  • Minimum specs needed to run 1080p HD movies?

    - by Wesley
    Hi all, I was wondering how low you could go with hardware that would still be able to smoothly run HD movies. My current plan is around $215 CAD w/o a hard drive: Intel Pentium 4 @ 3.2 GHz - 1GB DDR/SDRAM - 512MB X1600 Pro AGP - 350W PSU - ECS P4VXASD2+ - Bluray/DVD-RW drive. As for the hard drive, could I just get a 7200RPM IDE HDD? Also, I'm planning on installing XP Pro SP3, unless Ubuntu somehow has an advantage. I'm not wanting this to be a media center only computer... just want it to be a normal computer with just enough oomph to play HD movies. Thanks in advance. EDIT1: Forgot to mention that the Bluray/DVD-RW drive is SATA, but I was planning on getting an SATA-IDE adapter or a PCI card with SATA. EDIT2: Oh yes... if I get a PCI card with SATA, would you then recommend I use an SATA hard drive as well? That would leave all the IDE ports on the motherboard unused... is that a good idea?

    Read the article

  • Quad channel memory and compatibility

    - by balteo
    My motherboard has quad channel memory compatibility. There are 8 memory slots in all: 4 slots are black the other 4 slots are white. I currently have 4 memory modules of 1 GB each in the 4 white slots. That leaves me with 4 free memory slots. My question is: can I put 4 memory modules of 2 GB each in the 4 remaining slots or do I have to use modules of 1 GB all over? FYI here is the output of lshw: alpha description: Ordinateur Tour produit: Precision WorkStation 690 *-cpu:0 description: CPU produit: Intel(R) Xeon(R) CPU X5355 @ 2.66GHz *-memory description: Mémoire Système identifiant matériel: 1000 emplacement: Carte mère taille: 4GiB *-bank:0 description: FB-DIMM DDR2 FB-DIMM Synchrone 667 MHz (1,5 ns) produit: HYMP512F72CP8N3-Y5 fabriquant: Hynix Semiconductor (Hyundai Electronics) identifiant matériel: 0 numéro de série: 56737501 emplacement: DIMM 1 taille: 1GiB bits: 64 bits horloge: 667MHz (1.5ns) *-bank:1 description: FB-DIMM DDR2 FB-DIMM Synchrone 667 MHz (1,5 ns) produit: HYMP512F72CP8N3-Y5 fabriquant: Hynix Semiconductor (Hyundai Electronics) identifiant matériel: 1 numéro de série: 48115124 emplacement: DIMM 2 taille: 1GiB bits: 64 bits horloge: 667MHz (1.5ns) *-bank:2 description: FB-DIMM DDR2 FB-DIMM Synchrone 667 MHz (1,5 ns) produit: HYMP512F72CP8N3-Y5 fabriquant: Hynix Semiconductor (Hyundai Electronics) identifiant matériel: 2 numéro de série: 48115523 emplacement: DIMM 3 taille: 1GiB bits: 64 bits horloge: 667MHz (1.5ns) *-bank:3 description: FB-DIMM DDR2 FB-DIMM Synchrone 667 MHz (1,5 ns) produit: HYMP512F72CP8N3-Y5 fabriquant: Hynix Semiconductor (Hyundai Electronics) identifiant matériel: 3 numéro de série: 48115424 emplacement: DIMM 4 taille: 1GiB bits: 64 bits horloge: 667MHz (1.5ns) *-bank:4 description: FB-DIMM DDR2 FB-DIMM Synchrone 667 MHz (1,5 ns) [vide] fabriquant: FFFFFFFFFFFF identifiant matériel: 4 numéro de série: FFFFFFFF emplacement: DIMM 5 bits: 64 bits horloge: 667MHz (1.5ns) *-bank:5 description: FB-DIMM DDR2 FB-DIMM Synchrone 667 MHz (1,5 ns) [vide] fabriquant: FFFFFFFFFFFF identifiant matériel: 5 numéro de série: FFFFFFFF emplacement: DIMM 6 bits: 64 bits horloge: 667MHz (1.5ns) *-bank:6 description: FB-DIMM DDR2 FB-DIMM Synchrone 667 MHz (1,5 ns) [vide] fabriquant: FFFFFFFFFFFF identifiant matériel: 6 numéro de série: FFFFFFFF emplacement: DIMM 7 bits: 64 bits horloge: 667MHz (1.5ns) *-bank:7 description: FB-DIMM DDR2 FB-DIMM Synchrone 667 MHz (1,5 ns) [vide] fabriquant: FFFFFFFFFFFF identifiant matériel: 7 numéro de série: FFFFFFFF emplacement: DIMM 8 bits: 64 bits horloge: 667MHz (1.5ns) *-pci:0 description: Host bridge produit: 5000X Chipset Memory Controller Hub fabriquant: Intel Corporation identifiant matériel: 100 information bus: pci@0000:00:00.0 version: 12 bits: 32 bits horloge: 33MHz

    Read the article

  • Tri-head linux system with Xmonad: is it possible to have HW acceleration

    - by progo
    What means there exists to have three monitors, all controlled by Xmonad and have hardware 3D acceleration as well? I had the pleasure of using three monitors earlier this year, and while Xmonad and Xinerama handle three monitors easily, I had to throw in an extra display driver, and also let go of Nvidia's own TwinView (which is a hack on Xinerama). This left me with no HW acceleration and some flickering as double buffering wouldn't work with certain applications. However, the three monitors handle so beautifully that I had hard time coming back to two. I understand the easiest way to achieve HW-accelerated tri-head combo is to split into two Xorgs. I wouldn't be able to switch windows between the Xorgs, so I'm not really into this solution. What's more, having a cheap and old PCI card along with even slightly better PCIe seemed to slow things down. Even if I occasionally disabled the third monitor from Xorg configure, I couldn't get HW acceleration to work. Only after I physically disconnected the old PCI card, I could get the games back in business. Would a Matrox Dual/Tri-head2go and a powerful Nvidia GPU do the trick? I understand Xmonad can be configured to "believe" that a "single" (as Dualhead2Go will merge) 3360x1050 display is actually two different ones? So that Xmonad's Mod-w and Mod-e would work properly there.

    Read the article

  • NVIDIA Tesla K20C in Dell PowerEdge R720xd --- power cables

    - by CptSupermrkt
    I am trying to put an NVIDIA Tesla K20C into a Dell PowerEdge R720xd. I'm having a bit of trouble understanding the power requirements of the card. First, here is a picture of two pages of the same manual, which seems contradictory to me. One page says only a single connector is required, while the next page says both are required. The entire manual for the card can be found here: http://www.nvidia.com/content/PDF/kepler/Tesla-K20-Active-BD-06499-001-v02.pdf Here is an photo taken of the power connections on the card: And here is a photo of where those connectors need to go, onto the PCI-E riser of the r720xd: Neither the R720xd NOR the GPU came with the necessary cables. And given what appears to be a contradiction in the GPU manual (above), I'm not even sure at this point what we actually need. I have searched high and low online for things like 2x6 pin PCI-E to 8 pin male-to-male and so on, and for the life of me cannot find what we need. In case anyone needs it, the owner's manual of the R720xd can be found here: ftp://ftp.dell.com/Manuals/all-products/esuprt_ser_stor_net/esuprt_poweredge/poweredge-r720xd_Owner%27s%20Manual_en-us.pdf The relevant page is page 68, which clearly indicates that the 8-pin female port on the riser card is for a GPU. The bottom line question: exactly what power cables do we need to buy, and where can we find them?

    Read the article

  • Network card very slow, only on Windows

    - by J Penguin
    This only happens to 1 of my machine, and only when booting into Windows 7. No matter what network card I put in, Windows would default its mode to 10Mbps full duplex. Transfer speed is approximately 1 MB/s. If I set it to 100Mbps, the transfer drops to 100-200K/s. If I set it to 1000Mbps, the connection is lost completely. I've tried swapping in different cards, both PCI-E and PCI. I'v etried update the windows, I've tried reinstalling the drivers... On this very same machine, if I boot into Fedora, it can use the card at its full capacity 1000Mbps transfering 80+ MB/s And all the cards work just fine when plugging into other machines on the same network. I'm very curious. What could be the reason for this? The only different software that this machine has is virtual box with a VPN emulator, but disabling that VPN doesn't seem to do anything. I would like to get this fixed, hopefully, without reinstalling windows _< Will that be possible?

