Search Results

Search found 6942 results on 278 pages for 'enabled'.

Page 36/278 | < Previous Page | 32 33 34 35 36 37 38 39 40 41 42 43  | Next Page >

  • Show WPF tooltip on disabled item only

    - by DT
    Just wondering if it is possible to show a WPF on a disabled item ONLY (and not when the item is enabled). I would like to give the user a tooltip explaining why an item is currently disabled. I have an IValueConverter to invert the boolean IsEnabled property binding. But it doesn't seem to work in this situation. The tooltip is show both when the item is enabled and disabled. So is is possible to bind a tooltip.IsEnabled property exclusively to an item's own !IsEnabled? Pretty straightforward question I guess, but code example here anyway: public class BoolToOppositeBoolConverter : IValueConverter { #region IValueConverter Members public object Convert(object value, Type targetType, object parameter, System.Globalization.CultureInfo culture) { if (targetType != typeof(bool)) throw new InvalidOperationException("The target must be a boolean"); return !(bool)value; } public object ConvertBack(object value, Type targetType, object parameter, System.Globalization.CultureInfo culture) { if (targetType != typeof(bool)) throw new InvalidOperationException("The target must be a boolean"); return !(bool)value; } #endregion } And the binding: <TabItem Header="Tab 2" Name="tabItem2" ToolTip="Not enabled in this situation." ToolTipService.ShowOnDisabled="True" ToolTipService.IsEnabled="{Binding Path=IsEnabled, ElementName=tabItem2, Converter={StaticResource oppositeConverter}}"> <Label Content="Item content goes here" /> </TabItem> Thanks folks.

    Read the article

  • C# StripStatusText Update Issue

    - by ikurtz
    I am here due to a strange behaviour in Button_Click event. The code is attached. The issue is the first StripStatus message is never displayed. any ideas as to why? private void FireBtn_Click(object sender, EventArgs e) { // Control local controls for launching attack AwayTableLayoutPanel.Enabled = false; AwayCancelBtn.Enabled = false; FireBtn.Enabled = false; ////////////// Below statusBar message is never displayed but the folowing sound clip is. GameToolStripStatusLabel.Text = "(Home vs. Away)(Attack Coordinate: (" + GameModel.alphaCoords(GridLock.Column) + "," + GridLock.Row + "))(Action: Fire)"; //////////////////////////////////////////// if (audio) { SoundPlayer fire = new SoundPlayer(Properties.Resources.fire); fire.PlaySync(); fire.Dispose(); } // compile attack message XmlSerializer s; StringWriter w; FireGridUnit fireGridUnit = new FireGridUnit(); fireGridUnit.FireGridLocation = GridLock; s = new XmlSerializer(typeof(FireGridUnit)); w = new StringWriter(); s.Serialize(w, fireGridUnit); ////////////////////////////////////////////////////////// // send attack message GameMessage GameMessageAction = new GameMessage(); GameMessageAction.gameAction = GameMessage.GameAction.FireAttack; GameMessageAction.statusMessage = w.ToString(); s = new XmlSerializer(typeof(GameMessage)); w = new StringWriter(); s.Serialize(w, GameMessageAction); SendGameMsg(w.ToString()); GameToolStripStatusLabel.Text = "(Home vs. Away)(Attack Coordinate: (" + GameModel.alphaCoords(GridLock.Column) + "," + GridLock.Row + "))(Action: Awaiting Fire Result)"; } EDIT: if I put in a messageBox after the StripStatus message the status is updated.

    Read the article

  • Session expiry times?

    - by user246114
    Hi, I've enabled sessions on my app: // appengine-web.xml <sessions-enabled>true</sessions-enabled> they seem to work when I load different pages under my domain. If I close the browser however, looks like the session is terminated. Restarting the browser shows the last session is no longer available. That could be fine, just wondering if this is documented anywhere, so I can rely on this fact? I tried the following just to test if we can tweak it: // in web.xml <session-config> <session-timeout>10</session-timeout> </session-config> also // in my servlet getThreadLocalRequest().getSession().setMaxInactiveInterval(60 * 5); but same behavior, session data is no longer available after browser restart. I looked at the stats for my project and I see data being used for something like "_ah_SESSION" objects. Are those the sessions from above? If so, shouldn't they be cleaned since they're no longer valid? (Hopefully gae takes care of that automatically?) Thanks

