  • Windows XP corrupts registry every several hours

    - by Ilya Kazakevich
    There is a Dell XPS 400 with Windows Media Center installer. It is installed on RAID (Intel Matrix Storage) which is built-in chipset south bridge. Raid has two 150 Gb WDC drivers connected as mirror. All drivers and updates are installed( sp3 and so on). A week ago PC changed its video mode to 256 colors (like VESA mode) and after several moments I got BSOD: c000021a: 0xc0000005 Doctor watson did not create dump although it is installed as default debugger. After reboot it said that config file is missing or corrupted. So, I boot to recovery console and found that registry file (config) is so small. I've replaced it with one from recovery point and windows booted sucessfully. But after about 3 hrs -- it has crashed again in the same wat! I look in event viewer: is said that Explorer.exe failed to open \global??\DLIAFS. I look in winobj, and found that it is a device. I made "deny from everyone" for this device ACL, and after several hours my windows crashed. I restored registry, boot again and there was no error about DLIAFS. I did full chkdsk and it did not found anything bad. But I found event about error paging to \Harddrive1\D. I do not have pagefile there, but I thought I should check my disk again. Unfortunatelly I cannt use smart tools for RAID, but I downloaded latest software from Intel (it can do the same things like RAID bios can but from windows). It verified my disks, found some errors, fix them, than I rebooted. And it crashed again. I am lost. What (except kernel debugging) could be done here? Thanks

    Read the article

  • Windows XP corrupts registry every several hours

    - by Ilya Kazakevich
    There is a Dell XPS 400 with Windows Media Center installer. It is installed on RAID (Intel Matrix Storage) which is built-in chipset south bridge. Raid has two 150 Gb WDC drivers connected as mirror. All drivers and updates are installed( sp3 and so on). A week ago PC changed its video mode to 256 colors (like VESA mode) and after several moments I got BSOD: c000021a: 0xc0000005 Doctor watson did not create dump although it is installed as default debugger. After reboot it said that config file is missing or corrupted. So, I boot to recovery console and found that registry file (config) is so small. I've replaced it with one from recovery point and windows booted sucessfully. But after about 3 hrs -- it has crashed again in the same wat! I look in event viewer: is said that Explorer.exe failed to open \global??\DLIAFS. I look in winobj, and found that it is a device. I made "deny from everyone" for this device ACL, and after several hours my windows crashed. I restored registry, boot again and there was no error about DLIAFS. I did full chkdsk and it did not found anything bad. But I found event about error paging to \Harddrive1\D. I do not have pagefile there, but I thought I should check my disk again. Unfortunatelly I cannt use smart tools for RAID, but I downloaded latest software from Intel (it can do the same things like RAID bios can but from windows). It verified my disks, found some errors, fix them, than I rebooted. And it crashed again. I am lost. What (except kernel debugging) could be done here? Thanks

    Read the article

  • My Computer hangs for a few minutes just after startup, and then is fine.

    - by EvilChookie
    So I just built myself a reasonably beefy computer, and I installed Windows 7 on it. However, I start the machine up each morning and within a few minutes, the computer will semi hang. That is the mouse is responsive, and most of the time I can open task manager, or a new tab in Chrome. Occasionally windows will be labelled as 'Not responding'. Then, the machine will get over it's problem, and will be nice and quick until I turn it off. Here's my specs: CPU: AMD Phenom-II X4 955 Black (Quad Core, 3.2ghz) RAM: 4GB of DDR3 1300 MOBO: ASUS M4A785T-M (Latest BIOS) HARD DRIVES: 2x1TB Western Digital Caviar Blacks in RAID-0. OS: Windows 7 Ultimate x64. GPU: ASUS GT240 1GB. I believe this issue relates to the RAID array, as I didn't have the lockup problem before I created the array. I purchased a second drive and reformatted after creating a RAID array, since the single drive was a little on the pokey side (compared to the rest of the computer). What I have tried: Updated Raid Drivers Malware checks Windows Updates Unecessary Services CPU and Disk activity appears to be low (via Resource Monitor) No strange errors in the error log. Any thoughts?

