  • Installing drivers for switchable graphics

    - by Anonymous
    I recently bought a laptop that came with Windows 7 64-bit installed. I have some older (16-bit and 32-bit) software that doesn't work with 64-bit Windows, but works just fine with 32-bit. Since I also wanted to get rid of all of the pre-installed spam, I decided to wipe the hard drive and install a fresh copy of Windows 7 32-bit. I can't get the graphics cards working. This laptop uses switchable graphics, an Intel card and a Radeon card. I first tried installing this driver from Intel, which works for the Intel card. Of course, the Radeon card doesn't work with this driver and I need it for some of the newer games I have. I also tried this driver. Windows's device manager will recognize the Radeon card, but it will still use the Intel card. Also, even though that package says it contains the Intel driver, the Intel card still isn't properly recognized by Windows (leaving me with a nasty 800x600 resolution). On top of that, the Catalyst Control Center won't open (saying "The Catalyst Control Center is not supported by the driver version of your enabled graphics adapter") I tried installing HP's driver then installing Intel's driver on top of it. Device manager will then recognize both graphics cards properly. However, the laptop still uses the Intel card. The CCC still won't start (saying the same thing as before) and I can't find any of 'switching' graphics cards. Before formatting, I could right-click the desktop and click "Configure Switchable Graphics" This option hasn't been in the context menu regardless of what driver(s) I've installed. After some research, I found out that this menu entry runs the command "cli.exe Start PowerXpressHybrid" I've tried manually running this command, but I get the same unsupported message from CCC. So, does anyone know how I can get this working? I would like to be able to switch between the Intel and Radeon. But, if there's some way to disable the Intel and use only the Radeon, that would be fine I dual-boot with Linux (framebuffer uses the Intel, haven't even tried getting X set up yet) Here's the output of lspci # lspci -v | grep VGA 00:02.0 VGA compatible controller: Intel Corporation 2nd Generation Core Processor Family Integrated Graphics Controller (rev 09) (prog-if 00 [VGA controller]) 01:00.0 VGA compatible controller: ATI Technologies Inc NI Seymour [AMD Radeon HD 6470M] (prog-if 00 [VGA controller]) The laptop is a HP Pavilion g6t-1d00. HP doesn't support installing anything but Windows 7 64-bit, so calling tech support isn't an option. Thanks for any help UPDATE: I finally got it working. After a fresh install of Windows 7, I installed the HP driver (the one linked above). Then, there's an optional Windows update I installed (don't remember the exact name, but it'll stick out). After that, graphics switching works just like it's supposed to. Moab, thanks anyways for your help

    Read the article

  • VMware Workstation reboot 32-bit host when starting 32/64-bit guest using VT-x

    - by Powerman
    I'm trying to start 64-bit guest (MacOSX and Windows7) on 32-bit host (Hardened Gentoo Linux, kernel 2.6.28-hardened-r9) using VMware Workstation (6.5.3.185404 and 7.0.1.227600). If VT-X disabled in BIOS, VMware refuse to start 64-bit guest (as expected). If VT-X enabled in BIOS, VMware start guest without complaining, but then, in about a second (I suppose as soon as guest try to switch on 64-bit) my host reboots (actually, it's more like reset - normal reboot procedure skipped and BIOS POST start immediately). My hardware is Core 2 Duo 6600 on ASUS P5B-Deluxe with latest stable BIOS 1101. I've power-cycled system, then enabled Vanderpool in BIOS. My CPU doesn't support Trusted Execution Technology, and there no way to disable it in BIOS. I've rebooted several times after that, sometimes with power-cycled, and ensure Vandertool is enabled in BIOS. I've also run VMware-guest64check-5.5.0-18463 tool, and it report "This host is capable of running a 64-bit guest operating system under this VMware product.". About a year ago I tried to disable hardened in kernel to ensure this isn't because of PaX/GrSecurity, but that doesn't help. I have not checked 32-bit guests with VT-X enabled yet, but without VT-X they works ok. ASUS provide "beta" BIOS updates, but according to their descriptions these updates doesn't fix this issue, so I'm not sure is it good idea to try it. My best guess now it's motherboard/BIOS bug. Any ideas? Update 1: I've tried to boot vt.iso provided at http://communities.vmware.com/docs/DOC-8978 and here is it report: CPU 0: VT is enabled on this core CPU 1: VT is enabled on this core Update 2: I've just tried to boot 32-bit guests (Windows7, Ubuntu9.04 and Gentoo) using all possible virtualization modes. In Automatic, Automatic with Replay, Binary translation everything works, in Intel VT-x/EPT or AMD-V/RVI I got message "This host does not support EPT. Using software virtualization with a software MMU." and everything works. BUT in Intel VT-x or AMD-V mode all 32-bit guests reset host just like 64-bit guests! So, this issue is not specific to 64-bit guests. One more thing. Using Intel VT-x or AMD-V mode for both 32/64-bit guests my host reset right after starting VM, i.e. before VM BIOS POST and before guest even start booting. But using Intel VT-x/EPT or AMD-V/RVI VM BIOS runs ok, then 64-bit guests start booting (Windows7 completed "Loading files" progressbar), and only after that host reset.

    Read the article

  • Laptop LCD sometimes stops working on reboot. Please help.

    - by J Ringle
    I have a Gateway P-6831FX Laptop with Vista Ultimate. The Laptop LCD will sometimes not come on after I reboot the computer. I don't even close the lid and it happens. It isn't dim, it doesn't come on at all. No posting of CMOS (BIOS), nothing. Please note... this happens sometimes, not every time. Frustrating! When plugged into an external monitor, which works fine, Vista display properties can't even "sense" the laptop LCD. I try to enable the laptop LCD for dual display, turning on the laptop LCD, and it does nothing. It's like the laptop LCD is not even there. Manually taking a magnet in my hand to the laptop lid sensing switch (the sensor that turns off display/sleep mode when you close lid), sometimes causes the LCD backlight to "turn on" but not display any images. By "turn on" I mean I can see the screen backlight turn on to a 'dark gray' screen instead of pitch black. Subsequent reboot the laptop display is not working again! Here are the facts: Only happens at random and only after a reboot. Waking from Sleep mode isn't a problem. Pressing F4 function key for dual display does nothing when this happens. Closing lid doesn't seem to be related. (unless it is only after reboot.) using external magnet from laptop screen sensor sometimes triggers backlight to turn on but reboot back to square one with no LCD display. an external display always works fine. I have taken apart LCD, checked all wires and ribbons for loose connections or damage. I have replaced the Inverter. It doesn't seem to be heat related as I can put in sleep mode and resume fine when very hot. (external monitor works fine too). Sometimes the screen works fine as if there is not a problem at all. Even after a reboot... This is random. Any ideas out there? If it is a bad part... which one? The LCD seems to be fine. What are the odds of 2 bad inverters? The backlight is fine. The LCD wires/ribbons seem to be fine. I am at a loss. No warranty left and Gateway tech support is clueless. Thanks for any feedback that might help.

    Read the article

  • which package i should choose, if i want to install virtualenv for python?

    - by hugemeow
    pip search just returns so many matches, i am confused about which package i should choose to install .. should i only install virtualenv? or i'd better also install virtualenv-commands and virtualenv-commands, etc, but i really don't know exactly what virtualenv-commands is ... mirror0@lab:~$ pip search virtualenv virtualenvwrapper - Enhancements to virtualenv virtualenv - Virtual Python Environment builder veh - virtualenv for hg pyutilib.virtualenv - PyUtilib utility for building custom virtualenv bootstrap scripts. envbuilder - A package for automatic generation of virtualenvs virtstrap-core - A bootstrapping mechanism for virtualenv+pip and shell scripts tox - virtualenv-based automation of test activities virtualenvwrapper-win - Port of Doug Hellmann's virtualenvwrapper to Windows batch scripts everyapp.bootstrap - Enhanced virtualenv bootstrap script creation. orb - pip/virtualenv shell script wrapper monupco-virtualenv-python - monupco.com registration agent for stand-alone Python virtualenv applications virtualenvwrapper-powershell - Enhancements to virtualenv (for Windows). A clone of Doug Hellmann's virtualenvwrapper RVirtualEnv - relocatable python virtual environment virtualenv-clone - script to clone virtualenvs. virtualenvcontext - switch virtualenvs with a python context manager lessrb - Wrapper for ruby less so that it's in a virtualenv. carton - make self-extracting virtualenvs virtualenv5 - Virtual Python 3 Environment builder clever-alexis - Clever redhead girl that builds and packs Python project with Virtualenv into rpm, deb, etc. kforgeinstall - Virtualenv bootstrap script for KForge pypyenv - Install PyPy in virtualenv virtualenv-distribute - Virtual Python Environment builder virtualenvwrapper.project - virtualenvwrapper plugin to manage a project work directory virtualenv-commands - Additional commands for virtualenv. rjm.recipe.venv - zc.buildout recipe to turn the entire buildout tree into a virtualenv virtualenvwrapper.bitbucket - virtualenvwrapper plugin to manage a project work directory based on a BitBucket repository tg_bootstrap - Bootstrap a TurboGears app in a VirtualEnv django-env - Automaticly manages virtualenv for django project virtual-node - Install node.js into your virtualenv django-environment - A plugin for virtualenvwrapper that makes setting up and creating new Django environments easier. vip - vip is a simple library that makes your python aware of existing virtualenv underneath. virtualenvwrapper.django - virtualenvwrapper plugin to create a Django project work directory terrarium - Package and ship relocatable python virtualenvs venv_dependencies - Easy to install any dependencies in a virtualenviroment(without making symlinks by hand and etc...) virtualenv-sh - Convenient shell interface to virtualenv virtualenvwrapper.github - Plugin for virtualenvwrapper to automatically create projects based on github repositories. virtualenvwrapper.configvar - Plugin for virtualenvwrapper to automatically export config vars found in your project level .env file. virtualenvwrapper-emacs-desktop - virtualenvwrapper plugin to control emacs desktop mode bootstrapper - Bootstrap Python projects with virtualenv and pip. virtualenv3 - Obsolete fork of virtualenv isotoma.depends.zope2_13_8 - Running zope in a virtualenv virtual-less - Install lessc into your virtualenv virtualenvwrapper.tmpenv - Temporary virtualenvs are automatically deleted when deactivated isotoma.plone.heroku - Tooling for running Plone on heroku in a virtualenv gae-virtualenv - Using virtualenv with zipimport on Google App Engine pinvenv - VirtualEnv plugins for pin isotoma.depends.plone4_1 - Running plone in a virtualenv virtualenv-tools - A set of tools for virtualenv virtualenvwrapper.npm - Plugin for virtualenvwrapper to automatically encapsulate inside the virtual environment any npm installed globaly when the venv is activated d51.django.virtualenv.test_runner - Simple package for running isolated Django tests from within virtualenv difio-virtualenv-python - Difio registration agent for stand-alone Python virtualenv applications VirtualEnvManager - A package to manage various virtual environments. virtualenvwrapper.gem - Plugin for virtualenvwrapper to automatically encapsulate inside the virtual environment any gems installed when the venv is activated

    Read the article

  • GRUB 2 freezing at OS selection screen, what could be the cause?

    - by Michael Kjörling
    Mains power is somewhat unreliable where I live, so every now and then, the computer gets rebooted when the PSU can't maintain proper voltage during a brown-out or momentary black-out. It's happened a few times recently that when power is restored, the BIOS POST completes successfully, GRUB starts to load and then freezes. I've seen this at the Welcome to GRUB! message, but it seems to happen more often just past the switch to the graphical OS list. At this point, the computer will not respond to anything (arrow keys, control commands, Ctrl+Alt+Del, ...) - it simply sits there displaying this image, seemingly doing nothing more. At that point, turning the computer off using the power button and letting it sit for a while (cooling down?) has allowed it to boot successfully. Turning the computer off and immediately back on seems to give the same result (successful POST then freeze in GRUB). This behavior began recently, although does not seem to be directly correlated with my hard disk woes (although it may be relevant that GRUB resides on that physical disk, I don't know). Once the computer has booted, it runs without a hitch. I know that a "proper" solution would be to invest in a UPS, but what might be causing behavior like this? I was thinking in terms of perhaps the CPU shutting down as a thermal control measure, but if that was the cause then wouldn't I see similar freezes during use (which I do not)? What else could cause freezes apparently closely but not perfectly related to the BIOS handover from POST to OS bootloader? The BIOS settings are to reset to previous power status after a power loss. Since the PC in question is almost always turned on, this means restore to full power status. I have no expansion cards installed that make any BIOS extensions known by screen output during the boot process, at least, but I do have a few expansion cards installed. Haven't made any changes in that regard in a long time, now. I haven't touched GRUB itself for a long time, whether configuration or binaries, so I don't think that's the problem. Also, it doesn't really make sense that a bug in GRUB would manifest itself only once in a blue moon but significantly more often after a power failure.

