Search Results

Search found 16978 results on 680 pages for 'event viewer'.

Page 3/680 | < Previous Page | 1 2 3 4 5 6 7 8 9 10 11 12  | Next Page >

  • Several "SideBySide" errors in the event viewer (Windows XP SP3)

    - by Wesley
    Hi all, For some reason, my netbook continuously comes up with SideBySide errors in the event viewer under Computer Management. Is there some way to get rid of these errors? My netbook occasionally BSODs and looking back into the event viewer after, at least 8 SideBySide errors were logged prior to BSOD. Please help! Thanks in advance. Netbook is a Samsung N120 with upgraded RAM to 2 GB. EDIT: So, SideBySide errors have been resolved and apparently the BSOD isn't related. But I remember specifically, that last time I had a BSOD, it was due to an "unknown hard error." What causes that?

    Read the article

  • Event Viewer shows service name as a truncated 8 character name

    - by Retrocoder
    I have written a service which logs to the Windows Event Log when it has any problems. This works fine and the service name is shown correctly in the Source column of the Event Viewer. The problem I am seeing is when my service hits some major problems like the networking layer has died etc. When this happens the event log shows errors about my service but the service name is shown as a truncated 8 character name. This name looks to be that of the executable and not the service name. Is this normal behaviour for a truncated name to be show ?

    Read the article

  • Viewing a large-resolution VNC server through a small-resolution viewer in Ubuntu

    - by Madiyaan Damha
    I have two Ubuntu computers, one with a large screen resolution (1920x1600) that is running default ubuntu vnc server. I have another computer that has a resolution of about 1200x1024 that I use to vnc into the server (I use the default ubuntu vnc viewer). Now everything works fine except there are annoying scrollbars in the viewer because the server's desktop resolution is so much higher than the viewer's. Is there a way to: 1) Scale the server's desktop down to the viewer's resolution. I know there will be a loss of image quality, but I am willing to try it out. This should be something like how windows media player or vlc scales down the window (and does some interpolation of pixels). 2) Automatically shrink the resolution of the server to the client's when I connect and scale the resolution back when I disconnect. This seems like a less attractive solution. 3) Any other solution that gurus out there use? I am sure someone has experienced this before (annoying scroll bars) so there must be a solution out there. Thanks,

    Read the article

  • slow startup of event viewer on windows 7 but fast on server 2008

    - by Tim
    Hi, Since switching to Windows 7 for my desktop I've started to get really p***ed off at the length of time it takes to start the event viewer to display the application event log (typically 20-30 secs or disk griding - presumably to load and cache all the events) I've just noticed that on server 2008 R2 it seems instantaneous. Is my experience typical? Is there any setting I can tweak to make it fast on Windows 7 as well? Tim

