Search Results

Search found 4620 results on 185 pages for 'serial over lan'.

Page 35/185 | < Previous Page | 31 32 33 34 35 36 37 38 39 40 41 42  | Next Page >

  • How do I know if my serial adapter card is working?

    - by Ingram
    I just installed a 2 port serial adapter in my Ubuntu 10.10 system, then I tried following this tutorial that I used on my old system to connect to a cisco router (my old system had an onboard serial adapter, and the tutorial worked just fine). I can't get my system to connect to the cisco router, so I'm wondering if the card even works in Ubuntu. How can I tell if the card actually works with Ubuntu? #dmesg | grep tty [ 0.000000] console [tty0] enabled [ 0.358667] serial8250: ttyS0 at I/O 0x3f8 (irq = 4) is a 16550A [ 0.358994] 00:0c: ttyS0 at I/O 0x3f8 (irq = 4) is a 16550A [ 0.359128] ttyS1: detected caps 00000700 should be 00000100 [ 0.359132] 0000:03:00.0: ttyS1 at MMIO 0xfeafd000 (irq = 16) is a 16C950/954 [ 0.359191] ttyS2: detected caps 00000700 should be 00000100 [ 0.359195] 0000:03:00.0: ttyS2 at MMIO 0xfeafd200 (irq = 16) is a 16C950/954

    Read the article

  • Reach the same svn repository from a LAN connection and from a external connection

    - by SergioP
    I usually work with a svn repository located in my local office network. Sometimes, when I'm home, I need to connect to my office svn repository. The problem is that, when I'm in office, to reach the svn repo I use an internal LAN IP (like 192.168.1.200), but when I'm home the IP is different, because I reach the server from an externel connection. How can I set up svn to work from my home? Can someone help me? Thanks. Sergio

    Read the article

  • Issue with SPI (Serial Port Comm), stuck on ioctl()

    - by stef
    I'm trying to access a SPI sensor using the SPIDEV driver but my code gets stuck on IOCTL. I'm running embedded Linux on the SAM9X5EK (mounting AT91SAM9G25). The device is connected to SPI0. I enabled CONFIG_SPI_SPIDEV and CONFIG_SPI_ATMEL in menuconfig and added the proper code to the BSP file: static struct spi_board_info spidev_board_info[] { { .modalias = "spidev", .max_speed_hz = 1000000, .bus_num = 0, .chips_select = 0, .mode = SPI_MODE_3, }, ... }; spi_register_board_info(spidev_board_info, ARRAY_SIZE(spidev_board_info)); 1MHz is the maximum accepted by the sensor, I tried 500kHz but I get an error during Linux boot (too slow apparently). .bus_num and .chips_select should correct (I also tried all other combinations). SPI_MODE_3 I checked the datasheet for it. I get no error while booting and devices appear correctly as /dev/spidevX.X. I manage to open the file and obtain a valid file descriptor. I'm now trying to access the device with the following code (inspired by examples I found online). #define MY_SPIDEV_DELAY_USECS 100 // #define MY_SPIDEV_SPEED_HZ 1000000 #define MY_SPIDEV_BITS_PER_WORD 8 int spidevReadRegister(int fd, unsigned int num_out_bytes, unsigned char *out_buffer, unsigned int num_in_bytes, unsigned char *in_buffer) { struct spi_ioc_transfer mesg[2] = { {0}, }; uint8_t num_tr = 0; int ret; // Write data mesg[0].tx_buf = (unsigned long)out_buffer; mesg[0].rx_buf = (unsigned long)NULL; mesg[0].len = num_out_bytes; // mesg[0].delay_usecs = MY_SPIDEV_DELAY_USECS, // mesg[0].speed_hz = MY_SPIDEV_SPEED_HZ; mesg[0].bits_per_word = MY_SPIDEV_BITS_PER_WORD; mesg[0].cs_change = 0; num_tr++; // Read data mesg[1].tx_buf = (unsigned long)NULL; mesg[1].rx_buf = (unsigned long)in_buffer; mesg[1].len = num_in_bytes; // mesg[1].delay_usecs = MY_SPIDEV_DELAY_USECS, // mesg[1].speed_hz = MY_SPIDEV_SPEED_HZ; mesg[1].bits_per_word = MY_SPIDEV_BITS_PER_WORD; mesg[1].cs_change = 1; num_tr++; // Do the actual transmission if(num_tr > 0) { ret = ioctl(fd, SPI_IOC_MESSAGE(num_tr), mesg); if(ret == -1) { printf("Error: %d\n", errno); return -1; } } return 0; } Then I'm using this function: #define OPTICAL_SENSOR_ADDR "/dev/spidev0.0" ... int fd; fd = open(OPTICAL_SENSOR_ADDR, O_RDWR); if (fd<=0) { printf("Device not found\n"); exit(1); } uint8_t buffer1[1] = {0x3a}; uint8_t buffer2[1] = {0}; spidevReadRegister(fd, 1, buffer1, 1, buffer2); When I run it, the code get stuck on IOCTL! I did this way because, in order to read a register on the sensor, I need to send a byte with its address in it and then get the answer back without changing CS (however, when I tried using write() and read() functions, while learning, I got the same result, stuck on them). I'm aware that specifying .speed_hz causes a ENOPROTOOPT error on Atmel (I checked spidev.c) so I commented that part. Why does it get stuck? I though it can be as the device is created but it actually doesn't "feel" any hardware. As I wasn't sure if hardware SPI0 corresponded to bus_num 0 or 1, I tried both, but still no success (btw, which one is it?). UPDATE: I managed to have the SPI working! Half of it.. MOSI is transmitting the right data, but CLK doesn't start... any idea?

