  • Dual head setup for Ubuntu 10.04.1 and Windows XP Pro with same hardware configuration

    - by mejpark
    Hello. I have a Dell OptiPlex 360 workstation at work, with 2 x ATI RV280 [Radeon 9200 PRO] graphics cards installed, which are attached to two identical 19" HII flat panel monitors. I'm using the open source Radeon driver with Ubuntu, and the proprietary drivers with Windows. The good news is that dual head configuration works for both OSes. The bad news is, I have to use a different hardware configuration for each OS to achieve this. Hardware config #1: Dual monitors work for Windows XP Pro like this: First display -> external VGA port Second display -> DVI input on gfx card Hardware config #2: Dual monitors work for Ubuntu 10.04.1 like this: First display -> VGA port on gfx card Second display -> DVI input on gfx card I connected up the displays according to Config #2 and booted up Windows, which resulted in a mirror image on both screens. I was unable to login, as the login box was not visible. I unplugged the VGA lead from gfx card and plugged it into the external VGA port (Config #1) - Windows dual head works again, but the VGA-connected screen is not recognised by Ubuntu and remains in standby mode. Is it possible to configure a dual head setup for Ubuntu using Config #1, or am I missing something? I tried setting up dual monitors using Config #1, this morning which didn't work. By default, there is no xorg.conf file in Ubuntu 10.04.1, so I generated one using: $ sudo X :2 -configure X.Org X Server 1.7.6 Release Date: 2010-03-17 X Protocol Version 11, Revision 0 Build Operating System: Linux 2.6.24-27-server i686 Ubuntu Current Operating System: Linux harrier 2.6.32-24-generic #42-Ubuntu SMP Fri Aug 20 14:24:04 UTC 2010 i686 Kernel command line: BOOT_IMAGE=/boot/vmlinuz-2.6.32-24-generic root=UUID=a34c1931-98d4-4a34-880c-c227a2936c4a ro quiet splash Build Date: 21 July 2010 12:47:34PM xorg-server 2:1.7.6-2ubuntu7.3 (For technical support please see http://www.ubuntu.com/support) Current version of pixman: 0.16.4 Before reporting problems, check http://wiki.x.org to make sure that you have the latest version. Markers: (--) probed, (**) from config file, (==) default setting, (++) from command line, (!!) notice, (II) informational, (WW) warning, (EE) error, (NI) not implemented, (??) unknown. (==) Log file: "/var/log/Xorg.2.log", Time: Mon Sep 13 10:02:02 2010 List of video drivers: apm ark intel mach64 s3virge trident mga tseng ati nouveau neomagic i740 openchrome voodoo s3 i128 radeon siliconmotion nv ztv vmware v4l chips rendition savage sisusb tdfx geode sis r128 cirrus fbdev vesa (++) Using config file: "/home/michael/xorg.conf.new" (==) Using config directory: "/usr/lib/X11/xorg.conf.d" (II) [KMS] No DRICreatePCIBusID symbol, no kernel modesetting. Xorg detected your mouse at device /dev/input/mice. Please check your config if the mouse is still not operational, as by default Xorg tries to autodetect the protocol. Xorg has configured a multihead system, please check your config. Your xorg.conf file is /home/michael/xorg.conf.new To test the server, run 'X -config /home/michael/xorg.conf.new' ddxSigGiveUp: Closing log $ sudo X -config /home/michael/xorg.conf.new Fatal server error: Server is already active for display 0 If this server is no longer running, remove /tmp/.X0-lock and start again. Please consult the The X.Org Foundation support at http://wiki.x.org for help. ddxSigGiveUp: Closing log I then booted Ubuntu in failsafe mode, dropped into root shell, and executed $ X -config /home/michael/xorg.conf.new again. The screen went blank and turned off, so I reset the machine. There must be a way round this. Any help to set up a dual head config for Ubuntu using Config #1 would be hugely appreciated. TIA, Mike

    Read the article

  • Splitting a raidctl mirror safely

    - by milkfilk
    I have a Sun T5220 server with the onboard LSI card and two disks that were in a RAID 1 mirror. The data is not important right now but we had a failed disk and are trying to understand how to do this for real if we had to recover from a failure. The initial situation looked like this: # raidctl -l c1t0d0 Volume Size Stripe Status Cache RAID Sub Size Level Disk ---------------------------------------------------------------- c1t0d0 136.6G N/A DEGRADED OFF RAID1 0.1.0 136.6G GOOD N/A 136.6G FAILED Green light on the 0.0.0 disk. Find / lights up the 0.1.0 disk. So I know I have a bad drive and which one it is. Server still boots obviously. First, we tried putting a new disk in. This disk came from an unknown source. Format would not see it, cfgadm -al would not see it so raidctl -l would not see it. I figure it's bad. We tried another disk from another spare server: # raidctl -c c1t1d0 c1t0d0 (where t1 is my good disk - 0.1.0) Disk has occupied space. Also the different syntax options don't change anything: # raidctl -C "0.1.0 0.0.0" -r 1 1 Disk has occupied space. # raidctl -C "0.1.0 0.0.0" 1 Disk has occupied space. Ok. Maybe this is because the disk from the spare server had a RAID 1 on it already. Aha, I can see another volume in raidctl: # raidctl -l Controller: 1 Volume:c1t1d0 (this is my server's root mirror) Volume:c1t132d0 (this is the foreign root mirror) Disk: 0.0.0 Disk: 0.1.0 ... No problem. I don't care about the data, I'll just delete the foreign mirror. # raidctl -d c1t132d0 (warning about data deletion but it works) At this point, /usr/bin/ binaries freak out. By that I mean, ls -l /usr/bin/which shows 1.4k but cat /usr/bin/which gives me a newline. Great, I just blew away the binaries (ie: binaries in mem still work)? I bounce the box. It all comes back fine. WTF. Anyway, back to recreating my mirror. # raidctl -l Controller: 1 Volume:c1t1d0 (this is my server's root mirror) Disk: 0.0.0 Disk: 0.1.0 ... Man says that you can delete a mirror and it will split it. Ok, I'll delete the root mirror. # raidctl -d c1t0d0 Array in use. (this might not be the exact error) I googled this and found of course you can't do this (even with -f) while booted off the mirror. Ok. I boot cdrom -s and deleted the volume. Now I have one disk that has a type of "LSI-Logical-Volume" on c1t1d0 (where my data is) and a brand new "Hitachi 146GB" on c1t0d0 (what I'm trying to mirror to): (booted off the CD) # raidctl -c c1t1d0 c1t0d0 (man says it's source destination for mirroring) Illegal Array Layout. # raidctl -C "0.1.0 0.0.0" -r 1 1 (alt syntax per man) Illegal Array Layout. # raidctl -C "0.1.0 0.0.0" 1 (assumes raid1, no help) Illegal Array Layout. Same size disks, same manufacturer but I did delete the volume instead of throwing in a blank disk and waiting for it to resync. Maybe this was a critical error. I tried selecting the type in format for my good disk to be a plain 146gb disk but it resets the partition table which I'm pretty sure would wipe the data (bad if this was production). Am I boned? Anyone have experience with breaking and resyncing a mirror? There's nothing on Google about "Illegal Array Layout" so here's my contrib to the search gods.

    Read the article

  • TS-7800 Hangs on bootup

    - by Reid
    I have a TS-7800, and it typically boots from the SD card inserted in it. When I tried to boot it up today, it hung on the syslog line. I am now having "Read only file system" problems. What has gone wrong? Bootup console: >> Copyright (c) 2008, Technologic Systems >> Booting from SD card... . . . . >> Booting to SD Card... INIT: version 2.86 booting Starting the hotplug events dispatcher: udevd. Synthesizing the initial hotplug events...done. Waiting for /dev to be fully populated...done. mount: can't find / in /etc/fstab or /etc/mtab Cleaning up ifupdown...rm: cannot remove `/etc/network/run/ifstate': Read-only file system Loading kernel modules...done. Checking all file systems... fsck 1.37 (21-Mar-2005) ... done. none on /dev/pts type devpts (rw,gid=5,mode=620) /etc/init.d/rcS: line 39: /tmp/.clean: Read-only file system Setting up networking...done. Setting up IP spoofing protection: rp_filter. Enabling packet forwarding...done. Configuring network interfaces...ifup: failed to open statefile /etc/network/run/ifstate: Read-only file system done. Starting portmap daemon: portmap. /etc/init.d/rcS: line 39: /tmp/.clean: Read-only file system /etc/init.d/rcS: line 24: /var/run/utmp: Read-only file system rm: cannot remove `/var/lib/urandom/random-seed': Read-only file system urandom start: failed. Recovering nvi editor sessions... done. INIT: Entering runlevel: 3 Starting system log daemon: syslogd . Starting kernel log daemon: klogd. Starting MTA: open: Read-only file system touch: cannot touch `/var/lib/exim4/config.autogenerated.tmp': Read-only file system chown: cannot access `/var/lib/exim4/config.autogenerated.tmp': No such file or directory chmod: cannot access `/var/lib/exim4/config.autogenerated.tmp': No such file or directory chmod: changing permissions of `/var/lib/exim4/config.autogenerated': Read-only file system /usr/sbin/update-exim4.conf: line 260: cannot create temp file for here document: Read-only file system /usr/sbin/update-exim4.conf: line 387: /var/lib/exim4/config.autogenerated.tmp: Read-only file system 2002-01-01 01:31:36 Cannot open main log file "/var/log/exim4/mainlog": Read-only file system: euid=0 egid=0 2002-01-01 01:31:36 non-existent configuration file(s): /var/lib/exim4/config.autogenerated.tmp 2002-01-01 01:31:36 Cannot open main log file "/var/log/exim4/mainlog": Read-only file system: euid=0 egid=0 exim: could not open panic log - aborting: see message(s) above Invalid new configfile /var/lib/exim4/config.autogenerated.tmp not installing /var/lib/exim4/config.autogenerated.tmp to /var/lib/exim4/config.autogenerated Starting internet superserver: inetd. Starting OpenBSD Secure Shell server: sshd. Starting NFS common utilities: statdStarting periodic command scheduler: cron/usr/sbin/cron: can't open or create /var/run/crond.pid: Read-only file system . Starting web server (apache2)...(30)Read-only file system: apache2: could not open error log file /var/log/apache2/error.log. Unable to open logs failed! Debian GNU/Linux 3.1 ts7800 ttyS0 ts7800 login:

    Read the article

  • Useful Command-line Commands on Windows

    - by Sung Meister
    The aim for this Wiki is to promote using a command to open up commonly used applications without having to go through many mouse clicks - thus saving time on monitoring and troubleshooting Windows machines. Answer entries need to specify Application name Commands Screenshot (Optional) Shortcut to commands && - Command Chaining %SYSTEMROOT%\System32\rcimlby.exe -LaunchRA - Remote Assistance (Windows XP) appwiz.cpl - Programs and Features (Formerly Known as "Add or Remove Programs") appwiz.cpl @,2 - Turn Windows Features On and Off (Add/Remove Windows Components pane) arp - Displays and modifies the IP-to-Physical address translation tables used by address resolution protocol (ARP) at - Schedule tasks either locally or remotely without using Scheduled Tasks bootsect.exe - Updates the master boot code for hard disk partitions to switch between BOOTMGR and NTLDR cacls - Change Access Control List (ACL) permissions on a directory, its subcontents, or files calc - Calculator chkdsk - Check/Fix the disk surface for physical errors or bad sectors cipher - Displays or alters the encryption of directories [files] on NTFS partitions cleanmgr.exe - Disk Cleanup clip - Redirects output of command line tools to the Windows clipboard cls - clear the command line screen cmd /k - Run command with command extensions enabled color - Sets the default console foreground and background colors in console command.com - Default Operating System Shell compmgmt.msc - Computer Management control.exe /name Microsoft.NetworkAndSharingCenter - Network and Sharing Center control keyboard - Keyboard Properties control mouse(or main.cpl) - Mouse Properties control sysdm.cpl,@0,3 - Advanced Tab of the System Properties dialog control userpasswords2 - Opens the classic User Accounts dialog desk.cpl - opens the display properties devmgmt.msc - Device Manager diskmgmt.msc - Disk Management diskpart - Disk management from the command line dsa.msc - Opens active directory users and computers dsquery - Finds any objects in the directory according to criteria dxdiag - DirectX Diagnostic Tool eventvwr - Windows Event Log (Event Viewer) explorer . - Open explorer with the current folder selected. explorer /e, . - Open explorer, with folder tree, with current folder selected. F7 - View command history find - Searches for a text string in a file or files findstr - Find a string in a file firewall.cpl - Opens the Windows Firewall settings fsmgmt.msc - Shared Folders fsutil - Perform tasks related to FAT and NTFS file systems ftp - Transfers files to and from a computer running an FTP server service getmac - Shows the mac address(es) of your network adapter(s) gpedit.msc - Group Policy Editor gpresult - Displays the Resultant Set of Policy (RSoP) information for a target user and computer httpcfg.exe - HTTP Configuration Utility iisreset - To restart IIS InetMgr.exe - Internet Information Services (IIS) Manager 7 InetMgr6.exe - Internet Information Services (IIS) Manager 6 intl.cpl - Regional and Language Options ipconfig - Internet protocol configuration lusrmgr.msc - Local Users and Groups Administrator msconfig - System Configuration notepad - Notepad? ;) mmsys.cpl - Sound/Recording/Playback properties mode - Configure system devices more - Displays one screen of output at a time mrt - Microsoft Windows Malicious Software Removal Tool mstsc.exe - Remote Desktop Connection nbstat - displays protocol statistics and current TCP/IP connections using NBT ncpa.cpl - Network Connections netsh - Display or modify the network configuration of a computer that is currently running netstat - Network Statistics net statistics - Check computer up time net stop - Stops a running service. net use - Connects a computer to or disconnects a computer from a shared resource, or displays information about computer connections odbcad32.exe - ODBC Data Source Administrator pathping - A traceroute that collects detailed packet loss stats perfmon - Opens Reliability and Performance Monitor ping - Determine whether a remote computer is accessible over the network powercfg.cpl - Power management control panel applet quser - Display information about user sessions on a terminal server qwinsta - See disconnected remote desktop sessions reg.exe - Console Registry Tool for Windows regedit - Registry Editor rasdial - Connects to a VPN or a dialup network robocopy - Backup/Restore/Copy large amounts of files reliably rsop.msc - Resultant Set of Policy (shows the combined effect of all group policies active on the current system/login) runas - Run specific tools and programs with different permissions than the user's current logon provides sc - Manage anything you want to do with services. schtasks - Enables an administrator to create, delete, query, change, run and end scheduled tasks on a local or remote system. secpol.msc - Local Security Settings services.msc - Services control panel set - Displays, sets, or removes cmd.exe environment variables. set DIRCMD - Preset dir parameter in cmd.exe start - Starts a separate window to run a specified program or command start. - opens the current directory in the Windows Explorer. shutdown.exe - Shutdown or Reboot a local/remote machine subst.exe - Associates a path with a drive letter, including local drives systeminfo -Displays a comprehensive information about the system taskkill - terminate tasks by process id (PID) or image name tasklist.exe - List Processes on local or a remote machine taskmgr.exe - Task Manager telephon.cpl - Telephone and Modem properties timedate.cpl - Date and Time title - Change the title of the CMD window you have open tracert - Trace route wmic - Windows Management Instrumentation Command-line winver.exe - Find Windows Version wscui.cpl - Windows Security Center wuauclt.exe - Windows Update AutoUpdate Client