    Read the article

  • Windows 8 x64 with VMWare Workstation or inside ESXi

    - by Dommer
    I need to run several virtual machines on a core i7-920 box with 12GB or RAM and a 256GB SSD to host the VMs. It also has a Highpoint RocketRaid 2720SGL RAID controller with a 12TB RAID 5 array. I want one of my VMs to run Windows 8 x64, to have access to the RAID array as a native disk (not as networked drives and it needs to run at full speed) and to be able to send files quickly across the network. Initially I thought I'd try to do this using ESXi 5, but I have been unable to find any working RAID drivers for the RR2720SGL and it is not on the HCL for ESXi 5. In light of this, I have installed Windows 8 x64 on the hardware and am thinking of installing VMWare Workstation and running my VMs inside there. I guess my questions are these: How does VMWare Workstation 9 perform compared to ESXi 5? In the real world I mean? Presumably installing Win 8 as the host OS will give me way better performance for that Win 8 machine than Win 8 running under ESXi? I should stick with Windows 8 x64 as the host OS, right? If I install a domain controller VM inside my Win 8 box and join the Win 8 machine to that domain, am I insane (I would guess the Win 8 machine wouldn't see the domain controller until it finished starting everything up, but I don't think that matters)?! is it feasible to give metrics like this and if so, what is the likely value of x? 25%? 50%? 75%? Win 8 under ESXi runs x% as fast as Win 8 installed bare metal.

    Read the article

  • FreeNas on Dell Powervault 745N: 2TB Limit?

    - by willoller
    I want to purchase 2 x 2TB drives, and install FreeNas on my Dell Powervault 745N. People on the internets seem to be having trouble with the MD3000 firmware, and I want to make sure I can solve any issues before buying the drives. Before I invest, I have 3 questions : Is there a partition size limit determined by the RAID controller? That is, could I have a striped 4TB partition? The spec sheets make me wonder if the RAID controller needs all 4 drives in order to work. Is there any reason this will have to run in RAID5? If I buy 4 matching drives, would the controller support a RAID6 configuration? I'm basically new to all this RAID stuff - sorry for any noob questions.

    Read the article

  • Is There Anyway to Undo a Quick Initialize from a Perc6/i VD?

    - by Carlo71
    I stupidly fast initialized an existing Raid 5 Array Virtual disk with 10 Virtual Machines after creating a new Raid 5 Array. The VDs switched order on the list of the Perc Controller. My server is a PowerEdge R710 with a Perc 6/i Raid controller running ESXi 5.1. The Bios of the R710 and the Perc 6/i controller are both running the latest firmware. I tried the steps on this article: http://www.caseyfulton.com/dell-perc-6i-fast-initialize-how-to-restore/. However the BartPE just freezes on the Windows XP slapsh page. Does anybody know a full proof method? I have backups of the VMs, however I would like to avoid restoring all of them due to time constraint.