    Read the article

  • .NET Serial Port: Port Configuration Dialog

    - by sheepsimulator
    I'm going to be writing a small app based on the .NET SerialPort class. Is there a generic dialog available for setting the port settings, ala baud rate, data bits, stop bit, parity bit, flow control, etc? I didn't see one in the MSDN documentation, but I would think that one exists, since that stuff doesn't change.

    Read the article

  • How to Read Device Data From serial port

    - by Aamir Khurshid
    I have one device which sends data on COM port say on COM13. Now i want to read that data and display it in the RichTextBox or in any text control. I have written the application with the help of IO and IO.Ports but comport.DataRecived event does not fire, even though device is sending data on that port. I have some software on which i define the port number and it successfully display data, which insure me that data is receiving on the Port but i am unable to receive. Is there any way i can read data? comm.Parity = cboParity.Text;//None comm.StopBits = cboStop.Text;//One comm.DataBits = cboData.Text;//8 comm.BaudRate = cboBaud.Text;//9600 comm.DisplayWindow = rtbDisplay;//Null comm.PortName = "COM13"; comm.OpenPort(); cmdOpen.Enabled = false; cmdClose.Enabled = true; cmdSend.Enabled = true; public bool OpenPort() { if (comPort.IsOpen) { comPort.Close(); } comPort.DataReceived += new SerialDataReceivedEventHandler(comPort_DataReceived); comPort.PortName = _portName; comPort.Open();return true; }

    Read the article

  • Document Based Application, preinitialize window (enter serial, buy, trial)

    - by Remizorrr
    I need to create several windows before NSDocument is loaded, or create a window that blocks NSDocument window and top menu. I tried several solutions - but they didn't work right. modal window, one after another. there were some problems with Async URLConnection, and some other problems with my NSDocument content. I created custom MainMenu.xib with no menu, that opens my preinitialize windows. here i found some other problems, when a file(associated with my application) is opened - the Document Window initializes. Here i tried to subclass NSDocumentController, but i found no way to pause the "open document". (i want the document to be opened anyway, but only after the preinitalize windows would be closed). So what is the right way to do this?