    Read the article

  • Data loss through permissions change?

    - by charliehorse55
    I seem to have deleted some files on my media drive, simply by changing the permissions. The Story I have many operating systems installed on my computer, and constantly switch between them. I bought a 1TB HD and formatted it as HFS+ (not journaled). It worked well between OSX and all of my linux installations while having much better metadata support than NTFS. I never synced the UIDs for my operating systems so the permissions were always doing funny things. Yesterday I tried to fix the permissions by first changing the UIDs of the other operating systems to match OSX, and then changing the file ownership of all files on the drive to match OSX. About 50% of the files on the drive were originally owned by OSX, the other half were owned by the various linux installations. I started to try and change the file permissions for the folders, and that's when it went south. The Commands These commands were run recursively on the one section of the drive. sudo chflags nouchg sudo chflags -N sudo chown myusername sudo chmod 666 sudo chgrp staff The Bad Sometime during the execution of these commands, all of the files belonging to OSX were deleted. If a folder had linux based files it would remain intact but any folder containing exclusively OSX files was erased. If a folder containing linux files also contained a subfolder with only OSX files, the sub folder would remain but is inaccesible and displays a file size of 0 bytes. Luckily these commands were only run on the videos folder, I also have a music folder with the same issue but I did not execute any of these commands on it. Effectively I have examples of the file permissions for all 3 states - the linux files before and after, and the OSX files before. OSX File Before -rw-r--r--@ 1 charliehorse 1000 3634241 15 Nov 2008 /path/to/file com.apple.FinderInfo 32 Linux File before: -rw-r--r--@ 1 charliehorse 1000 5321776 20 Sep 2002 /path/to/file/ com.apple.FinderInfo 32 Linux File After (Read only): (Different file, but I believe the same permissions originally) -rw-rw-rw-@ 1 charliehorse staff 366982610 17 Jun 2008 /path/to/file com.apple.FinderInfo 32 These files still exist so if there are any other commands to run on them to determine what has happened here, I can do that. EDIT Running ls on one of the "empty" deleted OSX folders yields this: ls: .: Permission denied ls: ..: Permission denied ls: subdirA: Permission denied ls: subdirB: Permission denied ls: subdirC: Permission denied ls: subdirD: Permission denied I believe my files might still be there, but the permissions are screwed.

    Read the article

  • Persistent Issues on small business network using Cisco 871W and Catalyst Express 500

    - by Ben Campbell
    Being the most qualified (read: still not qualified) to solve our persistant network issues, I've turned to serverfault for guidance. I've done some searching, reading related documentation on cisco.com and tried a bit of troubleshooting. Here is the config: 100mb synchronous connection from a business internet provider (tested multiple times at 100meg at the source) Cisco 871W wireless point & router is where the WAN connection starts (this serves all our wireless). The only wired connection in the 871W is the Catalyst switch listed below. Cisco Catalyst Express 500 (24TT) is where all the wired connections terminate. About 20 Windows workstations and servers (AD/Webservers only). Some services in EC2 including mail and other web servers/apps. I've been TOLD cabling internally should be gigabit-ready. Here are the problems: generally slow download rates from the internet to the desktop/laptop frequent "page cannot be displayed" errors in browsers-sometimes 3 or 4 reloads are necessary... often times CSS wont load or other content requiring the browser to connect to a different server. slow speed within the LAN from workstation to workstation copying files. I would expect extremely fast data transfer workstation to workstation / server to workstation in this simple network. Several things I need to admit: I'm not primarily a network guy. Funding is relatively low, I need to be the guy that finds the solution. I understand most of the terminology and most of the technology. Implementation is where I fail due to lack of experience. Getting to the point: I'm wondering whether experienced network admins think that our small network should be sufficiently served with our current hardware if configured properly... or if we should purchase new equipment and start fresh? If starting fresh is the plan, whatever that new equipment may be is a likely different question entirely. If I haven't provided enough information, I will happily do some troubleshooting and update with the results. I have experience using wireshark and some other tools. Please let me know what you think would be most helpful and thanks in advance. EDIT: I forgot to add that the Cisco applicance will not finish loading the SDM Express console. It hangs every time at the "populating modules... DHCP". It eventually crashes and closes. I've rebooted the hardware and this still happens.

    Read the article

  • Can an administration extraction of an MSI file perform registry and/or system wide changes?

    - by Wil
    I am always getting MSI (or setup EXEs which are basically MSI) files, and half the time they really do not need to be a setup. Microsoft is probably one of the biggest sources - almost every time I want to download a little source code sample, it has a MSI which if you install, only usually has three files. I would rather not do an install and add it to the add/remove programs and who knows what else (although I am sure it wouldn't be that bad) for the sake of three files! For this reason, I always use the following command: MSIEXEC /a <filename.msi> /qb TARGETDIR=<directory name> Now, this works fine and I have never had problems... However, I was just browsing some articles on Technet and found the following resource about administration installs. Apparently, MSI files can have two sequences: The AdminUISequence Table and the AdminExecuteSequence Table. I am not so worried about the AdminUISequence Table as it states that "The installer skips the actions in this table if the user interface level is set to basic UI or no UI", and this is what the /qb switch I use does. However, there is nothing similar written against AdminExecuteSequence Table. I realise that many people who write MSI files simply do it for a single end user and probably do not even touch the admin install options, however, is it possible for them to set items that can affect the system and if so, is there a fail proof way of extracting? I do already use 7-zip, however despite it being on the "supported" page, MSI support is lacking... well... completely sucks. It looses the file names and is generally useless. They have a bug which was closed with no reason/resolution over three years ago, and I opened a forum post and haven't had a reply. I would not really want to install any additional programs if I could help it and just want peoples opinions on this. Thanks. edit - Should also say, I run with UAC on, and I have never ever had a elevation prompt whilst performing the MSIEXEC operation, so I am guessing I have never had a system wide change, however, I am still curious as to if it is possible... As if changes (even just to the user) are possible I would do this locally/in a VM and never on a server or place of importance!

    Read the article

  • Garbled text in Screen [closed]

