  • VS.NET solution built differently on build server

    - by slolife
    I have a VS.NET solution with two Projects, ProjectWeb and ProjectLibrary. PW depends on PL, so I have a VS.NET project reference to PL in PW. That works all well and good on my dev box, but when it all gets to the build server, I have two different build projects, one for PL and one for PW. I'd like to build PL and copy the binaries somewhere. Then, I'd like to build PW and it only, using the binaries from the previous PL build. But will that work since the PW VS.NET project is referencing a project that doesn't exist when I build PW only on the build server? How can I set this up For specifics, I am using CC.NET and NAnt, but I have other projects that use Hudson and straight MS build

    Read the article

  • Signing 3rd Party Assemblies leads to them turnign invisible!

    - by Andrew
    Hi All, I followed OJ's instructions here This allowed me to successfully breakdown, then rebuild and sign some 3rd party DLLs. Here's what I did: Dissassembled Old.dll Rebuild and signed as New.dll (using the same *.snk that my VS2005 proj is signed with) Removed all references in my proj to Old.dll and added references to New.dll Replaced 'Imports Old.dll' with 'Imports New.dll' this final step fails. VS2005 won't recognise my New.dll Any clues?

    Read the article

  • VSC++, virtual method at bad adress, curious bug

    - by antoon.groenewoud
    Hello, This guy: virtual phTreeClass* GetTreeClass() const { return (phTreeClass*)m_entity_class; } When called, crashed the program with an access violation, even after a full recompile. All member functions and virtual member functions had correct memory adresses (I hovered mouse over the methods in debug mode), but this function had a bad memory adress: 0xfffffffc. Everything looked okay: the 'this' pointer, and everything works fine up until this function call. This function is also pretty old and I didn't change it for a long time. The problem just suddenly popped up after some work, which I commented all out to see what was doing it, without any success. So I removed the virtual, compiled, and it works fine. I add virtual, compiled, and it still works fine! I basically changed nothing, and remember that I did do a full recompile earlier, and still had the error back then. I wasn't able to reproduce the problem. But now it is back. I didn't change anything. Removing virtual fixes the problem. Sincerely, Antoon

    Read the article

  • how can i program this ui box

    - by silverkid
    in what way can this be programmed. a UI box that displays random number between min and max value for 2 seconds then shows blank for 2 seconds then shows another random numer for 2 seconds then shows blank for 10 seonds and then repeats the cycle infitely until form closed. Font of the text to be configurable. any help at all will be appreciated.

    Read the article

  • How can I detect if the Solution is initializing using the DTE in a VisualStudio extension?

    - by justin.m.chase
    I am using the DTE to track when projects are loaded and removed from the solution so that I can update a custom Test Explorer extension. I then trigger a container discovery process. But when the solution is first loaded it does an asynchronous load of some projects and fires a lot of Project Added events. What I would really like to do is to ignore all of these events until the solution is done loading. I can't quite figure out the order of events such that I know for sure that this initialization process has completed. It would be really nice to be able to just query the solution object and ask it. Does anyone know if there is a property or interface or event that I can use to determine this?

    Read the article

  • How to Compute a Database Column in .NET

    - by Michael
    I have a Database named CarsType.accdb there are four fields in the data base Item_Name, Item_Num, Item_Qty, Item_Cost. I am able to get the database to display my data in VisualBasic but I am not sure how to get the total cost to appear in my label (lblTotalCost). I prefer doing it in VB versus writing in my access program. All I am wanting to do it multiply item_qty * Item_Cost How would I go about doing that?

    Read the article

  • C++/CLI: CA2123: Requires SecurityCriticalAttribute?