    Read the article

  • Oracle Solaris Cluster 4.2 Event and its SNMP Interface

    - by user12609115
    Background The cluster event SNMP interface was first introduced in Oracle Solaris Cluster 3.2 release. The details of the SNMP interface are described in the Oracle Solaris Cluster System Administration Guide and the Cluster 3.2 SNMP blog. Prior to the Oracle Solaris Cluster 4.2 release, when the event SNMP interface was enabled, it would take effect on WARNING or higher severity events. The events with WARNING or higher severity are usually for the status change of a cluster component from ONLINE to OFFLINE. The interface worked like an alert/alarm interface when some components in the cluster were out of service (changed to OFFLINE). The consumers of this interface could not get notification for all status changes and configuration changes in the cluster. Cluster Event and its SNMP Interface in Oracle Solaris Cluster 4.2 The user model of the cluster event SNMP interface is the same as what was provided in the previous releases. The cluster event SNMP interface is not enabled by default on a freshly installed cluster; you can enable it by using the cluster event SNMP administration commands on any cluster nodes. Usually, you only need to enable it on one of the cluster nodes or a subset of the cluster nodes because all cluster nodes get the same cluster events. When it is enabled, it is responsible for two basic tasks. • Logs up to 100 most recent NOTICE or higher severity events to the MIB. • Sends SNMP traps to the hosts that are configured to receive the above events. The changes in the Oracle Solaris Cluster 4.2 release are1) Introduction of the NOTICE severity for the cluster configuration and status change events.The NOTICE severity is introduced for the cluster event in the 4.2 release. It is the severity between the INFO and WARNING severity. Now all severities for the cluster events are (from low to high) • INFO (not exposed to the SNMP interface) • NOTICE (newly introduced in the 4.2 release) • WARNING • ERROR • CRITICAL • FATAL In the 4.2 release, the cluster event system is enhanced to make sure at least one event with the NOTICE or a higher severity will be generated when there is a configuration or status change from a cluster component instance. In other words, the cluster events from a cluster with the NOTICE or higher severities will cover all status and configuration changes in the cluster (include all component instances). The cluster component instance here refers to an instance of the following cluster componentsnode, quorum, resource group, resource, network interface, device group, disk, zone cluster and geo cluster heartbeat. For example, pnode1 is an instance of the cluster node component, and oracleRG is an instance of the cluster resource group. With the introduction of the NOTICE severity event, when the cluster event SNMP interface is enabled, the consumers of the SNMP interface will get notification for all status and configuration changes in the cluster. A thrid-party system management platform with the cluster SNMP interface integration can generate alarms and clear alarms programmatically, because it can get notifications for the status change from ONLINE to OFFLINE and also from OFFLINE to ONLINE. 2) Customization for the cluster event SNMP interface • The number of events logged to the MIB is 100. When the number of events stored in the MIB reaches 100 and a new qualified event arrives, the oldest event will be removed before storing the new event to the MIB (FIFO, first in, first out). The 100 is the default and minimum value for the number of events stored in the MIB. It can be changed by setting the log_number property value using the clsnmpmib command. The maximum number that can be set for the property is 500. • The cluster event SNMP interface takes effect on the NOTICE or high severity events. The NOTICE severity is also the default and lowest event severity for the SNMP interface. The SNMP interface can be configured to take effect on other higher severity events, such as WARNING or higher severity events by setting the min_severity property to the WARNING. When the min_severity property is set to the WARNING, the cluster event SNMP interface would behave the same as the previous releases (prior to the 4.2 release). Examples, • Set the number of events stored in the MIB to 200 # clsnmpmib set -p log_number=200 event • Set the interface to take effect on WARNING or higher severity events. # clsnmpmib set -p min_severity=WARNING event Administering the Cluster Event SNMP Interface Oracle Solaris Cluster provides the following three commands to administer the SNMP interface. • clsnmpmib: administer the SNMP interface, and the MIB configuration. • clsnmphost: administer hosts for the SNMP traps • clsnmpuser: administer SNMP users (specific for SNMP v3 protocol) Only clsnmpmib is changed in the 4.2 release to support the aforementioned customization of the SNMP interface. Here are some simple examples using the commands. Examples: 1. Enable the cluster event SNMP interface on the local node # clsnmpmib enable event 2. Display the status of the cluster event SNMP interface on the local node # clsnmpmib show -v 3. Configure my_host to receive the cluster event SNMP traps. # clsnmphost add my_host Cluster Event SNMP Interface uses the common agent container SNMP adaptor, which is based on the JDMK SNMP implementation as its SNMP agent infrastructure. By default, the port number for the SNMP MIB is 11161, and the port number for the SNMP traps is 11162. The port numbers can be changed by using the cacaoadm. For example, # cacaoadm list-params Print all changeable parameters. The output includes the snmp-adaptor-port and snmp-adaptor-trap-port properties. # cacaoadm set-param snmp-adaptor-port=1161 Set the SNMP MIB port number to 1161. # cacaoadm set-param snmp-adaptor-trap-port=1162 Set the SNMP trap port number to 1162. The cluster event SNMP MIB is defined in sun-cluster-event-mib.mib, which is located in the /usr/cluster/lib/mibdirectory. Its OID is 1.3.6.1.4.1.42.2.80, that can be used to walk through the MIB data. Again, for more detail information about the cluster event SNMP interface, please see the Oracle Solaris Cluster 4.2 System Administration Guide. - Leland Chen 

    Read the article

  • How to make Ultra VNC viewer faster ?

    - by karthik
    I am trying to share the screen of a system A to another system B. The normal screen sharing is good. But when i run a 3-D program in System A and try to view it from System B, i see the screen frame by frame. The response time is too slow. My Req. is to show the 3-D program to another person. How can i make VNC faster, to its best ?