    Read the article

  • Using WCF HttpBindings on a LAN

    - by dcw
    We have a WCF-based client server that operates over a LAN. We've been getting along ok by using the NetTcpBinding, chosen because we couldn't get either HttpBinding to work between hosts. (Within a single host works fine, but is not useful for the production environment.) We're now back at the point where we want to explore using either BasicHttpBinding or WsHttpBinding, but we simply can't see the server from the client: even putting in the path to the endpoint into IE fails to see the server. Is there something simple we've overlooked? We're not specifying any security settings (or anything else, for that matter). Should we be doing so (e.g. explicitly setting security settings to None)?

    Read the article

  • serial port does not exist in current context: c#

    - by I__
    here's the code: using System; using System.Collections.Generic; using System.ComponentModel; using System.Data; using System.Drawing; using System.Linq; using System.Text; using System.Windows.Forms; using System.Threading; namespace WindowsFormsApplication1 { public partial class Form1 : Form { public Form1() { InitializeComponent(); } public class ThreadWork { private static SerialPort serialPort1; public static void DoWork() { serialPort1.Open(); serialPort1.Write("AT+CMGF=1\r\n"); //Thread.Sleep(500); serialPort1.Write("AT+CNMI=2,2\r\n"); //Thread.Sleep(500); serialPort1.Write("AT+CSCA=\"+4790002100\"\r\n"); //Thread.Sleep(500); serialPort1.DataReceived += serialPort1_DataReceived_1; } } private void Form1_Load(object sender, EventArgs e) { ThreadStart myThreadDelegate = new ThreadStart(ThreadWork.DoWork); Thread myThread = new Thread(myThreadDelegate); myThread.Start(); } private void serialPort1_DataReceived_1(object sender, System.IO.Ports.SerialDataReceivedEventArgs e) { string response = serialPort1.ReadLine(); this.BeginInvoke(new MethodInvoker(() => textBox1.AppendText(response + "\r\n"))); } } } and i get an error on this line: string response = serialPort1.ReadLine(); it says:: Error 1 The name 'serialPort1' does not exist in the current context C:\Users\alexluvsdanielle\AppData\Local\Temporary Projects\WindowsFormsApplication1\Form1.cs 44 31 WindowsFormsApplication1 what am i doing wrong?

    Read the article

  • deploying a simple html website with eclipse EE & tomcat 7 & router for pc not in LAN

    - by hawkeye
    Hello everyone and thanks for your time, first of all - I want to make a note - I can see the website from my own pc which is the only one connected to the (netgear dgn1000) router, and I can do so with several browsers on my pc, but - when I try and do a port forwarding so that I could access this simple html file (which in the way would use a simple servlet class) I can't seem to view it I have configured my router (both the "services" and the "firewall" sections), and I have also changed my LAN properties according to my ISP's explanation (via phone) : instead of choosing the "obtain an IP address automatically" I have chosen the "use the following IP address, with IP address of 10.0.0.1 (this was also set in the router's port forwarding), Subnet mask of 255.255.255.0, default gateway by checking the same value as seen in the cmd when executing the command ipconfig /all after doing so I've changed the DNS to use the address (just the preferred and not the alternate one) given with the ipconfig /all and still - nothing :/ is it something in my network settings or in my deployment of the eclipse/tomcat ? any help would be greatly appreciated, thanks :)