    Read the article

  • Memory modules not running at rated speeds.

    - by Wesley
    Hi all, I'm having some odd memory issues with my build. Here are my specs right now: QDI Superb 4 motherboard Intel Pentium 4 Northwood 2.4GHz (512KB L2, 533MHz FSB) 3x 256MB PC2100 DDR266 RAM 16MB NVIDIA TNT2 Pro AGP Seagate 80GB IDE HDD Generic USB 2.0 PCI Generic Modem PCI Bestec 250W PSU To be even more specific, here are the current brands and models of each module: Kingston KVR266X64C25/256 Samsung PC2100U-25331-Z SMART SM5643285D4N0CHM0H Supposedly, they are all PC2100 266MHz modules with a latency of 2.5. Looking in Speccy, the Kingston module is somehow running at a speed of PC2300 ~284MHz. I've never overclocked RAM at all as I don't know how to. However, when I first started the computer, I had the SMART module in place first and then reset the BIOS settings, including the integrated overclocking options. However, this still doesn't explain why the Kingston module runs at a higher speed than the SMART and Samsung module. Why is it like this? On a side note, where could I find the motherboard manual for the QDI Superb 4? Thanks in advance.

    Read the article

  • Managing disk in a VM

    - by dst
    I'm replacing my two old rack servers with a new one that has plenty of power to take over the functionality my current servers. The server is a 4U rack mount with 16 3.5" SAS drive bays, two 2.5" bays, a Xeon E3-1230v2 CPU and 32GB of ECC RAM. My issue is the following. I would like to have a FreeBSD file server with ZFS managing disks. However, I need other VMs for e.g. a shell/git server, mail server etc. I'm wondering how to deal with the following issues: I want ZFS to fully manage the disks, so I'm not using any hardware RAID. Should I pass the SAS controller directly to the FreeBSD system as passthrough PCI? I want to maximize the reliability of the setup. On what disks should I install the hypervsor and keep server system disks? For (2) I have the option of having a RAID setup on the SAS controller and using that as system disk to store the hypervisor as well as VM images. However, this makes PCI passthrough to the file server impossible. Another option is using the two 2.5" bays. In terms of reliability how are SSDs compared to e.g. WD RE4 disks? Would it make sense to have two SSDs in software RAID as boot disks for the hypervisor or should I just go with e.g. WD RE4 disks in a software RAID setup. I also need to think about where to store the mails for the mail server, but this could be done over NFS between the VMs. BTW, this is for home use, so the load is not really that big. What I'm looking for is best practices for splitting up a server.

    Read the article

  • RTL8192SU + RTL8191E Linux Issue Installing Driver

    - by s32ialx
    OK I've read tons of fourms of people getting the onboard RTL8191E working and the RTL8192SU working dif is U = USB they are both N and i have both Toshiba L500D-00T pre-installed Win Vistax64-HP and i have obtained the free Win7x64-HP upgrade the onboard wificard sucks and can't hold a stable connection for more then 20minutes in windows but the usb is amazing. Now problem is i tried both Ubuntu and Mandriva with no resolve the issue is the onboard drive detects and actually SHOWS that it's there but no wireless networks detect so it's saying no SSID's are broadcasting which i know is a lie since I'm running a 2wire bell dsl modem with built in wifi and a Linksys wrt54g w/ DD-WRT firmware and both are broadcasting fine. Why don't i use the USB? new in Mandriva Linux Control Center 2010.0 it shows up in Other/Unknown as RTL8191S WLAN Adapter and on the right pane this shows up Identification Vendor: ?Manufacturer Realtek Description: ?RTL8191S WLAN Adapter Media class: ? Connection Bus: ?USB Bus PCI #: ?1 PCI device #: ?5 Vendor ID: ?0x0bda Device ID: ?0x8172 Sub vendor ID: ?0x0000 Sub device ID: ?0x0000 Misc Module: ?rtl819xU In the hardware device manager in mandriva it shows up as unknown but shows that it's realtek and that it's a 8192 chipset. but no option to for a driver install and when i do a make in terminal i get this error and no clue what it means [root@John-PC rtl8192se_linux_2.6.0010.1020.2009_64bit]# make make: *** /lib/modules/2.6.31.12-desktop-3mnb/build: No such file or directory. Stop. make: *** [all] Error 2 [root@John-PC rtl8192se_linux_2.6.0010.1020.2009_64bit]# any help appreciated. and just encase I'm running currently Mandriva Spring 2010 Free

    Read the article

  • Display with intel integrated graphics, bitcoin mine with Radeon 6950

    - by karategeek6
    I'm on Ubuntu Linux 11.04 64 bit. I have an intel i5 with integrated graphics and a Radeon 6950, with one monitor. I would like to run my graphics on the integrated card, and run bitcoin mining on the 6950. I have bitcoin mining working when I use the 6950 for both display and mining. Every time I try and and use the integrated graphics instead, OpenCL doesn't recognize my 6950. Using aticonfig --initial when using the integrated graphics for display breaks things. So I used the xorg.conf it created as a basis and tried to manually edit it. I really don't know what I'm doing, though. My last attempt is given below. The graphics ran off the integrated card, but the 6950 wasn't recognized. Any help would be greatly appreciated! xorg.conf: #Section "ServerLayout" # Identifier "Intel Layout" # Screen "Default Screen" # Identifier "aticonfig Layout" # Screen "aticonfig-Screen[0]-0" # Screen 0 "aticonfig-Screen[0]-0" 0 0 #EndSection Section "Module" Load "glx" EndSection # Intel Section "Device" Identifier "Intel Integrated Graphics" Driver "intel" BusID "PCI:0:2:0" EndSection Section "Monitor" Identifier "Default Monitor" Option "VendorName" "Monitor Vendor" Option "ModelName" "Monitor Name" Option "DPMS" "true" EndSection Section "Screen" Identifier "Default Screen" Device "Intel Integrated Graphics" Monitor "Default Monitor" DefaultDepth 24 EndSection # ATI Section "Device" Identifier "aticonfig-Device[0]-0" Driver "fglrx" BusID "PCI:1:0:0" EndSection Section "Monitor" Identifier "aticonfig-Monitor[0]-0" Option "VendorName" "ATI Proprietary Driver" Option "ModelName" "Generic Autodetecting Monitor" Option "DPMS" "true" EndSection Section "Screen" Identifier "aticonfig-Screen[0]-0" Device "aticonfig-Device[0]-0" Monitor "aticonfig-Monitor[0]-0" DefaultDepth 24 SubSection "Display" Viewport 0 0 Depth 24 EndSubSection EndSection

    Read the article

  • XenServer 5.5 running WHS.. trying to add local or network printer/scanner/copier

    - by ProstheticHead
    Hi guys. Just wondering if anyone has prior experience in sharing a multifunction printer across a (mostly windows) network? My situation at the minute is complicated.. I DID have the printer attached directly to a Windows Home Server box and was able to scan to a share and print across the network from my other computers. Compatibility problems have forced me to virtualize WHS on XenServer 5.5... This is actually quite useful because I can now run other things on the same box, but the problem is that now WHS doesn't get direct hardware access so it doesn't see a USB attached PSC... Grrrr! So now I have a choice to make. I've read somewhere that I can buy an add in PCI USB controller and somehow set up a passthrough to one VM at a time. To me, this sound complicated but if it's likely to work reliably I'd prefer this method. I've read about another approach, which I'm not sure about either, but I guess sounds plausible. A Network USB server, (NOT a print server) that can somehow make a USB port accessible across a network. My worry here is that it likely needs some kind of 3rd party software to work.. so not ideal. If there are any other methods you can suggest I'd be happy to hear them... I need your help guys. I'm also in the market for a PCI express SATA controller, nothing flashy, just need up to 8 ports, JBOD and 100% compatability.. Any suggestions? Regards Kevin

    Read the article

  • GUI interfaces to ATI card behave weirdly out of the box and after updates.

