Search Results

Search found 8190 results on 328 pages for 'switch'.

Page 285/328 | < Previous Page | 281 282 283 284 285 286 287 288 289 290 291 292  | Next Page >

  • Ubuntu 10.04 LTS - Dual monitor works only sometimes (ATI multi-desktop)

    - by Beres Botond
    I've been using my laptop with an external LCD monitor attached to it at work (Philips 201E). And at home with a different external monitor (Samsung 2032BW). I have an ATI graphics card (HD3450), with Ati Catalyst drivers enabled and I'm using the Single display desktop (Multi-Desktop) seeting. At work I have the external monitor on the left and laptop on the right, while at home the other way around. So when I switch between the two setups, I just needed to go to Ati Catalyst Control Center, change the order of the displays, change the resolution (Home - 1680x1050, Work - 1440x900), reboot and it was all fine. But since a while it doesn't work properly anymore: At home it still works fine. At work it doesn't work. Sometimes it works for some reason, after a few resolution/setting changes in ACCC and reboots... it's very strange and annoying. With the home monitor I can see the whole bootup process on both monitors (laptop + LCD) and it always just works fine. With the work monitor on the external LCD monitor I just see "No video input" until I get to the login screen, then it shows up there as well. But after login it will either: Flicker a few times, but then work OK. Or (more often) Flicker once and then go back to "No video input" again. I usually end up rebooting a few times until it works. Does anyone have any idea for fixing it? This is my xorg.conf currently: Section "ServerLayout" Identifier "amdcccle Layout" Screen 0 "amdcccle-Screen[6]-0" 0 0 Screen "amdcccle-Screen[6]-1" 1280 0 EndSection Section "Files" EndSection Section "Module" Load "glx" EndSection Section "ServerFlags" Option "Xinerama" "off" EndSection Section "Monitor" Identifier "0-LVDS" Option "VendorName" "ATI Proprietary Driver" Option "ModelName" "Generic Autodetecting Monitor" Option "DPMS" "true" Option "PreferredMode" "1280x768" Option "TargetRefresh" "60" Option "Position" "0 0" Option "Rotate" "normal" Option "Disable" "false" EndSection Section "Monitor" Identifier "0-CRT1" Option "VendorName" "ATI Proprietary Driver" Option "ModelName" "Generic Autodetecting Monitor" Option "DPMS" "true" Option "TargetRefresh" "60" Option "Position" "0 0" Option "Rotate" "normal" Option "Disable" "false" Option "PreferredMode" "1440x900" EndSection Section "Device" Identifier "Default Device" Driver "fglrx" EndSection Section "Device" Identifier "amdcccle-Device[6]-0" Driver "fglrx" Option "Monitor-LVDS" "0-LVDS" BusID "PCI:6:0:0" EndSection Section "Device" Identifier "amdcccle-Device[6]-1" Driver "fglrx" Option "Monitor-CRT1" "0-CRT1" BusID "PCI:6:0:0" Screen 1 EndSection Section "Screen" Identifier "Default Screen" DefaultDepth 24 SubSection "Display" Virtual 2560 1024 EndSubSection EndSection Section "Screen" Identifier "amdcccle-Screen[6]-0" Device "amdcccle-Device[6]-0" DefaultDepth 24 SubSection "Display" Viewport 0 0 Depth 24 EndSubSection EndSection Section "Screen" Identifier "amdcccle-Screen[6]-1" Device "amdcccle-Device[6]-1" DefaultDepth 24 SubSection "Display" Viewport 0 0 Depth 24 EndSubSection EndSection

    Read the article

  • Is there a way to permanently arrange 2 displays under XP?

    - by rumtscho
    When I am home or on a business trip, or on a meeting, I use my laptop in the usual way. When I get to work, I put it on the docking station and boot it with the lid closed. The image appears on the two displays connected to the docking station. On the left, there is an old monitor connected over VGA, on the right, a big widescreen connected over DVI. Obviously, the videocard seems to think that the DVI is the primary output, and the VGA the secondary one. Thus Windows always displays the widescreen on the left and the old FSC monitor on the right. So when I want to move the mouse pointer from the (physically) left display to the (physically) right display, I have to move it from right to left, which is a usability nightmare. Of course, I can just drag one display over the other one in the display properties, and then everything is as it should be. The catch: Windows remembers this only as long as it has the two displays. Every time it runs on the laptop display, it forgets the setting. Physically switching the monitors isn't an option, for ergonomical reasons. I prefer to run the more important applications on the bigger screen with the better colourspace, and the shape of my desk forces me to sit off-center, so the more important applications should be shown on the right display. Just switching the video ports doesn't help either. When I connect the big monitor over VGA, image quality deteriorates visibly. So what I do now is: every time I bring the laptop to my desk, I boot it. I wait the whole 7 minutes of XP booting, syncing network drives, etc. Then I fire up the display properties, switch to the last tab, drag the widescreen display to the right, and close. Only then can I start working. Does someone have a better idea? The laptop is a Dell Latitude 630 with Windows XP SP 3. It has an nVidia graphics card (not an onboard chip).

    Read the article

  • broken apache .htaccess (mod_rewrite)

    - by Tim
    Hey there, I'm running into an apache mod_rewrite configuration issue on one of our machines. Has anyone encountered / overcome anyone of these issues. URL1 ( http://www.uppereast.com ) is not being redirected to URL2 ( http://www.nyclocalliving.com ). This definitely worked in my test environment where a localhost address was rewritten to URL2 ( RewriteRule ^http://upe.localhost$ http://www.nyclocalliving.com ). I'm trying to get the all of the redirect rules working ( 2200 + ), but the 'http://www.nyclocalliving.com' site encounters a server error if I use more that 1000 or more rules. A) .htaccess file - I've tried the simplest approach which worked in a local environment 75 # Various rewrite rules. 76 <IfModule mod_rewrite.c> 77 RewriteEngine on 78 79 # BEGIN new URL Mapping rules 80 #RewriteRule ^http://www.uppereast.com/$ http://www.nyclocalliving.com ... 2307 #RewriteRule ^http://www.uppereast.com/zipcodechange.html$ http://www.nyclocalliving.com/zip-code-change fig. 1 B) /var/log/httpd/error_log file - there are these seg. fault errors when I enable the first rule ( line 80 ). no error logs otherwise. 1893 [Fri Sep 25 17:53:46 2009] [notice] Digest: generating secret for digest authentication ... 1894 [Fri Sep 25 17:53:46 2009] [notice] Digest: done 1895 [Fri Sep 25 17:53:46 2009] [notice] Apache/2.2.3 (CentOS) configured -- resuming normal operations 1896 [Fri Sep 25 17:53:47 2009] [notice] child pid 29774 exit signal Segmentation fault (11) 1897 [Fri Sep 25 17:53:47 2009] [notice] child pid 29775 exit signal Segmentation fault (11) 1898 [Fri Sep 25 17:53:47 2009] [notice] child pid 29776 exit signal Segmentation fault (11) 1899 [Fri Sep 25 17:53:47 2009] [notice] child pid 29777 exit signal Segmentation fault (11) 1900 [Fri Sep 25 17:53:47 2009] [notice] child pid 29778 exit signal Segmentation fault (11) 1901 [Fri Sep 25 17:53:47 2009] [notice] child pid 29779 exit signal Segmentation fault (11) fig. 2 C) Some more debug information from the shell; the mod_rewrite is turned on and this is the machine architecture 1 # apachectl -t -D DUMP_MODULES | more 2 Loaded Modules: 3 core_module (static) 4 ... 5 rewrite_module (shared) 1 # uname -a 2 Linux RegionalWeb 2.6.24-23-xen #1 SMP Mon Jan 26 03:09:12 UTC 2009 x86_64 x86_64 x86_64 GNU/Linux fig. 3 I looked into some previous posts (http://serverfault.com/questions/18744/htaccess-not-working-modrewrite), but didn't find a solution for this. I'm sure there's a small switch somewhere that I'm missing. Thanks in advance Tim

    Read the article

  • Puppet - Possible to use software design patterns in modules?

