Search Results

Search found 1864 results on 75 pages for 'raid 0'.

Page 35/75 | < Previous Page | 31 32 33 34 35 36 37 38 39 40 41 42  | Next Page >

  • Server RAID 5 failed...all I have left is my compiled website

    - by David Murdoch
    Yesterday, 2 of the 3 drives in my dev server's RAID 5 decided to die on me (with no warning). I've come to grips with the fact that my data is most likely lost unless I shell out some major bucks for professional data-resortoration. People, don't be an idiot like me and treat your RAID as a data backup! Luckily I published the site about 4 hours before my files went bye-bye. Is there any way to run some [magical] program to restore my compiled site to their original files? Also: I develop on one machine with the files stored on the server...is there some visual studio 2010 web cache on my local machine (the one that didn't crash) that I may be able to use?

    Read the article

  • megacli forceWB

    - by Pascal den Bekker
    We are using a raid controller: LSI Logic / Symbios Logic MegaRAID SAS 2008 But there is no BBU on Board, is there a way to force the WB Cache ?? I tried following: - /opt/MegaRAID/MegaCli/MegaCli64 -LDSetProp CachedBadBBU -L0 -a0 Failed to set Write Cache OK if bad BBU on Adapter 0, VD 0. FW error description: The requested command has invalid arguments. Can anyone help? Cheers, Pascal

    Read the article

  • Is Splitting IDE hdds between Primary and Secondary faster?

    - by earlz
    Hello, I'm doing RAID 0 on two IDE harddrives (yes, this is old hardware). Will the harddrives be faster if I attach them separately so that one is on the Primary IDE controller and the other is on the Secondary IDE controller? Or would it just be as good as having them both on the Primary IDE as master and slave?

    Read the article

  • Adaptec 5805 after reboot don't starting

    - by Rakedko ShotGuns
    After rebooting the system, the controller is not included. It only works if the computer is shut down and turn off. Late i update firmware "Adaptec RAID 5805 Firmware Build 18948" How to fix the problem? add Log Configuration summary Server name.....................raid_test Adaptec Storage Manager agent...7.31.00 (18856) Adaptec Storage Manager console.7.31.00 (18856) Number of controllers...........1 Operating system................Windows Configuration information for controller 1 ------------------------------------------------------- Type............................Controller Model...........................Adaptec 5805 Controller number...............1 Physical slot...................2 Installed memory size...........512 MB Serial number...................8C4510C6C9E Boot ROM........................5.2-0 (18948) Firmware........................5.2-0 (18948) Device driver...................5.2-0 (16119) Controller status...............Optimal Battery status..................Charging Battery temperature.............Normal Battery charge amount (%).......37 Estimated charge remaining......0 days, 16 hours, 12 minutes Background consistency check....Disabled Copy back.......................Disabled Controller temperature..........Normal (40C / 104F) Default logical drive task priorityHigh Performance mode................Dynamic Number of logical devices.......1 Number of hot-spare drives......0 Number of ready drives..........0 Number of drive(s) assigned to MaxCache cache0 Maximum drives allowed for MaxCache cache8 MaxCache Read Cache Pool Size...0 GB NCQ status......................Enabled Stay awake status...............Disabled Internal drive spinup limit.....0 External drive spinup limit.....0 Phy 0...........................No device attached Phy 1...........................No device attached Phy 2...........................No device attached Phy 3...........................1.50 Gb/s Phy 4...........................No device attached Phy 5...........................No device attached Phy 6...........................No device attached Phy 7...........................No device attached Statistics version..............2.0 SSD Cache size..................0 Pages on fetch list.............0 Fetch list candidates...........0 Candidate replacements..........0 69319...........................31293 Logical device..................0 Logical device name............. RAID level......................Simple volume Data space......................148,916 GB Date created....................09/19/2012 Interface type..................Serial ATA State...........................Optimal Read-cache mode.................Enabled Preferred MaxCache read cache settingEnabled Actual MaxCache read cache setting Disabled Write-cache mode................Enabled (write-back) Write-cache setting.............Enabled (write-back) Partitioned.....................Yes Protected by hot spare..........No Bootable........................Yes Bad stripes.....................No Power Status....................Disabled Power State.....................Active Reduce RPM timer................Never Power off timer.................Never Verify timer....................Never Segment 0.......................Present: controller 1, connector 0, device 0, S/N 9RX3KZMT Overall host IOs................99075 Overall MB......................4411203 DRAM cache hits.................71929 SSD cache hits..................0 Uncached IOs....................29239 Overall disk failures...........0 DRAM cache full hits............71929 DRAM cache fetch / flush wait...0 DRAM cache hybrid reads.........3476 DRAM cache flushes..............-- Read hits.......................0 Write hits......................0 Valid Pages.....................0 Updates on writes...............0 Invalidations by large writes...0 Invalidations by R/W balance....0 Invalidations by replacement....0 Invalidations by other..........0 Page Fetches....................0 0...............................0 73..............................10822 8...............................3 46138...........................4916 27184...........................15226 20875...........................323 16982...........................1771 1563............................5317 1948............................2969 Serial attached SCSI ----------------------- Type............................Disk drive Vendor..........................Unknown Model...........................ST3160815AS Serial Number...................9RX3KZMT Firmware level..................3.AAD Reported channel................0 Reported SCSI device ID.........0 Interface type..................Serial ATA Size............................149,05 GB Negotiated transfer speed.......1.50 Gb/s State...........................Optimal S.M.A.R.T. error................No Write-cache mode................Write back Hardware errors.................0 Medium errors...................0 Parity errors...................0 Link failures...................0 Aborted commands................0 S.M.A.R.T. warnings.............0 Solid-state disk (non-spinning).false MaxCache cache capable..........false MaxCache cache assigned.........false NCQ status......................Enabled Phy 0...........................1.50 Gb/s Power State.....................Full rpm Supported power states..........Full rpm, Powered off 0x01............................113 0x03............................98 0x04............................99 0x05............................100 0x07............................83 0x09............................75 0x0A............................100 0x0C............................99 0xBB............................100 0xBD............................100 0xBE............................61 0xC2............................39 0xC3............................69 0xC5............................100 0xC6............................100 0xC7............................200 0xC8............................100 0xCA............................100 Aborted commands................0 Link failures...................0 Medium errors...................0 Parity errors...................0 Hardware errors.................0 SMART errors....................0 End of the configuration information for controller 1 List item

    Read the article

  • How to address a recurring low temperature error seen at every boot-up?

    - by GregC
    After updating to latest controller firmware, I started receiving the following error messages: LSI 2208 ROC: Temperature sensor below error threshold on enclosure 1 Sensors 5 thru 7 Is this something I should worry about, or is it a Red Herring? Details: I have a Sans Digital NexentaSTOR 24-disk JBOD enclosure connected to LSI 9286-8e RAID-on-Chip controller with two SAS cables. Seagate ES.2 3TB SAS hard drives populate every bay in the enclosure.

    Read the article

  • formatting before md device creation in RAID5

    - by kumar
    consider you are creating a raid5 device with three drives. mdadm --create /dev/md0 --leve=5 --raid-disk=3 /dev/sda1 /dev/sdb1 /dev/sdc1 After issuing this command , I can see the progress of md device creating using cat /proc/mdstat. During the progress ITSELF, can I create a file ssytem partition say ext2 on md0 device like: mkfs.ext2 /dev/md0. Actually I am able to create this and want to confirm whether doing this before 100% completion of md device creation is CORRECT?

    Read the article

  • Raid0 setup - What should 'my computer' say?

    - by superexsl
    Hey, I'm not a hardware person, so maybe someone here could help me. I ordered a PC from Dell that has "Serial ATA Raid 0 "Stripe"(7200RPM)Dual HDD" (2x500gb). However, I've just noticed that there's only one HD of 1TB (which is the default option when ordering). Should I be seeing two HDDs in "My Computer" or does the Raid0 setup simply improve performance rather than have (and display) two individual HDDs? How can I check if my computer does have a 'raid0' setup? Thanks

    Read the article

  • EBS with RAID0 (striping) and restoring snapshots

    - by grourk
    We have a MySQL database on EC2 and are looking at the disk IO performance there. Currently we have a single EBS volume with XFS and take snapshots for backup. It seems that a lot of people have seen significant performance gains by striping across multiple EBS volumes with software RAID. If this is done, how does one take snapshots and ensure the consistency of the file system? It seems to me that restoring the file system from multiple snapshots could be tricky.

