  • DB DOC Enhancements for Oracle SQL Developer v4

    - by thatjeffsmith
    One of our more popular features is ‘DB Doc.’ It’s like JAVADOC for the database. Pick a connection, right-click, and go. It will generate an HTML documentation set for that schema. For version 4, we’ve introduced a few enhancements based on user requests. That’s right, you asked, and we listened. Added support for Package Bodies Added parallelization option for larger doc sets Enhanced the HTML formatting a bit Select Your Object Types and Generation Options We’ve changed the default selection of object types to be included and added support for package bodies There’s also an option to auto-open the documentation set after it’s been generated. And the HTML As Requested

    Read the article

  • Organizing Connections with Folders in Oracle SQL Developer

    - by thatjeffsmith
    How many Oracle databases do you work with on a regular basis? I’m guessing the answer for most of you lies between 1 and 500. This post is really geared for those of you who deal with more than just a handful (5) of database connections. Filters are nice when you need to work with a subset of table data, or even a list of tables. So why wouldn’t they be just as useful for organizing your connections? Here’s my complete list of databases: The folders aren’t there by default, you add them as you need them. Now this isn’t an overly large connection list. But when I need to fire up an impromptu demo for a customer, it’s very nice to be able to drill down into JUST those ‘safe’ environments. This actually saves me a few seconds every time I need to connect to one of my databases. So while it’s a very simple feature, it’s one of those things that I recommend EVERYONE take advantage of as it will save them hours of time over the long haul. Easier to find means I get to work a few seconds faster. This also helps me from making mistakes in ‘production’ environments! How to Add a Connection Folder Select a connection you want to organize. Mouse-right-click, and choose ‘Add to folder.’ You can throw it into a new container or an existing one. Lather, rinse, and repeat as necessary. The only trick is remembering to right-click! Special thanks to @dresendi for today’s topic! He asked how to do this and I realized I hadn’t blogged the topic yet

    Read the article

  • How can I parse/ transform text log data before it gets captured in SCOM 2007 R2?

    - by Abs
    I'm pretty much a noob with System Center Operations Manager 2007, and I'm probably missing something pretty basic, but I'm stumped anyway. We're setting up monitoring on some of our servers, and we'd like to capture data from some plain text log files (e.g. DNS debug logs, DHCP logs). It looks to me like I can set up a generic text file monitoring rule and get events captured into the main Ops Manager database, but my understanding is that the whole line of text from the plain text log gets captured as one field. In an ideal world, we'd be able to parse or transform that log file data to make it easier to query later. Is this possible? Is it easy? Do I have to buy expensive 3rd-party software to do it? One more thing: it would be even better if there was a way to stuff this data into the Audit Collection Services (ACS) database instead of the main one, but I'll take what I can get. Any help would be greatly appreciated.

    Read the article

  • File downloaded from IIS6/Win2003 server to a Mac (and not PCs) is incredibly slow

    - by Simon Swords
    We have a test zip file on our customers server that we host for him that when downloading to a Mac is incredibly slow. On a Mac - trying the download via Safari 5.0.3 and Chrome 8.0.552.231 results in a quick burst of normal download speed then plummets to almost no speed at all after 1 or 2 meg (between 1 and 5 Kb/s - yes, KiloBITS per second! According to the network monitor). Downloading via Windows was fine and speedy. Tested via; IE7 7.0.5730.13 and Chrome Portable 8.0.552.224 On Windows XP Pro, and; IE8 8.0.7600.16385 in a Windows 7 virtual machine running via VirtualBox 4.0.0 r69151 on the same Mac mention above Google hasn't helped us out on this occasion, possibly because the search terms I'm having to use are quite generic. Has anybody ever experienced this and if so how do we fix it? Thanks in advance

    Read the article

  • Current wisdom on SQL Server and Hyperthreading?