    Read the article

  • RAID1 rebuild fails due to disk errors

    - by overlord_tm
    Quick info: Dell R410 with 2x500GB drives in RAID1 on H700 Adapter Recently one of drives in RAID1 array on server failed, lets call it Drive 0. RAID controller marked it as fault and put it offline. I replaced faulty disk with new one (same series and manufacturer, just bigger) and configured new disk as hot spare. Rebuild from Drive1 started immediately and after 1.5 hour I got message that Drive 1 failed. Server was unresponsive (kernel panic) and required reboot. Given that half hour before this error rebuild was at about 40%, I estimated that new drive is not in sync yet and tried to reboot just with Drive 1. RAID controller complained a bit about missing RAID arrays, but it found foreign RAID array on Drive 1 and I imported it. Server booted and it runs (from degraded RAID). Here is SMART data for disks. Drive 0 (the one that failed first) ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 1 Raw_Read_Error_Rate POSR-K 200 200 051 - 1 3 Spin_Up_Time POS--K 142 142 021 - 3866 4 Start_Stop_Count -O--CK 100 100 000 - 12 5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0 7 Seek_Error_Rate -OSR-K 200 200 000 - 0 9 Power_On_Hours -O--CK 086 086 000 - 10432 10 Spin_Retry_Count -O--CK 100 253 000 - 0 11 Calibration_Retry_Count -O--CK 100 253 000 - 0 12 Power_Cycle_Count -O--CK 100 100 000 - 11 192 Power-Off_Retract_Count -O--CK 200 200 000 - 10 193 Load_Cycle_Count -O--CK 200 200 000 - 1 194 Temperature_Celsius -O---K 112 106 000 - 31 196 Reallocated_Event_Count -O--CK 200 200 000 - 0 197 Current_Pending_Sector -O--CK 200 200 000 - 0 198 Offline_Uncorrectable ----CK 200 200 000 - 0 199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0 200 Multi_Zone_Error_Rate ---R-- 200 198 000 - 3 And Drive 1 (the drive which was reported healthy from controller until rebuild was attempted) ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 1 Raw_Read_Error_Rate POSR-K 200 200 051 - 35 3 Spin_Up_Time POS--K 143 143 021 - 3841 4 Start_Stop_Count -O--CK 100 100 000 - 12 5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0 7 Seek_Error_Rate -OSR-K 200 200 000 - 0 9 Power_On_Hours -O--CK 086 086 000 - 10455 10 Spin_Retry_Count -O--CK 100 253 000 - 0 11 Calibration_Retry_Count -O--CK 100 253 000 - 0 12 Power_Cycle_Count -O--CK 100 100 000 - 11 192 Power-Off_Retract_Count -O--CK 200 200 000 - 10 193 Load_Cycle_Count -O--CK 200 200 000 - 1 194 Temperature_Celsius -O---K 114 105 000 - 29 196 Reallocated_Event_Count -O--CK 200 200 000 - 0 197 Current_Pending_Sector -O--CK 200 200 000 - 3 198 Offline_Uncorrectable ----CK 100 253 000 - 0 199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0 200 Multi_Zone_Error_Rate ---R-- 100 253 000 - 0 In extended error logs from SMART I found: Drive 0 has only one error Error 1 [0] occurred at disk power-on lifetime: 10282 hours (428 days + 10 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 10 -- 51 00 18 00 00 00 6a 24 20 40 00 Error: IDNF at LBA = 0x006a2420 = 6956064 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- 61 00 60 00 f8 00 00 00 6a 24 20 40 00 17d+20:25:18.105 WRITE FPDMA QUEUED 61 00 18 00 60 00 00 00 6a 24 00 40 00 17d+20:25:18.105 WRITE FPDMA QUEUED 61 00 80 00 58 00 00 00 6a 23 80 40 00 17d+20:25:18.105 WRITE FPDMA QUEUED 61 00 68 00 50 00 00 00 6a 23 18 40 00 17d+20:25:18.105 WRITE FPDMA QUEUED 61 00 10 00 10 00 00 00 6a 23 00 40 00 17d+20:25:18.104 WRITE FPDMA QUEUED But Drive 1 has 883 errors. I see only few last ones and all errors I can see look like this: Error 883 [18] occurred at disk power-on lifetime: 10454 hours (435 days + 14 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 01 -- 51 00 80 00 00 39 97 19 c2 40 00 Error: AMNF at LBA = 0x399719c2 = 966203842 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- 60 00 80 00 00 00 00 39 97 19 80 40 00 1d+00:25:57.802 READ FPDMA QUEUED 2f 00 00 00 01 00 00 00 00 00 10 40 00 1d+00:25:57.779 READ LOG EXT 60 00 80 00 00 00 00 39 97 19 80 40 00 1d+00:25:55.704 READ FPDMA QUEUED 2f 00 00 00 01 00 00 00 00 00 10 40 00 1d+00:25:55.681 READ LOG EXT 60 00 80 00 00 00 00 39 97 19 80 40 00 1d+00:25:53.606 READ FPDMA QUEUED Given those errors, is there any way I can rebuild RAID back, or should I make backup, shutdown server, replace disks with new ones and restore it? What about if I dd faulty disk to new one from linux running on USB/CD? Also, if anyone have more experiences, what could be causes for those errors? Crappy controller or disks? Disks are about 1 year old, but it is pretty unbelievable to me that both would die within so short timespan.

    Read the article

  • HP DL180 G6 P410 8x SATA 1TB, what is the optimal configuration?