    - by jdk
    My Lenovo W500 came with an ATI Mobility FireGL V5700 and both the Catalyst control center software and Vista display manager display four monitors. What's really annoying is the behaviour. My two active displays (laptop display + my external monitor) are always #s 3 and 4 respectively which doesn't make sense. This is out of the box. Additionally dragging & dropping is jumpy and displays #1 and 2 (always inactive because they don't exist to the software) are often preventing me from dragging #3 and 4 to the rightmost side. They also auto-snap to weird positions and certain sensible positions like position one directly over top of the other are not possible. The exact same annoyances are present when using the Windows Display manager too. In other words the interface is crap and I'm looking for a fix that's not wishing I had gone with nVidia instead. I've updated drivers, and Catalyst control centre. Have latest Windows and AMD/ATI updates. Any thoughts? Graphics Software Driver Packaging Version 8.563.2.1-090401a-079160C-Lenovo Provider ATI Technologies Inc. 2D Driver Version 7.01.01.849 2D Driver File Path /REGISTRY/MACHINE/SYSTEM/ControlSet001/Control/Class/{4D36E968-E325-11CE-BFC1-08002BE10318}/0001 Direct3D Version 7.14.10.0630 OpenGL Version 6.14.10.8306 Catalyst® Control Center Version 2009.0401.1328.22301 Graphics Hardware Primary Adapter Graphics Card Manufacturer Powered by ATI Graphics Chipset ATI Mobility FireGL V5700 Device ID 9591 Vendor 1002 Subsystem ID 2126 Subsystem Vendor ID 17AA Graphics Bus Capability PCI Express 2.0 Maximum Bus Setting PCI Express 2.0 x16 BIOS Version 010.088.000.021 BIOS Part Number BK-ATI VER010.088.000.021.034663 BIOS Date 2009/09/30 Memory Size 512 MB Memory Type DDR3 Core Clock in MHz 600 MHz Memory Clock in MHz 700 MHz

    Read the article

  • VMWare ESXi 5 - Expanded RAID 5 array - cannot access datastore

    - by Dayton Brown
    I'm using VMWare ESXi 5 and had a 2 TB RAID 5 setup on an HP DL360 with a P400i RAID card. I added two more 1 TB drives and using the SmartStart ACU, added the drives and expanded the logical disk. Now after booting back to ESXi, the server boots, but lists no available persistent storage. I've rescanned multiple times to no avail: the Datastore doesn't show up. I booted to GParted and the 1.8TB partition shows up, but it shows as unknown. Anyone have any good ideas? EDIT: Final Solution So after much gnashing of teeth, it was fairly simple to solve. I purchased an eSata 2 TB external drive and a PCI eSata card for my server. I then used Clonezilla to image the current partitions to my new external drive. You have to check "don't check drive sizes" in advanced mode, otherwise it will yell at you for have a smaller drive. For some reason my PCI card wouldn't boot on my HP server, so I hooked the drive up to another desktop I had, booted to VMWare, and copied the vmdk's to another drive. I'm going to blow out the RAID config and then create 1.5TB logical drives.

    Read the article

  • Windows Server 2008 - RAID 5 Fails on Reboot

    - by Adam
    Hey, I've got an install of Windows Server 2008 Enterprise. It's running software RAID-5 with five disks. The disks were originally formatted under Windows Server 2003, but came up fine once I installed Windows Server 2008. The issue I'm having is that every time I reboot the server, the RAID comes up with a "Failed Redundancy" - the data stays available. I have 4 disks on a PCI SATA controller, and one of the disks connected to the motherboard's on-board SATA ports. (The other on-board port has the system disk connected.) I was having Disk #4 fail consistently, so I tried swapping the cables on the controller end. I swapped the on-board RAID disk with one on the PCI controller. Same issue now, expect with disk #1. Once the system's up, I can reactivate the RAID, it will resync for a while, then go to "Healthy", and will stay that way for an indefinite amount of time - until I reboot. As soon as I reboot, the disk drops again. I've ruled out disk + cable with the recabling. I don't believe it would be the controller as it seems to work fine most of the time - only failing on reboot, and the other port on the same controller connects the system disk - which is clearly working. I did look in the event log, but didn't see anything particularly relevant (although I didn't know what I was looking for - just looked for anything with a "Warning" or "Error" symbol that looked disk-related :)). I'm not particularly familiar with RAID on Windows, does anyone have any idea why this might be doing this? Any idea how to fix it? Any suggestions appreciated! -- Adam

    Read the article

  • Doesn't VirtualBox 4.0 support drag-drop file copy yet?

    - by Benjamin
    Version 4.0.0 will be new major release. The following major new features were added: -New settings/disk file layout for VM portability; see the manual for more information. -Open Virtualization Format Archive (OVA) support; see the manual for more information. -VMM: support more than 1.5/2 GB guest RAM on 32-bit hosts -Language bindings: uniform Java bindings for both local (COM/XPCOM) and remote (SOAP) -invocation APIs -Chipset: added support for the Intel ICH9 chipset with 3 PCI buses, PCI express and -Message Signaled Interrupts (MSI) -Audio: Intel HD Audio is now available as guest hardware, for better support with modern -guest operating systems (e.g. 64-bit Windows; bug #2785). -GUI: redesigned user interface with guest window preview -GUI: new display mode with downscaled guest display -Resource control: added support for limiting a VM's CPU time and IO bandwidth. -Storage: support asynchronous I/O for iSCSI, VMDK, VHD and Parallels images -Storage: support for resizing VDI and VHD images -Windows Additions: support for automatically updating the Guest Additions (requires -installed Windows Guest Additions 4.0 or later) -Guest Additions: support for copying files into the guest file system What does the last line mean? I thought this is a drag-drop file copy feature like VMWare. I tried that. But I couldn't copy by drag-drop, ctrl-c ctrl-v either. Edit: I mean VBox 4.0 beta, not 3.x The release note is here. Download link is here.

    Read the article

  • Short, intermittent USB port timeouts

    - by jacobsee
    I have a data acquisition application controlled by a Windows PC. I am using an Intel Desktop Board DH67CL motherboard. This has 6 USB2 ports along with 2 of the new blue USB3 ports. The DAQ instrument connects via USB to the computer. Roughly once every day or two there is a short communication glitch with the USB that causes the instrument to disconnect briefly and then reconnect. This is logged so I know whenever it happens. Occasionally it will cause the data acquisition to stop. I've verified that the glitches will go away if I use the USB3 ports, or if I use a PCI add-on card with USB ports. So it seems that there is something going on with these built-in USB2 ports on this motherboard. I haven't yet had a chance to test with other motherboards. My question: what could be causing these glitches and how to get rid of them for this board, or is there a better motherboard to use? We have standardized on the DH67CL because it's inexpensive, has 3 PCI slots that we need, and is readily available. We don't need the power of higher-end server boards but reliability is important. Thanks. Update: This problem has been reproduced many times on different hardware, though we always use the same model of motherboard (DH67CL) and power supply (Antec EA-430D). I don't think the power requirements are very high but will check on that.