    - by BradC
    Lots of articles out there (see Slava Oks's original SQL 2000 article and Kevin Kline's SQL 2005 update) recommend disabling hyperthreading on SQL servers, or at least testing your specific workload before enabling it on your servers. This issue is gradually becoming less relevant as true multi-core processors replace hyperthreaded ones, but what's the current wisdom on this issue? Does this advice change any with SQL 2005 64-bit, or SQL 2008, or Windows Server 2008? Ideally, this should be tested in advance in a staging environment, but what about for servers that have already made it into production with HT enabled? How can I tell if performance issues we're experiencing might be related to HT? Is there some specific combination of perfmon counters that might point me in that direction, as opposed to all the other things I normally pursue when working on improving SQL performance? Edit: This is especially attractive because of the potential for an across the board improvement for some of my high-cpu servers, but the client is going to want to see something concrete that helps me identify which servers really could benefit from disabling hyperthreading. Of course, conventional performance troubleshooting is ongoing, but sometimes any little bit helps.

    Read the article

  • VS2008 VB project - Changing application type automatically adds references

    - by Stijn
    Visual Basic Create a new project with the Empty Project template (Visual Basic - Windows) Go to the project properties, and change the Application type by choosing something else or reselecting Windows Forms Application. When reselecting, Visual Studio will automatically add references to System.Deployment, System.Drawing and System.Windows.Forms C# Create a new project with the Empty Project template (Visual C# - Windows) Go to the project properties, and change the Application type to any of the choices. Visual studio will not add references. Question Is there a way to change this behaviour for Visual Basic?

    Read the article

  • How to Shrink large Hyper-V VM

    - by autrevo
    Using Disk2VHD utility I converted my bare-metal OS into Hyper-V VHD - http://technet.microsoft.com/en-us/sysinternals/ee656415.aspx And I could obtain a huge 190GB VHD file. Apart from performance issues, this VHD worked fine as guest when hosted on Windows Server 200 R2, Hyper-V. Having realized need to keeping only system files and application installations on VHD. I have deleted most of the junk data from this VHD and now it contains only 20-25 GB. But I am not able to shrink the VHD VM. Having done some research, I came to know, this as a limitation of .VHD files. Subsequently I followed these two step using Edit Virtual Hard Wizard on Windows 2012 Box. Convert from VHD to VHDX (took close to 3 hrs.) Compact (Another 4 hrs.) This did not ever shrink the VHDX either. Does Hyper-V does not provide proper support to handle large VHDs or VHDXs whose size are the range of 200GB.

    Read the article

  • How to add IP range to a server?

    - by Efe Cakinberk
    Hello, First of all I must say that I'm ver inexperienced server and network user. But I rented a unmanaged dedicated server. Well I didn't know what unmanaged really means, then I learned it when I needed support. Well I must do everything by myself. I have a problem. I had already 4 IPs on my server when I rented it. But then I needed more Ips and my server assigned me 32 Ips in which I can only use 27 of them. 85.25.230.0 - 85.25.230.31 this is my Ip range and they say the following Ips must not be configured on the server: 85.25.230.0 - network address 85.25.230.1 - gateway address 85.25.230.2 - router redundancy 85.25.230.3 - router redundancy 85.25.230.31 - broadcast address But the problem is ok Ips are assigned to me but they are not setup on my server. How will I setup Ips to work on my server? I did this after my reseach on google: I used this command on command prompt: route add 85.25.230.0 mask 255.255.255.224 85.25.230.1 metric 1 if then it said OK!. and I thought they should be working. (btw, mask is given to me by my ISP and I don't know metric 1 and if means I just saw it on the net and write it here) I setup my domains via using Plesk Kontrol Panel. So i added one domain and setup one of my new Ips 85.25.230.5 to it. But no it is not working. When I visit the domain via browser, there is a Plesk page comes and says this domain is not configured on the server. Then I changed the domains Ip to one of my old Ips which are given to me with the server and which I have been using for my other domains for a long time. Ok in a second, domain started working. I set it back to my new Ip and domain did not work. As I said, I'm not an expert and do not now the logic. But I'm eager to learn. Can you tell me what might couse the problem and did I do wrong while setting up IP RANGE to my server, if so how can I set them up? Thank you, Efe

    Read the article

  • Windows XP SP3 client printer error over AD

    - by Alex
    I have Windows Server 2008r2 and a Windows XP SP3 client machine in Active Directory. My problem is that I've installed the printer on the windows server and shared it, the permissions are right, but when i try to connect to that printer from the windows xp client, it throws the following errer: "You do not have sufficient access to your computer to connect to the selected printer". Again, the permissions are right. I think I'm missing something that I couldn't find on the web. :( please help!