    - by Mike Purcell
    As I work with puppet, I find myself wanting to automate more complex setups, for example vhosts for X number of websites. As my puppet manifests get more complex I find it difficult to apply the DRY (don't repeat yourself) principle. Below is a simplified snippet of what I am after, but doesn't work because puppet throws various errors depending up whether I use classes or defines. I'd like to get some feed back from some seasoned puppetmasters on how they might approach this solution. # site.pp import 'nodes' # nodes.pp node nodes_dev { $service_env = 'dev' } node nodes_prod { $service_env = 'prod' } import 'nodes/dev' import 'nodes/prod' # nodes/dev.pp node 'service1.ownij.lan' inherits nodes_dev { httpd::vhost::package::site { 'foo': } httpd::vhost::package::site { 'bar': } } # modules/vhost/package.pp class httpd::vhost::package { class manage($port) { # More complex stuff goes here like ensuring that conf paths and uris exist # As well as log files, which is I why I want to do the work once and use many notify { $service_env: } notify { $port: } } define site { case $name { 'foo': { class 'httpd::vhost::package::manage': port => 20000 } } 'bar': { class 'httpd::vhost::package::manage': port => 20001 } } } } } That code snippet gives me a Duplicate declaration: Class[Httpd::Vhost::Package::Manage] error, and if I switch the manage class to a define, and attempt to access a global or pass in a variable common to both foo and bar, I get a Duplicate declaration: Notify[dev] error. Any suggestions how I can implement the DRY principle and still get puppet to work? -- UPDATE -- I'm still having a problem trying to ensure that some of my vhosts, which may share a parent directory, are setup correctly. Something like this: node 'service1.ownij.lan' inherits nodes_dev { httpd::vhost::package::site { 'foo_sitea': } httpd::vhost::package::site { 'foo_siteb': } httpd::vhost::package::site { 'bar': } } What I need to happen is that sitea and siteb have the same parent "foo" folder. The problem I am having is when I call a define to ensure the "foo" folder exists. Below is the site define as I have it, hopefully it will make sense what I am trying to accomplish. class httpd::vhost::package { File { owner => root, group => root, mode => 0660 } define site() { $app_parts = split($name, '[_]') $app_primary = $app_parts[0] if ($app_parts[1] == '') { $tpl_path_partial_app = "${app_primary}" $app_sub = '' } else { $tpl_path_partial_app = "${app_primary}/${app_parts[1]}" $app_sub = $app_parts[1] } include httpd::vhost::log::base httpd::vhost::log::app { $name: app_primary => $app_primary, app_sub => $app_sub } } } class httpd::vhost::log { class base { $paths = [ '/tmp', '/tmp/var', '/tmp/var/log', '/tmp/var/log/httpd', "/tmp/var/log/httpd/${service_env}" ] file { $paths: ensure => directory } } define app($app_primary, $app_sub) { $paths = [ "/tmp/var/log/httpd/${service_env}/${app_primary}", "/tmp/var/log/httpd/${service_env}/${app_primary}/${app_sub}" ] file { $paths: ensure => directory } } } The include httpd::vhost::log::base works fine, because it is "included", which means it is only implemented once, even though site is called multiple times. The error I am getting is: Duplicate declaration: File[/tmp/var/log/httpd/dev/foo]. I looked into using exec, but not sure this is the correct route, surely others have had to deal with this before and any insight is appreciated as I have been grappling with this for a few weeks. Thanks.

    Read the article

  • Are file access times not properly maintained in Mac OS X?

    - by Ether
    I'm trying to determine how file access times are maintained by default in Mac OS X, as I'm trying to diagnose some odd behaviour I'm seeing in a new MBP Unibody (running Snow Leopard, 10.6.2): The symptoms (drilling down to the specific behaviour that seems to be causing the issue): mutt is unable to switch to mailboxes which have recently received new mail mail is delivered by procmail, which updates the mtime of the mbox folder it is updating, but does not alter the atime (this is how new mail detection works: by comparing atime to mtime) however, both the mtime and atime of the mbox file is getting updated Through testing, it does not appear that atimes can be set separately in the filesystem: : [ether@tequila ~]$; touch test : [ether@tequila ~]$; touch -m -t 200801010000 test2 : [ether@tequila ~]$; touch -a -t 200801010000 test3 : [ether@tequila ~]$; ls -l test* -rw------- 1 ether staff 0 Dec 30 11:42 test -rw------- 1 ether staff 0 Jan 1 2008 test2 -rw------- 1 ether staff 0 Dec 30 11:43 test3 : [ether@tequila ~]$; ls -lu test* -rw------- 1 ether staff 0 Dec 30 11:42 test -rw------- 1 ether staff 0 Dec 30 11:43 test2 -rw------- 1 ether staff 0 Dec 30 11:43 test3 The test2 file is created with an old mtime, and the atime is set to now (as it is a new file), which is correct. However, test3 is created with an old atime, but is not set properly on the file. To be sure this is not just behaviour seen with new files, let's modify an old file: : [ether@tequila ~]$; touch -a -t 200801010000 test : [ether@tequila ~]$; ls -l test -rw------- 1 ether staff 0 Dec 30 11:42 test : [ether@tequila ~]$; ls -lu test -rw------- 1 ether staff 0 Dec 30 11:45 test So it would seem that atimes cannot be set explicitly (it is always reset to "now" when either mtime or atime modifications are submitted). Is this something inherent to the filesystem itself, is it something that can be changed, or am I totally crazy and looking in the wrong place? PS. the output of mount is: : [ether@tequila ~]$; mount /dev/disk0s2 on / (hfs, local, journaled) devfs on /dev (devfs, local, nobrowse) map -hosts on /net (autofs, nosuid, automounted, nobrowse) map auto_home on /home (autofs, automounted, nobrowse) ...and Disk Utility says that the drive is of type "Mac OS Extended (Journaled)".

    Read the article

  • How can I repair my USB drive?

    - by yurko
    USB drive is in read only state and I can't repair it. First of all I tried erase it using dd: root@yurko-laptop:/home/yurko-laptop# ls -l /dev/disk/by-id | grep usb lrwxrwxrwx 1 root root 9 ??? 18 23:45 usb-Generic_Flash_Disk_C173828A-0:0 -> ../../sdb lrwxrwxrwx 1 root root 10 ??? 18 23:45 usb-Generic_Flash_Disk_C173828A-0:0-part1 -> ../../sdb1 root@yurko-laptop:/home/yurko-laptop# dd if=/dev/zero of=/dev/sdb dd: ?????? ? «/dev/sdb»: ?? ?????????? ????????? ????? 8257537+0 ??????? ??????? 8257536+0 ??????? ???????? ??????????? 4227858432 ????? (4,2 GB), 942,633 c, 4,5 MB/c After that I wanted to create new filesystem using fdisk: root@yurko-laptop:/home/yurko-laptop# fdisk /dev/sdb You will not be able to write the partition table. WARNING: DOS-compatible mode is deprecated. It's strongly recommended to switch off the mode (command 'c') and change display units to sectors (command 'u'). Command (m for help): p Disk /dev/sdb: 4227 MB, 4227858432 bytes 4 heads, 63 sectors/track, 32768 cylinders Units = cylinders of 252 * 512 = 129024 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x00000000 Device Boot Start End Blocks Id System /dev/sdb1 18 32768 4126596 b W95 FAT32 Command (m for help): fdisk showed that the partition still exists and I can't write the partition table. I tried to delete the existing partition: Command (m for help): d Selected partition 1 Command (m for help): w Unable to write /dev/sdb root@yurko-laptop:/home/yurko-laptop# Why am I not be able to write the partition table? Does it mean that some hardware failure occurred? And is it possible to repair the current USB drive? I've tried to use hdparm and it showed that the readonly flag is on: root@yurko-laptop:/home/yurko-laptop# hdparm /dev/sdb /dev/sdb: SG_IO: bad/missing sense data, sb[]: f0 00 05 00 00 00 00 0a 00 00 00 00 26 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 multcount = 0 (off) readonly = 1 (on) readahead = 256 (on) geometry = 1016/131/62, sectors = 8257536, start = 0

    Read the article

  • How to unlock and remove a protected partition from Prestigio USB stick?