    Read the article

  • xen + debian network after upgrade squeeze to wheeze

    - by rush
    I've got a Debian + Xen server. After a system upgrade to the stable version the network doesn't come up after boot. Every time after reboot I need to bring it up manually. The network configuration was not changed during upgrade. Here is /etc/network/interfaces: auto lo iface lo inet loopback auto eth0 iface eth0 inet static address 11.22.33.44 netmask 255.255.255.0 gateway 11.22.33.1 nameserver 8.8.8.8 After boot ip r shows no route and eth0 has no ip address. Manually ip and route setup goes fine and network starts working. Messages from dmesg about network I've found (looks like nothing interesting) [ 3.894401] ACPI: Fan [FAN3] (off) [ 3.894444] ACPI: Fan [FAN4] (off) [ 4.178348] e1000e 0000:00:19.0: eth0: (PCI Express:2.5GT/s:Width x1) 00:1e:67:14:66:c9 [ 4.178351] e1000e 0000:00:19.0: eth0: Intel(R) PRO/1000 Network Connection [ 4.178392] e1000e 0000:00:19.0: eth0: MAC: 10, PHY: 11, PBA No: 0100FF-0FF [ 4.178413] e1000e 0000:02:00.0: Disabling ASPM L0s L1 [ 4.178432] xen: registering gsi 16 triggering 0 polarity 1 -- [ 4.223667] ata5: DUMMY [ 4.223668] ata6: DUMMY [ 4.289153] e1000e 0000:02:00.0: eth1: (PCI Express:2.5GT/s:Width x1) 00:1e:67:14:66:c8 [ 4.289155] e1000e 0000:02:00.0: eth1: Intel(R) PRO/1000 Network Connection [ 4.289245] e1000e 0000:02:00.0: eth1: MAC: 3, PHY: 8, PBA No: 1000FF-0FF [ 4.506908] usb 1-1: new high-speed USB device number 2 using ehci_hcd [ 4.542920] ata2: SATA link up 3.0 Gbps (SStatus 123 SControl 300) -- [ 10.362999] EXT4-fs (dm-23): mounted filesystem with ordered data mode. Opts: (null) [ 10.419103] EXT4-fs (dm-3): mounted filesystem with ordered data mode. Opts: (null) [ 10.988255] ADDRCONF(NETDEV_UP): eth1: link is not ready [ 13.175533] Event-channel device installed. [ 13.287555] XENBUS: Unable to read cpu state -- [ 13.288670] XENBUS: Unable to read cpu state [ 13.965939] Bridge firewalling registered [ 14.134048] e1000e: eth1 NIC Link is Up 1000 Mbps Full Duplex, Flow Control: Rx/Tx [ 14.283862] ADDRCONF(NETDEV_UP): peth0: link is not ready [ 14.284543] ADDRCONF(NETDEV_CHANGE): eth1: link becomes ready [ 17.800627] e1000e: peth0 NIC Link is Up 1000 Mbps Full Duplex, Flow Control: Rx/Tx [ 17.801377] ADDRCONF(NETDEV_CHANGE): peth0: link becomes ready [ 18.307278] device peth0 entered promiscuous mode [ 24.538899] eth1: no IPv6 routers present [ 28.570902] peth0: no IPv6 routers present I've upgraded two servers and I've such behaviour on two of them. How to fix this and get network starts automatically on boot?

    Read the article

  • computer freezes but music continues

    - by Danny
    Recently I have had a problem where my computer will freeze completely but if I happen to be streaming Pandora in a tab that will continue playing. If I wait about 2-5 minutes it will eventually come back and start working normally. I also noticed that during the period that it is unresponsive that the HDD activity light stays lit the whole time, not flashing. I've ran memtest86+ and a diagnostic from Western Digital for my HDD model and none of them reported any errors. The specs for my computer are 1 x ASRock H55M/USB3 R2.0 LGA 1156 Intel H55 HDMI USB 3.0 Micro ATX Intel Motherboard 1 x CORSAIR Enthusiast Series CMPSU-550VX 550W ATX12V V2.2 SLI Ready CrossFire Ready 80 PLUS Certified Active PFC Compatible with Core i7 Power Supply 1 x Intel Core i3-540 Clarkdale 3.06GHz LGA 1156 73W Dual-Core Desktop Processor Intel HD Graphics BX80616I3540 1 x G.SKILL 4GB (2 x 2GB) 240-Pin DDR3 SDRAM DDR3 1600 (PC3 12800) Dual Channel Kit Desktop Memory Model F3-12800CL9D-4GBNQ 1 x ASUS PCE-N13 PCI Express 150/300Mbps Transfer/Receive Rate Wireless Adapter 1 x EVGA 01G-P3-1556-KR GeForce GTX 550 Ti (Fermi) FPB 1GB 192-bit GDDR5 PCI Express 2.0 x16 HDCP Ready SLI Support Video Card I can't imagine what would be causing these problems.

    Read the article

  • How to write rules for persistent net names?

    - by ndemou
    I know that a process generates persistent network card names based on rules found in /lib/udev/rules.d/75-persistent-net-generator.rules. I also know how to completely disable this process with a simple echo '#' > /etc/udev/rules.d/75-persistent-net-generator.rules but I've read that I "could also write my own rules file to give the interface a name — the persistent rules generator ignores the interface if a name has already been set" (/etc/udev/rules.d/README confirms that this is possible). Do you have any pointers to documentation about how to write such rules? (I mostly care about Debian/Ubuntu and a bit less for CentOS) As a specific example of why I want to write custom rules: I have two identical servers with one onboard LAN and one PCI LAN. In case of HW failure I want to be able to move disks from HW#1 to HW#2 and it's important for eth0 to continue pointing to the onboard card and eth1 to the PCI card (no one wants to mess with cabling in the middle of a HW failure panic). My current workaround works but is a lot of work[1] so I wonder if writing custom rules would allow me to express something simple like this: cards with MAC A or B should be named eth0 cards with MAC C or D should be named eth1 follow default naming scheme for anything else [1] install the OS in HW#1 and keep a copy of /etc/udev/rules.d/70-persistent-net.rules. Move the disks to HW#2 and keep a second copy of the same file. Concatenate the two copies and manually edit the NAME="ethX" part. Replace /etc/udev/rules.d/70-persistent-net.rules with my version. Finally disable auto-creation of a new 70-persistent-net.rules using echo '#' > /etc/udev/rules.d/75-persistent-net-generator.rules

    Read the article

  • Comparing 128MB GeForce 8600GT and 512MB Radeon X1650

    - by Synetech inc.
    Hi, I'm trying to determine which is the better of these two video cards: 128MB Nvidia GeForce 8600GT card while the other has a 512MB ATI Radeon X1650 card. Both cards are the upper-level mid-range versions of their respective series. On the one hand, the ATI has substantially more VRAM, but the Nvidia supports D3D 10 and SM4.0 as opposed to D3D 9.0c/SM3.0 that the ATI supports. Also, I have always heard better things about Nvidia cards compared to ATI cards. I'm trying to find some advice on which one is better, but I can't find any actual comparisons or anything for these specific cards (the comparisons I can find are only similar ones like the X1650 Pro or 8600GT PCI-E), so I figure that what I need to know is whether the extra VRAM is that important. Looking at the ATI table and the Nvidia table seems to indicate that the Nvidia is better, but then again, the Nvidia table also says that the GeForce 8600GT is a PCI-E card with at least 256MB even though the card in question is an AGP with 128MB. (:-?) (It looks like the ATI card is not supported in Windows 7 while the Nvidia card is, which I suppose is also a factor, though not quite as immediately relevant as performance.) Any ideas? Thanks a lot.

    Read the article

  • Diagnosing PC crashes (most often while using shared folders or torrents)

    - by Dyppl
    For the last few weeks my PC (pretty old P4 with WinXP SP3) has been crashing randomly. It just suddenly reboots instanteneously. It feels hardware-related but I wasn't able to determine wether it's software or hardware that causes it. I did notice a pattern though: it's more likely to crash when I copy a lot of files over network or have uTorrent running, but sometimes it crashes when I am not doing anything with it. Copying files from it over network causes it to crash in 1 to 10 minutes almost every time. Using torrents causes it to crash every 1-3 hours. With neither or that on it crashes every 24 hours or so. I ruled out the following probable causes: PSU (I bought a new one and turned off most of the drives so the power is sufficient 100%) Bad HDD or interface cable on my SATA disk from which I was originally copying the data over network (bought new SATA cable and later yanked out the HDD completely, PC still crashes without it) Video adapter (AGP slot is now empty, using the onboard VGA at the moment) Network adapter (removed it from PCI, using onboard LAN) CPU (I think: I changed the termopaste and it's temperature is below 50C) RAM (I think: I ran Memtest86 and it didn't show any errors) At the moment I only have only one system HDD and DVD drives, a mouse and a keyboard plugged in. The fact that it crashes most often when I use network extensively makes me think that maybe it's software related (I removed the network adapter from PCI and now am using an onboard one, so network hardware is unlikely to cause problems). I am now pondering system reinstall but it's not a pleasant solution so I decided to ask wether there are better ideas first. If someone can share a good diagnostic tool it would be great because I didn't find anything good. Thanks in advance, I hope that "help to diagnose" questions aren't entirely banned here. EDIT: Motherboard is actually ~4 years old as I replaced it back in 2007

    Read the article

  • My linux server takes more than an hour to boot. Suggestions?