    - by TomTom
    I am a little lost on erros like that: Warning 7 CA2123 : Microsoft.Security : Add the following security attribute to 'RithmicConnector::Connect(String^)' in order to match a LinkDemand on base method 'IConnector::Connect(String^)': 'SecurityCriticalAttribute'. c:\work\nettecture\tradex\source\tradex.connectivity.rithmic\rithmicconnector.cpp 52 Tradex.Connectivity.Rithmic Where do I add the SecurityCriticalAttribute? I tried on the header file - but the error does not disappear. I have one of those pretty much on every exposed method of a (managed C++) interface DLL. And I want CA to run through. How do I fix those? Regards

    Read the article

  • Adventures on Enterprise Library 5.0: Who moved my cheese (namespace)

    - by Junior Mayhé
    Jesus, Krishna, Budda! I've migrated to EntLib 5.0, but classes like ISymmetricCryptoProvider are not recognized anymore. Funny to say that Data, Logging and other blocks are working compiling fine. Here's the problematic class: using System; using System.Collections.Generic; using System.Text; using Microsoft.Practices.EnterpriseLibrary.Common.Configuration;//-->it's not working anymore using Microsoft.Practices.EnterpriseLibrary.Security.Cryptography;//-->it's not working anymore namespace MyClassLibrary.Security.EnterpriseLibrary { public sealed class Crypto { public static ISymmetricCryptoProvider MyProvider { get { //IConfigurationSource is not recognized either, neither SystemConfigurationSource IConfigurationSource cs = new SystemConfigurationSource(); SymmetricCryptoProviderFactory scpf = new SymmetricCryptoProviderFactory(cs); ISymmetricCryptoProvider p = scpf.CreateDefault(); return p; } } The references are fine on project too. I really don't know why this particular project it's causing too many trouble on VS2010! Older references were deleted, project was cleaned, rebuilt, but can't make it compile :-( The references are: Microsoft.Practices.EnterpriseLibrary.Common Microsoft.Practices.EnterpriseLibrary.Logging Microsoft.Practices.EnterpriseLibrary.Logging.Database Microsoft.Practices.EnterpriseLibrary.Security Microsoft.Practices.EnterpriseLibrary.Security.Cryptography Why some namespaces can be found while others can't?

    Read the article

  • Can Microsoft Visual C++ 2008 Redistributable Package be freely redistributed

    - by luc
    I am planning to use py2exe to make an application developped with Python 2.6. It seems that my app need the VC redistribuables : http://www.py2exe.org/index.cgi/Tutorial#Step5 I've read this tutorial and the redistribuables license agreement and I am not sure if I can freely redistribute these files with my program. (I don't have VS2008 license) Can I bundle the redistribs into an installer and make the installation transparent for the user or do they have to download the files by their own from Microsoft website? Thanks in advance

    Read the article

  • DataGridView: Scroll bar does not refreshed

    - by David.Chu.ca
    I am working (fixing bugs) on a project which was written in VS 2005. There is one DataGridView control on a form. When it is first time loaded, the control's data grid is populated with rows of data from a collection manually or in codes. Actually, there is method PopulateDataGrid() do the job. There is also another control on the form. When control is changed, the data grid will be cleared first and then rows are repopulated again through PopulateDataGrid(). The problem is that when the grid is refreshed, the vertical scroll bar does not get reset correctly. I thought it should be. Since the scroll bar is not reset, when I tried to click on grid and move down, I got exception: the max value of scroll bar was exceeded. All the settings for grid control are default values. For example, the ScrollBars is Both. The following is the only related place to set row auto size property: poDataGridView.AutoSizeRowsMode = DataGridViewAutoSizeRowsMode.DisplayedCellsExceptHeaders; I am not sure if there is any property I have to set in designer?

    Read the article

  • WCF Service error received when using TCP: "The message could not be dispatched..."