    - by mr.b
    Ok, so, I have one of those fancy schmancy devices, which is given to me by a frustrated friend of mine. Device is a Prestigio Leather 8GB, which identifies itself to Linux host as: Bus 001 Device 006: ID 1307:0165 Transcend Information, Inc. 2GB/4GB Flash Drive Kernel messages as USB device is plugged in: kernel: [ 2769.580042] usb 1-9: new high speed USB device using ehci_hcd and address 7 kernel: [ 2769.714782] scsi8 : usb-storage 1-9:1.0 kernel: [ 2770.713937] scsi 8:0:0:0: Direct-Access 8192MB flash drive 1.00 PQ: 0 ANSI: 2 kernel: [ 2770.714535] scsi 8:0:0:1: Direct-Access 8192MB flash drive 1.00 PQ: 0 ANSI: 2 kernel: [ 2770.715734] sd 8:0:0:0: Attached scsi generic sg3 type 0 kernel: [ 2770.716108] sd 8:0:0:1: Attached scsi generic sg4 type 0 kernel: [ 2770.722175] sd 8:0:0:0: [sdc] 962560 512-byte logical blocks: (492 MB/470 MiB) kernel: [ 2770.722657] sd 8:0:0:0: [sdc] Write Protect is on kernel: [ 2770.731078] sd 8:0:0:1: [sdd] 14012416 512-byte logical blocks: (7.17 GB/6.68 GiB) kernel: [ 2770.731215] sdc: kernel: [ 2770.738251] sd 8:0:0:1: [sdd] Write Protect is off kernel: [ 2770.880328] kernel: [ 2770.885876] sd 8:0:0:0: [sdc] Attached SCSI removable disk kernel: [ 2770.887442] sdd: unknown partition table kernel: [ 2771.049605] sd 8:0:0:1: [sdd] Attached SCSI removable disk So, symptoms are typical for U3-like devices: two separate devices inside of a single flash device. Windows sees it also as two identical usb devices, and mounts two separate drives to system, whereas first one presents itself as a CDROM device, holding a write-protected content, and second is a regular flash-disk partition, that "can" be written to. However, it seems like it's broken in some weird way, since it won't let me write anything to it, format it, nothing, but that's not the issue right now. Question: How can I unlock entire USB stick so it appears to system as a single, 8GB device which can be partitioned and used normally, without restrictions? Since it appeared to be an U3 device, I have tried standard utilities: both U3 Uninstaller by u3.com (found on SoftPedia), and opensource u3_tool from sourceforge (on both Windows and Linux). First utility failed to even detect USB stick as U3 device (simply stood idle while I re-plugged stick several times), while second tool failed with some obscure error about SCSI command unable to do something (I might be able to provide exact errors when I switch back to windows). u3_tool -i /dev/sg3 (Display device info) fails with u3_partition_info() failed: Device reported command failed: status 1 ...and every other option fails with same error, minus first part which states which command precisely has failed. So, apparently, this isn't a U3 device. Or, if it is, it doesn't behave like one. I read on a few occasions that this device protection is done by special command sent to device which tells it to lock itself, and so there should be an unlock command, that would set drive straight. Does anyone have any idea about what could I do to this device to fix it? P.S. I also mentioned a problem with being unable to use second "drive", but I'll tackle that problem when (and if) I manage to merge those two devices into one...

    Read the article

  • Perl missing while installing nginx on centos

    - by Ahoura Ghotbi
    I am trying to install nginx on my server, however it keeps returning "./configure: error: perl 5.6.1 or higher is required" eventhough I have perl v5.8.8!!!! I have already downloaded perl and trying to configure it using the following command : ./configure --with-http_stub_status_module --with-http_perl_module --with-http_flv_module --add-module=nginx_mod_h264_streaming here is the output : [root@fst nginx-0.8.55]# ./configure --with-http_stub_status_module --with-http_perl_module --with-http_flv_module --add-module=nginx_mod_h264_streaming checking for OS + Linux 2.6.18-308.el5 x86_64 checking for C compiler ... found + using GNU C compiler + gcc version: 4.1.2 20080704 (Red Hat 4.1.2-52) checking for gcc -pipe switch ... found checking for gcc builtin atomic operations ... found checking for C99 variadic macros ... found checking for gcc variadic macros ... found checking for unistd.h ... found checking for inttypes.h ... found checking for limits.h ... found checking for sys/filio.h ... not found checking for sys/param.h ... found checking for sys/mount.h ... found checking for sys/statvfs.h ... found checking for crypt.h ... found checking for Linux specific features checking for epoll ... found checking for sendfile() ... found checking for sendfile64() ... found checking for sys/prctl.h ... found checking for prctl(PR_SET_DUMPABLE) ... found checking for sched_setaffinity() ... found checking for crypt_r() ... found checking for sys/vfs.h ... found checking for nobody group ... found checking for poll() ... found checking for /dev/poll ... not found checking for kqueue ... not found checking for crypt() ... not found checking for crypt() in libcrypt ... found checking for F_READAHEAD ... not found checking for posix_fadvise() ... found checking for O_DIRECT ... found checking for F_NOCACHE ... not found checking for directio() ... not found checking for statfs() ... found checking for statvfs() ... found checking for dlopen() ... not found checking for dlopen() in libdl ... found checking for sched_yield() ... found checking for SO_SETFIB ... not found configuring additional modules adding module in nginx_mod_h264_streaming + ngx_http_h264_streaming_module was configured checking for PCRE library ... found checking for system md library ... not found checking for system md5 library ... not found checking for OpenSSL md5 crypto library ... found checking for zlib library ... found checking for perl + perl version: v5.8.8 built for x86_64-linux-thread-multi ./configure: error: perl 5.6.1 or higher is required

    Read the article

  • Blank displays after inactivity, mouse cursor not showing up

    - by Mike Christiansen
    I have a Windows 7 Enterprise x86 machine that is exhibiting some strange problems. After some inactivity (it varies how long it takes), when I come back to my computer, both of my monitors are black. The monitors are on, with a black display. Moving the mouse and pressing keys on the keyboard do not work. This happens at least once a day. When I first encountered the issue, I performed a hard shutdown and restarted the computer. About 10% of the time when I did this, the resolutions on my monitors were messed up. The native resolution on the primary monitor is 1600x900, and the native on my secondary is 1440x900. None of the widescreen resolutions would be present in the display properties. I had 800x600, 1024x768, and 1280x1024. As a workaround to this issue, I've found that if I plug in my secondary monitor as the primary monitor, and leave the secondary unplugged, then Windows will start in 1024x768 on the secondary. Then, I can use Windows 7's "Detect" feature and it finds the 1440x900 resolution, and sets it. Then I have to connect the primary monitor to the secondary port and set it as the primary. Then I can switch the two cables, putting the primary into the primary, the secondary into the secondary. Then use the "Detect" feature again, and it finds the correct resolutions. Some time after performing the above, I discovered that when the screens were blanked, I could simply press "Control+Alt+Delete", type in my password, and everything comes up fine - except my mouse cursor. All applications and features work as intended, except there is no mouse cursor (the mouse actually works though...). I have the "Show location of pointer when I press CTRL key" option selected, so I can press CTRL and use my mouse as normal - but I have no actual cursor. When the computer is in this state, UAC is also not functional. Whenever a UAC prompt appears, the screens go black (the original symptoms) and I have to press Escape to exit UAC. Because of the above symptoms (the UAC black screen thing, etc) I beleive winlogon.exe may be the culprit. However, I have no idea how to fix it. I am unable to restart winlogon.exe due to the problems I am having with winlogon.exe (the UAC black screen) Looking for any ideas.... More information Windows 7 x86 Enterprise Domain environment (I have a secondary account with administrator rights) Dell Optiplex 960 Cannot perform "optional" windows updates due to an activation issue (I am testing a windows 7 image, and an activation infrastructure has not been created yet. However, this issue was happening before I was unable to perform windows update, and windows was up to date at the time Updated video card driver (as an attempt to fixing the resolution issue) Disabled all power saving options Please let me know what else you need to help me solve this issue! Thanks in advance, Mike

    Read the article

  • How can I force a merge of all WAL files in pg_xlog back into my base "data" directory?