    - by Oneiroi
    I have a HP DL180 G6 with a P410 raid controller. Presently this runs using 4x 1TB Samsung Spinpoint SATA drives, in a RAID10 configuration using default settings. I am about to add a backplane to increase the drive capacity from 4 to 12 drives, and I plan to install 4 more 1TB SATA Drives. The drives are matched and have close serial numbers (They arrived together in the Manufacturers pallet). Model HD103UJ 1000GB/7200rpm/32M Rated for 3GB/s I will also be installing RHEL 6.1 x86_64. My question is what would be the optimal RAID settings (stripe etc.) for this configuration? To recap: 8x Model HD103UJ 1000GB/7200rpm/32M Rated for 3GB/s RAID 10 configuration. Thanks in advance. Update for role: Server is to become an iscsi target for an internal openstack deployment currently underway. (Glance) Will also provide virtualisation through KVM

    Read the article

  • RAID across SAS controller ports

    - by BlueGene
    Hi, I'm managing a HP DL360 G5 machine. It has a SAS controller with two ports. Port 1 is attached to 4 drive bays and Port 2 has 2 bays. The machine currently has 3 drives connected to Port 1 with RAID 5 configuration. I'm trying to max out the bays by adding 1 disk in port 1 and 2 in port 2. Can I group those three disks(1 disk-port, 2 disks-port 2) in a RAID 5 configuration?

    Read the article

  • How to re-do the hard disks in a WD Word Book Edition II ?

    - by jfmessier
    I recently purchased a WD World Book II, a 2 TB one. I call it the "White Box". It has those 2 1TB drives, and they were in this RAID 1 config, only giving me about 1 TB. I could not delete the raid array, and I took the drives in a Linux box. But I also deleted the entire partitions of the disks, and I cannot even et the existing RAID array on this WD White Box. The drives are fine, but I cannot get them to work on the WD White Box. My goal was to get back to a real 2 TB storage space. If I cannot get those drives back in the White Box, I can re-use them elsewhere, but this would mean a waste of the firmware and network connection. After the fact, I read that, anyway, the network performance is rather poor. Thanks :-)

    Read the article

  • Clonezilla is not able to clone a RAID 1 disk

    - by Adrian
    I have a HP Server DL320 G5. There are two SATA hard disks configured as RAID 1 through HP embedded RAID controller. Server OS is running GNU/Linux (Fedora) Server booted up with clonezilla live CD. The image will be stored on a NAS connected through NFS. Clonezilla could mount the NFS share and could see the two hard disks /dev/sda and /dev/sdb. I selected /dev/sda for disk cloning. However I could not see the cloning progress and got straight into a prompt for reboot, poweroff, command line I tried to select /dev/sdb but the same issue.

    Read the article

  • Strange performance from RAID5 using WD RE4 disks

    - by Howard
    I've noticed a bit of a performance issue with some WD RE4 drives I'm using under AMD's hardware RAID solution. First a bit of background: Environment: Windows 7 home premium x64 HDD's: 3x 1TB WD Raid Edition 4 in a RAID 5 setup with 128 kbyte stripe (2TB usable space) Testing Tool: HD Tune, process set to "High Priority" Processor: AMD Phenom II x6 1100T Ram: 16GB DDR3/1600mhz Motherboard: MSI 970A-G45 The image below pretty much depicts the issue I'm having. Every test has the same thing, a period of similar length where the performance drops to a few megabytes a second. This can't be a TLER issue as the purpose of RE4's is to work around that. Any help would be greatly appreciated.

    Read the article

  • Server 2008 R2 - Boot disk RAID 1 - migrate to larger disk

    - by William Hooper
    My group inherited several 2008 R2 servers with single 70GB RAID 1 boot/system disks. No other disks in the servers. We need larger boot / system disk. Plan is : to replace one disk with new 500 GB drive wait for resync replace other smaller disk with 2nd 500 GB drive wait for resysnc Now I should have 500 GB RAID 1 with original 70 GB partition Then I would like to extend the 70 GB partition to 200 GB and add D: drive partition with remaining 300 GB Can the above be done using Windows Disk Management and / or Windows DiskPart ?

    Read the article

  • SATA drive not recognized when installing RHEL 5.1 on PowerEdge R410

    - by Rachel
    Here's my setup: Dell R410 with Perc S100 (software) raid controller on an Intel ICH10R chipset The first problem is that the Perc S100 is only supported on windows. I'm trying to install RHEL 5.1. It boots from the cdrom, but later the installer can't see the cdrom or hard drive. Both are connected to the on-board sata controller. The only options in the R410 bios for SATA are ATA or RAID. I don't need raid, I just want a single drive setup.

