  • Registering OCX on 64-bit Windows 7

    - by Jay
    I want to use MSCOMM control in my MS Excel 2010 VBA. The control shall appear in Tools-> Additional Controls dialog box in VBE of MS Excel 2010. I am trying to register MSCOMM32.OCX on my 64-bit Windows 7 machine. However, as I try to register it using regsvr32 as shown in the command window below, I am getting shown error popup. What am I missing here? Why is this component not getting registered? Or this is not the correct way to include MSCOMM control in MS Excel VBA? I have read following: Registering OCX file manually http://social.msdn.microsoft.com/Forums/en/vbgeneral/thread/1f00d6cc-00a9-4ca0-9698-535e2487af31 But to no avail.

    Read the article

  • Microsoft Access: "Can't find Language DLL msain900.dll"

    - by grammar31
    I get "Can't find Language DLL msain900.dll" in an alert box when I try to run access (both when opening an existing database and when just running it) and in any mode (regular and safe mode). Is there a way to prevent this DLL from being required? Update: I got a copy of msain900.dll from a co-worker and I put it in both System32 and in Office12; neither helped. (FYI: You can't use regsvr32 on this DLL; it's not a system file.)

    Read the article

  • Installing MFC (vs2005) application on Windows 2008 R2 64

    - by olich
    I've build an application that runs on Windows 2003, it is an old style MFC application. Today I need to install the application on a Windows 2008 R2 64 system. I have failures during installation and the application does not run. The application is build with VisualStudio2005, and uses COM objects. The MSI register the objects but it fails with the error code : HRESULT -2147010895. Any idea why the COM registration failed? I've tried to install the "Microsoft Visual C++ 2005 Redistributable Package (x86)" but it doesn't help. I've tried to register the COM objects with the regsvr32 after the installation but sadly it doesn't help. I've tries to install the application on Windows 2008 R2 32, and it works perfectly. I am quite new with 64 systems, so any help will be appreciated. tia olich

    Read the article

  • Component MSINET.OCX or one of its dependencies not correctly registered: a file is missing or invalid

    - by tintincute
    Hi can someone please help me. I'm using win7 64Bit and I'm trying to download this program "Croque-Mort" But when I do, I'm getting an error: "Component MSINET.OCX or one of its dependencies not correctly registered: a file is missing or invalid" I tried to check it by opening my cmd.exe and run as administrator and then type : regsvr32 msinet.ocx Then I got an error: "The module "MSINET.OCX" failed to load. Make sure the binary is sorted at the specified path or debug it to check for problems with the binary or depenedent .DLL files. The specified module coudl not be found" Is there a way to install this component? Would appreciate your help

    Read the article

  • Drag and drop to attachments feature only working intermittently in Outlook 2010

    - by Jared275
    I've been trying to troubleshoot a problem with my Outlook 2010 install where the ability to drag and drop an attachment into a new email will stop working from time to time. It seems to be fairly moonphase-y in that I can't seem to find a correlation in what causes it to stop working. Some searching online lead me to try running this command through the windows run dialogue: Regsvr32 ole32.dll, which apparently re-registers that particular dll as a command component in the registry. It didn't work, but I was curious as to why it was a suggested fix, and if there was something similar to try that would work, or another known solution.

    Read the article

  • Outlook 2010 on Windows 7 crashes - ieframe.dll

    - by Bryan
    Outlook 2010 is crashing rather randomly, not at any specific time like opening a preview pane or message. Event viewer gives the following Faulting application name: OUTLOOK.EXE, version: 14.0.6131.5000, time stamp: 0x509b1020 Faulting module name: ieframe.dll, version: 9.0.8112.16464, time stamp: 0x50ec98f5 Similar events have been logged only with URLMON.DLL, but with ieframe.dll more frequent. I'm looking where to start with this problem, and I'm starting with running outlook in safe mode using Outlook /safe from the start menu. Further complicating this issue are 2 programs syncing email to other calenders. Should I start with these additional programs that are syncing email as being possible culprits? Or does this have to do with Internet Explorer because of the DLL associated with these crashes? I've tried regsvr32 with both DLL's mentioned, with ieframe being unsuccessful. So my question is: what's causing Outlook to crash?