    - by Zac B
    Question: Is there a way to tell Postgres (9.2) to "merge all WAL files in pg_xlog back into the non-WAL data files, and then delete all WAL files successfully merged?" I would like to be able to "force" this operation; i.e. checkpoint_segments or archiving settings should be ignored. The filesystem WAL buffer (pg_xlog) directory should be emptied, or nearly emptied. It's fine if some or all of the space consumed by the pg_xlog directory is then consumed by the data directory; our DBA has asked for WAL database backups without any backlogged WALs, but space consumption is not a concern. Having near-zero WAL activity during this operation is a fine constraint. I can ensure that the database server is either shut down or not connectible (zero user-generated transaction load) during this process. Essentially, I'd like Postgres to ignore archiving/checkpoint retention policies temporarily, and flush all WAL activity to the core database files, leaving pg_xlog in the same state as if the database were recently created--with very few WAL files. What I've Tried: I know that the pg_basebackup utility performs something like this (it generates an almost-all-WALs-merged copy of a Postgres instance's data directory), but we aren't ready to use it on all our systems yet, as we are still testing replication settings; I'm hoping for a more short-term solution. I've tried issuing CHECKPOINT commands, but they just recycle one WAL file and replace it with another (that is, if they do anything at all; if I issue them during database idle time, they do nothing). pg_switch_xlog() similarly just forces a switch to the next log segment; it doesn't flush all queued/buffered segments. I've also played with the pg_resetxlog utility. That utility sort of does what I want, but all of its usage docs seem to indicate that it destroys (rather than flushing out of the transaction log and into the main data files) some or all of the WAL data. Is that impression accurate? If not, can I use pg_resetxlog during a zero-WAL-activity period to force a flush of all queued WAL data to non-WAL data? If the answer to that is negative, how can I achieve this goal? Thanks!

    Read the article

  • Understanding packet flows over RVI

    - by choco-loo
    I'm trying to get a full grasp of firewall filters and how to apply them on a Juniper EX4200 switch - to be able to block ports, police traffic and shape traffic. The network architecture is as follows internet >-< vlan4000 >-< vlan43 vlan4000 is a public "routed" block (where all the IPs are routed to and the internet gw is) vlan43 is a vlan with public IPs with devices (servers) attached There are static routes and RVI's on the EX4200 to send all traffic via vlan4000's gateway to reach the internet. I've set up filters on both input and output of the respective RVI's and VLAN's - with simple counters, to measure traffic flow from a server inside of vlan43 and a server on the internet. Using a combination of iperf for UDP and TCP tests and fping for ICMP tests - I observed the following, icmp vlan43>internet internet>vlan43 unit4000-counter-in 0 0 unit4000-counter-out 0 0 unit43-counter-in 100 100 unit43-counter-out 0 0 vlan4000-counter-in 6 4 vlan4000-counter-out 107 104 vlan43-counter-in 101 100 vlan43-counter-out 100 100 tcp vlan43>internet internet>vlan43 unit4000-counter-in 0 0 unit4000-counter-out 0 0 unit43-counter-in 73535 38480 unit43-counter-out 0 0 vlan4000-counter-in 7 8 vlan4000-counter-out 73543 38489 vlan43-counter-in 73535 38481 vlan43-counter-out 38938 75880 udp vlan43>internet internet>vlan43 unit4000-counter-in 0 0 unit4000-counter-out 0 0 unit43-counter-in 81410 1 unit43-counter-out 0 0 vlan4000-counter-in 18 7 vlan4000-counter-out 81429 8 vlan43-counter-in 81411 1 vlan43-counter-out 1 85472 My key goals are to set up a few filters and policers, as there will be many more VLANs - that all need protecting from each other and the internet. Then globally limit/police all outbound traffic to the internet Block inbound ports to vlan43 (eg. 22) Limit outbound traffic from vlan43 (to the internet) Limit outbound traffic from vlan43 (to other vlans) Limit outbound traffic from vlan4000 (to the internet from all vlans) Route traffic from vlans via specific routing instances (FBF) The question What I want to understand is why there isn't ever any activity on unit4000 or vlan4000 inbound or outbound counter - is this because there isn't a device on this VLAN - and that the traffic is only traversing it? And with regards to the TCP test - why is there twice as many packets on unit43-counter-in, vlan4000-counter-out and vlan43-counter-in - is this counting both the inbound and outbound traffic?

    Read the article

  • How to configure Transparent IP Address Sharing (TAS) on a Mediatrix 4102 with DGW 2.0 firmware?

    - by Pascal Bourque
    I am making the switch to VoIP. I chose voip.ms as my service provider and Mediatrix 4102 as my ATA. One reason why I chose the Mediatrix over other popular consumer ATAs is that it's supposed to be easy to place it in front of the router, so it can give priority to its own upstream traffic over the home network's upstream traffic. This is supposed to work transparently, with the ATA and router sharing the same public IP address (the one obtained from the modem). They call this feaure Transparent IP Address Sharing, or TAS. Their promotional brochure describes it like this: The Mediatrix 4102 also uses its innovative TAS (Transparent IP Address Sharing) technology and an embedded PPPoE client to allow the PC (or router) connected to the second Ethernet port to have the same public IP address, eliminating the need for private IP addresses or address translations. I am interested by this feature because my router, an Apple Time Capsule, doesn't support QoS and cannot give priority to the voice packets if the ATA is behind the router. However, after hours of searching the web, reading the documentation, and good ol' trial and error, I haven't been able to configure the Mediatrix to run in this mode. Then I found a version of the manual that looks like it was for a previous version of the firmware (SIP), where there is an entire section dedicated to configuring TAS (starting at page 209). But my Mediatrix comes with the DGW 2.0 firmware, whose documentation does not mention TAS at all. So I tried to follow the TAS setup instructions from the SIP documentation and apply them to my DGW firmware, using the Variable Mapping Between SIP v5.0 and DGW v2.0 document as a reference, but no success. Some required SIP variables don't have an equivalent in DGW. So it looks like the DGW firmware does not support TAS at all, or if it does they are not doing anything to help us set it up. So right now, the Mediatrix is behind the router and VoIP works perfectly except when my upstream bandwidth is saturated. My questions are: Is downgrading to SIP firmware the only way to have my Mediatrix 4102 run in TAS mode? If not, anybody knows how to setup TAS on the DGW firmware? Is TAS mode the only way to give priority to the voice packets if I want to keep my current router (Apple Time Capsule)? Thanks!

    Read the article

  • Wake On Lan only works on first boot, not sequent ones

    - by sp3ctum
    I have converted my old Dell Latitude D410 laptop to a server for tinkering. It is running an updated Debian Squeeze (6) with a Xen enabled kernel (I want to toy with virtual machines later on). I am running it 'headless' via an ethernet connection. I am struggling to enable Wake On Lan for the box. I have enabled the setting in the BIOS, and it works nicely, but only for the first time after the power cord is plugged in. Here is my test: Plug in power cord, don't boot yet Send magic Wake On Lan packet from test machine (Ubuntu) using the wakeonlan program Server expected to start (does every time) Once server has booted, log in via ssh and shut it down via the operating system After shutdown, wake server up via WOL again (fails every time) Some observations: Right after step 1 I can see the integrated NIC has a light on. I deduce this means the NIC gets adequate power and that the ethernet cable is connected to my switch. This light is not on after step 4 (the shutdown stage). The light becomes back on after I disconnect and reconnect the power cord, after which WOL works as well. After step 4 I can verify that wake on lan is enabled via the ethtool program (repeatable each time) This blog post suggested the problem may lay in the fact the motherboard might not be giving adequate power to the NIC after shutdown, so I copied an acpitool script that supposedly should signal the system to give the needed power to the card when shut down. Obviously it did not fix my issue. I have included the relevant power settings in the paste below. I have tried different combinations of parameters of shutdown (the program) options, as well as the poweroff program. I even tried "telinit 0", which I figured would do the most direct boot via software. If I keep the laptop's power button pressed down and do a hard boot this way, the light on the ethernet port stays lit and a WOL is possible. I copied a bunch of hopefully useful information in this paste I have tried this with the laptop battery connected and without it. I get the same result. Promptly pressing the power button causes the system to shut down with the message "The system is going down for system halt NOW!", and WOL is still unsuccessful.

