Search Results

Search found 27248 results on 1090 pages for 'table adapter'.

Page 35/1090 | < Previous Page | 31 32 33 34 35 36 37 38 39 40 41 42  | Next Page >

  • How to use CLEAR USB WiMax in Ubuntu (host) and Windows XP (guest) using VirtualBox

    - by bithacker
    I'm trying to use CLEAR Motorola WiMax USB in Ubuntu as there is no support for Linux as yet. I've installed Windows XP as guest in Ubuntu and the version I'm using is 3.2.2. USB is connecting fine in Windows XP but I can't use internet in Ubuntu. Can you please tell me how to do it. Here is the configuration that could help you guys. Thanks in advance. I'm using Two Network Adapters. Network Adapter 1: PCnet-FAST III (NAT) Adapter 2: PCnet-FAST III (Host-only adapter, 'vboxnet0') ipconfig [on Guest windowsXP] Windows IP Configuration Ethernet adapter Local Area Connection: PCnet-FAST III (NAT) Connection-specific DNS Suffix . : IP Address. . . . . . . . . . . . : 10.0.2.15 Subnet Mask . . . . . . . . . . . : 255.255.255.0 Default Gateway . . . . . . . . . : 10.0.2.2 Ethernet adapter Local Area Connection 3: PCnet-FAST III (Host-only adapter, 'vboxnet0') Connection-specific DNS Suffix . : IP Address. . . . . . . . . . . . : 192.168.56.101 Subnet Mask . . . . . . . . . . . : 255.255.255.0 Default Gateway . . . . . . . . . : Ethernet adapter Local Area Connection 2: Connection-specific DNS Suffix . : CLEAR Motorola USB IP Address. . . . . . . . . . . . : 10.168.242.33 Subnet Mask . . . . . . . . . . . : 255.255.192.0 Default Gateway . . . . . . . . . : 10.168.192.2 IFCONFIG [on Host Ubuntu] (Ethernet) eth0 Link encap:Ethernet HWaddr 00:14:22:b9:9d:76 UP BROADCAST MULTICAST MTU:1500 Metric:1 RX packets:0 errors:0 dropped:0 overruns:0 frame:0 TX packets:0 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:1000 RX bytes:0 (0.0 B) TX bytes:0 (0.0 B) Interrupt:16 eth1 (Wireless) Link encap:Ethernet HWaddr 00:13:ce:f0:9b:0d inet6 addr: fe80::213:ceff:fef0:9b0d/64 Scope:Link UP BROADCAST MULTICAST MTU:1500 Metric:1 RX packets:0 errors:0 dropped:0 overruns:0 frame:0 TX packets:1 errors:0 dropped:5 overruns:0 carrier:0 collisions:0 txqueuelen:1000 RX bytes:0 (0.0 B) TX bytes:84 (84.0 B) Interrupt:17 Base address:0xe000 Memory:dfcff000-dfcfffff lo Link encap:Local Loopback inet addr:127.0.0.1 Mask:255.0.0.0 inet6 addr: ::1/128 Scope:Host UP LOOPBACK RUNNING MTU:16436 Metric:1 RX packets:2292 errors:0 dropped:0 overruns:0 frame:0 TX packets:2292 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:0 RX bytes:171952 (171.9 KB) TX bytes:171952 (171.9 KB) vboxnet0 Link encap:Ethernet HWaddr 0a:00:27:00:00:00 inet addr:192.168.56.1 Bcast:192.168.56.255 Mask:255.255.255.0 inet6 addr: fe80::800:27ff:fe00:0/64 Scope:Link UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1 RX packets:0 errors:0 dropped:0 overruns:0 frame:0 TX packets:137 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:1000 RX bytes:0 (0.0 B) TX bytes:21174 (21.1 KB)

    Read the article

  • Windows Wireless Drivers - Install

    - by Justin Y.
    I have nearly ended my journey of making a dual-boot windows xp and ubuntu computer. Along with version 12.04, came the problem with my NetGear WNDA3100v2 wireless adapter. It wasn't compatible. My last step in my adventure is to install the software called Windows Wireless Drivers. I have internet access on my laptop and a flash drive. It would be preferable to receive a link to this program, because I see no link on the website, and I can't download it from the Ubuntu Software Center. Thanks.