    Read the article

  • HTG Explains: What The Windows Event Viewer Is and How You Can Use It

    - by Chris Hoffman
    The Windows Event Viewer shows a log of application and system messages – errors, information messages, and warnings. Scammers have used the Event Viewer to deceive people – event a properly functioning system will have error messages here. In one infamous scam, a person claiming to be from Microsoft phones someone up and instructs them to open the Event Viewer. The person is sure to see error messages here, and the scammer will ask for the person’s credit card number to fix them. As a rule of thumb, you can generally ignore all of the errors and warnings that appear in the Event Viewer – assuming your computer is working properly. HTG Explains: What The Windows Event Viewer Is and How You Can Use It HTG Explains: How Windows Uses The Task Scheduler for System Tasks HTG Explains: Why Do Hard Drives Show the Wrong Capacity in Windows?

    Read the article

  • what's the difference between Routed Events and Attached Events?

    - by vverma01
    I tried to find through various sources but still unable to understand difference between routed events and attached events in WPF. Most of the places of reference for attached event following example is used: <StackPanel Button.Click="StackPanel_Click"> <Button Content="Click Me!" Height="35" Width="150" Margin="5" /> </StackPanel> Explained as: stack panel do not contain Click event and hence Button.Click event is attached to Stack Panel. Where as msdn says: You can also name any event from any object that is accessible through the default namespace by using a typename.event partially qualified name; this syntax supports attaching handlers for routed events where the handler is intended to handle events routing from child elements, but the parent element does not also have that event in its members table. This syntax resembles an attached event syntax, but the event here is not a true attached event. Instead, you are referencing an event with a qualified name. According to MSDN information as pasted above, the above example of Buttons and StackPanel is actually a routed event example and not true attached event example. In case if above example is truly about usage of attached event (Button.Click="StackPanel_Click") then it's in contradiction to the information as provided at MSDN which says Another syntax usage that resembles typename.eventname attached event syntax but is not strictly speaking an attached event usage is when you attach handlers for routed events that are raised by child elements. You attach the handlers to a common parent, to take advantage of event routing, even though the common parent might not have the relevant routed event as a member. A similar question was raised in this Stack Overflow post, but unfortunately this question was closed before it could collect any response. Please help me to understand how attached events are different from routed events and also clarify the ambiguity as pointed above.

    Read the article

  • Log viewer server and client

    - by Scott Crooks
    I'm looking for a log viewing solution for (mostly) Linux and (preferably) Windows too. I want to be able to centralize the log information for a lot of servers so that people in the company can see what's going on for different servers. I would guess this would involve having a central server which accepts information from the various computers / virtual machines with (perhaps) a running daemon on each of the servers. Does such a software exist?

    Read the article

  • pointers to member functions in an event dispatcher

    - by derivative
    For the past few days I've been trying to come up with a robust event handling system for the game (using a component based entity system, C++, OpenGL) I've been toying with. class EventDispatcher { typedef void (*CallbackFunction)(Event* event); typedef std::unordered_map<TypeInfo, std::list<CallbackFunction>, hash_TypeInfo > TypeCallbacksMap; EventQueue* global_queue_; TypeCallbacksMap callbacks_; ... } global_queue_ is a pointer to a wrapper EventQueue of std::queue<Event*> where Event is a pure virtual class. For every type of event I want to handle, I create a new derived class of Event, e.g. SetPositionEvent. TypeInfo is a wrapper on type_info. When I initialize my data, I bind functions to events in an unordered_map using TypeInfo(typeid(Event)) as the key that corresponds to a std::list of function pointers. When an event is dispatched, I iterate over the list calling the functions on that event. Those functions then static_cast the event pointer to the actual event type, so the event dispatcher needs to know very little. The actual functions that are being bound are functions for my component managers. For instance, SetPositionEvent would be handled by void PositionManager::HandleSetPositionEvent(Event* event) { SetPositionEvent* s_p_event = static_cast<SetPositionEvent*>(event); ... } The problem I'm running into is that to store a pointer to this function, it has to be static (or so everything leads me to believe.) In a perfect world, I want to store pointers member functions of a component manager that is defined in a script or whatever. It looks like I can store the instance of the component manager as well, but the typedef for this function is no longer simple and I can't find an example of how to do it. Is there a way to store a pointer to a member function of a class (along with a class instance, or, I guess a pointer to a class instance)? Is there an easier way to address this problem?

    Read the article

  • Textbox LostFocus event fires after Command Button's OnClick event

    - by Homam
    Hi all, I have a TextBox and a ToolStripButton in a windows forms application, the TextBox implements an event handler for the LostFocus event, and the ToolStripButton implements an event handler for the Click event, but the TextBox LostFocus event fires after the ToolStripButton Click event, which event in TextBox fires before ToolStripButton click event ?