    Read the article

  • Why does a group policy not applied to the domain administrator account?

    - by Saariko
    I have a working policy on my entire domain. I just found out, when logging with the domain administrator, that this policy is not applied (EDIT: Running : gpresult shows that the GPO's are applied - but, this GPO is for Drive Mappings, and the actual drive mappings are NOT shown) The administrator account - does not have any login script on his profile tab. My GPO's are mainly small/atomic settings: single GPO to handle each settings: UAC, Firewall, printers. GPO status for the object is enabled That's an overview of the Drive Maps: Reading on MS support site, I checked the delegation tab, and it is marked as applied to domain and enterprise admins. Every user gets these policies correctly. The OU that is set is the root of the domain. (for testing purpose - I did that to eliminate hierarchy issues - did not help) Block Inheritance is disabled. (never used it anyway) GPO link GPO Security Filterings

    Read the article

  • How much memory will a Windows file-server be able to use effectively.

    - by Zoredache
    In the near future we will be moving our fileserver to a newer box that will be running Windows 2008R2. I want to know how much memory Windows will be able to use for a system that is just a file-server. In searching around I found an old document for Windows 2000 that mentions the maximum size of the file-system cache is 960MB. I suspect this limit no longer applies, but is there a new limit? The file server will be just a standard Windows fileserver. It will have 1TB of attached storage. The large majority of the of the files accessed during the day are just typical Office documents. There are 80-100 people usually using the fileserver during a typical day. This system will only be used as a file server, it doesn't have any other roles. In Windows 2008r2 is there any hard limits for the filesystem cache? What are they? The server we will be re-using for this purpose currently has 4GB of memory, but it can be maxed out at 16GB. Is there any value in doing this for a Windows file-server? Are there any performance counters can I look at on the existing 2003 fileserver that will tell me if adding more memory will be worthwhile.

    Read the article

  • Dell External SAS 5/E HBA and Hyper-V

    - by JohnyD
    I have a Dell R710 running Win2008 R2 + Hyper-V with dual SAS 5/E HBA's. I'm building a Linux VM to install Bacula on and I need to connect it to my Dell PowerVault 124T via the SAS HBA. I've been doing some looking online and I have yet to find a straightforward answer on how to connect a SAS HBA to a VM, let alone a Linux VM. The flavor is Ubuntu 32-bit.

    Read the article

  • SQL Server Agent refuses to start

    - by Geo Ego
    I'm having a problem with SQL Server 2005 where the SQL Server Agent suddenly refuses to start. If I attempt to start it through Services, I get the error "SQL Server Agent (MSSQLSERVER) service on Local Computer started and then stopped." In the Application log, I have the following entry: Event Type: Error Event Source: SQLSERVERAGENT Event Category: Service Control Event ID: 103 Date: 5/20/2010 Time: 11:07:07 AM User: N/A Computer: SHAREPOINT Description: SQLServerAgent could not be started (reason: Unable to connect to server 'SHAREPOINT'; SQLServerAgent cannot start). This database has been running fine for four months. It contains a SharePoint configuration database, which two days ago stopped working, throwing me a message that the configuration database cannot be reached. It was then that I realized the SQL Server Agent was not running, and I have been unable to restart it. I have tried running it with both the local system account and the network service account, with the same results. So far, I have tried: Granting the administrators group, network service, and SharePoint SQL Server Agent account public and sysadmin roles on the database. Granting the administrators group, network service, and SharePoint SQL Server Agent account full permissions to the entire MSSQL directory and all files within. I still have no joy.