    Read the article

  • how to update child records when updating the Master table using Linq [closed]

    - by user20358
    I currently use a general repositry class that can update only a single table like so public abstract class MyRepository<T> : IRepository<T> where T : class { protected IObjectSet<T> _objectSet; protected ObjectContext _context; public MyRepository(ObjectContext Context) { _objectSet = Context.CreateObjectSet<T>(); _context = Context; } public IQueryable<T> GetAll() { return _objectSet.AsQueryable(); } public IQueryable<T> Find(Expression<Func<T, bool>> filter) { return _objectSet.Where(filter); } public void Add(T entity) { _objectSet.AddObject(entity); _context.ObjectStateManager.ChangeObjectState(entity, System.Data.EntityState.Added); _context.SaveChanges(); } public void Update(T entity) { _context.ObjectStateManager.ChangeObjectState(entity, System.Data.EntityState.Modified); _context.SaveChanges(); } public void Delete(T entity) { _objectSet.Attach(entity); _context.ObjectStateManager.ChangeObjectState(entity, System.Data.EntityState.Deleted); _objectSet.DeleteObject(entity); _context.SaveChanges(); } } For every table class generated by my EDMX designer I create another class like this public class CustomerRepo : MyRepository<Customer> { public CustomerRepo (ObjectContext context) : base(context) { } } for any updates that I need to make to a particular table I do this: Customer CustomerObj = new Customer(); CustomerObj.Prop1 = ... CustomerObj.Prop2 = ... CustomerObj.Prop3 = ... CustomerRepo.Update(CustomerObj); This works perfectly well when I am updating just to the specific table called Customer. Now if I need to also update each row of another table which is a child of Customer called Orders what changes do I need to make to the class MyRepository. Orders table will have multiple records for a Customer record and multiple fields too, say for example Field1, Field2, Field3. So my questions are: 1.) If I only need to update Field1 of the Orders table for some rows based on a condition and Field2 for some other rows based on a different condition then what changes I need to do? 2.) If there is no such condition and all child rows need to be updated with the same value for all rows then what changes do I need to do? Thanks for taking the time. Look forward to your inputs...

    Read the article

  • Getting a Temporary Table Returned from from Dynamic SQL in SQL Server 05, and parsing

    - by gloomy.penguin
    So I was requested to make a few things.... (it is Monday morning and for some reason this whole thing is turning out to be really hard for me to explain so I am just going to try and post a lot of my code; sorry) First, I needed a table: CREATE TABLE TICKET_INFORMATION ( TICKET_INFO_ID INT IDENTITY(1,1) NOT NULL, TICKET_TYPE INT, TARGET_ID INT, TARGET_NAME VARCHAR(100), INFORMATION VARCHAR(MAX), TIME_STAMP DATETIME DEFAULT GETUTCDATE() ) -- insert this row for testing... INSERT INTO TICKET_INFORMATION (TICKET_TYPE, TARGET_ID, TARGET_NAME, INFORMATION) VALUES (1,1,'RT_ID','IF_ID,int=1&IF_ID,int=2&OTHER,varchar(10)=val,ue3&OTHER,varchar(10)=val,ue4') The Information column holds data that needs to be parsed into a table. This is where I am having problems. In the resulting table, Target_Name needs to become a column that holds Target_ID as a value for each row in the resulting table. The string that needs to be parsed is in this format: @var_name1,@var_datatype1=@var_value1&@var_name2,@var_datatype2=@var_value2&@var_name3,@var_datatype3=@var_value3 And what I ultimately need as a result (in a table or table variable): RT_ID IF_ID OTHER 1 1 val,ue3 1 2 val,ue3 1 1 val,ue4 1 2 val,ue4 And I need to be able to join on the result. Initially, I was just going to make this a function that returns a table variable but for some reason I can't figure out how to get it into an actual table variable. Whatever parses the string needs to be able to be used directly in queries so I don't think a stored procedure is really the right thing to be using. This is the code that parses the Information string... it returns in a temporary table. -- create/empty temp table for var_name, var_type and var_value fields if OBJECT_ID('tempdb..#temp') is not null drop table #temp create table #temp (row int identity(1,1), var_name varchar(max), var_type varchar(30), var_value varchar(max)) -- just setting stuff up declare @target_name varchar(max), @target_id varchar(max), @info varchar(max) set @target_name = (select target_name from ticket_information where ticket_info_id = 1) set @target_id = (select target_id from ticket_information where ticket_info_id = 1) set @info = (select information from ticket_information where ticket_info_id = 1) --print @info -- some of these variables are re-used later declare @col_type varchar(20), @query varchar(max), @select as varchar(max) set @query = 'select ' + @target_id + ' as ' + @target_name + ' into #target; ' set @select = 'select * into ##global_temp from #target' declare @var_name varchar(100), @var_type varchar(100), @var_value varchar(100) declare @comma_pos int, @equal_pos int, @amp_pos int set @comma_pos = 1 set @equal_pos = 1 set @amp_pos = 0 -- while loop to parse the string into a table while @amp_pos < len(@info) begin -- get new comma position set @comma_pos = charindex(',',@info,@amp_pos+1) -- get new equal position set @equal_pos = charindex('=',@info,@amp_pos+1) -- set stuff that is going into the table set @var_name = substring(@info,@amp_pos+1,@comma_pos-@amp_pos-1) set @var_type = substring(@info,@comma_pos+1,@equal_pos-@comma_pos-1) -- get new ampersand position set @amp_pos = charindex('&',@info,@amp_pos+1) if @amp_pos=0 or @amp_pos<@equal_pos set @amp_pos = len(@info)+1 -- set last variable for insert into table set @var_value = substring(@info,@equal_pos+1,@amp_pos-@equal_pos-1) -- put stuff into the temp table insert into #temp (var_name, var_type, var_value) values (@var_name, @var_type, @var_value) -- is this a new field? if ((select count(*) from #temp where var_name = (@var_name)) = 1) begin set @query = @query + ' create table #' + @var_name + '_temp (' + @var_name + ' ' + @var_type + '); ' set @select = @select + ', #' + @var_name + '_temp ' end set @query = @query + ' insert into #' + @var_name + '_temp values (''' + @var_value + '''); ' end if OBJECT_ID('tempdb..##global_temp') is not null drop table ##global_temp exec (@query + @select) --select @query --select @select select * from ##global_temp Okay. So, the result I want and need is now in ##global_temp. How do I put all of that into something that can be returned from a function (or something)? Or can I get something more useful returned from the exec statement? In the end, the results of the parsed string need to be in a table that can be joined on and used... Ideally this would have been a view but I guess it can't with all the processing that needs to be done on that information string. Ideas? Thanks!