    Read the article

  • jQuery plugin for Event Driven Architecture?

    - by leeand00
    Are there any Event Driven Architecture jQuery plugins? Step 1: Subscribing The subscribers subscribe to the event handler in the middle, and pass in a callback method, as well as the name of the event they are listening for... i.e. The two green subscribers will be listening for p0 events. And the blue subscriber will be listening for p1 events. Step 2: The p0 event is fired by another component to the Event Handler A p0 event is fired to the Event Handler The event handler notifies it's subscribers of the event, calling the callback methods they specified when they subscribed in Step 1: Subscribing. Note that the blue subscriber is not notified because it was not listening for p0 events. Step 3: The p1 event is fired a component to the Event Handler The p1 event is fired by another component Just as before except that now the blue subscriber receives the event through its callback and the other two green subscribers do not receive the event. Images by leeand00, on Flickr I can't seem to find one, but my guess is that they just call it something else in Javascript/jquery Also is there a name for this pattern? Because it isn't just a basic publisher/subscriber, it has to be called something else I would think.

    Read the article

  • Report viewer in wpf and selection formula

    - by shabi
    I have a WPF application that I would like to present SQL Server Reporting Services sql 2008 reports in. I understand we have to use host widow control and then in report viewer control. I want to use remote processing mode. My code sample is : I have added namespaces: using System.Windows.Forms; using System.Windows.Forms.Integration; using Microsoft.Reporting; using Microsoft.ReportingServices; using Microsoft.Reporting.WinForms; My XAML: xmlns:wfi="clr-namespace:System.Windows.Forms.Integration;assembly=WindowsFormsIntegration" xmlns:wf="clr-namespace:System.Windows.Forms;assembly=System.Windows.Forms" xmlns:wfr="clr-namespace:Microsoft.Reporting.WinForms;assembly=Microsoft.ReportViewer.WinForms" Title="ReportHost" Height="300" Width="300"> <Grid> <wfi:WindowsFormsHost Height="100" Margin="39,27,39,0" Name="winFormsHost" VerticalAlignment="Top" > <wfr:ReportViewer x:Name="rptViewer" ProcessingMode="Remote" /> </wfi:WindowsFormsHost> </Grid> Code: rptViewer.ServerReport.ReportServerUrl = new Uri("http://mymachine-:8080/ReportServer_myreports"); rptViewer.ServerReport.ReportPath="/Reports/mytestreport.rdl"; rptViewer.ServerReport.Refresh(); My question is that how how can I set selection formula in microsoft report viewer control [like crystal report]. Or miscroft provided any this else which behave like selection formula in crystal reports. And when I run the code it show only report viewer in host window control but not the report data in window. Please some one provide me all step list, Which I have to fallow to get required result with sample code. Quick response will be appricated.

    Read the article

  • Event Viewer: atapi errors

    - by Wesley
    Specs for Samsung N120 Netbook Atom N270 @ 1.60 GHz / 160 GB IDE HDD / 2 GB PC2-5300 DDR2 RAM / Windows XP Home SP3 So I'm still getting some atapi errors in my Event Viewer. Here are two atapi errors I am getting over and over again: (1) The device, \Device\Ide\IdePort0, did not respond within the timeout period. (2) The driver detected a controller error on \Device\Ide\IdePort0. In addition, I am repeatedly getting this warning as well: (1) An error was detected on device \Device\Harddisk0\D during a paging operation. I just got this back from repair, where before, I couldn't boot at all because I was led to a black screen saying "Operating System Not Found". Still, I got it back and it can boot again, without any hard drive replacement or data loss. So, how can I get rid of these errors and warnings? What could have happened during repairs to allow my netbook to boot again? Thanks in advance.

    Read the article

  • window.event !== window.event in IE

    - by iacnats
    Code: <html> <head> <script type="text/javascript"> onload = function(){ document.getElementById('btn1').onclick = function(){ if (window === window) alert('window === window') else alert('window !== window'); if (window.event === window.event) alert('window.event === window.event') else alert('window.event !== window.event' ); } } </script> </head> <body> <button id="btn1" >click</button> </body> </html> Result: IE(i have tested IE6 - IE8) says: window === window window.event !== window.event All other browsers say: window === window window.event === window.event What's the reason for IE's response? Thanks.