    Read the article

  • Determining cause of high NFS/IO utilization without iotop

    - by Matt
    I have a server that is doing an NFSv4 export for user's home directories. There are roughly 25 users (mostly developers/analysts) and about 40 servers mounting the home directory export. Performance is miserable, with users often seeing multi-second lags for simple commands (like ls, or writing a small text file). Sometimes the home directory mount completely hangs for minutes, with users getting "permission denied" errors. The hardware is a Dell R510 with dual E5620 CPUs and 8 GB RAM. There are eight 15k 2.5” 600 GB drives (Seagate ST3600057SS) configured in hardware RAID-6 with a single hot spare. RAID controller is a Dell PERC H700 w/512MB cache (Linux sees this as a LSI MegaSAS 9260). OS is CentOS 5.6, home directory partition is ext3, with options “rw,data=journal,usrquota”. I have the HW RAID configured to present two virtual disks to the OS: /dev/sda for the OS (boot, root and swap partitions), and /dev/sdb for the home directories. What I find curious, and suspicious, is that the sda device often has very high utilization, even though it only contains the OS. I would expect this virtual drive to be idle almost all the time. The system is not swapping, according to "free" and "vmstat". Why would there be major load on this device? Here is a 30-second snapshot from iostat: Time: 09:37:28 AM Device: rrqm/s wrqm/s r/s w/s rkB/s wkB/s avgrq-sz avgqu-sz await svctm %util sda 0.00 44.09 0.03 107.76 0.13 607.40 11.27 0.89 8.27 7.27 78.35 sda1 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 sda2 0.00 44.09 0.03 107.76 0.13 607.40 11.27 0.89 8.27 7.27 78.35 sdb 0.00 2616.53 0.67 157.88 2.80 11098.83 140.04 8.57 54.08 4.21 66.68 sdb1 0.00 2616.53 0.67 157.88 2.80 11098.83 140.04 8.57 54.08 4.21 66.68 dm-0 0.00 0.00 0.03 151.82 0.13 607.26 8.00 1.25 8.23 5.16 78.35 dm-1 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 dm-2 0.00 0.00 0.67 2774.84 2.80 11099.37 8.00 474.30 170.89 0.24 66.84 dm-3 0.00 0.00 0.67 2774.84 2.80 11099.37 8.00 474.30 170.89 0.24 66.84 Looks like iotop is the ideal tool to use to sniff out these kinds of issues. But I'm on CentOS 5.6, which doesn't have a new enough kernel to support that program. I looked at Determining which process is causing heavy disk I/O?, and besides iotop, one of the suggestions said to do a "echo 1 /proc/sys/vm/block_dump". I did that (after directing kernel messages to tempfs). In about 13 minutes I had about 700k reads or writes, roughly half from kjournald and the other half from nfsd: # egrep " kernel: .*(READ|WRITE)" messages | wc -l 768439 # egrep " kernel: kjournald.*(READ|WRITE)" messages | wc -l 403615 # egrep " kernel: nfsd.*(READ|WRITE)" messages | wc -l 314028 For what it's worth, for the last hour, utilization has constantly been over 90% for the home directory drive. My 30-second iostat keeps showing output like this: Time: 09:36:30 PM Device: rrqm/s wrqm/s r/s w/s rkB/s wkB/s avgrq-sz avgqu-sz await svctm %util sda 0.00 6.46 0.20 11.33 0.80 71.71 12.58 0.24 20.53 14.37 16.56 sda1 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 sda2 0.00 6.46 0.20 11.33 0.80 71.71 12.58 0.24 20.53 14.37 16.56 sdb 137.29 7.00 549.92 3.80 22817.19 43.19 82.57 3.02 5.45 1.74 96.32 sdb1 137.29 7.00 549.92 3.80 22817.19 43.19 82.57 3.02 5.45 1.74 96.32 dm-0 0.00 0.00 0.20 17.76 0.80 71.04 8.00 0.38 21.21 9.22 16.57 dm-1 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 dm-2 0.00 0.00 687.47 10.80 22817.19 43.19 65.48 4.62 6.61 1.43 99.81 dm-3 0.00 0.00 687.47 10.80 22817.19 43.19 65.48 4.62 6.61 1.43 99.82

    Read the article

  • broadcom 5722 NIC not installed on Ubuntu Server, although driver present

    - by Bastien
    Hello, I just installed Ubuntu Server 10.04 LTS, running kernel 2.6.32-24-server, on a brand new Dell T110 server, supposedly fully compatible with Ubuntu Server. I have two NICs: one ONBOARD, the other additional on PCI. both of them are Broadcom netXtreme 5572. on the first boot of the system, I could see both cards as eth0 and eth1 (with ifconfig) I configured eth0 as static IP (as planned), and did not configure eth1. after rebooting, one of the two NICs "disappeared": it does not appear in ifconfig at all. the one that disappeared is the ONBOARD one. I investigated a bit and found the following things: the card is SEEN, but not "installed", it appears as "UNCLAIMED" in lshw: *-network UNCLAIMED description: Ethernet controller product: NetXtreme BCM5722 Gigabit Ethernet PCI Express vendor: Broadcom Corporation physical id: 0 bus info: pci@0000:04:00.0 version: 00 width: 64 bits clock: 33MHz capabilities: pm vpd msi pciexpress cap_list configuration: latency=0 resources: memory:df9f0000-df9fffff *-network description: Ethernet interface product: NetXtreme BCM5722 Gigabit Ethernet PCI Express vendor: Broadcom Corporation physical id: 0 bus info: pci@0000:05:00.0 logical name: eth0 version: 00 serial: 00:10:18:60:23:64 size: 100MB/s capacity: 1GB/s width: 64 bits clock: 33MHz capabilities: pm vpd msi pciexpress bus_master cap_list ethernet physical tp 10bt 10bt-fd 100bt 100bt-fd 1000bt 1000bt-fd autonegotiation configuration: autonegotiation=on broadcast=yes driver=tg3 driverversion=3.102 duplex=full firmware=5722-v3.09 ip=10.129.167.25 latency=0 link=yes multicast=yes port=twisted pair speed=100MB/s resources: irq:35 memory:dfaf0000-dfafffff so I checked my dmesg and found a few strange lines, showing, there actually is a problem bringing up this card: [ 3.737506] tg3: Could not obtain valid ethernet address, aborting. [ 3.737527] tg3 0000:04:00.0: PCI INT A disabled [ 3.737535] tg3: probe of 0000:04:00.0 failed with error -22 [ 3.737553] alloc irq_desc for 17 on node -1 [ 3.737555] alloc kstat_irqs on node -1 [ 3.737560] tg3 0000:05:00.0: PCI INT A -> GSI 17 (level, low) -> IRQ 17 [ 3.737566] tg3 0000:05:00.0: setting latency timer to 64 [ 3.793529] eth0: Tigon3 [partno(BCM95722A2202G) rev a200] (PCI Express) MAC address 00:10:18:60:23:64 [ 3.793532] eth0: attached PHY is 5722/5756 (10/100/1000Base-T Ethernet) (WireSpeed[1]) [ 3.793534] eth0: RXcsums[1] LinkChgREG[0] MIirq[0] ASF[0] TSOcap[1] [ 3.793536] eth0: dma_rwctrl[76180000] dma_mask[64-bit] that actually shows that one NIC is recognized, the other is not. I researched a bit more, with lspci -v: 04:00.0 Ethernet controller: Broadcom Corporation NetXtreme BCM5722 Gigabit Ethernet PCI Express Subsystem: Broadcom Corporation NetXtreme BCM5722 Gigabit Ethernet PCI Express Flags: fast devsel, IRQ 16 Memory at df9f0000 (64-bit, non-prefetchable) [size=64K] Capabilities: [48] Power Management version 3 Capabilities: [50] Vital Product Data <?> Capabilities: [58] Vendor Specific Information <?> Capabilities: [e8] Message Signalled Interrupts: Mask- 64bit+ Queue=0/0 Enable- Capabilities: [d0] Express Endpoint, MSI 00 Capabilities: [100] Advanced Error Reporting <?> Capabilities: [13c] Virtual Channel <?> Capabilities: [160] Device Serial Number 00-00-00-fe-ff-00-00-00 Kernel modules: tg3 05:00.0 Ethernet controller: Broadcom Corporation NetXtreme BCM5722 Gigabit Ethernet PCI Express Subsystem: Broadcom Corporation NetXtreme BCM5722 Gigabit Ethernet PCI Express Flags: bus master, fast devsel, latency 0, IRQ 35 Memory at dfaf0000 (64-bit, non-prefetchable) [size=64K] Expansion ROM at <ignored> [disabled] Capabilities: [48] Power Management version 3 Capabilities: [50] Vital Product Data <?> Capabilities: [58] Vendor Specific Information <?> Capabilities: [e8] Message Signalled Interrupts: Mask- 64bit+ Queue=0/0 Enable+ Capabilities: [d0] Express Endpoint, MSI 00 Capabilities: [100] Advanced Error Reporting <?> Capabilities: [13c] Virtual Channel <?> Capabilities: [160] Device Serial Number 64-23-60-fe-ff-18-10-00 Capabilities: [16c] Power Budgeting <?> Kernel driver in use: tg3 Kernel modules: tg3 here I could see that the MAC address is 00-00-00-FE-FF-00-00-00, which, according to some forum posts on several websites, could be an issue. I've researched everything I could on the net, and found out several people having slightly comparable issues, but they usually involve different HW, and do not provide a proper explanation / solution... I would appreciate if anyone around here has some info to share ! thanks

    Read the article

  • Why do GPUs overheat?

