I suppose, but there will be no access via 3G that way. And I've already got years of experience with Dropbox so I know it's going to just work. I think any method that works for filtering files to exclude from sync on Dropbox in general should work here too. Edit: Wow there are 19k votes for this exact request.

    Read the article

  • I need to build a mini computer lab with 6 PCs

    - by chiurox
    Hello everyone, This weekend I need to build a mini computer lab with 5-6 PCs. The purpose is for a small computer class that will be taking place. They're mostly going to be doing office and daily kind of stuff, so nothing high performance. However, I hope it will last at least for 2 more years. I already have some parts for 2 PCs, one is a P4 3.0 and another is Celeron 2.4GHz, both socket 478. For the other 4 PCs, I'm wondering if I should buy individual parts and put it all together or get workstations like those Dell Optiplex with P4s. To put things into perspective, I am not currently in the US. I'm in South America and prices here are ridiculously. Another really important thing is that I need to share an internet connection between a total of 8 PCs at this place. Right now I only have a crappy wireless router, should I get another one? Or go with switch hub? I'm not experienced in this matter. Thanks guys!

    Read the article

  • How do I automatically connect my client to an ODBC data source on another machine with dynamic IP?

    - by Kdansky
    At the customer's place, we've got a postgres DB on a server, and a few clients. We connect them through ODBC-drivers, and all machines run windows (usually XP). Now we had a few annoying issues: The client "forgets" some flags in the ODBC drivers, such as ByteA as LO. Every time anything changes, we have to reset that, and type in the password, and sometimes even the IP of the server. On x64 machines running Windows 7, configuring this is a pain as the system settings dialogue will only show 64-bit connections by default. And most importantly: If the server changes IP because the customer restarts or replaces a switch, all connections are lost. Annoyingly, this cannot be fixed with just correcting the IP, but rather, we have to check every single place (even hba_conf) because all the settings magically disappear. Our customers often are very small companies, where "server" means "that one PC in the other room", and not "Oracle mainframe in the dungeon", so we don't want to rely on them not restarting switches. Is there a better way than to rely on these really unstable settings? Are these settings somewhere in a file which I could edit manually, to make fixing it easier?

    Read the article

  • Is it possible to update Lenovo T500 hybrid graphics driver?

    - by Shiki
    Hope someone had the same problem before. My laptop comes with two video "cards". Intel MHD4500 and ATI Radeon HD3650 (mobility). I can switch between them with the "Lenovo Battery Manager" from the taskbar. All good, but Lenovo provides the driver for this. The problem with that driver is they are a bit old. (Both Intel and ATI). For example I doubt I have any gpu accel in flash, and I experience some problem with dual display setup, which the new ATI driver would solve. Basically I want to create a new driver (I read a topic where a guy said its possible... baaack then when I was searching for something else). One needs a special ATI driver creation utility or what... sorry I can't recall the name of it. Thanks in advance. (Ah yes I forgot: The OS is a Windows 7 x64 Ultimate.)

    Read the article

  • Does anyone know where I could find a 2 input USB voltage meter?

    - by John O
    What we really need is a tiny UPS, of sorts. We'll be hooking up a solar cell and a battery to a single board computer. Currently, that SBC is a custom Pic32 device, and it does it's own UPS and voltage monitoring duties. I've been tasked with trying to replicate all of its features with off the shelf products... and for the most part I've succeeded. But I don't currently have any way to switch between two sources of juice, or monitor when they're getting low. These guys have something: http://www.mini-box.com/picoUPS-100-12V-DC-micro-UPS-system-battery-backup-system I really like it, the price is well within the budget. We might even work it in though it does 12V and I'll probably be using 5V... there are enough engineers on hand to figure out something. But I'd still have no idea what the voltage was for the PV or battery. I was hoping that there was some simple little USB multimeter thing that I could use to monitor this with, but I can't seem to come up with anything. I've found all sorts of cool hardware, but nothing that will help us. Does anyone know of anything?