    Read the article

  • Event system architecture for networking when performance is concerned

    - by Vandell
    How should I design a system for an action game (think in Golden Axe) where events can happen remotely? I'm using TCP for this because the client is in flash. There's so many options, I can make a binary protocol (I don't like this idea, I found it to be too hard to mantain) but I was also thinking that passing jsons through clients and server can be slow (Is that a exaggerated concern?). What about the internal architecture for the server? And for the client? I'm really lost, If it's a question that is too big, please indicate me some material so I can formulate a better question next time.

    Read the article

  • Crystal Reports and Report Viewer runtime question

    - by Spooky2010
    Using vs2008 c#. Howdy, Ive got an application where im trying to decide if i should use the Crystal reports or the Report viewer that comes with the visual studio install. My issue is that while it will run fine on my development machine, a lot of the machines the application will be deployed to in remote locations WONT have the runtime for either crystal reports or the report viewer installed. therefore if i build an application using either of these, and prevent user access to the reports only on the machines that do NOT have the runtimes, can the application run ok, or should i expect crazy errors on install and such Any advice appreciated.

    Read the article

  • Permissions needed to read event log messages remotely?

    - by Neolisk
    When running under a limited account, local event log messages are displaying fine, for remote computer I am getting this error: The description for Event ID ( xxxxx ) in Source ( yyyyy ) cannot be found. The local computer may not have the necessary registry information or message DLL files to display messages from a remote computer. You may be able to use the /AUXSOURCE= flag to retrieve this description; see Help and Support for details. The following information is part of the event: zzzzz. Same remote computer works fine under domain administrator. I am currently experimenting with just the Event Viewer, by using Run As. Original issue is a PowerShell script which does Get-EventLog. Are there any special permissions that need to be in place to able to read event log messages remotely? Supposedly there is a simple solution in Windows 2008 and higher, i.e. just add user to Event Log Readers group. Is there anything like that for Windows 2003?

    Read the article

  • Problem with room/screen/menu controller in python game: old rooms are not removed from memory