    - by JAD
    About a year ago, I added a 9800GT (1 GB version) and a Corsair CX500 PSU to an HP M8000N computer. A few weeks ago, the HDD overheated and I decided to transfer the GPU & PSU to a new build, which consists of: i3 @ 3.3Ghz Gigabyte H61 Micro ATX Mobo 4GB RAM 500GB WD HDD DVD RW Drive Cooler Master Elite 430 Tower Once I had Win7 up and running, I installed all the essential drivers that came with the Gigabyte Mobo CD. However, whenever I tried installing the Graphics Media Accelerator driver, the computer would crash and enter an endless boot sequence on the next startup. I skipped installing this driver and installed the CD driver for the 9800GT, which by now is a year old. Everything was working fine, WEI rated my GPU at 6.6 graphics & aero performance. However, after updating my Nvidia drivers to the latest, the WEI dropped my rating to 3.3 for Aero, and 4.7 for graphics performance. Just to make sure that everything was ok, I ran Bad Company 2 on medium settings. The first few minutes ran just fine at a smooth framerate, so I dismissed this as Windows being Windows. About 6 hours later, I ran BC2 again. This time I averaged anywhere from 2-5 FPS. I checked the GPU temperature through GPU-Z, and it came back as 120C. The problem with this, is that the computer was on for six hours up to that point. Wouldn't the card have experienced a reactor core meltdown a lot sooner than that? Granted, the computer was "sleeping" some of the time, but still... The next day I took out a temperature gun and ran some tests. I would point the laser at a very specific area on the reverse side of the card (not the fan or "front"), and compare the temp reading with GPU-Z. After leaving the system on idle on idle for a few minutes, I ran BC2 twice. Here are the results: GPU-Z Reading / Temp Gun Reading / Time Null / 22.3°C / Comp is Off 53°C / 33.5°C / 1:49 78°C / 46°C / 1:53 - (First BC2 run; good framerate) 102°C / 64.6°C / 2:01 - (System is again on idle) 113°C / 64.8°C / 2:10 119°C / 71.8°C / 2:17 - (Second BC2 run; poor framerate) I should also mention that I also took a temp recording of another part of the GPU from 2:01-2:17. The temp in this area jumped from 75°C to 82.9°C in that time frame. This pretty much confirms that GPU-Z is reporting the temperature accurately, and the card is overheating. But I'd like to know why; the cars is doing nothing and still the temperature climbs at a steady rate. I thoroughly cleaned the GPU and PSU when I salvaged them from the old HP M8000N computer with a can of compressed air, dust cant be the issue. Similarly, the rest of the computer is brand new. I installed various Nvidia drivers, but no luck. It seems strange to me that a year-old card is suddenly failing on me; aren't they supposed to last at least two years? Could this be a driver issue? Is the motherboard faulty? Could the PSU be overfeeding the card on voltage? Neither case seems likely, as the CPU, RAM and otherwise the rest of the comp has worked flawlessly and has stayed well within respectable temp ranges (the i3 lingers around 50C, the HDD stays at 30C, so does the PSU). How can I pinpoint the issue?

    Read the article

  • Cloudformation with Ubuntu throwing errors

    - by Sammaye
    I have been doing some reading and have come to the understanding that if you wish to use a launchConfig with Ubuntu you will need to install the cfn-init file yourself which I have done: "Properties" : { "KeyName" : { "Ref" : "KeyName" }, "SpotPrice" : "0.05", "ImageId" : { "Fn::FindInMap" : [ "AWSRegionArch2AMI", { "Ref" : "AWS::Region" }, { "Fn::FindInMap" : [ "AWSInstanceType2Arch", { "Ref" : "InstanceType" }, "Arch" ] } ] }, "SecurityGroups" : [ { "Ref" : "InstanceSecurityGroup" } ], "InstanceType" : { "Ref" : "InstanceType" }, "UserData" : { "Fn::Base64" : { "Fn::Join" : ["", [ "#!/bin/bash\n", "apt-get -y install python-setuptools\n", "easy_install https://s3.amazonaws.com/cloudformation-examples/aws-cfn-bootstrap-1.0-6.tar.gz\n", "cfn-init ", " --stack ", { "Ref" : "AWS::StackName" }, " --resource LaunchConfig ", " --configset ALL", " --access-key ", { "Ref" : "WorkerKeys" }, " --secret-key ", {"Fn::GetAtt": ["WorkerKeys", "SecretAccessKey"]}, " --region ", { "Ref" : "AWS::Region" }, " || error_exit 'Failed to run cfn-init'\n" ]]}} But I have a problem with this setup that I cannot seem to get a decent answer to. I keep getting this error in the logs: Jun 15 12:02:34 ip-0 [CLOUDINIT] __init__.py[DEBUG]: config-scripts-per-once already ran once Jun 15 12:02:34 ip-0 [CLOUDINIT] __init__.py[DEBUG]: handling scripts-per-boot with freq=None and args=[] Jun 15 12:02:34 ip-0 [CLOUDINIT] __init__.py[DEBUG]: handling scripts-per-instance with freq=None and args=[] Jun 15 12:02:34 ip-0 [CLOUDINIT] __init__.py[DEBUG]: handling scripts-user with freq=None and args=[] Jun 15 12:02:34 ip-0 [CLOUDINIT] cc_scripts_user.py[WARNING]: failed to run-parts in /var/lib/cloud/instance/scripts Jun 15 12:02:34 ip-0 [CLOUDINIT] __init__.py[WARNING]: Traceback (most recent call last):#012 File "/usr/lib/python2.7/dist-packages/cloudinit/CloudConfig/__init__.py", line 117, in run_cc_modules#012 cc.handle(name, run_args, freq=freq)#012 File "/usr/lib/python2.7/dist-packages/cloudinit/CloudConfig/__init__.py", line 78, in handle#012 [name, self.cfg, self.cloud, cloudinit.log, args])#012 File "/usr/lib/python2.7/dist-packages/cloudinit/__init__.py", line 326, in sem_and_run#012 func(*args)#012 File "/usr/lib/python2.7/dist-packages/cloudinit/CloudConfig/cc_scripts_user.py", line 31, in handle#012 util.runparts(runparts_path)#012 File "/usr/lib/python2.7/dist-packages/cloudinit/util.py", line 223, in runparts#012 raise RuntimeError('runparts: %i failures' % failed)#012RuntimeError: runparts: 1 failures Jun 15 12:02:34 ip-0 [CLOUDINIT] __init__.py[ERROR]: config handling of scripts-user, None, [] failed Jun 15 12:02:34 ip-0 [CLOUDINIT] __init__.py[DEBUG]: handling keys-to-console with freq=None and args=[] Jun 15 12:02:34 ip-0 [CLOUDINIT] __init__.py[DEBUG]: handling phone-home with freq=None and args=[] Jun 15 12:02:34 ip-0 [CLOUDINIT] __init__.py[DEBUG]: handling final-message with freq=None and args=[] Jun 15 12:02:34 ip-0 [CLOUDINIT] cloud-init-cfg[ERROR]: errors running cloud_config [final]: ['scripts-user'] I have absolutely no idea what scripts-user means and Google is not helping much here either. I can, when I ssh into the server, see that it runs the userdata script since I can access cfn-init as a command whereas I cannot in the original AMI the instance is made from. However I have a launchConfig: "Comment" : "Install a simple PHP application", "AWS::CloudFormation::Init" : { "configSets" : { "ALL" : ["WorkerRole"] }, "WorkerRole" : { "files" : { "/etc/cron.d/worker.cron" : { "content" : "*/1 * * * * ubuntu /home/ubuntu/worker_cron.php &> /home/ubuntu/worker.log\n", "mode" : "000644", "owner" : "root", "group" : "root" }, "/home/ubuntu/worker_cron.php" : { "content" : { "Fn::Join" : ["", [ "#!/usr/bin/env php", "<?php", "define('ROOT', dirname(__FILE__));", "const AWS_KEY = \"", { "Ref" : "WorkerKeys" }, "\";", "const AWS_SECRET = \"", { "Fn::GetAtt": ["WorkerKeys", "SecretAccessKey"]}, "\";", "const QUEUE = \"", { "Ref" : "InputQueue" }, "\";", "exec('git clone x '.ROOT.'/worker');", "if(!file_exists(ROOT.'/worker/worker_despatcher.php')){", "echo 'git not downloaded right';", "exit();", "}", "echo 'git downloaded';", "include_once ROOT.'/worker/worker_despatcher.php';" ]]}, "mode" : "000755", "owner" : "ubuntu", "group" : "ubuntu" } } } } Which does not seem to run at all. I have checked for the files existance in my home directory and it's not there. I have checked for the cronjob entry and it's not there either. I cannot, after reading through the documentation, seem to see what's potentially wrong with my code. Any thoughts on why this is not working? Am I missing something blatant?

    Read the article

  • How to get rid of a stubborn 'removed' device in mdadm

    - by T.J. Crowder
    One of my server's drives failed and so I removed the failed drive from all three relevant arrays, had the drive swapped out, and then added the new drive to the arrays. Two of the arrays worked perfectly. The third added the drive back as a spare, and there's an odd "removed" entry in the mdadm details. I tried both mdadm /dev/md2 --remove failed and mdadm /dev/md2 --remove detached as suggested here and here, neither of which complained, but neither of which had any effect, either. Does anyone know how I can get rid of that entry and get the drive added back properly? (Ideally without resyncing a third time, I've already had to do it twice and it takes hours. But if that's what it takes, that's what it takes.) The new drive is /dev/sda, the relevant partition is /dev/sda3. Here's the detail on the array: # mdadm --detail /dev/md2 /dev/md2: Version : 0.90 Creation Time : Wed Oct 26 12:27:49 2011 Raid Level : raid1 Array Size : 729952192 (696.14 GiB 747.47 GB) Used Dev Size : 729952192 (696.14 GiB 747.47 GB) Raid Devices : 2 Total Devices : 2 Preferred Minor : 2 Persistence : Superblock is persistent Update Time : Tue Nov 12 17:48:53 2013 State : clean, degraded Active Devices : 1 Working Devices : 2 Failed Devices : 0 Spare Devices : 1 UUID : 2fdbf68c:d572d905:776c2c25:004bd7b2 (local to host blah) Events : 0.34665 Number Major Minor RaidDevice State 0 0 0 0 removed 1 8 19 1 active sync /dev/sdb3 2 8 3 - spare /dev/sda3 If it's relevant, it's a 64-bit server. It normally runs Ubuntu, but right now I'm in the data centre's "rescue" OS, which is Debian 7 (wheezy). The "removed" entry was there the last time I was in Ubuntu (it won't, currently, boot from the disk), so I don't think that's not some Ubuntu/Debian conflict (and they are, of course, closely related). Update: Having done extensive tests with test devices on a local machine, I'm just plain getting anomalous behavior from mdadm with this array. For instance, with /dev/sda3 removed from the array again, I did this: mdadm /dev/md2 --grow --force --raid-devices=1 And that got rid of the "removed" device, leaving me just with /dev/sdb3. Then I nuked /dev/sda3 (wrote a file system to it, so it didn't have the raid fs anymore), then: mdadm /dev/md2 --grow --raid-devices=2 ...which gave me an array with /dev/sdb3 in slot 0 and "removed" in slot 1 as you'd expect. Then mdadm /dev/md2 --add /dev/sda3 ...added it — as a spare again. (Another 3.5 hours down the drain.) So with the rebuilt spare in the array, given that mdadm's man page says RAID-DEVICES CHANGES ... When the number of devices is increased, any hot spares that are present will be activated immediately. ...I grew the array to three devices, to try to activate the "spare": mdadm /dev/md2 --grow --raid-devices=3 What did I get? Two "removed" devices, and the spare. And yet when I do this with a test array, I don't get this behavior. So I nuked /dev/sda3 again, used it to create a brand-new array, and am copying the data from the old array to the new one: rsync -r -t -v --exclude 'lost+found' --progress /mnt/oldarray/* /mnt/newarray This will, of course, take hours. Hopefully when I'm done, I can stop the old array entirely, nuke /dev/sdb3, and add it to the new array. Hopefully, it won't get added as a spare!

    Read the article

  • PC: Quick Freeze, then BSOD, then forced reboot, then freezes again

    - by cr0z3r
    Lately I have been experiencing a weird issue. My PC will hang for a second and then BSOD - it stays there, so I have to reboot. Once Windows starts again and I'm logged in, after 1-10min it freezes again, this time without BSOD. RECAP: 1 second freeze BSOD, hangs there I have to force-reboot Once PC rebooted, I log back into Windows second freeze between a 1-10min range, no BSOD (alternatively, I get a freeze with a constant sound/noise, no BSOD) I contacted my PC provider, who told me my graphics-card might be flawed (Quadro 4000), so I used a Quadro 2000 that they lend me. The issue still occurred. The issue now seemed to belong to a flawed RAM module. Following my provider's steps, I removed all but the first from the left column and kept using my PC for a week or so without any issues. I then added the bottom-right module, and so on, until all modules were back inside - I had no problems. Now it seemed that a simple take-out-put-back-in of the RAM modules had fixed the issue. However, after a few months, the issue was back. I redid all the RAM-swapping I had done before, and concluded that the lower-right module was flawed. My provider changed it for another, and everything was great until now. My PC froze again for barely a second, hanged on a BSOD, I rebooted it, logged-in to Windows to get a freeze (without BSOD or reboot) 40 seconds later. Something worth noting, is that every time I reboot after the BSOD, it is something within Chrome that freezes my PC (e.g. this time I clicked the "restore" button as Chrome mentioned it had exited unexpectedly - from the previous freeze obviously - and it instantly froze). Finally, the Event Viewer lists 2 critical events in the past hour as "ID: 41, Type: Kernel-Power". PC-Specs: http://i.imgur.com/VZpbr.jpg Previous Dump-files: https://dl.dropbox.com/u/716600/DumpFiles_08_2012.zip I would like to thank anybody in advance for your help. You're great. UPDATE 1: I realized that I did not mention an awkward fact about this issue. After I have gotten the 1-sec freeze followed by a BSOD, after I rebooted because the BSOD hanged, and after I logged back in to get another (this time, eternal) freeze and rebooted once again, the PC does not boot back up. The power-light is on, but my monitor says "no signal", as if the PC wouldn't really be turned on. This truly seems a like a power-related issue, doesn't it? UPDATE 2: I just got a freeze, but without BSOD. My screen froze (while on Chrome, which is starting to seem suspicious to me) with an ongoing sound/noise. I had to force-reboot my PC. I would say this is a graphics-card issue, but this issue also happened when I was using the Quadro 2000 from my provider. UPDATE 3: I just got a BSOD while trying to render something (quite heavy, actually) in 3ds Max 2012. I left the BSOD "running", as it said it was writing dump files to disk. However, the percentage number stayed at 0, so after 15 minutes I force-rebooted. I then used the software WhoCrashed (thank you Dave) which reported the following from the C:\Windows\Memory.dmp file: On Thu 22.11.2012 22:13:45 GMT your computer crashed crash dump file: C:\Windows\memory.dmp uptime: 01:05:27 This was probably caused by the following module: Unknown () Bugcheck code: 0x124 (0x0, 0xFFFFFA80275AC028, 0xF200001F, 0x100B2) Error: WHEA_UNCORRECTABLE_ERROR Bug check description: This bug check indicates that a fatal hardware error has occurred. This bug check uses the error data that is provided by the Windows Hardware Error Architecture (WHEA). This is likely to be caused by a hardware problem problem. This problem might be caused by a thermal issue. A third party driver was identified as the probable root cause of this system error. It is suggested you look for an update for the following driver: Unknown . Google query: Unknown WHEA_UNCORRECTABLE_ERROR