    - by Prabin Dahal
    The graphical Interface in my system is garbled with some text. At the beginning I thought it was due to java and tomcat that I installed. But after removing java and tomcat, it is still the same. I am using ubuntu server and i have installed xfce desktop environment with oboard softkey I have added my dmesg output to this message. What is the problem here. I am not able to figure it out. Thank you for your help. Prabin [ 0.390936] usbcore: registered new interface driver usbfs [ 0.391006] usbcore: registered new interface driver hub [ 0.391147] usbcore: registered new device driver usb [ 0.391580] PCI: Using ACPI for IRQ routing [ 0.400509] PCI: pci_cache_line_size set to 64 bytes [ 0.400669] reserve RAM buffer: 000000000009ec00 - 000000000009ffff [ 0.400681] reserve RAM buffer: 000000007f597000 - 000000007fffffff [ 0.400699] reserve RAM buffer: 000000007f6f0000 - 000000007fffffff [ 0.401135] NetLabel: Initializing [ 0.401155] NetLabel: domain hash size = 128 [ 0.401168] NetLabel: protocols = UNLABELED CIPSOv4 [ 0.401212] NetLabel: unlabeled traffic allowed by default [ 0.401466] HPET: 3 timers in total, 0 timers will be used for per-cpu timer [ 0.401494] hpet0: at MMIO 0xfed00000, IRQs 2, 8, 0 [ 0.401520] hpet0: 3 comparators, 64-bit 14.318180 MHz counter [ 0.408228] Switching to clocksource hpet [ 0.434341] AppArmor: AppArmor Filesystem Enabled [ 0.434447] pnp: PnP ACPI init [ 0.434531] ACPI: bus type pnp registered [ 0.434784] pnp 00:00: [bus 00-ff] [ 0.434794] pnp 00:00: [io 0x0cf8-0x0cff] [ 0.434804] pnp 00:00: [io 0x0000-0x0cf7 window] [ 0.434813] pnp 00:00: [io 0x0d00-0xffff window] [ 0.434822] pnp 00:00: [mem 0x000a0000-0x000bffff window] [ 0.434831] pnp 00:00: [mem 0x00000000 window] [ 0.434840] pnp 00:00: [mem 0x80000000-0xffffffff window] [ 0.435018] pnp 00:00: Plug and Play ACPI device, IDs PNP0a08 PNP0a03 (active) [ 0.435526] pnp 00:01: [mem 0xe0000000-0xefffffff] [ 0.435537] pnp 00:01: [mem 0x7f700000-0x7f7fffff] [ 0.435545] pnp 00:01: [mem 0x7f800000-0x7fffffff] [ 0.435554] pnp 00:01: [mem 0xfee00000-0xfeefffff] [ 0.435727] system 00:01: [mem 0xe0000000-0xefffffff] has been reserved [ 0.435754] system 00:01: [mem 0x7f700000-0x7f7fffff] has been reserved [ 0.435775] system 00:01: [mem 0x7f800000-0x7fffffff] has been reserved [ 0.435796] system 00:01: [mem 0xfee00000-0xfeefffff] has been reserved [ 0.435818] system 00:01: Plug and Play ACPI device, IDs PNP0c01 (active) [ 0.436233] pnp 00:02: [io 0x0000-0xffffffffffffffff disabled] [ 0.436245] pnp 00:02: [io 0x0000-0xffffffffffffffff disabled] [ 0.436414] system 00:02: Plug and Play ACPI device, IDs PNP0c02 (active) [ 0.436512] pnp 00:03: [io 0x0060] [ 0.436521] pnp 00:03: [io 0x0064] [ 0.436548] pnp 00:03: [irq 1] [ 0.436682] pnp 00:03: Plug and Play ACPI device, IDs PNP0303 PNP030b (active) [ 0.436825] pnp 00:04: [irq 12] [ 0.436958] pnp 00:04: Plug and Play ACPI device, IDs PNP0f03 PNP0f13 (active) [ 0.437835] pnp 00:05: [io 0x03f8-0x03ff] [ 0.437861] pnp 00:05: [irq 4] [ 0.437870] pnp 00:05: [dma 0 disabled] [ 0.438142] pnp 00:05: Plug and Play ACPI device, IDs PNP0501 (active) [ 0.439014] pnp 00:06: [io 0x02f8-0x02ff] [ 0.439036] pnp 00:06: [irq 3] [ 0.439045] pnp 00:06: [dma 0 disabled] [ 0.439297] pnp 00:06: Plug and Play ACPI device, IDs PNP0501 (active) [ 0.439346] pnp 00:07: [io 0x0000-0x000f] [ 0.439355] pnp 00:07: [io 0x0081-0x0083] [ 0.439363] pnp 00:07: [io 0x0087] [ 0.439371] pnp 00:07: [io 0x0089-0x008b] [ 0.439380] pnp 00:07: [io 0x008f] [ 0.439388] pnp 00:07: [io 0x00c0-0x00df] [ 0.439563] system 00:07: Plug and Play ACPI device, IDs PNP0c01 (active) [ 0.439617] pnp 00:08: [io 0x0070-0x0077] [ 0.439639] pnp 00:08: [irq 8] [ 0.439751] pnp 00:08: Plug and Play ACPI device, IDs PNP0b00 (active) [ 0.439788] pnp 00:09: [io 0x0061] [ 0.439893] pnp 00:09: Plug and Play ACPI device, IDs PNP0800 (active) [ 0.439977] pnp 00:0a: [io 0x0010-0x001f] [ 0.439986] pnp 00:0a: [io 0x0022-0x003f] [ 0.439994] pnp 00:0a: [io 0x0044-0x005f] [ 0.440055] pnp 00:0a: [io 0x0063] [ 0.440063] pnp 00:0a: [io 0x0065] [ 0.440071] pnp 00:0a: [io 0x0067-0x006f] [ 0.440079] pnp 00:0a: [io 0x0072-0x007f] [ 0.440086] pnp 00:0a: [io 0x0080] [ 0.440094] pnp 00:0a: [io 0x0084-0x0086] [ 0.440102] pnp 00:0a: [io 0x0088] [ 0.440109] pnp 00:0a: [io 0x008c-0x008e] [ 0.440117] pnp 00:0a: [io 0x0090-0x009f] [ 0.440125] pnp 00:0a: [io 0x00a2-0x00bf] [ 0.440133] pnp 00:0a: [io 0x00e0-0x00ef] [ 0.440141] pnp 00:0a: [io 0x04d0-0x04d1] [ 0.440150] pnp 00:0a: [io 0x0000-0xffffffffffffffff disabled] [ 0.440160] pnp 00:0a: [io 0x0000-0xffffffffffffffff disabled] [ 0.440168] pnp 00:0a: [io 0x03f4] [ 0.440175] pnp 00:0a: [io 0x03f5] [ 0.440183] pnp 00:0a: [io 0x0374] [ 0.440190] pnp 00:0a: [io 0x0375] [ 0.440405] system 00:0a: [io 0x04d0-0x04d1] has been reserved [ 0.440432] system 00:0a: [io 0x03f4] has been reserved [ 0.440451] system 00:0a: [io 0x03f5] has been reserved [ 0.440469] system 00:0a: [io 0x0374] has been reserved [ 0.440488] system 00:0a: [io 0x0375] has been reserved [ 0.440508] system 00:0a: Plug and Play ACPI device, IDs PNP0c02 (active) [ 0.440550] pnp 00:0b: [io 0x00f0-0x00ff] [ 0.440572] pnp 00:0b: [irq 13] [ 0.440691] pnp 00:0b: Plug and Play ACPI device, IDs PNP0c04 (active) [ 0.440770] pnp 00:0c: [io 0x0810] [ 0.440779] pnp 00:0c: [io 0x0800-0x080f] [ 0.440787] pnp 00:0c: [io 0xffff] [ 0.440947] system 00:0c: [io 0x0810] has been reserved [ 0.440970] system 00:0c: [io 0x0800-0x080f] has been reserved [ 0.440989] system 00:0c: [io 0xffff] has been reserved [ 0.441010] system 00:0c: Plug and Play ACPI device, IDs PNP0c02 (active) [ 0.441620] pnp 00:0d: [io 0x0900-0x097f] [ 0.441630] pnp 00:0d: [io 0x09c0-0x09ff] [ 0.441639] pnp 00:0d: [io 0x0400-0x043f] [ 0.441647] pnp 00:0d: [io 0x0480-0x04bf] [ 0.441656] pnp 00:0d: [mem 0xfec00000-0xfec85fff] [ 0.441664] pnp 00:0d: [mem 0xfed1c000-0xfed1ffff] [ 0.441673] pnp 00:0d: [mem 0x000c0000-0x000dffff] [ 0.441689] pnp 00:0d: [mem 0x000e0000-0x000effff] [ 0.441697] pnp 00:0d: [mem 0x000f0000-0x000fffff] [ 0.441706] pnp 00:0d: [mem 0xff800000-0xffffffff] [ 0.441911] system 00:0d: [io 0x0900-0x097f] has been reserved [ 0.441935] system 00:0d: [io 0x09c0-0x09ff] has been reserved [ 0.441955] system 00:0d: [io 0x0400-0x043f] has been reserved [ 0.441975] system 00:0d: [io 0x0480-0x04bf] has been reserved [ 0.441997] system 00:0d: [mem 0xfec00000-0xfec85fff] could not be reserved [ 0.442019] system 00:0d: [mem 0xfed1c000-0xfed1ffff] has been reserved [ 0.442040] system 00:0d: [mem 0x000c0000-0x000dffff] could not be reserved [ 0.442061] system 00:0d: [mem 0x000e0000-0x000effff] could not be reserved [ 0.442082] system 00:0d: [mem 0x000f0000-0x000fffff] could not be reserved [ 0.442103] system 00:0d: [mem 0xff800000-0xffffffff] has been reserved [ 0.442126] system 00:0d: Plug and Play ACPI device, IDs PNP0c01 (active) [ 0.442308] pnp 00:0e: [mem 0xfed00000-0xfed003ff] [ 0.442454] pnp 00:0e: Plug and Play ACPI device, IDs PNP0103 (active) [ 0.442569] pnp 00:0f: [mem 0x7f6f0000-0x7f6fffff] [ 0.442762] system 00:0f: [mem 0x7f6f0000-0x7f6fffff] has been reserved [ 0.442788] system 00:0f: Plug and Play ACPI device, IDs PNP0c01 (active) [ 0.443360] pnp: PnP ACPI: found 16 devices [ 0.443378] ACPI: ACPI bus type pnp unregistered [ 0.443395] PnPBIOS: Disabled by ACPI PNP [ 0.486106] PCI: max bus depth: 3 pci_try_num: 4 [ 0.486189] pci 0000:00:1c.0: PCI bridge to [bus 01-01] [ 0.486217] pci 0000:00:1c.0: bridge window [io 0xe000-0xefff] [ 0.486241] pci 0000:00:1c.0: bridge window [mem 0xd0100000-0xd01fffff] [ 0.486266] pci 0000:00:1c.0: bridge window [mem 0xff700000-0xff7fffff pref] [ 0.486298] pci 0000:03:01.0: PCI bridge to [bus 04-04] [ 0.486319] pci 0000:03:01.0: bridge window [io 0xd000-0xdfff] [ 0.486348] pci 0000:03:01.0: bridge window [mem 0xd0000000-0xd00fffff] [ 0.486374] pci 0000:03:01.0: bridge window [mem 0xff600000-0xff6fffff 64bit pref] [ 0.486406] pci 0000:03:02.0: PCI bridge to [bus 05-05] [ 0.486444] pci 0000:03:03.0: PCI bridge to [bus 06-06] [ 0.486479] pci 0000:02:00.0: PCI bridge to [bus 03-06] [ 0.486499] pci 0000:02:00.0: bridge window [io 0xd000-0xdfff] [ 0.486522] pci 0000:02:00.0: bridge window [mem 0xd0000000-0xd00fffff] [ 0.486545] pci 0000:02:00.0: bridge window [mem 0xff600000-0xff6fffff 64bit pref] [ 0.486575] pci 0000:00:1c.1: PCI bridge to [bus 02-06] [ 0.486593] pci 0000:00:1c.1: bridge window [io 0xd000-0xdfff] [ 0.486615] pci 0000:00:1c.1: bridge window [mem 0xd0000000-0xd00fffff] [ 0.486637] pci 0000:00:1c.1: bridge window [mem 0xff600000-0xff6fffff pref] [ 0.486710] pci 0000:00:1c.0: PCI INT A -> GSI 16 (level, low) -> IRQ 16 [ 0.486735] pci 0000:00:1c.0: setting latency timer to 64 [ 0.486774] pci 0000:00:1c.1: PCI INT B -> GSI 17 (level, low) -> IRQ 17 [ 0.486796] pci 0000:00:1c.1: setting latency timer to 64 [ 0.486817] pci 0000:02:00.0: setting latency timer to 64 [ 0.486836] pci 0000:03:01.0: setting latency timer to 64 [ 0.486858] pci 0000:03:02.0: setting latency timer to 64 [ 0.486880] pci 0000:03:03.0: setting latency timer to 64 [ 0.486893] pci_bus 0000:00: resource 4 [io 0x0000-0x0cf7] [ 0.486902] pci_bus 0000:00: resource 5 [io 0x0d00-0xffff] [ 0.486912] pci_bus 0000:00: resource 6 [mem 0x000a0000-0x000bffff] [ 0.486922] pci_bus 0000:00: resource 7 [mem 0x80000000-0xffffffff] [ 0.486932] pci_bus 0000:01: resource 0 [io 0xe000-0xefff] [ 0.486941] pci_bus 0000:01: resource 1 [mem 0xd0100000-0xd01fffff] [ 0.486951] pci_bus 0000:01: resource 2 [mem 0xff700000-0xff7fffff pref] [ 0.486961] pci_bus 0000:02: resource 0 [io 0xd000-0xdfff] [ 0.486970] pci_bus 0000:02: resource 1 [mem 0xd0000000-0xd00fffff] [ 0.486980] pci_bus 0000:02: resource 2 [mem 0xff600000-0xff6fffff pref] [ 0.486989] pci_bus 0000:03: resource 0 [io 0xd000-0xdfff] [ 0.486998] pci_bus 0000:03: resource 1 [mem 0xd0000000-0xd00fffff] [ 0.487008] pci_bus 0000:03: resource 2 [mem 0xff600000-0xff6fffff 64bit pref] [ 0.487018] pci_bus 0000:04: resource 0 [io 0xd000-0xdfff] [ 0.487028] pci_bus 0000:04: resource 1 [mem 0xd0000000-0xd00fffff] [ 0.487038] pci_bus 0000:04: resource 2 [mem 0xff600000-0xff6fffff 64bit pref] [ 0.487177] NET: Registered protocol family 2 [ 0.487405] IP route cache hash table entries: 32768 (order: 5, 131072 bytes) [ 0.488397] TCP established hash table entries: 131072 (order: 8, 1048576 bytes) [ 0.489792] TCP bind hash table entries: 65536 (order: 7, 524288 bytes) [ 0.490493] TCP: Hash tables configured (established 131072 bind 65536) [ 0.490525] TCP reno registered [ 0.490551] UDP hash table entries: 512 (order: 2, 16384 bytes) [ 0.490590] UDP-Lite hash table entries: 512 (order: 2, 16384 bytes) [ 0.490898] NET: Registered protocol family 1 [ 0.490970] pci 0000:00:02.0: Boot video device [ 0.491052] pci 0000:00:1d.0: PCI INT A -> GSI 20 (level, low) -> IRQ 20 [ 0.491092] pci 0000:00:1d.0: PCI INT A disabled [ 0.491134] pci 0000:00:1d.1: PCI INT B -> GSI 21 (level, low) -> IRQ 21 [ 0.491174] pci 0000:00:1d.1: PCI INT B disabled [ 0.491220] pci 0000:00:1d.2: PCI INT C -> GSI 22 (level, low) -> IRQ 22 [ 0.491259] pci 0000:00:1d.2: PCI INT C disabled [ 0.491307] pci 0000:00:1d.7: PCI INT D -> GSI 23 (level, low) -> IRQ 23 [ 0.864431] Freeing initrd memory: 13820k freed [ 2.088042] pci 0000:00:1d.7: EHCI: BIOS handoff failed (BIOS bug?) 01010001 [ 2.088207] pci 0000:00:1d.7: PCI INT D disabled [ 2.088267] PCI: CLS 64 bytes, default 64 [ 2.089248] audit: initializing netlink socket (disabled) [ 2.089287] type=2000 audit(1349363630.084:1): initialized [ 2.144783] highmem bounce pool size: 64 pages [ 2.144808] HugeTLB registered 2 MB page size, pre-allocated 0 pages [ 2.160057] VFS: Disk quotas dquot_6.5.2 [ 2.160232] Dquot-cache hash table entries: 1024 (order 0, 4096 bytes) [ 2.161716] fuse init (API version 7.17) [ 2.161995] msgmni has been set to 1713 [ 2.162925] Block layer SCSI generic (bsg) driver version 0.4 loaded (major 253) [ 2.163008] io scheduler noop registered [ 2.163023] io scheduler deadline registered [ 2.163048] io scheduler cfq registered (default) [ 2.163339] pcieport 0000:00:1c.0: setting latency timer to 64 [ 2.163530] pcieport 0000:00:1c.1: setting latency timer to 64 [ 2.163706] pcieport 0000:02:00.0: setting latency timer to 64 [ 2.163873] pcieport 0000:03:01.0: setting latency timer to 64 [ 2.163964] pcieport 0000:03:01.0: irq 40 for MSI/MSI-X [ 2.164193] pcieport 0000:03:02.0: setting latency timer to 64 [ 2.164272] pcieport 0000:03:02.0: irq 41 for MSI/MSI-X [ 2.164453] pcieport 0000:03:03.0: setting latency timer to 64 [ 2.164531] pcieport 0000:03:03.0: irq 42 for MSI/MSI-X [ 2.164783] pcieport 0000:00:1c.0: Signaling PME through PCIe PME interrupt [ 2.164801] pci 0000:01:00.0: Signaling PME through PCIe PME interrupt [ 2.164816] pcie_pme 0000:00:1c.0:pcie01: service driver pcie_pme loaded [ 2.164853] pcieport 0000:00:1c.1: Signaling PME through PCIe PME interrupt [ 2.164867] pcieport 0000:02:00.0: Signaling PME through PCIe PME interrupt [ 2.164880] pcieport 0000:03:01.0: Signaling PME through PCIe PME interrupt [ 2.164892] pci 0000:04:00.0: Signaling PME through PCIe PME interrupt [ 2.164904] pcieport 0000:03:02.0: Signaling PME through PCIe PME interrupt [ 2.164917] pcieport 0000:03:03.0: Signaling PME through PCIe PME interrupt [ 2.164932] pcie_pme 0000:00:1c.1:pcie01: service driver pcie_pme loaded [ 2.164988] pci_hotplug: PCI Hot Plug PCI Core version: 0.5 [ 2.165115] pciehp 0000:00:1c.0:pcie04: HPC vendor_id 8086 device_id 8110 ss_vid 8086 ss_did 8119 [ 2.165177] pciehp 0000:00:1c.0:pcie04: service driver pciehp loaded [ 2.165199] pciehp 0000:00:1c.1:pcie04: HPC vendor_id 8086 device_id 8112 ss_vid 8086 ss_did 8119 [ 2.165260] pciehp 0000:00:1c.1:pcie04: service driver pciehp loaded [ 