Search Results

Search found 3266 results on 131 pages for 'dell dimension'.

Page 33/131 | < Previous Page | 29 30 31 32 33 34 35 36 37 38 39 40  | Next Page >

  • What does 1080p mean in laptop resolution?

    - by Brian
    Dell is selling a laptop (Studio 15) where the options for screen resolution are 720p, 900p, and 1080p. What do they mean? I've found a Wikipedia entry that lists the old confusing (UXGA, WUXGA, &c) names and seems to indicate that 1080p might be 1920x1080. It has no information on 900p or 720p. Really, it was bad enough with the WUXGA style descriptions. I think vendors should tell you what they're selling. If you know what the screen resolutions are, I'd appreciate hearing it here.

    Read the article

  • How can I fix a computer that blue screens before Windows starts?

    - by Julio
    I have a Dell Inspiron running Windows 7 that keeps getting blue screens of death. At first, the computer slowed down so much it was unusable. After some time, it wouldn't even load Windows anymore; the machine just started going straight to a BSOD after the starting Windows logo. I have tried loading the reset disc, but it just takes me to a loading lobby and never advances. I don't need the files on the computer, but I do need the machine for school. What can I do?

    Read the article

  • Can I rebuild degraded RAID1 on a SAS 5 i controller with a larger mirror drive size?

    - by Kenny
    A drive failed on a Dell SAS 5i controller - see controller bios screengrab: http://imagebin.ca/view/SkZbszA.html The primary is a 160GB 10k sata drive. I added a 250GB 7k rpm drive in the hope that the array would rebuild onto this drive. This did not happen. (assuming that the controller would just operate at the speed of the slowest drive) The controller could see the new drive, but it didn't automatically rebuild the raid1 onto this drive. (my assumption is that it did not do this rebuild as the drive sizes are different). There was an option to add the new drive to the existing raid1 array - but when I tried this a message appeared stating that all data on the array would be lost. (I didn't get a screenshot of this message, I will later) Should the SAS 5i allow me to rebuild the array onto a larger drive? Is the option to add the drive to the array the right way to go? Many thanks!

    Read the article

  • Disable laptop screen

    - by Kyle
    I recently had the display fail on my Dell Inspiron E1505 laptop. I currently have my TV hooked up to the laptop's S-Video out which works fine as long as I'm running in Windows. For the first minute or so when the computer is booting I get no display. I was wondering if there was any way to disable the laptop screen entirely so that the TV display is active from the beginning (not just after Windows loads). I realize there may be a BIOS setting for this, my only problem is I can't see the BIOS settings screen since no display is active at that point so if anyone has any BIOS setting solutions I'd need the exact keystrokes to hit :)

    Read the article

  • Is There Anyway to Undo a Quick Initialize from a Perc6/i VD?

    - by Carlo71
    I stupidly fast initialized an existing Raid 5 Array Virtual disk with 10 Virtual Machines after creating a new Raid 5 Array. The VDs switched order on the list of the Perc Controller. My server is a PowerEdge R710 with a Perc 6/i Raid controller running ESXi 5.1. The Bios of the R710 and the Perc 6/i controller are both running the latest firmware. I tried the steps on this article: http://www.caseyfulton.com/dell-perc-6i-fast-initialize-how-to-restore/. However the BartPE just freezes on the Windows XP slapsh page. Does anybody know a full proof method? I have backups of the VMs, however I would like to avoid restoring all of them due to time constraint.

    Read the article

  • Getting around the lack of GPT support with CentOS 5.4

    - by sxanness
    Here is my issue and I hoping that there is someone out there that has an answer so I don't end up stuck here at my co-location all day. Last night I came here and upgraded a server (Dell 2970) to have four 1TB Hard Drives in RAID 5 which leaves a 3TB block. I tried to partition this but keep getting an error that GPT is not supported so I found a site online telling me I need to run the dd command and right random data to /dev/sda. This is great (if it works) but taking forever. I have two more machines to upgrade today and not a chair in site. Does anyone have advice on how I can avoid this issue beforehand? Thank You for your advice and support.