    Read the article

  • APC ups es 700 randomly overload

    - by Matteo Mosca
    First of all, I live in Italy, Europe, so keep this in mind for Volt/Watt considerations. Standard voltage in Italian apartments is 220V. In my living room I have 2 APC ups, one being an ES-550 and the other an ES-700 They each have 4 slots for surge protection only, and 4 slots for surge protection + battery backup. Just to give all the information, they both got their battery replaced less than one month ago. The ES-550 works fine, without any problem. On the battery I have connected: Pc Monitor Sony Bravia 46'' 4th slot is empty The ES-700 has the following on battery: Xbox 360 Ps3 (standby when not used) Wii (standby when not used) Netgear 8 port switch (always on) Here's what happens: the ES-700, randomly, but mostly at night when I'm sleeping, goes like "overload", with the constant beep. If I try to shut it off keeping the power button pressed, nothing happens. The only thing that works is unplugging random stuff (sometimes unplugging 1 console works, other times I have to unplug all 4 devices). Every time this happens the problem is "real", meaning the 4 devices become unpowered, so it's not just an "alarm no working properly" problem. While I'm sleeping, of course, the power usage is what described on the list, 2 devices on standy, 1 off and 1 on. Today it happened again while I was playing with my Ps3. I unplugged it, problem went away. I plugged it again, and it kept working fine. I just can't figure out what's the problem. The only additional info I can provide is that this behaviour started after a big power outage last december 26 (a blackout that lasted almost all day) but the "surge protection" part of those UPS should be there for those problems, to leverage peaks when power goes away or gets restored. Another funny thing is, althought it might not be related, for a couple of days after that event the Wii was unable to power on, I thought its power transformer was broken, but then it suddenly started working again. I can be sure it's not the Wii overloading the UPS because the overload happens even if I leave the Wii unplugged. Any suggestion is really appreciated, and I can provide any additional info, if needed, that didn't come to mind right now. Thanks.

    Read the article

  • 64-bit linux kernel only seeing 3 of 4GB after upgrade...

    - by Blaine
    Hey everyone. I am running Ubuntu 9.04 64-bit on my macbook. I had 2GB of ram before, and everything ran great. I just upgraded to 2x2GB (4GB), but my system only sees 3GB of it. OS X, which I am dual booting, sees all 4GB. Also, my video performance is incredibly lacking. Before the upgrade my compiz benchmark was full at 80fps, and now it is at 22fps with very choppy window dragging. Has anyone ever heard of this on a 64-bit kernel? I just don't quite understand what could be the issue. 10$ uname -a Linux macbook 2.6.28-15-generic #49-Ubuntu SMP Tue Aug 18 19:25:34 UTC 2009 x86_64 GNU/Linux $ free -m total used free shared buffers cached Mem: 2953 1031 1921 0 114 427 -/+ buffers/cache: 489 2463 Swap: 7812 0 7812 9$ lsmod Module Size Used by i915 77960 2 drm 123232 3 i915 binfmt_misc 18572 1 ppdev 16904 0 btusb 21784 2 bridge 63776 0 stp 11140 1 bridge bnep 22912 2 vboxnetadp 109356 0 vboxnetflt 116972 0 vboxdrv 1721612 1 vboxnetflt uvcvideo 69640 0 compat_ioctl32 18304 1 uvcvideo videodev 45184 2 uvcvideo,compat_ioctl32 v4l1_compat 23940 2 uvcvideo,videodev lp 19588 0 parport 49584 2 ppdev,lp snd_hda_intel 557492 3 snd_pcm_oss 52352 0 snd_mixer_oss 24960 1 snd_pcm_oss snd_pcm 99464 2 snd_hda_intel,snd_pcm_oss arc4 10240 2 snd_seq_dummy 11524 0 ecb 11392 2 snd_seq_oss 41984 0 snd_seq_midi 15744 0 snd_rawmidi 33920 1 snd_seq_midi snd_seq_midi_event 16512 2 snd_seq_oss,snd_seq_midi snd_seq 66272 6 snd_seq_dummy,snd_seq_oss,snd_seq_midi,snd_seq_midi_event ath9k 310584 0 snd_timer 34064 2 snd_pcm,snd_seq snd_seq_device 16276 5 snd_seq_dummy,snd_seq_oss,snd_seq_midi,snd_rawmidi,snd_seq mac80211 251528 1 ath9k iTCO_wdt 21712 0 iTCO_vendor_support 12420 1 iTCO_wdt joydev 20992 0 video 29204 0 snd 78920 15 snd_hda_intel,snd_pcm_oss,snd_mixer_oss,snd_pcm,snd_seq_oss,snd_rawmidi,snd_seq,snd_timer,snd_seq_device applesmc 37700 0 output 11648 1 video soundcore 16800 1 snd pcspkr 11136 0 cfg80211 43680 1 mac80211 appletouch 19972 0 isight_firmware 11520 0 input_polldev 12688 1 applesmc intel_agp 39408 1 snd_page_alloc 18704 2 snd_hda_intel,snd_pcm led_class 13064 2 ath9k,applesmc hid_apple 15872 0 usbhid 47040 0 ohci1394 42164 0 ieee1394 108288 1 ohci1394 sky2 63364 0 fbcon 49792 0 tileblit 11264 1 fbcon font 17024 1 fbcon bitblit 14464 1 fbcon softcursor 10368 1 bitblit Some information from dmesg: [ 795.820163] ACPI: EC: GPE storm detected, transactions will use polling mode [ 1762.709516] [drm:i915_getparam] *ERROR* Unknown parameter 6 [ 1763.078130] [drm:i915_getparam] *ERROR* Unknown parameter 6 [ 2362.760889] [drm:i915_getparam] *ERROR* Unknown parameter 6 [ 2416.352084] ACPI: EC: missing confirmations, switch off interrupt mode. [ 3718.721095] [drm:i915_getparam] *ERROR* Unknown parameter 6 [ 3719.108914] [drm:i915_getparam] *ERROR* Unknown parameter 6 [ 4318.773266] [drm:i915_getparam] *ERROR* Unknown parameter 6 [ 9513.813066] CE: hpet increasing min_delta_ns to 15000 nsec [ 9693.815684] npviewer.bin[6736]