2.165290] pciehp: PCI Express Hot Plug Controller Driver version: 0.4 [ 2.165488] intel_idle: MWAIT substates: 0x3020220 [ 2.165508] intel_idle: v0.4 model 0x1C [ 2.165513] intel_idle: lapic_timer_reliable_states 0x2 [ 2.165519] Marking TSC unstable due to TSC halts in idle states deeper than C2 [ 2.165779] input: Lid Switch as /devices/LNXSYSTM:00/device:00/PNP0C0D:00/input/input0 [ 2.165855] ACPI: Lid Switch [LID] [ 2.165983] input: Power Button as /devices/LNXSYSTM:00/device:00/PNP0C0C:00/input/input1 [ 2.166005] ACPI: Power Button [PWRB] [ 2.173811] thermal LNXTHERM:00: registered as thermal_zone0 [ 2.173829] ACPI: Thermal Zone [TZ00] (48 C) [ 2.174004] thermal LNXTHERM:01: registered as thermal_zone1 [ 2.174018] ACPI: Thermal Zone [TZ01] (34 C) [ 2.174194] thermal LNXTHERM:02: registered as thermal_zone2 [ 2.174207] ACPI: Thermal Zone [TZ02] (34 C) [ 2.174378] thermal LNXTHERM:03: registered as thermal_zone3 [ 2.174392] ACPI: Thermal Zone [TZ03] (34 C) [ 2.174503] ERST: Table is not found! [ 2.174513] GHES: HEST is not enabled! [ 2.174601] isapnp: Scanning for PnP cards... [ 2.176175] Serial: 8250/16550 driver, 32 ports, IRQ sharing enabled [ 2.196702] serial8250: ttyS0 at I/O 0x3f8 (irq = 4) is a 16550A [ 2.292409] serial8250: ttyS1 at I/O 0x2f8 (irq = 3) is a 16550A [ 2.528909] isapnp: No Plug & Play device found [ 2.588733] 00:05: ttyS0 at I/O 0x3f8 (irq = 4) is a 16550A [ 2.624523] 00:06: ttyS1 at I/O 0x2f8 (irq = 3) is a 16550A [ 2.640702] Linux agpgart interface v0.103 [ 2.645138] brd: module loaded [ 2.647452] loop: module loaded [ 2.648149] pata_acpi 0000:00:1f.1: setting latency timer to 64 [ 2.649238] Fixed MDIO Bus: probed [ 2.649315] tun: Universal TUN/TAP device driver, 1.6 [ 2.649327] tun: (C) 1999-2004 Max Krasnyansky <[email protected]> [ 2.649524] PPP generic driver version 2.4.2 [ 2.649824] ehci_hcd: USB 2.0 'Enhanced' Host Controller (EHCI) Driver [ 2.649884] ehci_hcd 0000:00:1d.7: PCI INT D -> GSI 23 (level, low) -> IRQ 23 [ 2.649937] ehci_hcd 0000:00:1d.7: setting latency timer to 64 [ 2.649946] ehci_hcd 0000:00:1d.7: EHCI Host Controller [ 2.650082] ehci_hcd 0000:00:1d.7: new USB bus registered, assigned bus number 1 [ 2.650148] ehci_hcd 0000:00:1d.7: debug port 1 [ 2.654045] ehci_hcd 0000:00:1d.7: cache line size of 64 is not supported [ 2.654093] ehci_hcd 0000:00:1d.7: irq 23, io mem 0xd02c4000 [ 2.668035] ehci_hcd 0000:00:1d.7: USB 2.0 started, EHCI 1.00 [ 2.668392] hub 1-0:1.0: USB hub found [ 2.668413] hub 1-0:1.0: 8 ports detected [ 2.668618] ohci_hcd: USB 1.1 'Open' Host Controller (OHCI) Driver [ 2.668666] uhci_hcd: USB Universal Host Controller Interface driver [ 2.668726] uhci_hcd 0000:00:1d.0: PCI INT A -> GSI 20 (level, low) -> IRQ 20 [ 2.668751] uhci_hcd 0000:00:1d.0: setting latency timer to 64 [ 2.668759] uhci_hcd 0000:00:1d.0: UHCI Host Controller [ 2.668910] uhci_hcd 0000:00:1d.0: new USB bus registered, assigned bus number 2 [ 2.668981] uhci_hcd 0000:00:1d.0: irq 20, io base 0x0000f040 [ 2.669335] hub 2-0:1.0: USB hub found [ 2.669355] hub 2-0:1.0: 2 ports detected [ 2.669508] uhci_hcd 0000:00:1d.1: PCI INT B -> GSI 21 (level, low) -> IRQ 21 [ 2.669531] uhci_hcd 0000:00:1d.1: setting latency timer to 64 [ 2.669538] uhci_hcd 0000:00:1d.1: UHCI Host Controller [ 2.669675] uhci_hcd 0000:00:1d.1: new USB bus registered, assigned bus number 3 [ 2.669739] uhci_hcd 0000:00:1d.1: irq 21, io base 0x0000f020 [ 2.670099] hub 3-0:1.0: USB hub found [ 2.670118] hub 3-0:1.0: 2 ports detected [ 2.670271] uhci_hcd 0000:00:1d.2: PCI INT C -> GSI 22 (level, low) -> IRQ 22 [ 2.670295] uhci_hcd 0000:00:1d.2: setting latency timer to 64 [ 2.670302] uhci_hcd 0000:00:1d.2: UHCI Host Controller [ 2.670435] uhci_hcd 0000:00:1d.2: new USB bus registered, assigned bus number 4 [ 2.670502] uhci_hcd 0000:00:1d.2: irq 22, io base 0x0000f000 [ 2.670869] hub 4-0:1.0: USB hub found [ 2.670888] hub 4-0:1.0: 2 ports detected [ 2.671186] usbcore: registered new interface driver libusual [ 2.671332] i8042: PNP: PS/2 Controller [PNP0303:PS2K,PNP0f03:PS2M] at 0x60,0x64 irq 1,12 [ 2.673408] serio: i8042 KBD port at 0x60,0x64 irq 1 [ 2.673437] serio: i8042 AUX port at 0x60,0x64 irq 12 [ 2.673844] mousedev: PS/2 mouse device common for all mice [ 2.674272] rtc_cmos 00:08: RTC can wake from S4 [ 2.674482] rtc_cmos 00:08: rtc core: registered rtc_cmos as rtc0 [ 2.674529] rtc0: alarms up to one year, y3k, 242 bytes nvram, hpet irqs [ 2.674691] device-mapper: uevent: version 1.0.3 [ 2.674903] device-mapper: ioctl: 4.22.0-ioctl (2011-10-19) initialised: [email protected] [ 2.675024] EISA: Probing bus 0 at eisa.0 [ 2.675037] EISA: Cannot allocate resource for mainboard [ 2.675050] Cannot allocate resource for EISA slot 1 [ 2.675061] Cannot allocate resource for EISA slot 2 [ 2.675072] Cannot allocate resource for EISA slot 3 [ 2.675083] Cannot allocate resource for EISA slot 4 [ 2.675094] Cannot allocate resource for EISA slot 5 [ 2.675105] Cannot allocate resource for EISA slot 6 [ 2.675116] Cannot allocate resource for EISA slot 7 [ 2.675127] Cannot allocate resource for EISA slot 8 [ 2.675137] EISA: Detected 0 cards. [ 2.675161] cpufreq-nforce2: No nForce2 chipset. [ 2.675401] cpuidle: using governor ladder [ 2.675786] cpuidle: using governor menu [ 2.675797] EFI Variables Facility v0.08 2004-May-17 [ 2.676429] TCP cubic registered [ 2.676751] NET: Registered protocol family 10 [ 2.678031] NET: Registered protocol family 17 [ 2.678052] Registering the dns_resolver key type [ 2.678107] Using IPI No-Shortcut mode [ 2.678515] PM: Hibernation image not present or could not be loaded. [ 2.678543] registered taskstats version 1 [ 2.701145] Magic number: 0:84:234 [ 2.701312] rtc_cmos 00:08: setting system clock to 2012-10-04 15:13:51 UTC (1349363631) [ 2.702280] BIOS EDD facility v0.16 2004-Jun-25, 0 devices found [ 2.702294] EDD information not available. [ 2.702858] Freeing unused kernel memory: 740k freed [ 2.703630] Write protecting the kernel text: 5816k [ 2.703692] Write protecting the kernel read-only data: 2376k [ 2.703706] NX-protecting the kernel data: 4424k [ 2.751226] udevd[84]: starting version 175 [ 2.980162] usb 1-1: new high-speed USB device number 2 using ehci_hcd [ 3.001394] r8169 Gigabit Ethernet driver 2.3LK-NAPI loaded [ 3.001474] r8169 0000:01:00.0: PCI INT A -> GSI 16 (level, low) -> IRQ 16 [ 3.001554] r8169 0000:01:00.0: setting latency timer to 64 [ 3.001654] r8169 0000:01:00.0: irq 43 for MSI/MSI-X [ 3.004220] r8169 0000:01:00.0: eth0: RTL8168c/8111c at 0xf8416000, 00:18:92:03:10:46, XID 1c4000c0 IRQ 43 [ 3.004254] r8169 0000:01:00.0: eth0: jumbo features [frames: 6128 bytes, tx checksumming: ko] [ 3.004347] r8169 Gigabit Ethernet driver 2.3LK-NAPI loaded [ 3.005085] r8169 0000:04:00.0: PCI INT A -> GSI 18 (level, low) -> IRQ 18 [ 3.005182] r8169 0000:04:00.0: setting latency timer to 64 [ 3.005292] r8169 0000:04:00.0: irq 44 for MSI/MSI-X [ 3.007187] r8169 0000:04:00.0: eth1: RTL8168c/8111c at 0xf8418000, 00:18:92:03:10:47, XID 1c4000c0 IRQ 44 [ 3.007224] r8169 0000:04:00.0: eth1: jumbo features [frames: 6128 bytes, tx checksumming: ko] [ 3.034417] pata_sch 0000:00:1f.1: version 0.2 [ 3.034518] pata_sch 0000:00:1f.1: setting latency timer to 64 [ 3.036698] scsi0 : pata_sch [ 3.039842] scsi1 : pata_sch [ 3.040913] ata1: PATA max UDMA/100 cmd 0x1f0 ctl 0x3f6 bmdma 0xf060 irq 14 [ 3.040940] ata2: PATA max UDMA/100 cmd 0x170 ctl 0x376 bmdma 0xf068 irq 15 [ 3.131850] Initializing USB Mass Storage driver... [ 3.136405] scsi2 : usb-storage 1-1:1.0 [ 3.136642] usbcore: registered new interface driver usb-storage [ 3.136656] USB Mass Storage support registered. [ 3.524465] usb 3-1: new low-speed USB device number 2 using uhci_hcd [ 3.968144] usb 3-2: new full-speed USB device number 3 using uhci_hcd [ 4.137903] scsi 2:0:0:0: Direct-Access TS TS4GUFM-H 1100 PQ: 0 ANSI: 0 CCS [ 4.140067] sd 2:0:0:0: Attached scsi generic sg0 type 0 [ 4.140590] sd 2:0:0:0: [sda] 8028160 512-byte logical blocks: (4.11 GB/3.82 GiB) [ 4.141597] sd 2:0:0:0: [sda] Write Protect is off [ 4.141618] sd 2:0:0:0: [sda] Mode Sense: 43 00 00 00 [ 4.142974] sd 2:0:0:0: [sda] No Caching mode page present [ 4.143000] sd 2:0:0:0: [sda] Assuming drive cache: write through [ 4.145837] sd 2:0:0:0: [sda] No Caching mode page present [ 4.145858] sd 2:0:0:0: [sda] Assuming drive cache: write through [ 4.147931] sda: sda1 sda2 < sda5 > [ 4.150972] sd 2:0:0:0: [sda] No Caching mode page present [ 4.151001] sd 2:0:0:0: [sda] Assuming drive cache: write through [ 4.151023] sd 2:0:0:0: [sda] Attached SCSI disk [ 4.249168] input: HID 046a:004b as /devices/pci0000:00/0000:00:1d.1/usb3/3-1/3-1:1.0/input/input2 [ 4.249579] generic-usb 0003:046A:004B.0001: input,hidraw0: USB HID v1.11 Keyboard [HID 046a:004b] on usb-0000:00:1d.1-1/input0 [ 4.287805] input: HID 046a:004b as /devices/pci0000:00/0000:00:1d.1/usb3/3-1/3-1:1.1/input/input3 [ 4.289235] generic-usb 0003:046A:004B.0002: input,hidraw1: USB HID v1.11 Mouse [HID 046a:004b] on usb-0000:00:1d.1-1/input1 [ 4.297604] input: EloTouchSystems,Inc Elo TouchSystems 2216 AccuTouch\xffffffc2\xffffffae\xffffffae USB Touchmonitor Interface as /devices/pci0000:00/0000:00:1d.1/usb3/3-2/3-2:1.0/input/input4 [ 4.298913] generic-usb 0003:04E7:0050.0003: input,hidraw2: USB HID v1.00 Pointer [EloTouchSystems,Inc Elo TouchSystems 2216 AccuTouch\xffffffc2\xffffffae\xffffffae USB Touchmonitor Interface] on usb-0000:00:1d.1-2/input0 [ 4.299878] usbcore: registered new interface driver usbhid [ 4.299925] usbhid: USB HID core driver [ 4.352639] EXT4-fs (sda1): INFO: recovery required on readonly filesystem [ 4.352661] EXT4-fs (sda1): write access will be enabled during recovery [ 8.519257] EXT4-fs (sda1): recovery complete [ 8.564389] EXT4-fs (sda1): mounted filesystem with ordered data mode. Opts: (null) [ 14.280922] ADDRCONF(NETDEV_UP): eth0: link is not ready [ 14.280944] ADDRCONF(NETDEV_UP): eth1: link is not ready [ 14.310368] udevd[308]: starting version 175 [ 14.353873] Adding 1045500k swap on /dev/sda5. Priority:-1 extents:1 across:1045500k [ 14.428718] lp: driver loaded but no devices found [ 14.521667] EXT4-fs (sda1): re-mounted. Opts: errors=remount-ro [ 15.073459] [drm] Initialized drm 1.1.0 20060810 [ 15.097073] psb_gfx: module is from the staging directory, the quality is unknown, you have been warned. [ 15.180630] gma500 0000:00:02.0: PCI INT A -> GSI 16 (level, low) -> IRQ 16 [ 15.180648] gma500 0000:00:02.0: setting latency timer to 64 [ 15.182117] Stolen memory information [ 15.182127] base in RAM: 0x7f800000 [ 15.182134] size: 7932K, calculated by (GTT RAM base) - (Stolen base), seems wrong [ 15.182143] the correct size should be: 8M(dvmt mode=3) [ 15.234889] Set up 1983 stolen pages starting at 0x7f800000, GTT offset 0K [ 15.235126] [drm] SGX core id = 0x01130000 [ 15.235135] [drm] SGX core rev major = 0x01, minor = 0x02 [ 15.235143] [drm] SGX core rev maintenance = 0x01, designer = 0x00 [ 15.268796] [Firmware Bug]: ACPI: No _BQC method, cannot determine initial brightness [ 15.269888] acpi device:04: registered as cooling_device2 [ 15.270568] acpi device:05: registered as cooling_device3 [ 15.270947] input: Video Bus as /devices/LNXSYSTM:00/device:00/PNP0A08:00/LNXVIDEO:00/input/input5 [ 15.271238] ACPI: Video Device [GFX0] (multi-head: yes rom: no post: no) [ 15.271424] [drm] Supports vblank timestamp caching Rev 1 (10.10.2010). [ 15.271434] [drm] No driver support for vblank timestamp query. [ 15.374694] type=1400 audit(1349363644.167:2): apparmor="STATUS" operation="profile_load" name="/sbin/dhclient" pid=435 comm="apparmor_parser" [ 15.385518] type=1400 audit(1349363644.179:3): apparmor="STATUS" operation="profile_load" name="/usr/lib/NetworkManager/nm-dhcp-client.action" pid=435 comm="apparmor_parser" [ 15.386369] type=1400 audit(1349363644.179:4): apparmor="STATUS" operation="profile_load" name="/usr/lib/connman/scripts/dhclient-script" pid=435 comm="apparmor_parser" [ 15.677514] r8169 0000:01:00.0: eth0: link down [ 15.694828] ADDRCONF(NETDEV_UP): eth0: link is not ready [ 16.537490] gma500 0000:00:02.0: allocated 800x480 fb [ 16.558066] fbcon: psbfb (fb0) is primary device [ 16.747122] gma500 0000:00:02.0: BL bug: Reg 00000000 save 00000000 [ 16.775550] Console: switching to colour frame buffer device 100x30 [ 16.781804] fb0: psbfb frame buffer device [ 16.781812] drm: registered panic notifier [ 16.870168] [drm] Initialized gma500 1.0.0 2011-06-06 for 0000:00:02.0 on minor 0 [ 16.871166] snd_hda_intel 0000:00:1b.0: power state changed by ACPI to D0 [ 16.871186] snd_hda_intel 0000:00:1b.0: power state changed by ACPI to D0 [ 16.871207] snd_hda_intel 0000:00:1b.0: PCI INT A -> GSI 16 (level, low) -> IRQ 16 [ 16.871284] snd_hda_intel 0000:00:1b.0: setting latency timer to 64 [ 29.338953] r8169 0000:01:00.0: eth0: link up [ 29.339471] ADDRCONF(NETDEV_CHANGE): eth0: link becomes ready [ 31.427223] init: failsafe main process (675) killed by TERM signal [ 31.522411] type=1400 audit(1349363660.316:5): apparmor="STATUS" operation="profile_replace" name="/sbin/dhclient" pid=889 comm="apparmor_parser" [ 31.523956] type=1400 audit(1349363660.316:6): apparmor="STATUS" operation="profile_replace" name="/usr/lib/NetworkManager/nm-dhcp-client.action" pid=889 comm="apparmor_parser" [ 31.524882] type=1400 audit(1349363660.320:7): apparmor="STATUS" operation="profile_replace" name="/usr/lib/connman/scripts/dhclient-script" pid=889 comm="apparmor_parser" [ 31.525940] type=1400 audit(1349363660.320:8): apparmor="STATUS" operation="profile_load" name="/usr/sbin/tcpdump" pid=891 comm="apparmor_parser" [ 34.526445] postgres (1003): /proc/1003/oom_adj is deprecated, please use /proc/1003/oom_score_adj instead. [ 40.144048] eth0: no IPv6 routers present