    Read the article

  • Combining properties made available via webservices profile service aspnet

    - by Adam
    I really wasn't sure what the title for my question could be, so sorry if it's a bit vague. I'm working on an application that uses client application services for authentication/profile management etc. In web.config for my website, I have the following profile properties like this: <properties> <add name="FirstName" type="string" defaultValue="" customProviderData="FirstName;nvarchar"/> ... Basic things like first name, last name etc. I'm exposing properties for my client app like this: <system.web.extensions> <scripting> <webServices> <authenticationService enabled="true" requireSSL="false"/> <profileService enabled="true" readAccessProperties="UserProfile" writeAccessProperties="UserProfile"/> <roleService enabled="true"/> </webServices> </scripting> </system.web.extensions> What I'm wondering is whether it's possible to bundle all the individual profile properties into a single object for client apps to utilize? I originally had all my profile data stored as members of a single class (UserProfile) but I broke it all out so that I could use the SqlTableProfileProvider to store each field as individual columns in relevant tables. I know I can create an class with members for each type, I'm just not sure if there's an easy way to create an object with all my property values (other than assigning values to this object whenever I assign to the the standalone properties). I don't think I'm explaining this very well, so I'll try an example. Say in my website profile I have FirstName and LastName as properties. For my client application profileService I want to have one ReadAccessProperty FullName. Is there some way to automatically create FullName from the existing FirstName and LastName properties without having to also have a seperate FullName property (and manually assign data to it whenever I assign data to FirstName and LastName)?

    Read the article

  • Optional Member Objects

    - by David Relihan
    Okay, so you have a load of methods sprinkled around your systems main class. So you do the right thing and refactor by creating a new class and perform move method(s) into a new class. The new class has a single responsibility and all is right with the world again: class Feature { public: Feature(){}; void doSomething(); void doSomething1(); void doSomething2(); }; So now your original class has a member variable of type object: Feature _feature; Which you will call in the main class. Now if you do this many times, you will have many member-objects in your main class. Now these features may or not be required based on configuration so in a way it's costly having all these objects that may or not be needed. Can anyone suggest a way of improving this? At the moment I plan to test in the newly created class if the feature is enabled - so the when a call is made to method I will return if it is not enabled. I could have a pointer to the object and then only call new if feature is enabled - but this means I will have to test before I call a method on it which would be potentially dangerous and not very readable. Would having an auto_ptr to the object improve things: auto_ptr<Feature> feature; Or am I still paying the cost of object invokation even though the object may\or may not be required. BTW - I don't think this is premeature optimisation - I just want to consider the possibilites.

    Read the article

  • How to Read Device Data From serial port

    - by Aamir Khurshid
    I have one device which sends data on COM port say on COM13. Now i want to read that data and display it in the RichTextBox or in any text control. I have written the application with the help of IO and IO.Ports but comport.DataRecived event does not fire, even though device is sending data on that port. I have some software on which i define the port number and it successfully display data, which insure me that data is receiving on the Port but i am unable to receive. Is there any way i can read data? comm.Parity = cboParity.Text;//None comm.StopBits = cboStop.Text;//One comm.DataBits = cboData.Text;//8 comm.BaudRate = cboBaud.Text;//9600 comm.DisplayWindow = rtbDisplay;//Null comm.PortName = "COM13"; comm.OpenPort(); cmdOpen.Enabled = false; cmdClose.Enabled = true; cmdSend.Enabled = true; public bool OpenPort() { if (comPort.IsOpen) { comPort.Close(); } comPort.DataReceived += new SerialDataReceivedEventHandler(comPort_DataReceived); comPort.PortName = _portName; comPort.Open();return true; }

    Read the article

  • Should onSaveInstanceState save the "enabledness" of the views?

    - by neutrino
    Hi there, I have a preferences activity where I can change the language and the theme of my application. From there I return to the previous activity via the Back key, and I want to recreate the activity. I've managed to do that by reinitializing the layout in onResume and also calling onRestoreInstanceState from there. All the views are restored properly, with checkboxes checked if needed, edittexts filled with texts I left there previously. But I also have a button which is initially disabled, and becomes enabled only when a radiobutton is checked. The problem with it is the following: I check the radiobutton, the button becomes enabled. Then I go to settings, change the theme there, and return to the first activity. When I arrive there, the radiobutton is still checked, but the button is disabled. So it seems that the enabled/disabled state isn't being saved into the bundle, which seems counterintuitive. And I haven't found any code in the Android source that does this, too. Am I missing something, or do I have to write my own code for that?

    Read the article

  • WPF : Command routing for Keyboard shortcuts.