    - by jamieb
    I am building a CentOS 5.4 system that boots off a compact flash card using a card reader that emulates an IDE drive. It literally takes about an hour to boot. The ultra-slow part occurs when Grub is loading the kernel. Once that's done, the rest of the boot process only takes about a minute to get to a login prompt. Does anyone have any suggestions? I suspect that it may have to do with UDMA. Everything IDE-related in my BIOS seems to checkout. The read performance hdparm is telling me 1.77 MB/s. Ouch! (But even at that rate, it still shouldn't take an hour to decompress and load the kernel) [root@server ~]# hdparm -tT /dev/hdc /dev/hdc: Timing cached reads: 2444 MB in 2.00 seconds = 1222.04 MB/sec Timing buffered disk reads: 6 MB in 3.39 seconds = 1.77 MB/sec Trying to enable DMA is a no-go though: [root@server ~]# hdparm -d1 /dev/hdc /dev/hdc: setting using_dma to 1 (on) HDIO_SET_DMA failed: Operation not permitted using_dma = 0 (off) Here's some command outputs that might help: System [root@server ~]# uname -a Linux server.localdomain 2.6.18-164.el5xen #1 SMP Thu Sep 3 04:47:32 EDT 2009 i686 i686 i386 GNU/Linux PCI info: [root@server ~]# lspci -v 00:00.0 Host bridge: Intel Corporation 82945G/GZ/P/PL Memory Controller Hub (rev 02) Subsystem: Intel Corporation 82945G/GZ/P/PL Memory Controller Hub Flags: bus master, fast devsel, latency 0 Capabilities: [e0] Vendor Specific Information 00:02.0 VGA compatible controller: Intel Corporation 82945G/GZ Integrated Graphics Controller (rev 02) (prog-if 00 [VGA controller]) Subsystem: Intel Corporation 82945G/GZ Integrated Graphics Controller Flags: bus master, fast devsel, latency 0, IRQ 10 Memory at fdf00000 (32-bit, non-prefetchable) [size=512K] I/O ports at ff00 [size=8] Memory at d0000000 (32-bit, prefetchable) [size=256M] Memory at fdf80000 (32-bit, non-prefetchable) [size=256K] Capabilities: [90] Message Signalled Interrupts: 64bit- Queue=0/0 Enable- Capabilities: [d0] Power Management version 2 00:1d.0 USB Controller: Intel Corporation 82801G (ICH7 Family) USB UHCI Controller #1 (rev 01) (prog-if 00 [UHCI]) Subsystem: Intel Corporation 82801G (ICH7 Family) USB UHCI Controller #1 Flags: bus master, medium devsel, latency 0, IRQ 16 I/O ports at fe00 [size=32] 00:1d.1 USB Controller: Intel Corporation 82801G (ICH7 Family) USB UHCI Controller #2 (rev 01) (prog-if 00 [UHCI]) Subsystem: Intel Corporation 82801G (ICH7 Family) USB UHCI Controller #2 Flags: bus master, medium devsel, latency 0, IRQ 17 I/O ports at fd00 [size=32] 00:1d.2 USB Controller: Intel Corporation 82801G (ICH7 Family) USB UHCI Controller #3 (rev 01) (prog-if 00 [UHCI]) Subsystem: Intel Corporation 82801G (ICH7 Family) USB UHCI Controller #3 Flags: bus master, medium devsel, latency 0, IRQ 18 I/O ports at fc00 [size=32] 00:1d.3 USB Controller: Intel Corporation 82801G (ICH7 Family) USB UHCI Controller #4 (rev 01) (prog-if 00 [UHCI]) Subsystem: Intel Corporation 82801G (ICH7 Family) USB UHCI Controller #4 Flags: bus master, medium devsel, latency 0, IRQ 19 I/O ports at fb00 [size=32] 00:1d.7 USB Controller: Intel Corporation 82801G (ICH7 Family) USB2 EHCI Controller (rev 01) (prog-if 20 [EHCI]) Subsystem: Intel Corporation 82801G (ICH7 Family) USB2 EHCI Controller Flags: bus master, medium devsel, latency 0, IRQ 16 Memory at fdfff000 (32-bit, non-prefetchable) [size=1K] Capabilities: [50] Power Management version 2 Capabilities: [58] Debug port 00:1e.0 PCI bridge: Intel Corporation 82801 PCI Bridge (rev e1) (prog-if 01 [Subtractive decode]) Flags: bus master, fast devsel, latency 0 Bus: primary=00, secondary=01, subordinate=01, sec-latency=32 I/O behind bridge: 0000d000-0000dfff Memory behind bridge: fde00000-fdefffff Prefetchable memory behind bridge: 00000000fdd00000-00000000fdd00000 Capabilities: [50] #0d [0000] 00:1f.0 ISA bridge: Intel Corporation 82801GB/GR (ICH7 Family) LPC Interface Bridge (rev 01) Subsystem: Intel Corporation 82801GB/GR (ICH7 Family) LPC Interface Bridge Flags: bus master, medium devsel, latency 0 Capabilities: [e0] Vendor Specific Information 00:1f.2 IDE interface: Intel Corporation 82801GB/GR/GH (ICH7 Family) SATA IDE Controller (rev 01) (prog-if 80 [Master]) Subsystem: Intel Corporation 82801GB/GR/GH (ICH7 Family) SATA IDE Controller Flags: bus master, 66MHz, medium devsel, latency 0, IRQ 17 I/O ports at <unassigned> I/O ports at <unassigned> I/O ports at <unassigned> I/O ports at <unassigned> I/O ports at f800 [size=16] Capabilities: [70] Power Management version 2 00:1f.3 SMBus: Intel Corporation 82801G (ICH7 Family) SMBus Controller (rev 01) Subsystem: Intel Corporation 82801G (ICH7 Family) SMBus Controller Flags: medium devsel, IRQ 17 I/O ports at 0500 [size=32] 01:04.0 Ethernet controller: Realtek Semiconductor Co., Ltd. RTL-8139/8139C/8139C+ (rev 10) Subsystem: Realtek Semiconductor Co., Ltd. RTL-8139/8139C/8139C+ Flags: bus master, medium devsel, latency 32, IRQ 18 I/O ports at de00 [size=256] Memory at fdeff000 (32-bit, non-prefetchable) [size=256] Capabilities: [50] Power Management version 2 01:06.0 Ethernet controller: Realtek Semiconductor Co., Ltd. RTL-8139/8139C/8139C+ (rev 10) Subsystem: Realtek Semiconductor Co., Ltd. RTL-8139/8139C/8139C+ Flags: bus master, medium devsel, latency 32, IRQ 17 I/O ports at dc00 [size=256] Memory at fdefe000 (32-bit, non-prefetchable) [size=256] Capabilities: [50] Power Management version 2 01:07.0 Ethernet controller: Realtek Semiconductor Co., Ltd. RTL-8139/8139C/8139C+ (rev 10) Subsystem: Realtek Semiconductor Co., Ltd. RTL-8139/8139C/8139C+ Flags: bus master, medium devsel, latency 32, IRQ 19 I/O ports at da00 [size=256] Memory at fdefd000 (32-bit, non-prefetchable) [size=256] Capabilities: [50] Power Management version 2 hdparm ouput: [root@server ~]# hdparm /dev/hdc /dev/hdc: multcount = 0 (off) IO_support = 0 (default 16-bit) unmaskirq = 0 (off) using_dma = 0 (off) keepsettings = 0 (off) readonly = 0 (off) readahead = 256 (on) geometry = 8146/16/63, sectors = 8211168, start = 0 [root@server ~]# hdparm -I /dev/hdc /dev/hdc: ATA device, with non-removable media Model Number: InnoDisk Corp. - iCF4000 4GB Serial Number: 20091023AACA70000753 Firmware Revision: 081107 Standards: Supported: 5 Likely used: 6 Configuration: Logical max current cylinders 8146 8146 heads 16 16 sectors/track 63 63 -- CHS current addressable sectors: 8211168 LBA user addressable sectors: 8211168 device size with M = 1024*1024: 4009 MBytes device size with M = 1000*1000: 4204 MBytes (4 GB) Capabilities: LBA, IORDY(can be disabled) Standby timer values: spec'd by Vendor R/W multiple sector transfer: Max = 2 Current = 2 DMA: mdma0 mdma1 mdma2 udma0 udma1 *udma2 udma3 udma4 Cycle time: min=120ns recommended=120ns PIO: pio0 pio1 pio2 pio3 pio4 Cycle time: no flow control=120ns IORDY flow control=120ns Commands/features: Enabled Supported: * Power Management feature set * WRITE_BUFFER command * READ_BUFFER command * NOP cmd * CFA feature set * Mandatory FLUSH_CACHE HW reset results: CBLID- above Vih Device num = 0 CFA power mode 1: enabled and required by some commands Maximum current = 100ma Checksum: correct

    Read the article

  • Wireless internet connection connects but internet does not work (no packets received). Wired does.

