Search Results

Search found 4620 results on 185 pages for 'serial over lan'.

Page 28/185 | < Previous Page | 24 25 26 27 28 29 30 31 32 33 34 35  | Next Page >

  • VPN into multiple LAN Subnets

    - by Rain
    I need to figure out a way to allow access to two LAN subnets on a SonicWall NSA 220 through the built-in SonicWall GlobalVPN server. I've Googled and tried everything I can think of, but nothing has worked. The SonicWall NSA management web interface is also very unorganized; I'm probably missing something simple/obvious. There are two networks, called Network A and Network B for simplicity, with two different subnets. A SonicWall NSA 220 is the router/firewall/DHCP Server for Network A, which is plugged into the X2 port. Some other router is the router/firewall/DHCP server for Network B. Both of these networks need to be managed through a VPN connection. I setup the X3 interface on the SonicWall to have a static IP in the Network B subnet and plugged it in. Network A and Network B should not be able to access each other, which appears the be the default configuration. I then configured and enabled VPN. The SonicWall currently has the X1 interface setup with a subnet of 192.168.1.0/24 with a DHCP Server enabled, although it is not plugged in. When I VPN into the SonicWall, I get an IP address supplied by the DHCP Server on the X1 interface and I can access Network A remotely although I do not have access to Network B. How can I allow access to both Network A and Network B to VPN clients although keep devices on Network B from accessing Network A and vice-versa. Is there some way to create a VPN-only subnet (something like 10.100.0.0/24) on the SonicWall that can access Network A and Network B without changing the current network configuration or allowing devices on both netorks "see" each other? How would I go about setting this up? Diagram of the network: (Hopefully this kind of helps) WAN1 WAN2 | | [ SonicWall NSA 220 ]-(X3)-----------------[ Router 2 ] | | (X2) 192.168.2.0/24 10.1.1.0/24 Any help would be greatly appriciated!

    Read the article

  • LAN Webserver not accessible through PPTP VPN

    - by Joe
    I have this LAN Network with 10 clients and one server. The server has 4 virtual machines and a BIND DNS Server. When the router assigns an IP through the DHCP , it also gives the ip of the DNS Server, to resolve internal domains. Everything apparently works fine, the clients being able to access the server's vm's resources, but I also have to create the possibility of remote access. I installed the PPTP VPN on the server, and the vpn clients would get the same ip address range as the router's dhcp is assigning. Apparently everything is fine here also, except the fact that when we connect through the vpn , we cannot access the webserver on port 80 ( the webserver being one of the server's VM ). The iptables on the webserver has been turned off for testing purposes and the router's firewall is directing all the external traffic to the server. Can somebody suggest a solution to this? Extra details : VPN Server : PPTP Server Centos 6.3 x64 VPN Client : Windows 7 default PPTP VPN Connection The client is successfully connected to the server, everything works ( FTP/MYSQL/SSH/DNS ) , except the fact that when I try to access the webserver IP on the browser, it won't work.Pinging it works perfectly.