    - by Sprotty
    Basically I want to create a keyboard shortcut which is valid within the scope of a window, and not just enabled when focus is within the control that binds it. in more detail.... I have a window which has 3 controls a toolbar textbox Custom Control The toolbar has a button bound to the Command CustomCommands.CmdA and linked to 'Ctrl-T'. My Custom Control can process CmdA. When I run the app and click on my custom control CmdA is enabled and works fine. Also Ctrl-T cause the command to fire. However when I select the text box, my custom command CmdA becomes disabled. I can rectify this by setting the command target for CmdA's button. Now when I select the textBox, CmdA is still enabled. But the Keyboard shortcut Ctrl-T does nothing. Is there any easy way to change the scope of keyboard shortcuts? Or do I need to catch the keypress somewhere lower down, and work out which Command it relates to and route it myself (if so is there a framework within which to do this?) Many Thanks Simon

    Read the article

  • JDialog setResizable(false) is not working in Window Title Bar Menu

    - by jolonaleur
    JDialog setResizable(false) is not working in Window Title Bar Menu Windows XP SP2 Java JRE 1.6.0_11-b03 Behavior varies. Sometimes, the Maximize and Minimize item on the window menu is disabled and sometimes enabled. Steps to reproduce enabled Maximize and Minimize button: Show the JDialog with setResizable(false) Open another window, say for example Notepad. Right-click on the window title bar of Notepad and click Maximize. Go to your JDialog and right click on the window title bar. Maximize window is enabled. Likewise, to disable the Maximize item for the JDialog, go to the maximized Notepad window and right click on title bar. Maximize item is disabled in the Notepad window. Go the your JDialog and right click on the title bar, notice that the Maximize item is also disabled. Note that my application can not use the defaultLookAndFeel method of java dialogs. The bug report related to this was for Solaris OS but that was already ages ago. bug report Is there any workaround? Thanks.

    Read the article

  • SQL Server service broker reporting as off when I have written a query to turn it on

    - by dotnetdev
    I have made a small ASP.NET website. It uses sqlcachedependency The SQL Server Service Broker for the current database is not enabled, and as a result query notifications are not supported. Please enable the Service Broker for this database if you wish to use notifications. Description: An unhandled exception occurred during the execution of the current web request. Please review the stack trace for more information about the error and where it originated in the code. Exception Details: System.InvalidOperationException: The SQL Server Service Broker for the current database is not enabled, and as a result query notifications are not supported. Please enable the Service Broker for this database if you wish to use notifications. Source Error: Line 12: System.Data.SqlClient.SqlDependency.Start(connString); This is the erroneous line in my global.asax. However, in sql server (2005), I enabled service broker like so (I connect and run the SQL Server service when I debug my site): ALTER DATABASE mynewdatabase SET ENABLE_BROKER with rollback immediate And this was successful. What am I missing? I am trying to use sql caching dependency and have followed all procedures. Thanks

    Read the article

  • Dangers when deploying Flash/Flex UI test automation hooks to production?

    - by Merlyn Morgan-Graham
    I am interested in doing automated testing against a Flex based UI. I have found out that my best options for UI automation (due to being C# controllable, good licensing conditions, etc) all seem to require that I compile test hooks into my application. Because of this, I am thinking of recommending that these hooks be compiled into our build. I have found a few places on the net that recommend not deploying bits with this instrumentation enabled, and I'd like to know why. Is it a performance drain, or a security risk? If it is a security risk, can you explain how the attack surface is increased? I am not a Flash or Flex developer, though I have some experience with threat modeling. For reference, here's the tools I'm specifically considering: QTP Selenium-Flex API I am having problems finding all the warnings/suggestions I found last night, but here's an example that I can find: http://www.riatest.com/products/getting-started.html Warning! Automation enabled applications expose all properties of all GUI components. This makes them vulnerable to malicious use. Never make automation enabled application publicly available. Always restrict access to such applications and to RIATest Loader to trusted users only. Related question (how to do conditional compilation to insert/remove those hooks): Conditionally including Flex libraries (SWCs) in mxmlc/compc ant tasks

    Read the article

  • problem with implementing a simple work queue

    - by John Deerikio
    Hi all, I am having troubles with implementing a simple work queue. Doing some analysis, I am facing a subtle problem. The work queue is backed by a regular linked list. The code looks like this (simplified): 0. while (true) 1. while (enabled == true) 2. acquire lock on the list and get the next action to be executed (blocking operation) (store it in a local variable) 3. execute the action (outside the lock on the list on previous line) 4. get lock on this work queue 5. wait until this work queue has been notified (triggered when setEnabled(true) has been callled) The setEnabled(e) operation looks like this (simplified): enabled = e if (enabled == true) acquire lock on this work queue and do notify() Although this works, there is a condition in which a deadlock occurs. It happens in the following rare situation: while an action is being executed, setEnabled(false) is called just before step (4) is entered, setEnabled(true) is called now step (5) keeps waiting forever, because this work queue has already been notified How do I solve this? I have been looking at this for some time, but I cannot come up with a solution. Please note I am fairly new to thread synchronization. Thanks a lot.

