Search Results

Search found 7371 results on 295 pages for 'raid card'.

Page 35/295 | < Previous Page | 31 32 33 34 35 36 37 38 39 40 41 42  | Next Page >

  • Disaster Recovery Plan&ndash;Rebuild System Disk (Dell Server 2900 with PERC RAID controller)

    - by Jim Lahman
    Goal: Since the system disk is a RAID 1 mirrored set, we can rebuild the shadow set by replacing one of the good sets with a blank disk Steps Shutdown and power down server Remove the disk from bay 9, which is part of the system shadow set. Put this disk on the shelf Insert blank/old disk into the empty bay     Label the new disk before inserting it into the empty bay       Power up server During the booting process, the following message appears: “Some configured disks have been removed from your system…”       Press ‘C’ to Load Configuration utility             Press 'Y' to confirm to load the foreign configuration       In this example, the system shadow set is Disk Group 2.  (Before proceeding, confirm this is the disk group in your case).  Expanding the physical disks shows a disk in bay 8 and a missing disk in bay 9.  This is correct.   Now, we have to include the new inserted disk in this group       RAID controller reporting bay 9 is empty       There may be times when the new disk is seen as a foreign disk.  In this case, do the following:     Foreign disk is reported in bay 9 CTRL-N (Next Page) to Foreign Mgt All the disk groups will be displayed.  Typically, the disk group containing the foreign disk will be grey.  To remove the foreign disk Highlight Controller Press F2 Select Foreign Select Clear (do NOT import the configuration!)       Clear the foreign configuration Now the disk can be brought into the system shadow set disk group as a hot spare   To include the newly inserted disk into the system shadowset disk group, it must be brought in as a hot spare Highlight Disk Group 2 (VD Management) Hit F2 Select 'Manage Ded. HS'     Manage dedicated hot swap Select the disk in bay 9 (Hit space bar to select) Tab to 'OK'.  Hit the return key     Select hot spare to bring into RAID 1 mirror set   Rebuild automatically commences     Rebuild in process   Restart now or restart after rebuild is completed

    Read the article

  • ASUS EAH5450 Graphics Card (ATI Radeon HD5450 - 1 GB DDR3) on Windows 2003? Anybody got it to work?

    - by JJarava
    Hi all! I've just bought an ASUS EAH5450 Graphics Card (ATI Radeon HD5450, 1 GB DDR3) for my main system, but I haven't been able to make it work under Windows 2003 (my OS in that system). When I plugged the card, I got a couple of "installing drivers" prompt for things such as "ATI High Definition Audio Device" that got themselves sorted out of the Internet, and then a "Standard VGA Graphics Adapter". The CD that came with the card installs something called "ATI Catalyst Install Manager" and .net 2.0, but no drivers. I've downloaded the latest (WinXP 32bits) drivers from ATI, and the experience is the same: I don't get any drivers installed. My Motherboard is an ASUS A8N-SLI with nVidia nForce 4 chipset (for an Athlon 64X2, somewhat old), but my previous card was an ATi Radeon X700, so it's been working with ATI cards before. On POST, during boot I see a "Display Card" Device (Vendor ID 1002-68F9-0300) and a "Multimedia Device" (1002-AA68-0403), and when viewing the properties of the "Standard VGA", they match the device ID. Any hints? I'd really hate having to get rid of the card, and I'm sure it's not that strange what I'm trying to do...

    Read the article

  • 3 monitors + a TV on a single card with Eyefinity?

    - by Paul Accisano
    Greetings all, Right now I have a fairly standard video card with 2 DVI ports, one powering my single monitor and another powering my HDTV (with a DVI-to-HDMI cable), which are in separate rooms. I never need to have my monitor and TV active at the same time. I'm looking into a possible computer upgrade. I'd like to know if the following situation is possible. I want three monitors on my desk powered by a single card, which I hear these new Eyefinity cards are capable of. But, I also want my TV hooked up. At any given time, I would want either my three monitors active or my TV active, never both at once. So it seems to me it might be possible to do this all a single 3-port card with a splitter of some kind. Is this possible? What hardware would I need? Thanks!

    Read the article

  • Does upgrading RAM causes increase in Graphic card's share?

    - by A.S.
    I have asked this question on Ask Ubuntu, and I was suggested to Upgrade RAM from most voted answers. But I got a point about my graphics card. Since, I can upgrade RAM and not graphics card, Does upgrading RAM also cause graphics memory to increase. To clear the point: My specs are given below: Laptop : Lenovo 3000 Y410. (bought in 2008 October) RAM: 1 GB (DDR2) External Graphics (Dedicated): N/A Internal Graphics (Shared): 256 MB Graphics Chipset: Intel GMA X3100 My Question is: If I increase my RAM to 3 GB, will it increase graphics cards share of the Memory. In other word, If graphics card shares 256 MB in 1GB RAM, will it share more, when I upgrade the RAM into 2GB or more ? Authentic resource link will be much appreciated I have recently known that, My chipset GMA X3100 can address 384 MB of RAM. So the question.