    Read the article

  • How to pull SNMP information from Windows commandline without installing software

    - by mkanet
    I would like to be able to quickly pull SNMP information via commandline such as device uptime. I noticed Net-SNMP's snmpget.exe can do this; but it looks like I need to install Net-SNMP first before I can use that executable. Isn't there any way to make this executable portable? When I simply copy it to another machine and try to execute it, it complains that netsnmp.dll is missing. If I copy that file to the same folder, it still says the file is missing. I even tried to regsvr32 that dll, but I was unsuccessful. Maybe there's a better way to get simple SNMP information from the Windows command line using royalty free/non-commercial software? Edit: It looks like I may be able to answer my own question. http://www.snmpsoft.com/freetools/snmpget.html "SNMPGet.exe"

    Read the article

  • rfid programming

    - by MaKo
    hi guys, I got a gift from a friend, 2 readers for RFID, and some cards (from a Chinese company called daily rfid), the kind of work, because it comes with some demo software written in Delphi, that reads the id of the card (myfare compatible, ISO14443A ) but the problem is that if I try to use the demo to write to them, it doesnt seem to work, it have another demo written in c#, (compiled and executable from /bin/debug, the DL600DemoCSharp.exe), the software opens, but when click on connect, I get this error Unhanded exception.. unable to load DLL 'BasicB.DLL' so I load the dll on windows/system32, but when I try regsvr32 BasicB.dll I get, error the module "BasicB.dll" was loaded but hte entry-point DllRegisterServer was not found. Make sure that "BasicB.dll" is a valid DLL or OCX file and then try again have written to the company but no response, I program in objective C, so I kind of understand c#, but how to make this cards work? - shall I continue with the delphi, and try to write to them with it - or with c# - either way I would have to write the code to read write to them,, or is there any software to work with this modules?? thanks a lot!

    Read the article

  • Need to open links in new tab in ie8 !

    - by BHOdevelopper
    I have a sidebar (right sided iframe) and when i click on a link in it, it opens a new window in IE8, (in firefox it open a new tab). What do i need to do to open links in IE8 in a new tab. I already set the Tools-Internet Options-Settings- 'Always open pop-ups in a new tab' and 'A new tab in the current window' open in new tab but still doesn't work. My links are pretty simple, what am i missing ? exemple: text. Also some site are saying to register Regsvr32 actxprxy.dll to fix this problem, still doesn't work. And i want this to work with a simple click, no 'right-click-open in new tab' option. I also hope i won't get the 'can't change how ie8 works' answer. ;)

    Read the article

  • Retrieving the COM class factory for component with CLSID {XXXX} failed due to the following error:

    - by gopal
    I developed a Windows service using C#.NET to generate PDF report. To generate PDF file I am using a third party dll. The application is running in my Windows XP platform. When I deployed the service in Windows Server 2008 64 bit version, I got this error: Retrieving the COM class factory for component with CLSID {46521B1F-0A5B-4871-A4C2-FD5C9276F4C6} failed due to the following error: 80040154. I registered the DLL using the regsvr32 command. I able to see this CLSID in the registry. But the problem persists. What could be the problem?

    Read the article

  • “Could not create the file”, “Access is denied” and “Unrecoverable build error” in building setup project in VS 2008

    - by Mister Cook
    When building a setup project I get a message: Error with setup build: Error 27 Could not create the file 'C:\Users\MyName\AppData\Local\Temp\VSI1E1A.tmp' 'Access is denied.' I have tried the following (from http://support.microsoft.com/kb/329214/EN-US) regsvr32 "C:\Program Files (x86)\Common Files\Microsoft Shared\MSI Tools\mergemod.dll" The DLL registers but this does not fix my problem. Also, I tried a Clean build, deleting the temp folder, ran VS2008 as administratror, restart my PC but it occurs every time. I have no anti-virus software running and running on Windows 7 64-bit. This operation worked fine until recently. I have read many other users see this but found no solution. The only half solution I found was to edit setup properties and switch to Package files as Loose uncompressed files. This works but is not ideal as I need a full installer.

    Read the article

  • Add button to Internet Explorer toolbar during run time

    - by karikari
    I am currently create a simple additional button to my Internet Explorer 7, toolbar. The button works. I am using Visual C++. But now, I would like to create a to create a button during my Internet Explorer is running. Means, on certain condition, my program (a dll registered with regsvr32) will add a button to the toolbar. and after certain condition, the button also can be disappeared. How can I achieve this?

    Read the article

  • COM on Windows7 and Visual Studio

    - by vikasde
    I registered a COM dll (under administrator) using regsvr32, which I want to use in Visual Studio 2008 (under administrator) for my project in Windows 7. Now, when I try to use the interfaces and classes from the COM, then I can't see any of the methods. When I use the object browser to view the COM classes, then I can see that they are all empty. However when I use the same COM on windows XP using VS2008, then all methods are suddenly available. Does anybody know why this is happening and how to get this working under Windows 7?

    Read the article

  • Can I use manifests to specify an optional dependency on a COM server?

