Search Results

Search found 1298 results on 52 pages for 'ssd'.

Page 27/52 | < Previous Page | 23 24 25 26 27 28 29 30 31 32 33 34  | Next Page >

  • Flex/Flash 4 datagrid displays raw xml

    - by Setori
    Problem: Flex/Flash4 client (built with FlashBuilder4) displays the xml sent from the server exactly as is - the datagrid keeps the format of the xml. I need the datagrid to parse the input and place the data in the correct rows and columns of the datagrid. flow: click on a date in the tree and it makes a server request for batch information in xml form. Using a CallResponder I then update the datagrid's dataProvider. [code] <fx:Script> <![CDATA[ import mx.controls.Alert; [Bindable]public var selectedTreeNode:XML; public function taskTreeChanged(event:Event):void { selectedTreeNode=Tree(event.target).selectedItem as XML; var searchHubId:String = selectedTreeNode.@hub; var searchDate:String = selectedTreeNode.@lbl; if((searchHubId == "") || (searchDate == "")){ return; } findShipmentBatches(searchDate,searchHubId); } protected function findShipmentBatches(searchDate:String, searchHubId:String):void{ findShipmentBatchesResult.token = actWs.findShipmentBatches(searchDate, searchHubId); } protected function updateBatchDataGridDP():void{ task_list_dg.dataProvider = findShipmentBatchesResult.lastResult; } ]]> </fx:Script> <fx:Declarations> <actws:ActWs id="actWs" fault="Alert.show(event.fault.faultString + '\n' + event.fault.faultDetail)" showBusyCursor="true"/> <s:CallResponder id="findShipmentBatchesResult" result="updateBatchDataGridDP()"/> </fx:Declarations> <mx:AdvancedDataGrid id="task_list_dg" width="100%" height="95%" paddingLeft="0" paddingTop="0" paddingBottom="0"> <mx:columns> <mx:AdvancedDataGridColumn headerText="Receiving date" dataField="rd"/> <mx:AdvancedDataGridColumn headerText="Msg type" dataField="mt"/> <mx:AdvancedDataGridColumn headerText="SSD" dataField="ssd"/> <mx:AdvancedDataGridColumn headerText="Shipping site" dataField="sss"/> <mx:AdvancedDataGridColumn headerText="File name" dataField="fn"/> <mx:AdvancedDataGridColumn headerText="Batch number" dataField="bn"/> </mx:columns> </mx:AdvancedDataGrid> //xml example from server <batches> <batch> <rd>2010-04-23 16:31:00.0</rd> <mt>SC1REVISION01</mt> <ssd>2010-02-18 00:00:00.0</ssd> <sss>100000009</sss> <fn>Revision 1-DF-Ocean-SC1SUM-Quanta-PACT-EMEA-Scheduled Ship Date 20100218.csv</fn> <bn>10041</bn> </batch> <batches> [/code] and the xml is pretty much displayed exactly as is shown in the example above in the datagrid columns... I would appreciate your assistance.

    Read the article

  • Lighttpd not cleanly restarting (address already in use)