    Read the article

  • pfsense 2.0.1 Firewall SMB Share not showing up under network

    - by atrueresistance
    I have a freenas NAS with a SMB share running at 192.168.2.2 of a 192.168.2.0/28 network. Gateway is 192.168.2.1. Originally this was running on a switch with my LAN, but now having upgraded to new hardware the Freenas has it's own port on the firewall. Before the switch the freenas would show up under Network on a windows 7 box and an OSX Lion box as freenas{wins} or CIFS shares on freenas{osx} so I know it doesn't have anything do to with the freenas. Here are my pfsense rules. ID Proto Source Port Destination Port Gateway Queue Schedule Description PASS TCP FREENAS net * LAN net 139 (NetBIOS-SSN) * none cifs lan passthrough PASS TCP FREENAS net * LAN net 389 (LDAP) * none cifs lan passthrough PASS TCP FREENAS net * LAN net 445 (MS DS) * none cifs lan passthrough PASS UDP FREENAS net * LAN net 137 (NetBIOS-NS) * none cifs lan passthrough PASS UDP FREENAS net * LAN net 138 (NetBIOS-DGM) * none cifs lan passthrough BLOCK * FREENAS net * LAN net * * none BLOCK * FREENAS net * OPTZONE net * * none BLOCK * FREENAS net * 192.168.2.1 * * none PASS * FREENAS net * * * * none BLOCK * * * * * * none I can connect if I use \\192.168.2.2 and enter the correct login details. I would just like this to show up on the network. Nothing in the log seems to be blocked when I filter by 192.168.2.2. What port am I missing for SMB to show up under the network and not have to connect by IP? ps. Do I really need the LDAP rule?

    Read the article

  • Binary to Ascii and back again

    - by rross
    I'm trying to interface with a hardware device via the serial port. When I use software like Portmon to see the messages they look like this: 42 21 21 21 21 41 45 21 26 21 29 21 26 59 5F 41 30 21 2B 21 27 42 21 21 21 21 41 47 21 27 21 28 21 27 59 5D 41 32 21 2A 21 28 When I run them thru a hex to ascii converter the commands don't make sense. Are these messages in fact something different than hex? My hope was to see the messages the device is passing and emulate them using c#. What can I do to find out exactly what the messages are?

    Read the article

  • Ruby SerialPorts Gem

    - by Seth Archer
    Using Ruby SerialPorts Gem to interact with hardware. When I write a byte array to the hardware using a program called "Serial Port Monitor" the hardware responds correctly. However, when I write the same byte array using ruby it doesn't work unless I do a read request just before the write request. This device doesn't respond correctly with this sp = SerialPort.new(args) sp.write [200.chr, 30.chr, 6.chr, 5.chr, 1.chr, 2.chr, 0.chr, 244.chr] But it does if I add a read request before the write. Like this sp SerialPort.new(args) sp.read sp.write [200.chr, 30.chr, 6.chr, 5.chr, 1.chr, 2.chr, 0.chr, 244.chr] This works, but I'm at a loss as to why. I should also add that the first snippet does work occasionally maybe 1/10 of the time.

    Read the article

  • Java RS232 Comm on Vista-64 bit

    - by DD
    We have a Java application which needs to communicate with a peripheral device over Virtual Serial COM port. We use the RS232 Java COMM API (javax.comm.properties, comm.jar, win32com.dll) to achieve the same. Currently the code works fine on Windows XP 32-bit, Vista 32-bit and Windows 7. However we are having a problem trying to communicate on Vista 64-bit. I read from the Java forums that there is no 64-bit support for the Java COMM API I was wondering if anyone was facing a similar situation and were able to resolve the same in some way?

    Read the article

  • DataReceived Event handler not receiving messages

    - by karthik
    I'm using the below code to receive the messages using serial port event handler. But it dosent receives any.I am not getting errors. The code breaks in "string msg = comport.Readline()" Am i doing something wrong ? public partial class SerialPortScanner : Form { private SerialPort comPort = new SerialPort(); public SerialPortScanner() { InitializeComponent(); comPort.Open(); comPort.DataReceived += new SerialDataReceivedEventHandler(comPort_DataReceived); } void comPort_DataReceived(object sender, SerialDataReceivedEventArgs e) { if (comPort.IsOpen == true) { string msg = comPort.ReadLine(); MessageBox.Show(msg); } } }