    Read the article

  • Adaptec 5805 not recognized after reboot

    - by Rakedko ShotGuns
    After rebooting the system, the controller is not recognized. It only works if the computer is shut down and turned off. I have recently updated the firmware to "Adaptec RAID 5805 Firmware Build 18948". How do I fix the problem? Configuration summary --------------------------- 1. Server name.....................raid_test Adaptec Storage Manager agent...7.31.00 (18856) Adaptec Storage Manager console.7.31.00 (18856) Number of controllers...........1 Operating system................Windows Configuration information for controller 1 ------------------------------------------------------- Type............................Controller Model...........................Adaptec 5805 Controller number...............1 Physical slot...................2 Installed memory size...........512 MB Serial number...................8C4510C6C9E Boot ROM........................5.2-0 (18948) Firmware........................5.2-0 (18948) Device driver...................5.2-0 (16119) Controller status...............Optimal Battery status..................Charging Battery temperature.............Normal Battery charge amount (%).......37 Estimated charge remaining......0 days, 16 hours, 12 minutes Background consistency check....Disabled Copy back.......................Disabled Controller temperature..........Normal (40C / 104F) Default logical drive task priority High Performance mode................Dynamic Number of logical devices.......1 Number of hot-spare drives......0 Number of ready drives..........0 Number of drive(s) assigned to MaxCache cache0 Maximum drives allowed for MaxCache cache8 MaxCache Read Cache Pool Size...0 GB NCQ status......................Enabled Stay awake status...............Disabled Internal drive spinup limit.....0 External drive spinup limit.....0 Phy 0...........................No device attached Phy 1...........................No device attached Phy 2...........................No device attached Phy 3...........................1.50 Gb/s Phy 4...........................No device attached Phy 5...........................No device attached Phy 6...........................No device attached Phy 7...........................No device attached Statistics version..............2.0 SSD Cache size..................0 Pages on fetch list.............0 Fetch list candidates...........0 Candidate replacements..........0 69319...........................31293 Logical device..................0 Logical device name............. RAID level......................Simple volume Data space......................148,916 GB Date created....................09/19/2012 Interface type..................Serial ATA State...........................Optimal Read-cache mode.................Enabled Preferred MaxCache read cache settingEnabled Actual MaxCache read cache setting Disabled Write-cache mode................Enabled (write-back) Write-cache setting.............Enabled (write-back) Partitioned.....................Yes Protected by hot spare..........No Bootable........................Yes Bad stripes.....................No Power Status....................Disabled Power State.....................Active Reduce RPM timer................Never Power off timer.................Never Verify timer....................Never Segment 0.......................Present: controller 1, connector 0, device 0, S/N 9RX3KZMT Overall host IOs................99075 Overall MB......................4411203 DRAM cache hits.................71929 SSD cache hits..................0 Uncached IOs....................29239 Overall disk failures...........0 DRAM cache full hits............71929 DRAM cache fetch / flush wait...0 DRAM cache hybrid reads.........3476 DRAM cache flushes..............-- Read hits.......................0 Write hits......................0 Valid Pages.....................0 Updates on writes...............0 Invalidations by large writes...0 Invalidations by R/W balance....0 Invalidations by replacement....0 Invalidations by other..........0 Page Fetches....................0 0...............................0 73..............................10822 8...............................3 46138...........................4916 27184...........................15226 20875...........................323 16982...........................1771 1563............................5317 1948............................2969 Serial attached SCSI ----------------------- Type............................Disk drive Vendor..........................Unknown Model...........................ST3160815AS Serial Number...................9RX3KZMT Firmware level..................3.AAD Reported channel................0 Reported SCSI device ID.........0 Interface type..................Serial ATA Size............................149,05 GB Negotiated transfer speed.......1.50 Gb/s State...........................Optimal S.M.A.R.T. error................No Write-cache mode................Write back Hardware errors.................0 Medium errors...................0 Parity errors...................0 Link failures...................0 Aborted commands................0 S.M.A.R.T. warnings.............0 Solid-state disk (non-spinning).false MaxCache cache capable..........false MaxCache cache assigned.........false NCQ status......................Enabled Phy 0...........................1.50 Gb/s Power State.....................Full rpm Supported power states..........Full rpm, Powered off 0x01............................113 0x03............................98 0x04............................99 0x05............................100 0x07............................83 0x09............................75 0x0A............................100 0x0C............................99 0xBB............................100 0xBD............................100 0xBE............................61 0xC2............................39 0xC3............................69 0xC5............................100 0xC6............................100 0xC7............................200 0xC8............................100 0xCA............................100 Aborted commands................0 Link failures...................0 Medium errors...................0 Parity errors...................0 Hardware errors.................0 SMART errors....................0 End of the configuration information for controller 1

    Read the article

  • How to recover data from a partially overwritten partition

    - by shredder12
    By mistake, I configured a 900GB partition to be part of a 50GB raid. The sync is complete and my understanding is that only the first 50GB of the bigger partition is overwritten. How do I recover the rest of the data? When I try to mount this partition by identifying it as ext3, it mounts only the 50GB overwritten space. This partition was earlier divided into various logical volumes(all ext3 filesystems) through LVM. Any suggestions?