    - by NilObject
    When doing a dist-upgrade recently, my lighttpd-1.4.19 install on Ubuntu 8.0.4 has begun failing to restart or reload properly with the /etc/init.d/lighttpd restart command. ~$ sudo /etc/init.d/lighttpd restart * Stopping web server lighttpd ...done. * Starting web server lighttpd 2009-06-13 04:06:36: (network.c.300) can't bind to port: 80 Address already in use ...fail! The same error occurs when I do a reload. The way I get around it is to kill lighttpd and then issue the start command, but it seems like I shouldn't have to do that :) I've looked at my config files, and can't spot any immediate errors. Does anyone have any ideas what can be causing this error? This seems to be the latest version as of writing this question that is available via the apt-get route. My config file is: # Debian lighttpd configuration file # ############ Options you really have to take care of #################### ## modules to load # mod_access, mod_accesslog and mod_alias are loaded by default # all other module should only be loaded if neccesary # - saves some time # - saves memory server.modules = ( "mod_access", "mod_alias", "mod_accesslog", "mod_compress", "mod_fastcgi", "mod_rewrite", "mod_redirect", ) ## a static document-root, for virtual-hosting take look at the ## server.virtual-* options server.document-root = "/var/www/" ## where to send error-messages to server.errorlog = "/var/log/lighttpd/error.log" fastcgi.server = (".php" => (( "bin-path" => "/usr/bin/php5-cgi", "socket" => "/tmp/php.socket" ))) ## files to check for if .../ is requested index-file.names = ( "index.php", "index.html", "index.htm", "default.htm", "index.lighttpd.html" ) ## Use the "Content-Type" extended attribute to obtain mime type if possible # mimetype.use-xattr = "enable" #### accesslog module accesslog.filename = "/var/log/lighttpd/access.log" ## deny access the file-extensions # # ~ is for backupfiles from vi, emacs, joe, ... # .inc is often used for code includes which should in general not be part # of the document-root url.access-deny = ( "~", ".inc" ) ## # which extensions should not be handle via static-file transfer # # .php, .pl, .fcgi are most often handled by mod_fastcgi or mod_cgi static-file.exclude-extensions = ( ".php", ".pl", ".fcgi" ) mimetype.assign = ( ".pdf" => "application/pdf", ".sig" => "application/pgp-signature", ".spl" => "application/futuresplash", ".class" => "application/octet-stream", ".ps" => "application/postscript", ".torrent" => "application/x-bittorrent", ".dvi" => "application/x-dvi", ".gz" => "application/x-gzip", ".pac" => "application/x-ns-proxy-autoconfig", ".swf" => "application/x-shockwave-flash", ".tar.gz" => "application/x-tgz", ".tgz" => "application/x-tgz", ".tar" => "application/x-tar", ".zip" => "application/zip", ".mp3" => "audio/mpeg", ".m3u" => "audio/x-mpegurl", ".wma" => "audio/x-ms-wma", ".wax" => "audio/x-ms-wax", ".ogg" => "audio/x-wav", ".wav" => "audio/x-wav", ".gif" => "image/gif", ".jpg" => "image/jpeg", ".jpeg" => "image/jpeg", ".png" => "image/png", ".xbm" => "image/x-xbitmap", ".xpm" => "image/x-xpixmap", ".xwd" => "image/x-xwindowdump", ".css" => "text/css", ".html" => "text/html", ".htm" => "text/html", ".js" => "text/javascript", ".asc" => "text/plain", ".c" => "text/plain", ".conf" => "text/plain", ".text" => "text/plain", ".txt" => "text/plain", ".dtd" => "text/xml", ".xml" => "text/xml", ".rss" => "application/rss+xml", ".mpeg" => "video/mpeg", ".mpg" => "video/mpeg", ".mov" => "video/quicktime", ".qt" => "video/quicktime", ".avi" => "video/x-msvideo", ".asf" => "video/x-ms-asf", ".asx" => "video/x-ms-asf", ".wmv" => "video/x-ms-wmv", ".bz2" => "application/x-bzip", ".tbz" => "application/x-bzip-compressed-tar", ".tar.bz2" => "application/x-bzip-compressed-tar" ) include_shell "/usr/share/lighttpd/include-conf-enabled.pl" My /etc/init.d/lighttpd script is (untouched from installation): #!/bin/sh ### BEGIN INIT INFO # Provides: lighttpd # Required-Start: networking # Required-Stop: networking # Default-Start: 2 3 4 5 # Default-Stop: 0 1 6 # Short-Description: Start the lighttpd web server. ### END INIT INFO PATH=/sbin:/bin:/usr/sbin:/usr/bin DAEMON=/usr/sbin/lighttpd NAME=lighttpd DESC="web server" PIDFILE=/var/run/$NAME.pid SCRIPTNAME=/etc/init.d/$NAME ENV="env -i LANG=C PATH=/usr/local/bin:/usr/bin:/bin" SSD="/sbin/start-stop-daemon" DAEMON_OPTS="-f /etc/lighttpd/lighttpd.conf" test -x $DAEMON || exit 0 set -e # be sure there is a /var/run/lighttpd, even with tmpfs mkdir -p /var/run/lighttpd > /dev/null 2> /dev/null chown www-data:www-data /var/run/lighttpd chmod 0750 /var/run/lighttpd . /lib/lsb/init-functions case "$1" in start) log_daemon_msg "Starting $DESC" $NAME if ! $ENV $SSD --start --quiet\ --pidfile $PIDFILE --exec $DAEMON -- $DAEMON_OPTS ; then log_end_msg 1 else log_end_msg 0 fi ;; stop) log_daemon_msg "Stopping $DESC" $NAME if $SSD --quiet --stop --oknodo --retry 30\ --pidfile $PIDFILE --exec $DAEMON; then rm -f $PIDFILE log_end_msg 0 else log_end_msg 1 fi ;; reload) log_daemon_msg "Reloading $DESC configuration" $NAME if $SSD --stop --signal 2 --oknodo --retry 30\ --quiet --pidfile $PIDFILE --exec $DAEMON; then if $ENV $SSD --start --quiet \ --pidfile $PIDFILE --exec $DAEMON -- $DAEMON_OPTS ; then log_end_msg 0 else log_end_msg 1 fi else log_end_msg 1 fi ;; restart|force-reload) $0 stop [ -r $PIDFILE ] && while pidof lighttpd |\ grep -q `cat $PIDFILE 2>/dev/null` 2>/dev/null ; do sleep 1; done $0 start ;; *) echo "Usage: $SCRIPTNAME {start|stop|restart|reload|force-reload}" >&2 exit 1 ;; esac exit 0

    Read the article

  • Cost Comparison Hard Disk Drive to Solid State Drive on Price per Gigabyte - dispelling a myth!