    Read the article

  • VMWare Setup with 2 Servers and a DAS (DELL MD3220)

    - by Kumala
    I am planning to use a VMWare based setup consisting of two VMWare servers (2 CPU, 256GB Memory) and a DAS (DELL MD3220 with 24x900GB disks). The virtual machines will be half running MS SQL databases (Application, Sharepoint, BI) and the other half of the VM will be file services, IIS. To enhance the capacity of the storage, we'll be adding a MD1220 enclosure with another 24x900GB to the MD3220. Both DAS will have 2 controllers. Our current measured IOPS is 1000 IOPS average, 7000 IOPS peak (those happen maybe twice per hour). We are in the planning phase now and are looking at the proper setup of the disks. The intention is to setup up both DAS one of the DAS with RAID 10 only and the other DAS with RAID 5. That will allow us to put the applications on the DAS that supports the application performance needs best. Question is how best to partition the two DASs to get best possible IOPS/MBps, each DAS will have to have 2 hot spares? For the RAID 5 Setup: Generally speaking, would it be better to have one single disk group across all 22 disks (24 - 2 hot spares) with both controllers assigned to the one disk group or is it better to have 2 disk groups each 11 disks, assigned to one of the two controllers? Same question for the RAID 10 setup: The plan is: 2 disks for logs (Raid 1), 2 Hotspare and 20 disks for RAID 10. Option 1: 5 * 4 disks (RAID 10), with two groups assigned to 1 controller and 3 groups to the other controller Option 2: One large RAID 10 across all the disks and have both controllers assigned to the same group? I would assume that there is no right or wrong, but it all depends very much on the specific application behaviour, so I am looking for some general ideas what the pros and cons are of the different options. IF there are other meaningful options, feel free to propose them.

    Read the article

  • Trying to get a PC to boot off a bootable SD card that is inside an USB attached Android device.

    - by Cyril
    First, I'd like to make myself look less a madman than I may have appeared to be. I wanted to have a bootable USB stick with me at all times, but it's less convenient because it's an extra object and it's easier to lose, forget etc. Then I thought, I have an Android phone, and it has a micro SD in it; perfect. Not all PC's can boot off a card reader, but the phone itself is a card reader when attached as a disk drive. Or at least so I thought. Turns out that my netbook BIOS (tested on Asus eeePC) refuses to see it as an external harddrive; it only recognizes it as a generic USB device and doesn't offer an option to boot from it. The device has a name "Android phone" or smth, so it seems to me that it doesn't work as a "pure" card reader, and instead still manifests itself as a phone. Can it be somehow overridden?

    Read the article

  • Motherboard warning lights when plugging in a display port cord to graphics card?

    - by rllr
    Earlier today, my computer spontaneously shut itself off and refused to turn back on. I tested my PSU and it's operating fine. I unplugged everything and let it sit for a while and it started to make a high pitched coil whine/hiss. When I came back an hour later and plugged in only the power cord, it turned on without any issues. After some troubleshooting, I noticed my motherboard (Intel D975XBX2) has a red CPU led and VR led that come on whenever I plug my monitor into my graphics card via display port. DVI does not cause a similar issue. I was running three monitors off the card, so I need both DVI ports and the display port working. Is it likely my graphics card needs to be replaced, or should I be looking elsewhere to resolve this issue?

    Read the article

  • Is the cooling fan on a 2004 graphics card really necessary?

    - by Andrew
    I have an old GeForce 6600 card in my computer, circa 2004. Recently the fan has started playing up and making loud irritating noises. I've tried oiling it with no luck. This is the second fan I've put on the card, the stock one broke ages ago. Is a card this old really likely to need a cooling fan or can I remove it altogether? It has a decent heatsink on the chip but there's not a lot of airflow in that part of the box. Edit: I should add that I seem to remember most mid range graphics cards at the time I bought that didn't have fans (pretty sure they had heatsinks only), which is why I'm wondering.

    Read the article

  • How to tell, before buying, if a given graphics card will play Full HD video?

    - by Dominykas Mostauskis
    I am looking for the cheapest video card that would be capable of smooth playback of Full HD (1080p) video on a Full HD screen. An answer by @Mikhail on a related question briefly mentioned that: performance of video playback is largely dependent on the video accelerators present [in the card] Is this true? Could anyone expand on that? Are there any benchmarks or specifications that could be used to tell if a given (low-end) card can play Full HD video smoothly? Benchmarks I encountered are oriented towards computer games, and using them to evaluate video playback performance may be less-than-optimal, I imagine.