    Read the article

  • LaTeX table too wide. How to make it fit?

    - by Erik B
    I just started to learn latex and now I'm trying to create a table. This is my code: \begin{table} \caption{Top Scorers} \begin{tabular}{ l l } \hline \bf Goals & \bf Players\\ \hline 4 & First Last, First Last, First Last, First Last\\ 3 & First Last\\ 2 & First Last\\ 1 & First Last, First Last, First Last, First Last, First Last, First Last, First Last, First Last, First Last, First Last, First Last, First Last, First Last\\ \hline \end{tabular} \end{table} The problem is that the table is wider than the page. I was hoping that it would automatically fit to the page like normal text does, but it didn't. How do I tell latex to make the table fit to the page?

    Read the article

  • How to make a table, which is wider than screen size, scrollable?

    - by understack
    I've a table with 2 columns and each column is 800px wide. I want to show this table in 800x50 window. So there should be horizontal and vertical scrollbar to view complete table. While I've found few related solutions (this and this) on SO, they only work if table width is smaller than screen size. In my case screen size is 1200px and total table width is 1600px. How could I do this? i want to achieve something like this.

    Read the article

  • How to make last line of each table's part unfinished in latex longtable?

    - by diver_ru
    I have a table that automatically stretched over several pages by longtable package. \begin{longtable}{| l | l |} \hline A & B \\ \hline \endfirsthead \multicolumn{3}{l}{Table \thetable{} -- finishing} \\ \hline \endhead a1 & b1 \\ \hline a1 & b2 \\ hline ........ \end{longtable} Suppose that table broken (automatically) between first and second lines. Now i have this: ------- |A | B| ------- |a1|b1| ------- <page break> Table 1 -- finishing. ------- |a2|b2| ------- I want the following effect: ------- |A | B| ------- |a1|b1| <page break> Table 1 -- finishing. ------- |a2|b2| ------- I.e. last line of broken part should be unfinished.

    Read the article

  • Daemon Tools Lite Error- Unable to add adapter

    - by Lirik
    I just got a ThinkPad T510 with Windows 7 Professional and I installed Daemon Tools Lite, but I keep getting an error when I run it: Unable to add adapter. I tried starting it as an administrator, but I got the same problem. Does anybody know how to fix this?