    Read the article

  • Problem receving in RXTX

    - by drhorrible
    I've been using RXTX for about a year now, without too many problems. I just started a new program to interact with a new piece of hardware, so I reused the connect() method I've used on my other projects, but I have a weird problem I've never seen before. The Problem The device works fine, because when I connect with hyperterminal, I send things and receive what I expect, and Serial Port Monitor(SPM) reflects this. However, when I run the simple hyperterminal-clone I wrote to diagnose the problem I'm having with my main app, bytes are sent, according to SPM, but nothing is received, and my SerialPortEventListener never fires. Even when I check for available data in the main loop, reader.ready() returns false. If I ignore this check, then I get an exception, details below. Relevant section of connect() method // Configure and open port port = (SerialPort) CommPortIdentifier.getPortIdentifier(name) .open(owner,1000) port.setSerialPortParams(baud, databits, stopbits, parity); port.setFlowControlMode(fc_mode); final BufferedReader br = new BufferedReader( new InputStreamReader( port.getInputStream(), "US-ASCII")); // Add listener to print received characters to screen port.addEventListener(new SerialPortEventListener(){ public void serialEvent(SerialPortEvent ev) { try { System.out.println("Received: "+br.readLine()); } catch (IOException e) { e.printStackTrace(); } } }); port.notifyOnDataAvailable(); Exception java.io.IOException: Underlying input stream returned zero bytes at sun.nio.cs.StreamDecoder.readBytes(StreamDecoder.java:268) at sun.nio.cs.StreamDecoder.implRead(StreamDecoder.java:306) at sun.nio.cs.StreamDecoder.read(StreamDecoder.java:158) at java.io.InputStreamReader.read(InputStreamReader.java:167) at java.io.BufferedReader.fill(BufferedReader.java:136) at java.io.BufferedReader.read(BufferedReader.java:157) at <my code> The big question (again) I think I've eliminated all possible hardware problems, so what could be wrong with my code, or the RXTX library? Edit: something interesting When I open hyperterminal after sending a bunch of commands from java that should have gotten responses, all of the responses appear immediately, as if they had been put in the buffer somewhere, but unavailable. Edit 2: Tried something new, same results I ran the code example found here, with the same results. No data came in, but when I switched to a new program, it came all at once. Edit 3 The hardware is fine, and even a different computer has the same problem. I am not using any sort of USB adapter. I've started using PortMon, too, and it's giving me some interesting results. Hyperterminal and RXTX are not using the same settings, and RXTX always polls the port, unlike HyperTerminal, but I still can't see what settings would affect this. As soon as I can isolate the configuration from the constant polling, I'll post my PortMon logs. Edit 4 Is it possible that some sort of Windows update in the last 3 months could have caused this? It has screwed up one of my MATLAB mex-based programs once. Edit 5 I've also noticed some things that are different between HyperTerminal, RXTX, and a separate program I found that communicates with the device (but doesn't do what I want, which is why I'm rolling my own program) HyperTerminal - set to no flow control, but Serial Port Monitor's RTS and DTR indicators are green Other program - not sure what settings it thinks it's using, but only SPM's RTS indicator is green RXTX - no matter what flow control I set, only SPM's CTS and DTR indicators are on. From Serial Port Monitor's help files (paraphrased): the indicators display the state of the serial control lines RTS - Request To Send CTS - Clear To Send DTR - Data Terminal Ready

    Read the article

  • Binary data from a serial port in linux using c

    - by user1680393
    I am reading binary data from a serial port on Phidget sbc using Linux to get a command from an application running on a PC. I wrote a test program in VB to read the data into a byte array and convert it to decimal to use it but can’t figure out how to do it in c. I am unable to come up with anything with the research I have done on the internet. Command sent from PC is 0x0F. To check if I am getting correct data I read the data and send it back. Here is what I get back. Returned data has a carriage return added to it. Hex Display 0F00 0000 0D ‘\’ Display \0F\00\00\00\r Normal display just display a strange character. This tells me that the data is there that I can use, but can’t figure out to extract the value 0F or 15. How can I convert the incoming data to use it? I tried converting the received data using strtol, but it returns 0. I also tried setting the port to raw but it did not make any difference. unsigned char buffer1[1]; int ReadPort1() { int result; result = read(file1, &buffer1,1); if(result > 0) { WritePort1(buffer1); sprintf(tempstr, "Port1 data %s %d", buffer1, result); DisplayText(2,tempstr); } return result; } Port Open/Setup void OpenPort1() { //file1 = open("/dev/ttyUSB1", O_RDWR | O_NOCTTY | O_NONBLOCK); file1 = open("/dev/ttyUSB1", O_RDWR | O_NOCTTY | O_NODELAY); if(file1 < 0) printf("Error opening serial port1.\n"); else { SetPort(file1, 115200, 8, 1, 0, 1); port1open = 1; } } void SetPort(int fd, int Baud_Rate, int Data_Bits, int Stop_Bits, int Parity, int raw) { long BAUD; // derived baud rate from command line long DATABITS; long STOPBITS; long PARITYON; long PARITY; struct termios newtio; switch (Baud_Rate) { case 115200: BAUD = B115200; break; case 38400: BAUD = B38400; break; case 19200: BAUD = B19200; break; case 9600: BAUD = B9600; break; } //end of switch baud_rate switch (Data_Bits) { case 8: default: DATABITS = CS8; break; case 7: DATABITS = CS7; break; case 6: DATABITS = CS6; break; case 5: DATABITS = CS5; break; } //end of switch data_bits switch (Stop_Bits) { case 1: default: STOPBITS = 0; break; case 2: STOPBITS = CSTOPB; break; } //end of switch stop bits switch (Parity) { case 0: default: //none PARITYON = 0; PARITY = 0; break; case 1: //odd PARITYON = PARENB; PARITY = PARODD; break; case 2: //even PARITYON = PARENB; PARITY = 0; break; } //end of switch parity newtio.c_cflag = BAUD | DATABITS | STOPBITS | PARITYON | PARITY | CLOCAL | CREAD; newtio.c_iflag = IGNPAR; if(raw == 1) { newtio.c_oflag &= ~OPOST; newtio.c_lflag &= ~(ICANON | ECHO | ECHOE | ISIG); } else { newtio.c_lflag = 0; //ICANON; newtio.c_oflag = 0; } newtio.c_cc[VMIN]=1; newtio.c_cc[VTIME]=0; tcflush(fd, TCIFLUSH); tcsetattr(fd,TCSANOW,&newtio); }