    Read the article

  • ESXI guests not using available CPU resources

    - by Alan M
    I have a VMWare ESXI 5.0.0 (it's a bit old, I know) host with three guest VMs on it. For reasons unknown, the guests will not use much of the availble CPU resources. I have all three guests in a single pool, with the hosts all configured to use the same amount of resource shares, so they're basically 33% each. The three guests are basically identically configured as far as their VM resources go. So the problem is, even when the guests are performing what should be very 'busy' activitites, such as at bootup, the actual host CPU consumed is something tiny, like 33mhz, when seen via vSphere console's "Virtual Machines" tab when viewing properties for the pool. And of course, the performance of the guest VMs is terrible. The host has plenty of CPU to spare. I've tried tinkering with individual guest VM resource settings; cranking up the reservation, etc. No matter. The guests just refuse to make use of the abundant CPU available to them, and insist on using a sliver of the available resources. Any suggestions? Update after reading various comments below Per the suggestions below, I did remove the guests from the application pool; this didn't make any difference. I do understand that the guests are not going to consume resources they do not need. I have tried to do a remote perfmon on the guest which is experiencing long boot times, but I cannot connect to the guest remotely with perfmon (guest is w2k8r2 server). Host graphs for CPU, Mem, Disk are basically flatlining; very little demand. Same is true for the guest stats; while the guest itself seems to be crawling, the guest resource graphing shows very little activity across CPU, Mem, Disk. Host is a Dell PowerEdge 2900, has 2 physical CPU,20gb RAM. (it's a test/dev environment using surplus gear) Guest1 has: VM ver. 7, 2vCPU, 4gb RAM, 140gb storage which lives on a RAID-5 array on the host. Guest2 has: VM ver. 7, 2vCPU, 4gb RAM, 140gb storage which lives on a RAID-5 array on the host. Guest3 has: VM ver. 7, 1vCPU, 2gb RAM, 2tb storage which lives on a RAID-5 ISCSI NAS box Perhaps I am making a false assumption that if a guest has a demand for CPU (e.g. Windows Task Manager shows 100% CPU), the host would supply the guest with more CPU (mem, disk) on demand. Another Update After checking the stats, it would appear that the host is indeed not busy at all, neither is the guest. I believe I have a good idea on the issue, though; a messed-up VMWare Tools install. The guest has VMware Tools on it, but the host says it does not. VMWare Tools refuses to uninstall, refuses to be upgraded, refuses to be recognized. While I cannot say with authority, this would appear to be something worth investigation. I do not know the origin of the guest itself, nor the specifics on the original VMWare Tools install. Following various bits of googling, I did come up with a few suggestions that went nowhere. To that end, I was going to delete this question, but was prompted not to do so since so many folks answered. My suspicion right now is; the problem truly is the guest; the guest is not making a demand on the host, and as a natural result, the host is treating the guest accordingly. My Final Update I am 99% certain the guest VM had something fundamentally wrong with it re VMWare Tools. I created a clone of a different VM with a near-identical OS config, but a properly working install of VMWare tools. The guest runs just great, and takes up it's allotment of resources when it needs to; e.g. it eats up about 850mhz CPU during startup, then ticks down to idle once the guest OS is stable.

    Read the article

  • Riak "error":"insufficient_vnodes_available"

    - by Wolfiem
    We have 4 nodes Riak installation. They are running on Ubuntu 12.04 LTS Precise installed servers. We have installed 1.1.4 at August 1st 2012 and upgraded 1.2.0 when its available. Server names are: f1 - 10.10.0.12 - This is the first installed server. We have joined other ones to this server. This also serves Riak control. s2 - 10.10.0.22 - s3 - 10.10.0.23 - s4 - 10.10.0.24 - This server also serves Riak control. This morning we've seen "insufficient nodes available" error at our applications log and restarted all nodes. 3 of them became available except "f1" UPDATE : while I prepare this message live 3 nodes became unavailable and need restart Riak. wolfiem@f01:~$ sudo /etc/init.d/riak start Riak failed to start within 15 seconds, see the output of 'riak console' for more information. If you want to wait longer, set the environment variable WAIT_FOR_ERLANG to the number of seconds to wait. I've tried to set WAIT_FOR_ERLANG value to 60 seconds but I can't. adding this line in vm.args didn't work: -env WAIT_FOR_ERLANG 60 I also tried to set this from terminal but it didn't work either. wolfiem@f01:~$ export WAIT_FOR_ERLANG=60 It still says "Riak failed to start within 15 seconds" This is the console.log output: 2012-09-11 10:58:02.532 [info] <0.7.0> Application lager started on node '[email protected]' 2012-09-11 10:58:02.560 [warning] <0.148.0>@riak_core_ring_manager:reload_ring:231 No ring file available. 2012-09-11 10:58:02.585 [error] <0.164.0> CRASH REPORT Process <0.164.0> with 0 neighbours exited with reason: eaddrnotavail in gen_server:init_it/6 line 320 This is the error.log output 2012-09-11 10:58:02.585 [error] <0.164.0> CRASH REPORT Process <0.164.0> with 0 neighbours exited with reason: eaddrnotavail in gen_server:init_it/6 line 320 This is the crash.log output: 2012-09-11 10:58:02 =CRASH REPORT==== crasher: initial call: mochiweb_socket_server:init/1 pid: <0.164.0> registered_name: [] exception exit: {eaddrnotavail,[{gen_server,init_it,6,[{file,"gen_server.erl"},{line,320}]},{proc_lib,init_p_do_apply,3,[{file,"proc_lib.erl"},{line,227}]}]} ancestors: [riak_core_sup,<0.135.0>] messages: [] links: [<0.136.0>] dictionary: [] trap_exit: true status: running heap_size: 377 stack_size: 24 reductions: 403 neighbours: You can find the riak console output below: wolfiem@f01:~$ riak console Attempting to restart script through sudo -H -u riak Exec: /usr/lib/riak/erts-5.9.1/bin/erlexec -boot /usr/lib/riak/releases/1.2.0/riak -embedded -config /etc/riak/app.config -pa /usr/lib/riak/basho-patches -args_file /etc/riak/vm.args -- console Root: /usr/lib/riak Erlang R15B01 (erts-5.9.1) [source] [64-bit] [smp:8:8] [async-threads:64] [kernel-poll:true] =INFO REPORT==== 11-Sep-2012::10:44:18 === alarm_handler: {set,{system_memory_high_watermark,[]}} ** /usr/lib/riak/lib/observer-1.1/ebin/etop_txt.beam hides /usr/lib/riak/lib/basho-patches/etop_txt.beam ** Found 1 name clashes in code paths 10:44:19.099 [info] Application lager started on node '[email protected]' 10:44:19.130 [warning] No ring file available. 10:44:19.158 [error] CRASH REPORT Process <0.164.0> with 0 neighbours exited with reason: eaddrnotavail in gen_server:init_it/6 line 320 /usr/lib/riak/lib/os_mon-2.2.9/priv/bin/memsup: Erlang has closed. =INFO REPORT==== 11-Sep-2012::10:44:19 === alarm_handler: {clear,system_memory_high_watermark} Erlang has closed {"Kernel pid terminated",application_controller,"{application_start_failure,riak_core,{shutdown,{riak_core_app,start,[normal,[]]}}}"} Crash dump was written to: /var/log/riak/erl_crash.dump Kernel pid terminated (application_controller) ({application_start_failure,riak_core,{shutdown,{riak_core_app,start,[normal,[]]}}})

    Read the article

  • Cannot read status the monit daemon, even with allowed group

    - by jefflunt
    I cannot seem to get monit status or other CLI commands to work. I've built monit v5.8 to run on a Raspberry Pi. I'm able to add services to be monitored, and the web interface can be accessed just fine, as I've set it up for public read-only access (it's a test server, not my final production setup, so not a big deal right now). Problem is, when I run monit status while logged in as root I get: # monit status monit: cannot read status from the monit daemon I also have monit started on boot via this /etc/inittab file entry: mo:2345:respawn:/usr/local/bin/monit -Ic /etc/monitrc I've verified that monit is running, and I'm getting email alerts anytime I either kill the monit process manually, or reboot my raspberry pi. So, next I check my monitrc file permissions to see which group is allowed access. # ls -al /etc/monitrc -rw------- 1 root root 2359 Aug 24 14:48 /etc/monitrc Here's my relevant allow section of the control file. set httpd port 80 allow [omitted] readonly allow @root allow localhost allow 0.0.0.0/0.0.0.0 Also tried setting permissions on this file to 640 to allow group read permissions, but no matter what I try I either get the same error as noted above, or when the permissions are set to 640 I get: # monit status monit: The control file '/etc/monitrc' must have permissions no more than -rwx------ (0700); right now permissions are -rw-r----- (0640). What am I missing here? I know that the httpd must be enabled, as that's the interface that the CLI uses to get information (or so I've read), so I've done that. And in terms of monit doing its monitoring job and sending email alerts, that's all working as well. Here's my entire monitrc file - again, this is version v5.8, and it was build with both PAM and SSL support. The process runs under the root user: # Global settings set daemon 300 with start delay 5 set logfile /var/log/monit.log set pidfile /var/run/monit.pid set idfile /var/run/.monit.id set statefile /var/run/.monit.state # Mail alerts ## Set the list of mail servers for alert delivery. Multiple servers may be ## specified using a comma separator. If the first mail server fails, Monit # will use the second mail server in the list and so on. By default Monit uses # port 25 - it is possible to override this with the PORT option. # set mailserver smtp.gmail.com port 587 username [omitted] password [omitted] using tlsv1 ## Send status and events to M/Monit (for more informations about M/Monit ## see http://mmonit.com/). By default Monit registers credentials with ## M/Monit so M/Monit can smoothly communicate back to Monit and you don't ## have to register Monit credentials manually in M/Monit. It is possible to ## disable credential registration using the commented out option below. ## Though, if safety is a concern we recommend instead using https when ## communicating with M/Monit and send credentials encrypted. # # set mmonit http://monit:[email protected]:8080/collector # # and register without credentials # Don't register credentials # # ## Monit by default uses the following format for alerts if the the mail-format ## statement is missing:: set mail-format { from: [email protected] subject: $SERVICE $DESCRIPTION message: $EVENT Service: $SERVICE Date: $DATE Action: $ACTION Host: $HOST Description: $DESCRIPTION Monit instance provided by chicagomeshnet.com } # Web status page set httpd port 80 allow [omitted] readonly allow @root allow localhost allow 0.0.0.0/0.0.0.0 ## You can set alert recipients whom will receive alerts if/when a ## service defined in this file has errors. Alerts may be restricted on ## events by using a filter as in the second example below.