    - by sharptooth
    I'd like to use manifests to specify a dependency on a COM server (reg-free COM). The consumer application will mostly work fine without the COM server - only something like 1,7% of its functionality uses the COM server. So with plain old regsvr32 it would start and work fine until the user would do something that would trigger CoCreateInstance() call and at that point the consumer would get an error message. Now I've played with manifests for a while and it looks like the consumer wouldn't even start unless the COM server assembly it depends on is present in the file system. That's no good. Is there a way to use reg-free COM with manifests and make the dependency optional - so that the consumer program starts and works fine until CoCreateInstance() is actually called?

    Read the article

  • Can't register 32bit dll under 64bit windows

    - by Wodzu
    Hi guys. I try to create a COM object from my JS script like this: function main() { var MyApplication = new ActiveXObject("Base.Application"); } main(); I am getting error: "Automation server can't create object". This error occurs on Windows 2003 64 bit. The dll is 32 bit and it works fine on 32 bit systems. I've tried both versions of Regsvr32.exe on the 64 bit system and both versions told me that dll registered succesfully. Unfortunatelly the error message does not tell me why it can not create object. The reason is unknown, it might be that it can't create object because it is still not registered or it might be something totally different... I've also add full permisions to this dll. I don't know what else I can do, do you have any ideas?

    Read the article

  • Install MatroskaProp on Windows 7 x64

    - by Neophytos
    To see more information in Windows Explorer property pages and menus about Matroska Video (.mkv) files, similar to what one can see when selecting native Windows media (.avi, .asf, .wmv or even just plain old mpg) files, Matroska links (from http://www.matroska.org/downloads/windows.html) to a download of the MatroskaProp shell extension (http://www.jory.info/serendipity/archives/14-MatroskaProp-2.8-Released.html). It used to work for me under Windows XP 32-bit. Now I have Windows 7 x64, and downloaded, installed and ran it. Configuration and settings page is fine. But it does not seem to actually register any shell extension. Nothing is added to Explorer windows, menus or property pages when selecting .mkv or .mks files). I tried calling the register hook manually using regsvr32.dll, that again invoked the configuration window and let me set all options, and when confirming even said the registration succeeded, but seems to have had no effect. In the registry I cannot find any traces of the shell extension being installed. Can this extension be made to work under Windows 7 or x64 systems? Are there known problems with installing this or other old shell extensions on x64, or on Windows 7?

    Read the article

  • Making the iPhone work with stripped down Windows XP

    - by Gabriel
    Hi, this is my first time posting here and I have a really specific question. I have an ASUS eee 901 running Windows XP Home. I had everything working well, but then I decided to improve performance by moving Windows to the smaller but faster internal SSD. I used Nlite to strip down Windows, following the instructions here: http://wiki.eeeuser.com/howto:nlitexp I now have a very lightweight installation of XP home with SP3 and all the current updates. Almost everything is working really well. I have installed iTunes and I CAN sync with no problems. However, each time I plug in my iPhone 3GS (latest firmware), Windows tries and fails to install drivers. The Found New Hardware Wizard launches, but nothing I do will make it complete successfully, with the result that the iphone does not show up in Windows as removable storage, or as a camera. When I launch the Camera and Scanner Wizard, it shows only my webcam, not the iphone. I have verified that I have the following files in place: Windows\System32\ptpusb.dll (regsvr32 successful) Windows\System32\ptpusd.dll (entry point not found, can not be registered) Windows\System32\usbaaplrc.dll (entry point not found, can not be registered) Windows\System32\drivers\usbaapl.sys Windows\System32\drivers\usbscan.sys Windows\System32\drivers\usbstor.sys Does anyone know if some other file is required or if there's some other element preventing this from working? Edit (From posted answer) I did select Cameras & Camcorders, and my webcam is working fine for video & still capture.