    - by Rodney
    When I connect my PC via ethernet cable to my ADSL router it works fine. When I connect via Wireless it connects and the internet will work for a random amount of time and then stop working. It stays connected with a strong signal but no packets are received. My laptop/iphone are right next to it and wireless works fine. If I open the Wireless USB status, it says it is connected to my SSID with full strength (54 mps - I am 3 meteres away from my router) and the activty shows as Packets 594 SENT and 105 RECEIVED (this goes up VERY slowly) I have tried the following: Turned off anitvirus and firewall completely. Tested the wifi signal- I am writing this on my laptop which is next to my PC and also has full wifi strength. Tried a different wireless adapter - I dug out an old PCI wireless card - it does the exact same thing. Compared all wireless settings to my laptop. I can ping google.com and it replies (sometimes with packet loss) When I reboot the PC it will connect for a minute or two (random time) and then just stops again. I tried Firefox, IE etc. no joy I have updated all latest versions (Netgear WG111v2) and drivers Checked Event Log - nothing unusual Ping the router (and even connect as admin for the few minutes when the internet does work) Changed the MTU down to 1200 using DrTCP Checked Device Manager for conflicts - none. I ping the router from the PC (192.168.0.10 - 192.168.0.1) and it replies with 4 packets. BUT, on my router admin page (which I access via http on my laptop wirelessly) - if I ping 192.168.0.10 all packets timeout (pinging my laptop 192.168.0.12 works fine) My router admin page shows the leased IP address for 192.168.0.10 (ie it is definitely talking to the router initially) Now I am out of ideas - please help. I think it is an OS/Software issue as I have tried 2 different wireless adapaters (PCI and USB) with the same result but all other wireless devices work fine around mine). It's not the firewall. It is getting assigned an IP address correctly (my PC gets 192.168.0.10, my laptop is .12) It is assigned by DHCP. As soon as I plug in the ethernet cable it all works fine. Repairing the adapter sometimes helps but it will always stop working after a random time. The wireless adapter always shows as connected with Excellent signal but the internet does not work. I am running Windows XP SP3 and have tried a Netgear WG111v2 USB adapter. Thanks in advance! UPDATE: The internet seems to be working, it is just either sending packets too small or slow to work (some small pages load bits of them very slowly but then hang). XP seems to have a networking diagnostic app - here is the output: Last diagnostic run time: 08/30/10 08:16:38 IP Configuration Diagnostic Invalid IP address info Valid IP address detected: 192.168.0.10 IP Layer Diagnostic Corrupted IP routing table info The default route is valid info The loopback route is valid info The local host route is valid info The local subnet route is valid Invalid ARP cache entries action The ARP cache has been flushed Gateway Diagnostic Gateway info The following proxy configuration is being used by IE: Automatically Detect Settings:Disabled Automatic Configuration Script: Proxy Server: Proxy Bypass list: info This computer has the following default gateway entry(ies): 192.168.0.1 info This computer has the following IP address(es): 192.168.0.10 info The default gateway is in the same subnet as this computer info The default gateway entry is a valid unicast address info The default gateway address was resolved via ARP in 1 try(ies) info The default gateway was reached via ICMP Ping in 1 try(ies) info TCP port 80 on host 65.55.12.249 was successfully reached info The Internet host www.microsoft.com was successfully reached info The default gateway is OK DNS Client Diagnostic DNS - Not a home user scenario info Using Web Proxy: no info Resolving name ok for (www.microsoft.com): yes No DNS servers DNS failure HTTP, HTTPS, FTP Diagnostic HTTP, HTTPS, FTP connectivity info FTP (Passive): Successfully connected to ftp.microsoft.com. info HTTP: Successfully connected to www.microsoft.com. warn HTTPS: Error 12002 connecting to www.microsoft.com: The operation timed out warn HTTPS: Error 12002 connecting to www.passport.net: The operation timed out error Could not make an HTTPS connection. info Redirecting user to support call WinSock Diagnostic WinSock status info All base service provider entries are present in the Winsock catalog. info The Winsock Service provider chains are valid. info Provider entry MSAFD Tcpip [TCP/IP] passed the loopback communication test. info Provider entry MSAFD Tcpip [UDP/IP] passed the loopback communication test. info Provider entry RSVP UDP Service Provider passed the loopback communication test. info Provider entry RSVP TCP Service Provider passed the loopback communication test. info Connectivity is valid for all Winsock service providers. Wireless Diagnostic Wireless - Service disabled Wireless - User SSID action User input required: Specify network name or SSID Wireless - First time setup info The Wireless Network name (SSID) to which the user would like to connect = RodSof Wifi. Wireless - Radio off info Valid IP address detected: 192.168.0.10 Wireless - Out of range Wireless - Hardware issue Wireless - Novice user Wireless - Ad-hoc network Wireless - Less preferred Wireless - 802.1x enabled Wireless - Configuration mismatch Wireless - Low SNR Network Adapter Diagnostic Network location detection info Using home Internet connection Network adapter identification info Network connection: Name=Local Area Connection 2, Device=Realtek RTL8168C(P)/8111C(P) PCI-E Gigabit Ethernet NIC, MediaType=LAN, SubMediaType=LAN info Network connection: Name=Wireless USB, Device=NETGEAR WG111v2 54Mbps Wireless USB 2.0 Adapter, MediaType=LAN, SubMediaType=WIRELESS info Both Ethernet and Wireless connections available, prompting user for selection action User input required: Select network connection info Wireless connection selected Network adapter status info Network connection status: Connected HTTP, HTTPS, FTP Diagnostic HTTP, HTTPS, FTP connectivity info FTP (Active): Successfully connected to ftp.microsoft.com. warn HTTP: Error 12007 connecting to www.microsoft.com: The server name or address could not be resolved warn HTTP: Error 12002 connecting to www.hotmail.com: The operation timed out warn HTTPS: Error 12002 connecting to www.passport.net: The operation timed out warn HTTPS: Error 12002 connecting to www.microsoft.com: The operation timed out error Could not make an HTTP connection. error Could not make an HTTPS connection.

    Read the article

  • Why are my USB 2.0 devices crashing Windows XP?