    Read the article

  • pfSense 2.1 OpenVPN client not using tunnelled interface

    - by Brian M. Hunt
    I'm having some trouble getting OpenVPN working on my pfSense box. The issue is quite strange to me. When I have the OpenVPN turned on, only my router is able to connect to the Internet. From the router I can use ping, links, etc., and connections work exactly as expected - through the VPN, with the IP address assigned by my VPN provider (Proxy.sh, incidentally). However, none of the clients on the local network can connect to the Internet. I get timeouts when using ping or a web browser. I can ping my router, and the IP address of the gateway. When I switch the default gateway from the VPN to my ISP's gateway, all works exactly as expected. Here the routing table (netstat -r) when in VPN mode, and a key for it: IPv4 Destination Gateway Flags Refs Use Mtu Netif Expire 0.0.0.0/1 10.XX.X.53 UGS 0 122 1500 ovpnc1 = default 10.XX.X.53 UGS 0 235 1500 ovpnc1 8.8.8.8 10.XX.X.53 UGHS 0 82 1500 ovpnc1 10.XX.X.1/32 10.11.0.53 UGS 0 0 1500 ovpnc1 10.XX.X.53 link#12 UH 0 0 1500 ovpnc1 10.XX.X.54 link#12 UHS 0 0 16384 lo0 ZZ.XX.XXX.0/20 link#1 U 0 83 1500 re0 ZZ.XX.XXX.XXX link#1 UHS 0 0 16384 lo0 127.0.0.1 link#9 UH 0 12 16384 lo0 128.0.0.0/1 10.11.0.53 UGS 0 123 1500 ovpnc1 192.168.1.0/24 link#11 U 0 1434 1500 ue0 192.168.1.1 link#11 UHS 0 0 16384 lo0 YYY.YYY.YYY.YYY/32 ZZ.XX.XXX.1 UGS 0 249 1500 re0 IP addresses 10.XX.X.53/54 - My DHCP-assigned IP address/pair from the VPN provider ZZ.XX.XXX.XXX - My external IP assigned by my ISP YYY.YYY.YYY.YYY - The external IP assigned by the VPN provider Interfaces ovpnc1 - My VPN client interface re0 - My LAN interface ue0 - My WAN interface This looks essentially what I would expect it to be. The default route is through the VPN provider. The VPN address is routed through the ISP-assigned IP address. I am not sure what would be wrong here. So figuring this was a firewall issue, I basically tried enabling all in/out traffic. This did not seem to remedy the problem. Also figuring it could possibly be some client networking issue, I restarted the clients on the LAN. This did not help. I also ran route flush and reset the routes manually. So I am a bit stumped, and would be very grateful for any thoughts on what the problem might be.

    Read the article

  • Why do I see a large performance hit with DRBD?

    - by BHS
    I see a much larger performance hit with DRBD than their user manual says I should get. I'm using DRBD 8.3.7 (Fedora 13 RPMs). I've setup a DRBD test and measured throughput of disk and network without DRBD: dd if=/dev/zero of=/data.tmp bs=512M count=1 oflag=direct 536870912 bytes (537 MB) copied, 4.62985 s, 116 MB/s / is a logical volume on the disk I'm testing with, mounted without DRBD iperf: [ 4] 0.0-10.0 sec 1.10 GBytes 941 Mbits/sec According to Throughput overhead expectations, the bottleneck would be whichever is slower, the network or the disk and DRBD should have an overhead of 3%. In my case network and I/O seem to be pretty evenly matched. It sounds like I should be able to get around 100 MB/s. So, with the raw drbd device, I get dd if=/dev/zero of=/dev/drbd2 bs=512M count=1 oflag=direct 536870912 bytes (537 MB) copied, 6.61362 s, 81.2 MB/s which is slower than I would expect. Then, once I format the device with ext4, I get dd if=/dev/zero of=/mnt/data.tmp bs=512M count=1 oflag=direct 536870912 bytes (537 MB) copied, 9.60918 s, 55.9 MB/s This doesn't seem right. There must be some other factor playing into this that I'm not aware of. global_common.conf global { usage-count yes; } common { protocol C; } syncer { al-extents 1801; rate 33M; } data_mirror.res resource data_mirror { device /dev/drbd1; disk /dev/sdb1; meta-disk internal; on cluster1 { address 192.168.33.10:7789; } on cluster2 { address 192.168.33.12:7789; } } For the hardware I have two identical machines: 6 GB RAM Quad core AMD Phenom 3.2Ghz Motherboard SATA controller 7200 RPM 64MB cache 1TB WD drive The network is 1Gb connected via a switch. I know that a direct connection is recommended, but could it make this much of a difference? Edited I just tried monitoring the bandwidth used to try to see what's happening. I used ibmonitor and measured average bandwidth while I ran the dd test 10 times. I got: avg ~450Mbits writing to ext4 avg ~800Mbits writing to raw device It looks like with ext4, drbd is using about half the bandwidth it uses with the raw device so there's a bottleneck that is not the network.

    Read the article

  • MySQL: Pacemaker cannot start the failed master as a new slave?