    - by StM
    I am new to creating WCF services. I have created a WCF web service in VS2008 that is running on IIS 7. When I use http the service works perfectly. When I configure the service for TCP and run I get the following error message. There was a communication problem. The message could not be dispatched because the service at the endpoint address 'net:tcp://elec:9090/CoordinateIdTool_Tcp/IdToolService.svc is unavailable for the protocol of the address. I have searched a lot of forums, including this one, for a resolution but nothing has worked. Everything appears to be set up correctly on IIS 7. WAS has been set up to run. The default web site has a net.tcp binding and the application has net.tcp under the enabled protocols. I am including what I think is the important part of the web.config from the host project and also the app.config from the client project I am using to test the service. Hopefully someone can spot my error. Thanks in advance for any help or recommendations that anyone can provide. Web.Config <bindings> <wsHttpBinding> <binding name="wsHttpBindingNoMsgs"> <security mode="None" /> </binding> </wsHttpBinding> </bindings> <services> <service behaviorConfiguration="CogIDServiceHost.ServiceBehavior" name="CogIDServiceLibrary.CogIdService"> <endpoint address="" binding="wsHttpBinding" bindingConfiguration="wsHttpBindingNoMsgs" contract="CogIDServiceLibrary.CogIdTool"> <identity> <dns value="localhost" /> </identity> </endpoint> <endpoint address="mex" binding="mexHttpBinding" bindingConfiguration="" contract="IMetadataExchange" /> <endpoint name="CoordinateIdService_TCP" address="net.tcp://elec:9090/CoordinateIdTool_Tcp/IdToolService.svc" binding="netTcpBinding" bindingConfiguration="" contract="CogIDServiceLibrary.CogIdTool"> <identity> <dns value="localhost" /> </identity> </endpoint> </service> </services> <behaviors> <serviceBehaviors> <behavior name="CogIDServiceHost.ServiceBehavior"> <serviceMetadata httpGetEnabled="true" /> <serviceDebug includeExceptionDetailInFaults="false" /> </behavior> </serviceBehaviors> </behaviors> App.Config <system.serviceModel> <diagnostics performanceCounters="Off"> <messageLogging logEntireMessage="true" logMalformedMessages="false" logMessagesAtServiceLevel="false" logMessagesAtTransportLevel="false" /> </diagnostics> <behaviors /> <bindings> <wsHttpBinding> <binding name="WSHttpBinding_CogIdTool" closeTimeout="00:01:00" openTimeout="00:01:00" receiveTimeout="00:10:00" sendTimeout="00:01:00" bypassProxyOnLocal="false" transactionFlow="false" hostNameComparisonMode="StrongWildcard" maxBufferPoolSize="524288" maxReceivedMessageSize="65536" messageEncoding="Text" textEncoding="utf-8" useDefaultWebProxy="true" allowCookies="false"> <readerQuotas maxDepth="32" maxStringContentLength="8192" maxArrayLength="16384" maxBytesPerRead="4096" maxNameTableCharCount="16384" /> <reliableSession ordered="true" inactivityTimeout="00:10:00" enabled="false" /> <security mode="None"> <transport clientCredentialType="Windows" proxyCredentialType="None" realm="" /> <message clientCredentialType="Windows" negotiateServiceCredential="true" establishSecurityContext="true" /> </security> </binding> <binding name="wsHttpBindingNoMsg"> <security mode="None"> <transport clientCredentialType="Windows" /> <message clientCredentialType="Windows" /> </security> </binding> </wsHttpBinding> </bindings> <client> <endpoint address="http://sdet/CogId_WCF/IdToolService.svc" binding="wsHttpBinding" bindingConfiguration="wsHttpBindingNoMsg" contract="CogIdServiceReference.CogIdTool" name="IISHostWsHttpBinding"> <identity> <dns value="localhost" /> </identity> </endpoint> <endpoint address="http://localhost:1890/IdToolService.svc" binding="wsHttpBinding" bindingConfiguration="WSHttpBinding_CogIdTool" contract="CogIdServiceReference.CogIdTool" name="WSHttpBinding_CogIdTool"> <identity> <dns value="localhost" /> </identity> </endpoint> <endpoint address="http://elec/CoordinateIdTool/IdToolService.svc" binding="wsHttpBinding" bindingConfiguration="wsHttpBindingNoMsg" contract="CogIdServiceReference.CogIdTool" name="IIS7HostWsHttpBinding_Elec"> <identity> <dns value="localhost" /> </identity> </endpoint> <endpoint address="net.tcp://elec:9090/CoordinateIdTool_Tcp/IdToolService.svc" binding="netTcpBinding" bindingConfiguration="" contract="CogIdServiceReference.CogIdTool" name="IIS7HostTcpBinding_Elec" > <identity> <dns value="localhost"/> </identity> </endpoint> </client> </system.serviceModel>