    Read the article

  • Windows Update Agent Update Failed

    - by Adrian Godong
    I'm trying to install the latest version of Windows Update Agent, v7.2.6001.788, and the installation failed with error code of 0x800b0100. Running Windows Server 2008 SP1. The relevant WindowsUpdate.log section: 2009-08-03 16:17:49:334 3544 d28 Misc =========== Logging initialized (build: 7.2.6001.788, tz: +0100) =========== 2009-08-03 16:17:49:334 3544 d28 Misc = Process: d:\fcc0f96e893296900e6501a601\wusetup.exe 2009-08-03 16:17:49:332 3544 d28 Setup Windows Update Client standalone setup : resource dll path is d:\fcc0f96e893296900e6501a601\en\wusetup.exe.mui 2009-08-03 16:17:49:335 3544 d28 Setup Evaluating CBS package "d:\fcc0f96e893296900e6501a601\WUClient-SelfUpdate-Core-TopLevel.cab" 2009-08-03 16:17:49:556 3544 d28 Setup Package will be installed 2009-08-03 16:17:49:556 3544 d28 Setup Evaluating CBS package "d:\fcc0f96e893296900e6501a601\WUClient-SelfUpdate-ActiveX.cab" 2009-08-03 16:17:49:580 3544 d28 Setup Package will be installed 2009-08-03 16:17:49:580 3544 d28 Setup Evaluating CBS package "d:\fcc0f96e893296900e6501a601\WUClient-SelfUpdate-Aux-TopLevel.cab" 2009-08-03 16:17:49:665 3544 d28 Setup Package will be installed 2009-08-03 16:17:49:709 3544 d28 Setup Windows Update Client standalone setup : eula file path is d:\fcc0f96e893296900e6501a601\en\eula.rtf 2009-08-03 16:17:52:337 3544 de0 Misc WARNING: LoadLibrary failed for srclient.dll with hr:8007007E 2009-08-03 16:17:52:338 3544 de0 Setup Installing CBS package "d:\fcc0f96e893296900e6501a601\WUClient-SelfUpdate-Core-TopLevel.cab" 2009-08-03 16:17:53:895 3544 de0 Setup WARNING: CBS operation failed, error = 0x800B0100 2009-08-03 16:17:53:898 3544 de0 Setup WARNING: Install of setup package "d:\fcc0f96e893296900e6501a601\WUClient-SelfUpdate-Core-TopLevel.cab" failed, error = 0x800B0100 2009-08-03 16:18:04:976 3544 d28 Setup wusetup has finished. Exit code is 0. Reboot is NOT needed I think something went wrong twhen loading the srclient.dll. Things that I have done and still no fix: msiexec /unregister and msiexec /register regsvr32 wuapi.dll Run CheckSUR tool and restart

    Read the article

  • Unregistering COM dll with a C# Setup Project

    - by lb
    Hi All. I've been stuck on this one for a while. I'll try explain in the simplest terms and at the best of my knowledge. I will honour any help. I've got a C# project which uses a VB6 compiled ActiveX DLL that I'm constantly updating. I compile the setup project, send it to the client and they run the setup. When building the updated setup project, I would increase the 'Version' of the setup project so it wouldn't bother with 'Another version is already installed'. What started happening after a few updates I began to notice the DLL would not be updated to the new version in the installer. The client computer had the original DLL both installed and registered. First symptom: method not found exceptions from the client C# code. This is not a shared DLL and only this application needs it. I've noticed that when uninstalling the application (through the usual procedure) the DLL is also not removed from the application folder although I would set this file's property 'Permanent' to false. The registration entries in the registry are mantained also. I do update in VS6.0 the version of the DLL (usually increase the build number) before building it. Then in VS2008, I remove it from the References, and add it again from the 'Browse tab', without re-registering it on my dev machine and adding it from the COM tab. I've thought of these options. Custom step in Setup project to regsvr32.exe /u 'hardcoded path of my dll' at uninstall (ugly) Somehow find out how the 'Isolate' property can work for me without registering Find out how to execute setup project 'Conditions' that would actually check the version of the library and to update the file accordingly at every install) Any help would be incredibly welcome.

    Read the article

  • Can I use manifests to consume a COM server without specifying its version?

    - by sharptooth
    Two of our programs use the same COM server (also made by us) with the same class ids. Each program when installing copies the COM server files into its folder and regsvr32s the COM server. The problem is how to install the COM server so that the user can install either one or both of our programs into different folders in any order and likely of different versions. Clearly it's impossible without changing the class ids and that's lots of hassle with configurations. Ideally we would like to use manifests for that and go without regsvr32. The problem is every time I read about reg-free COM (for example, here) there's the version attribute in the assemblyIdentity. The version number should change every nightly build and I totally don't like the idea of (automatically) adjusting it. I understand why specifying dependency on a specific version is good, but it's completely useless in our scenarion. Is there a way to write manifests for both the COM server and the consumer so that they don't specify versions and just work with whatever version of the file happens to be in the folder? Also is there a way to restrict the search to the same folder as the consumer?