    Read the article

  • Finding out why Dell Controler is Degraded

    - by Kyle Brandt
    I installed open manage on a couple of my PE 2950s for snmp monitoring of the RAID. All the checks seem to come back okay except for controllerState: [root@aMachine ~]# snmpwalk -v 2c -c bestNotToPostPasswords myMachine -m +StorageManagement-MIB controllerstate StorageManagement-MIB::controllerState.1 = INTEGER: degraded(6) Other checks seems to indicate the battery, LD, and physicals disks are all good unless I missing something. Can anyone tell if I am missing something or neglecting something import in my RAID monitoring/understanding? I get degraded for both these servers I have set up. A walk of the entire storage management tree for on of them: StorageManagement-MIB::softwareVersion.0 = STRING: "3.2.0" StorageManagement-MIB::globalStatus.0 = INTEGER: warning(2) StorageManagement-MIB::softwareManufacturer.0 = STRING: "Dell Inc." StorageManagement-MIB::softwareProduct.0 = STRING: "Server Administrator (Storage Management)" StorageManagement-MIB::softwareDescription.0 = STRING: "Configuration and monitoring of disk storage devices." StorageManagement-MIB::displayName.0 = STRING: "Server Administrator (Storage Management)" StorageManagement-MIB::description.0 = STRING: "Configuration and monitoring of disk storage devices." StorageManagement-MIB::agentVendor.0 = STRING: "Dell Inc." StorageManagement-MIB::agentTimeStamp.0 = INTEGER: 1273842310 StorageManagement-MIB::agentGetTimeout.0 = INTEGER: 5 StorageManagement-MIB::agentModifiers.0 = INTEGER: 0 StorageManagement-MIB::agentRefreshRate.0 = INTEGER: 300 StorageManagement-MIB::agentMibVersion.0 = STRING: "3.2" StorageManagement-MIB::agentManagementSoftwareURLName.0 = "" StorageManagement-MIB::agentGlobalSystemStatus.0 = INTEGER: nonCritical(4) StorageManagement-MIB::agentLastGlobalSystemStatus.0 = INTEGER: ok(3) StorageManagement-MIB::agentSmartThermalShutdown.0 = INTEGER: notApplicable(3) StorageManagement-MIB::controllerNumber.1 = INTEGER: 1 StorageManagement-MIB::controllerName.1 = STRING: "PERC 5/i Integrated" StorageManagement-MIB::controllerVendor.1 = STRING: "DELL" StorageManagement-MIB::controllerType.1 = INTEGER: sas(6) StorageManagement-MIB::controllerState.1 = INTEGER: degraded(6) StorageManagement-MIB::controllerRebuildRateInPercent.1 = INTEGER: 30 StorageManagement-MIB::controllerFWVersion.1 = STRING: "5.0.2-0003" StorageManagement-MIB::controllerCacheSizeInMB.1 = INTEGER: 256 StorageManagement-MIB::controllerCacheSizeInBytes.1 = INTEGER: 0 StorageManagement-MIB::controllerPhysicalDeviceCount.1 = INTEGER: 5 StorageManagement-MIB::controllerLogicalDeviceCount.1 = INTEGER: 1 StorageManagement-MIB::controllerRollUpStatus.1 = INTEGER: nonCritical(4) StorageManagement-MIB::controllerComponentStatus.1 = INTEGER: nonCritical(4) StorageManagement-MIB::controllerNexusID.1 = STRING: "\\0" StorageManagement-MIB::controllerAlarmState.1 = INTEGER: disabled(2) StorageManagement-MIB::controllerDriverVersion.1 = STRING: "00.00.03.05 " StorageManagement-MIB::controllerPCISlot.1 = STRING: "embedded" StorageManagement-MIB::controllerClusterMode.1 = INTEGER: notApplicable(99) StorageManagement-MIB::controllerMinFWVersion.1 = STRING: "5.2.1-0067" StorageManagement-MIB::controllerMinDriverVersion.1 = STRING: "00.00.03.21" StorageManagement-MIB::controllerChannelCount.1 = INTEGER: 2 StorageManagement-MIB::controllerReconstructRate.1 = INTEGER: 30 StorageManagement-MIB::controllerPatrolReadRate.1 = INTEGER: 30 StorageManagement-MIB::controllerBGIRate.1 = INTEGER: 30 StorageManagement-MIB::controllerCheckConsistencyRate.1 = INTEGER: 30 StorageManagement-MIB::controllerPatrolReadMode.1 = INTEGER: automatic(1) StorageManagement-MIB::controllerPatrolReadState.1 = INTEGER: stopped(1) StorageManagement-MIB::controllerPatrolReadIterations.1 = INTEGER: 162 StorageManagement-MIB::controllerEntry.57.1 = INTEGER: 99 StorageManagement-MIB::controllerEntry.58.1 = INTEGER: 99 StorageManagement-MIB::channelNumber.1 = INTEGER: 1 StorageManagement-MIB::channelNumber.2 = INTEGER: 2 StorageManagement-MIB::channelName.1 = STRING: "Connector 0" StorageManagement-MIB::channelName.2 = STRING: "Connector 1" StorageManagement-MIB::channelState.1 = INTEGER: ready(1) StorageManagement-MIB::channelState.2 = INTEGER: ready(1) StorageManagement-MIB::channelRollUpStatus.1 = INTEGER: ok(3) StorageManagement-MIB::channelRollUpStatus.2 = INTEGER: ok(3) StorageManagement-MIB::channelComponentStatus.1 = INTEGER: ok(3) StorageManagement-MIB::channelComponentStatus.2 = INTEGER: ok(3) StorageManagement-MIB::channelNexusID.1 = STRING: "\\0\\0" StorageManagement-MIB::channelNexusID.2 = STRING: "\\0\\1" StorageManagement-MIB::channelBusType.1 = INTEGER: sas(8) StorageManagement-MIB::channelBusType.2 = INTEGER: sas(8) StorageManagement-MIB::enclosureNumber.1 = INTEGER: 1 StorageManagement-MIB::enclosureName.1 = STRING: "Backplane" StorageManagement-MIB::enclosureVendor.1 = STRING: "DELL" StorageManagement-MIB::enclosureState.1 = INTEGER: ready(1) StorageManagement-MIB::enclosureProductID.1 = STRING: "BACKPLANE " StorageManagement-MIB::enclosureType.1 = INTEGER: internal(1) StorageManagement-MIB::enclosureChannelNumber.1 = INTEGER: 0 StorageManagement-MIB::enclosureRollUpStatus.1 = INTEGER: ok(3) StorageManagement-MIB::enclosureComponentStatus.1 = INTEGER: ok(3) StorageManagement-MIB::enclosureNexusID.1 = STRING: "\\0\\0\\0" StorageManagement-MIB::enclosureFirmwareVersion.1 = STRING: "1.00" StorageManagement-MIB::enclosureSASAddress.1 = STRING: "50019090B4C67200" StorageManagement-MIB::arrayDiskNumber.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskNumber.2 = INTEGER: 2 StorageManagement-MIB::arrayDiskNumber.3 = INTEGER: 3 StorageManagement-MIB::arrayDiskNumber.4 = INTEGER: 4 StorageManagement-MIB::arrayDiskName.1 = STRING: "Physical Disk 0:0:0" StorageManagement-MIB::arrayDiskName.2 = STRING: "Physical Disk 0:0:1" StorageManagement-MIB::arrayDiskName.3 = STRING: "Physical Disk 0:0:2" StorageManagement-MIB::arrayDiskName.4 = STRING: "Physical Disk 0:0:3" StorageManagement-MIB::arrayDiskVendor.1 = STRING: "DELL " StorageManagement-MIB::arrayDiskVendor.2 = STRING: "DELL " StorageManagement-MIB::arrayDiskVendor.3 = STRING: "DELL " StorageManagement-MIB::arrayDiskVendor.4 = STRING: "DELL " StorageManagement-MIB::arrayDiskState.1 = INTEGER: online(3) StorageManagement-MIB::arrayDiskState.2 = INTEGER: online(3) StorageManagement-MIB::arrayDiskState.3 = INTEGER: online(3) StorageManagement-MIB::arrayDiskState.4 = INTEGER: online(3) StorageManagement-MIB::arrayDiskProductID.1 = STRING: "ST3146755SS " StorageManagement-MIB::arrayDiskProductID.2 = STRING: "ST3146755SS " StorageManagement-MIB::arrayDiskProductID.3 = STRING: "ST3146755SS " StorageManagement-MIB::arrayDiskProductID.4 = STRING: "ST3146755SS " StorageManagement-MIB::arrayDiskSerialNo.1 = STRING: "3LN0LRL0 " StorageManagement-MIB::arrayDiskSerialNo.2 = STRING: "3LN0JYJS " StorageManagement-MIB::arrayDiskSerialNo.3 = STRING: "3LN0LR0V " StorageManagement-MIB::arrayDiskSerialNo.4 = STRING: "3LN0JH97 " StorageManagement-MIB::arrayDiskRevision.1 = STRING: "T106" StorageManagement-MIB::arrayDiskRevision.2 = STRING: "T106" StorageManagement-MIB::arrayDiskRevision.3 = STRING: "T106" StorageManagement-MIB::arrayDiskRevision.4 = STRING: "T106" StorageManagement-MIB::arrayDiskEnclosureID.1 = STRING: "0" StorageManagement-MIB::arrayDiskEnclosureID.2 = STRING: "0" StorageManagement-MIB::arrayDiskEnclosureID.3 = STRING: "0" StorageManagement-MIB::arrayDiskEnclosureID.4 = STRING: "0" StorageManagement-MIB::arrayDiskChannel.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskChannel.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskChannel.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskChannel.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskLengthInMB.1 = INTEGER: 139392 StorageManagement-MIB::arrayDiskLengthInMB.2 = INTEGER: 139392 StorageManagement-MIB::arrayDiskLengthInMB.3 = INTEGER: 139392 StorageManagement-MIB::arrayDiskLengthInMB.4 = INTEGER: 139392 StorageManagement-MIB::arrayDiskLengthInBytes.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskLengthInBytes.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskLengthInBytes.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskLengthInBytes.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInMB.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInMB.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInMB.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInMB.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInBytes.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInBytes.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInBytes.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInBytes.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskTargetID.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskTargetID.2 = INTEGER: 1 StorageManagement-MIB::arrayDiskTargetID.3 = INTEGER: 2 StorageManagement-MIB::arrayDiskTargetID.4 = INTEGER: 3 StorageManagement-MIB::arrayDiskLunID.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskLunID.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskLunID.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskLunID.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskUsedSpaceInMB.1 = INTEGER: 139392 StorageManagement-MIB::arrayDiskUsedSpaceInMB.2 = INTEGER: 139392 StorageManagement-MIB::arrayDiskUsedSpaceInMB.3 = INTEGER: 139392 StorageManagement-MIB::arrayDiskUsedSpaceInMB.4 = INTEGER: 139392 StorageManagement-MIB::arrayDiskUsedSpaceInBytes.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskUsedSpaceInBytes.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskUsedSpaceInBytes.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskUsedSpaceInBytes.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskFreeSpaceInMB.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskFreeSpaceInMB.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskFreeSpaceInMB.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskFreeSpaceInMB.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskFreeSpaceInBytes.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskFreeSpaceInBytes.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskFreeSpaceInBytes.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskFreeSpaceInBytes.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskBusType.1 = INTEGER: sas(8) StorageManagement-MIB::arrayDiskBusType.2 = INTEGER: sas(8) StorageManagement-MIB::arrayDiskBusType.3 = INTEGER: sas(8) StorageManagement-MIB::arrayDiskBusType.4 = INTEGER: sas(8) StorageManagement-MIB::arrayDiskSpareState.1 = INTEGER: notASpare(5) StorageManagement-MIB::arrayDiskSpareState.2 = INTEGER: notASpare(5) StorageManagement-MIB::arrayDiskSpareState.3 = INTEGER: notASpare(5) StorageManagement-MIB::arrayDiskSpareState.4 = INTEGER: notASpare(5) StorageManagement-MIB::arrayDiskRollUpStatus.1 = INTEGER: ok(3) StorageManagement-MIB::arrayDiskRollUpStatus.2 = INTEGER: ok(3) StorageManagement-MIB::arrayDiskRollUpStatus.3 = INTEGER: ok(3) StorageManagement-MIB::arrayDiskRollUpStatus.4 = INTEGER: ok(3) StorageManagement-MIB::arrayDiskComponentStatus.1 = INTEGER: ok(3) StorageManagement-MIB::arrayDiskComponentStatus.2 = INTEGER: ok(3) StorageManagement-MIB::arrayDiskComponentStatus.3 = INTEGER: ok(3) StorageManagement-MIB::arrayDiskComponentStatus.4 = INTEGER: ok(3) StorageManagement-MIB::arrayDiskNexusID.1 = STRING: "\\0\\0\\0\\0" StorageManagement-MIB::arrayDiskNexusID.2 = STRING: "\\0\\0\\0\\1" StorageManagement-MIB::arrayDiskNexusID.3 = STRING: "\\0\\0\\0\\2" StorageManagement-MIB::arrayDiskNexusID.4 = STRING: "\\0\\0\\0\\3" StorageManagement-MIB::arrayDiskPartNumber.1 = STRING: "SG0DR2381253172FLRL0A00 " StorageManagement-MIB::arrayDiskPartNumber.2 = STRING: "SG0DR2381253172FJYJSA00 " StorageManagement-MIB::arrayDiskPartNumber.3 = STRING: "SG0DR2381253172FLR0VA00 " StorageManagement-MIB::arrayDiskPartNumber.4 = STRING: "SG0DR2381253172FJH97A00 " StorageManagement-MIB::arrayDiskSASAddress.1 = STRING: "5000C50002380201" StorageManagement-MIB::arrayDiskSASAddress.2 = STRING: "5000C50002385B89" StorageManagement-MIB::arrayDiskSASAddress.3 = STRING: "5000C50002385AA9" StorageManagement-MIB::arrayDiskSASAddress.4 = STRING: "5000C500023841E1" StorageManagement-MIB::arrayDiskSmartAlertIndication.1 = INTEGER: no(1) StorageManagement-MIB::arrayDiskSmartAlertIndication.2 = INTEGER: no(1) StorageManagement-MIB::arrayDiskSmartAlertIndication.3 = INTEGER: no(1) StorageManagement-MIB::arrayDiskSmartAlertIndication.4 = INTEGER: no(1) StorageManagement-MIB::arrayDiskManufactureDay.1 = STRING: "07" StorageManagement-MIB::arrayDiskManufactureDay.2 = STRING: "07" StorageManagement-MIB::arrayDiskManufactureDay.3 = STRING: "07" StorageManagement-MIB::arrayDiskManufactureDay.4 = STRING: "07" StorageManagement-MIB::arrayDiskManufactureWeek.1 = STRING: "07" StorageManagement-MIB::arrayDiskManufactureWeek.2 = STRING: "07" StorageManagement-MIB::arrayDiskManufactureWeek.3 = STRING: "07" StorageManagement-MIB::arrayDiskManufactureWeek.4 = STRING: "07" StorageManagement-MIB::arrayDiskManufactureYear.1 = STRING: "2005" StorageManagement-MIB::arrayDiskManufactureYear.2 = STRING: "2005" StorageManagement-MIB::arrayDiskManufactureYear.3 = STRING: "2005" StorageManagement-MIB::arrayDiskManufactureYear.4 = STRING: "2005" StorageManagement-MIB::arrayDiskMediaType.1 = INTEGER: hdd(2) StorageManagement-MIB::arrayDiskMediaType.2 = INTEGER: hdd(2) StorageManagement-MIB::arrayDiskMediaType.3 = INTEGER: hdd(2) StorageManagement-MIB::arrayDiskMediaType.4 = INTEGER: hdd(2) StorageManagement-MIB::arrayDiskEntry.36.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskEntry.36.2 = INTEGER: 1 StorageManagement-MIB::arrayDiskEntry.36.3 = INTEGER: 1 StorageManagement-MIB::arrayDiskEntry.36.4 = INTEGER: 1 StorageManagement-MIB::arrayDiskEntry.40.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskEntry.40.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskEntry.40.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskEntry.40.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskEntry.41.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskEntry.41.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskEntry.41.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskEntry.41.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskEnclosureConnectionNumber.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionNumber.2 = INTEGER: 2 StorageManagement-MIB::arrayDiskEnclosureConnectionNumber.3 = INTEGER: 3 StorageManagement-MIB::arrayDiskEnclosureConnectionNumber.4 = INTEGER: 4 StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskName.1 = STRING: "Physical Disk 0:0:0" StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskName.2 = STRING: "Physical Disk 0:0:1" StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskName.3 = STRING: "Physical Disk 0:0:2" StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskName.4 = STRING: "Physical Disk 0:0:3" StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskNumber.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskNumber.2 = INTEGER: 2 StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskNumber.3 = INTEGER: 3 StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskNumber.4 = INTEGER: 4 StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureName.1 = STRING: "Backplane" StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureName.2 = STRING: "Backplane" StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureName.3 = STRING: "Backplane" StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureName.4 = STRING: "Backplane" StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureNumber.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureNumber.2 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureNumber.3 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureNumber.4 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionControllerName.1 = STRING: "PERC 5/i Integrated" StorageManagement-MIB::arrayDiskEnclosureConnectionControllerName.2 = STRING: "PERC 5/i Integrated" StorageManagement-MIB::arrayDiskEnclosureConnectionControllerName.3 = STRING: "PERC 5/i Integrated" StorageManagement-MIB::arrayDiskEnclosureConnectionControllerName.4 = STRING: "PERC 5/i Integrated" StorageManagement-MIB::arrayDiskEnclosureConnectionControllerNumber.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionControllerNumber.2 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionControllerNumber.3 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionControllerNumber.4 = INTEGER: 1 StorageManagement-MIB::batteryNumber.1 = INTEGER: 1 StorageManagement-MIB::batteryName.1 = STRING: "Battery 0" StorageManagement-MIB::batteryVendor.1 = STRING: "DELL" StorageManagement-MIB::batteryState.1 = INTEGER: ready(1) StorageManagement-MIB::batteryRollUpStatus.1 = INTEGER: ok(3) StorageManagement-MIB::batteryComponentStatus.1 = INTEGER: ok(3) StorageManagement-MIB::batteryNexusID.1 = STRING: "\\0\\0" StorageManagement-MIB::batteryPredictedCapacity.1 = INTEGER: ready(2) StorageManagement-MIB::batteryNextLearnTime.1 = INTEGER: 21 StorageManagement-MIB::batteryLearnState.1 = INTEGER: idle(16) StorageManagement-MIB::batteryEntry.13.1 = INTEGER: 0 StorageManagement-MIB::batteryMaxLearnDelay.1 = INTEGER: 168 StorageManagement-MIB::batteryConnectionNumber.1 = INTEGER: 1 StorageManagement-MIB::batteryConnectionBatteryName.1 = STRING: "Battery 0" StorageManagement-MIB::batteryConnectionBatteryNumber.1 = INTEGER: 1 StorageManagement-MIB::batteryConnectionControllerName.1 = STRING: "PERC 5/i Integrated" StorageManagement-MIB::batteryConnectionControllerNumber.1 = INTEGER: 1 StorageManagement-MIB::virtualDiskNumber.1 = INTEGER: 1 StorageManagement-MIB::virtualDiskName.1 = STRING: "Virtual Disk 0" StorageManagement-MIB::virtualDiskDeviceName.1 = STRING: "/dev/sda" StorageManagement-MIB::virtualDiskState.1 = INTEGER: ready(1) StorageManagement-MIB::virtualDiskLengthInMB.1 = INTEGER: 278784 StorageManagement-MIB::virtualDiskLengthInBytes.1 = INTEGER: 0 StorageManagement-MIB::virtualDiskWritePolicy.1 = INTEGER: writeBack(3) StorageManagement-MIB::virtualDiskReadPolicy.1 = INTEGER: noReadAhead(5) StorageManagement-MIB::virtualDiskCachePolicy.1 = INTEGER: not-applicable(99) StorageManagement-MIB::virtualDiskLayout.1 = INTEGER: raid-10(10) StorageManagement-MIB::virtualDiskCurStripeSizeInMB.1 = INTEGER: 0 StorageManagement-MIB::virtualDiskCurStripeSizeInBytes.1 = INTEGER: 65536 StorageManagement-MIB::virtualDiskTargetID.1 = INTEGER: 0 StorageManagement-MIB::virtualDiskRollUpStatus.1 = INTEGER: ok(3) StorageManagement-MIB::virtualDiskComponentStatus.1 = INTEGER: ok(3) StorageManagement-MIB::virtualDiskNexusID.1 = STRING: "\\0\\0" StorageManagement-MIB::virtualDiskArrayDiskType.1 = INTEGER: sas(1) StorageManagement-MIB::virtualDiskEntry.23.1 = INTEGER: 2 StorageManagement-MIB::virtualDiskEntry.24.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskLogicalConnectionNumber.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskLogicalConnectionNumber.2 = INTEGER: 2 StorageManagement-MIB::arrayDiskLogicalConnectionNumber.3 = INTEGER: 3 StorageManagement-MIB::arrayDiskLogicalConnectionNumber.4 = INTEGER: 4 StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskName.1 = STRING: "Physical Disk 0:0:0" StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskName.2 = STRING: "Physical Disk 0:0:1" StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskName.3 = STRING: "Physical Disk 0:0:2" StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskName.4 = STRING: "Physical Disk 0:0:3" StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskNumber.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskNumber.2 = INTEGER: 2 StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskNumber.3 = INTEGER: 3 StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskNumber.4 = INTEGER: 4 StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskName.1 = STRING: "Virtual Disk 0" StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskName.2 = STRING: "Virtual Disk 0" StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskName.3 = STRING: "Virtual Disk 0" StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskName.4 = STRING: "Virtual Disk 0" StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskNumber.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskNumber.2 = INTEGER: 1 StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskNumber.3 = INTEGER: 1 StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskNumber.4 = INTEGER: 1