    Read the article

  • Exchange 2007 Standard Edition

    - by Phrontiste
    We Have : Exchange 2007 Standard Edition IBM System X3650 2 x Intel Xeon 5430 2.66 GHz Version 8.1 Build 240.6 Mailbox, Hub Transport, Client Access Role Installed on One Box Total Number of Mailboxes : 110 - 130 6 Physical Disks Disk 0,1 (68 GB) = Raid-1, OS Partition ( C: Partition) Disk 2,3 (279GB) = Raid-1, Exchange Database (First and Second Storage Groups) ( D: Partition ) Disk 4,5 (68 GB) = Raid-1, Exchange Transaction Logs ( E: Partition ) Setup: Storage Groups : D:\First Storage group\Mailbox database.edb Storage Groups : D:\Second Storage Group\Public Folder Database.edb Transaction Logs : E Partition Problem 1: On our D Partition (Mailbox Database Partition), total size is 279 GB, free space remaining is 64.7 GB, when I select the first storage group and second storage group folders and right click properties they report a size of 165 GB. Mailbox database reports a size of 157GB when right clicked Properties. where as the size displayed in the folder is 164,893,456 KB So, we are missing around 50-54 GB, there is nothing else on these drives, no page file, nothing at all. The partition housing the Transaction logs is reporting the sizes accurately. Any suggestions / fixes on the above ? Problem 2: As you may have already read in Problem 1, the size of the mailbox database is 157GB or 164GB reported; which is not recommended, a) What would you suggest we should do to divide mailboxes in storage groups on this same server ? b) How would we move mailboxes into different storage groups ? c) This is the information store size ? (Am I right in thinking that this is not recommended) d) Having multiple storage groups with one Mailbox DB in each, would that reduce the size of the Information Store? e) Any suggestions / how-to reduce the size of information store ? We didn't install this, we have inherited this - what other recommendations you can make in order to keep ourselves better prepared for any server disaster? We are backing up with Yosemite Backup on RD1000 (320GB) at the moment, which is backing up successfully, flushing the logs daily. We haven't done a test restore YET. I have tried to provide as much info as possible, please let me know if you need further info. Also, we haven't yet faced any problems in mailflow, access speeds, everything is working fine, we have two to five people accessing OWA or Outlook via vpn only. Thanks for your time to read the above - will look forward to your expert suggestions.