    - by BenAlabaster
    Background on the machine I'm having a problem with: The machine was inherited and appears to be circa 2003 (there's a date stamp on the power supply which leads me to this conclusion). I've got it set up as a Skype terminal for my 2 year old to keep in touch with her grandparents and other members of the family - which everyone loves. It has a generic ATX motherboard with no identifying markings other than one stamp that says "Rev.B". CPU-Z identifies the motherboard model as VT8601 but doesn't provide me with any manufacturer name. On board it has 1 x 10/100 LAN, 2 x USB 1.0, VGA, PS/2 for KB and mouse, parallel port, 2 x serial ports, 2 x IDE, 1 x floppy, 2 x SDRAM slots, 1 x CPU housing that is seating a 1.3GHz Intel Celeron CPU, 3 x PCI, 1 x AGP - although you can only use 2 of the PCI slots if you use the AGP slot due to the physical layout of the board. It's got 768Mb PC133 SDRAM - 1 x 512Mb & 1 x 256Mb installed as well as a D-LINK WDA-2320 54G Wi-Fi network card and a generic USB 2.0 expansion board containing 3 x external + 1 x internal USB connectors. It has a DVD+/-RW running as master on IDE1 and a 1.44Mb 3.5" floppy drive connected to the floppy connector. It has an 80Gb Western Digital hard drive running as master on IDE0. All this is sitting in a slimline case. I don't know the wattage of the PSU, but can post this later if this proves to be helpful. The motherboard is running a version of Award BIOS for which I don't have the version number to hand but can again post this later if it would be helpful. The hard disk is freshly formatted and built with Windows XP Professional/Service Pack 3 and is up to date with all current patches. In addition to Windows XP, the only other software it's running is Skype 4.1 (4.2 hangs the whole machine as soon as it starts up, requiring a hard boot to recover). It's got a Daytek MV150 15" touch screen hooked up to the on board VGA and COM1 sockets with the most current drivers from the Daytek website and the most current version of ELO-Touchsystems drivers for the touch component. The webcam is a Logitech Webcam C200 with the latest drivers from the Logitech website. The problem: If I hook any devices to the USB 2.0 sockets, it hangs the whole machine and I have to hard boot it to get it back up. If I have any devices attached to the USB 2.0 sockets when I boot up, it hangs before Windows gets to the login prompt and I have to hard boot it to recover. Workarounds found: I can plug the same devices into the on board USB 1.0 sockets and everything works fine, albeit at reduced performance. I've tried 3 different kinds of USB thumb drives, 3 different makes/models of webcams and my iPhone all with the same effect. They're recognized and don't hang the machine when I hook them to the USB 1.0 but if I hook them to the USB 2.0 ports, the machine hangs within a couple of seconds of recognizing the devices were connected. Attempted solutions: I've seen suggestions that this could be a power problem - that the PSU just doesn't have the wattage to drive these ports. While I'm doubtful this is the problem [after all the motherboard has the same standard connector regardless of the PSU wattage], I tried disabling all the on board devices that I'm not using - on board LAN, the second COM port, the AGP connector etc. through the BIOS in what I'm sure is a futile attempt to reduce the power consumption... I also modified the ACPI and power management settings. It didn't have any noticeable affect, although it didn't do any harm either. Could the wattage of the PSU really cause this problem? If it can, is there anything I need to be aware of when replacing it or do I just need to make sure it's got a higher wattage than the current one? My interpretation was that the wattage only affected the number of drives you could hook up to the power connectors, is that right? I've installed the USB card in another machine and it works without issue, so it's not a problem with the USB card itself, and Windows says the card is installed and working correctly... right up until I connect a device to it. The only thing I haven't done which I only just thought of while writing this essay is trying the USB 2.0 card in a different PCI slot, or re-ordering the wi-fi and USB cards in the slots... although I'm not sure if this will make any difference - does anyone have any experience that would suggest this might work? Other thoughts/questions: Perhaps this is an incompatibility between the USB 2.0 card and the BIOS, would re-flashing the BIOS with a newer version help? Do I need to be able to identify the manufacturer of the motherboard in order to be able to find a BIOS edition specific for this motherboard or will any version of Award BIOS function in its place? Question: Does anyone have any ideas that could help me get my USB 2.0 devices hooked up to this machine?

    Read the article

  • Why are my USB 2.0 devices hanging Windows XP?

    - by BenAlabaster
    Background on the machine I'm having a problem with: The machine was inherited and appears to be circa 2003 (there's a date stamp on the power supply which leads me to this conclusion). I've got it set up as a Skype terminal for my 2 year old to keep in touch with her grandparents and other members of the family - which everyone loves. It has a generic ATX motherboard with no identifying markings other than one stamp that says "Rev.B". CPU-Z identifies the motherboard model as VT8601 but doesn't provide me with any manufacturer name. On board it has 1 x 10/100 LAN, 2 x USB 1.0, VGA, PS/2 for KB and mouse, parallel port, 2 x serial ports, 2 x IDE, 1 x floppy, 2 x SDRAM slots, 1 x CPU housing that is seating a 1.3GHz Intel Celeron CPU, 3 x PCI, 1 x AGP - although you can only use 2 of the PCI slots if you use the AGP slot due to the physical layout of the board. It's got 768Mb PC133 SDRAM - 1 x 512Mb & 1 x 256Mb installed as well as a D-LINK WDA-2320 54G Wi-Fi network card and a generic USB 2.0 expansion board containing 3 x external + 1 x internal USB connectors - it has a NEC uPD720102 chipset. It has a DVD+/-RW running as master on IDE1 and a 1.44Mb 3.5" floppy drive connected to the floppy connector. It has an 80Gb Western Digital hard drive running as master on IDE0. All this is sitting in a slimline case. I don't know the wattage of the PSU, but can post this later if this proves to be helpful. The motherboard is running a version of Award BIOS for which I don't have the version number to hand but can again post this later if it would be helpful. The hard disk is freshly formatted and built with Windows XP Professional/Service Pack 3 and is up to date with all current patches. In addition to Windows XP, the only other software it's running is Skype 4.1 (4.2 hangs the whole machine as soon as it starts up, requiring a hard boot to recover). It's got a Daytek MV150 15" touch screen hooked up to the on board VGA and COM1 sockets with the most current drivers from the Daytek website and the most current version of ELO-Touchsystems drivers for the touch component. The webcam is a Logitech Webcam C200 with the latest drivers from the Logitech website. The problem: If I hook any devices to the USB 2.0 sockets, it hangs the whole machine and I have to hard boot it to get it back up. If I have any devices attached to the USB 2.0 sockets when I boot up, it hangs before Windows gets to the login prompt and I have to hard boot it to recover. Workarounds found: I can plug the same devices into the on board USB 1.0 sockets and everything works fine, albeit at reduced performance. I've tried 3 different kinds of USB thumb drives, 3 different makes/models of webcams and my iPhone all with the same effect. They're recognized and don't hang the machine when I hook them to the USB 1.0 but if I hook them to the USB 2.0 ports, the machine hangs within a couple of seconds of recognizing the devices were connected. Attempted solutions: I've seen suggestions that this could be a power problem - that the PSU just doesn't have the wattage to drive these ports. While I'm doubtful this is the problem [after all the motherboard has the same standard connector regardless of the PSU wattage], I tried disabling all the on board devices that I'm not using - on board LAN, the second COM port, the AGP connector etc. through the BIOS in what I'm sure is a futile attempt to reduce the power consumption... I also modified the ACPI and power management settings. It didn't have any noticeable affect, although it didn't do any harm either. Could the wattage of the PSU really cause this problem? If it can, is there anything I need to be aware of when replacing it or do I just need to make sure it's got a higher wattage than the current one? My interpretation was that the wattage only affected the number of drives you could hook up to the power connectors, is that right? I've installed the USB card in another machine and it works without issue, so it's not a problem with the USB card itself, and Windows says the card is installed and working correctly... right up until I connect a device to it. The only thing I haven't done which I only just thought of while writing this essay is trying the USB 2.0 card in a different PCI slot, or re-ordering the wi-fi and USB cards in the slots... although I'm not sure if this will make any difference - does anyone have any experience that would suggest this might work? Other thoughts/questions: Perhaps this is an incompatibility between the USB 2.0 card and the BIOS, would re-flashing the BIOS with a newer version help? Do I need to be able to identify the manufacturer of the motherboard in order to be able to find a BIOS edition specific for this motherboard or will any version of Award BIOS function in its place? Question: Does anyone have any ideas that could help me get my USB 2.0 devices hooked up to this machine? Edit: Updated the USB 2.0 info with reference to actual card - http://www.xpcgear.com/lpnec4u.html

    Read the article

  • Best Practices - updated: which domain types should be used to run applications