    Read the article

  • Is my hard drive about to die?

    - by Hristo Deshev
    I have two hard drives set up as a RAID 1 array on my server (Linux, software RAID using mdadm) and one of them just got me this "present" in syslog: Nov 23 02:05:29 h2 kernel: [7305215.338153] ata1.00: exception Emask 0x0 SAct 0x1 SErr 0x0 action 0x0 Nov 23 02:05:29 h2 kernel: [7305215.338178] ata1.00: irq_stat 0x40000008 Nov 23 02:05:29 h2 kernel: [7305215.338197] ata1.00: failed command: READ FPDMA QUEUED Nov 23 02:05:29 h2 kernel: [7305215.338220] ata1.00: cmd 60/08:00:d8:df:da/00:00:3a:00:00/40 tag 0 ncq 4096 in Nov 23 02:05:29 h2 kernel: [7305215.338221] res 41/40:08:d8:df:da/00:00:3a:00:00/00 Emask 0x409 (media error) <F> Nov 23 02:05:29 h2 kernel: [7305215.338287] ata1.00: status: { DRDY ERR } Nov 23 02:05:29 h2 kernel: [7305215.338305] ata1.00: error: { UNC } Nov 23 02:05:29 h2 kernel: [7305215.358901] ata1.00: configured for UDMA/133 Nov 23 02:05:32 h2 kernel: [7305218.269054] ata1.00: exception Emask 0x0 SAct 0x1 SErr 0x0 action 0x0 Nov 23 02:05:32 h2 kernel: [7305218.269081] ata1.00: irq_stat 0x40000008 Nov 23 02:05:32 h2 kernel: [7305218.269101] ata1.00: failed command: READ FPDMA QUEUED Nov 23 02:05:32 h2 kernel: [7305218.269125] ata1.00: cmd 60/08:00:d8:df:da/00:00:3a:00:00/40 tag 0 ncq 4096 in Nov 23 02:05:32 h2 kernel: [7305218.269126] res 41/40:08:d8:df:da/00:00:3a:00:00/00 Emask 0x409 (media error) <F> Nov 23 02:05:32 h2 kernel: [7305218.269196] ata1.00: status: { DRDY ERR } Nov 23 02:05:32 h2 kernel: [7305218.269215] ata1.00: error: { UNC } Nov 23 02:05:32 h2 kernel: [7305218.341565] ata1.00: configured for UDMA/133 Nov 23 02:05:35 h2 kernel: [7305221.193342] ata1.00: exception Emask 0x0 SAct 0x1 SErr 0x0 action 0x0 Nov 23 02:05:35 h2 kernel: [7305221.193368] ata1.00: irq_stat 0x40000008 Nov 23 02:05:35 h2 kernel: [7305221.193386] ata1.00: failed command: READ FPDMA QUEUED Nov 23 02:05:35 h2 kernel: [7305221.193408] ata1.00: cmd 60/08:00:d8:df:da/00:00:3a:00:00/40 tag 0 ncq 4096 in Nov 23 02:05:35 h2 kernel: [7305221.193409] res 41/40:08:d8:df:da/00:00:3a:00:00/00 Emask 0x409 (media error) <F> Nov 23 02:05:35 h2 kernel: [7305221.193474] ata1.00: status: { DRDY ERR } Nov 23 02:05:35 h2 kernel: [7305221.193491] ata1.00: error: { UNC } Nov 23 02:05:35 h2 kernel: [7305221.388404] ata1.00: configured for UDMA/133 Nov 23 02:05:38 h2 kernel: [7305224.426316] ata1.00: exception Emask 0x0 SAct 0x1 SErr 0x0 action 0x0 Nov 23 02:05:38 h2 kernel: [7305224.426343] ata1.00: irq_stat 0x40000008 Nov 23 02:05:38 h2 kernel: [7305224.426363] ata1.00: failed command: READ FPDMA QUEUED Nov 23 02:05:38 h2 kernel: [7305224.426387] ata1.00: cmd 60/08:00:d8:df:da/00:00:3a:00:00/40 tag 0 ncq 4096 in Nov 23 02:05:38 h2 kernel: [7305224.426388] res 41/40:08:d8:df:da/00:00:3a:00:00/00 Emask 0x409 (media error) <F> Nov 23 02:05:38 h2 kernel: [7305224.426459] ata1.00: status: { DRDY ERR } Nov 23 02:05:38 h2 kernel: [7305224.426478] ata1.00: error: { UNC } Nov 23 02:05:38 h2 kernel: [7305224.498133] ata1.00: configured for UDMA/133 Nov 23 02:05:41 h2 kernel: [7305227.400583] ata1.00: exception Emask 0x0 SAct 0x1 SErr 0x0 action 0x0 Nov 23 02:05:41 h2 kernel: [7305227.400608] ata1.00: irq_stat 0x40000008 Nov 23 02:05:41 h2 kernel: [7305227.400627] ata1.00: failed command: READ FPDMA QUEUED Nov 23 02:05:41 h2 kernel: [7305227.400649] ata1.00: cmd 60/08:00:d8:df:da/00:00:3a:00:00/40 tag 0 ncq 4096 in Nov 23 02:05:41 h2 kernel: [7305227.400650] res 41/40:08:d8:df:da/00:00:3a:00:00/00 Emask 0x409 (media error) <F> Nov 23 02:05:41 h2 kernel: [7305227.400716] ata1.00: status: { DRDY ERR } Nov 23 02:05:41 h2 kernel: [7305227.400734] ata1.00: error: { UNC } Nov 23 02:05:41 h2 kernel: [7305227.472432] ata1.00: configured for UDMA/133 From what I read so far, I am not sure if read errors mean that a hard drive is dying on me (no write errors so far). I've had hard drive errors in the past and those always had errors about failing to write to specific sectors in the logs. Not this time. Should I be replacing the drive? Could something else be causing the problem? I've scheduled a smartctl -t long test that will finish in a couple of hours. I hope this will give me some more info.