    - by quanta
    I'm going to setup failover for MySQL replication (1 master and 1 slave) follow this guide: https://github.com/jayjanssen/Percona-Pacemaker-Resource-Agents/blob/master/doc/PRM-setup-guide.rst Here're the output of crm configure show: node serving-6192 \ attributes p_mysql_mysql_master_IP="192.168.6.192" node svr184R-638.localdomain \ attributes p_mysql_mysql_master_IP="192.168.6.38" primitive p_mysql ocf:percona:mysql \ params config="/etc/my.cnf" pid="/var/run/mysqld/mysqld.pid" socket="/var/lib/mysql/mysql.sock" replication_user="repl" replication_passwd="x" test_user="test_user" test_passwd="x" \ op monitor interval="5s" role="Master" OCF_CHECK_LEVEL="1" \ op monitor interval="2s" role="Slave" timeout="30s" OCF_CHECK_LEVEL="1" \ op start interval="0" timeout="120s" \ op stop interval="0" timeout="120s" primitive writer_vip ocf:heartbeat:IPaddr2 \ params ip="192.168.6.8" cidr_netmask="32" \ op monitor interval="10s" \ meta is-managed="true" ms ms_MySQL p_mysql \ meta master-max="1" master-node-max="1" clone-max="2" clone-node-max="1" notify="true" globally-unique="false" target-role="Master" is-managed="true" colocation writer_vip_on_master inf: writer_vip ms_MySQL:Master order ms_MySQL_promote_before_vip inf: ms_MySQL:promote writer_vip:start property $id="cib-bootstrap-options" \ dc-version="1.0.12-unknown" \ cluster-infrastructure="openais" \ expected-quorum-votes="2" \ no-quorum-policy="ignore" \ stonith-enabled="false" \ last-lrm-refresh="1341801689" property $id="mysql_replication" \ p_mysql_REPL_INFO="192.168.6.192|mysql-bin.000006|338" crm_mon: Last updated: Mon Jul 9 10:30:01 2012 Stack: openais Current DC: serving-6192 - partition with quorum Version: 1.0.12-unknown 2 Nodes configured, 2 expected votes 2 Resources configured. ============ Online: [ serving-6192 svr184R-638.localdomain ] Master/Slave Set: ms_MySQL Masters: [ serving-6192 ] Slaves: [ svr184R-638.localdomain ] writer_vip (ocf::heartbeat:IPaddr2): Started serving-6192 Editing /etc/my.cnf on the serving-6192 of wrong syntax to test failover and it's working fine: svr184R-638.localdomain being promoted to become the master writer_vip switch to svr184R-638.localdomain Current state: Last updated: Mon Jul 9 10:35:57 2012 Stack: openais Current DC: serving-6192 - partition with quorum Version: 1.0.12-unknown 2 Nodes configured, 2 expected votes 2 Resources configured. ============ Online: [ serving-6192 svr184R-638.localdomain ] Master/Slave Set: ms_MySQL Masters: [ svr184R-638.localdomain ] Stopped: [ p_mysql:0 ] writer_vip (ocf::heartbeat:IPaddr2): Started svr184R-638.localdomain Failed actions: p_mysql:0_monitor_5000 (node=serving-6192, call=15, rc=7, status=complete): not running p_mysql:0_demote_0 (node=serving-6192, call=22, rc=7, status=complete): not running p_mysql:0_start_0 (node=serving-6192, call=26, rc=-2, status=Timed Out): unknown exec error Remove the wrong syntax from /etc/my.cnf on serving-6192, and restart corosync, what I would like to see is serving-6192 was started as a new slave but it doesn't: Failed actions: p_mysql:0_start_0 (node=serving-6192, call=4, rc=1, status=complete): unknown error Here're snippet of the logs which I'm suspecting: Jul 09 10:46:32 serving-6192 lrmd: [7321]: info: rsc:p_mysql:0:4: start Jul 09 10:46:32 serving-6192 lrmd: [7321]: info: RA output: (p_mysql:0:start:stderr) Error performing operation: The object/attribute does not exist Jul 09 10:46:32 serving-6192 crm_attribute: [7420]: info: Invoked: /usr/sbin/crm_attribute -N serving-6192 -l reboot --name readable -v 0 The full logs: http://fpaste.org/AyOZ/ The strange thing is I can starting it manually: export OCF_ROOT=/usr/lib/ocf export OCF_RESKEY_config="/etc/my.cnf" export OCF_RESKEY_pid="/var/run/mysqld/mysqld.pid" export OCF_RESKEY_socket="/var/lib/mysql/mysql.sock" export OCF_RESKEY_replication_user="repl" export OCF_RESKEY_replication_passwd="x" export OCF_RESKEY_test_user="test_user" export OCF_RESKEY_test_passwd="x" sh -x /usr/lib/ocf/resource.d/percona/mysql start: http://fpaste.org/RVGh/ Did I make something wrong?

    Read the article

  • Squid 2.7.STABLE3-4.1 as a transparent proxy on Ubuntu Server 9.04

    - by LOGIC9
    Can't get this to work at all! I'm trying to get this linux box to act as a transparent proxy and, with the help of DHCP, force everyone on the network to gate into the proxy. I have two ethernet connections, both to the same switch. And I'm trying to get 192.168.1.234 to become the default gateway. The actual WAN connection is to a gateway 192.168.1.1. eth0 is 192.168.1.234 eth1 is 192.168.1.2 Effectively I'm trying to make eth0 a LAN only interface and eth1 a WAN interface. I've oi should set the gateway for eth1 to point to 192.168.1.234 my squid.conf file has the following directives added at the bottom: nly set eth0 to have a gateway address in /etc/network/interfaces I'm not sure whether http_port 3128 transparent acl lan src 192.168.1.0/24 acl lh src 127.0.0.1/255.255.255.0 http_access allow lan http_access allow lh i've added the following routing commands: iptables -t nat -A PREROUTING -i eth0 -p tcp -m tcp --dport 80 -j DNAT --to-destination 192.168.1.2:3128 iptables -t nat -A PREROUTING -i eth1 -p tcp -m tcp --dport 80 -j REDIRECT --to-ports 3128 I set a computer with TCP settings 192.168.1.234 as the gateway and opened up google.com, but it comes up with a request error. Any ideas why this isn't working? :( Been searching continuously for a solution to no avail. ----------------------------- EDIT ------------------------------- Managed to get it to route properly to the squid, here's the error I get in the browser: ERROR The requested URL could not be retrieved While trying to process the request: GET / HTTP/1.1 Host: www.google.com User-Agent: Mozilla/5.0 (Windows; U; Windows NT 5.1; en-GB; rv:1.9.1.2) Gecko/20090729 Firefox/3.5.2 Accept: text/html,application/xhtml+xml,application/xml;q=0.9,*/*;q=0.8 Accept-Language: en-gb,en;q=0.5 Accept-Encoding: gzip,deflate Accept-Charset: ISO-8859-1,utf-8;q=0.7,*;q=0.7 Keep-Alive: 300 Connection: keep-alive Cache-Control: max-age=0 The following error was encountered: * Invalid Request Some aspect of the HTTP Request is invalid. Possible problems: * Missing or unknown request method * Missing URL * Missing HTTP Identifier (HTTP/1.0) * Request is too large * Content-Length missing for POST or PUT requests * Illegal character in hostname; underscores are not allowed Your cache administrator is webmaster. Generated Mon, 26 Oct 2009 03:41:15 GMT by mjolnir.lloydharrington.local (squid/2.7.STABLE3)

    Read the article

  • SMPS stops when I plug in a SATA drive?

    - by claws
    Hello, Part 1: my first question is all the 4 wire power connectors (intended for hardisks/dvd drives not mother board) are same. Right? I've been using all of them same and I had no problem for years. Yesterday I borrowed a SATA disk from my friend and connected it my computer using Sata Power adaptor (4 wire) and when I switched on the computer. There were fumes coming out of the connector. I immediately turned it off (in just one second). I tested the voltages in the 4 wire power connector of my SMPS: They were 5.3v & 12.2V. I couldn't measure the current. But my SMPTS label reads: DC Output: 3.3v (25A) +5v (32A) -5v (0.3A) +12V (17A) -12V (0.8A) And the SATA hardisk label reads Input: +5v (0.72A) +12V (0.52A) I'm shocked! I never noticed this. Does the "sata power adaptor" scale down the current to required? If it doesn't, I've been connecting same way for years. I never had any problem. This is the first time I'm encountering it. Part 2: I wanted to return the drive to my friend. He has two hard disks, SATA & PATA. Its the SATA that I borrowed. When he usually switches on. The CPU fan starts & then stops for a sec and starts again and continues working. That was the earlier situation. I don't know why it stops & starts? Well, Now when I connect this SATA disk and switch ON the computer. CPU fan starts (just for an instant, not even a 0.5 sec) and stops. It doesn't start again, I mean the power from SMPS has stopped. But if I disconnect this SATA disk. It works fine. What seems to be the problem? I've no idea about why there were fumes or why his SMPS starts & stops giving power? What is its relation with the SATA disk connection?

    Read the article

  • Snmpd update interface counters slowly or something like this

    - by Korjavin Ivan
    I update one my freebsd box to 9-stable (totally new installation) and install net-snmp for monitoring. uname -r 9.1-PRERELEASE pkg_info net-snmp-5.7.1_7 Information for net-snmp-5.7.1_7: Comment: An extendable SNMP implementation .... cat /var/db/ports/net-snmp/options # This file is auto-generated by 'make config'. # Options for net-snmp-5.7.1_7 _OPTIONS_READ=net-snmp-5.7.1_7 _FILE_COMPLETE_OPTIONS_LIST= IPV6 MFD_REWRITES PERL PERL_EMBEDDED PYTHON DUMMY TKMIB DMALLOC MYSQL AX_SOCKONLY UNPRIVILEGED OPTIONS_FILE_UNSET+=IPV6 OPTIONS_FILE_UNSET+=MFD_REWRITES OPTIONS_FILE_SET+=PERL OPTIONS_FILE_SET+=PERL_EMBEDDED OPTIONS_FILE_UNSET+=PYTHON OPTIONS_FILE_SET+=DUMMY OPTIONS_FILE_UNSET+=TKMIB OPTIONS_FILE_SET+=DMALLOC OPTIONS_FILE_UNSET+=MYSQL OPTIONS_FILE_UNSET+=AX_SOCKONLY OPTIONS_FILE_UNSET+=UNPRIVILEGED I have about 500 vlan on this machine, and collect info about interface through snmpd to 2 different software, zabbix and cacti. And both of them plot the graphs with blank fields. I tryed change polling time in zabbix, from 15, sec to 30,60,90,120,10. And anyway i have blank fields. snmpd.conf is empty - only a access controls. This configuration worked fine on freebsd 8. Where is my fault? How fix this graphs? UPD: Changing pooling time, switch off one of agent, doesnt help. I look at zabbix log (recieved data from snmpd) and see that: sorry for russian locale, just look at numbers: and thats is not true, as my "iftop" show speed was about 90Mbits, but snmpd return 2Mbits. I understand that snmpd doesnt return speed, it return just a counter. But how its possible? why 2Mbit/s ? I tryed recompile snmpd with 64-bit counters, and without it. In both variants this blank fields present. So i think its my OS (freebsd) doesnt update interface counters well. I still collect tcpdump for found this request/response. But have problem with that, to much trash. UPD2: I decrypt tcpdump-ed file, and public this as google doc at gdocfile Timediff looks strange.. Like zabbix sometimes "forget" do request, and then do twice at row, ehh UPD3: I parse log from command "while true; do netstat -bin -I vlan4008 /var/log/netstat; sleep 300; done" and load as google docs, and add formula for speed : link Looks like all counters in OS are good. Now i think problem in : 1. zabbix get request twice at row (and what about cacti) 2. snmpd use counter32

    Read the article

  • Parsing xml files locally from assets folder using XmlPullParser

    - by Randolphg
    Im trying to parse a local xml file that I place in my assets folder. I've been trying to do this for almost a week now. Here is my test xml file Test1 Test2 Test3 Test4 Test5 I keep getting the same error: W/System.err(22458): org.xmlpull.v1.XmlPullParserException: unexpected type (position:TEXT Code: public void xmlParser() throws XmlPullParserException, IOException, ParserConfigurationException, SAXException { Log.d("tag", "xmlParsing...."); Arithmetic arthm = new Arithmetic(); XmlPullParserFactory xmlPF = XmlPullParserFactory.newInstance(); xmlPF.setValidating(false); XmlPullParser xml = xmlPF.newPullParser(); InputStream raw = getApplication().getAssets().open("menu.xml"); xml.setInput(raw, null); xml.nextTag(); Log.d("tag", "start parsing...."); String elementText = null; String elemName = null; int nofTags = 0; while (xml.getEventType() != XmlPullParser.END_DOCUMENT) { Log.d("tag", "while(xml.next)..."); switch (xml.getEventType()) { case XmlPullParser.START_DOCUMENT: Log.d("tag", "while (xml.getEventType() != XmlPullParser.END_DOCUMENT)"); break; case XmlPullParser.START_TAG: Log.d("tag", " case XmlPullParser.START_TAG"); elementText = xml.getName(); Log.d("tag", "elementText = " + elementText); if (xml.getEventType() != XmlPullParser.END_TAG) { xml.nextTag(); } break; case XmlPullParser.TEXT: Log.d("tag", "case TEXT"); if (elementText.equals("menu") && xml.isWhitespace()) { Log.d("tag", "<" + elementText + ">"); arthm.menu_name = xml.getText(); Log.d("tag", "value " + xml.getText() + " added"); } else if (elementText.equals("item")) { arthm.description = xml.getText(); Log.d("tag", "value " + xml.getText() + " added"); } else if (elementText.equals("SUBCATEGORY NAME")) { arthm.subcategoryDesc.add(xml.getText()); Log.d("tag", "value " + xml.getText() + " added"); } else if (elementText.equals("SUBCATEGORY DESC")) { arthm.subcategoryName.add(xml.getText()); Log.d("tag", "value " + xml.getText() + " added"); } break; case XmlPullParser.END_TAG: Log.d("tag", "case END_TAG"); nofTags += 1; String tags = Integer.toString(nofTags); Log.d("tags", elementText + " number of tags" + tags); if (xml.nextTag() != XmlPullParser.START_TAG) { xml.next(); } break; case XmlPullParser.END_DOCUMENT: Log.d("tag", "case END_DOCUMENT"); break; default: break; } } Log.d("tag", "Success!"); } Thanks in advance.