    Read the article

  • Apache works on http and https, SVN only on http

    - by user27880
    I asked a question about this before, and got most of it fixed. If I switch off https redirect and go to http://mydomain.com/svn/test0, I get the authentication window popping up, and I can enter my AD credentials, and bingo. Switching https redirect back on, if I go to http://mydomain.com I am automatically redirected to https, which is what I want, and the 'CerntOS test page' pops up. Perfect. The problem occurs when I want to go to one of my test repos via https. Here is my httpd.conf file, with confidential information suitably hosed... === NameVirtualHost *:80 <VirtualHost *:80> ServerAdmin [email protected] ServerName svn.mycompany.com ErrorLog logs/subversion-error_log CustomLog logs/subversion-access_log common Redirect permanent / https://svn.mycompany.com </VirtualHost> <VirtualHost svn.mycompany.com:443> SSLEngine On SSLCertificateFile /etc/httpd/ssl/wildcard.mycompany.com.crt SSLCertificateKeyFile /etc/httpd/ssl/wildcard.mycompany.com.key SSLCertificateChainFile /etc/httpd/ssl/intermediate.crt ServerName svn.mycompany.com ServerAdmin [email protected] ErrorLog logs/subversion-error_log CustomLog logs/subversion-access_log common <Location /svn> DAV svn SVNParentPath /usr/local/subversion SVNListParentPath off AuthName "Subversion Repositories" # NT Logon Details Require valid-user AuthBasicProvider file ldap AuthType Basic AuthzLDAPAuthoritative off AuthUserFile /etc/httpd/conf/svnpasswd AuthName "Subversion Server II" AuthLDAPURL "ldap://our-pdc:389/OU=Company Name,DC=com,DC=co,DC=uk?sAMAccountName?sub?(objectClass=*)" AuthLDAPBindDN "DOMAIN\subversion" AuthLDAPBindPassword XXXXXXX AuthzSVNAccessFile /etc/httpd/conf/svnaccessfile </Location> </VirtualHost> === Now, in ssl_error_log, I get === ==> /etc/httpd/logs/ssl_error_log <== [Fri Nov 01 16:07:55 2013] [error] [client XXX.XXX.XXX.XXX] File does not exist: /var/www/html/svn === This comes from the DocumentRoot directive further up the httpd.conf file, which of course points to /var/www/html. I know that this location is wrong, but how can I get SVN to serve the repo? I tried an Alias directive as so .. Alias /svn /usr/local/subversion .. but this didn't work. I tried to alter the Location directive. That didn't work either. Can someone help? I sense that this is so close to being solved ... Thanks. Edit: apachectl -S output: [root@svn conf]# apachectl -S VirtualHost configuration: 127.0.0.1:443 svn.mycompany.com (/etc/httpd/conf/httpd.conf:1020) wildcard NameVirtualHosts and default servers: default:443 svn.mycompany.com (/etc/httpd/conf.d/ssl.conf:74) *:80 is a NameVirtualHost default server svn.mycompany.com (/etc/httpd/conf/httpd.conf:1012) port 80 namevhost svn.mycompany.com (/etc/httpd/conf/httpd.conf:1012) Syntax OK

    Read the article

  • usb_modeswitch not switching

    - by deniz
    After I upgraded from kernel 2.6.18 to 3.5.3 modeswitch started not to work for me. Although lsusb shows my usb modem, usb_modeswitch does not switch it. My system information is like below. I ran lsusb, dmesg, usb-devices and usb_modeswitch their output is like below. usb_modeswitch instead of switching my modem it says "No devices in default mode found. Nothing to do. Bye.". Can you offer a solution? Kernel: Linux 3.5.3 usb_modeswitch: 1.2.3-1 usb_modeswitch-data: 20120120-1 usbutils: 006-1 libusb: 1.0.8-0.1 root@localhost$ lsusb Bus 002 Device 029: ID 12d1:1446 Huawei Technologies Co., Ltd. root@localhost$ dmesg [70112.477080] usb 2-1.4: new high-speed USB device number 30 using ehci_hcd [70112.567757] scsi49 : usb-storage 2-1.4:1.0 [70112.567842] scsi50 : usb-storage 2-1.4:1.1 [70113.571433] scsi 49:0:0:0: CD-ROM HUAWEI Mass Storage 2.31 PQ: 0 ANSI: 2 [70113.572304] scsi 50:0:0:0: Direct-Access HUAWEI TF CARD Storage PQ: 0 ANSI: 2 [70113.574169] sr0: scsi-1 drive [70113.574223] sr 49:0:0:0: Attached scsi CD-ROM sr0 [70113.574250] sr 49:0:0:0: Attached scsi generic sg1 type 5 [70113.574350] sd 50:0:0:0: Attached scsi generic sg2 type 0 [70113.577173] sd 50:0:0:0: [sdb] Attached SCSI removable disk root@localhost$ usb-devices T: Bus=02 Lev=02 Prnt=02 Port=03 Cnt=01 Dev#= 30 Spd=480 MxCh= 0 D: Ver= 2.00 Cls=00(>ifc ) Sub=00 Prot=00 MxPS=64 #Cfgs= 1 P: Vendor=12d1 ProdID=1446 Rev=00.00 S: Manufacturer=Huawei Technologies S: Product=HUAWEI Mobile C: #Ifs= 2 Cfg#= 1 Atr=c0 MxPwr=500mA I: If#= 0 Alt= 0 #EPs= 2 Cls=08(stor.) Sub=06 Prot=50 Driver=usb-storage I: If#= 1 Alt= 0 #EPs= 2 Cls=08(stor.) Sub=06 Prot=50 Driver=usb-storage root@localhost$ cat /etc/usb_modeswitch.d/12d1\:1446 # Huawei, newer modems TargetVendor= 0x12d1 TargetProductList="1001,1406,140b,140c,1412,141b,1433,1436,14ac,1506" MessageContent="55534243123456780000000000000011062000000100000000000000000000" root@localhost$ usb_modeswitch -c /etc/usb_modeswitch.d/12d1:1446 -v 12d1 -p 1446 -W * usb_modeswitch: handle USB devices with multiple modes * Version 1.2.3 (C) Josua Dietze 2012 * Based on libusb0 (0.1.12 and above) ! PLEASE REPORT NEW CONFIGURATIONS ! DefaultVendor= 0x12d1 DefaultProduct= 0x1446 TargetVendor= 0x12d1 TargetProduct= not set TargetClass= not set TargetProductList="1001,1406,140b,140c,1412,141b,1433,1436,14ac,1506" DetachStorageOnly=0 HuaweiMode=0 SierraMode=0 SonyMode=0 QisdaMode=0 GCTMode=0 KobilMode=0 SequansMode=0 MobileActionMode=0 CiscoMode=0 MessageEndpoint= not set MessageContent="55534243123456780000000000000011062000000100000000000000000000" NeedResponse=0 ResponseEndpoint= not set InquireDevice enabled (default) Success check disabled System integration mode disabled usb_set_debug: Setting debugging level to 15 (on) usb_os_find_busses: Skipping non bus directory devices usb_os_find_busses: Skipping non bus directory drivers usb_os_find_busses: Skipping non bus directory uevent usb_os_find_busses: Skipping non bus directory drivers_probe usb_os_find_busses: Skipping non bus directory drivers_autoprobe Looking for target devices ... No devices in target mode or class found Looking for default devices ... No devices in default mode found. Nothing to do. Bye. Thanks in advance.

    Read the article

  • lacp, cicso 3550, 3560, help with configuration

    - by Flamewires
    Hey all this is a repost from a question I asked on the cisco forums but never got a useful reply. Hey I'm trying to convert the FreeBSD servers at work to dual-gig lagg links from regular gigabit links. Our production servers are on a 3560. I have a small test environment on a 3550. I have achieved fail-over, but am having troubles achieving the speed increase. All servers are running gig intel (em) cards. The configs for the servers are: BSDServer: #!/bin/sh #bring up both interfaces ifconfig em0 up media 1000baseTX mediaopt full-duplex ifconfig em1 up media 1000baseTX mediaopt full-duplex #create the lagg interface ifconfig lagg0 create #set lagg0's protocol to lacp, add both cards to the interface, #and assign it em1's ip/netmask ifconfig lagg0 laggproto lacp laggport em0 laggport em1 ***.***.***.*** netmask 255.255.255.0 The switches are configured as follows: #clear out old junk no int Po1 default int range GigabitEthernet 0/15 - 16 # config ports interface range GigabitEthernet 0/15 - 16 description lagg-test switchport duplex full speed 1000 switchport access vlan 192 spanning-tree portfast channel-group 1 mode active channel-protocol lacp **** switchport trunk encapsulation dot1q **** no shutdown exit interface Port-channel 1 description lagginterface switchport access vlan 192 exit port-channel load-balance src-mac end obviously change 1000's to 100's and GigabitEthernet to FastEthernet for the 3550's config, as that switch has 100Mbit speed ports. With this config on the 3550, I get failover and 92Mbits/sec speed on both links, simultaneously, connecting to 2 hosts.(tested with iperf) Success. However this is only with the "switchport trunk encapsulation dot1q" line. First, I do not understand why I need this, I thought it was only for connecting switches. Is there some other setting which this turns on that is actually responsible for the speed increase? Second, This config does not work on the 3560. I get failover, but not the speed increase. Speeds drop from gig/sec to 500Mbit/sec when I make 2 simultaneous connections to the server with or without the encapsulation line. I should mention that both switches are using source-mac load balancing. In my test I am using Iperf. I have the server(lagg box) setup as the server(iperf -s), and the client computers are client(iperf -c server-ip-address), so the source mac(and IP) are different for both connections. Any ideas/corrections/questions would be helpful, as the gig switches are what I actually need the lagg links on. Ask if you need more information.