    Read the article

  • e2fsck / resize2fs problems

    - by BlakBat
    I've got 6 drives (each 1.5T, all same model and firmware revision) that are part of a RAID5 array. The RAID5 makes a LVM volume group and a logical group. The latter contains only one ext3 partition. I've recently ran: e2fsck -f /dev/vg03/lv01 && resize2fs -M /dev/vg03/lv01 which exited without an error. Now when I try to mount /dev/vg03/lv01 I get: EXT3-fs error (device dm-0): ext3_check_descriptors: Block bitmap for group 30533 not in group (block 1000532368)! EXT3-fs: group descriptors corrupted! How do I get out of this predicament? This is all the info I can currently give you: fdisk -l /dev/sd[cdefgh] shows (correctly) that they are "Linux raid autodetect" but fdisk now shows: fdisk -l /dev/md0 Disk /dev/md0: 7501.5 GB, 7501495664640 bytes ... Disk identifier: 0x00000000 Disk /dev/md0 doesn't contain a valid partition table (instead of a LVM type partition) fdisk -l /dev/vg03/lv01 Disk /dev/vg03/lv01: 7501.5 GB, 7501491732480 bytes ... Disk identifier: 0x00000000 Disk /dev/vg03/lv01 doesn't contain a valid partition table (instead of a ext3 type partition) I've tried: e2fsck -fy /dev/vg03/lv01 e2fsck 1.41.12 (17-May-2010) e2fsck: Group descriptors look bad... trying backup blocks... Block bitmap for group 30533 is not in group. (block 1000532368) Relocate? yes Inode bitmap for group 30533 is not in group. (block 1000532369) Relocate? yes Pass 1: Checking inodes, blocks, and sizes Relocating group 30533's block bitmap to 1000524246... Error allocating 1 contiguous block(s) in block group 30533 for inode bitmap: Could not allocate block in ext2 filesystem e2fsck: aborted Extra information I can give you: cat /proc/mdstat Personalities : [linear] [multipath] [raid0] [raid1] [raid6] [raid5] [raid4] [raid10] md0 : active (auto-read-only) raid5 sdg1[0] sdh1[5] sdf1[4] sde1[3] sdc1[2] sdd1[1] 7325679360 blocks level 5, 128k chunk, algorithm 2 [6/6] [UUUUUU] bitmap: 1/175 pages [4KB], 4096KB chunk unused devices: Lastly, all smartctl tests (short and extendend) showed no errors on any of the disks. Should I try to resize2fs to grow /dev/vg03/lv01 and redo a e2fsck ? Should I cfdisk /dev/md0 and /dev/vg03/lv01 back to their real types? Thanks in advance for all and any help. 2011-09-20 UPDATE I issued the following commands and was able to remount the partition, but by viewing the size (df) of before and after, it seems that 1Tb of data have gone missing. By checking the MD5SUMS (from an old backup) of some files with the "same" files from the remounted partition, some errors have been detected. Commands issued to remount the partition were: dumpe2fs /dev/vg03/lv01 Block count: 1000491435<br /> Block size: 4096<br /> tune2fs -O ^has_journal /dev/vg03/lv01 resize2fs -p /dev/vg03/lv01 dumpe2fs /dev/vg03/lv01 Block count: 1831418880<br /> Block size: 4096<br /> mount -o ro,noatime /dev/vg03/lv01 /mnt/raid OK... but files have been damaged / gone missing.

    Read the article

  • LSI 9285-8e and Supermicro SC837E26-RJBOD1 duplicate enclosure ID and slot numbers