    - by Jordan Magnuson
    I'm literally banging my head against a wall here (as in, yes, physically, at my current location, I am damaging my cranium). Basically, I've got a Python/Pygame game with some typical game "rooms", or "screens." EG title screen, high scores screen, and the actual game room. Something bad is happening when I switch between rooms: the old room (and its various items) are not removed from memory, or from my event listener. Not only that, but every time I go back to a certain room, my number of event listeners increases, as well as the RAM being consumed! (So if I go back and forth between the title screen and the "game room", for instance, the number of event listeners and the memory usage just keep going up and up. The main issue is that all the event listeners start to add up and really drain the CPU. I'm new to Python, and don't know if I'm doing something obviously wrong here, or what. I will love you so much if you can help me with this! Below is the relevant source code. Complete source code at http://www.necessarygames.com/my_games/betraveled/betraveled_src0328.zip MAIN.PY class RoomController(object): """Controls which room is currently active (eg Title Screen)""" def __init__(self, screen, ev_manager): self.room = None self.screen = screen self.ev_manager = ev_manager self.ev_manager.register_listener(self) self.room = self.set_room(config.room) def set_room(self, room_const): #Unregister old room from ev_manager if self.room: self.room.ev_manager.unregister_listener(self.room) self.room = None #Set new room based on const if room_const == config.TITLE_SCREEN: return rooms.TitleScreen(self.screen, self.ev_manager) elif room_const == config.GAME_MODE_ROOM: return rooms.GameModeRoom(self.screen, self.ev_manager) elif room_const == config.GAME_ROOM: return rooms.GameRoom(self.screen, self.ev_manager) elif room_const == config.HIGH_SCORES_ROOM: return rooms.HighScoresRoom(self.screen, self.ev_manager) def notify(self, event): if isinstance(event, ChangeRoomRequest): if event.game_mode: config.game_mode = event.game_mode self.room = self.set_room(event.new_room) #Run game def main(): pygame.init() screen = pygame.display.set_mode(config.screen_size) ev_manager = EventManager() spinner = CPUSpinnerController(ev_manager) room_controller = RoomController(screen, ev_manager) pygame_event_controller = PyGameEventController(ev_manager) spinner.run() EVENT_MANAGER.PY class EventManager: #This object is responsible for coordinating most communication #between the Model, View, and Controller. def __init__(self): from weakref import WeakKeyDictionary self.last_listeners = {} self.listeners = WeakKeyDictionary() self.eventQueue= [] self.gui_app = None #---------------------------------------------------------------------- def register_listener(self, listener): self.listeners[listener] = 1 #---------------------------------------------------------------------- def unregister_listener(self, listener): if listener in self.listeners: del self.listeners[listener] #---------------------------------------------------------------------- def clear(self): del self.listeners[:] #---------------------------------------------------------------------- def post(self, event): # if isinstance(event, MouseButtonLeftEvent): # debug(event.name) #NOTE: copying the list like this before iterating over it, EVERY tick, is highly inefficient, #but currently has to be done because of how new listeners are added to the queue while it is running #(eg when popping cards from a deck). Should be changed. See: http://dr0id.homepage.bluewin.ch/pygame_tutorial08.html #and search for "Watch the iteration" print 'Number of listeners: ' + str(len(self.listeners)) for listener in list(self.listeners): #NOTE: If the weakref has died, it will be #automatically removed, so we don't have #to worry about it. listener.notify(event) def notify(self, event): pass #------------------------------------------------------------------------------ class PyGameEventController: """...""" def __init__(self, ev_manager): self.ev_manager = ev_manager self.ev_manager.register_listener(self) self.input_freeze = False #---------------------------------------------------------------------- def notify(self, incoming_event): if isinstance(incoming_event, UserInputFreeze): self.input_freeze = True elif isinstance(incoming_event, UserInputUnFreeze): self.input_freeze = False elif isinstance(incoming_event, TickEvent) or isinstance(incoming_event, BoardCreationTick): #Share some time with other processes, so we don't hog the cpu pygame.time.wait(5) #Handle Pygame Events for event in pygame.event.get(): #If this event manager has an associated PGU GUI app, notify it of the event if self.ev_manager.gui_app: self.ev_manager.gui_app.event(event) #Standard event handling for everything else ev = None if event.type == QUIT: ev = QuitEvent() elif event.type == pygame.MOUSEBUTTONDOWN and not self.input_freeze: if event.button == 1: #Button 1 pos = pygame.mouse.get_pos() ev = MouseButtonLeftEvent(pos) elif event.type == pygame.MOUSEBUTTONDOWN and not self.input_freeze: if event.button == 2: #Button 2 pos = pygame.mouse.get_pos() ev = MouseButtonRightEvent(pos) elif event.type == pygame.MOUSEBUTTONUP and not self.input_freeze: if event.button == 2: #Button 2 Release pos = pygame.mouse.get_pos() ev = MouseButtonRightReleaseEvent(pos) elif event.type == pygame.MOUSEMOTION: pos = pygame.mouse.get_pos() ev = MouseMoveEvent(pos) #Post event to event manager if ev: self.ev_manager.post(ev) # elif isinstance(event, BoardCreationTick): # #Share some time with other processes, so we don't hog the cpu # pygame.time.wait(5) # # #If this event manager has an associated PGU GUI app, notify it of the event # if self.ev_manager.gui_app: # self.ev_manager.gui_app.event(event) #------------------------------------------------------------------------------ class CPUSpinnerController: def __init__(self, ev_manager): self.ev_manager = ev_manager self.ev_manager.register_listener(self) self.clock = pygame.time.Clock() self.cumu_time = 0 self.keep_going = True #---------------------------------------------------------------------- def run(self): if not self.keep_going: raise Exception('dead spinner') while self.keep_going: time_passed = self.clock.tick() fps = self.clock.get_fps() self.cumu_time += time_passed self.ev_manager.post(TickEvent(time_passed, fps)) if self.cumu_time >= 1000: self.cumu_time = 0 self.ev_manager.post(SecondEvent(fps=fps)) pygame.quit() #---------------------------------------------------------------------- def notify(self, event): if isinstance(event, QuitEvent): #this will stop the while loop from running self.keep_going = False EXAMPLE CLASS USING EVENT MANAGER class Timer(object): def __init__(self, ev_manager, time_left): self.ev_manager = ev_manager self.ev_manager.register_listener(self) self.time_left = time_left self.paused = False def __repr__(self): return str(self.time_left) def pause(self): self.paused = True def unpause(self): self.paused = False def notify(self, event): #Pause Event if isinstance(event, Pause): self.pause() #Unpause Event elif isinstance(event, Unpause): self.unpause() #Second Event elif isinstance(event, SecondEvent): if not self.paused: self.time_left -= 1

    Read the article

  • How do you end up with event-sourcing if you use a xDD approach?