    Read the article

  • Too many Tunnel Adapter Interfaces

    - by Tomas Lycken
    If I open a command prompt on my machine and type ipconfig /all, I see lots of Tunnel adapter Local Area Connection* 9: Media state . . . . . . . . . . . . . : Media disconnected Connection-specific DNS Sufficx . . . : Description . . . . . . . . . . . . . : Microsoft 6to4 Adapter #5 Physical address. . . . . . . . . . . : 00-00-00-00-00-00-00-E0 DHCP Enabled. . . . . . . . . . . . . : No Autoconfiguration Enabled . . . . . . : Yes In fact, they're so many that my "real" adapters are pushed out of the stack, and can't be seen anymore. Is there any flag I can use on ipconfig to hide all virtual interfaces? Or is there some other way around this problem? Since they always say "Media disconnected" I suppose disabling could be an option, but if possible I'd rather not turn any functionality off. I just want to control what output I get from ipconfig. Also, I know these are related to IPv6 stuff. However, most of what I find on google merely states what these are, and that they're harmless - nothing about hiding/removing them.

    Read the article

  • Ubuntu doesn't detect drives conected to LSI "Host Bus Adapter"

    - by dvrecmfo
    I purchased LSI SAS 9300-4i Host Bus Adapter, from card bios I can see that it detected all hard drives connected to it, but from ubuntu I can't see them. What I've tried: Installed the driver provided here http://www.lsi.com/products/host-bus-adapters/pages/lsi-sas-9300-4i.aspx#tab/tab3 (I tried both LINUX_RH_SL_OEL_CTX_MPT_GEN3_C0_Phase2.0-3.00.00.00-1 and Linux_Driver_RHEL5-6_SLES10-11_P1) lspci | grep -i lsi 07:00.0 Serial Attached SCSI controller: LSI Logic / Symbios Logic SAS3004 PCI-Express Fusion-MPT SAS-3 (rev 02)

    Read the article

  • wireless ethernet adapter with EAP-PEAP?

    - by Joseph
    We have a wireless network set up to support WPA or WPA2 with AES or TKIP encryption and EAP-PEAP authentication. Users are wanting to connect devices that don't have the ability to do EAP-PEAP but have ethernet ports. I have found a wireless printer server that can do this, but I have yet to find a wireless ethernet adapter that can. Has anyone seen one with this ability?

    Read the article

  • USB TO DB9 Adapter

    - by Ioudas
    I have a USB-to-DB9 adapter, no FCC serial visible anywhere, that I need drivers for. I can't seem to get any relevant info searching on Google. Does anyone have any good ideas where I might be able to get a lead on some drivers? I'll even upload a picture of it.

    Read the article

  • Too many Tunnel Adapter Interfaces

    - by Tomas Lycken
    If I open a command prompt on my machine and type ipconfig /all, I see lots of Tunnel adapter Local Area Connection* 9: Media state . . . . . . . . . . . . . : Media disconnected Connection-specific DNS Sufficx . . . : Description . . . . . . . . . . . . . : Microsoft 6to4 Adapter #5 Physical address. . . . . . . . . . . : 00-00-00-00-00-00-00-E0 DHCP Enabled. . . . . . . . . . . . . : No Autoconfiguration Enabled . . . . . . : Yes In fact, they're so many that my "real" adapters are pushed out of the stack, and can't be seen anymore. Is there any flag I can use on ipconfig to hide all virtual interfaces? Or is there some other way around this problem? Since they always say "Media disconnected" I suppose disabling could be an option, but if possible I'd rather not turn any functionality off. I just want to control what output I get from ipconfig. Also, I know these are related to IPv6 stuff. However, most of what I find on google merely states what these are, and that they're harmless - nothing about hiding/removing them.