    Read the article

  • Hyper-V Machine drifts time all over, even with NTP

    - by MichaelGG
    Resolved The problem was Hyper-V on that machine. I removed Hyper-V, installed VMware Server, ran the same VM. Time sync issues went away (< 100ms difference after a day). My setup is like this: HYV1 - HyperV machine (non domain) - sync irrelevant AD1 - VM AD server on HYV1, sync'd to time.nist.gov. HyperV time sync off. S1 - Physical machine, sync'd to domain. S2 - Physical machine running HyperV, sync'd to domain. V1 - Linux VM machine on S2, sync'd to AD1. No HyperV integration. AD1 and S1 have fine sync -- stripchart shows less than 100ms difference. S2 drifts like crazy. Here's a bit of the stripchart against AD1: 18:33:22 d:+00.0010138s o:+05.4101899s 18:33:24 d:+00.0010138s o:+05.4319765s 18:33:26 d:+00.0000000s o:+05.4788429s 18:33:28 d:+00.0000000s o:+05.6089942s 18:33:30 d:+00.0010138s o:+05.7240269s 18:33:32 d:+00.0000000s o:+06.0421911s 18:33:34 d:+00.0081104s o:+06.5613708s 18:33:37 d:+00.0000000s o:+06.9096594s 18:33:39 d:+00.0000000s o:+06.8867838s 18:33:41 d:+00.0010127s o:+06.8936401s In 20 seconds, it drifted over a second. If I manually reset it to within 1s, within a few minutes it'll be back drifting about 2 seconds. Overnight it went from ~2s to ~5s. The Linux VM inside S2 has perfect sync with AD1. Here's the config: C:\Users\mgg>w32tm /dumpreg /subkey:Parameters Value Name Value Type Value Data ------------------------------------------------------------ ServiceDll REG_EXPAND_SZ %systemroot%\system32\w32time.dll ServiceMain REG_SZ SvchostEntry_W32Time ServiceDllUnloadOnStop REG_DWORD 1 Type REG_SZ NT5DS NtpServer REG_SZ ad01.mydomain ad02.mydomain C:\Users\mgg>w32tm /dumpreg /subkey:Config Value Name Value Type Value Data ----------------------------------------------------------- FrequencyCorrectRate REG_DWORD 4 PollAdjustFactor REG_DWORD 5 LargePhaseOffset REG_DWORD 50000000 SpikeWatchPeriod REG_DWORD 900 LocalClockDispersion REG_DWORD 9 HoldPeriod REG_DWORD 5 PhaseCorrectRate REG_DWORD 1 UpdateInterval REG_DWORD 30000 EventLogFlags REG_DWORD 2 AnnounceFlags REG_DWORD 5 TimeJumpAuditOffset REG_DWORD 28800 MinPollInterval REG_DWORD 2 MaxPollInterval REG_DWORD 8 MaxNegPhaseCorrection REG_DWORD -1 MaxPosPhaseCorrection REG_DWORD -1 MaxAllowedPhaseOffset REG_DWORD 300 I looked at the event log, and apart from warnings about sync (after it gets way out of sync), there's no other warnings. How can I go about troubleshooting this? It's the only machine that is having this problem. All the other machines (physical and virtual) are doing fine. Edit: To clarify: The VM (AD1) has integration turned off and syncs to time.nist.gov. AD1 is fine. It's the physical machine S1 that can't sync to AD1 and drifts all over. All the other physical servers are able to sync to AD1 just fine. Update So, it appears to be an issue of running the VM. The clock slips slowly with the VM off. Turned on, it immediately starts losing seconds. I swt the VM to only use half the resources, and that seems to have slightly mitigated it, for now. Thanks!

    Read the article

  • Using group policy preferences to push a file to C:\Windows on a restricted user.

    - by Fireshot
    We have a really old Video learning program that we need to run from the network for our students. However it uses Director Player 6.0 and the students get the error: "Unable to copy the driver file C:\Windows\xobglu16.dll to your Windows directory. Your disk may be full" Now the solution I've read is to copy the files manually to each machine and mark them read-only. I'm trying to do this via GPP, but the Event log is showing an Access is denied error. I believe it is because the student accounts do not have permission to c:\windows. Any ideas on a work around without using a script?

    Read the article

  • win2008 r2 enterprise "Message Queuing" "Access is denied" "The list of messages cannot be retrieved"

    - by gerryLowry
    on my win7, I run compmgmt.msc and drill to a private queue folder ... when I click "Queue messages" or "Journal messages", I either see the messages, or "There are no items to show in this view". BUT, on win2008 R2 Enterprise, I run compmgmt.msc and drill to a private queue folder ... when I click "Queue messages" or "Journal messages", I see "There are no items to show in this view" which AFAIK is correct BUT I get this unwanted dialog: Message Queuing x ------------------------ (X) The list of messages cannot be retrieved. Error: Access is denied. [[ OK ]] On both computers, I'm a member of local Administrators. I'm concerned as a developer because I'm very soon going to be testing WCF/MSMQ software that works on my Win7 laptop. How to I get past this denied access problem? thnx / g.