    Read the article

  • NIC Bonding/balance-rr with Dell PowerConnect 5324

    - by Branden Martin
    I'm trying to get NIC bonding to work with balance-rr so that three NIC ports are combined, so that instead of getting 1 Gbps we get 3 Gbps. We are doing this on two servers connected to the same switch. However, we're only getting the speed of one physical link. We are using 1 Dell PowerConnect 5324, SW version 2.0.1.3, Boot version 1.0.2.02, HW version 00.00.02. Both servers are CentOS 5.9 (Final) running OnApp Hypervisor (CloudBoot) Server 1 is using ports g5-g7 in port-channel 1. Server 2 is using ports g9-g11 in port-channel 2. Switch show interface status Port Type Duplex Speed Neg ctrl State Pressure Mode -------- ------------ ------ ----- -------- ---- ----------- -------- ------- g1 1G-Copper -- -- -- -- Down -- -- g2 1G-Copper Full 1000 Enabled Off Up Disabled Off g3 1G-Copper -- -- -- -- Down -- -- g4 1G-Copper -- -- -- -- Down -- -- g5 1G-Copper Full 1000 Enabled Off Up Disabled Off g6 1G-Copper Full 1000 Enabled Off Up Disabled Off g7 1G-Copper Full 1000 Enabled Off Up Disabled On g8 1G-Copper Full 1000 Enabled Off Up Disabled Off g9 1G-Copper Full 1000 Enabled Off Up Disabled On g10 1G-Copper Full 1000 Enabled Off Up Disabled On g11 1G-Copper Full 1000 Enabled Off Up Disabled Off g12 1G-Copper Full 1000 Enabled Off Up Disabled On g13 1G-Copper -- -- -- -- Down -- -- g14 1G-Copper -- -- -- -- Down -- -- g15 1G-Copper -- -- -- -- Down -- -- g16 1G-Copper -- -- -- -- Down -- -- g17 1G-Copper -- -- -- -- Down -- -- g18 1G-Copper -- -- -- -- Down -- -- g19 1G-Copper -- -- -- -- Down -- -- g20 1G-Copper -- -- -- -- Down -- -- g21 1G-Combo-C -- -- -- -- Down -- -- g22 1G-Combo-C -- -- -- -- Down -- -- g23 1G-Combo-C -- -- -- -- Down -- -- g24 1G-Combo-C Full 100 Enabled Off Up Disabled On Flow Link Ch Type Duplex Speed Neg control State -------- ------- ------ ----- -------- ------- ----------- ch1 1G Full 1000 Enabled Off Up ch2 1G Full 1000 Enabled Off Up ch3 -- -- -- -- -- Not Present ch4 -- -- -- -- -- Not Present ch5 -- -- -- -- -- Not Present ch6 -- -- -- -- -- Not Present ch7 -- -- -- -- -- Not Present ch8 -- -- -- -- -- Not Present Server 1: cat /etc/sysconfig/network-scripts/ifcfg-eth3 DEVICE=eth3 HWADDR=00:1b:21:ac:d5:55 USERCTL=no BOOTPROTO=none ONBOOT=yes MASTER=onappstorebond SLAVE=yes cat /etc/sysconfig/network-scripts/ifcfg-eth4 DEVICE=eth4 HWADDR=68:05:ca:18:28:ae USERCTL=no BOOTPROTO=none ONBOOT=yes MASTER=onappstorebond SLAVE=yes cat /etc/sysconfig/network-scripts/ifcfg-eth5 DEVICE=eth5 HWADDR=68:05:ca:18:28:af USERCTL=no BOOTPROTO=none ONBOOT=yes MASTER=onappstorebond SLAVE=yes cat /etc/sysconfig/network-scripts/ifcfg-onappstorebond DEVICE=onappstorebond IPADDR=10.200.52.1 NETMASK=255.255.0.0 GATEWAY=10.200.2.254 NETWORK=10.200.0.0 USERCTL=no BOOTPROTO=none ONBOOT=yes cat /proc/net/bonding/onappstorebond Ethernet Channel Bonding Driver: v3.4.0-1 (October 7, 2008) Bonding Mode: load balancing (round-robin) MII Status: up MII Polling Interval (ms): 100 Up Delay (ms): 0 Down Delay (ms): 0 Slave Interface: eth3 MII Status: up Speed: 1000 Mbps Duplex: full Link Failure Count: 0 Permanent HW addr: 00:1b:21:ac:d5:55 Slave Interface: eth4 MII Status: up Speed: 1000 Mbps Duplex: full Link Failure Count: 0 Permanent HW addr: 68:05:ca:18:28:ae Slave Interface: eth5 MII Status: up Speed: 1000 Mbps Duplex: full Link Failure Count: 0 Permanent HW addr: 68:05:ca:18:28:af Server 2: cat /etc/sysconfig/network-scripts/ifcfg-eth3 DEVICE=eth3 HWADDR=00:1b:21:ac:d5:a7 USERCTL=no BOOTPROTO=none ONBOOT=yes MASTER=onappstorebond SLAVE=yes cat /etc/sysconfig/network-scripts/ifcfg-eth4 DEVICE=eth4 HWADDR=68:05:ca:18:30:30 USERCTL=no BOOTPROTO=none ONBOOT=yes MASTER=onappstorebond SLAVE=yes cat /etc/sysconfig/network-scripts/ifcfg-eth5 DEVICE=eth5 HWADDR=68:05:ca:18:30:31 USERCTL=no BOOTPROTO=none ONBOOT=yes MASTER=onappstorebond SLAVE=yes cat /etc/sysconfig/network-scripts/ifcfg-onappstorebond DEVICE=onappstorebond IPADDR=10.200.53.1 NETMASK=255.255.0.0 GATEWAY=10.200.3.254 NETWORK=10.200.0.0 USERCTL=no BOOTPROTO=none ONBOOT=yes cat /proc/net/bonding/onappstorebond Ethernet Channel Bonding Driver: v3.4.0-1 (October 7, 2008) Bonding Mode: load balancing (round-robin) MII Status: up MII Polling Interval (ms): 100 Up Delay (ms): 0 Down Delay (ms): 0 Slave Interface: eth3 MII Status: up Speed: 1000 Mbps Duplex: full Link Failure Count: 0 Permanent HW addr: 00:1b:21:ac:d5:a7 Slave Interface: eth4 MII Status: up Speed: 1000 Mbps Duplex: full Link Failure Count: 0 Permanent HW addr: 68:05:ca:18:30:30 Slave Interface: eth5 MII Status: up Speed: 1000 Mbps Duplex: full Link Failure Count: 0 Permanent HW addr: 68:05:ca:18:30:31 Here are the results of iperf. ------------------------------------------------------------ Client connecting to 10.200.52.1, TCP port 5001 TCP window size: 27.7 KByte (default) ------------------------------------------------------------ [ 3] local 10.200.3.254 port 53766 connected with 10.200.52.1 port 5001 [ ID] Interval Transfer Bandwidth [ 3] 0.0-10.0 sec 950 MBytes 794 Mbits/sec

    Read the article

  • Error installing mysql, any way to fix it?

    - by user156355
    I was installing mysql with apt-get install mysql-server (like I always did) before that I had done an apt-get update (I am using Debian 6), and when I installed I found this problem, pretty common as I see, but Ive followed all stepts and nothing have worked, Ive tried with apt-get install -f also with apt-get remove mysql-server (and common, and mysql-server-5.1) and also with apt-get purge (every packate) and later install, but nothing... I tried also dpkg-reconfigure mysql-server-5.1 apt-get install --reinstall mysql-server (all runed as Root) Still, nothing worked, any idea??? 130130 10:11:48 InnoDB: Shutdown completed; log sequence number 0 44233 Starting MySQL database server: mysqld . . . . . . . . . . . . . . failed! invoke-rc.d: initscript mysql, action "start" failed. dpkg: error processing mysql-server-5.1 (--configure): subprocess installed post-installation script returned error exit status 1 configured to not write apport reports dpkg: dependency problems prevent configuration of mysql-server: mysql-server depends on mysql-server-5.1; however: Package mysql-server-5.1 is not configured yet. dpkg: error processing mysql-server (--configure): dependency problems - leaving unconfigured configured to not write apport reports Errors were encountered while processing: mysql-server-5.1 mysql-server E: Sub-process /usr/bin/dpkg returned an error code (1) when I tried dpkg-reconfigure mysql-server-5.1 /usr/sbin/dpkg-reconfigure: mysql-server-5.1 is broken or not fully installed the case "Start" on /etc/init.d/mysql is 'start') sanity_checks; # Start daemon log_daemon_msg "Starting MySQL database server" "mysqld" if mysqld_status check_alive nowarn; then log_progress_msg "already running" log_end_msg 0 else # Could be removed during boot test -e /var/run/mysqld || install -m 755 -o mysql -g root -d /var/run/mysqld # Start MySQL! /usr/bin/mysqld_safe > /dev/null 2>&1 & # 6s was reported in #352070 to be too few when using ndbcluster for i in 1 2 3 4 5 6 7 8 9 10 11 12 13 14; do sleep 1 if mysqld_status check_alive nowarn ; then break; fi log_progress_msg "." done if mysqld_status check_alive warn; then log_end_msg 0 # Now start mysqlcheck or whatever the admin wants. output=$(/etc/mysql/debian-start) [ -n "$output" ] && log_action_msg "$output" else log_end_msg 1 log_failure_msg "Please take a look at the syslog" fi fi When I make mysql force-reload: Reloading MySQL database server: mysqld/usr/bin/mysqladmin: connect to server at 'localhost' failed error: 'Can't connect to local MySQL server through socket '/var/run/mysqld/mysqld.sock' (2)' Check that mysqld is running and that the socket: '/var/run/mysqld/mysqld.sock' exists! root@americandougnuts:/etc/init.d# root@americandougnuts:/etc/init.d# Check that mysqld is running and that the socket: '/var/run/mysqld/mysqld.sock' exists!

    Read the article

  • WDS DHCP same server on Windows Server 2008

    - by Richard
    I have been struggling with a problem on my Windows Server 2008 for the past 4 - 5 hours and cannot figure out whats wrong. I have tried pretty much everything that I found on google and all the links are purple. Hopefully you guys can help me. I am running a Windows Server 2008 Standard edition with the latest updates as of today. Furthermore I am running a Windows Server 2003. Both are virtual machines on my ESXi 5 server. My network is: 192.168.10.0/24 W2k8: 192.168.10.251 is the PDC running ADS, DHCP and WDS W2k3: 192.168.10.253 AND 192.168.1.175 running Routing and Remote Access and ISA 2006 Enterprise In my internal network (192.168.10.0/24) I have my client machine (192.168.10.10) that runs a VMWare Workstation. I am trying to deploy Windows 7 Home Premium to a virtual machine on my VMWorkstation via PXE. I have set the Workstation's VM network adapter to "bridged" so that it uses the physical network adapter and is connected to my internal network. The DHCP pool is configured to give IP addresses from 192.168.10.10-192.168.10.15 (works for normal clients and is not used up) When I start my VM with the PXE I get the error: PXE-E52:proxyDHCP offers were received. No DHCP offers were received Apperently this means "that means that WDS responded but the DHCP server did not." People suggested to direct the traffic to both WDS and DHCP on the router, since everything is on the same subnet there is no need for that as the broadcast is seen by everyone (WDS and DHCP) No reservation for the virtual mac addrs is made on the DHCP. Furthermore it was suggested to configure the DHCP options: Option 60= PXEClient Option 66= WDS server name or IP address Option 67= Boot file name However, this is not recommended by Microsoft, I tried it and it did not solve my problem. The configuration on the WDS (My System is German therefore the actual naming might be different): PXE response tab: PXE responses is set to "ALL (known and unknown)" DHCP Tab: Do not listen to port 67 is NOT ticked - if I tick this I do not get any responses and the PXE errors gets PXE-E51 that neither DHCP or proxyDHCP were received DHCP-Option 60 for "PXEClient" is ticked The confusing part here is that it is advised in the tab to tick the first option since it is on the same server. Network Configuration Tab: Use the following IP-Address range for Multicast-IP-Address: 224.0.1.0 - 224.0.10.0 Thats not the default one, however it is in the allowed range. The UDP port range is the default since it is not advised to change them. I tried to change the "networkprofile" from 100mbits/1gbits and custom. I am running a 1gbit network with CAT6 cables and 1gbit netgear switch 5 ports. Everything is configured to use 1gbit. The WDS is authorised for the DHCP server. My ISA 2006 configuration: For the internal networking i have configured the following policy array: Allow protocols on internal network including the w2k3 host: 67,68,53,ICMP, 4011 UDP receive, 64001-6500 UDP send receive, 69 UDP send Routing and Remote Access I tried the DHCP relay agent configuration that was suggested as well, but that did not work I would highly appreciate anykind of help because I am pretty much done here with my nerves. Thank you very much in advance.

    Read the article

  • MySQL 5.5 (Percona) assertion failure log.. what would cause this?