    Read the article

  • Routing WIFI and LAN for specific traffic

    - by jakebird451
    I have two network devices aboard my macbook pro: WIFI (en1): Used for general traffic. Connects to an ip of 192.168.19.* via DHCP LAN (en0): Used for specific traffic. Connects to an ip of 192.168.2.10 as a static IP. Does not connect to a router, only a switch for direct routing connection. I have 4 IP addresses I need to access on the LAN: 192.168.2.1 192.168.2.21 192.168.2.20 192.168.2.30 The rest of the traffic needs to go to WIFI. I have tried setting up a routing table for the specific ip addresses, but I only managed to mess up my network. I do not venture out into the world of networking too often, but this was the latest command I have been trying: sudo route add -host 192.168.2.30 -interface en0 This command killed my ability to use ping. It told me that ping could not allocate memory (is that even possible)? It also killed my wifi access. Logging out and back in fixed the issue. I really do not mind to make this solution permanent, so I am fine with a temporary routing.

    Read the article

  • mail server checklist..

    - by Jeff
    currently we ran into some issues with our mail server setup. im preparing a list of actions that we should enforce and use in order to maintain a proper email solution within our company. we have around 80 exchange users, and send mass emails out almost on a monthly bases to 20,000 + customers each time.. the checklist i currently have: 1) mcafee mxlogic 'cloud' anti-spam functionality for incoming message. 2) antivirus on each computer in company 3) antivirus on exchange and DNS servers 4) setup SPF record 5) setup DKIM 6) setup domainkey 7) setup senderID 8) submit spf to microsoft, yahoo, etc. for 'whitelist' purposes. 9) configure size limits for messages in exchange to safe numbers 10) i have 2 outside IPs for my email server, incase one gets blacklisted, switch to the backup. 11) my internet site rests on a different ip than the mail server 12) all mass emails for company sent through 3rd party company (listtrak.com) 13) setup domain alias, media, enews, and bounce for the 3rd party mass mail software. 14) verify the setup using [email protected] 15) configure group policy and our opendns.org account to prevent unwanted actions and website viewing mass emails: 1) schedule them to send different amounts at different times (1,000 at 10am, 1,000 at 4pm, 1,000 10am next day).. 2) setup user prefences, decide what they want to receive ect. ( there interests) 3) send a more steady flow of email, maybe 100 a week with top new products instead of 20,000k every other month.. if anyone has suggestions or additions/subtractions to this checklist they are greatly appreciated. thank you

    Read the article

  • Prevent rmdir -p from traversing above a certain directory

    - by thepurplepixel
    I hacked together this script to rsync some files over ssh. The --remove-source-files option of rsync seems to remove the files it transfers, which is what I want. However, I also want the directories those files are placed in to be gone as well. The current part of the find command, -exec rmdir -p {} ; tries to remove the parent directory (in this case, /srv/torrents), but fails because it doesn't have the right permissions. What I'd like to do is stop rmdir from traversing above the directory find is run in, or find another solution to get rid of all the empty folders. I've thought of using some kind of loop with find and running rmdir without the -p switch, but I thought it wouldn't work out. Essentially, is there an alternative way to remove all the empty directories under the parent directory? Thanks in advance! #!/bin/bash HOST='<hostname>' USER='<username>' DIR='<destination directory>' SOURCE='/srv/torrents/' rsync -e "ssh -l $USER" --remove-source-files -h -4 -r --stats -m --progress -i $SOURCE $HOST:$DIR find $SOURCE -mindepth 1 -type d -empty -prune -exec rmdir -p \{\} \;

    Read the article

  • after building in more ram, bios/debian does nothing [closed]

    - by derty
    My private server has 2x1gb Ram working with a 64bit Debian and an Q6600 Intel. This runs 2 virtual mashines on it each one recives 512mb RAM. Which you can immagine is a bit tight for the hole system. Now i got 2x2gb ram from a friend. I'm not sure if thery are clocking at the same speed, but i'm sure my power adaptor is not on his limit and can handle that. So there are 2 ram sockets left at the mainboard. I shuted down the system and build in the 4 gigs and looked what happen. After pressing the start button, everything gets noisy as known BUT the screen shows nothing, not even the bios stuff it usally does. Why isn't the system booting? I can immagine that it does not direkt link between booting debian and the bios not showing a thing. Or is it Grub? I mounted the system disk, and i can see it, switch folders write stuff with "vim" it does not seems like there is a problem.