    - by Tomas Jansson
    When working in a TDD or BDD manner your unit tests are supposed to drive your design. But how do you end up with event-sourcing using a xDD techniques? As I see it event sourcing is something you need to adopt early on to take full advantage of it. Lets say that you start without event-sourcing and do a release. Later on when you are releasing version 2.0 you realize that it would be great to use event-sourcing, but at that point you alread have missed all the events from version 1.0 so it makes it much harder to implement. Or do you take some kind of backup of your db from before event-sourcing and use that as base line and then add event-sourcing on top of that?

    Read the article

  • XP SP2 Event log not logging events

    - by Weedfreer
    I have a problem whereby a terminal appears not to be logging events correctly and occasionally appears to have problems communicating accross the network.The terminal has previously been infected with a virus which apears to have 'played' with the default group policy in the standard user profile. Although, outwardly, the terminal appears to be working normally I still have a nagging feeling that it isn't quite back to the way it was. It was infected by a user plugging in a USB Stick while the company was using the older version of the AV software...typically a week or so before it was updated.I have configured the Event logs to Overwrite as required and to be 5056KB in Maximum size. I have also attempted:- Disabling the Event Log service & restarting Renewing the EVT files in Windows\system32\config directory Restarting the event log service and restarting Clearing the event log in the Services MMC Resetting the Filters to Default in the services MMC Using the EVENTCREATE command remotely from a CMD window on the server to force an event creation event. So far the only operation to have any sort of success is the remote computer EVENTCREATE command from a CMD window on the server. As it stands, the only other time that the computer has managed to create events is while it is being restarted.Has anyone gotany ideas on how to proceed? I'm thinking that possibly a refresh of the 'Windows\system32\config\SystemProfile' folder. I'm also thinking about running a tool such as Malwarebytes but this could be slightly controvertial as the system needs to be running on 'up-time' for as long as possible. I'm also wonderign whether anyone knows of any Windows admin tools that allow me to control the event logging options or default security options so that i could get it back to some sort of standard.What I'm trying to avoid is a complte re-imaging of the terminal. Although this is an option, I dont really want to have to take it if i dont need to.Many thanks in advance for any suggestions anyone may be able to provide.

    Read the article

  • Server 2008 email on Event variables

    - by Jeff Miles
    One of the new features of Server 2008 is the ability to attach a task to a specific event in the event logs. One of the actions available is to send an email through a SMTP server. This is working great, however it would be ideal if in the message body, the Event contents could be placed. I have tried using $eventdescription and %eventdescription%, but those are just shots in the dark. Any amount of googling produces no results. Does anyone know if this is possible? Update: Sparks' suggestion below is a step in the right direction I believe, however that method doesn't seem to work for all values. For example, I can pull the RecordID, Severity and Channel as shown, but I can't use the same method to retreive the EventID, or most importantly the description. Here's the raw XML from one event: [Event xmlns="http://schemas.microsoft.com/win/2004/08/events/event"] [System] [Provider Name="DFSR" /] [EventID Qualifiers="16384"]4412[/EventID] [Level]4[/Level] [Task]0[/Task] [Keywords]0x80000000000000[/Keywords] [TimeCreated SystemTime="2009-05-14T18:18:09.000Z" /] [EventRecordID]45692[/EventRecordID] [Channel]DFS Replication[/Channel] [Computer]servername.domain.com[/Computer] [Security /] [/System] [EventData] [Data]9046C3F4-843E-4A53-B941-4B20764072E5[/Data] [Data]D:\departments\Geomatics\Plan Quality\Data Processing\CG3533017 2009-05-13 KT FIXED[/Data] [Data]D:\departments[/Data] [Data]{26D5F604-E603-4F87-8EC3-DE9A945DA8FD}-v927199[/Data] [Data]Departments[/Data] [Data]domain.ca\files\departments[/Data] [Data]B8242CE2-F5EB-47DA-BA5B-1DD2F7EE3AB9[/Data] [Data]DFAA7A54-66CB-4C31-81A0-0F861382C32C[/Data] [Data]CG3533017 2009-05-13-{26D5F604-E603-4F87-8EC3-DE9A945DA8FD}-v927199[/Data] [/EventData] [/Event] I have tried using a ValueQuery for EventData, but it returns no data.

    Read the article

< Previous Page | 1 2 3 4 5 6 7 8 9 10 11 12  | Next Page >