    - by Tom Geee
    256GB, 64 Core , AMD running Ubuntu 12.04 with Percona MySQL 5.5.28. Below is the assertion failure. We just had a second assertion failure (different "in file", position, etc) while running a large set of inserts. After the first failure, MySQL restarted after a reboot only - after continuously looping on the same error after trying to recover. I decided to do a mysqlcheck with -o for optimize. Since these are all Innodb tables (very large tables, 60+GB) this would do an alter table on all tables. In the middle of this , the below assertion failure happened again: 121115 22:30:31 InnoDB: Assertion failure in thread 140086589445888 in file btr0pcur.c line 452 InnoDB: Failing assertion: btr_page_get_prev(next_page, mtr) == buf_block_get_page_no(btr_pcur_get_block(cursor)) InnoDB: We intentionally generate a memory trap. InnoDB: Submit a detailed bug report to http://bugs.mysql.com. InnoDB: If you get repeated assertion failures or crashes, even InnoDB: immediately after the mysqld startup, there may be InnoDB: corruption in the InnoDB tablespace. Please refer to InnoDB: http://dev.mysql.com/doc/refman/5.5/en/forcing-innodb-recovery.html InnoDB: about forcing recovery. 03:30:31 UTC - mysqld got signal 6 ; This could be because you hit a bug. It is also possible that this binary or one of the libraries it was linked against is corrupt, improperly built, or misconfigured. This error can also be caused by malfunctioning hardware. We will try our best to scrape up some info that will hopefully help diagnose the problem, but since we have already crashed, something is definitely wrong and this may fail. Please help us make Percona Server better by reporting any bugs at http://bugs.percona.com/ key_buffer_size=536870912 read_buffer_size=131072 max_used_connections=404 max_threads=500 thread_count=90 connection_count=90 It is possible that mysqld could use up to key_buffer_size + (read_buffer_size + sort_buffer_size)*max_threads = 1618416 K bytes of memory Hope that's ok; if not, decrease some variables in the equation. Thread pointer: 0x14edeb710 Attempting backtrace. You can use the following information to find out where mysqld died. If you see no messages after this, something went terribly wrong... stack_bottom = 7f687366ce80 thread_stack 0x30000 /usr/sbin/mysqld(my_print_stacktrace+0x2e)[0x7b52ee] /usr/sbin/mysqld(handle_fatal_signal+0x484)[0x68f024] /lib/x86_64-linux-gnu/libpthread.so.0(+0xfcb0)[0x7f9cbb23fcb0] /lib/x86_64-linux-gnu/libc.so.6(gsignal+0x35)[0x7f9cbaea6425] /lib/x86_64-linux-gnu/libc.so.6(abort+0x17b)[0x7f9cbaea9b8b] /usr/sbin/mysqld[0x858463] /usr/sbin/mysqld[0x804513] /usr/sbin/mysqld[0x808432] /usr/sbin/mysqld[0x7db8bf] /usr/sbin/mysqld(_Z13rr_sequentialP11READ_RECORD+0x1d)[0x755aed] /usr/sbin/mysqld(_Z17mysql_alter_tableP3THDPcS1_P24st_ha_create_informationP10TABLE_LISTP10Alter_infojP8st_orderb+0x216b)[0x60399b] /usr/sbin/mysqld(_Z20mysql_recreate_tableP3THDP10TABLE_LIST+0x166)[0x604bd6] /usr/sbin/mysqld[0x647da1] /usr/sbin/mysqld(_ZN24Optimize_table_statement7executeEP3THD+0xde)[0x64891e] /usr/sbin/mysqld(_Z21mysql_execute_commandP3THD+0x1168)[0x59b558] /usr/sbin/mysqld(_Z11mysql_parseP3THDPcjP12Parser_state+0x30c)[0x5a132c] /usr/sbin/mysqld(_Z16dispatch_command19enum_server_commandP3THDPcj+0x1620)[0x5a2a00] /usr/sbin/mysqld(_Z24do_handle_one_connectionP3THD+0x14f)[0x63ce6f] /usr/sbin/mysqld(handle_one_connection+0x51)[0x63cf31] /lib/x86_64-linux-gnu/libpthread.so.0(+0x7e9a)[0x7f9cbb237e9a] /lib/x86_64-linux-gnu/libc.so.6(clone+0x6d)[0x7f9cbaf63cbd] Trying to get some variables. Some pointers may be invalid and cause the dump to abort. Query (7f6300004b60): is an invalid pointer Connection ID (thread ID): 876 Status: NOT_KILLED You may download the Percona Server operations manual by visiting http://www.percona.com/software/percona-server/. You may find information in the manual which will help you identify the cause of the crash. 121115 22:31:07 [Note] Plugin 'FEDERATED' is disabled. 121115 22:31:07 InnoDB: The InnoDB memory heap is disabled 121115 22:31:07 InnoDB: Mutexes and rw_locks use GCC atomic builtins .. Then it recovered , without a reboot this time. from the log, what would cause this? I am currently running a dump to see if the problem resurfaces. edit: data partition is all in / since this is a hosted, defaulted file system unfortunately: Filesystem Size Used Avail Use% Mounted on /dev/vda3 742G 445G 260G 64% / udev 121G 4.0K 121G 1% /dev tmpfs 49G 248K 49G 1% /run none 5.0M 0 5.0M 0% /run/lock none 121G 0 121G 0% /run/shm /dev/vda1 99M 54M 40M 58% /boot my.cnf: [client] port = 3306 socket = /var/run/mysqld/mysqld.sock [mysqld_safe] socket = /var/run/mysqld/mysqld.sock nice = 0 [mysqld] skip-name-resolve innodb_file_per_table default_storage_engine=InnoDB user = mysql socket = /var/run/mysqld/mysqld.sock port = 3306 basedir = /usr datadir = /data/mysql tmpdir = /tmp skip-external-locking key_buffer = 512M max_allowed_packet = 128M thread_stack = 192K thread_cache_size = 64 myisam-recover = BACKUP max_connections = 500 table_cache = 812 table_definition_cache = 812 #query_cache_limit = 4M #query_cache_size = 512M join_buffer_size = 512K innodb_additional_mem_pool_size = 20M innodb_buffer_pool_size = 196G #innodb_file_io_threads = 4 #innodb_thread_concurrency = 12 innodb_flush_log_at_trx_commit = 1 innodb_log_buffer_size = 8M innodb_log_file_size = 1024M innodb_log_files_in_group = 2 innodb_max_dirty_pages_pct = 90 innodb_lock_wait_timeout = 120 log_error = /var/log/mysql/error.log long_query_time = 5 slow_query_log = 1 slow_query_log_file = /var/log/mysql/slowlog.log [mysqldump] quick quote-names max_allowed_packet = 16M [mysql] [isamchk] key_buffer = 16M

    Read the article

  • reiserfsck on lvm

    - by DaDaDom
    It seems like my filesystem got corrupted somehow during the last reboot of my server. I can't fsck some logical volumes anymore. The setup: root@rescue ~ # cat /mnt/rescue/etc/fstab proc /proc proc defaults 0 0 /dev/md0 /boot ext3 defaults 0 2 /dev/md1 / ext3 defaults,errors=remount-ro 0 1 /dev/systemlvm/home /home reiserfs defaults 0 0 /dev/systemlvm/usr /usr reiserfs defaults 0 0 /dev/systemlvm/var /var reiserfs defaults 0 0 /dev/systemlvm/tmp /tmp reiserfs noexec,nosuid 0 2 /dev/sda5 none swap defaults,pri=1 0 0 /dev/sdb5 none swap defaults,pri=1 0 0 [UPDATE] First question: what "part" should I check for bad blocks? The logical volume, the underlying /dev/md or the /dev/sdx below that? Is doing what I am doing the right way to go? [/UPDATE] The errormessage when checking /dev/systemlvm/usr: root@rescue ~ # reiserfsck /dev/systemlvm/usr reiserfsck 3.6.19 (2003 www.namesys.com) [...] Will read-only check consistency of the filesystem on /dev/systemlvm/usr Will put log info to 'stdout' Do you want to run this program?[N/Yes] (note need to type Yes if you do):Yes ########### reiserfsck --check started at Wed Feb 3 07:10:55 2010 ########### Replaying journal.. Reiserfs journal '/dev/systemlvm/usr' in blocks [18..8211]: 0 transactions replayed Checking internal tree.. Bad root block 0. (--rebuild-tree did not complete) Aborted Well so far, let's try --rebuild-tree: root@rescue ~ # reiserfsck --rebuild-tree /dev/systemlvm/usr reiserfsck 3.6.19 (2003 www.namesys.com) [...] Will rebuild the filesystem (/dev/systemlvm/usr) tree Will put log info to 'stdout' Do you want to run this program?[N/Yes] (note need to type Yes if you do):Yes Replaying journal.. Reiserfs journal '/dev/systemlvm/usr' in blocks [18..8211]: 0 transactions replayed ########### reiserfsck --rebuild-tree started at Wed Feb 3 07:12:27 2010 ########### Pass 0: ####### Pass 0 ####### Loading on-disk bitmap .. ok, 269716 blocks marked used Skipping 8250 blocks (super block, journal, bitmaps) 261466 blocks will be read 0%....20%....40%....60%....80%....100% left 0, 11368 /sec 52919 directory entries were hashed with "r5" hash. "r5" hash is selected Flushing..finished Read blocks (but not data blocks) 261466 Leaves among those 13086 Objectids found 53697 Pass 1 (will try to insert 13086 leaves): ####### Pass 1 ####### Looking for allocable blocks .. finished 0% left 12675, 0 /sec The problem has occurred looks like a hardware problem (perhaps memory). Send us the bug report only if the second run dies at the same place with the same block number. mark_block_used: (39508) used already Aborted Bad. But let's do it again as mentioned: [...] Flushing..finished Read blocks (but not data blocks) 261466 Leaves among those 13085 Objectids found 54305 Pass 1 (will try to insert 13085 leaves): ####### Pass 1 ####### Looking for allocable blocks .. finished 0%... left 12127, 958 /sec The problem has occurred looks like a hardware problem (perhaps memory). Send us the bug report only if the second run dies at the same place with the same block number. build_the_tree: Nothing but leaves are expected. Block 196736 - internal Aborted Same happens every time, only the actual error message changes. Sometimes I get mark_block_used: (somenumber) used already, other times the block number changes. Seems like something is REALLY broken. Are there any chances I can somehow get the partitions to work again? It's a server to which I don't have physical access directly (hosted server). Thanks in advance!

    Read the article

  • UFW as an active service on Ubuntu

    - by lamcro
    Every time I restart my computer, and check the status of the UFW firewall (sudo ufw status), it is disabled, even if I then enable and restart it. I tried putting sudo ufw enable as one of the startup applications but it asks for the sudo password every time I log on, and I'm guessing it does not protect anyone else who logs on my computer. How can I setup ufw so it is activated when I turn on my computer, and protects all accounts? Update I just tried /etc/init.d/ufw start, and it activated the firewall. Then I restarted the computer, and again it was disabled. content of /etc/ufw/ufw.conf # /etc/ufw/ufw.conf # # set to yes to start on boot ENABLED=yes # set to one of 'off', 'low', 'medium', 'high' LOGLEVEL=full content of /etc/default/ufw # /etc/default/ufw # # Set to yes to apply rules to support IPv6 (no means only IPv6 on loopback # accepted). You will need to 'disable' and then 'enable' the firewall for # the changes to take affect. IPV6=no # Set the default input policy to ACCEPT, ACCEPT_NO_TRACK, DROP, or REJECT. # ACCEPT enables connection tracking for NEW inbound packets on the INPUT # chain, whereas ACCEPT_NO_TRACK does not use connection tracking. Please note # that if you change this you will most likely want to adjust your rules. DEFAULT_INPUT_POLICY="DROP" # Set the default output policy to ACCEPT, ACCEPT_NO_TRACK, DROP, or REJECT. # ACCEPT enables connection tracking for NEW outbound packets on the OUTPUT # chain, whereas ACCEPT_NO_TRACK does not use connection tracking. Please note # that if you change this you will most likely want to adjust your rules. DEFAULT_OUTPUT_POLICY="ACCEPT" # Set the default forward policy to ACCEPT, DROP or REJECT. Please note that # if you change this you will most likely want to adjust your rules DEFAULT_FORWARD_POLICY="DROP" # Set the default application policy to ACCEPT, DROP, REJECT or SKIP. Please # note that setting this to ACCEPT may be a security risk. See 'man ufw' for # details DEFAULT_APPLICATION_POLICY="SKIP" # By default, ufw only touches its own chains. Set this to 'yes' to have ufw # manage the built-in chains too. Warning: setting this to 'yes' will break # non-ufw managed firewall rules MANAGE_BUILTINS=no # # IPT backend # # only enable if using iptables backend IPT_SYSCTL=/etc/ufw/sysctl.conf # extra connection tracking modules to load IPT_MODULES="nf_conntrack_ftp nf_nat_ftp nf_conntrack_irc nf_nat_irc" Update Followed your advise and ran update-rc.d with no luck. lester@mcgrath-pc:~$ sudo update-rc.d ufw defaults update-rc.d: warning: /etc/init.d/ufw missing LSB information update-rc.d: see <http://wiki.debian.org/LSBInitScripts> Adding system startup for /etc/init.d/ufw ... /etc/rc0.d/K20ufw -> ../init.d/ufw /etc/rc1.d/K20ufw -> ../init.d/ufw /etc/rc6.d/K20ufw -> ../init.d/ufw /etc/rc2.d/S20ufw -> ../init.d/ufw /etc/rc3.d/S20ufw -> ../init.d/ufw /etc/rc4.d/S20ufw -> ../init.d/ufw /etc/rc5.d/S20ufw -> ../init.d/ufw lester@mcgrath-pc:~$ ls -l /etc/rc?.d/*ufw lrwxrwxrwx 1 root root 13 2009-12-20 20:34 /etc/rc0.d/K20ufw -> ../init.d/ufw lrwxrwxrwx 1 root root 13 2009-12-20 20:34 /etc/rc1.d/K20ufw -> ../init.d/ufw lrwxrwxrwx 1 root root 13 2009-12-20 20:34 /etc/rc2.d/S20ufw -> ../init.d/ufw lrwxrwxrwx 1 root root 13 2009-12-20 20:34 /etc/rc3.d/S20ufw -> ../init.d/ufw lrwxrwxrwx 1 root root 13 2009-12-20 20:34 /etc/rc4.d/S20ufw -> ../init.d/ufw lrwxrwxrwx 1 root root 13 2009-12-20 20:34 /etc/rc5.d/S20ufw -> ../init.d/ufw lrwxrwxrwx 1 root root 13 2009-12-20 20:34 /etc/rc6.d/K20ufw -> ../init.d/ufw

    Read the article

  • Is it possible to repair a Cisco 3500 XL (3548) switch with POST Error messages?