    Read the article

  • Registry entry using VC++, Data corrupting

    - by sijith
    Hi I want to set system time to registry, i did like this. But some null characters only getting there. when i am giving LPCTSTR data = TEXT("24/3/2010\0"); LONG setRes = RegSetValueEx (hkey, value, 0, REG_SZ, (LPBYTE)data, 100)); thsi is sucessfully adding into registry How to trace the issue IF possible please check my code include include include void Regkey::create_Registry() { HKEY hkey; DWORD dwDisposition,lpData; SYSTEMTIME time; GetLocalTime( &time ); int hour = time.wHour; if (hour 12) hour -= 12; char szData[20]; sprintf (szData, "%02d/%02d/%04d", time.wDay, time.wMonth, time.wYear); if(RegCreateKeyEx(HKEY_LOCAL_MACHINE, TEXT("Software\Sijith\Test"), 0, NULL, 0, 0, NULL, &hkey, &dwDisposition)== ERROR_SUCCESS) { LPCTSTR sk = TEXT("Software\Sijith\Test"); LONG openRes = RegOpenKeyEx(HKEY_LOCAL_MACHINE, sk, 0, KEY_ALL_ACCESS , &hkey); LPCTSTR value = TEXT("CheckSoftwareKey"); LONG setRes = RegSetValueEx (hkey, value, 0, REG_SZ, (CONST BYTE *)szData, sizeof(TCHAR) * (_tcslen(szData) + 1)); RegCloseKey(hkey); } } output value name: CheckSoftwareKey valueData: ?????

    Read the article

  • resources at class library project

    - by Night Walker
    Hello I want to add some xml file as resource to my class library project . Any idea how to do so , and call it later? In windows application i would do it like ClassLibrary1.Properties.Resources.file.xml But here it didn't worked any idea how i do it here ?

    Read the article

  • How can a wix custom action dll call be made to use the debug runtime via a merge module?