    Read the article

  • File corruption when copying different file on raid 1

    - by Stephan
    I have a RAID 1 configuration of 2 1TB drives on a Fedora 12 box. Most of what is stored there are video files that are numerical labeled. The problem I'm having is that I had one of the video files get corrupted. I copied a replacement from a backup and replaced the bad file and now it works fine. However, after doing this the next numbered file goes from 350MB to 200KB and all but about .5 second of video disappears. If I then replace that file it happens to the next one down the line. Ex: Replace corrupt file 1.avi and file 2.avi shrinks to 200KB. Replace now corrupted 2.avi and it works but 3.avi gets screwed up. I have run SMART tests on the drives and they report fine. Does anyone have any tests I can run to try to figure out what is going on? EDIT: It is a two disk software RAID 1 with an ext4 filesystem

    Read the article

  • LVM mirroring VS RAID1

    - by syrenity
    Hi. Having learned a bit about LVM mirroring, I thought about replacing the current RAID-1 scheme I'm using to gain some flexibility. Problem is that according to what I found on the Internet, LVM is: 1) Slower then RAID-1, at least in reading (as only single volume being used for reading). 2) Non-reliable on power interrupts, and requires disk cache disabling for prevention of data loss. http://www.joshbryan.com/blog/2008/01/02/lvm2-mirrors-vs-md-raid-1/ Also it seems, at least to several setup guides I read (http://www.tcpdump.com/kb/os/linux/lvm-mirroring/intro.html), that one actually requires a 3rd disk for storing the LVM log. This makes the setup completely unusable on 2 disks installations, and lowers the amount of used mirror disks on higher amount of disks. Can anyone comment the above facts, and let me know his experience of using LVM mirroring? Thanks.

    Read the article

  • Terrible Performance with SATA Drives on Dell PowerEdge, steps to troubleshoot?

    - by Tom
    I had asked this question earlier and the question went missing so here it is again. Bought a DELL Poweredge 2950 to use as in-house QA Server. Disk performance is beyond terrible, 1000-4000 ms response time on the drive with our SQL Server database .mdf. Sql Server disk queue upwards of 300 at times. I'm a software guy, can anyone help me with steps to determine the issue? I don't know what RAID controller it has, how can I determine that? I'm speculating it could be BIOS issue. Perhaps the server used to have another kind of drive in it and when I added SATA the ??? buffer size is wrong??? Perhaps I chose wrong options (chose defaults) when setting up the RAID 1 arrays? I thought RAID 1 was a performance array?

    Read the article

  • Dell PowerEdge 6850 Degraded HDD

    - by Matt
    Good Morning, We have a dell power edge 6850 with a degraded drive in the RAID array. I have never had to recover such an issue, so any help or advice would be welcome. Basically it hasn't affected the server at an operating system level, but has slowed down performance, I have a replacement drive in hand but as this is our main database server I want to proceed with extreme caution. My options as I see them are - Can I just hot swap the degraded drive with the new one and the data will automatically re-sync and we are all back to normal presumably this is dependant on the current raid configuration? reading various comments on-line I may need to re-configure the RAID array and re-build the broken drive? This screams disaster to me with the main worry being that I wipe any other data. Option 1 would of course make my day. Thanks in advance

    Read the article

  • Clone a Red Hat RAID as part of a disaster recovery plan

    - by Campo
    I am looking for recommendations to clone a Red Hat mirrored raid to a single hard drive located in the same machine. The idea is if the servers hardware ever has an issue we have a similar hardware machine ready to go. All we would have to do is pop in the cloned drive. If the servers RAID ever failed we could just switch to the single drive to maintain uptime and restore the original configuration on the spare server with a backup. This is a restaurant and they are open 7 days a week. We do have time from 12:am to 9:00am to perform the necessary steps for a clone and we talking about under 10 Gigs of information. There is a database on the server. I have looked into Rsync and Clonezilla. But I am just not confident either is capable of completing the task I want. Looking for some suggestions and possibly a step by step if you could be so kind.

    Read the article

  • X58 RAID 10 - Am I forced to use Sata2?

    - by Avi
    I'm building a new dev computer. It will be running a few VMWare Worksation virtual machines. I was advised on Serverfault to use Raid10 for performance. Raid 10 uses 4 disks. I contacted my supplier who suggested a gigabyte X58A motherboard and 4 Western Digital Caviar black 6Gb/s disks. I have checked the spec for the X58A board, however, and it says: SATA 3Gb/s: RAID 0, RAID 1, RAID 5, and RAID 10 SATA 6Gb/s: RAID 0, and RAID 1. I'm losing half the bandwidth because I'm forced to use SATA2! What should I do?