    - by Alex
    I've got an old Cisco 3500 XL, and it seems to have hardware issues. I've loaded the latest IOS and cleared all config. Does anyone have any experience fixing the switch core? I'm a reasonably competent SMD solderer, can I replace/reflow some chips? I've checked the power supply voltages and it's all within tolerance, and no visible signs of any component damage. Some chips are hot to the touch. I understand that these were EOL as of 2007, but should have a lifetime warranty for the electronics. I don't have a Cisco support contract, so I can't file a ticket. What should I do? Console output: switch: dir flash: Directory of flash:/ 2 -rwx 1811584 <date> c3500xl-c3h2s-mz.120-5.WC17.bin 1799680 bytes available (1812992 bytes used) switch: boot Loading "flash:c3500xl-c3h2s-mz.120-5.WC17.bin"...################################################################################################################################################################################### File "flash:c3500xl-c3h2s-mz.120-5.WC17.bin" uncompressed and installed, entry point: 0x3000 executing... Restricted Rights Legend Use, duplication, or disclosure by the Government is subject to restrictions as set forth in subparagraph (c) of the Commercial Computer Software - Restricted Rights clause at FAR sec. 52.227-19 and subparagraph (c) (1) (ii) of the Rights in Technical Data and Computer Software clause at DFARS sec. 252.227-7013. cisco Systems, Inc. 170 West Tasman Drive San Jose, California 95134-1706 Cisco Internetwork Operating System Software IOS (tm) C3500XL Software (C3500XL-C3H2S-M), Version 12.0(5)WC17, RELEASE SOFTWARE (fc1) Copyright (c) 1986-2007 by cisco Systems, Inc. Compiled Tue 13-Feb-07 15:04 by antonino Image text-base: 0x00003000, data-base: 0x00352924 Initializing C3500XL flash... flashfs[1]: 1 files, 1 directories flashfs[1]: 0 orphaned files, 0 orphaned directories flashfs[1]: Total bytes: 3612672 flashfs[1]: Bytes used: 1812992 flashfs[1]: Bytes available: 1799680 flashfs[1]: flashfs fsck took 3 seconds. flashfs[1]: Initialization complete. ...done Initializing C3500XL flash. C3500XL POST: System Board Test: Passed C3500XL POST: Daughter Card Test: Passed C3500XL POST: CPU Buffer Test: Passed C3500XL POST: CPU Notify RAM Test: Passed C3500XL POST: CPU Interface Test: Passed C3500XL POST: Testing Switch Core: Passed Error with Switch Core BIST test Phase 0. Returns: Test Complete Low : 0x0FFFFFFF, Test Complete High : 0xFFFFFFFE Test Phase Low : 0x00000040, Test Phase High : 0x00000000 Test Phase Third : 0x00000000, Test Complete Third : 0x000001F8 C3500XL POST FAILURE: Testing Switch Core: Failed C3500XL POST FAILURE: Testing Buffer Table: Failed C3500XL POST FAILURE: Data Buffer Test: Failed C3500XL POST FAILURE: Configuring Switch Parameters: Failed C3500XL POST FAILURE: Switch Core BIST failed. C3500XL POST FAILURE: Cannot test Modules due to failure of Switch Core POST Del Mar Failure (0th Del Mar): req system failed to init C3500XL POST FAILURE: C3500XL POST FAILURE: ATM: required system failed to init C3500XL POST: Ethernet Controller Test: Passed C3500XL POST FAILURE: MII Test: Failed C3500XL POST FAILURE: Error waiting for Ethernet Controller and SW_PARAMS C3500XL POST FAILURE: Initialization/POST failed C3500XL POST FAILURE: AT: Failing because system POST failed Exception (8192)! Debug Exception (Could be NULL pointer dereference) CPU Register Context: Vector = 0x00002000 PC = 0x000F36F4 MSR = 0x00029200 CR = 0x22000024 LR = 0x000F6964 CTR = 0x001DE46C XER = 0x00000000 R0 = 0x00000000 R1 = 0x004E2580 R2 = 0x00000000 R3 = 0x00000000 R4 = 0x00000001 R5 = 0x00000000 R6 = 0x004E2718 R7 = 0x004E2718 R8 = 0x00000008 R9 = 0x00000000 R10 = 0x0000FFFF R11 = 0x00480000 R12 = 0x42000024 R13 = 0x00000000 R14 = 0x00000000 R15 = 0x00000000 R16 = 0x00000000 R17 = 0x00000000 R18 = 0x00000000 R19 = 0x00000000 R20 = 0x00000000 R21 = 0x00000000 R22 = 0x00000000 R23 = 0x00000000 R24 = 0x00000000 R25 = 0x00000020 R26 = 0x004E2718 R27 = 0x004E2718 R28 = 0x00000020 R29 = 0x00002513 R30 = 0x00000001 R31 = 0x00000000 Stack trace: PC = 0x000F36F4, SP = 0x004E2580 Frame 00: SP = 0x004E25A0 PC = 0x40000016 Frame 01: SP = 0x004E2618 PC = 0x000F6964 Frame 02: SP = 0x004E26A8 PC = 0x000F76DC Frame 03: SP = 0x004E26C8 PC = 0x000E8114 Frame 04: SP = 0x004E26F0 PC = 0x001F5BF8 Frame 05: SP = 0x004E2710 PC = 0x001F5CF4 Frame 06: SP = 0x004E2748 PC = 0x0023F4DC Frame 07: SP = 0x004E2750 PC = 0x0023E650 Frame 08: SP = 0x004E27C8 PC = 0x0023E89C Frame 09: SP = 0x004E27E0 PC = 0x0028AF34 Frame 10: SP = 0x004E27E8 PC = 0x001E38F8 Frame 11: SP = 0x004E2808 PC = 0x001E39A8 Frame 12: SP = 0x004E2820 PC = 0x0014E220 Frame 13: SP = 0x004E28C8 PC = 0x0014E39C Frame 14: SP = 0x00000000 PC = 0x001EB510

    Read the article

  • 2 drives, slow software RAID1 (md)

    - by bart613
    Hello, I've got a server from hetzner.de (EQ4) with 2* SAMSUNG HD753LJ drives (750G 32MB cache). OS is CentOS 5 (x86_64). Drives are combined together into two RAID1 partitions: /dev/md0 which is 512MB big and has only /boot partitions /dev/md1 which is over 700GB big and is one big LVM which hosts other partitions Now, I've been running some benchmarks and it seems like even though exactly the same drives, speed differs a bit on each of them. # hdparm -tT /dev/sda /dev/sda: Timing cached reads: 25612 MB in 1.99 seconds = 12860.70 MB/sec Timing buffered disk reads: 352 MB in 3.01 seconds = 116.80 MB/sec # hdparm -tT /dev/sdb /dev/sdb: Timing cached reads: 25524 MB in 1.99 seconds = 12815.99 MB/sec Timing buffered disk reads: 342 MB in 3.01 seconds = 113.64 MB/sec Also, when I run eg. pgbench which is stressing IO quite heavily, I can see following from iostat output: Device: rrqm/s wrqm/s r/s w/s rsec/s wsec/s avgrq-sz avgqu-sz await svctm %util sda 0.00 231.40 0.00 298.00 0.00 9683.20 32.49 0.17 0.58 0.34 10.24 sda1 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 sda2 0.00 231.40 0.00 298.00 0.00 9683.20 32.49 0.17 0.58 0.34 10.24 sdb 0.00 231.40 0.00 301.80 0.00 9740.80 32.28 14.19 51.17 3.10 93.68 sdb1 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 sdb2 0.00 231.40 0.00 301.80 0.00 9740.80 32.28 14.19 51.17 3.10 93.68 md1 0.00 0.00 0.00 529.60 0.00 9692.80 18.30 0.00 0.00 0.00 0.00 md0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 dm-0 0.00 0.00 0.00 0.60 0.00 4.80 8.00 0.00 0.00 0.00 0.00 dm-1 0.00 0.00 0.00 529.00 0.00 9688.00 18.31 24.51 49.91 1.81 95.92 Device: rrqm/s wrqm/s r/s w/s rsec/s wsec/s avgrq-sz avgqu-sz await svctm %util sda 0.00 152.40 0.00 330.60 0.00 5176.00 15.66 0.19 0.57 0.19 6.24 sda1 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 sda2 0.00 152.40 0.00 330.60 0.00 5176.00 15.66 0.19 0.57 0.19 6.24 sdb 0.00 152.40 0.00 326.20 0.00 5118.40 15.69 19.96 55.36 3.01 98.16 sdb1 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 sdb2 0.00 152.40 0.00 326.20 0.00 5118.40 15.69 19.96 55.36 3.01 98.16 md1 0.00 0.00 0.00 482.80 0.00 5166.40 10.70 0.00 0.00 0.00 0.00 md0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 dm-0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 dm-1 0.00 0.00 0.00 482.80 0.00 5166.40 10.70 30.19 56.92 2.05 99.04 Device: rrqm/s wrqm/s r/s w/s rsec/s wsec/s avgrq-sz avgqu-sz await svctm %util sda 0.00 181.64 0.00 324.55 0.00 5445.11 16.78 0.15 0.45 0.21 6.87 sda1 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 sda2 0.00 181.64 0.00 324.55 0.00 5445.11 16.78 0.15 0.45 0.21 6.87 sdb 0.00 181.84 0.00 328.54 0.00 5493.01 16.72 18.34 61.57 3.01 99.00 sdb1 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 sdb2 0.00 181.84 0.00 328.54 0.00 5493.01 16.72 18.34 61.57 3.01 99.00 md1 0.00 0.00 0.00 506.39 0.00 5477.05 10.82 0.00 0.00 0.00 0.00 md0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 dm-0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 dm-1 0.00 0.00 0.00 506.39 0.00 5477.05 10.82 28.77 62.15 1.96 99.00 And this is completely getting me confused. How come two exactly the same specced drives have such a difference in write speed (see util%)? I haven't really paid attention to those speeds before, so perhaps that something normal -- if someone could confirm I would be really grateful. Otherwise, if someone have seen such behavior again or knows what is causing such behavior I would really appreciate answer. I'll also add that both "smartctl -a" and "hdparm -I" output are exactly the same and are not indicating any hardware problems. The slower drive was changed already two times (to new ones). Also I asked to change the drives with places, and then sda were slower and sdb quicker (so the slow one was the same drive). SATA cables were changed two times already.

    Read the article

  • How to restore Linode to Vagrant VM?

    - by Iain Elder
    I'm trying to set up a Linux development environment so I can safely make changes to my website without breaking the live site. Linode hosts my live site. A simple solution would be to host my development server on Linode as well, but I want to avoid doubling my hosting costs. The cheapest way I see is to use Vagrant on my Windows workstation to host my development environment. After I attempt to restore the backup to Vagrant and reboot the VM, I can no longer ssh into the Vagrant host. It's probably because by restoring the backup I overwrite some special Vagrant configuration, but I'm not sure how to avoid that. How do I make this approach work? If my approach is fundamentally wrong, can you suggest an alternative? Creating the backup On the Linode I used these commands to create a compressed copy of the entire filesystem, while ignoring things that shouldn't be included in the backup: $ sudo rsync -ahvz --exclude={/dev/*,/proc/*,/sys/*,/tmp/*,/run/*,/mnt/*,/backup/*} /* /backup/2 $ sudo tar -czf /backup/2.gz /backup/2 The backup file is called 2.gz because this is thesecond backup. The first backup is called 1.gz. I use WinSCP to copy the backup file to my Windows workstation. Setting up the Vagrant host I need a Vagrant box that matches my Linode operating system (Ubuntu 12.04.3 LTS, kernel 3.9.3). I selected the closet match from vagrantbox.es: Ubuntu Server Precise 12.04.3 amd64 Kernel is ready for Docker (Docker not included) On my workstation I ran these commands to add the box and initialize and boot an instance: $ vagrant box add ubuntu-precise http://nitron-vagrant.s3-website-us-east-1.amazonaws.com/vagrant_ubuntu_12.04.3_amd64_virtualbox.box $ mkdir linode-test $ cd linode-test $ vagrant init ubuntu-precise $ vagrant up Now Vagrant is running a machine with SSH on port 2222. The operating system version is the same. The kernel version is 3.8.0. Sounds close enough. Restoring the backup With WinSCP I copied the backup file 2.gz to /home/vagrant/2.gz on the Vagrant box. With PuTTY I connected via ssh to my new Vagrant box: On the box move the backup to the filesystem root. $ sudo mv 2.gz / Extract the archive to the filesystem root: $ sudo tar -xvpz -f 2.gz -C / --strip-components=2 (I discovered I need to use strip components because all files in the archive have the prefix backup/2/. I'll fix this for the next backup.) After the tar command completes, I log out of the box. Testing the backup When I try to log in again, it doesn't let me log in as vagrant with a password any more. It does let me log in as iain, my user on the live Linode, with a password. That surprised me because I disabled password authentication on my live Linode. I figured that I have to restart the ssh service for the change to take effect. Instead of restarting just ssh, I chose to restart the whole system. Now I can't even get to the login screen. PuTTY says "connection refused" when I try to connect. What went wrong?