    Read the article

  • IE8 Refuses to run Javascript from Local Hard Drive

    - by Josh Stodola
    I have a problem that just started at work recently and the network manager is certain he did not change anything with the group policy. Anyways, here is a detailed description of the problem. My machine is Windows XP SP3, and I use IE8 to browse. We have McAffee anti-virus software that I am unable to configure. I use the following file to test... <!DOCTYPE html> <html> <head> <title>Javascript Test</title> </head> <body> <script type="text/javascript"> document.write("<h1>PASS</h1>"); </script> <noscript> <h1>FAIL</h1> </noscript> </body> </html> When I open this file from the C: drive, it fails every time. If I execute it anywhere else (local/remote web server or on a mapped network drive), it works just fine. When I am simply browsing the Internet, Javascript on web sites works just fine. It is only failing on files running from my C: drive. Additionally, I have had a couple other programmers in the department try this file on their C: drive, and it works fine for them. So I don't believe it is a group policy thing. I need to fix this because I do extensive testing from my C: drive, and I am accustomed to doing so. I don't want to get into the habit of moving files to a different drive just to test. Things I have tried: Enabled "Allow Active Content to Run Files on My Computer" in Options | Advanced | Security Enabled "Allow Active Scripting" in Options | Security | Custom Level Verified that "Script" was not checked as disabled in Developer Toolbar Added localhost to Trusted Sites in Options Disabled McAffee completely (momentarily, with help from network admin) Used an older DOCTYPE in my test HTML page Re-installed IE8 completely Ran regsvr32 on the JScript.dll Slammed keyboard I am sure that there is a setting somewhere that will fix this problem, possibly in the registry. I would not be surprised if it was related to the developer toolbar. At this point I do not know where else to look. Can anyone help me resolve this problem? EDIT: Regardless of the bounty, this issue is still ongoing.

    Read the article

  • WiX Action Sequence

    - by Damian Vogel
    I was looking for list of actions and their sequence when running a WiX setup. Somehow the official website doesn't seem to provide any information. The basic problem is that I want to schedule my custom actions correctly. Typically I need to register a DLL with regsvr32.exe, and this can only be done once the files are copied to the harddrive. However the custom action <Custom Action="RegisterShellExt" After="InstallFiles"> failed with the error message "file not found". What I've done then is analizing the log of my MSI with WiX Edit, and I've found that the Action InstallFiles exists more than once. And effectively the files are written only the second time it appears. So I changed my custom action to the following : <Custom Action="RegisterShellExt" Before="InstallFinalize"> Here is the sequence I've extracted from the logs of my MSI: Action start 15:16:49: INSTALL. Action start 15:16:49: PrepareDlg. Action start 15:16:49: AppSearch. Action start 15:16:49: LaunchConditions. Action start 15:16:49: ValidateProductID. Action start 15:16:49: DIRCA_NEWRETARGETABLEPROPERTY1.5D429292039C46FCA3253E37B4DA262A. Action start 15:16:50: CostInitialize. Action start 15:16:50: FileCost. Action start 15:16:50: CostFinalize. Action start 15:16:50: WelcomeDlg. Action 15:16:51: LicenseAgreementDlg. Dialog created Action 15:16:53: CustomizeDlg. Dialog created Action 15:16:55: VerifyReadyDlg. Dialog created Action start 15:16:56: ProgressDlg. Action start 15:16:56: ExecuteAction. Action start 15:16:58: INSTALL. Action start 15:16:58: AppSearch. Action start 15:16:58: LaunchConditions. Action start 15:16:58: ValidateProductID. Action start 15:16:58: CostInitialize. Action start 15:16:59: FileCost. Action start 15:16:59: CostFinalize. Action start 15:16:59: InstallValidate. Action start 15:17:00: InstallInitialize. Action start 15:17:08: ProcessComponents. Action 15:17:09: GenerateScript. Generating script operations for action: Action ended 15:17:09: ProcessComponents. Return value 1. Action start 15:17:09: UnpublishFeatures. Action start 15:17:09: RemoveShortcuts. Action start 15:17:09: RemoveFiles. Action start 15:17:09: InstallFiles. Action start 15:17:10: CreateShortcuts. Action start 15:17:10: RegisterUser. Action start 15:17:10: RegisterProduct. Action start 15:17:10: PublishFeatures. Action start 15:17:10: PublishProduct. Action start 15:17:10: ConfigureInstaller. Action start 15:17:10: InstallFinalize. Action 15:17:10: ProcessComponents. Updating component registration Action 15:17:12: InstallFiles. Copying new files Action 15:17:21: CreateShortcuts. Creating shortcuts Action 15:17:21: RegisterProduct. Registering product Action 15:17:23: ConfigureInstaller. [[note: CustomAction]] Action 15:17:22: PublishFeatures. Publishing Product Features Begin CustomAction 'ConfigureInstaller' Action 15:17:28: RollbackCleanup. Removing backup files Action ended 15:17:28: InstallFinalize. Return value 1. Action start 15:17:28: RegisterShellExt. [[note: CustomAction]] Action ended 15:17:33: INSTALL. Return value 1. Action start 15:17:35: ExitDialog. Does anyone know an official listing?