    Read the article

  • Detach current session and attach to another session, done with one script, can I?

    - by Jimm Chen
    After reading the vague official doc of GNU screen( http://www.gnu.org/software/screen/manual/screen.html ) and asking quite some questions at this site. I still cannot figure out how to accomplish such a task with a shell script. This task costs some words to describe. Assume I'm using PuTTY to telnet into my Linux server. ?STEP 1? Launch 2 telnet connections . From putty window 1 (PTWIN1),telnet into Linux Bash shell, execute screen -RR to launch a screen session, and get session name 21385.pts-4.linux-ic37 . From putty window 2 (PTWIN2), do that same as in PTWIN1, but this time, I get session name 22041.pts-9.linux-ic37 . Now, we have two screen sessions running simultaneously. We can check this: $ screen -ls There are screens on: 22041.pts-9.linux-ic37 (Attached) 21385.pts-4.linux-ic37 (Attached) 2 Sockets in /var/run/uscreens/S-chj2. ?STEP 2? Assume that for some reason, PTWIN1's TCP connection is lost abnormally(but server doesn't know that), and an urgent work is pending on session 21385 and I want to quickly regain control of it. Fortunately, we know the 21385 session is still there, so, I want to have PTWIN2 attach to session 21385. Because I hate to remember the esoteric screen option all the time, so I decide to write a script called sttach. I hope that sttach 21385.pts-4.linux-ic37 can let me attach to session 21385(for PTWIN2). Now, let's say sttach works well and I take control of 21385 on PTWIN2. ?STEP 3? Some minutes later. I want to go back to work on session 22041. Here, please allow me to have PTWIN2 remain associated with session 21385. What I would like to do is to launch another putty window (PTWIN3), telnet into server, and execute sttach 22041.pts-9.linux-ic37 in hope that I can resume session 22041 on PTWIN3 . You can see the benefit of sttach: as long as I know the target session name, I can call it to have my PuTTY window switch to that session, regardless whether the target session is "(Attached)" or "(Detached)", and regardless whether the running context is inside a screen session or not. Now the question: How to write the (Bash) script sttach? I mean, run screen with appropriate options in sttach to accomplish the goal. Waiting for your kind answer. Thank you. My previous questions regarding GNU screen: GNU screen, how to get current sessionname programmatically Is it possible to change GNU screen session name after created? How do I know I'm running inside a linux "screen" or not? My env: openSUSE Linux 11.3, GNU screen 4.00.03 (FAU) 23-Oct-06

    Read the article

  • Open ports broken from internal network

    - by ksvi
    Quick summary: Forwarded port works from the outside world, but from the internal network using the external IP the connection is refused. This is a simplified situation to make the explanation easier: I have a computer that is running a service on port 12345. This computer has an internal IP 192.168.1.100 and is connected directly to a modem/router which has internal IP 192.168.1.1 and external (public, static) IP 1.2.3.4. (The router is TP-LINK TD-w8960N) I have set up port forwarding (virtual server) at port 12345 to go to port 12345 at 192.168.1.100. If I run telnet 192.168.1.100 12345 from the same computer everything works. But running telnet 1.2.3.4 12345 says connection refused. If I do this on another computer (on the same internal network, connected to the router) the same thing happens. This would seem like the port forwarding is not working. However... If I run a online port checking service on my external IP and the service port it says the port is open and I can see the remote server connecting and immediately closing connection. And using another computer that is connected to the internet using a mobile connection I can also use telnet 1.2.3.4 12345 and I get a working connection. So the port forwarding seems to be working, however using external IP from the internal network doesn't. I have no idea what can be causing this, since another setup very much like this (different router) works for me. I can access a service running on a server from inside the network both through the internal and external IP. Note: I know I could just use the internal IP inside of the network to access this service. But if I have a laptop that must be able to do this both from inside and outside it would be annoying to constantly switch between 1.2.3.4 and 192.168.1.100 in the software configuration. Router output: > iptables -t nat -L -n Chain PREROUTING (policy ACCEPT) target prot opt source destination ACCEPT all -- 0.0.0.0/0 224.0.0.0/3 DNAT tcp -- 0.0.0.0/0 0.0.0.0/0 tcp dpt:25 to:192.168.1.101 DNAT udp -- 0.0.0.0/0 0.0.0.0/0 udp dpt:25 to:192.168.1.101 DNAT tcp -- 0.0.0.0/0 0.0.0.0/0 tcp dpt:110 to:192.168.1.101 DNAT tcp -- 0.0.0.0/0 0.0.0.0/0 tcp dpt:12345 to:192.168.1.102 DNAT udp -- 0.0.0.0/0 192.168.1.1 udp dpt:53 to:217.118.96.203 Chain POSTROUTING (policy ACCEPT) target prot opt source destination MASQUERADE all -- 192.168.1.0/24 0.0.0.0/0 Chain OUTPUT (policy ACCEPT) target prot opt source destination

    Read the article

  • Persuading openldap to work with SSL on Ubuntu with cn=config

    - by Roger
    I simply cannot get this (TLS connection to openldap) to work and would appreciate some assistance. I have a working openldap server on ubuntu 10.04 LTS, it is configured to use cn=config and most of the info I can find for TLS seems to use the older slapd.conf file :-( I've been largely following the instructions here https://help.ubuntu.com/10.04/serverguide/C/openldap-server.html plus stuff I've read here and elsewhere - which of course could be part of the problem as I don't totally understand all of this yet! I have created an ssl.ldif file as follows; dn:cn=config add: olcTLSCipherSuite olcTLSCipherSuite: TLSV1+RSA:!NULL add: olcTLSCRLCheck olcTLSCRLCheck: none add: olcTLSVerifyClient olcTLSVerifyClient: never add: olcTLSCACertificateFile olcTLSCACertificateFile: /etc/ssl/certs/ldap_cacert.pem add: olcTLSCertificateFile olcTLSCertificateFile: /etc/ssl/certs/my.domain.com_slapd_cert.pem add: olcTLSCertificateKeyFile olcTLSCertificateKeyFile: /etc/ssl/private/my.domain.com_slapd_key.pem and I import it using the following command line ldapmodify -x -D cn=admin,dc=mydomain,dc=com -W -f ssl.ldif I have edited /etc/default/slapd so that it has the following services line; SLAPD_SERVICES="ldap:/// ldapi:/// ldaps:///" And everytime I'm making a change, I'm restarting slapd with /etc/init.d/slapd restart The following command line to test out the non TLS connection works fine; ldapsearch -d 9 -D cn=admin,dc=mydomain,dc=com -w mypassword \ -b dc=mydomain,dc=com -H "ldap://mydomain.com" "cn=roger*" But when I switch to ldaps using this command line; ldapsearch -d 9 -D cn=admin,dc=mydomain,dc=com -w mypassword \ -b dc=mydomain,dc=com -H "ldaps://mydomain.com" "cn=roger*" This is what I get; ldap_url_parse_ext(ldaps://mydomain.com) ldap_create ldap_url_parse_ext(ldaps://mydomain.com:636/??base) ldap_sasl_bind ldap_send_initial_request ldap_new_connection 1 1 0 ldap_int_open_connection ldap_connect_to_host: TCP mydomain.com:636 ldap_new_socket: 3 ldap_prepare_socket: 3 ldap_connect_to_host: Trying 127.0.0.1:636 ldap_pvt_connect: fd: 3 tm: -1 async: 0 TLS: can't connect: A TLS packet with unexpected length was received.. ldap_err2string ldap_sasl_bind(SIMPLE): Can't contact LDAP server (-1) Now if I check netstat -al I can see; tcp 0 0 *:www *:* LISTEN tcp 0 0 *:ssh *:* LISTEN tcp 0 0 *:https *:* LISTEN tcp 0 0 *:ldaps *:* LISTEN tcp 0 0 *:ldap *:* LISTEN I'm not sure if this is significant as well ... I suspect it is; openssl s_client -connect mydomain.com:636 -showcerts CONNECTED(00000003) 916:error:140790E5:SSL routines:SSL23_WRITE:ssl handshake failure:s23_lib.c:188: I think I've made all my certificates etc OK and here are the results of some checks; If I do this; certtool -e --infile /etc/ssl/certs/ldap_cacert.pem I get Chain verification output: Verified. certtool -e --infile /etc/ssl/certs/mydomain.com_slapd_cert.pem Gives "certtool: the last certificate is not self signed" but it otherwise seems OK? Where have I gone wrong? Surely getting openldap to run securely on ubuntu should be easy and not require a degree in rocket science! Any ideas?

    Read the article

  • 2 Servers setup for redundency, backup

    - by minal
    I presently have 1 dedicated virtual server running my website/blog/mail, etc. This is on Hyper-V with 512MB RAM. Windows Web2008. With the VM, I have these running within it: SmarterMail – for emails MS DNS – I have my own nameservers on this server SQL Express IIS7 2 IP Address I have now leased 2 physical servers : P4 2.6Ghz 1GB RAM 80GB HDD. With these new servers, I get 2 IPs per server as well. These are running Windows 2008 Standard. With the VM the HDD was obviously on a RAID setup so I was not worried about hardware issues as it fell on the provider to manage. However, with the new servers the HDD is not RAID’d, hence my concern is that if it fails I need a backup position. What would be the most ideal setup to go for? I am thinking: Server 1: (Web/PrimaryDNS) DNS – NS1 SQL Express – OFF turn on when required, ie. Server2 is down SmarterMail – OFF turn on when required, ie. Server2 is down IIS 7 Server2:(SQL/Backup) DNS – NS2 SQL Web Edition SmarterMail IIS 7 How can I set it up so that if 1 goes down I can have everything on 2 instantly or by manual switching over. I am confused as other DNS servers will cache the web servers IP address for requests, and if that server goes down, the backup server will have a different IP. How do I make this work? I will be doing routine backups, in which case I will keep copies of backups on both servers. If I am copying the same stuff on both servers like a mirror then I am losing on using the true performance out of it. It's like 1 server is always on standby. Ideally I want SQL and web on 2 diff machines for best performance. If Server1 goes down, I should be able to switch to Server2 fairly easily. I don't have a problem with manual intervention to start the sql/mail services, etc. In terms of scalabilty, the VM has coped pretty well to date. Moving forward the SQL and IIS workload is going to double pretty quickly. Some ideas would be great.