    - by tonyrogerson
    It is often said that Hard Disk Drive storage is significantly cheaper per GiByte than Solid State Devices – this is wholly inaccurate within the database space. People need to look at the cost of the complete solution and not just a single component part in isolation to what is really required to meet the business requirement. Buying a single Hitachi Ultrastar 600GB 3.5” SAS 15Krpm hard disk drive will cost approximately £239.60 (http://scan.co.uk, 22nd March 2012) compared to an OCZ 600GB Z-Drive R4 CM84 PCIe costing £2,316.54 (http://scan.co.uk, 22nd March 2012); I’ve not included FusionIO ioDrive because there is no public pricing available for it – something I never understand and personally when companies do this I immediately think what are they hiding, luckily in FusionIO’s case the product is proven though is expensive compared to OCZ enterprise offerings. On the face of it the single 15Krpm hard disk has a price per GB of £0.39, the SSD £3.86; this is what you will see in the press and this is what sales people will use in comparing the two technologies – do not be fooled by this bullshit people! What is the requirement? The requirement is the database will have a static size of 400GB kept static through archiving so growth and trim will balance the database size, the client requires resilience, there will be several hundred call centre staff querying the database where queries will read a small amount of data but there will be no hot spot in the data so the randomness will come across the entire 400GB of the database, estimates predict that the IOps required will be approximately 4,000IOps at peak times, because it’s a call centre system the IO latency is important and must remain below 5ms per IO. The balance between read and write is 70% read, 30% write. The requirement is now defined and we have three of the most important pieces of the puzzle – space required, estimated IOps and maximum latency per IO. Something to consider with regard SQL Server; write activity requires synchronous IO to the storage media specifically the transaction log; that means the write thread will wait until the IO is completed and hardened off until the thread can continue execution, the requirement has stated that 30% of the system activity will be write so we can expect a high amount of synchronous activity. The hardware solution needs to be defined; two possible solutions: hard disk or solid state based; the real question now is how many hard disks are required to achieve the IO throughput, the latency and resilience, ditto for the solid state. Hard Drive solution On a test on an HP DL380, P410i controller using IOMeter against a single 15Krpm 146GB SAS drive, the throughput given on a transfer size of 8KiB against a 40GiB file on a freshly formatted disk where the partition is the only partition on the disk thus the 40GiB file is on the outer edge of the drive so more sectors can be read before head movement is required: For 100% sequential IO at a queue depth of 16 with 8 worker threads 43,537 IOps at an average latency of 2.93ms (340 MiB/s), for 100% random IO at the same queue depth and worker threads 3,733 IOps at an average latency of 34.06ms (34 MiB/s). The same test was done on the same disk but the test file was 130GiB: For 100% sequential IO at a queue depth of 16 with 8 worker threads 43,537 IOps at an average latency of 2.93ms (340 MiB/s), for 100% random IO at the same queue depth and worker threads 528 IOps at an average latency of 217.49ms (4 MiB/s). From the result it is clear random performance gets worse as the disk fills up – I’m currently writing an article on short stroking which will cover this in detail. Given the work load is random in nature looking at the random performance of the single drive when only 40 GiB of the 146 GB is used gives near the IOps required but the latency is way out. Luckily I have tested 6 x 15Krpm 146GB SAS 15Krpm drives in a RAID 0 using the same test methodology, for the same test above on a 130 GiB for each drive added the performance boost is near linear, for each drive added throughput goes up by 5 MiB/sec, IOps by 700 IOps and latency reducing nearly 50% per drive added (172 ms, 94 ms, 65 ms, 47 ms, 37 ms, 30 ms). This is because the same 130GiB is spread out more as you add drives 130 / 1, 130 / 2, 130 / 3 etc. so implicit short stroking is occurring because there is less file on each drive so less head movement required. The best latency is still 30 ms but we have the IOps required now, but that’s on a 130GiB file and not the 400GiB we need. Some reality check here: a) the drive randomness is more likely to be 50/50 and not a full 100% but the above has highlighted the effect randomness has on the drive and the more a drive fills with data the worse the effect. For argument sake let us assume that for the given workload we need 8 disks to do the job, for resilience reasons we will need 16 because we need to RAID 1+0 them in order to get the throughput and the resilience, RAID 5 would degrade performance. Cost for hard drives: 16 x £239.60 = £3,833.60 For the hard drives we will need disk controllers and a separate external disk array because the likelihood is that the server itself won’t take the drives, a quick spec off DELL for a PowerVault MD1220 which gives the dual pathing with 16 disks 146GB 15Krpm 2.5” disks is priced at £7,438.00, note its probably more once we had two controller cards to sit in the server in, racking etc. Minimum cost taking the DELL quote as an example is therefore: {Cost of Hardware} / {Storage Required} £7,438.60 / 400 = £18.595 per GB £18.59 per GiB is a far cry from the £0.39 we had been told by the salesman and the myth. Yes, the storage array is composed of 16 x 146 disks in RAID 10 (therefore 8 usable) giving an effective usable storage availability of 1168GB but the actual storage requirement is only 400 and the extra disks have had to be purchased to get the  IOps up. Solid State Drive solution A single card significantly exceeds the IOps and latency required, for resilience two will be required. ( £2,316.54 * 2 ) / 400 = £11.58 per GB With the SSD solution only two PCIe sockets are required, no external disk units, no additional controllers, no redundant controllers etc. Conclusion I hope by showing you an example that the myth that hard disk drives are cheaper per GiB than Solid State has now been dispelled - £11.58 per GB for SSD compared to £18.59 for Hard Disk. I’ve not even touched on the running costs, compare the costs of running 18 hard disks, that’s a lot of heat and power compared to two PCIe cards!Just a quick note: I've left a fair amount of information out due to this being a blog! If in doubt, email me :)I'll also deal with the myth that SSD's wear out at a later date as well - that's just way over done still, yes, 5 years ago, but now - no.