    Read the article

  • No Telnet login prompt when used over SSH tunnel

    - by SCO
    Hi there ! I have a device, let's call it d1, runnning a lightweight Linux. This device is NATed by my internet box/router, hence not reachable from the Internet. That device runs a telnet daemon on it, and only has root as user (no pwd). Its ip address is 192.168.0.126 on the private network. From the private network (let's say 192.168.0.x), I can do: telnet 192.168.0.126 Where 192.168.0.126 is the IP address in the private network. This works correctly. However, to allow administration, I'd need to access that device from outside of that private network. Hence, I created an SSH tunnel like this on d1 : ssh -R 4455:localhost:23 ussh@s1 s1 is a server somewhere in the private network (but this is for testing purposes only, it will endup somewhere in the Internet), running a standard Linux distro and on which I created a user called 'ussh'. s1 IP address is 192.168.0.48. When I 'telnet' with the following, let's say from c1, 192.168.0.19 : telnet -l root s1 4455 I get : Trying 192.168.0.48... Connected to 192.168.0.48. Escape character is '^]'. Connection closed by foreign host . The connection is closed after roughly 30 seconds, and I didn't log. I tried without the -l switch, without any success. I tried to 'telnet' with IP addresses instead of names to avoid reverse DNS issues (although I added to d1 /etc/hosts a line refering to s1 IP/name, just in case), no success. I tried on another port than 4455, no success. I gathered Wireshark logs from s1. I can see : s1 sends SSH data to c1, c1 ACK s1 performs an AAAA DNS request for c1, gets only the Authoritave nameservers. s1 performs an A DNS request, then gets c1's IP address s1 sends a SYN packet to c1, c1 replies with a RST/ACK s1 sends a SYN to c1, C1 RST/ACK (?) After 0.8 seconds, c1 sends a SYN to s1, s1 SYN/ACK and then c1 ACK s1 sends SSH content to d1, d1 sends an ACK back to s1 s1 retries AAAA and A DNS requests After 5 seconds, s1 retries a SYN to c1, once again it is RST/ACKed by c1. This is repeated 3 more times. The last five packets : d1 sends SSH content to s1, s1 sends ACK and FIN/ACK to c1, c1 replies with FIN/ACK, s1 sends ACK to c1. The connection seems to be closed by the telnet daemon after 22 seconds. AFAIK, there is no way to decode the SSH stream, so I'm really stuck here ... Any ideas ? Thank you !

    Read the article

  • How to configure Transparent IP Address Sharing (TAS) on a Mediatrix 4102 with DGW 2.0 firmware?

    - by Pascal Bourque
    I am making the switch to VoIP. I chose voip.ms as my service provider and Mediatrix 4102 as my ATA. One reason why I chose the Mediatrix over other popular consumer ATAs is that it's supposed to be easy to place it in front of the router, so it can give priority to its own upstream traffic over the home network's upstream traffic. This is supposed to work transparently, with the ATA and router sharing the same public IP address (the one obtained from the modem). They call this feaure Transparent IP Address Sharing, or TAS. Their promotional brochure describes it like this: The Mediatrix 4102 also uses its innovative TAS (Transparent IP Address Sharing) technology and an embedded PPPoE client to allow the PC (or router) connected to the second Ethernet port to have the same public IP address, eliminating the need for private IP addresses or address translations. I am interested by this feature because my router, an Apple Time Capsule, doesn't support QoS and cannot give priority to the voice packets if the ATA is behind the router. However, after hours of searching the web, reading the documentation, and good ol' trial and error, I haven't been able to configure the Mediatrix to run in this mode. Then I found a version of the manual that looks like it was for a previous version of the firmware (SIP), where there is an entire section dedicated to configuring TAS (starting at page 209). But my Mediatrix comes with the DGW 2.0 firmware, whose documentation does not mention TAS at all. So I tried to follow the TAS setup instructions from the SIP documentation and apply them to my DGW firmware, using the Variable Mapping Between SIP v5.0 and DGW v2.0 document as a reference, but no success. Some required SIP variables don't have an equivalent in DGW. So it looks like the DGW firmware does not support TAS at all, or if it does they are not doing anything to help us set it up. So right now, the Mediatrix is behind the router and VoIP works perfectly except when my upstream bandwidth is saturated. My questions are: Is downgrading to SIP firmware the only way to have my Mediatrix 4102 run in TAS mode? If not, anybody knows how to setup TAS on the DGW firmware? Is TAS mode the only way to give priority to the voice packets if I want to keep my current router (Apple Time Capsule)? Thanks!

    Read the article

  • nginx 502 bad gateway - fastcgi not listening? (Debian 5)

    - by Sean
    I have experience with nginx but it's always been pre-installed for me (via VPS.net pre-configured image). I really like what it does for me, and now I'm trying to install it on my own server with apt-get. This is a fairly fresh Debian 5 install. I have few extra packages installed but they're all .deb's, no manual compiling or anything crazy going on. Apache is already installed but I disabled it. I did apt-get install nginx and that worked fine. Changed the config around a bit for my needs, although the same problem I'm about to describe happens even with the default config. It took me a while to figure out that the default debian package for nginx doesn't spawn fastcgi processes automatically. That's pretty lame, but I figured out how to do that with this script, which I found posted on many different web sites: #!/bin/bash ## ABSOLUTE path to the PHP binary PHPFCGI="/usr/bin/php5-cgi" ## tcp-port to bind on FCGIPORT="9000" ## IP to bind on FCGIADDR="127.0.0.1" ## number of PHP children to spawn PHP_FCGI_CHILDREN=10 ## number of request before php-process will be restarted PHP_FCGI_MAX_REQUESTS=1000 # allowed environment variables sperated by spaces ALLOWED_ENV="ORACLE_HOME PATH USER" ## if this script is run as root switch to the following user USERID=www-data ################## no config below this line if test x$PHP_FCGI_CHILDREN = x; then PHP_FCGI_CHILDREN=5 fi ALLOWED_ENV="$ALLOWED_ENV PHP_FCGI_CHILDREN" ALLOWED_ENV="$ALLOWED_ENV PHP_FCGI_MAX_REQUESTS" ALLOWED_ENV="$ALLOWED_ENV FCGI_WEB_SERVER_ADDRS" if test x$UID = x0; then EX="/bin/su -m -c \"$PHPFCGI -q -b $FCGIADDR:$FCGIPORT\" $USERID" else EX="$PHPFCGI -b $FCGIADDR:$FCGIPORT" fi echo $EX # copy the allowed environment variables E= for i in $ALLOWED_ENV; do E="$E $i=${!i}" done # clean environment and set up a new one nohup env - $E sh -c "$EX" &> /dev/null & When I do a "ps -A | grep php5-cgi", I see the 10 processes running, that should be ready to listen. But when I try to view a web page via nginx, I just get a 502 bad gateway error. After futzing around a bit, I tried telneting to 127.0.0.1 9000 (fastcgi is listening on port 9000, and nginx is configured to talk to that port), but it just immediately closes the connection. This makes me think the problem is with fastcgi, but I'm not sure what I can do to test it. It may just be closing the connection because it's not getting fed any data to process, but it closes immediately so that makes me think otherwise. So... any advice? I can't figure it out. It doesn't help that it's 1AM, but I'm going crazy here!