    Read the article

  • An easy way to create Side by Side registrationless COM Manifests with Visual Studio

    - by Rick Strahl
    Here's something I didn't find out until today: You can use Visual Studio to easily create registrationless COM manifest files for you with just a couple of small steps. Registrationless COM lets you use COM component without them being registered in the registry. This means it's possible to deploy COM components along with another application using plain xcopy semantics. To be sure it's rarely quite that easy - you need to watch out for dependencies - but if you know you have COM components that are light weight and have no or known dependencies it's easy to get everything into a single folder and off you go. Registrationless COM works via manifest files which carry the same name as the executable plus a .manifest extension (ie. yourapp.exe.manifest) I'm going to use a Visual FoxPro COM object as an example and create a simple Windows Forms app that calls the component - without that component being registered. Let's take a walk down memory lane… Create a COM Component I start by creating a FoxPro COM component because that's what I know and am working with here in my legacy environment. You can use VB classic or C++ ATL object if that's more to your liking. Here's a real simple Fox one: DEFINE CLASS SimpleServer as Session OLEPUBLIC FUNCTION HelloWorld(lcName) RETURN "Hello " + lcName ENDDEFINE Compile it into a DLL COM component with: BUILD MTDLL simpleserver FROM simpleserver RECOMPILE And to make sure it works test it quickly from Visual FoxPro: server = CREATEOBJECT("simpleServer.simpleserver") MESSAGEBOX( server.HelloWorld("Rick") ) Using Visual Studio to create a Manifest File for a COM Component Next open Visual Studio and create a new executable project - a Console App or WinForms or WPF application will all do. Go to the References Node Select Add Reference Use the Browse tab and find your compiled DLL to import  Next you'll see your assembly in the project. Right click on the reference and select Properties Click on the Isolated DropDown and select True Compile and that's all there's to it. Visual Studio will create a App.exe.manifest file right alongside your application's EXE. The manifest file created looks like this: xml version="1.0" encoding="utf-8"? assembly xsi:schemaLocation="urn:schemas-microsoft-com:asm.v1 assembly.adaptive.xsd" manifestVersion="1.0" xmlns:asmv1="urn:schemas-microsoft-com:asm.v1" xmlns:asmv2="urn:schemas-microsoft-com:asm.v2" xmlns:asmv3="urn:schemas-microsoft-com:asm.v3" xmlns:dsig="http://www.w3.org/2000/09/xmldsig#" xmlns:co.v1="urn:schemas-microsoft-com:clickonce.v1" xmlns:co.v2="urn:schemas-microsoft-com:clickonce.v2" xmlns="urn:schemas-microsoft-com:asm.v1" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" assemblyIdentity name="App.exe" version="1.0.0.0" processorArchitecture="x86" type="win32" / file name="simpleserver.DLL" asmv2:size="27293" hash xmlns="urn:schemas-microsoft-com:asm.v2" dsig:Transforms dsig:Transform Algorithm="urn:schemas-microsoft-com:HashTransforms.Identity" / dsig:Transforms dsig:DigestMethod Algorithm="http://www.w3.org/2000/09/xmldsig#sha1" / dsig:DigestValuepuq+ua20bbidGOWhPOxfquztBCU=dsig:DigestValue hash typelib tlbid="{f10346e2-c9d9-47f7-81d1-74059cc15c3c}" version="1.0" helpdir="" resourceid="0" flags="HASDISKIMAGE" / comClass clsid="{af2c2811-0657-4264-a1f5-06d033a969ff}" threadingModel="Apartment" tlbid="{f10346e2-c9d9-47f7-81d1-74059cc15c3c}" progid="simpleserver.SimpleServer" description="simpleserver.SimpleServer" / file assembly Now let's finish our super complex console app to test with: using System; using System.Collections.Generic; using System.Text; namespace ConsoleApplication1 {     class Program     {         static voidMain(string[] args)         { Type type = Type.GetTypeFromProgID("simpleserver.simpleserver",true); dynamic server = Activator.CreateInstance(type); Console.WriteLine(server.HelloWorld("rick")); Console.ReadLine(); } } } Now run the Console Application… As expected that should work. And why not? The COM component is still registered, right? :-) Nothing tricky about that. Let's unregister the COM component and then re-run and see what happens. Go to the Command Prompt Change to the folder where the DLL is installed Unregister with: RegSvr32 -u simpleserver.dll      To be sure that the COM component no longer works, check it out with the same test you used earlier (ie. o = CREATEOBJECT("SimpleServer.SimpleServer") in your development environment or VBScript etc.). Make sure you run the EXE and you don't re-compile the application or else Visual Studio will complain that it can't find the COM component in the registry while compiling. In fact now that we have our .manifest file you can remove the COM object from the project. When you run run the EXE from Windows Explorer or a command prompt to avoid the recompile. Watch out for embedded Manifest Files Now recompile your .NET project and