    Read the article

  • Cannot set MemOpMode or ProcVirtualization with syscfg.exe

    - by EGr
    When attempting to set MemOpMode or ProcVirtualization with syscfg.exe, I get the following error: C:\Users\EGr>syscfg --MemOpMode=AdvEccMode System Services or CSIOR disabled In the past, I have been told that this can be resolved by forcefully reinstalling the Dell Lifecycle controller firmware, and then trying again; however, I cannot find my notes on how to do that. Has anyone ever run into this issue, and does anyone know how I can fix it? If it is possible to forcefully reinstall the firmware, how would I do that? I've tried running the installer, but it fails after running for ~2 min. I believe there is a way to fix this as well, by adding/modifying a registry value at HKLM\System\Control\CurrentControlSet\Services\IPMIDRV (that might not be the correct path, but I know it is IPMIDRV). Is this a common issue? What is the actual cause of it?

    Read the article

  • Is this a graphics card failure?

    - by Alexander Lozada
    I own an older 32-bit Dell XPS 410 that I intended to use for gaming. Currently, I have a ATI Radeon 4000 series card installed, along with a Core 2 Duo and Ubuntu 12.10. I'm fairly certain that my problem is a GPU failure - but before I spend money on a new one, I want to make sure other components aren't the problem/if it would be cheaper just to buy a new PC. Here are my symptoms: Computer power button remains orange (usually green when successfully started.) A fan gets increasingly faster until powered off. Monitor remains black when started, receiving no signal. When powered on, the computer will power itself off near instantly, and then turn on again. If startup is successful, sometimes the screen will become jittered and unusable unless restarted. Is this just a GPU failure, or something more extensive like the motherboard?

    Read the article

  • How does RAM fail?

    - by ethanlee16
    I have an issue with a Dell Inspiron 15 (1545) laptop that refuses to open any applications (save select Microsoft programs, e.g. Security Essentials, Ctrl Panel, Windows Explorer (not Internet), regedit, Event Viewer, etc.). I've run Microsoft Memory Diagnostics Tool and it found a 'hardware problem was detected.' Does this indicate that the RAM has failed? I notice when I open programs like Word, Excel, Internet Explorer, etc., it always give me an error from WerFault.exe saying The instruction at xxxxxxx referenced memory at xxxxxxxxx. The memory could not be written. and sometimes something about illegal instructions. If it is a hardware problem, does this mean that replacing the RAM is my only option? Again, I would also like to know if RAM can fail (like hard drives) and if malware can cause RAM to fail also.

    Read the article

  • Replacing an ATA-100 hard drive

    - by Pieter
    I was instructed to replace the hard drive in an old laptop, a Dell Latitude D505. I'm suspecting that there was a head crash when someone moved the laptop while it was turned on. In the specifications, I found this about the hard drive: 30GB ATA-100; (4200RPM); 40GB ATA-100 (5400RPM); 60GB ATA-100 (4200RPM) *Optional 40GB (5400) 2nd HDD Module for media bay I'm familiar with SATA and IDE, but ATA-100 doesn't ring a bell. What do I have to take into account when I go look for a replacement hard drive?

    Read the article

  • Slight network lag on Small Business Server 2008 R2

    - by Sir.Nathan Stassen
    I recently upgraded a network from a SBS 2003 server to a SBS 2008 R2 Server. Both I and users have noticed a slight delay in network applications and browsing network drives on the new server. It is minor, maybe a second or two at most. However I am wondering if anyone knows of anyway to optimize the networking to service requests sooner to the workstations. The network is running a 1 gig network with some 100 meg devices (mainly network printers). All workstations are XP SP3 Network software runs out of a shared folder mapped as a network drive, no sql databases. Server is a Dell Poweredge T610 with plenty of ram, cpu power, and storage.

    Read the article

  • How to use auto-discovery with iDRAC Enterprise?

    - by jwiz
    All I want to do is: have "auto discovery" enabled on my iDRAC enterprise at the factory rack the server, cable iDRAC to dhcp-enabled management network have the iDRAC DHCP, find the "Provisioning Server", and get updated with login credentials (for us to use with racadm, idrac webui, etc.) I don't need to do any configuring of the system, install OS, or anything else. I just want idrac to dhcp out of the box, and end up with an account that can be used to login. All the docs I can find on Dell's site refer to a "Provisioning Server", but I honestly can't tell if they have some reference product, or if they only have software that "integrates" with other vendor's existing management systems. I'd be happy to set up whatever is needed, I just can't find something that explicitly describes the process (only references to the fact that it is supported).