    Read the article

  • Lustre - is this bad form?

    - by ethrbunny
    Im going to be consolidating several 'server rooms' into a single installation soon. Part of this effort will be finding a home for 5Tb (and growing) of files / logs. To this end Im looking at Lustre and appreciating its ability to scale. The big vendors want to sell me a $20K SAN to manage this but Im wondering about buying several iSCSI units (like this http://www.asacomputers.com/3U-iSCSI-Solution.html) and using VMs for the OSS machines. This would let me fail-over to cover problems and not require a dedicated system for each OSS. Given articles like this (http://h30565.www3.hp.com/t5/Feature-Articles/RAID-Is-Dead-Long-Live-RAID/ba-p/1422) that talk about how RAID is not keeping up with drive density Im leaning towards more disks with lower capacity each. Again - some akin to the iSCSI array above. Tell me why this is a terrible idea. Do I really need to invest in a PE710 for each OSS/OST?

    Read the article

  • What does the the reconstruction process of mdadm do exactly on raid10

    - by Azrael
    I've got a system with 4 disks set up as raid10. All disks are usable, and mdadm all states them with UUUU. Due to a recent system crash, the raid is currently reconstruction the raid as it was marked as "not clean," and a reconstruction process was started. On a closer look smartctl shows problems on one disk: sd 0:0:0:0: [sda] Unhandled sense code sd 0:0:0:0: [sda] Result: hostbyte=DID_OK driverbyte=DRIVER_SENSE sd 0:0:0:0: [sda] Sense Key : Medium Error [current] [descriptor] Descriptor sense data with sense descriptors (in hex): 72 03 11 04 00 00 00 0c 00 0a 80 00 00 00 00 00 24 cd 78 d4 sd 0:0:0:0: [sda] Add. Sense: Unrecovered read error - auto reallocate failed sd 0:0:0:0: [sda] CDB: Read(10): 28 00 24 cd 75 1e 00 04 00 00 With a research about the reconstruction process, I only found information concerning raid5 but nothing for raid10. Can I replace this problematic disk during the reconstruction process, or will I kill the raid with this?

    Read the article

  • Raid 5 scsi fault

    - by HaLaBi
    I have no much knowledge about servers and I was looking all day around the internet about finding a solution to my raid 5 problem. All of a sudden two disks failed. The server won't boot (HP Proliant, windows 2003 R2, very old maybe 10 years old). I know that if one disk is faulty then I can add a new disk and rebuild it and things will be fine, the problem is two went faulty :( is this normal? two at the same time? is there any other thing I can do and I am not aware of? other than taking them out and reinserting them back? Windows won't boot. The Array menu shows that disks 0 and 4 are "Missing". Any other tricks or things to do? It is important because for some unknown reason the back up job did not work for a month and I just found out, so I need to make these raid 5 back online again.

    Read the article

  • Restoring raid 5 array after bios flash

    - by cogergo
    I have just flashed my BIOS and now my machine does not detect my raid5 array! It has three 2TB drives in it so that is a LOT of data that will be lost! I have NOT deleted the array and it does not offer me to reboot I'm using Nvidia MediaShield! and Windows 7. Any ideas guys? Thanks! Update: here is the GUI raid configuration. As you see it shows one disk in the array but for some reason not the other two! Click for image of raid configuration error

    Read the article

  • Server refuses to boot when Raid5 disk is disconnected - /root/ missing

    - by Ronni
    I recently set up a NAS server running a Debian OS (6.0.4) It contains 4 disks, 3 of them are in a Raid5 array, while the last one is used for the OS. To simulate a disk-failure I unplugged one of the raid disks, which resulted in the OS being unable to boot. It started the boot, recognized that md0 (the raid array) was running on 2/3 disks, and then threw a few errors. It was unable to find the following directories: /dev/root on /root, /dev on /root/dev, /sys on /root/sys, /proc on /root/proc It appears this happens regardless of which raid disk is removed. These directories are supposed to be on /dev/sdd my system disk. Output from fstab and blkid : http://dl.dropbox.com/u/6017799/NASOutput.txt If you need additional info, please let me know.