    Read the article

  • My new laptop - with a really nice battery option

    - by Rob Farley
    It was about time I got a new laptop, and so I made a phone-call to Dell to discuss my options. I decided not to get an SSD from them, because I’d rather choose one myself – the sales guy tells me that changing the HD doesn’t void my warranty, so that’s good (incidentally, I’d love to hear people’s recommendations for which SSD to get for my laptop). Unfortunately this machine only has one HD slot, but I figure that I’ll put lots of stuff onto external disks anyway. The machine I got was a Dell Studio XPS 16. It’s red (which suits my company), but also has the Intel® Core™ i7-820QM Processor, which is 4 Cores/8 Threads. Makes for a pretty Task Manager, but nothing like the one I saw at SQLBits last year (at 96 cores), or the one that my good friend James Rowland-Jones writes about here. But the reason for this post is actually something in the software that comes with the machine – you know, the stuff that most people uninstall at the earliest opportunity. I had just reinstalled the operating system, and was going through the utilities to get the drivers up-to-date, when I noticed that one of Dell applications included an option to disable battery charging. So I installed it. And sure enough, I can tell the battery not to charge now. Clearly Dell see it as a temporary option, and one that’s designed for when you’re on a plane. But for me, I most often use my laptop with the power plugged in, which means I don’t need to have my battery continually topping itself up. So I really love this option, but I feel like it could go a little further. I’d like “Not Charging” to be the default option, and let me set it when I want to charge it (which should theoretically make my battery last longer). I also intend to work out how this option works, so that I can script it and put it into my StartUp options (so it can be the Default setting). Actually – if someone has already worked this out and can tell me what it does, then please feel free to let me know. Even better would be an external switch. I had a switch on my old laptop (a Dell Latitude) for WiFi, so that I could turn that off before I turned on the computer (this laptop doesn’t give me that option – no physical switch for flight mode). I guess it just means I’ll get used to leaving the WiFi off by default, and turning it on when I want it – might save myself some battery power that way too. Soon I’ll need to take the plunge and sync my iPhone with the new laptop. I’m a little worried that I might lose something – Apple’s messages about how my stuff will be wiped and replaced with what’s on the PC doesn’t fill me with confidence, as it’s a new PC that doesn’t have stuff on it. But having a new machine is definitely a nice experience, and one that I can recommend. I’m sure when I get around to buying an SSD I’ll feel like it’s shiny and new all over again! Share this post: email it! | bookmark it! | digg it! | reddit! | kick it! | live it!