    Read the article

  • getUserPrincipal() in JCIFS / Lan-Manager authentitation level setting in Windows 2k8

    - by Chris
    I have to find out in which exact format JCIFS stores the user principal in the "getUserPrincipal()" property. Therefor i created a test Environment like this: Windows Server 2008 Domain Controller Domain named "MYDOMAIN" Many Testusers in Active Directory Tomcat Application Server with my Web Application (which simply reads the user Principal and displays its values). The user should be logged in to the web-application with SSO therefor i need the format that jcifs is using to store the user. (For example user@MYDOMAIN or MYDOMAIN\user...) I tested the Authentication with other SSO frameworks with Kerberos Method and it works as expected. I'm now trying to use SSO through the NTLMHttpFilter of JCIFS. When i try to login i get the following error message: jcifs.smb.SmbException: The parameter is incorrect. jcifs.smb.SmbTransport.checkStatus(SmbTransport.java:541) jcifs.smb.SmbTransport.send(SmbTransport.java:641) jcifs.smb.SmbSession.sessionSetup(SmbSession.java:322) jcifs.smb.SmbSession.send(SmbSession.java:224) jcifs.smb.SmbTree.treeConnect(SmbTree.java:176) jcifs.smb.SmbSession.logon(SmbSession.java:153) jcifs.smb.SmbSession.logon(SmbSession.java:146) jcifs.http.NtlmHttpFilter.negotiate(NtlmHttpFilter.java:189) jcifs.http.NtlmHttpFilter.doFilter(NtlmHttpFilter.java:121) Regarding to the documentation i'm using to configure this, this is a know issue with the Group policy. It is stated there, that i have to change the Group policy "Networkaccess: lan-manager authentication level" to respond to NTLMv1 request. I have done this, but it's still not working. So what i also have to configure is the same policy on the client computer. I have to change the policy, so that the client computer sends NTLMv1. But it is always sending NTLMv2 tokens. The problem now is that i'm somehow not able to change this setting. (I already was before) because the dropdown box to choose the authentication method is "greyed out". edit: just to make this clear, this dialog is on the client-side in the "local-security policies" As you can see from this screenshot, the chosen method is "Only send NTLMv2 responses" which is the wrong setting and i'm pretty sure that this is causing the error above. My question is now, why can't i change this setting? Why is it greyd out?

    Read the article

  • How can I use my cell phone to establish a dial-up networking connection?