    Read the article

  • Separated virtual networks with same subnet range with 2 interface

    - by Coolpet
    I'm having some problems with routing with the following: I have a server with 2 interfaces. It has 1-1 alias contains the same subnet. the 2 interface is connected to 2 switch, which are separated from each other. Infrastructure: Eth0 192.168.16.2/20 Eth0:eth0 192.168.1.222/20 Eth1 192.168.32.3/20 Eth1:eth1 192.168.1.223/20 I have a PC which has the IP address: 192.168.1.3/24 The problem is the next: If PC is on subnet 1, I can ping it. If PC is on subnet 2, I can't ping it. traceroute shows the route is across 192.168.1.222 ping -I 192.168.1.223 192.168.1.3 is not working on subnet 2. arp entries show the MAC address belonging to the correct interface (eth1 on subnet 2) How can I force the server to look on both interface same ranged subnet for specific IP? It searches only in the first subnet. The routing table has these 2 entries: 192.168.0.0/20 dev eth0 proto kernel scope link src 192.168.1.222 192.168.0.0/20 dev eth1 proto kernel scope link src 192.168.1.223

    Read the article

  • Nginx Config - I can't access WordPress admin area

    - by WebDevDude
    I am a complete noob when it comes to Nginx, but I'm trying to make the switch over for my WordPress site. Everything works, even the permalink, but I can't access my WordPress admin directory (I get a 403 error). I have my WordPress install in a subfolder, so that complicates things a bit for me. Here is my Nginx config file: server { server_name mydomain.com; access_log /srv/www/mydomain.com/logs/access.log; error_log /srv/www/mydomain.com/logs/error.log; root /srv/www/mydomain.com/public_html; location / { index index.php; # This is cool because no php is touched for static content. # include the "?$args" part so non-default permalinks doesn't break when using query string try_files $uri $uri/ /index.php?$args; } location /myWordpressDir { try_files $uri $uri/ /myWordpressDir/index.php?$args; } location ~ \.php$ { include /etc/nginx/fastcgi_params; fastcgi_pass 127.0.0.1:9000; fastcgi_index index.php; fastcgi_param SCRIPT_FILENAME /srv/www/mydomain.com/public_html$fastcgi_script_name; fastcgi_split_path_info ^(/myWordpressDir)(/.*)$; } location ~* ^.+\.(ogg|ogv|svg|svgz|eot|otf|woff|mp4|ttf|rss|atom|jpg|jpeg|gif|png|ico|zip|tgz|gz|rar|bz2|doc|xls|exe|ppt|tar|mid|midi|wav|bmp|rtf)$ { access_log off; log_not_found off; expires max; } }

    Read the article

  • Apache with multiple domains, single IP, VirtualHost is catching the wrong traffic

    - by apuschak
    I have a SOAP web service I am providing on a apache web server. There are 6 different clients (IPs) that request data and 3 of them are hitting the wrong domain. I am trying to find a way to log which domain name the requests are coming from. Details: ServerA is the primary ServerB is the backup domain1.com - the domain the web service is on domain2.com - a seperate domain that server seperate content on ServerB ServerA is standalone for now with its own IP and DNS from domain1.com. This works for everyone. ServerB is a backup for the web service, but it already hosts domain2.com. I added entries into the apache configuration file like: <VirtualHost *:443> ServerName domain2.com DocumentRoot /var/www/html/ CustomLog logs/access_log_domain2443 common ErrorLog logs/ssl_error_log_domain2443 LogLevel debug SSLEngine on ... etc SSL directives ... </VirtualHost> I have these for both 80 and 443 for domain1 and domain2 with domain1 being second. The problem is when we switch DNS for domain1 from ServerA to ServerB, 3 out of the 6 clients show up in the debug logs as hitting domain2.com instead of domain1.com and fail their web service request because domain2.com is first in the apache configuration file and catching all requests that don't match other virtualhosts, namely domain1.com. I don't know if they are hitting www.domain1.com, domain1.com (although I added entries for both) or using the external IP address or something else. Is there a way to see which URL they are hitting not just the page request or someother way to see why the first domain is catching traffic meant for the second listed domain? In the meantime, I've put domain1.com higher in the apache configuration than domain2.com. Now it catches the requests for all clients and works, however I don't know what it is catching and would like to make domain2.com the first entry again with a correct entry for domain1.com, for however they are hitting it. Thank you for your help! Andrew

    Read the article

< Previous Page | 260 261 262 263 264 265 266 267 268 269 270 271  | Next Page >