    - by Benj
    I'm trying to create a debug build with a corresponding debug installer for our product. I'm new to Wix so please forgive any naivety contained herein. The debug Dlls in my project are dependent on both the VS2008 and the VS2008SP1 debug runtimes. I've created a merge module feature in wix to bundle those runtimes with my installer. <Include xmlns="http://schemas.microsoft.com/wix/2006/wi"> <!-- Include our 'variables' file --> <!--<?include variables.wxi ?>--> <!--<Fragment>--> <DirectoryRef Id="TARGETDIR"> <!-- Always install the 32 bit ATL/CRT libraries, but only install the 64 bit ones on a 64 bit build --> <Merge Id="AtlFiles_x86" SourceFile="$(env.CommonProgramFiles)\Merge Modules\Microsoft_VC90_ATL_x86.msm" DiskId="1" Language="1033"/> <Merge Id="AtlPolicy_x86" SourceFile="$(env.CommonProgramFiles)\Merge Modules\policy_9_0_Microsoft_VC90_ATL_x86.msm" DiskId="1" Language="1033"/> <Merge Id="CrtFiles_x86" SourceFile="$(env.CommonProgramFiles)\Merge Modules\Microsoft_VC90_DebugCRT_x86.msm" DiskId="1" Language="1033"/> <Merge Id="CrtPolicy_x86" SourceFile="$(env.CommonProgramFiles)\Merge Modules\policy_9_0_Microsoft_VC90_DebugCRT_x86.msm" DiskId="1" Language="1033"/> <Merge Id="MfcFiles_x86" SourceFile="$(env.CommonProgramFiles)\Merge Modules\Microsoft_VC90_DebugMFC_x86.msm" DiskId="1" Language="1033"/> <Merge Id="MfcPolicy_x86" SourceFile="$(env.CommonProgramFiles)\Merge Modules\policy_9_0_Microsoft_VC90_DebugMFC_x86.msm" DiskId="1" Language="1033"/> <!-- If this is a 64 bit build, install the relevant modules --> <?if $(env.Platform) = "x64" ?> <Merge Id="AtlFiles_x64" SourceFile="$(env.CommonProgramFiles)\Merge Modules\Microsoft_VC90_ATL_x86_x64.msm" DiskId="1" Language="1033"/> <Merge Id="AtlPolicy_x64" SourceFile="$(env.CommonProgramFiles)\Merge Modules\policy_9_0_Microsoft_VC90_ATL_x86_x64.msm" DiskId="1" Language="1033"/> <Merge Id="CrtFiles_x64" SourceFile="$(env.CommonProgramFiles)\Merge Modules\Microsoft_VC90_DebugCRT_x86_x64.msm" DiskId="1" Language="1033"/> <Merge Id="CrtPolicy_x64" SourceFile="$(env.CommonProgramFiles)\Merge Modules\policy_9_0_Microsoft_VC90_DebugCRT_x86_x64.msm" DiskId="1" Language="1033"/> <Merge Id="MfcFiles_x64" SourceFile="$(env.CommonProgramFiles)\Merge Modules\Microsoft_VC90_DebugMFC_x86_x64.msm" DiskId="1" Language="1033"/> <Merge Id="MfcPolicy_x64" SourceFile="$(env.CommonProgramFiles)\Merge Modules\policy_9_0_Microsoft_VC90_DebugMFC_x86_x64.msm" DiskId="1" Language="1033"/> <?endif?> </DirectoryRef> <Feature Id="MS2008_SP1_DbgRuntime" Title="VC2008 Debug Runtimes" AllowAdvertise="no" Display="hidden" Level="1"> <!-- 32 bit libraries --> <MergeRef Id="AtlFiles_x86"/> <MergeRef Id="AtlPolicy_x86"/> <MergeRef Id="CrtFiles_x86"/> <MergeRef Id="CrtPolicy_x86"/> <MergeRef Id="MfcFiles_x86"/> <MergeRef Id="MfcPolicy_x86"/> <!-- 64 bit libraries --> <?if $(env.Platform) = "x64" ?> <MergeRef Id="AtlFiles_x64"/> <MergeRef Id="AtlPolicy_x64"/> <MergeRef Id="CrtFiles_x64"/> <MergeRef Id="CrtPolicy_x64"/> <MergeRef Id="MfcFiles_x64"/> <MergeRef Id="MfcPolicy_x64"/> <?endif?> </Feature> <!--</Fragment>--> </Include> If I'm doing a debug build of the installer, I include that feature like so: <!-- The 'Feature' that contains the debug CRT/ATL libraries --> <?if $(var.Configuration) = "Debug"?> <?include ..\includes\MS2008_SP1_DbgRuntime.wxi?> <?endif?> The only problem is that my installer also includes a custom action which is also dependent on the debug runtime: <!-- Private key installer --> <Binary Id="InstallPrivateKey" SourceFile="..\InstallPrivateKey\win32\$(var.Configuration)\InstallPrivateKey.dll"></Binary> <CustomAction Id='InstallKey' BinaryKey='InstallPrivateKey' DllEntry='InstallPrivateKey'/> So how can I package the debug run time in such a way that the custom action also has access to it?

    Read the article

  • Publish web application from MSBuild Script using VS2010 targets resets working directory

    - by Raoul
    I am trying to automatically publish and deploy my .Net 4 web application automatically from a build script to be run by our continuous integration server. I am using the new _WPPCopyWebApplication target from VS2010 to perform the publish, however it appears to reset the current working directory of the msbuild project to c:\ this causes my prebuild steps to fail as they have relative paths to some external tools. The task I am running from our master.build file is as follows: <Target Name="PublishWeb"> <MSBuild Projects="$(ProjectPath)" Targets="ResolveReferences;_WPPCopyWebApplication" Properties="WebProjectOutputDir=$(DeployPath);OutDir=$(TempOutputFolder)$(WebOutputFolder)\;OutputPath=$(ProjectPath)\bin\Debug;" /> </Target> This does not happen when using the legacy _CopyWebApplication. Does anyone have any idea how to resolve this problem?