    - by gWiz
    I am using Windows 7 and have a BlackBerry with T-Mobile (U.S.). I have paired the phone with my computer over Bluetooth, which automatically creates a serial port for it. I am able to open the port in PuTTY and successfully issue AT commands to the modem, including dialing. However, while using Windows to create and establish a Dial-Up Networking connection, I get an error dialog stating "Error 678. The remote computer did not respond." In my testing, I also tried setting up a connection to dial a number connected to a phone. When attempting to connect over this connection, the phone does ring but the very moment I answer the call, my computer displays the above error dialog. What must be done to successfully establish such a PPP connection? Some special AT initialization string perhaps? To clarify, I'm not referring to the well-described and popular technique known as "tethering," in which the remote host of the data link is the mobile service provider. I am interested specifically in establishing direct data links with remote hosts other than my mobile service provider. Think old-school landline connection to your friend's computer or BBS. Edit 1 As grawity pointed out in comments, the missing piece of the puzzle is the actual modulator that is compatible with v-series protocols, which I expected to be built into the cellphone. So far the best only software alternative I could find is this experimental project. Edit 2 Found this forum discussion today. The participants state that there is no old-school modem in the BlackBerry. Edit 3 When I place a call in PuTTY with ATD, immediately after the call is answered (and the callee is initiating the handshake) the cellphone returns OK. This is not the expected behavior for establishing a data connection. The phone should reciprocate the handshake, and upon success return CONNECT. (Alternatively it should return BUSY or NO CARRIER, but never simply OK.) Windows DUN must be interpreting this as the "Error 678" I was seeing.

    Read the article

  • Getting Serial Port Information and Sorting the Results in C#

    - by Jim Fell
    I have some code that loads the serial ports into a combo-box: comboBoxComPort.Items.Add("Select COM port..."); foreach (string s in SerialPort.GetPortNames()) { comboBoxComPort.Items.Add(s); } comboBoxComPort.SelectedIndex = 0; Ideally, I would like to add the port descriptions to the list and sort the items in the list that are after index 0. Does anyone have any suggestions for doing this? Any thoughts you may have would be appreciated. Thanks.

    Read the article

  • USB Serial cable with CDC support

    - by Harsha
    Hi All, I bought a USB to Serial cable which claims to be CDC compliant. But the bInterfaceClass value in interface descriptor is 0xFF(which is vendor specific). I was expecting it to be 0x02 (Communications and CDC control). In the device manager, i found that the drivers being loaded are ser2pl.sys and serenum.sys. I had learnt usbser.sys is the windows CDC driver, but it was not loaded for my cable. I am pretty much new to this CDC, so i have following questions 1.Does this indicate that the cable is not CDC compliant 2.Can i make this cable CDC compliant (since CDC is a driver functionality), by loading usbser.sys. If yes how?

    Read the article

  • Getting Serial Port Information in C#

    - by Jim Fell
    I have some code that loads the serial ports into a combo-box: List<String> tList = new List<String>(); comboBoxComPort.Items.Clear(); foreach (string s in SerialPort.GetPortNames()) { tList.Add(s); } tList.Sort(); comboBoxComPort.Items.Add("Select COM port..."); comboBoxComPort.Items.AddRange(tList.ToArray()); comboBoxComPort.SelectedIndex = 0; I would like to add the port descriptions (similar to what are shown for the COM ports in the Device Manager) to the list and sort the items in the list that are after index 0 (solved: see above snippet). Does anyone have any suggestions for adding the port descriptions? I am using Microsoft Visual C# 2008 Express Edition (.NET 2.0). Any thoughts you may have would be appreciated. Thanks.

    Read the article

  • Intelligent serial port mocks with Moq

    - by Padu Merloti
    I have to write a lot of code that deals with serial ports. Usually there will be a device connected at the other end of the wire and I usually create my own mocks to simulate their behavior. I'm starting to look at Moq to help with my unit tests. It's pretty simple to use it when you need just a stub, but I want to know if it is possible and if yes how do I create a mock for a hardware device that responds differently according to what I want to test. A simple example: One of the devices I interface with receives a command (move to position x), gives back an ACK message and goes to a "moving" state until it reaches the ordered position. I want to create a test where I send the move command and then keep querying state until it reaches the final position. I want to create two versions of the mock for two different tests, one where I expect the device to reach the final position successfully and the other where it will fail. Too much to ask?