    Read the article

  • debian gateway using iptables

    - by meijuh
    I am having problems setting up a debian gateway server. My goal: Having eth1 the WAN interface. Having eth0 the LAN interface. Allow both ports 22 (SSH) and 80 (HTTP) accessed from the outside world on the gateway (SSH and HTTP run on this server). What I did was the following: Create a file /etc/iptables.rules with contents: /etc/iptables.rules: *nat -A POSTROUTING -o eth1 -j MASQUERADE COMMIT *filter -A INPUT -i lo -j ACCEPT -A INPUT -m state --state RELATED,ESTABLISHED -j ACCEPT -A INPUT -i eth1 -p tcp -m tcp --dport 22 -j ACCEPT -A INPUT -i eth1 -p tcp -m tcp --dport 80 -j ACCEPT -A INPUT -i eth1 -j DROP COMMIT edit /etc/network/interfaces as follows: /etc/network/interfaces: # The loopback network interface auto lo iface lo inet loopback pre-up iptables-restore < /etc/iptables.rules auto eth0 allow-hotplug eth0 iface eth0 inet dhcp #auto eth1 #allow-hotplug eth1 #iface eth1 inet dhcp allow-hotplug eth1 iface eth1 inet static address 217.119.224.51 netmask 255.255.255.248 gateway 217.119.224.49 dns-nameservers 217.119.226.67 217.119.226.68 Uncomment the rule net.ipv4.ip_forward=1 in /etc/sysctl.conf to allow packet forwarding. The static settings for eth1 such as the ip address I got from my router (which I want to replace); I simply copied these. I have a (windows) DNS + DHCP server on ip address 10.180.1.10, which assigns ip address 10.180.1.44 to eth0. What this server does is not really interesting it only maps domain names on our local network and assigns one static ip to the gateway. What works: on the gateway itself I can ping 8.8.8.8 and google.nl. So that is okey. What does not work: (1) Every machine connected to eth0 (indirectly via a switch) can not ping an ip or a domain. So I guess the gateway can not be found. (2) Also when I configure my linux machine (a laptop) to use a static ip 10.180.1.41, a mask and a gateway (10.180.1.44) I can not ping an ip or domain either. This means that maybe my iptables is incorrect of not loaded correctly. Or I maybe have to configure my DNS/DHCP on my windows machine. I have not reset the windows machine net, restart the DNS/DHCP services, should I do this? I did not install dnsmasq as desribed here: http://blog.noviantech.com/2010/12/22/debian-router-gateway-in-15-minutes/. I don't think this is necessary?

    Read the article

  • Firefox: non-Vimperator way to do mouseless browsing?

    - by Peter Mortensen
    Is it possible to do efficient browsing with Firefox using only the keyboard (like in Opera)? By efficient I mean something faster than using TAB - this takes far too long. The arrow keys should be for navigation (in Opera it is Shift + arrow key). It can done with the Vimperator add-on, but isn't there a simpler way? Update 2: the closest to Opera's way is to enable caret navigation (F7 toggles this mode). It doesn't jump between links so it is a little bit slower, but the normal navigation (arrow keys, page up, page down, etc.) works and the focus/caret/cursor follows (in contrast to a text editor for page up/down). And text can be selected and copied like in a text editor. The biggest drawback is that in practice it is necessary to switch in and out of caret mode. And there is no indication of which mode is currently active. Update 1: a work-around (proposed by several but is not really what I am looking for) can be used if 3 settings are changed (to make it practical). After these changes the first few letters of a link text can be typed and that link will selected so pressing Enter will open it. Using the work-around the screen will jump around if it is a long page as it does not restrict itself to the current visible page, but it is usable. First settings change: menu Tools/Options/Advanced/tab General/Accessibility/Search for text when I start typing Turn this option on. Second settings change: set option to only go to links; in address bar enter: about:config followed by Enter. Then: press "I'll be careful, I promise", find the line accessibility.typeaheadfind.linksonly, select it and change the value to True by either hitting Enter or Shift+F10/Toggle (accessibility.typeaheadfind.linksonly is on line 11 when I tried). Third settings change: turn off case-sensitivity. Set accessibility.typeaheadfind.casesensitive to 0 (same procedure as for accessibility.typeaheadfind.linksonly, see above. When Enter is pressed a dialog box will appear with the current value. Type 0 and press Enter). To use: type some part of the link. If there are several possibilities use Ctrl+G (or F3) to jump between them. Use Ctrl+Enter to open in a new tab. Platform: Firefox 3.0.6, Windows XP 64 bit SP2.

    Read the article

  • what is Remote Desktop Services in Windows Server 2008 R2 all about?

    - by fejesjoco
    Seriously, I'm lost in all that sales mumbo-jumbo. Let's say I want 1 or 2 users to be able to remotely log on to a server, run Word, Visual Studio, Firefox, and whatever. Do I gain anything at all if I install Remote Desktop Services? Or do I just install Desktop Experience feature pack, enable remote desktop and voila, nobody will ever notice the difference? Here's what TechNet says about Remote Desktop Session Host: A Remote Desktop Session Host (RD Session Host) server is the server that hosts Windows-based programs or the full Windows desktop for Remote Desktop Services clients. Users can connect to an RD Session Host server to run programs, to save files, and to use network resources on that server. Users can access an RD Session Host server by using Remote Desktop Connection or by using RemoteApp. The good old simple remote desktop can also host a full Windows desktop for remote clients so that they can run programs, save files and do all that stuff. Why do they write about it like it's such a great new invention, besides that they want to sell it? RDSH doesn't seem all that different at all. What do I install when I install RDSH, since all those features are already there in Windows? What's even more confusing is that you need to take special care when you want to install applications to an RDSH so that they will be usable by many concurrent users. Why? All the modern applications install the program files in one directory, store some common settings in the ProgramData folder and the HKLM hive, and store user specific settings in the Users folder and the HKCU hive. They are designed to be usable by many users on the same machine. 2 or 2000 users can use them concurrently without any efforts. I can sign in with 2 users to a server with only remote desktop enabled, and both of us can run Word or anything without any problems, can't we? So what changes if I set RDSH to install mode, or what happens if I don't? Why is the feature to switch between install and execute mode there at all? Yes I know of some advantages in Remote Desktop Services, like there's no 2 user limit, it supports virtualization, video acceleration and stuff, it has a whole infrastructure with gateway, web access, connection broker, etc. But I don't need those, so if you take these away, how are these two technologies different? From the articles it seems like they are completely different technologies, whereas it looks to me that they are completely the same at the core, and Remote Desktop Services just adds some additional features, but doesn't reinvent anything.

    Read the article

  • Looking for a NTP Server Software for Windows

    - by Simon
    I'm looking for a, preferably free, NTP Server for Windows Server 2003/2008. We have already tried the built in Windows Time Server, but our tests did show that it is not very accurate, we see time differences up to 500ms. The max time difference we can allow for our application is ~100ms. Now we have already used the Meinberg NTPd for Windows. It works great except we have one big issue with it: If there is a network connection problem between the client and server, the ntp server is in a panic state It won't give the client a new time until we restart the ntp service. This is a big issue which has caused us some trouble. It was working fine for months until there was a network problem we didn't notice, we only noticed it after a week when the time difference was already 30 sec. on the clients. So please suggest some alternative NTP Server for windows. I did Google but I get a lot of unrelated search results. Edit: So far the ntpd windows version was very accurate and I'd like to stick with it. The only problem is the "panic state" after a network disconnect. Maybe some knows here what the cause of this is and how to fix it. Also, I forgot to mention that we have a server/client setup like this: Server1 -- Server2 -- Server3 -- Client1 -- Client2 -- Client3 So Server2 gets its time from Server1, Server3 gets its time from Server2, and the Clients get their time from Server3. Also, there are clients connected directly to Server2. It is important that all Servers and Clients have the exact same time (within ~100ms) Now there was a network problem with Server3 and its clients. The servers run the ntpd port for Windows, which acts as NTP server and client. The clients have Dimension4 as NTP client. After the network problem, the error message in D4 was something like this (out the top of my head, don't have the exact error message): Server response: The server is in a panic state (could not sync clock) I read through the ntpd docs, and the only mention of "panic" is when the time difference is 10000 seconds which will cause to exit the ntpd server but this was not the case. Also there is a "-g" command line switch to disable the panic exit, but it is already set by default. Any ideas what could cause the panic state and how to get rid of it next time?

    Read the article

< Previous Page | 281 282 283 284 285 286 287 288 289 290 291 292  | Next Page >