    - by Andy Shinn
    I am working with 2 x Supermicro SC837E26-RJBOD1 chassis connected to a single LSI 9285-8e card in a Supermicro 1U host. There are 28 drives in each chassis for a total of 56 drives in 28 RAID1 mirrors. The problem I am running in to is that there are duplicate slots for the 2 chassis (the slots list twice and only go from 0 to 27). All the drives also show the same enclosure ID (ID 36). However, MegaCLI -encinfo lists the 2 enclosures correctly (ID 36 and ID 65). My question is, why would this happen? Is there an option I am missing to use 2 enclosures effectively? This is blocking me rebuilding a drive that failed in slot 11 since I can only specify enclosure and slot as parameters to replace a drive. When I do this, it picks the wrong slot 11 (device ID 46 instead of device ID 19). Adapter #1 is the LSI 9285-8e, adapter #0 (which I removed due to space limitations) is the onboard LSI. Adapter information: Adapter #1 ============================================================================== Versions ================ Product Name : LSI MegaRAID SAS 9285-8e Serial No : SV12704804 FW Package Build: 23.1.1-0004 Mfg. Data ================ Mfg. Date : 06/30/11 Rework Date : 00/00/00 Revision No : 00A Battery FRU : N/A Image Versions in Flash: ================ BIOS Version : 5.25.00_4.11.05.00_0x05040000 WebBIOS Version : 6.1-20-e_20-Rel Preboot CLI Version: 05.01-04:#%00001 FW Version : 3.140.15-1320 NVDATA Version : 2.1106.03-0051 Boot Block Version : 2.04.00.00-0001 BOOT Version : 06.253.57.219 Pending Images in Flash ================ None PCI Info ================ Vendor Id : 1000 Device Id : 005b SubVendorId : 1000 SubDeviceId : 9285 Host Interface : PCIE ChipRevision : B0 Number of Frontend Port: 0 Device Interface : PCIE Number of Backend Port: 8 Port : Address 0 5003048000ee8e7f 1 5003048000ee8a7f 2 0000000000000000 3 0000000000000000 4 0000000000000000 5 0000000000000000 6 0000000000000000 7 0000000000000000 HW Configuration ================ SAS Address : 500605b0038f9210 BBU : Present Alarm : Present NVRAM : Present Serial Debugger : Present Memory : Present Flash : Present Memory Size : 1024MB TPM : Absent On board Expander: Absent Upgrade Key : Absent Temperature sensor for ROC : Present Temperature sensor for controller : Absent ROC temperature : 70 degree Celcius Settings ================ Current Time : 18:24:36 3/13, 2012 Predictive Fail Poll Interval : 300sec Interrupt Throttle Active Count : 16 Interrupt Throttle Completion : 50us Rebuild Rate : 30% PR Rate : 30% BGI Rate : 30% Check Consistency Rate : 30% Reconstruction Rate : 30% Cache Flush Interval : 4s Max Drives to Spinup at One Time : 2 Delay Among Spinup Groups : 12s Physical Drive Coercion Mode : Disabled Cluster Mode : Disabled Alarm : Enabled Auto Rebuild : Enabled Battery Warning : Enabled Ecc Bucket Size : 15 Ecc Bucket Leak Rate : 1440 Minutes Restore HotSpare on Insertion : Disabled Expose Enclosure Devices : Enabled Maintain PD Fail History : Enabled Host Request Reordering : Enabled Auto Detect BackPlane Enabled : SGPIO/i2c SEP Load Balance Mode : Auto Use FDE Only : No Security Key Assigned : No Security Key Failed : No Security Key Not Backedup : No Default LD PowerSave Policy : Controller Defined Maximum number of direct attached drives to spin up in 1 min : 10 Any Offline VD Cache Preserved : No Allow Boot with Preserved Cache : No Disable Online Controller Reset : No PFK in NVRAM : No Use disk activity for locate : No Capabilities ================ RAID Level Supported : RAID0, RAID1, RAID5, RAID6, RAID00, RAID10, RAID50, RAID60, PRL 11, PRL 11 with spanning, SRL 3 supported, PRL11-RLQ0 DDF layout with no span, PRL11-RLQ0 DDF layout with span Supported Drives : SAS, SATA Allowed Mixing: Mix in Enclosure Allowed Mix of SAS/SATA of HDD type in VD Allowed Status ================ ECC Bucket Count : 0 Limitations ================ Max Arms Per VD : 32 Max Spans Per VD : 8 Max Arrays : 128 Max Number of VDs : 64 Max Parallel Commands : 1008 Max SGE Count : 60 Max Data Transfer Size : 8192 sectors Max Strips PerIO : 42 Max LD per array : 16 Min Strip Size : 8 KB Max Strip Size : 1.0 MB Max Configurable CacheCade Size: 0 GB Current Size of CacheCade : 0 GB Current Size of FW Cache : 887 MB Device Present ================ Virtual Drives : 28 Degraded : 0 Offline : 0 Physical Devices : 59 Disks : 56 Critical Disks : 0 Failed Disks : 0 Supported Adapter Operations ================ Rebuild Rate : Yes CC Rate : Yes BGI Rate : Yes Reconstruct Rate : Yes Patrol Read Rate : Yes Alarm Control : Yes Cluster Support : No BBU : No Spanning : Yes Dedicated Hot Spare : Yes Revertible Hot Spares : Yes Foreign Config Import : Yes Self Diagnostic : Yes Allow Mixed Redundancy on Array : No Global Hot Spares : Yes Deny SCSI Passthrough : No Deny SMP Passthrough : No Deny STP Passthrough : No Support Security : No Snapshot Enabled : No Support the OCE without adding drives : Yes Support PFK : Yes Support PI : No Support Boot Time PFK Change : Yes Disable Online PFK Change : No PFK TrailTime Remaining : 0 days 0 hours Support Shield State : Yes Block SSD Write Disk Cache Change: Yes Supported VD Operations ================ Read Policy : Yes Write Policy : Yes IO Policy : Yes Access Policy : Yes Disk Cache Policy : Yes Reconstruction : Yes Deny Locate : No Deny CC : No Allow Ctrl Encryption: No Enable LDBBM : No Support Breakmirror : No Power Savings : Yes Supported PD Operations ================ Force Online : Yes Force Offline : Yes Force Rebuild : Yes Deny Force Failed : No Deny Force Good/Bad : No Deny Missing Replace : No Deny Clear : No Deny Locate : No Support Temperature : Yes Disable Copyback : No Enable JBOD : No Enable Copyback on SMART : No Enable Copyback to SSD on SMART Error : Yes Enable SSD Patrol Read : No PR Correct Unconfigured Areas : Yes Enable Spin Down of UnConfigured Drives : Yes Disable Spin Down of hot spares : No Spin Down time : 30 T10 Power State : Yes Error Counters ================ Memory Correctable Errors : 0 Memory Uncorrectable Errors : 0 Cluster Information ================ Cluster Permitted : No Cluster Active : No Default Settings ================ Phy Polarity : 0 Phy PolaritySplit : 0 Background Rate : 30 Strip Size : 64kB Flush Time : 4 seconds Write Policy : WB Read Policy : Adaptive Cache When BBU Bad : Disabled Cached IO : No SMART Mode : Mode 6 Alarm Disable : Yes Coercion Mode : None ZCR Config : Unknown Dirty LED Shows Drive Activity : No BIOS Continue on Error : No Spin Down Mode : None Allowed Device Type : SAS/SATA Mix Allow Mix in Enclosure : Yes Allow HDD SAS/SATA Mix in VD : Yes Allow SSD SAS/SATA Mix in VD : No Allow HDD/SSD Mix in VD : No Allow SATA in Cluster : No Max Chained Enclosures : 16 Disable Ctrl-R : Yes Enable Web BIOS : Yes Direct PD Mapping : No BIOS Enumerate VDs : Yes Restore Hot Spare on Insertion : No Expose Enclosure Devices : Yes Maintain PD Fail History : Yes Disable Puncturing : No Zero Based Enclosure Enumeration : No PreBoot CLI Enabled : Yes LED Show Drive Activity : Yes Cluster Disable : Yes SAS Disable : No Auto Detect BackPlane Enable : SGPIO/i2c SEP Use FDE Only : No Enable Led Header : No Delay during POST : 0 EnableCrashDump : No Disable Online Controller Reset : No EnableLDBBM : No Un-Certified Hard Disk Drives : Allow Treat Single span R1E as R10 : No Max LD per array : 16 Power Saving option : Don't Auto spin down Configured Drives Max power savings option is not allowed for LDs. Only T10 power conditions are to be used. Default spin down time in minutes: 30 Enable JBOD : No TTY Log In Flash : No Auto Enhanced Import : No BreakMirror RAID Support : No Disable Join Mirror : No Enable Shield State : Yes Time taken to detect CME : 60s Exit Code: 0x00 Enclosure information: # /opt/MegaRAID/MegaCli/MegaCli64 -encinfo -a1 Number of enclosures on adapter 1 -- 3 Enclosure 0: Device ID : 36 Number of Slots : 28 Number of Power Supplies : 2 Number of Fans : 3 Number of Temperature Sensors : 1 Number of Alarms : 1 Number of SIM Modules : 0 Number of Physical Drives : 28 Status : Normal Position : 1 Connector Name : Port B Enclosure type : SES VendorId is LSI CORP and Product Id is SAS2X36 VendorID and Product ID didnt match FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : 65 Inquiry data : Vendor Identification : LSI CORP Product Identification : SAS2X36 Product Revision Level : 0718 Vendor Specific : x36-55.7.24.1 Number of Voltage Sensors :2 Voltage Sensor :0 Voltage Sensor Status :OK Voltage Value :5020 milli volts Voltage Sensor :1 Voltage Sensor Status :OK Voltage Value :11820 milli volts Number of Power Supplies : 2 Power Supply : 0 Power Supply Status : OK Power Supply : 1 Power Supply Status : OK Number of Fans : 3 Fan : 0 Fan Speed :Low Speed Fan Status : OK Fan : 1 Fan Speed :Low Speed Fan Status : OK Fan : 2 Fan Speed :Low Speed Fan Status : OK Number of Temperature Sensors : 1 Temp Sensor : 0 Temperature : 48 Temperature Sensor Status : OK Number of Chassis : 1 Chassis : 0 Chassis Status : OK Enclosure 1: Device ID : 65 Number of Slots : 28 Number of Power Supplies : 2 Number of Fans : 3 Number of Temperature Sensors : 1 Number of Alarms : 1 Number of SIM Modules : 0 Number of Physical Drives : 28 Status : Normal Position : 1 Connector Name : Port A Enclosure type : SES VendorId is LSI CORP and Product Id is SAS2X36 VendorID and Product ID didnt match FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : 36 Inquiry data : Vendor Identification : LSI CORP Product Identification : SAS2X36 Product Revision Level : 0718 Vendor Specific : x36-55.7.24.1 Number of Voltage Sensors :2 Voltage Sensor :0 Voltage Sensor Status :OK Voltage Value :5020 milli volts Voltage Sensor :1 Voltage Sensor Status :OK Voltage Value :11760 milli volts Number of Power Supplies : 2 Power Supply : 0 Power Supply Status : OK Power Supply : 1 Power Supply Status : OK Number of Fans : 3 Fan : 0 Fan Speed :Low Speed Fan Status : OK Fan : 1 Fan Speed :Low Speed Fan Status : OK Fan : 2 Fan Speed :Low Speed Fan Status : OK Number of Temperature Sensors : 1 Temp Sensor : 0 Temperature : 47 Temperature Sensor Status : OK Number of Chassis : 1 Chassis : 0 Chassis Status : OK Enclosure 2: Device ID : 252 Number of Slots : 8 Number of Power Supplies : 0 Number of Fans : 0 Number of Temperature Sensors : 0 Number of Alarms : 0 Number of SIM Modules : 1 Number of Physical Drives : 0 Status : Normal Position : 1 Connector Name : Unavailable Enclosure type : SGPIO Failed in first Inquiry commnad FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : Unavailable Inquiry data : Vendor Identification : LSI Product Identification : SGPIO Product Revision Level : N/A Vendor Specific : Exit Code: 0x00 Now, notice that each slot 11 device shows an enclosure ID of 36, I think this is where the discrepancy happens. One should be 36. But the other should be on enclosure 65. Drives in slot 11: Enclosure Device ID: 36 Slot Number: 11 Drive's postion: DiskGroup: 5, Span: 0, Arm: 1 Enclosure position: 0 Device Id: 48 WWN: Sequence Number: 11 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Firmware state: Online, Spun Up Is Commissioned Spare : YES Device Firmware Level: A5C0 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5003048000ee8a53 Connected Port Number: 1(path0) Inquiry Data: MJ1311YNG6YYXAHitachi HDS5C3030ALA630 MEAOA5C0 FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :30C (86.00 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Drive's write cache : Disabled Drive's NCQ setting : Enabled Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No Enclosure Device ID: 36 Slot Number: 11 Drive's postion: DiskGroup: 19, Span: 0, Arm: 1 Enclosure position: 0 Device Id: 19 WWN: Sequence Number: 4 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Firmware state: Online, Spun Up Is Commissioned Spare : NO Device Firmware Level: A580 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5003048000ee8e53 Connected Port Number: 0(path0) Inquiry Data: MJ1313YNG1VA5CHitachi HDS5C3030ALA630 MEAOA580 FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :30C (86.00 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Drive's write cache : Disabled Drive's NCQ setting : Enabled Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No Update 06/28/12: I finally have some new information about (what we think) the root cause of this problem so I thought I would share. After getting in contact with a very knowledgeable Supermicro tech, they provided us with a tool called Xflash (doesn't appear to be readily available on their FTP). When we gathered some information using this utility, my colleague found something very strange: root@mogile2 test]# ./xflash.dat -i get avail Initializing Interface. Expander: SAS2X36 (SAS2x36) 1) SAS2X36 (SAS2x36) (50030480:00EE917F) (0.0.0.0) 2) SAS2X36 (SAS2x36) (50030480:00E9D67F) (0.0.0.0) 3) SAS2X36 (SAS2x36) (50030480:0112D97F) (0.0.0.0) This lists the connected enclosures. You see the 3 connected (we have since added a 3rd and a 4th which is not yet showing up) with their respective SAS address / WWN (50030480:00EE917F). Now we can use this address to get information on the individual enclosures: [root@mogile2 test]# ./xflash.dat -i 5003048000EE917F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:00EE917F Enclosure Logical Id: 50030480:0000007F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 [root@mogile2 test]# ./xflash.dat -i 5003048000E9D67F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:00E9D67F Enclosure Logical Id: 50030480:0000007F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 [root@mogile2 test]# ./xflash.dat -i 500304800112D97F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:0112D97F Enclosure Logical Id: 50030480:0112D97F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 Did you catch it? The first 2 enclosures logical ID is partially masked out where the 3rd one (which has a correct unique enclosure ID) is not. We pointed this out to Supermicro and were able to confirm that this address is supposed to be set during manufacturing and there was a problem with a certain batch of these enclosures where the logical ID was not set. We believe that the RAID controller is determining the ID based on the logical ID and since our first 2 enclosures have the same logical ID, they get the same enclosure ID. We also confirmed that 0000007F is the default which comes from LSI as an ID. The next pointer that helps confirm this could be a manufacturing problem with a run of JBODs is the fact that all 6 of the enclosures that have this problem begin with 00E. I believe that between 00E8 and 00EE Supermicro forgot to program the logical IDs correctly and neglected to recall or fix the problem post production. Fortunately for us, there is a tool to manage the WWN and logical ID of the devices from Supermicro: ftp://ftp.supermicro.com/utility/ExpanderXtools_Lite/. Our next step is to schedule a shutdown of these JBODs (after data migration) and reprogram the logical ID and see if it solves the problem. Update 06/28/12 #2: I just discovered this FAQ at Supermicro while Google searching for "lsi 0000007f": http://www.supermicro.com/support/faqs/faq.cfm?faq=11805. I still don't understand why, in the last several times we contacted Supermicro, they would have never directed us to this article :\