    Read the article

  • DataType for storing a long serial number (10 bytes)

    - by CrimsonX
    We have a device which has a 10 byte serial number which must be read into our application and stored into a .net datatype. In the device it is stored as an unsigned 10-byte (80-bit) number. I don't expect we will be performing any mathematical operations on this number, but only displaying it to the user. The .NET framework doesn't have a built in UNIT128 to store this datatype. My suggestion for storing this datatype is to create a 10 element byte array and read in the data into this array. Are there any better solutions to this problem? Note: I have seen in this question that a GUID is a 128 byte signed integer, but it seems like a bad idea to use a GUID in this fashion. Any other suggestions?

    Read the article

  • Unique serial number in a java web application.

    - by Zenzen
    I've been wondering what's the correct practice for generating unique ids? The thing is in my web app I'll have a plugin system, when a user registers a plugin I want to generate a unique serial ID for it. I've been thinking about storing all numbers in a DB or a file on the server, generating a random number and checking whether it already exists in the DB/file, but that doesn't seem that good. Are there other ways to do it? Would using the UUID be the preferred way to go?

    Read the article

  • Java: serial thread confinement question

    - by denis
    Assume you have a Collection(ConcurrentLinkedQueue) of Runnables with mutable state. Thread A iterates over the Collection and hands the Runnables to an ExecutorService. The run() method changes the Runnables state. The Runnable has no internal synchronization. The above is a repetitive action and the worker threads need to see the changes made by previous iterations. So a Runnable gets processed by one worker thread after another, but is never accessed by more than one thread at a time - a case of serial thread confinement(i hope ;)). The question: Will it work just with the internal synchronization of the ConcurrentLinkedQueue/ExecutorSerivce? To be more precise: If Thread A hands Runnable R to worker thread B and B changes the state of R, and then A hands R to worker thread C..does C see the modifications done by B?

    Read the article

  • Parallelizing a serial algorithm

    - by user643813
    Hej folks, I am working on porting a Text mining/Natural language application from single-core to a Map-Reduce style system. One of the steps involves a while loop similar to this: Queue<Element>; while (!queue.empty()) { Element e = queue.next(); Set<Element> result = calculateResultSet(e); if (!result.empty()) { queue.addAll(result); } } Each iteration depends on the result of the one before (kind of). There is no way of determining the number of iterations this loop will have to perform. Is there a way of parallelizing a serial algorithm such as this one? I am trying to think of a feedback mechanism, that is able to provide its own input, but how would one go about parallelizing it? Thanks for any help/remarks

    Read the article

  • Webservice for serial port devices

    - by camx
    Hi I want to create a remote webservice for an application that is now avaliable only localy. This application controlls three devices (each is controlled separately) connected on serial port. The problem is that I don't know how to take care of passing back information that a device return requested data. For example - I send move command to the motion device (which is very slow and can take a minute or more). Can I just set a big timeout on the client side (and server side) and return for example a true/false if operation is completed or is this a bad idea? Is SOAP with big timeouts ok? And the other question is if Mono on Linux (Ubuntu 9.10, Mono 2.4) is stable enought for making a web service or should I chose Java or some other language? I'm open for recommendations. Thanks for your help!

    Read the article

  • Javascript code for serial img loading

    - by Surfer
    Hi everyone, I am new to javascript. I want a javascript code with which i can load an image which is named for every day/month/year. in a serial i have the following code : var year = new Array(); year = ["08", "09", "10", "11"]; var month = new Array(); month = ["JAN", "FEB", "MAR", "APR", "MAY", "JUN", "JULY", "AUG", "SEP", "OCT", "NOV", "DEC"]; var date = new Array(); date = ["01", "02", "03", "04", "05", "06", "07", "08", "09", "10", "11", "12", "13", "14", "15", "16", "17", "18", "19", "20", "21", "22", "23", "24", "25", "26", "27", "28", "29", "30", "31"]; var ims = ""; for (var x in year) { for (var y in month) { for (var z in date) { ims += "<im src=screencover/img/" + date[z] + "" + month[y] + "20" + year[0] + ".png>"; } } } document.write(ims);

    Read the article

  • Micro Controller Serial Data identification or classification

    - by Posiedon
    I have a x51 family micro controller (P89V51RD2). I'm going to send some data from computer using serial port. The data i'll be sending are Character 'S' Character 'R' and a 2 digit integer. Upon receiving the data, I will be calling separate functions. I used if(chr=='S') and elseif(chr=='R')for character data. The main problem lies with identifying the 2 digit number sent. Any other data other than the above three mentioned will be discarded. Any ideas for identifying two digit integer ??