    Read the article

  • 12.10 unable to install or even run from Live CD with nVidia GTX 580

    - by user99056
    I've used Ubuntu in the past (set up as web server, etc over in Iraq), so I'm not a 100% Linux Noob, however, I'm running into a brick wall here. I've got a machine I built when I got back to the US earlier this year, running Windows 7 Ultimate on it, and I've now got some free time and would like to transition over to Ubuntu full time. I've searched around in the forums, and there seems to be an issue with the nVidia graphics cards, so I've tried going to the EVGA site to see if I could find a new BIOS update for it and had no luck, so I'm back searching the forums here again and decided to just go ahead and post my question. My apologies if this is covered in another post and I was just unable to find it. I've found a few 'similar' posts, but nothing as bad as my issue. With the history aside, here is the actual detailed issue: I purchased a new SSD (Intel 520 SSD), arrived today, and I disconnect my old Windows 7 SSD. I had pre downloaded the ubuntu-12.10-desktop-amd64 earlier today and burned it to DVD. Upon inserting the Live CD into the computer and booting up, everything was fine up to the 'Run From Live CD' or 'Install Ubuntu Now' buttons. As I was sure I wanted to go ahead and make the switch, I selected the 'Install Now' from the right hand side. CD Spins up, black window pops up, and then the errors started: date/time GPU Lockup date/time Failed to idle channel 1 date/time PFIFO - playlist update failed date/time Failed to idle channel 2 date/time PFIFO - playlist update failed Thinking it might correct itself, I let it run and it would swap over to a GUI Screen that was locked up with major blurring/etc, then back to the command line with the errors. Eventually it said something along the lines of 'unknown status' and switched back to the GUI and froze. So, that's when I tried to see if I could find a BIOS upgrade for the nVidia GTX580 cards, and had no luck. So I thought, why not try to just run it from the Live CD and see if I can at least get a look at it, maybe if I could get it running try to do some sort of install from there and fix the driver issue. I rebooted, brought up the Live CD, and this time chose the left option / run from the CD. It brought me all the way in to the desktop, I saw my drives, the other icons, could move the mouse, etc for about 30 seconds and then it locked up completely. I've tried this a couple of times and get the same results every time. Hardware: Intel i7-3930K CPU @ 3.2GHz (12 CPUs) / MSI MS-7760 Motherboard / 32GB RAM / 2 x EVGA (nVidia) GeForce GTX 580 (4GB Ram each) So the question is: Is there any way to install 12.10 if you can't even get the Live CD to run (for more than 30 seconds)? My current hardware configuration is both of the GTX 580 cards have an SLI jumper on them, and I have 2 monitors on each card. (Ubuntu info obviously only shows on the main monitor from the failed installation and the attempt at running the Live CD). Perhaps opening the machine back up and removing the SLI Jumper and removing the other 3 monitors (so it only would have 1 video card with one monitor on it) would actually allow me to get 12.10 installed, then I could work on an nVidia Video Driver fix for the GTX 580, and then possibly hook up the other video card and monitors? Or is this something that they are currently aware of and may update with a future release in the next few days/weeks? Any thoughts or suggestions would be greatly appreciated, as I can't even try to fix the issue (assuming it is the nVidia drivers) if I can't even get it to install at all.

    Read the article

  • ????????????????

    - by Yusuke.Yamamoto
    ????????? ????????? ????????? ????·???? ?????:Oracle???????·??????(????)??:?????????????? Pickup!:IT???????????!|????????:100???????!|???????????? ????????:?Oracle DB?????????????????????Windows?VMware?? ?????:Oracle OpenWorld Tokyo 2012|JavaOne Tokyo 2012|??????:151 ?OTN ???? ?????? ????????:???????100???????! ?????????????????Amazon????Get! ???? Oracle Technology Network, ????/????, ??IT???????·?????????????? ???????/???MySQL?????? ?????? ???????/???MySQL????? ?????????Oracle VM VirtualBox????Oracle Real Application Clusters (RAC) 11g Release 2????? ???????/??????????????????????????????? ???????/?????????????/????·????????Flashback Database with SSD? ????? ????? Oracle?????????????????????????!???????????? Oracle Enterprise Manager 12c(EM12c):????????? ~????????~ ???????????!??????·??????? Oracle Linux 5.8?????????? ???DB?????Oracle SQL Developer 3.1???????????? Oracle??????(OUI:Oracle Universal Installer)???? ????? ???? ????????? ????????????·???????? ????????????? ???????? 11gR2 ?????????? Oracle Database 11g R2 Oracle WebLogic Server 11g R1 Oracle Enterprise Manager 11g R1 ????? ????????? Oracle Database ????????????????·?? ???????/???????????????? ?????????(????????, ???, etc) ????????(???, ?????, REDO, ???·????, etc) ????·?????????????????(?????, ???, ??, ??, ??? etc) ????·?????????(??, etc) ????????????? ???????????????????·?????? ??????? ???? ????????·??|SQL Server Windows Server ??????????PL/SQL|Java|.NET|PHP ??/??? ORACLE MASTER ???? DWH(?????????)??·?? ????? ?????(SAN, NAS, SSD, etc) Oracle Database ??????? Amazon EC2 Microsoft Excel Microsoft Visual Studio MSFC/MSCS(Microsoft Cluster Service) SAP ??·??????? Oracle Database Oracle Database 11g Release 2(11gR2) Oracle Database Standard Edition ????????: Advanced Compression ?????????: Advanced Security Application Express(APEX) Automatic Storage Management(ASM) SSD???Oracle???: Database Smart Flash Cache ??????????: Data Guard/Active Data Guard Data Pump Oracle Data Provider for .NET(ODP.NET) ????: Oracle Text Partitioning(???????/?????????) DB????: Real Application Clusters(RAC) Real Application Testing Recovery Manager(RMAN) SQL*Loader|SQL*Plus|Statspack ??????|????????|???????? Database Appliance Database Firewall Exadata Database Machine SQL Developer ?????DB: TimesTen In-Memory Database Oracle Fusion Middleware Java Oracle Coherence Oracle Data Integrator(ODI) Oracle GoldenGate Oracle JRockit JVM Oracle WebLogic Server Oracle Enterprise Manager for Database|for Middleware ????????????: Oracle Application Testing Suite Oracle Linux Oracle Solaris DTrace|ZFS|???/???? Oracle VM Server for x86 ?????? ???????? ?????????Oracle???????????????·????????????????? ?????????(??·??????) OTN??????(??????) ???????(????????) Oracle University(??) ??????! ?????... ????? ?????? ????? ?????? ?????|?Sun?? ???????? OTN???????? OTN(????) ?????? ???? OTN???|???? OTN?????? ??????? ?????? ???????? ???? ???????