    Read the article

  • Modify MDT wizard to automate computer naming

    - by Jeramy
    I originally posted this question to StackOverflow, but upon further consideration it might be more appropriate here. Situation: I am imaging new systems using MDT Lite-Touch. I am trying to customize the wizard to automate the naming of new systems so that they include a prefix "AG-", a department code which is selected from a drop-down box in the wizard page (eg. "COMM"), and finally the serial number of the computer being imaged, so that my result in this case would be "AG-COMM-1234567890" Status: I have banged away at this for a while but my Google searches have not turned up answers, my trial-and-error is not producing useful error messages and I think I am missing some fundamentals of how to get variables from the wizard page into the variables used by the lite-touch wizard. Progress: I first created the HTML page which I will include below and added a script to the page to concatenate the pieces into a variable called OSDComputername which, for testing, I could output in a msgbox and get to display correctly. The problem with this is I don't know how to trigger the script then assign it to the OSDComputername variable that is used throughout the rest of the Light-Touch process. I changed the script to a function and added it to DeployWiz_Initization.vbs then used the Initialization field in WDS to call it. I'll include the function below. The problem with this is I would get "Undefined Variable" for OSDComputername and I am not sure it is pulling the data from the HTML correctly. I tried adding the scripting into the customsettings.ini file after the "OSDComputername=" This resulted in the wizard just outputting my code in text as the computer name. I am now trying adding variables to "Properties=" (eg.DepartmentName) in the customsettings.ini, pulling thier value from the HTML Form and setting that value to the variable in my function in DeployWiz_Initization.vbs and calling them after "OSDComputername=" in the fashion "OSDComputername="AG-" & %DepartmentName%" in customsettings.ini I am rebuilding right now and will see how this goes Any help would be appreciated. The HTML page: <HTML> <H1>Configure the computer name.</H1> <span style="width: 95%;"> <p>Please answer the following questions. Your answers will be used to formulate the computer's name and description.</p> <FORM NAME="TestForm"> <p>Departmental Prefix: <!-- <label class=ErrMsg id=DepartmentalPrefix_Err>* Required (MISSING)</label> --> <SELECT NAME="DepartmentalPrefix_Edit" class=WideEdit> <option value="AADC">AADC</option> <option value="AEM">AEM</option> <option value="AIP">AIP</option> <option value="COM">COM</option> <option value="DO">DO</option> <option value="DSOC">DSOC</option> <option value="EDU">EDU</option> <option value="EPE">EPE</option> <option value="ITN">ITN</option> <option value="LA">LA</option> <option value="OAP">OAP</option> <option value="SML">SML</option> </SELECT> </p> <p><span class="Larger">Client's Net<u class=larger>I</u>D:</span> <INPUT NAME="ClientNetID" TYPE="TEXT" ID="ClientNetID" SIZE="15"></p> <p>Building: <!-- <label class=ErrMsg id=Building_Err>* Required (MISSING)</label> --> <SELECT NAME="Building_Edit" class=WideEdit> <option value="Academic Surge Facility A">Academic Surge Facility A</option> <option value="Academic Surge Facility B">Academic Surge Facility B</option> <option value="Caldwell">Caldwell</option> <option value="Kennedy">Kennedy</option> <option value="Roberts">Roberts</option> <option value="Warren">Warren</option> </SELECT> </p> <p> <span class="Larger">Room <u class=larger>N</u>umber:</span> <input type=text id="RoomNumber" name=RoomNumber size=15 /> </p> </FORM> </span> </HTML> The Function: Function SetComputerName OSDComputerName = "AG-" & oEnvironment.Item("DepartmentalPrefix_Edit") ComputerDescription = oEnvironment.Item("DepartmentalPrefix_Edit") & ", " & oEnvironment.Item("ClientNetID") & ", " & oEnvironment.Item("RoomNumber") & " " & oEnvironment.Item("Building_Edit") End Function

    Read the article

  • Windows SMTP Relay Server to add BCC to all emails

    - by faulty
    I'm looking for a Windows based SMTP Relay Server which allows me to add a specific BCC field to all outgoing emails that relayed through this server. The reason for such requirement is that we need to track if the email is actually sent. We're sending our email to end users via our cooperate email server. Currently we're receiving complaint that our end users did not receive our emails, but we don't have access to the email server's log. At the same time, our developers are using a specific library which doesn't allows adding BCC, or it's much more tedious to do so than replacing our SMTP Relay with one that add BCC. Currently we're using IIS' SMTP Server as our relay. Thanks.