    Read the article

  • Mac OS X 10.8 VPN Server: Bypass VPN for LAN traffic (routing LAN traffic to secondary connection)

    - by Dan Robson
    I have somewhat of an odd setup for a VPN server with OS X Mountain Lion. It's essentially being used as a bridge to bypass my company's firewall to our extranet connection - certain things our team needs to do require unfettered access to the outside, and changing IT policies to allow traffic through the main firewall is just not an option. The extranet connection is provided through a Wireless-N router (let's call it Wi-Fi X). My Mac Mini server is configured with the connection to this router as the primary connection, thus unfettered access to the internet via the router. Connections to this device on the immediate subnet are possible through the LAN port, but outside the subnet things are less reliable. I was able to configure the VPN server to provide IP addresses to clients in the 192.168.11.150-192.168.11.200 range using both PPTP and L2TP, and I'm able to connect to the extranet through the VPN using the standard Mac OS X VPN client in System Preferences, however unsurprisingly, a local address (let's call it internal.company.com) returns nothing. I tried to bypass the limitation of the VPN Server by setting up Routes in the VPN settings. Our company uses 13.x.x.x for all internal traffic, instead of 10.x.x.x, so the routing table looked something like this: IP Address ---------- Subnet Mask ---------- Configuration 0.0.0.0 248.0.0.0 Private 8.0.0.0 252.0.0.0 Private 12.0.0.0 255.0.0.0 Private 13.0.0.0 255.0.0.0 Public 14.0.0.0 254.0.0.0 Private 16.0.0.0 240.0.0.0 Private 32.0.0.0 224.0.0.0 Private 64.0.0.0 192.0.0.0 Private 128.0.0.0 128.0.0.0 Private I was under the impression that if nothing was entered here, all traffic was routed through the VPN. With something entered, only traffic specifically marked to go through the VPN would go through the VPN, and all other traffic would be up to the client to access using its own default connection. This is why I had to specifically mark every subnet except 13.x.x.x as Private. My suspicion is that since I can't reach the VPN server from outside the local subnet, it's not making a connection to the main DNS server and thus can't be reached on the larger network. I'm thinking that entering hostnames like internal.company.com aren't kicked back to the client to resolve, because the server has no idea that the IP address falls in the public range, since I suspect (probably should ping test it but don't have access to it right now) that it can't reach the DNS server to find out anything about that hostname. It seems to me that all my options for resolving this all boil down to the same type of solution: Figure out how to reach the DNS with the secondary connection on the server. I'm thinking that if I'm able to do [something] to get my server to recognize that it should also check my local gateway (let's say Server IP == 13.100.100.50 and Gateway IP == 13.100.100.1). From there Gateway IP can tell me to go find DNS Server at 13.1.1.1 and give me information about my internal network. I'm very confused about this path -- really not sure if I'm even making sense. I thought about trying to do this client side, but that doesn't make sense either, since that would add time to each and every client side setup. Plus, it just seems more logical to solve it on the server - I could either get rid of my routing table altogether or keep it - I think the only difference would be that internal traffic would also go through the server - probably an unnecessary burden on it. Any help out there? Or am I in over my head? Forward proxy or transparent proxy is also an option for me, although I have no idea how to set either of those up. (I know, Google is my friend.)

    Read the article

  • iPhone Development with Bluetooth SPP OS 3/4

    - by nigel-jewell
    Hi all, I am in the process of developing an iPhone application that communicates with a number of Bluetooth devices that all support Serial Port Profile - well I assume that it is SPP as they show on my MacBook as Serial Port DevB etc. I understand that iPhone OS 3.x does not support SPP - is that correct? Does anyone know if that has been "fixed" in OS 4? I've seen reports of OS 4 supporting keyboards, but is that a locked version of HID, or will SPP be available via the SDK? Kind Regards, Nige.