    Read the article

  • Can I move a one drive RAID 0 array on a PERC 6 to another server?

    - by zippy
    We have a Dell Poweredge 2970 with a PERC 6/i RAID controller. We have a one drive RAID 0 array (we wanted to add the drive as a JBOD but the PERC forces you to create an array to access it from the PERC). Can we take the one drive RAID 0 and move it to a new server (one that doesn't have a PERC)? Since there's only one drive in the "array" there's no striping going on...the only issue would seem to be if the PERC has some metadata on the drive that would prevent Windows from reading it. Does anyone have any experience with this scenario?

    Read the article

  • Cannot login to OpenManage Server Administrator

    - by ejel
    After freshly installed OpenManage Server Administrator from the CD that comes with my new server, Dell PowerEdge T110, I still could not figure out how to login successfully to the application. The server is running Windows 2008 SR2 Foundation and serves as a domain controller. I access its web interface locally using Firefox 3.6. On the login page and choose local system login. OMSA user's guide seems to state that I should be able to login using an Active Directory user. I tried Administrator, my_domain\Administrator, a a few combinations with the correct password. But none of them can logged in. Does Server Administrator requires any additional treatment to the user accounts, or what are the steps I missed here?

    Read the article

  • Converting a Full HD Inspiron 9400 laptop LCD to a standalone monitor

    - by jhaukur
    Has anyone tried converting a LCD laptop monitor (17" full HD in this instance) to a stand-alone monitor? Are there any converters that one can buy to send DVI or VGA signals to the plug that is used to connect said LCD to the laptop motherboard? My laptop is the infamous Dell Inspiron 9400 (1705) model. They can have awesome monitors but if you check out ebay, there are many there for sale for little to nothing since the graphic cards fault unsually often in those machines. I'd like to be able to use the LCD and just scrap the rest.

    Read the article

  • Video issues with old server running Boxee

    - by Skaughty
    I have a old Dell Power Edge 1650 1U rackmount server running Windows XP. Dual 1.3 ghz Processors and 1 GB of RAM. I would like to run Boxee on it, but the 8mb integrated video card will not support it. The font within Boxee just comes up as blocks of color. I have a PCI Radion R9000 dual out video card. However when I plug it in I can not get video signal on any of the VGA outs. Is it possible to upgrade the video card on this old of a server, or is it possible to make it work with the older integrated video?

    Read the article

  • Can I rebuild degraded RAID1 on a SAS 5 i controller with a larger mirror drive size?

    - by Kenny
    Hi, A drive failed on a Dell SAS 5i controller - see controller bios screengrab: http://imagebin.ca/view/SkZbszA.html The primary is a 160GB 10k sata drive. I added a 250GB 7k rpm drive in the hope that the array would rebuild onto this drive. This did not happen. (assuming that the controller would just operate at the speed of the slowest drive) The controller could see the new drive, but it didn't automatically rebuild the raid1 onto this drive. (my assumption is that it did not do this rebuild as the drive sizes are different). There was an option to add the new drive to the existing raid1 array - but when I tried this a message appeared stating that all data on the array would be lost. (I didn't get a screenshot of this message, I will later) Should the SAS 5i allow me to rebuild the array onto a larger drive? Is the option to add the drive to the array the right way to go? Many thanks!

    Read the article

  • Upgrading drives on a MD3000

    - by Anonymouse
    Hello, Our MD3000 array is getting full as our databases are growing and we need more spaces. Currently, we use a MD3000 with a two-servers Windows 2003 cluster and 15x 73GB SAS drives. Disk groups are configured in RAID1 of two drives. The approach we are currently investigating is simply swapping the existing SAS drives with bigger ones (300GB instead of 73GB), one at a time, and let each RAID1 array rebuilt. Is it a good approach? Will we be able to resize the array afterwards? Will we be able to resize the partitions afterwards? Can the Dell M3000 Management software do it or will we have to bring the server offline and use some partition software to do it? Thanks in advance.