    Read the article

  • How to turn off ATI adapter on Acer Timeline 4810G with ubuntu 9.10

    - by netimen
    I can't turn off my ATI adapter. I have applied the fix, but still lspci | grep VGA gives 00:02.0 VGA compatible controller: Intel Corporation Mobile 4 Series Chipset Integrated Graphics Controller (rev 07) 01:00.0 VGA compatible controller: ATI Technologies Inc M92 LP [Mobility Radeon HD 4300 Series] (rev ff) and my power consumption is about 15W (Wi-Fi on). I run ubuntu 9.10, kernel 2.6.31-14-generic. BIOS version 2.30

    Read the article

  • USB Wireless adapter that works with Windows 7 (32 and 64bit)

    - by Kjensen
    Can anybody recommend a USB wireless network adapter, that has Windows 7 drivers for both 32 and 64 bit? It also needs to reconnect to the network when the computer is brought out of sleep. I have three of these from earlier (from Allnet, trendnet and linksys), and just one of them has working drivers for Win7 64bit - but fail to return from sleep in a working state.

    Read the article

  • What's the best-practice way to update an Adapter's underlying data?

    - by skyler
    I'm running into an IllegalStateException updating an underlying List to an Adapter (might be an ArrayAdapter or an extension of BaseAdapter, I don't remember). I do not have or remember the text of the exception at the moment, but it says something to the effect of the List's content changing without the Adapter having been notified of the change. This List /may/ be updated from another thread other than the UI thread (main). After I update this list (adding an item), I call notifyDataSetChanged. The issue seems to be that the Adapter, or ListView attached to the Adapter attempts to update itself before this method is invoked. When this happens, the IllegalStateException is thrown. If I set the ListView's visibility to GONE before the update, then VISIBLE again, no error occurs. But this isn't always practical. I read somewhere that you cannot modify the underlying this from another thread--this would seem to limit an MVC pattern, as with this particular List, I want to add items from different threads. I assumed that as long as I called notifyDataSetChanged() I'd be safe--that the Adapter didn't revisit the underlying List until this method was invoked but this doesn't seem to be the case. I suppose what I'm asking is, can it be safe to update the underlying List from threads other than the UI? Additionally, if I want to modify the data within an Adapter, do I modify the underlying List or the Adapter itself (via its add(), etc. methods). Modifying the data through the Adapter seems wrong. I came across a thread on another site from someone who seems to be having a similar problem to mine: http://osdir.com/ml/Android-Developers/2010-04/msg01199.html (this is from where I grabbed the Visibility.GONE and .VISIBLE idea). To give you a better idea of my particular problem, I'll describe a bit of how my List, Adapter, etc. are set up. I've an object named Queue that contains a LinkedList. Queue extends Observable, and when things are added to its internal list through its methods, I call setChanged() and notifyListeners(). This Queue object can have items added or removed from any number of threads. I have a single "queue view" Activity that contains an Adapter. This Activity, in its onCreate() method, registers an Observer listener to my Queue object. In the Observer's update() method I call notifyDataSetChanged() on the Adapter. I added a lot of log output and determined that when this IllegalStateExcption occurs that my Observer callback was never invoked. So it's as if the Adapter noticed the List's change before the Observer had a chance to notify its Observers, and call my method to notify the Adapter that the contents had changed. So I suppose what I'm asking is, is this a good way to rig-up an Adapter? Is this a problem because I'm updating the Adapter's contents from a thread other than the UI thread? If this is the case, I may have a solution in mind (give the Queue object a Handler to the UI thread when it's created, and make all List modifications using that Handler, but this seems improper). I realize that this is a very open-ended post, but I'm a bit lost on this and would appreciate any comments on what I've written.