    - by jsavit
    This post is one of a series of "best practices" notes for Oracle VM Server for SPARC (formerly named Logical Domains). This is an updated and enlarged version of the post on this topic originally posted October 2012. One frequent question "what type of domain should I use to run applications?" There used to be a simple answer: "run applications in guest domains in almost all cases", but now there are more things to consider. Enhancements to Oracle VM Server for SPARC and introduction of systems like the current SPARC servers including the T4 and T5 systems, the Oracle SuperCluster T5-8 and Oracle SuperCluster M6-32 provide scale and performance much higher than the original servers that ran domains. Single-CPU performance, I/O capacity, memory sizes, are much larger now, and far more demanding applications are now being hosted in logical domains. The general advice continues to be "use guest domains in almost all cases", meaning, "use virtual I/O rather than physical I/O", unless there is a specific reason to use the other domain types. The sections below will discuss the criteria for choosing between domain types. Review: division of labor and types of domain Oracle VM Server for SPARC offloads management and I/O functionality from the hypervisor to domains (also called virtual machines), providing a modern alternative to older VM architectures that use a "thick", monolithic hypervisor. This permits a simpler hypervisor design, which enhances reliability, and security. It also reduces single points of failure by assigning responsibilities to multiple system components, further improving reliability and security. Oracle VM Server for SPARC defines the following types of domain, each with their own roles: Control domain - management control point for the server, runs the logical domain daemon and constraints engine, and is used to configure domains and manage resources. The control domain is the first domain to boot on a power-up, is always an I/O domain, and is usually a service domain as well. It doesn't have to be, but there's no reason to not leverage it for virtual I/O services. There is one control domain per T-series system, and one per Physical Domain (PDom) on an M5-32 or M6-32 system. M5 and M6 systems can be physically domained, with logical domains within the physical ones. I/O domain - a domain that has been assigned physical I/O devices. The devices may be one more more PCIe root complexes (in which case the domain is also called a root complex domain). The domain has native access to all the devices on the assigned PCIe buses. The devices can be any device type supported by Solaris on the hardware platform. a SR-IOV (Single-Root I/O Virtualization) function. SR-IOV lets a physical device (also called a physical function) or PF) be subdivided into multiple virtual functions (VFs) which can be individually assigned directly to domains. SR-IOV devices currently can be Ethernet or InfiniBand devices. direct I/O ownership of one or more PCI devices residing in a PCIe bus slot. The domain has direct access to the individual devices An I/O domain has native performance and functionality for the devices it owns, unmediated by any virtualization layer. It may also have virtual devices. Service domain - a domain that provides virtual network and disk devices to guest domains. The services are defined by commands that are run in the control domain. It usually is an I/O domain as well, in order for it to have devices to virtualize and serve out. Guest domain - a domain whose devices are all virtual rather than physical: virtual network and disk devices provided by one or more service domains. In common practice, this is where applications are run. Device considerations Consider the following when choosing between virtual devices and physical devices: Virtual devices provide the best flexibility - they can be dynamically added to and removed from a running domain, and you can have a large number of them up to a per-domain device limit. Virtual devices are compatible with live migration - domains that exclusively have virtual devices can be live migrated between servers supporting domains. On the other hand: Physical devices provide the best performance - in fact, native "bare metal" performance. Virtual devices approach physical device throughput and latency, especially with virtual network devices that can now saturate 10GbE links, but physical devices are still faster. Physical I/O devices do not add load to service domains - all the I/O goes directly from the I/O domain to the device, while virtual I/O goes through service domains, which must be provided sufficient CPU and memory capacity. Physical I/O devices can be other than network and disk - we virtualize network, disk, and serial console, but physical devices can be the wide range of attachable certified devices, including things like tape and CDROM/DVD devices. In some cases the lines are now blurred: virtual devices have better performance than previously: starting with Oracle VM Server for SPARC 3.1 there is near-native virtual network performance. There is more flexibility with physical devices than before: SR-IOV devices can now be dynamically reconfigured on domains. Tradeoffs one used to have to make are now relaxed: you can often have the flexibility of virtual I/O with performance that previously required physical I/O. You can have the performance and isolation of SR-IOV with the ability to dynamically reconfigure it, just like with virtual devices. Typical deployment A service domain is generally also an I/O domain: otherwise it wouldn't have access to physical device "backends" to offer to its clients. Similarly, an I/O domain is also typically a service domain in order to leverage the available PCI buses. Control domains must be I/O domains, because they boot up first on the server and require physical I/O. It's typical for the control domain to also be a service domain too so it doesn't "waste" the I/O resources it uses. A simple configuration consists of a control domain that is also the one I/O and service domain, and some number of guest domains using virtual I/O. In production, customers typically use multiple domains with I/O and service roles to eliminate single points of failure, as described in Availability Best Practices - Avoiding Single Points of Failure . Guest domains have virtual disk and virtual devices provisioned from more than one service domain, so failure of a service domain or I/O path or device does not result in an application outage. This also permits "rolling upgrades" in which service domains are upgraded one at a time while their guests continue to operate without disruption. (It should be noted that resiliency to I/O device failures can also be provided by the single control domain, using multi-path I/O) In this type of deployment, control, I/O, and service domains are used for virtualization infrastructure, while applications run in guest domains. Changing application deployment patterns The above model has been widely and successfully used, but more configuration options are available now. Servers got bigger than the original T2000 class machines with 2 I/O buses, so there is more I/O capacity that can be used for applications. Increased server capacity made it attractive to run more vertically-scaled applications, such as databases, with higher resource requirements than the "light" applications originally seen. This made it attractive to run applications in I/O domains so they could get bare-metal native I/O performance. This is leveraged by the Oracle SuperCluster engineered systems mentioned previously. In those engineered systems, I/O domains are used for high performance applications with native I/O performance for disk and network and optimized access to the Infiniband fabric. Another technical enhancement is Single Root I/O Virtualization (SR-IOV), which make it possible to give domains direct connections and native I/O performance for selected I/O devices. Not all I/O domains own PCI complexes, and there are increasingly more I/O domains that are not service domains. They use their I/O connectivity for performance for their own applications. However, there are some limitations and considerations: at this time, a domain using physical I/O cannot be live-migrated to another server. There is also a need to plan for security and introducing unneeded dependencies: if an I/O domain is also a service domain providing virtual I/O to guests, it has the ability to affect the correct operation of its client guest domains. This is even more relevant for the control domain. where the ldm command must be protected from unauthorized (or even mistaken) use that would affect other domains. As a general rule, running applications in the service domain or the control domain should be avoided. For reference, an excellent guide to secure deployment of domains by Stefan Hinker is at Secure Deployment of Oracle VM Server for SPARC. To recap: Guest domains with virtual I/O still provide the greatest operational flexibility, including features like live migration. They should be considered the default domain type to use unless there is a specific requirement that mandates an I/O domain. I/O domains can be used for applications with the highest performance requirements. Single Root I/O Virtualization (SR-IOV) makes this more attractive by giving direct I/O access to more domains, and by permitting dynamic reconfiguration of SR-IOV devices. Today's larger systems provide multiple PCIe buses - for example, 16 buses on the T5-8 - making it possible to configure multiple I/O domains each owning their own bus. Service domains should in general not be used for applications, because compromised security in the domain, or an outage, can affect domains that depend on it. This concern can be mitigated by providing guests' their virtual I/O from more than one service domain, so interruption of service in one service domain does not cause an application outage. The control domain should in general not be used to run applications, for the same reason. Oracle SuperCluster uses the control domain for applications, but it is an exception. It's not a general purpose environment; it's an engineered system with specifically configured applications and optimization for optimal performance. These are recommended "best practices" based on conversations with a number of Oracle architects. Keep in mind that "one size does not fit all", so you should evaluate these practices in the context of your own requirements. Summary Higher capacity servers that run Oracle VM Server for SPARC are attractive for applications with the most demanding resource requirements. New deployment models permit native I/O performance for demanding applications by running them in I/O domains with direct access to their devices. This is leveraged in SPARC SuperCluster, and can be leveraged in T-series servers to provision high-performance applications running in domains. Carefully planned, this can be used to provide peak performance for critical applications. That said, the improved virtual device performance in Oracle VM Server means that the default choice should still be guest domains with virtual I/O.

    Read the article