    Read the article

  • What does 'Highest active time' for disk activity in Windows resource monitor mean?

    - by Nick R
    I know what the disk io, disk queue length and other measures are, but what does 'Highest active time' mean? Is it the amount of time it is busy handling requests, or something else? When it is high, does it mean the CPU is busy doing some IO work, or is it just indicating that the disk is busy handling requests? I'm trying to work out if 50% active time means that 50% of the time the disk is either seeking, reading or writing, rather than the kernel is spending 50% of it's time servicing IO requests. Edit Another quick data point here. If you look at the difference between an SSD and a physical disk, the SSD has significantly less activity, so I guess this really means the amount of time the operating system is waiting for the disk to respond and returning data.

    Read the article

  • Windows could not update the computer's boot configuration.

    - by Luke Puplett
    Hello, I am trying to install Windows Web Server 2008 x64 (have tried 32-bit, too) onto an IBM eServer 326m and am getting the following error message some time after the unpacking files section: Windows could not update the computer's boot configuration. Installation cannot proceed. I can repair the boot information using the Repair option in the WinPE bit of the setup, and it reboots into the Windows installation, so it has good boot data on the drive. Just to complicate things, the server does not have a DVD-ROM so I'm installing from HDD to HDD, both SATA, one an SSD. I've tried each drive in isolation, e.g. removing the SSD and installing from spindle onto itself, same error every time. Flashed IBM BIOS, too. Thanks for your help. Luke

    Read the article

  • Cannot boot to HDD or Optical when Motherboard in AHCI mode

    - by Shevek
    I have an Abit AB9 QuadGT motherboard and am trying to swap over to AHCI mode. I have an existing Windows 7 installation which was installed under IDE mode. I have set the msahci registry setting to 0. When I try to boot in AHCI mode I get "DISK BOOT FAILURE, INSERT SYSTEM DISK AND PRESS ENTER". I have tried booting with my Win 7 DVD in the optical drive. There is 1 SSD (System), 1 HDD (Data) and 2 optical drives connected via SATA If I switch back to IDE mode everything boots fine, either from the SSD or from a CD or DVD in the optical drive. Why can't I use AHCI mode?

    Read the article

  • Installing Win8 from ISO image error

    - by eco_bach
    I installed a new SSD in my PC laptop which came with an OEM version of Windows 8. After trying unsuccesfully to get the OEM version of Windows onto the SSD drive I gave up and purchased and downloaded a NEW copy of Windows 8. After that I created an ISO image on my desktop machine and followed the instructions here to create a bootable USB flash drive. However, after going through the boot install process with the USB flash drive on my laptop I get the following message 'The product key entered does not match any of the Windows images available for installation. Enter a different product key.' But I wasn't asked to enter any key! Is this because the ISO image was created on a different machine? I really don't get why this should be so difficult.

    Read the article

  • Can't start the Windows Phone Emulator

    - by Louis
    When I try run/debug an app in the emulator I get this error: And in Visual Studio's Error List console it simply says: 0x80131500 I haven't worked on this project for about a week, but it was working then. I checked the BIOS and everything is enabled (as it was last week). I don't think this is related, but yesterday, I did upgrade my system SSD and used the Samsung Data Migration Tool to clone my drive. I've tried repairing the Windows Phone SDK 8.0, but that didn't help. Are there any other things I can try? I really don't think it's related to the SSD. Hyper-V related services: I can't start any of these either.

    Read the article

  • How can I use a batch shortcut to open multiple Windows Explorer folders, and a Notepad file?

    - by ModelHX
    I've recently built a computer with an SSD in it (my first) and am in the process of moving a select few of my Steam games to the SSD and symbolically linking them to where they're supposed to be on the main (mechanical) hard drive so that Steam doesn't throw a fit and I get maximum performance. To this end, I'm finding myself repeatedly navigating to both target folders to move the relevant files and opening a specific Notepad file to enter the relevant paths into a template I've got set up that I paste into the Windows command prompt to create the symlink. This is annoying. I've read up a little bit on batch shortcuts, and have a basic understanding on how to use one to open programs and files. However, I'm finding a lot of confusing suggestions on how to use batch shortcuts to open specific folders in Windows Explorer, and none of them deal with opening multiple folders at once. Any assistance on writing the shortcut would be greatly appreciated. Thank you for your time.