    Read the article

  • DataReceived Event handler not receiving messages using c#

    - by karthik
    I'm using the below code to receive the messages using serial port event handler. But it dosent receives any.I am not getting errors. The code breaks in "string msg = comport.Readline()" Am i doing something wrong ? public partial class SerialPortScanner : Form { private SerialPort comPort = new SerialPort(); public SerialPortScanner() { InitializeComponent(); comPort.Open(); comPort.DataReceived += new SerialDataReceivedEventHandler(comPort_DataReceived); } void comPort_DataReceived(object sender, SerialDataReceivedEventArgs e) { if (comPort.IsOpen == true) { string msg = comPort.ReadLine(); MessageBox.Show(msg); } } }

    Read the article

  • Multiple port asynchronous I/O over serialport in C#

    - by firoso
    I'm trying to write a test application for serial I/O (RS-232) with multiple units in C# and I'm running into an issue with my lack of threading experience so I'm soliciting feedback for a best known method. I've got a pool of COM ports COM1-16 each of which can read/write at any time and I need to be able to manage them simultaneously. Is this a situation for a thread pool? What is some guidance on structuring this applet? Edit: Upon review I was wondering is I really even need to do asynchronous threads here, I could just maintain states for each COM-port and do flow logic (i.e., statemachine) for each COM-port individually.

    Read the article

  • programmatically controlling power sockets in the UK

    - by cartoonfox
    It's very simple. I want to plug a lamp into the UK mains supply. I want to be able to power it on and off from software - say from serial port commands, or by running a command-line or something I can get to from ruby or Java. I see lots written about how to do this with X10 with American power systems - but has anybody actually tried doing this in the UK? If you got this working: 1) Exactly what hardware did you use? 2) How do you control it from software? Thanks!

    Read the article

  • Python: Importing a variable inside of a infinite loop

    - by Jack
    I have two modules, a host and a scanner. Both loop indefinitely to communicate with the serial ports. I want to import the variable "bestchannel" from scanner into host but by importing it, the while loop inside scanner runs first and loops forever. I want each module to run separately but be able to send each other data in real time. Is this possible? (outside of scanning ram) Example Code: http://pastebin.com/pxUBaima I want minchannel from scanner to be accessible to host.

    Read the article

  • Run sub on main thread from separate thread [VB.NET|SerialPort]

    - by Steven
    I'm reading data from a serial port, but the DataReceived event of SerialPort is handled on it's own thread. I want to handle this on the main thread, but simply declaring an event and raising it still results in it being processed on the SerialPort thread. I'm assuming I need to declare a delegate I can call, but I don't see how that would work. For example, I want to call Sub HandleDataReceived() on the main thread from the DataReceived thread, having HandleDataReceived() run on the main thread. How would I do this?

    Read the article

  • Dynamically find other hosts in a LAN in Java

    - by Federico Cristina
    A while ago I developed a little LAN chat app. in Java which allows chatting with other hosts, send images, etc. Although it was created just for fun, now it's being used where I work. Currently, there is no "chat server" on the app. where each client registers, updates it's status, etc. (I liked the idea of symmetric design and not depending on a server running on some other machine). Instead, each host is a client/server which has a hosts.properties file with the hostname of the other hosts, and - for instance - broadcasts to each one of them when sending a massive message/image/whatever. In the beginning there were just a couple of hosts, so this hosts.properties file wasn't an issue. But as the amount of users increased, the need of updating that file was a bit daunting. So now I've decided to get rid of it, and each time the app. starts, dynammically find the other active hosts. However, I cannot find the correct way of implement this. I've tried starting different threads, each one of them searching for other hosts in a known range of IP addresses. Something like this (simplified for the sake of readability): /** HostsLocator */ public static void searchForHosts(boolean waitToEnd) { for (int i=0; i < MAX_IP; i+= MAX_IP / threads) { HostsLocator detector = new HostsLocator(i, i+(MAX_IP / threads - 1)); // range: from - to new Thread(detector).start(); } } public void run() { for (int i=from; i<=to; i++) findHosts( maskAddress + Integer.toString(i) ); } public static boolean findHosts(String IP) { InetAddress address = InetAddress.getByName(IP); if ( address.isReachable(CONNECTION_TIME_OUT) ) // host found! } However: With a single thread and a low value in CONNECTION_TIME_OUT (500ms) I get wrong Host Not Found status for for hosts actually active. With a high value in CONNECTION_TIME_OUT (5000ms) and only one single thread takes forever to end With several threads I've also found problems similar like the first one, due to collisions. So... I guess there's a better way of solving this problem but I couldn't find it. Any advice? Thanks!