    Read the article

  • $.fadeTo/fadeOut() operations on Table Rows in IE fail

    - by Rick Strahl
    Here’s a a small problem that one of customers ran into a few days ago: He was playing around with some of the sample code I’ve put out for one of my simple jQuery demos which deals with providing a simple pulse behavior plug-in: $.fn.pulse = function(time) { if (!time) time = 2000; // *** this == jQuery object that contains selections $(this).fadeTo(time, 0.20, function() { $(this).fadeTo(time, 1); }); return this; } it’s a very simplistic plug-in and it works fine for simple pulse animations. However he ran into a problem where it didn’t work when working with tables – specifically pulsing a table row in Internet Explorer. Works fine in FireFox and Chrome, but IE not so much. It also works just fine in IE as long as you don’t try it on tables or table rows specifically. Applying against something like this (an ASP.NET GridView): var sel = $("#gdEntries>tbody>tr") .not(":first-child") // no header .not(":last-child") // no footer .filter(":even") .addClass("gridalternate"); // *** Demonstrate simple plugin sel.pulse(2000); fails in IE. No pulsing happens in any version of IE. After some additional experimentation with single rows and various ways of selecting each and still failing, I’ve come to the conclusion that the various fade operations in jQuery simply won’t work correctly in IE (any version). So even something as ‘elemental’ as this: var el = $("#gdEntries>tbody>tr").get(0);$(el).fadeOut(2000); is not working correctly. The item will stick around for 2 seconds and then magically disappear. Likewise: sel.hide().fadeIn(5000); also doesn’t fade in although the items become immediately visible in IE. Go figure that behavior out. Thanks to a tweet from red_square and a link he provided here is a grid that explains what works and doesn’t in IE (and most last gen browsers) regarding opacity: http://www.quirksmode.org/js/opacity.html It appears from this link that table and row elements can’t be made opaque, but td elements can. This means for the row selections I can force each of the td elements to be selected and then pulse all of those. Once you have the rows it’s easy to explicitly select all the columns in those rows with .find(“td”). Aha the following actually works: var sel = $("#gdEntries>tbody>tr") .not(":first-child") // no header .not(":last-child") // no footer .filter(":even") .addClass("gridalternate"); // *** Demonstrate simple plugin sel.find("td").pulse(2000); A little unintuitive that, but it works. Stay away from <table> and <tr> Fades The moral of the story is – stay away from TR, TH and TABLE fades and opacity. If you have to do it on tables use the columns instead and if necessary use .find(“td”) on your row(s) selector to grab all the columns. I’ve been surprised by this uhm relevation, since I use fadeOut in almost every one of my applications for deletion of items and row deletions from grids are not uncommon especially in older apps. But it turns out that fadeOut actually works in terms of behavior: It removes the item when the timeout’s done and because the fade is relatively short lived and I don’t extensively test IE code any more I just never noticed that the fade wasn’t happening. Note – this behavior or rather lack thereof appears to be specific to table table,tr,th elements. I see no problems with other elements like <div> and <li> items. Chalk this one up to another of IE’s shortcomings. Incidentally I’m not the only one who has failed to address this in my simplistic plug-in: The jquery-ui pulsate effect also fails on the table rows in the same way. sel.effect("pulsate", { times: 3 }, 2000); and it also works with the same workaround. If you’re already using jquery-ui definitely use this version of the plugin which provides a few more options… Bottom line: be careful with table based fade operations and remember that if you do need to fade – fade on columns.© Rick Strahl, West Wind Technologies, 2005-2010Posted in jQuery  

    Read the article

  • iTextSharp - Bug in the table functions?

    - by Matthias
    Hello all together, I try to make a table like this: PdfPTable Table = new PdfPTable(6); PdfPCell Cell = new PdfPCell(new Phrase("a", Font1)); Cell.Rowspan = 2; Cell.Colspan = 2; Table.AddCell(Cell); Cell = new PdfPCell(new Phrase("b", Font1)); Cell.Rowspan = 2; Cell.Colspan = 2; Table.AddCell(Cell); Cell = new PdfPCell(new Phrase("c", Font1)); Cell.Colspan = 2; Table.AddCell(Cell); Cell = new PdfPCell(new Phrase("d", Font1)); Cell.Colspan = 2; Table.AddCell(Cell); That works fine. But changing the number of columns will destory the table. Is it a bug or do I make something wrong? This code destroys the table: PdfPTable Table = new PdfPTable(17); PdfPCell Cell = new PdfPCell(new Phrase("a", Font1)); Cell.Rowspan = 2; Cell.Colspan = 2; Table.AddCell(Cell); Cell = new PdfPCell(new Phrase("b", Font1)); Cell.Rowspan = 2; Cell.Colspan = 10; Table.AddCell(Cell); Cell = new PdfPCell(new Phrase("c", Font1)); Cell.Colspan = 5; Table.AddCell(Cell); Cell = new PdfPCell(new Phrase("d", Font1)); Cell.Colspan = 5; Table.AddCell(Cell); Edit: The table should have this layout: |-------------------------------------------------------| | Cell "a" with | Cell "b" with | Cell "c", colspan = 5 | | colspan = 2 | colspan = 10 |-----------------------| | rowspan = 2 | rowspan = 2 | Cell "d", colspan = 5 | |-------------------------------------------------------| Best regards, Matthias