    Read the article

  • Xubuntu login hangs after Cancel Button click

    - by akester
    I'm running Xubuntu 12.04 (I installed using the alternative installer.) running in Virtaulbox 4.1.20 My issue is with the login screen (lightdm-gtk-greeter). It usually runs just fine, and allows users to log in and out but it will hang if the user presses the cancel button. The interface is still working (ie, shutdown menu is still available, I can switch to a different tty) but the username or password field (depending on when the button is hit) is disabled. Restarting lightdm will reset the screen, but the problem still exists. The issue is only with the cancel button. The login, session, and language buttons/menus as well as the accessibility and shutdown menu appear to work normally. I've modified some of the config files for lighdm-gtk-greeter, specifically /etc/lightdm/lighdm-gtk-greeter.conf to change the background image and /etc/lightdm/lightdm.conf to disable the user list. I did not check to see if the error existed before the changes took place. The changes have been restored the default settings but the problem persists. Here is the output of /var/log/lightdm/lightdm.log when the screen is hung: [+0.00s] DEBUG: Logging to /var/log/lightdm/lightdm.log [+0.00s] DEBUG: Starting Light Display Manager 1.2.1, UID=0 PID=2072 [+0.00s] DEBUG: Loaded configuration from /etc/lightdm/lightdm.conf [+0.00s] DEBUG: Using D-Bus name org.freedesktop.DisplayManager [+0.00s] DEBUG: Registered seat module xlocal [+0.00s] DEBUG: Registered seat module xremote [+0.00s] DEBUG: Adding default seat [+0.00s] DEBUG: Starting seat [+0.00s] DEBUG: Starting new display for greeter [+0.00s] DEBUG: Starting local X display [+0.02s] DEBUG: Using VT 7 [+0.02s] DEBUG: Activating VT 7 [+0.03s] DEBUG: Logging to /var/log/lightdm/x-0.log [+0.04s] DEBUG: Writing X server authority to /var/run/lightdm/root/:0 [+0.04s] DEBUG: Launching X Server [+0.05s] DEBUG: Launching process 2078: /usr/bin/X :0 -auth /var/run/lightdm/root/:0 -nolisten tcp vt7 -novtswitch [+0.05s] DEBUG: Waiting for ready signal from X server :0 [+0.05s] DEBUG: Acquired bus name org.freedesktop.DisplayManager [+0.05s] DEBUG: Registering seat with bus path /org/freedesktop/DisplayManager/Seat0 [+0.28s] DEBUG: Got signal 10 from process 2078 [+0.28s] DEBUG: Got signal from X server :0 [+0.28s] DEBUG: Connecting to XServer :0 [+0.29s] DEBUG: Starting greeter [+0.29s] DEBUG: Started session 2082 with service 'lightdm', username 'lightdm' [+0.36s] DEBUG: Session 2082 authentication complete with return value 0: Success [+0.36s] DEBUG: Greeter authorized [+0.36s] DEBUG: Logging to /var/log/lightdm/x-0-greeter.log [+0.36s] DEBUG: Session 2082 running command /usr/lib/lightdm/lightdm-greeter-session /usr/sbin/lightdm-gtk-greeter [+0.58s] DEBUG: Greeter connected version=1.2.1 [+0.58s] DEBUG: Greeter connected, display is ready [+0.58s] DEBUG: New display ready, switching to it [+0.58s] DEBUG: Activating VT 7 [+1.04s] DEBUG: Greeter start authentication for andrew [+1.04s] DEBUG: Started session 2137 with service 'lightdm', username 'andrew' [+1.09s] DEBUG: Session 2137 got 1 message(s) from PAM [+1.09s] DEBUG: Prompt greeter with 1 message(s) [+17.24s] DEBUG: Cancel authentication [+17.24s] DEBUG: Session 2137: Sending SIGTERM

    Read the article

  • VPN - force a selective range of ip to run on VPN (linux)

    - by Francesco
    Preface: I know there are similar question here and there however I'm a kind of newbie on Net stuff so I need an answer on this specific scenario, hoping that can help others too as it is a common problem Let say I cannot do anything on the local switch to change the local ip range, I don't want to use any complicate trick as use VMachine to hide the local ip range but I want to use net tools to solve the issue. Scenario my local net assign me an IP of this class 192.168.1.xxx (ex. 192.168.1.116) and my VPN (VPNC) assign me IP of same class 192.168.1.xxx (ex. 192.168.1.247) Obviously I need VPN to access local address (ex. 192.168.1.100) but when I open any address of the class 192.168.1.xx the route point to my local net and not to the VPN ones. I'm on linux and i'd like gui solution (network manager) in case it is not possible let play with route command. here what network manager offer me: Here my actual route once connected to the VPN: Here some route information (route -n) Destination Gateway Genmask Flags Metric Ref Use Iface 0.0.0.0 0.0.0.0 0.0.0.0 U 0 0 0 ppp0 169.254.0.0 0.0.0.0 255.255.0.0 U 1000 0 0 wlan0 182.71.21.106 192.168.1.1 255.255.255.255 UGH 0 0 0 wlan0 182.71.21.106 192.168.1.1 255.255.255.255 UGH 0 0 0 wlan0 192.168.1.0 0.0.0.0 255.255.255.0 U 9 0 0 wlan0 192.168.1.246 0.0.0.0 255.255.255.255 UH 0 0 0 ppp0 Here my ifconfig : ppp0 Link encap:Point-to-Point Protocol inet addr:192.168.1.247 P-t-P:192.168.1.246 Mask:255.255.255.255 UP POINTOPOINT RUNNING NOARP MULTICAST MTU:1400 Metric:1 RX packets:3415 errors:0 dropped:0 overruns:0 frame:0 TX packets:2525 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:3 RX bytes:3682328 (3.6 MB) TX bytes:402315 (402.3 KB) wlan0 Link encap:Ethernet HWaddr 4c:eb:42:06:a3:a6 inet addr:192.168.1.116 Bcast:192.168.1.255 Mask:255.255.255.0 inet6 addr: fe80::4eeb:42ff:fe06:a3a6/64 Scope:Link UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1 RX packets:72598 errors:0 dropped:0 overruns:0 frame:0 TX packets:42300 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:1000 RX bytes:76000532 (76.0 MB) TX bytes:13919400 (13.9 MB) The Question So basically I would like to add a rule to force this particular address (192.168.1.100) on the VPN and not on my local net

    Read the article

  • What are some of the best wireless routers for a price-conscious home power-user?

    - by Alain
    I'm extremely dissatisfied with the 'popular' choice for routers in homes and small offices. They are expensive (upwards of 60$), lack a great deal of useful configuration options, and seem to need to be restarted quite often. (Linksys comes to mind). I've been on the market for a good router lately, and slowly collecting a set of requirements I feel good routers should meet. Maximum number of TCP/IP connections. - This isn't something I see any routers advertise, but in terms of supporting torrent applications, I've been screwed by routers that support less than 20 here. From what I understand a fairly standard number is 200, but there are not so expensive routers that support thousands. Router configuration menu - Most have standard menu's that let you set up basic things like your wireless network encryption settings, uPnP, and maybe even DMZ (demilitarized zones). An absolute requirement for me, however, are routers with good enough firmware to support: Explicit Port forwarding Assigning static local ips to specific mac addresses, or at least Port forwarding by MAC address Port, IP and MAC filtering Dynamic DNS service for home users who want to set up a server but have a dynamic IP Traffic shaping (ideally) - giving priority to packets from certain machines or over certain ports. Strong wireless signal - If getting a reliable signal requires me to be so close to the router that I can connect an Ethernet cable, it's not good enough. As many Ethernet ports as possible. - Because I want to be able to switch from console gaming to PC gaming without visiting my router. So far, the best thing I've stumbled upon (in the bargain bin at staples) was a 20$ retail plus router. It was meant to be the cheapest alternative until I could find something better to purchase online, but I was actually blown away by the firmware capabilities. It supports defining reserved bandwidth for certain network traffic, dynamic DNS, reserving local IPs for specific MAC addresses, etc. At 2 am when my roommate is killing our Internet with their torrents, I can limit their bandwidth without outright blacklisting them. I have, however, met serious limitations when it comes to network traffic between local machines. It claims a 300Mbps connection, but I have trouble streaming videos from my PC to my console or other laptops wirelessly. It has a meltdown and needs to be reset once in a while (no more than a couple times a month), and it's got a 200 connection limit. There 4 Ethernet ports in the back but I'm pretty sure the first doesn't work. So some great answers to this question would be: Any metrics you use to compare routers, and requirements you have for new candidates. The best routers you've found for supporting home servers, file management systems, high volume torrent traffic, good price/feature ratio, etc. Good configuration advice (aside from 'use Ethernet whenever possible') Thanks for your feedback and experiences!

    Read the article

  • What "pieces" are needed in order to set up a cluster of physical servers?

    - by Chris Dutrow
    Background: Currently, we use Rackspace cloud servers. We have no intention to stop using them, but would like to look into setting up a cluster of physical servers (probably desktop computers in the $400 range with 8gb memory each) to offset some of our load and work as a secondary, more powerful, less reliable system. To put things in perspective, we can buy comparable desktop computers for the same price as we pay in one month to rent them on Rackspace Cloud. I understand that this is generally a dumb idea. However, in this particular instance, the server cluster is needed for its computation power. It is not mission-critical, it does not host a consumer-facing website, and if it goes down for a day or two, its not really a problem. Currently, we have access to business class verizon fios. If I understand correctly, we can get at least 25 dedicated IP addresses with this service, this should be enough. Requirements: Each server runs Linux Centos 6.3 Some of the servers run Python and execute processes from a task queue (Redis or RabbitMQ) Some of the servers are capable of serving static files and Python driven REST APIs Some of the servers host a Cassandra database cluster One or more of the servers are a Redis database servers One or more of the servers are PostgreSQL servers Questions: What kind of router or switch is needed? We would like the computers to be able to communicate effectively with each other via internal IP addresses. This is especially important for communicating with servers hosting Redis that need to be able to respond to requests very quickly. Are there special switches or routers that need to be used to connect the servers together? Are Desktop computers ok for this? We have found that we are mostly RAM-bottle necked, I understand that some servers have highly superior CPUs, but I'm not sure we need CPU power as much as we need RAM, which is cheap in Desktop computers. Will we have problems with the WIFI cards in the desktops or any other unexpected hardware limitation? What tools should be used to "image" the servers. For example, when we get an installation right for a Redis server or Cassandra node, are there tools that come with Linux Centos 6.3 to image the server to a USB drive or something like that? Or do we need to use some other software for this? What other things are we missing that we should be concerned about? Thanks so much!

    Read the article

  • IIS URL Rewrite - Redirect any HTTPS traffic to sub-domain

    - by uniquelau
    We have an interesting hosting environment that dictates all secure traffic must travel over a specific sub domain. E.g. http://secure.domain.com/my-page I'd like to handle this switch using URL Rewrite, i.e. at server level, rather than application level. My cases are: https://secure.domain.com/page = NO CHANGE, remains the same https://domain.com/page = sub-domain inserted, https://secure.domain.com/page https://www.domain.com/page = remove 'www', insert sub-domain In my mind the logic is: INPUT = Full Url = http://www.domain.com/page If INPUT contains HTTPS Then check Full URL, does it contain 'secure'? If YES do nothing, if no add 'secure' If INPUT contains 'www' remove 'www' The certificate is not a wild card (e.g. top level domain) and is issues to: https://secure.domain.com/ The website could also be hosted in a staging environment. E.g. https://secure.environment.domain.com/ I do not have control over 'environment' or 'domain' or the 'tld'. Laurence - Update 1, 19th August So as mentioned below, the trick here is to avoid a redirect loop that could drive anyone well loopy. This is what I propose: One rule to force certain traffic to the secure domain: <rule name="Force 'Umbraco' to secure" stopProcessing="true"> <conditions logicalGrouping="MatchAll"> <add input="{REQUEST_URI}" pattern="^/umbraco/(.+)$" ignoreCase="true" /> <add input="{HTTP_HOST}" negate="true" pattern="^secure\.(.+)$" /> </conditions> <action type="Redirect" url="https://secure.{HTTP_HOST}/{R:0}" redirectType="Permanent" /> </rule> Another rule, that then removes the secure domain, expect for traffic on the secure domain. <rule name="Remove secure, expect for Umbraco" stopProcessing="true"> <match url="(.*)" ignoreCase="true" /> <conditions logicalGrouping="MatchAll"> <add input="{HTTP_HOST}" pattern="^secure\.(.+)$" /> <add input="{REQUEST_URI}" negate="true" pattern="^/umbraco/(.+)$" ignoreCase="true" /> </conditions> <!-- Set Domain to match environment --> <action type="Redirect" url="http://staging.domain.com/{R:0}" appendQueryString="true" redirectType="Permanent" /> </rule> This works for a single directory or group of files, however I've been unable to add additional logic into those two rules. For example you might have 3 folders that need to be secure, I tried adding these as Negate records, but then no redirection happens at all. Hmmm! L

    Read the article