    Read the article

  • How do I install the evaluation version of Windows Server 2012R2 VHD within a Windows Server 2008R2 Hyper-V system?

    - by Paul Hale
    I have a windows server 2008R2 running hyper-v. I have downloaded the Windows Server 2012RC DC Version from here... http://technet.microsoft.com/en-us/evalcenter/dn205286.aspx I am "forced" to install a download app that copy's a .vhd file to my chosen directory. The instructions on this page... http://technet.microsoft.com/library/dn303418.aspx say... To install the VHD Download the VHD file. Start Hyper-V Manager. On the Action menu, select Import Virtual Machine. Navigate to the directory that the virtual machine file was extracted to and select the directory (not the directory where the VHD file is located). Select the Copy the virtual machine option. Confirm that the import was successful by checking Hyper-V Manager. Configure the network adapter for the resulting virtual machine: right-click the virtual machine and select Settings. In the left pane, click Network Adapter. In the menu that appears, select one of the network adapters of the virtualization server, and then click OK. Start the virtual machine. Where it says "Navigate to the directory that the virtual machine file was extracted to and select the directory (not the directory where the VHD file is located). Select the Copy the virtual machine option." Well nothing has been extracted as far as I can tell? and if it has, I have no idea where or what im looking for? I tried creating a new VM and using the downloaded .vhd file but I got an error saying that the .vhd file is an incompatible format. Can anybody help me out please? Thanks, Paul

    Read the article

  • Why are group policy preference drive mappings not applied to the domain administrator account?

    - by Saariko
    I have a working policy on my entire domain. I just found out, when logging with the domain administrator, that this policy is not applied (EDIT: Running : gpresult shows that the GPO's are applied - but, this GPO is for Drive Mappings, and the actual drive mappings are NOT shown) The administrator account - does not have any login script on his profile tab. To note: The mappings were applied before the GPO with a login script using the : net use ... command - all was working perfectly and correctly for the domain administrator user as well - That removes sharing and security problem (IMO) My GPO's are mainly small/atomic settings: single GPO to handle each settings: UAC, Firewall, printers. GPO status for the object is enabled That's an overview of the Drive Maps: Reading on MS support site, I checked the delegation tab, and it is marked as applied to domain and enterprise admins. Every user gets these policies correctly. The OU that is set is the root of the domain. (for testing purpose - I did that to eliminate hierarchy issues - did not help) Block Inheritance is disabled. (never used it anyway) GPO link GPO Security Filterings

    Read the article

  • How do you setup FTP with IIS Manager Users in an NLB environment with shared IIS configs?

    - by William Jens
    I've setup a 2 node NLB cluster and used the following to share IIS configs between them. http://blogs.technet.com/b/meamcs/archive/2012/05/30/configuring-iis-7-5-shared-configuration.aspx The IIS configs and content is located on a network share via a UNC path. This works - updating IIS settings on one node, is visible in another node and my website works on the individual nodes and the cluster as whole. I'm able to setup an FTP site and successfully connect with my Windows login. However, I want to use IIS Manager Authentication as defined in: http://www.iis.net/learn/publish/using-the-ftp-service/configure-ftp-with-iis-manager-authentication-in-iis-7 I've tried using "Network Service" with the FTP COM object as well as a dedicated user account that exists on all three hosts, but every time I try to login with an IIS user I get something like the following: IISWMSVC_AUTHENTICATION_UNABLE_TO_READ_CONFIG An unexpected error occurred while retrieving the authentication information. Exception:System.Runtime.InteropServices.COMException (0x8007052E): Filename: Error: at Microsoft.Web.Administration.Interop.AppHostWritableAdminManager.GetAdminSection(String bstrSectionName, String bstrSectionPath) at Microsoft.Web.Administration.Configuration.GetSectionInternal(ConfigurationSection section, String sectionPath, String locationPath) at Microsoft.Web.Management.Server.ConfigurationAuthenticationProvider.GetSection(ServerManager serverManager) Process:dllhost User=NT AUTHORITY\NETWORK SERVICE Can anyone point me in the right direction here?

    Read the article