run it… and it will most likely fail! The problem is that .NET applications by default embeds a manifest file into the compiled EXE application which results in the externally created manifest file being completely ignored. Only one manifest can be applied at a time and the compiled manifest takes precedency. Uh, thanks Visual Studio - not very helpful… Note that if you use another development tool like Visual FoxPro to create your EXE this won't be an issue as long as the tool doesn't automatically add a manifest file. Creating a Visual FoxPro EXE for example will work immediately with the generated manifest file as is. If you are using .NET and Visual Studio you have a couple of options of getting around this: Remove the embedded manifest file Copy the contents of the generated manifest file into a project manifest file and compile that in To remove an embedded manifest in a Visual Studio project: Open the Project Properties (Alt-Enter on project node) Go down to Resources | Manifest and select | Create Application without a Manifest   You can now add use the external manifest file and it will actually be respected when the app runs. The other option is to let Visual Studio create the manifest file on disk and then explicitly add the manifest file into the project. Notice on the dialog above I did this for app.exe.manifest and the manifest actually shows up in the list. If I select this file it will be compiled into the EXE and be used in lieu of any external files and that works as well. Remove the simpleserver.dll reference so you can compile your code and run the application. Now it should work without COM registration of the component. Personally I prefer external manifests because they can be modified after the fact - compiled manifests are evil in my mind because they are immutable - once they are there they can't be overriden or changed. So I prefer an external manifest. However, if you are absolutely sure nothing needs to change and you don't want anybody messing with your manifest, you can also embed it. The option to either is there. Watch for Manifest Caching While working trying to get this to work I ran into some problems at first. Specifically when it wasn't working at first (due to the embedded schema) I played with various different manifest layouts in different files etc.. There are a number of different ways to actually represent manifest files including offloading to separate folder (more on that later). A few times I made deliberate errors in the schema file and I found that regardless of what I did once the app failed or worked no amount of changing of the manifest file would make it behave differently. It appears that Windows is caching the manifest data for a given EXE or DLL. It takes a restart or a recompile of either the EXE or the DLL to clear the caching. Recompile your servers in order to see manifest changes unless there's an outright failure of an invalid manifest file. If the app starts the manifest is being read and caches immediately. This can be very confusing especially if you don't know that it's happening. I found myself always recompiling the exe after each run and before making any changes to the manifest file. Don't forget about Runtimes of COM Objects In the example I used above I used a Visual FoxPro COM component. Visual FoxPro is a runtime based environment so if I'm going to distribute an application that uses a FoxPro COM object the runtimes need to be distributed as well. The same is true of classic Visual Basic applications. Assuming that you don't know whether the runtimes are installed on the target machines make sure to install all the additional files in the EXE's directory alongside the COM DLL. In the case of Visual FoxPro the target folder should contain: The EXE  App.exe The Manifest file (unless it's compiled in) App.exe.manifest The COM object DLL (simpleserver.dll) Visual FoxPro Runtimes: VFP9t.dll (or VFP9r.dll for non-multithreaded dlls), vfp9rENU.dll, msvcr71.dll All these files should be in the same folder. Debugging Manifest load Errors If you for some reason get your manifest loading wrong there are a couple of useful tools available - SxSTrace and SxSParse. These two tools can be a huge help in debugging manifest loading errors. Put the following into a batch file (SxS_Trace.bat for example): sxstrace Trace -logfile:sxs.bin sxstrace Parse -logfile:sxs.bin -outfile:sxs.txt Then start the batch file before running your EXE. Make sure there's no caching happening as described in the previous section. For example, if I go into the manifest file and explicitly break the CLSID and/or ProgID I get a detailed report on where the EXE is looking for the manifest and what it's reading. Eventually the trace gives me an error like this: INFO: Parsing Manifest File C:\wwapps\Conf\SideBySide\Code\app.EXE.     INFO: Manifest Definition Identity is App.exe,processorArchitecture="x86",type="win32",version="1.0.0.0".     