    Read the article

  • Programmatically retrieve disconnected network adapter information in .NET

    - by Soo Wei Tan
    I have an application written in C# that needs to retrieve information like IP address, subnet mask from a disconnected network adapter. I've tried using various methods such as WMI and the .NET NetworkAdapter class but they don't return any useful data when the network adapter is disconnected. I'm pretty sure Windows keeps this information somewhere, since I can apply network settings using netsh and it appears correctly in the Control Panel. One thing that worked for me in XP was to parse the output of the netsh tool and it would return information even for a disconnected adapter. However, this doesn't seem to work on Windows 7. Win XP output: Configuration for interface "Local Area Connection 5" DHCP enabled: No IP Address: 169.254.0.128 SubnetMask: 255.255.255.0 InterfaceMetric: 0 Win7 output: Configuration for interface "Local Area Connection 2" DHCP enabled: No InterfaceMetric: 5 Any ideas?

    Read the article

  • Activerecord-PostgreSQL Adapter Error

    - by Tian
    When running "rake db:migrate", i receive the following error: Please install the postgresql adapter: gem install activerecord-postgresql-adapter (dlopen(/Library/Ruby/Gems/1.8/gems/pg-0.9.0/lib/pg_ext.bundle, 9): no suitable image found. Did find: /Library/Ruby/Gems/1.8/gems/pg-0.9.0/lib/pg_ext.bundle: mach-o, but wrong architecture - /Library/Ruby/Gems/1.8/gems/pg-0.9.0/lib/pg_ext.bundle) Postgres 8.4.4 installed using the pre-built image file. Then ran sudo gem install pg to install pg-0.9.0 Config/database.yml: development: adapter: postgresql Does anyone know what the problem is?

    Read the article

  • Two n x m relationships with the same table in mysql

    - by Christian
    I want to create a database in which there's an n x m relationship between the table drug and the table article and an n x m relationship between the table target and the table article. I get the error: Cannot delete or update a parent row: a foreign key constraint fails What do I have to change in my code? DROP TABLE IF EXISTS `textmine`.`article`; CREATE TABLE `textmine`.`article` ( `id` int(10) unsigned NOT NULL AUTO_INCREMENT COMMENT 'Pubmed ID', `abstract` blob NOT NULL, `authors` blob NOT NULL, `journal` varchar(256) CHARACTER SET utf8 COLLATE utf8_bin NOT NULL, PRIMARY KEY (`id`) ) ENGINE=InnoDB DEFAULT CHARSET=utf8; DROP TABLE IF EXISTS `textmine`.`drugs`; CREATE TABLE `textmine`.`drugs` ( `id` int(10) unsigned NOT NULL COMMENT 'This ID is taken from the biosemantics dictionary', `primaryName` varchar(256) CHARACTER SET utf8 COLLATE utf8_bin NOT NULL, PRIMARY KEY (`id`) ) ENGINE=InnoDB DEFAULT CHARSET=utf8; DROP TABLE IF EXISTS `textmine`.`targets`; CREATE TABLE `textmine`.`targets` ( `id` int(10) unsigned NOT NULL AUTO_INCREMENT, `primaryName` varchar(256) CHARACTER SET utf8 COLLATE utf8_bin NOT NULL, PRIMARY KEY (`id`) ) ENGINE=InnoDB DEFAULT CHARSET=utf8; DROP TABLE IF EXISTS `textmine`.`containstarget`; CREATE TABLE `textmine`.`containstarget` ( `targetid` int(10) unsigned NOT NULL, `articleid` int(10) unsigned NOT NULL, KEY `target` (`targetid`), KEY `article` (`articleid`), CONSTRAINT `article` FOREIGN KEY (`articleid`) REFERENCES `article` (`id`), CONSTRAINT `target` FOREIGN KEY (`targetid`) REFERENCES `targets` (`id`) ) ENGINE=InnoDB DEFAULT CHARSET=utf8; DROP TABLE IF EXISTS `textmine`.`contiansdrug`; CREATE TABLE `textmine`.`contiansdrug` ( `drugid` int(10) unsigned NOT NULL, `articleid` int(10) unsigned NOT NULL, KEY `drug` (`drugid`), KEY `article` (`articleid`), CONSTRAINT `article` FOREIGN KEY (`articleid`) REFERENCES `article` (`id`), CONSTRAINT `drug` FOREIGN KEY (`drugid`) REFERENCES `drugs` (`id`) ) ENGINE=InnoDB DEFAULT CHARSET=utf8;

    Read the article

< Previous Page | 31 32 33 34 35 36 37 38 39 40 41 42  | Next Page >