    Read the article

  • Visual Basic Express 2008 Help

    - by khalidfazeli
    I have been given a task to: Develop a program where a child will be presented with picture of a fruit (one of five possible fruit) on the screen at the click of a start button. The child will then try to recognise the fruit and write its name in a specified place on the screen. On the click of a check button the name of the fruit written by the child will be checked by your program and if correct will reward the child with a suitable message. If the name presented by the child is not correct, a suitable message should be presented on a red background with the correct name of the fruit included in the message. so far I have managed to create a form with 5 different fruit pictures and a text box below them. a button at the bottom of the form then checks the results and presents a message box to tell them if they have passed or failed. Private Sub btnResults_Click(ByVal sender As System.Object, ByVal e As System.EventArgs) Handles btnResults.Click If txtApple.Text = "APPLE" And txtOrange.Text = "ORANGES" And txtStrawberry.Text = "STRAWBERRIES" And txtGrapes.Text = "GRAPES" And txtBanana.Text = "BANANAS" Then MsgBox("Congratulations! you got it all right!", MsgBoxStyle.OkOnly) End Else MsgBox("Incorrect, please try again", MsgBoxStyle.OkOnly) End End If End Sub but I can't get it to randomise the picture of the fruit, so it only displays one fruit at a time and checks against it. Any help is appreciated. Thanks

    Read the article

  • Is there a way to add extra fields to an association in the ADO.NET Entity Framework?

    - by bigbird1040
    I would like to be able to model a many-to-many relationship that has extra details about the relationship. For example: Person: int id, String name Project: int id, String name ProjectPerson: Person.id, Project.id, String role Whenever I create the ProjectPerson association in the EF, I am unable to add the role attribute to the association. If I create the tables in my DB and then import it into the model, I lose the extra properties.