    Read the article

  • Suggestions for Troubleshooting WIndows 7 lockups

    - by Craig L
    I've got a Dell Latitude E6500 that was working fine under Vista x64. I got one of the new Seagate 500GB Hybrid SSD/HD 2.5 drives and thought.. hmm.. let's try Win 7 x64 on it. Bottom line: It works great for hours and then it will hard lock. I don't mean BSOD (or whatever the Win7 equivalent is). I mean my screen is displaying a static image (if there is a clock displayed, it will be frozen at the time the lockup occurred) and the mouse and keyboard do not work. Control-Alt-Delete will not work. I have to hold down the power button to reboot. The event log records NOTHING at the time the lockup occurs. Obviously something is happening to the system to cause the lockup, but the default Windows 7 x64 doesn't log it. How can I log the things Windows doesn't normally log in Event Viewer ?

    Read the article

  • Brand New MOnitor Won't Get Input From CPU

    - by HollerTrain
    I have an old Dell 2350. I found a HD a few months ago and plugged it in and it booted up. So I just purchased a monitor and plugged it in, and put the HD inside and connected the two connections (Bus, and a four pronged connector) and no signal is being sent to monitor. is this a monitor issue or the HD is just dead? HD is spinning. CPU is turned on :) Yet no signal.. any thoughts?

    Read the article

  • Secondary Monitor won't Display at Full Resolution with Primary Display Disconnected

    - by Laramie
    I have had a bad day. Among today's events, the LCD display on my Dell E6500 notebook failed. It had been working with a secondary monitor connected through a VGA cable at 1600x900 resolution until I removed the LCD from my notebook for repair. Now the max resolution available on the secondary display is 1024x768. If I reconnect the burned out primary display, the secondary monitor is again available at 1600x900. The video card is an onboard Mobil Intel 4. How can I maintain the secondary display at 1600x900 with the primary display disconnected (for repair)? Edit: I just noticed that when Windows boots, it displays at the correct resolution and I can see my desktop in all its glory for a couple seconds then reverts to 1024x768.

    Read the article

  • SATA drive not recognized when installing RHEL 5.1 on PowerEdge R410

    - by Rachel
    Here's my setup: Dell R410 with Perc S100 (software) raid controller on an Intel ICH10R chipset The first problem is that the Perc S100 is only supported on windows. I'm trying to install RHEL 5.1. It boots from the cdrom, but later the installer can't see the cdrom or hard drive. Both are connected to the on-board sata controller. The only options in the R410 bios for SATA are ATA or RAID. I don't need raid, I just want a single drive setup.

    Read the article

  • Looking for a laptop with a removable hard drive

    - by anno
    At the moment, I possess a Dell Inspiron 6400. Just removing two screws, I've made the drive removable (look here) and I can pull it off in one second. The new Inspiron and Studio laptops don't support this anymore (the drive is no more on the side but on the back of the laptop). So I’m looking for a new laptop having this kind of feature, or one that can be modded easily. I also need a : Screen = 15" (if possible resolution 1366 x 768 resolution) Core i5-520M Midrange GPU (like an ATI Mobility Radeon HD 5650) Decent battery life minimum fan noise Thanks.

    Read the article

  • Ubuntu PowerEdge T110

    - by Josh
    I just got a Dell PowerEdge T110 server. I moved the boot order to CD - HDD - NIC, then installed Ubuntu 10.10, Desktop Ed. I chose install alongside other OS (even though there was none), then chose use entire partition. It showed that Ubuntu would use 160 of the 160 available GB. It installed, updated (while installing), then said, need to eject and restart, as usual. It restarted, but to a blank screen. No output whatsoever. Not even BIOS. Just blank. The monitor isn't even woken from sleep. Power cycled, still doing it. Tested the monitor with a laptop, and it is fine. What on earth is going on here?

    Read the article

  • Intsalling Linux on PowerEdge R410 via USB

    - by Bill Johnson
    I’m hoping someone can help me with the following issue. I have a Dell PowerEdge R410 and basically the Optical Drive has failed when I have been given the server. I have installed 2 SATA drives and want to install Ubuntu 11.04; however, each time I have tried i.e. using bootable .iso on USB it failed. I assume it's failing as with a lot of releases they all look at the CD drive. Ubunutu has failed on installation with the error message unable to mount CD. I have tried installing Microsoft Hyper-v and that also fails as during installation it asks for CD/DVD drivers. Tried embedding ISO's from various distro's (Linux and Windows) with drivers and that hasn't worked out either. Does anyone have any idea on how I can get Ubuntu on this server? Should I look towards an old distro perhaps?

    Read the article

< Previous Page | 29 30 31 32 33 34 35 36 37 38 39 40  | Next Page >