    Read the article

  • Dell Poweredge R410 replace PERC S100 with PERC 6i

    - by Robe Eleckers
    I want to replace the PERC S100 RAID Controller with a PERC6i to be able to use 4 SAS harddrives instead of only SATA drives. What exactly do I need for this, what I've got so far: PERC6i PCIe x8 card. 4 x SAS 300GB 15000rpm drives Some questions I have Do I need a different backplane to accomodate the SAS disks? If so, what kind of backplane? Do I need a special cable to hookup the PERC6i with the backplane? If so, what kind of cable? Thanks.

    Read the article

  • RAIDZ vs RAID1+0

    - by Hiro2k
    Hi guys I just got 4 SSDs for my FreeNAS box. This server is only used to serve a single iSCSI extent to my Citrix XenServer pool and was wondering if I should setup them up in a RAIDZ or a RAID 1+0 configuration. This isn't used for anything in production, just for my test lab so I'm not sure which one is going to be better in this scenario. Will I see a major difference in speed or reliability? Currently the server has three 500GB Western Digital Blue drives and it's dog slow when I deploy a new version of our software on it, hence the upgrade.

    Read the article

  • Strange performance issue with Dell R7610 and LSI 2208 RAID controller

    - by GregC
    Connecting controller to any of the three PCIe x16 slots yield choppy read performance around 750 MB/sec Lowly PCIe x4 slot yields steady 1.2 GB/sec read Given same files, same Windows Server 2008 R2 OS, same RAID6 24-disk Seagate ES.2 3TB array on LSI 9286-8e, same Dell R7610 Precision Workstation with A03 BIOS, same W5000 graphics card (no other cards), same settings etc. I see super-low CPU utilization in both cases. SiSoft Sandra reports x8 at 5GT/sec in x16 slot, and x4 at 5GT/sec in x4 slot, as expected. I'd like to be able to rely on the sheer speed of x16 slots. What gives? What can I try? Any ideas? Please assist Cross-posted from http://en.community.dell.com/support-forums/desktop/f/3514/t/19526990.aspx Follow-up information We did some more performance testing with reading from 8 SSDs, connected directly (without an expander chip). This means that both SAS cables were utilized. We saw nearly double performance, but it varied from run to run: {2.0, 1.8, 1.6, and 1.4 GB/sec were observed, then performance jumped back up to 2.0}. The SSD RAID0 tests were conducted in a x16 PCIe slot, all other variables kept the same. It seems to me that we were getting double the performance of HDD-based RAID6 array. Just for reference: maximum possible read burst speed over single channel of SAS 6Gb/sec is 570 MB/sec due to 8b/10b encoding and protocol limitations (SAS cable provides four such channels).

    Read the article

  • How to know which block device maps to which physical drive

    - by Karolis T.
    I have a server with software RAID 1, two hot-swap sata disks. One hard drive started showing errors, I'm thinking about removing and replacing it, only problem is that I have no idea which of the two correspond to which devices. And I can't shut the server down to find out. I have /dev/sda and /dev/sdb, /dev/sda is the failing one. Thought about doing something along the lines # mdadm --manage /dev/md0 --remove /dev/sda1 then somehow stop/suspend the drive using tuning software and try to listen which of the two stopped, but that's not gonna work in a noisy server environment. Drive panels have no LEDs. Thanks for any ideas!

    Read the article

  • ZFS: Mirror vs. RAID-Z

    - by John Clayton
    I'm planning on building a file server using OpenSolaris and ZFS that will provide two primary services - be an iSCSI target for XenServer virtual machines & be a general home file server. The hardware I'm looking at includes 2x 4-port SATA controllers, 2x small boot drives (one on each controller), and 4x big drives for storage. This allows one free port per controller for upgrading the array down the road. Where I'm a little confused is how to setup the storage drives. For performance, mirroring appears to be king. I'm having a hard time seeing what the benefit would be of using RAIDZ over mirroring would be. With this setup I can see two options - two mirrored pools in one stripe, or RAIDZ2. Both should protect against 2 drive failures, and/or one controller failure...the only benefit of RAIDZ2 would be that any 2 drives could fail. The storage should be 50% of capacity in both cases, but the first should have much better performance, right? The other thing I'm trying to wrap my mind around is the benefit of mirrored arrays with more than two devices. For data integrity what, if any, would be the benefit of a RAIDZ over a three-way mirror? Since ZFS maintains file integrity what does RAIDZ bring to the table...doesn't ZFS's integrity checks negate the value of RAIDZ's parity?

    Read the article

< Previous Page | 31 32 33 34 35 36 37 38 39 40 41 42  | Next Page >