    Read the article

  • std::vector optimisation required

    - by marcp
    I've written a routine that uses std::vector<double> rather heavily. It runs rather slowly and AQTime seems to imply that I am constructing mountains of vectors but I'm not sure why I would be. For some context, my sample run iterates 10 times. Each iteration copies 3 c arrays of ~400 points into vectors and creates 3 new same sized vectors for output. Each output point might be the result of summing up to 20 points from 2 of the input vectors, which works out to a worst case of 10*400*3*2*20 = 480,000 dereferences. Incredibly the profiler indicates that some of the std:: methods are being called 46 MILLION times. I suspect I'm doing something wrong! Some code: vector<double>gdbChannel::GetVector() { if (fHaveDoubleData & (fLength > 0)) { double * pD = getDoublePointer(); vector<double>v(pD, pD + fLength); return v; } else { throw(Exception("attempt to retrieve vector on empty line")); ; } } void gdbChannel::SaveVector(GX_HANDLE _hLine, const vector<double> & V) { if (hLine != _hLine) { GetLine(_hLine, V.size(), true); } GX_DOUBLE * pData = getDoublePointer(); memcpy(pData, &V[0], V.size()*sizeof(V[0])); ReplaceData(); } ///This routine gets called 10 times bool SpecRatio::DoWork(GX_HANDLE_PTR pLine) { if (!(hKin.GetLine(*pLine, true) && hUin.GetLine(*pLine, true) && hTHin.GetLine(*pLine, true))) { return true; } vector<double>vK = hKin.GetVector(); vector<double>vU = hUin.GetVector(); vector<double>vTh = hTHin.GetVector(); if ((vK.size() == 0) || (vU.size() == 0) || (vTh.size() == 0)) { return true; } ///TODO: confirm all vectors the same lenghth len = vK.size(); vUK.clear(); // these 3 vectors are declared as private class members vUTh.clear(); vThK.clear(); vUK.reserve(len); vUTh.reserve(len); vThK.reserve(len); // TODO: ensure everything is same fidincr, fidstart and length for (int i = 0; i < len; i++) { if (vK.at(i) < MinK) { vUK.push_back(rDUMMY); vUTh.push_back(rDUMMY); vThK.push_back(rDUMMY); } else { vUK.push_back(RatioPoint(vU, vK, i, UMin, KMin)); vUTh.push_back(RatioPoint(vU, vTh, i, UMin, ThMin)); vThK.push_back(RatioPoint(vTh, vK, i, ThMin, KMin)); } } hUKout.setFidParams(hKin); hUKout.SaveVector(*pLine, vUK); hUTHout.setFidParams(hKin); hUTHout.SaveVector(*pLine, vUTh); hTHKout.setFidParams(hKin); hTHKout.SaveVector(*pLine, vThK); return TestError(); } double SpecRatio::VValue(vector<double>V, int Index) { double result; if ((Index < 0) || (Index >= len)) { result = 0; } else { try { result = V.at(Index); if (OasisUtils::isDummy(result)) { result = 0; } } catch (out_of_range) { result = 0; } } return result; } double SpecRatio::RatioPoint(vector<double>Num, vector<double>Denom, int Index, double NumMin, double DenomMin) { double num = VValue(Num, Index); double denom = VValue(Denom, Index); int s = 0; // Search equalled 10 in this case while (((num < NumMin) || (denom < DenomMin)) && (s < Search)) { num += VValue(Num, Index - s) + VValue(Num, Index + s); denom += VValue(Denom, Index - s) + VValue(Denom, Index + s); s++; } if ((num < NumMin) || (denom < DenomMin)) { return rDUMMY; } else { return num / denom; } } The top AQTime offenders are: std::_Uninit_copy , double *, std::allocator 3.65 secs and 115731 Hits std::_Construct 1.69 secs and 46450637 Hits std::_Vector_const_iterator ::operator !=1.66 secs and 46566395 Hits and so on... std::allocator<double>::construct, operator new, std::_Vector_const_iterator<double, std::allocator<double> >::operator ++, std::_Vector_const_iterator<double, std::allocator<double> >::operator * std::_Vector_const_iterator<double, std::allocator<double> >::operator == each get called over 46 million times. I'm obviously doing something wrong to cause all these objects to be created. Can anyone see my error(s)?

    Read the article

  • Is it possible for two VS2008 C# class library projects to share a single namespace?

    - by jeah
    I am trying to share a common namespace between two projects in a single solution. The projects are "Blueprint" and "Repositories". Blueprint contains Interfaces for the entire application and serves as a reference for the application structure. In the Blueprint project, I have an interface with the following declaration: namespace Application.Repositories{ public interface IRepository{ IEntity Get(Guid id); } } In the Repositories project I have a class the following class: namespace Application.Repositories{ public class STDRepository: IRepository { STD Get(Guid id){ return new SkankyExGirlfriendDataContext() .FirstOrDefault<STD>(x=>x.DiseaseId == id); } } } However, this does not work. The Repositories project has a reference to the Blueprint project. I receive a VS error: "The type or namespace name 'IRepository' could not be found (are you missing a using directive or an assembly reference?) - Normally, this is easy to fix but adding a using statement doesn't make sense since they have the same namespace. I tried it anyway and it didn't work. The reference has been added, and without the line of code referencing that interface, both projects compile successfully. I am lost here. I have searched all over and have found nothing, so I am assuming that there is something fundamentally wrong with what I'm doing ... but I don't know what it is. So, I would appreciate some explanation or guidance as to how to fix this problem. I hope you guys can help. Note: The reason I want to do it this way and keep the interfaces under the same namespace is because I want a solid project to keep all the interfaces in, in order to have a reference for the full architecture of the application. I have considered work arounds, such as putting all of the interfaces in the Blueprint.Application namespace instead of the application namespace. However, that would require me to write the using statement on virtually every page in the application...and my fingers get tired. Thanks again guys...

    Read the article