    Read the article

  • How to make Windows 7 use the internet connection that I specify

    - by user138957
    I have a LAN adapter and a USB wireless internet connection. When both connected windows 7 always uses the USB. I tried changing the metric values but no luck. Let me explains the steps I took. Currently automatic metric on all adapters. LAN connected. ipconfig shows that it is connected to the correct ip/dns/gateway etc. IPv4 Route table shows Metric 24 Then connected USB. ipconfig shows USB connectivity then LAN in that order. Internet is now through USB. IPv4 Route table shows Metric 4249 for LAN and USB is 41. Gateway for USB shows "on-link". netstat -rn shows USBDEVICE on top. Changed LAN metric to 5 and now the route table shows LAN as 9 (not sure why it added 4) and USB as 41. netstat shows LAN then USB. ipconfig shows LAN then USB. But still connection is through USB. How do I know? Task manager shows utilization only through USB as well as speed is showing around 1mbps rather than LANs 10mbps. How can I get win7 use LAN while USB is connected. I am just trying to use USB as a backup just in case I lose LAN connection. Please help!! I thought i will make USB metric manually to say 10. But it says I have to reconnect for it to be effective. Currently USB still shows below LAN and still has 9 and 41 in the table. Disconnected USB. Table shows LAN metric as 24 (Not sure why it got changed from 9 and setting got reverted by to automatic) Reconnected USB. Now in the setting still shows 10 and the route table shows 11 for USB and LAN shows 4249 (settings shows 4245, 4 less)) For some reason restarting USB is resetting LAN setting when reconnected. Thanks

    Read the article

  • How to get virtual com-port number if DBT_DEVNODES_CHANGED event accrues?

    - by Nick Toverovsky
    Hi! Previously I defined com-port number using DBT_DEVICEARRIVAL: procedure TMainForm.WMDEVICECHANGE(var Msg: TWMDeviceChange); var lpdb : PDevBroadcastHdr; lpdbpr: PDevBroadCastPort; S: AnsiString; begin {????????? ?????????} lpdb := PDevBroadcastHdr(Msg.dwData); case Msg.Event of DBT_DEVICEARRIVAL: begin {??????????} if lpdb^.dbch_devicetype = DBT_DEVTYP_PORT {DBT_DEVTYP_DEVICEINTERFACE} then begin lpdbpr:= PDevBroadCastPort(Msg.dwData); S := StrPas(PWideChar(@lpdbpr.dbcp_name)); GetSystemController.Init(S); end; end; DBT_DEVICEREMOVECOMPLETE: begin {????????} if lpdb^.dbch_devicetype = DBT_DEVTYP_PORT then begin lpdbpr:= PDevBroadCastPort(Msg.dwData); S := StrPas(PWideChar(@lpdbpr.dbcp_name)); GetSystemController.ProcessDisconnect(S); end; end; end; end; Unfortunately, the hardware part of a device with which I was working changed and now Msg.Event has value BT_DEVNODES_CHANGED. I've read msdn. It is said that I should use RegisterDeviceNotification to get any additional information. But, if I got it right, it can't be used for serial ports. The DBT_DEVICEARRIVAL and DBT_DEVICEREMOVECOMPLETE events are automatically broadcast to all top-level windows for port devices. Therefore, it is not necessary to call RegisterDeviceNotification for ports, and the function fails if the dbch_devicetype member is DBT_DEVTYP_PORT. So, I am confused. How can I define the com-port of a device, if a get DBT_DEVNODES_CHANGED in WMDEVICECHANGE event?

    Read the article

< Previous Page | 31 32 33 34 35 36 37 38 39 40 41 42  | Next Page >