    Read the article

  • Dual head setup for Ubuntu 10.04.1 and Windows XP Pro with same hardware configuration

    - by mejpark
    I have a Dell OptiPlex 360 workstation at work, with 2 x ATI RV280 [Radeon 9200 PRO] graphics cards installed, which are attached to two identical 19" HII flat panel monitors. I'm using the open source Radeon driver with Ubuntu, and the proprietary drivers with Windows. The good news is that dual head configuration works for both OSes. The bad news is, I have to use a different hardware configuration for each OS to achieve this. Hardware config #1: Dual monitors work for Windows XP Pro like this: First display -> external VGA port Second display -> DVI input on gfx card Hardware config #2: Dual monitors work for Ubuntu 10.04.1 like this: First display -> VGA port on gfx card Second display -> DVI input on gfx card I connected up the displays according to Config #2 and booted up Windows, which resulted in a mirror image on both screens. I was unable to login, as the login box was not visible. I unplugged the VGA lead from gfx card and plugged it into the external VGA port (Config #1) - Windows dual head works again, but the VGA-connected screen is not recognised by Ubuntu and remains in standby mode. Is it possible to configure a dual head setup for Ubuntu using Config #1, or am I missing something? I tried setting up dual monitors using Config #1, this morning which didn't work. By default, there is no xorg.conf file in Ubuntu 10.04.1, so I generated one using: $ sudo X :2 -configure X.Org X Server 1.7.6 Release Date: 2010-03-17 X Protocol Version 11, Revision 0 Build Operating System: Linux 2.6.24-27-server i686 Ubuntu Current Operating System: Linux harrier 2.6.32-24-generic #42-Ubuntu SMP Fri Aug 20 14:24:04 UTC 2010 i686 Kernel command line: BOOT_IMAGE=/boot/vmlinuz-2.6.32-24-generic root=UUID=a34c1931-98d4-4a34-880c-c227a2936c4a ro quiet splash Build Date: 21 July 2010 12:47:34PM xorg-server 2:1.7.6-2ubuntu7.3 (For technical support please see http://www.ubuntu.com/support) Current version of pixman: 0.16.4 Before reporting problems, check http://wiki.x.org to make sure that you have the latest version. Markers: (--) probed, (**) from config file, (==) default setting, (++) from command line, (!!) notice, (II) informational, (WW) warning, (EE) error, (NI) not implemented, (??) unknown. (==) Log file: "/var/log/Xorg.2.log", Time: Mon Sep 13 10:02:02 2010 List of video drivers: apm ark intel mach64 s3virge trident mga tseng ati nouveau neomagic i740 openchrome voodoo s3 i128 radeon siliconmotion nv ztv vmware v4l chips rendition savage sisusb tdfx geode sis r128 cirrus fbdev vesa (++) Using config file: "/home/michael/xorg.conf.new" (==) Using config directory: "/usr/lib/X11/xorg.conf.d" (II) [KMS] No DRICreatePCIBusID symbol, no kernel modesetting. Xorg detected your mouse at device /dev/input/mice. Please check your config if the mouse is still not operational, as by default Xorg tries to autodetect the protocol. Xorg has configured a multihead system, please check your config. Your xorg.conf file is /home/michael/xorg.conf.new To test the server, run 'X -config /home/michael/xorg.conf.new' ddxSigGiveUp: Closing log $ sudo X -config /home/michael/xorg.conf.new Fatal server error: Server is already active for display 0 If this server is no longer running, remove /tmp/.X0-lock and start again. Please consult the The X.Org Foundation support at http://wiki.x.org for help. ddxSigGiveUp: Closing log I then booted Ubuntu in failsafe mode, dropped into root shell, and executed $ X -config /home/michael/xorg.conf.new again. The screen went blank and turned off, so

    Read the article

  • Performance issues when using SSD for a developer notebook (WAMP/LAMP stack)?

    - by András Szepesházi
    I'm a web application developer using my notebook as a standalone development environment (WAMP stack). I just switched from a Core2-duo Vista 32 bit notebook with 2Gb RAM and SATA HDD, to an i5-2520M Win7 64 bit with 4Gb RAM and 128 GB SDD (Corsair P3 128). My initial experience was what I expected, fast boot, quick load of all the applications (Eclipse takes now 5 seconds as opposed to 30s on my old notebook), overall great experience. Then I started to build up my development stack, both as LAMP (using VirtualBox with a debian guest) and WAMP (windows native apache + mysql + php). I wanted to compare those two. This still all worked great out, then I started to pull in my projects to these stacks. And here came the nasty surprise, one of those projects produced a lot worse response times than on my old notebook (that was true for both the VirtualBox and WAMP stack). Apache, php and mysql configurations were practically identical in all environments. I started to do a lot of benchmarking and profiling, and here is what I've found: All general benchmarks (Performance Test 7.0, HDTune Pro, wPrime2 and some more) gave a big advantage to the new notebook. Nothing surprising here. Disc specific tests showed that read/write operations peaked around 380M/160M for the SSD, and all the different sized block operations also performed very well. Started apache performance benchmarking with Apache Benchmark for a small static html file (10 concurrent threads, 500 iterations). Old notebook: min 47ms, median 111ms, max 156ms New WAMP stack: min 71ms, median 135ms, max 296ms New LAMP stack (in VirtualBox): min 6ms, median 46ms, max 175ms Right here I don't get why the native WAMP stack performed so bad, but at least the LAMP environment brought the expected speed. Apache performance measurement for non-cached php content. The php runs a loop of 1000 and generates sha1(uniqid()) inisde. Again, 10 concurrent threads, 500 iterations were used for the benchmark. Old notebook: min 0ms, median 39ms, max 218ms New WAMP stack: min 20ms, median 61ms, max 186ms New LAMP stack (in VirtualBox): min 124ms, median 704ms, max 2463ms What the hell? The new LAMP performed miserably, and even the new native WAMP was outperformed by the old notebook. php + mysql test. The test consists of connecting to a database and reading a single record form a table using INNER JOIN on 3 more (indexed) tables, repeated 100 times within a loop. Databases were identical. 10 concurrent threads, 100 iterations were used for the benchmark. Old notebook: min 1201ms, median 1734ms, max 3728ms New WAMP stack: min 367ms, median 675ms, max 1893ms New LAMP stack (in VirtualBox): min 1410ms, median 3659ms, max 5045ms And the same test with concurrency set to 1 (instead of 10): Old notebook: min 1201ms, median 1261ms, max 1357ms New WAMP stack: min 399ms, median 483ms, max 539ms New LAMP stack (in VirtualBox): min 285ms, median 348ms, max 444ms Strictly for my purposes, as I'm using a self contained development environment (= low concurrency) I could be satisfied with the second test's result. Though I have no idea why the VirtualBox environment performed so bad with higher concurrency. Finally I performed a test of including many php files. The application that I mentioned at the beginning, the one that was performing so bad, has a heavy bootstrap, loads hundreds of small library and configuration files while initializing. So this test does nothing else just includes about 100 files. Concurrency set to 1, 100 iterations: Old notebook: min 140ms, median 168ms, max 406ms New WAMP stack: min 434ms, median 488ms, max 604ms New LAMP stack (in VirtualBox): min 413ms, median 1040ms, max 1921ms Even if I consider that VirtualBox reached those files via shared folders, and that slows things down a bit, I still don't see how could the old notebook outperform so heavily both new configurations. And I think this is the real root of the slow performance, as the application uses even more includes, and the whole bootstrap will occur several times within a page request (for each ajax call, for example). To sum it up, here I am with a brand new high-performance notebook that loads the same page in 20 seconds, that my old notebook can do in 5-7 seconds. Needless to say, I'm not a very happy person right now. Why do you think I experience these poor performance values? What are my options to remedy this situation?

    Read the article

  • Can't sync filesystem without reboot

    - by Fabio
    I'm having an issue with a linux server. Once a week the running mysql instance hangs and there is no way to fully stop it. If I kill it, it remains in zombie status and init does not reap its pid. The server is used for staging deployments and some internal tools, so it's not under heavy load. The only process constantly used id mysql and for this I think that it's the only process which suffer of this issue. I've searched system logs for errors and the only thing I found is this error (repeated a couple of times) in dmesg output: [706560.640085] INFO: task mysqld:31965 blocked for more than 120 seconds. [706560.640198] "echo 0 > /proc/sys/kernel/hung_task_timeout_secs" disables this message. [706560.640312] mysqld D ffff88032fd93f40 0 31965 1 0x00000000 [706560.640317] ffff880242a27d18 0000000000000086 ffff88031a50dd00 ffff880242a27fd8 [706560.640321] ffff880242a27fd8 ffff880242a27fd8 ffff88031e549740 ffff88031a50dd00 [706560.640325] ffff88031a50dd00 ffff88032fd947f8 0000000000000002 ffffffff8112f250 [706560.640328] Call Trace: [706560.640338] [<ffffffff8112f250>] ? __lock_page+0x70/0x70 [706560.640344] [<ffffffff816cb1b9>] schedule+0x29/0x70 [706560.640347] [<ffffffff816cb28f>] io_schedule+0x8f/0xd0 [706560.640350] [<ffffffff8112f25e>] sleep_on_page+0xe/0x20 [706560.640353] [<ffffffff816c9900>] __wait_on_bit+0x60/0x90 [706560.640356] [<ffffffff8112f390>] wait_on_page_bit+0x80/0x90 [706560.640360] [<ffffffff8107dce0>] ? autoremove_wake_function+0x40/0x40 [706560.640363] [<ffffffff8112f891>] filemap_fdatawait_range+0x101/0x190 [706560.640366] [<ffffffff81130975>] filemap_write_and_wait_range+0x65/0x70 [706560.640371] [<ffffffff8122e441>] ext4_sync_file+0x71/0x320 [706560.640376] [<ffffffff811c3e6d>] do_fsync+0x5d/0x90 [706560.640379] [<ffffffff811c40d0>] sys_fsync+0x10/0x20 [706560.640383] [<ffffffff816d495d>] system_call_fastpath+0x1a/0x1f When this happens the only way to make everything working again is a full reboot, but in order to do that I'm forced to use this command after I've manually stopped all running processes echo b > /proc/sysrq-trigger otherwise normal reboot process hangs forever. I've tracked reboots script and I've found out that also the reboot process hangs on a sync call, this one in /etc/init.d/sendsigs (I'm on ubuntu) # Flush the kernel I/O buffer before we start to kill # processes, to make sure the IO of already stopped services to # not slow down the remaining processes to a point where they # are accidentily killed with SIGKILL because they did not # manage to shut down in time. sync I'm almost sure that the cause of this is an hardware issue (the RAID controller???) also because I've other two machines with the same hardware and software configuration and they don't suffer of this, but I can't find any hint in syslog or dmesg. I've also installed smartmontools and mcelog packages but none of them did report any issue. What can I do to track the cause of this issue? Today is happened again, here is the status of system after triggering a reboot init---console-kit-dae---64*[{console-kit-dae}] +-dbus-daemon +-mcelog +-mysqld---{mysqld} +-newrelic-daemon---newrelic-daemon---11*[{newrelic-daemon}] +-ntpd +-polkitd---{polkitd} +-python3 +-rpc.idmapd +-rpc.statd +-rpcbind +-sh---rc---S20sendsigs---sync +-smartd +-snmpd +-sshd---sshd---zsh---sudo---zsh---pstree +-sshd---sshd---zsh---sudo---zsh And here is the status of sync process # ps aux | grep sync root 3637 0.1 0.0 4352 372 ? D 05:53 0:00 sync i.e. Uninterruptible sleep... Hardware specs as reported by lshw I think the raid controller is a fake raid. I usually don't deal with hardware (and for the record I don't have physical access to it) description: Computer product: X7DBP () vendor: Supermicro version: 0123456789 serial: 0123456789 width: 64 bits capabilities: smbios-2.4 dmi-2.4 vsyscall32 configuration: administrator_password=disabled boot=normal frontpanel_password=unknown keyboard_password=unknown power-on_password=disabled uuid=53D19F64-D663-A017-8922-0030487C1FEE *-core description: Motherboard product: X7DBP vendor: Supermicro physical id: 0 version: PCB Version serial: 0123456789 *-firmware description: BIOS vendor: Phoenix Technologies LTD physical id: 0 version: 6.00 date: 05/29/2007 size: 106KiB capacity: 960KiB capabilities: pci pnp upgrade shadowing escd cdboot bootselect edd int13floppy2880 acpi usb ls120boot zipboot biosbootspecification *-storage description: RAID bus controller product: 631xESB/632xESB SATA RAID Controller vendor: Intel Corporation physical id: 1f.2 bus info: pci@0000:00:1f.2 version: 09 width: 32 bits clock: 66MHz capabilities: storage pm bus_master cap_list configuration: driver=ahci latency=0 resources: irq:19 ioport:18a0(size=8) ioport:1874(size=4) ioport:1878(size=8) ioport:1870(size=4) ioport:1880(size=32) memory:d8500400-d85007ff

    Read the article