    Read the article

  • Missing disc when installing windows 7

    - by Anders
    Hi, when I was installing windows 7 on my new bought computer it asked me on which disc I would like to install the OS on, either the 1 tera byte disc or the ssd disc, I chose to install it on the ssd disc. But now when I have installed the OS, the 1 tera byte disc isn't visible in "my computer" and I don't know how to access it, I didn't do anything strange in the installation, that by the way is idiot secure. So my question, what do you think have happend and how do you believe that this issue is solved? Regards Anders

    Read the article

  • Permanently mount multiple directories from different disks under /

    - by piotrek
    I have SSD and HDD. Some directories like /var, /srv and /tmp should be on HDD, while /boot, /usr and /lib on SSD. But do I have to create separate partition for every single directory? I want to have 2 or so partitions. One for each disk and distribute directories as needed. Is it possible and how? I've heard about symlinks, mount --bind, mhddfs but: symlinks are treated differently by tools like cp, so I'm not sure if it's safe to have main system directories symlinked I have no idea how can I use mount --bind or mhddfs in fstab

    Read the article

  • How to move a windows machine properly from RAID 1 to raid 10?

    - by goober
    Goal I would like to add two more hard drives to my current RAID 1 setup and create a RAID 0 setup on top of the two RAID 1 setups (which I believe is referred to as "RAID 10"). Components Involved Intel P68 Chipset Motherboard 4 SATA ports that can be configured for Raid An intel SSD cache that sits in front of the RAID, and a 64 GB SSD configured in that manner Two 1TB HDDs configured in RAID 1 OS: Windows 7 Professional Resources Consulted so far I found a great resource on LinuxQuestions.org for a good "best practices" process for Linux machines, but I'd like to develop a similar process that I know works on Windows Machines.

    Read the article

  • Mount drive when symbolic link is accessed

    - by Danilo Campos
    I have a MacBook Pro with two internal drives: an SSD and a slow rotational drive. On the rotational drive I keep heavy, rarely accessed files like movies, photos, etc. These are symlinked from the SSD, so applications like iPhoto and iTunes will still find everything where they expect. I don't usually have the rotational drive mounted because it's loud and mostly unused. Is there a way to mount it when the system tries to access data behind a symlink, then unmount it automatically later? (Intermediate *nix user, here, feel free to tell me I am asking for magic.) Thanks for your help!

    Read the article

  • How could I let Skydrive desktop sync to MicroSD in Windows 8 tablet?

    - by peSHIr
    I have a Samsung Slate 7 tablet with (now) Windows 8 on it. This machine has a 64 Gb SSD and I have a 64 Gb MicroSD card in it. I also have a Skydrive on my main Microsoft ID that contains about 45 Gb of content. With Windows and some development stuff installed, my Skydrive will not fit on the main drive of the tablet. (Besides, my idea was to keep data on the memory card anyway, to make it easier to repave the machine without data loss if need be.) My problem should now be clear: I want to install the Skydrive desktop app to sync my Skydrive to the MicroSD card. This is not possible, as Skydrive does not allow syncing files to removable drives. I have tried a number of things already, but none of them worked: Use the mklink command line tool to create a directory link/junction from a folder name on SSD to a folder on the MicroSD and then try to install Skydrive sync to the SSD link folder. Skydrive however still recognizes this as something it does not want to sync onto. The various different filter drivers mentioned on Agnipulse (including the Hitachi one) that should make windows see some or all of the removable drives in the system as fixed drives do not seem work on (64-bit) Windows 8: they either can't be installed, do nothing and/or cause Windows 8 to go into Automatic Repair mode when rebooting. The Lexar BootIt app seems to be meant to flip the relevant bit in the on-board drive controller of supported USB pen drives, but I tried it anyway. Of course it did nothing to how the MicroSD card was seen. I have now run out of ideas, it seems, and I was wondering if anyone here has a solution to let Windows 8 see the MicroSD memory card in my tablet as a fixed drive instead of removable drive, or some other way of getting the Skydrive desktop to sync my Skydrive data to that MicroSD card. And to be complete: this is not a duplicate question of this or this as those ask about getting USB drives multiple partitions to work on Windows XP. This question is specific about getting desktop Skydrive to sync to MicroSD card in Windows 8, which seems to be a question I have not seen on superuser so far.

    Read the article

  • Recommended Setup

    - by Chris Ryan
    I have been running into issue with my MSSQL Database setup with speed. Here is my scenario. About 100M Rows Average: 1k Updates Per Second Hard Drives: RAID 10 SSD MDF --Active Time: 0 Log Drives: 1 SSD LDF - Simple Recovery --Active Time 99.9 --Queue: 8 I do not need a back up of the log so it is set to simple recovery but my bottleneck is still at my log. I get high WAITLOG times and thus it can not update any faster. I can't do bulk updates/transactions and each update needs to be one at a time. Is my only option to increase write performance of the log drives, add a RAID drives? Any suggestions on increasing the performance?