    Read the article

  • Home networking problem between power line communication and Ethernet

    - by pixeline
    My network runs through the electrical wiring of the house and is organised as such: Groundfloor: an ADSL+network switch, using DHCP (address : 172.19.3.1) (Mac) PCs connected via an electrical adapter (model: D-Link DHP-200) (1 per PC) First Floor: 1 switch (8 ports) connected via an electrical adapter (model: D-Link DHP-200) (address unknown) 2 Mac PCs connected (via RJ45 network wires) to that router using DHCP The Problem On the first floor, file tranfers between PCs are fast and perfect. But if I try to transfer files from or to a computer on the ground floor, the speed is slow and eventually the transfer dies out. The Question So I suspect the 1st floor switch is creating some kind of barrier (firewall?) preventing external PCs from accessing the PCs it is connected to? Am I right and if so, how could I disable that barrier?

    Read the article

  • Networking setup for three systems

    - by srihari
    Hi, I want to setup a client server environment. I have three systems one with Solaris and the other two with windows. I want to install all the database and other software on the Server and enable the client systems a limited access to the system resources. Can anyone help me how to setup this and also the hardware requirements to setup such an environment. Your replies will be mostly appreciable and helpful to others who has similar thoughts or requirements. As we have more programmatical knowledge and less networking knowledge ,please explain in detail Please provide any vedio tutorials links or documents which will be helpfull in this regard.

    Read the article

  • Brainstorming - MIDI over LAN

    - by Hunter Bridges
    I'm planning out a summer coding project for myself. I work with a lot of MIDI and have been researching it a lot. I know it's an old technology, but it works with a lot of music hardware/software so in my eyes, it's still viable. Anyway, I haven't ever worked with writing drivers or anything, so I don't know where I would start with this. So, provided I have MIDI data already being sent over LAN to a server (I know how to do that part), what steps would it take for the server to channel those received messages to an emulated MIDI device, that could then be accessed in music software and so on? Also, what would it take to also send MIDI data back through the LAN to be received by the device that originally received the message? I'm not really looking for too specific a solution. Really I am just trying to come up with a game plan right now and I need to figure out where/what to research.

    Read the article

  • Local area network computer to computer backup software

    - by thegreyspot
    Hi! I would like to back up my other computers on my local home network to my computer. What software would you suggest? I liked crashplan, however their confusing UI, and its ability not to sync, turned me away. But it has the right idea. A bonus would be if the software did not compile everything in to one file, but its ok if it does. Also I would like it to be free

    Read the article

  • 10/100 Network performing at 1.5 to 2.0 megabyte per second - is that below normal?

    - by burnt1ce
    This comes out to about 12 to 16 megabit/seond. I've read in forums that people are getting much higher speeds (ie: "40-60 Mb/s" http://forums.cnet.com/5208-7589_102-0.html?threadID=265967). I'm getting my benchmark by having a unmanged 5 port switch connected to a WRT54GS router connect. I'm sending a file from a computer connect to the WRT54GS to another computer that's connect to the unmanaged 5 port switch. Is the linkage of the switch causing this massive overhead? i doubt it. What could explain the slow down? electrical interference?

    Read the article

  • Unable to access local network when Cisco VPN client is connected

    - by bryanroth
    I'm a developer and don't have much networking expertise, so bear with me. I'm using the Cisco VPN Client 5.0.02.0090 to connect to my work's VPN that way I can RDP into my work computer. Once connected, I can't ping anything on the local network once connected to the VPN thus I am unable to access my work's network. This used to work about two weeks ago but abruptly stopped working today. However, I have the Cisco VPN Client installed on my laptop and I am able to ping and RDP into my work computer from there. Both my desktop and laptop computers are connected to the same router at home. I have tried the following so far: Rebooted my computer Reinstalled VPN client Updated NIC drivers Disabled firewall Opened up ports 500, 4500, and 10000 Any help would be much appreciated. Thanks!

    Read the article

< Previous Page | 24 25 26 27 28 29 30 31 32 33 34 35  | Next Page >