ERROR: Line 13: The value {AAaf2c2811-0657-4264-a1f5-06d033a969ff} of attribute clsid in element comClass is invalid. ERROR: Activation Context generation failed. End Activation Context Generation. pinpointing nicely where the error lies. Pay special attention to the various attributes - they have to match exactly in the different sections of the manifest file(s). Multiple COM Objects The manifest file that Visual Studio creates is actually quite more complex than is required for basic registrationless COM object invokation. The manifest file can be simplified a lot actually by stripping off various namespaces and removing the type library references altogether. Here's an example of a simplified manifest file that actually includes references to 2 COM servers: xml version="1.0" encoding="utf-8"? assembly xmlns="urn:schemas-microsoft-com:asm.v1" manifestVersion="1.0" assemblyIdentity name="App.exe" version="1.0.0.0" processorArchitecture="x86" type="win32" / file name="simpleserver.DLL" comClass clsid="{af2c2811-0657-4264-a1f5-06d033a969ff}" threadingModel="Apartment" progid="simpleserver.SimpleServer" description="simpleserver.SimpleServer" / file file name = "sidebysidedeploy.dll" comClass clsid="{EF82B819-7963-4C36-9443-3978CD94F57C}" progid="sidebysidedeploy.SidebysidedeployServer" description="SidebySideDeploy Server" threadingModel="apartment" / file assembly Simple enough right? Routing to separate Manifest Files and Folders In the examples above all files ended up in the application's root folder - all the DLLs, support files and runtimes. Sometimes that's not so desirable and you can actually create separate manifest files. The easiest way to do this is to create a manifest file that 'routes' to another manifest file in a separate folder. Basically you create a new 'assembly identity' via a named id. You can then create a folder and another manifest with the id plus .manifest that points at the actual file. In this example I create: App.exe.manifest A folder called App.deploy A manifest file in App.deploy All DLLs and runtimes in App.deploy Let's start with that master manifest file. This file only holds a reference to another manifest file: App.exe.manifest xml version="1.0" encoding="UTF-8" standalone="yes"? assembly xmlns="urn:schemas-microsoft-com:asm.v1" manifestVersion="1.0" assemblyIdentity name="App.exe" version="1.0.0.0" processorArchitecture="x86" type="win32" / dependency dependentAssembly assemblyIdentity name="App.deploy" version="1.0.0.0" type="win32" / dependentAssembly dependency assembly   Note this file only contains a dependency to App.deploy which is another manifest id. I can then create App.deploy.manifest in the current folder or in an App.deploy folder. In this case I'll create App.deploy and in it copy the DLLs and support runtimes. I then create App.deploy.manifest. App.deploy.manifest xml version="1.0" encoding="UTF-8" standalone="yes"? assembly xmlns="urn:schemas-microsoft-com:asm.v1" manifestVersion="1.0" assemblyIdentity name="App.deploy" type="win32" version="1.0.0.0" / file name="simpleserver.DLL" comClass clsid="{af2c2811-0657-4264-a1f5-06d033a969ff}" threadingModel="Apartment" progid="simpleserver.SimpleServer" description="simpleserver.SimpleServer" / file file name="sidebysidedeploy.dll" comClass clsid="{EF82B819-7963-4C36-9443-3978CD94F57C}" threadingModel="Apartment" progid="sidebysidedeploy.SidebysidedeployServer" description="SidebySideDeploy Server" / file assembly   In this manifest file I then host my COM DLLs and any support runtimes. This is quite useful if you have lots of DLLs you are referencing or if you need to have separate configuration and application files that are associated with the COM object. This way the operation of your main application and the COM objects it interacts with is somewhat separated. You can see the two folders here:   Routing Manifests to different Folders In theory registrationless COM should be pretty easy in painless - you've seen the configuration manifest files and it certainly doesn't look very complicated, right? But the devil's in the details. The ActivationContext API (SxS - side by side activation) is very intolerant of small errors in the XML or formatting of the keys, so be really careful when setting up components, especially if you are manually editing these files. If you do run into trouble SxsTrace/SxsParse are a huge help to track down the problems. And remember that if you do have problems that you'll need to recompile your EXEs or DLLs for the SxS APIs to refresh themselves properly. All of this gets even more fun if you want to do registrationless COM inside of IIS :-) But I'll leave that for another blog post…© Rick Strahl, West Wind Technologies, 2005-2011Posted in COM  .NET  FoxPro   Tweet (function() { var po = document.createElement('script'); po.type = 'text/javascript'; po.async = true; po.src = 'https://apis.google.com/js/plusone.js'; var s = document.getElementsByTagName('script')[0]; s.parentNode.insertBefore(po, s); })();

    Read the article

< Previous Page | 1 2 3