    Read the article

  • Best motherboard power supply combo for backblaze server

    - by jin14
    Building a backblaze server as described in this article. http://blog.backblaze.com/ So 45 hard drives in one box. I'm making it a MSDPM 2010 server so I actually don't even need raid cards in there as MSDPM will figure out how to use all of the hard drives on it's own. So need to know what motherboard, CPU, power supply I should get. Primary hard drive : SSD 128GB Storage : 45 1.5GB sata drives OS : windows 2008 Backup software : Microsoft System center Data protection server 2010 Need to know Which mother board to buy which will support 45 SATA hard drives. Don't need a raid card. Which power supply can power all 45 hard drives, 1 ssd drive, motherboard. Best set of equipment that meets my needs wins

    Read the article

  • Choosing A Power Supply [closed]

    - by Geeks On Hugs
    Possible Duplicate: Power Supply Capacity Formula How can I check if my system needs more PSU power? I'm not sure if it's OK or not to ask a hardware question here. If not please let me know a good place but I've always got good info here so I thought I'd give it a shot. I'm custom building a new workstation for coding (Linux/Eclipse). How do I determine how much power the power supply needs? I'm building a mini ITX system on a budget and so I need to get as small as possible that is sufficient. I'll have a mini itx mobo with on board wifi and bluetooth, 8 GB RAM, an Intel i3 3.1 Ghz processor, 64 GB SSD and a slim optical drive. In the future I might add a descrete GPU, 16 GB RAM, 128 GB SSD. What is the minimum power I need and how do I calculate that?

    Read the article

  • What are performance limits of a database?

    - by Tommy
    What are some rough performance limits (read/s, write/s) for a single database server (no master-slave architecture), assuming storage on disk? How many read/s, write/s, depending on the kind of disk? (SSD vs non-SSD) , assuming simple operations (select one row by primary key, update one row, correctly indexed). I assume this limit is dependent on disk seek/write. EDIT: My question is more about getting rough metrics of the number of operations a database supports: to be able to know for example, if a new feature triggering 300 inserts/s can be supported without scaling out with additional servers.

    Read the article

  • High disk time on sql-server

    - by Patrik
    Hi We have a dedicated sql-server 2008 r2 enterprise edition. The setup is: D: (data files) - stored on local ssd disks (not the same disks as log files) (raid 10) E: (log files) - stored on local ssd disks (not the same disks as data files) (raid 1) F: (transaction log backup) - stored remote on a SAN Today we moved our log files to new disks (from F: to E:). From a shared volume ( F:(SAN)) to dedicated local disks (E:). What then happend was that the "disk time", "avg. transfer time" and "avg disk write queue length" increased on the volume where we have the data files (D:) (not on the volume where the log files are located). The data volume and log volume does not share disks, however they share the same controller card. "Disk idle time" is low for all volumes. One thought is ofcourse that the controller card might be overloaded. But, we need more ideas on where the problem might be.

    Read the article

  • Missing disk space in Windows XP

    - by Jørn Schou-Rode
    On my mother's Lenovo laptop, Windows XP claims that the hard drive is almost full. According to the properties window, 52.7 out of 55.2 GB is in use: By deleting temp files from Internet Explorer, System Restore, Recycle bin, Windows Update, System Cleanup, I managed to free up about one GB. That's still 50 GB in use, which still is a lot more than I expected. Hence, I gave good old WinDirStat a spin, and here's the output: It might be hard to read here, but the first line says that the total amount of disk space in use on drive C is 24.3 GB. So Windows claims usage of 52.7 GB and WinDirStat can only account for 24.3 GB. Where is the other half of that disk space being used? I hope someone has an answer, or some tricks or tips to do further research. UPDATE: The laptop in question has an SSD hard drive. I am aware that these disk (at least the earlier ones) have a limited life-time. Could the symptoms described be caused by wear and tear on the SSD?

    Read the article

  • Is it really necessary to call /bin/sync twice before an unmanaged power-off?

    - by Jeremy Friesner
    Hi all, My company sells an "embedded device" which is implemented as a headless Linux box with ext4 on an internal SSD. Some of our users have a habit of doing a "save current settings" on this box, and then cutting power to the unit as soon as the unit reports that the save completed (ie two seconds later). This was causing occasional corruption of the saved files, as the data wouldn't always get flushed to the SSD before the power went out. So I tweaked my software to run /bin/sync immediately after writing the file (after closing the file handle but before notifying the user that the save completed). This appears to fix the issue, but my coworker says that one call to /bin/sync isn't sufficient, and that to be really safe I ought to run /bin/sync twice in a row. That sounds like paranoia to me... Perhaps a habit from earlier versions of Linux or unix whose sync utility didn't work reliably. Does his advice have merit, or should one call to /bin/sync suffice?

    Read the article

  • Is it safe to use consumer MLC SSDs in a server?

    - by Zypher
    We (and by we I mean Jeff) are looking into the possibility of using Consumer MLC SSD disks in our backup data center. We want to try to keep costs down and usable space up - so the Intel X25-E's are pretty much out at about 700$ each and 64GB of capacity. What we are thinking of doing is to buy some of the lower end SSD's that offer more capacity at a lower price point. My boss doesn't think spending about 5k for disks in servers running out of the backup data center is worth the investment. Just how dangerous of an approach is this and what can be done to mitigate these dangers?

    Read the article

< Previous Page | 23 24 25 26 27 28 29 30 31 32 33 34  | Next Page >