    Read the article

  • Non-volatile cache RAID controllers: what kind of protection is there against NVCACHE failure?

    - by astrostl
    The battery back-up (BBU) model: admin enables write-back cache with BBU writes are cached to the RAID controller's RAM (major performance benefit) the battery saves uncommitted and cached data in the event of a power loss (reliability) If I lose power and come back within a day or so, my data should be both complete and uncorrupted. The downside to this is that, if the battery is dead or low, OR EVEN IF IT IS IN A RELEARN CYCLE (drain/charge loops to ensure the battery's health), the controller reverts to write-through mode and performance will suffer. What's more, the relearn cycles are usually automated on a schedule which may or may not happen in the middle of big traffic. So, that has to be manually disabled and manually scheduled for off-hours if it's a concern. Annoying either way. NV caches have capacitors with a sufficient charge to commit any uncommitted-to-disk data to flash. Not only is that more survivable in longer loss situations, but you don't have to concern yourself with battery death, wear-out, or relearning. All of that sounds great to me. What doesn't sound great to me is the prospect of that flash module having an issue, though. What if it's completely hosed? What if it's only partially hosed? A bit corrupted at the edges? Relearn cycles can tell when something like a simple battery is failing, but is there a similar process to verify that the flash is functional? I'm just far more trusting of a battery, warts and all. I know the card's RAM can fail, the card itself can fail - that's common territory, though. In case you didn't guess, yeah, I've experienced a shocking-to-me amount of flash/SSD/etc. failure :)

    Read the article

  • Debian: Disable software Raid?

    - by DebFo
    Hey, I own a server with 2 hdds and I used a debian raid installation template. Know I want to reinstall my server and don't want raid anymore to have more space. My provider wants money to change the template to a non-raid debian one. Is there a way to disable software raid on linux after a fresh installation? Thanks

    Read the article

  • Should I buy matching hard drives for a NAS RAID 1 array?

    - by Jamie Ide
    I'm planning to buy a NAS (network attached storage) box and I've picked the Synology DS209. I want to set up a RAID 1 array and I'm wondering if I should buy a matching pair of hard drives or if it would be better to buy from different manufacturers. I'm concerned that a matching pair would be more likely to fail at the same time.

    Read the article

  • Dell PowerEdge R720 - Corrupted RAID

    - by BT643
    Apologies in advance for the lengthy question. We have a Dell PowerEdge R720 server with: 2 x 136GB SAS drives in RAID 1 for the OS (Ubuntu Server 12.04) 6 x 3TB SATA drives in RAID 5 for data A few days ago we were getting errors when trying to access files on the large RAID 5 partition. We rebooted the server and got a message about the raid controller has found a foriegn config. We've had this before, and just needed to use Dell's RAID configuration utility to import foreign config on the RAID. Last time this worked, but this time, it started doing a disk check then we got this: FSCK has returned the following: "/dev/sdb1 inode 364738 has a bad extended attribute block 7 /dev/sdb1 unexpected inconsistency run fsck manually (i.e without -a or -p options) MOUNTALL fsck /ourdatapartition [1019] terminated with status 4 MOUNTALL filesystem has errors /ourdatapartition errors where found while checking the disk drive for /ourdatapartition Press F to fix errors, I to Ignore or M for Manual Recovery" We pressed F to try and fix the errors, but it eventually errored with: Inode 275841084, i_blocks is 167080, should be 0. Fix? yes Inode 275841141 has an invalid extend node (blk 2206761006, lblk 0) Clear? yes Inode 275841141, i_blocks is 227872, should be 0. Fix? yes Inode 275842303 has an invalid extend node (blk 2206760975, lblk 0) Clear? yes .... Error storing directory block information (inode=275906766, block=0, num=2699516178): Memory allocation failed /dev/sdb1: ***** FILE SYSTEM WAS MODIFIED ***** e2fsck: aborted /dev/sdb1: ***** FILE SYSTEM WAS MODIFIED ***** mountall: fsck /ourdatapartition [1286] terminated with status 9 mountall: Unrecoverable fsck error: /ourdatapartition We noticed one of the drive lights was not lit at all, and thought this may have failed and be the problem. We replaced the drive with a spare, and tried "F" to repair it again, but we keep just getting the same error as above. In the RAID configuration utility, all drives show as "online" and "optimal". We do have this data on another replicated server, so we're not worried about "recovering" anything, we just want to get the system back online asap. The server has 64 or 32GB memory, can't remember off the top of my head, but either way, with a 14TB RAID, I think it may still not be enough. Thanks EDIT - I checked the memory usage while fsck was running as suggested and after 2 or 3 minutes, it looked like this, using up nearly all of our servers memory: When it failed after 5 minutes or so with the error in my post, the memory immediately freed up again:

    Read the article

  • How to know which disk has failed on a Mirrored Raid? marked as DR0 [migrated]

    - by Saariko
    Our 2ndry DC, which is on a W2K8R2 Mirrored software raid has lost it's sync, and disk management displays the failed redundancy error How do I know which of the disks has failed? (beside to try and replace one - and see if it loads and syncs) On the device manager, under disks I see both disks, one of them has an icon of: Disable, while the other doesn't Event log displays an event id 7 - bad block on Hard disk DR0 The thing is that looking in device manager, both disks are located in '0' location, which is bizzare

    Read the article

  • How to know which disk has failed on a Mirrored Raid? marked as DR0

    - by Saariko
    Our 2ndry DC, which is on a W2K8R2 Mirrored software raid has lost it's sync, and disk management displays the failed redundancy error How do I know which of the disks has failed? (beside to try and replace one - and see if it loads and syncs) On the device manager, under disks I see both disks, one of them has an icon of: Disable, while the other doesn't Event log displays an event id 7 - bad block on Hard disk DR0 The thing is that looking in device manager, both disks are located in '0' location, which is bizzare

    Read the article

  • Is it possible to use Linux as a Fibre Channel Raid Disk Box?

    - by SvenW
    You probably all know the relatively simple RAID boxes exporting a bunch of SATA disks as one big drive via FC, SAS or iSCSI, like the HP StorageWorks MSA2000, Infortrends EonStore series or many different other models from different manufacturers. Is it possible to create such a device with Linux, a few disks and an FC controller, using the controller in the reverse direction than usual? This would come handy to test some ideas and concepts in an emerging SAN environment.

    Read the article

  • Is data=journal on a separate device on Ext4 as good as using a RAID controller with battery backed cache for file system consistency?

    - by Jeff Strunk
    It seems to me that data=journal prevents file system inconsistency in the case of power failure. Using it with a dedicated journal device mitigates the performance penalty of writing the data twice. A power outage would still lose the data that is currently being written to the journal, but the file system on disk would always be consistent. If that amount of loss is acceptable, is a RAID controller with battery backed cache really worthwhile?

    Read the article

  • How to have 3 operating systems on a mirror RAID 1.

    - by Chris_45
    How do one proceed if I want to have 3 Operating Systems: Windows 7, Ubuntu, Debian plus a swap partion, all in all 4 partitions? Lets say I have 2 disks, each 640 GB and make room - 300 GB for Windows 7, 160 GB Ubuntu, 160 GB Debian and the rest for swap 20 GB. Where do I make these partitions, do I first make one big raid array 1 in BIOS and then partition when Windows 7 is installed or do I already in BIOS make these 4 partitions?

    Read the article

  • How to run 2 SSD drives in RAID-0?

    - by jasondavis
    I am wanting to replace my Operating sytem hard drive with 2 SSD drives. Well possibly just 1 but I am curious about doing 2 in a RAID-0 setup for even more improved speed. What exactly would I need to run 2 SSD drives in a raid0 setup?

    Read the article

  • Windows 2008 server smart card security module problem

    - by chris13work
    Hi, I've got a smart card reader and a server application using it as a security module. If I run it under DOS prompt, everything is fine. The server is running and clients can connect to it. I tried to install the server as window service and start it. The server starts but always gives back authentication error because it cannot call the smart card to do encryption. Then I tried to start it with task scheduler and set the trigger factor as "on startup". The server starts also but still cannot access the smart card reader. Then I tried remote desktop to the machine and run the server application under DOS prompt. Same error is returned. The situation is that the smart card reader only works under active console desktop environment. In the server application, WINSCARD API is used to access the smart card reader. Any suggestion so that we can access the smart card reader in running services? OS: Windows Server 2008 Smart Card Driver: Windows USB smart card Reader Smart Card API: WINSCARD

    Read the article

  • Windows 2008 server smart card security module problem

    - by chris13work
    Hi, I've got a smart card reader and a server application using it as a security module. If I run it under DOS prompt, everything is fine. The server is running and clients can connect to it. I tried to install the server as window service and start it. The server starts but always gives back authentication error because it cannot call the smart card to do encryption. Then I tried to start it with task scheduler and set the trigger factor as "on startup". The server starts also but still cannot access the smart card reader. Then I tried remote desktop to the machine and run the server application under DOS prompt. Same error is returned. The situation is that the smart card reader only works under active console desktop environment. In the server application, WINSCARD API is used to access the smart card reader. Any suggestion so that we can access the smart card reader in running services? OS: Windows Server 2008 Smart Card Driver: Windows USB smart card Reader Smart Card API: WINSCARD

    Read the article

< Previous Page | 31 32 33 34 35 36 37 38 39 40 41 42  | Next Page >