    Read the article

  • Make Trac use a Drupal user database for authentication

    - by denisw
    I am trying to set up a Trac instance as a complement to a Drupal site and would like to give users the possibility to use their Drupal account in Trac, too, ideally in a single sign-on fashion (if the user is already logged into Drupal, he is automatically logged into Trac). The question now is how to accomplish this. I have found a plugin named DrupalIntegration which seems to implement that functionality; however, it is poorly documented - in fact, not documented at all. I managed to install it, but don't know how to configure it. Here is what I came up with from looking at the source code and the documentation of the AccountManager plugin (on which DrupalIntegration depends): [components] trac.web.auth.loginmodule = disabled acct_mgr.api = enabled acct_mgr.web_ui.LoginModule = enabled acct_mgr.web_ui.RegistrationModule = disabled TracDrupalIntegration.DrupalIntegration = enabled [account-manager] drupal_database = mysql://<usernam>:<password>@localhost/<db> password_store = DrupalIntegration (<username>, <password> and <db> are naturally substituted with the correct data). While the Trac log says: 2010-12-18 10:54:09,570 Trac[loader] DEBUG: Loading TracDrupalIntegration from /usr/lib/python2.5/site-packages/TracDrupalIntegration-0.1-py2.5.egg this doesn't seem to work: trying to log in with a Drupal username / password results in an "Invalid username or password" error. Has someone used the DrupalIntegration and can point out to me what I did wrong? Or is there any other approach you know (or even have used in the past) to integrate Drupal and Trac that way?

    Read the article

  • Enabling all buttons in a repeater except for the clicked one

    - by NewAmbition
    I have a Repeater Control with various buttons in it. When the button gets clicked, it needs to disable itself so it cant be clicked again. Working. However, when I click that button, it needs to enable any other button but it. So, When I click on it, it needs to disable. When I click on another one, the previous button must enable, and that one must disable. So for I've tried: Button btnLoad = (Button)e.Item.FindControl("btnLoad"); foreach (Button b in e.Item.Controls.OfType<Button>().Select(c => c).Where(b => b != btnLoad)) { b.Enabled = true; } btnLoad.Text = "Currently Viewing"; btnLoad.Enabled = false; But it isnt working. Depending on where I put it, its either leaving all the buttons enabled (But still changing its text), or not doing anything at all. What do I need to do to make this work?

    Read the article

  • checkboxes and buttons enable

    - by anshka_3033 3033
    i have 2 checkboxes and 2 buttons below the check boxes. on opening the page ,checkbox1 should be enabled and other check box n buttons should be disabled.after clicking on 1st checkbox 2nd checkbox should be enabled and 1 st check box should be disabled and buttons remain disabled.after clicking on 2nd checkbox 2 buttons(approve,Deny) should be enabled and 2 checkboxes should be disabled.so please help me in doing this.i used below code for creating checkboxes and button. i need j script for this <tr> <form ACTION="jspCheckBox.jsp"> SC Information Received <input type="checkbox" value="SC Information received"> Validation Begun <input type="checkbox" value="Validate" > </form> </tr> <tr> <td valign="middle" align="left" style="padding-left:10px;" nowrap> <button type="button" class="btn" name="btnApprove" onclick="approve();">Approve</button> </td> <td> <button type="button" class="btn" name="btnDeny" onclick="deny();">Deny</button> </td> </tr>

    Read the article

  • Remove a ReactiveCocoa signal from a control

    - by dbarros
    If I assign a signal to a property of a control: RAC(self.loginButton.enabled) = [RACSignal combineLatest:@[ self.usernameTextField.rac_textSignal, self.passwordTextField.rac_textSignal ] reduce:^(NSString* username, NSString* password) { return @(username.length > 0 && password.length > 0); }]; But then wanted to assign a different RACSignal to enabled, how can I clear any existing one before doing so? If I try and set it a second time, I get an exception like the following: 2013-10-29 16:54:50.623 myApp[3688:c07] *** Terminating app due to uncaught exception 'NSInternalInconsistencyException', reason: 'Signal <RACSignal: 0x975e9e0> name: +combineLatest: ( "<RACSignal: 0x975d600> name: <UITextField: 0x10f2c420> -rac_textSignal", "<RACSignal: 0x975de30> name: <UITextField: 0x10f306e0> -rac_textSignal" ) reduce: is already bound to key path "self.loginButton.enabled" on object <LoginViewController: 0x10f264e0>, adding signal <RACSignal: 0x9763500> name: +combineLatest: ( "<RACSignal: 0x97624f0> name: <UITextField: 0x10f2c420> -rac_textSignal", "<RACSignal: 0x97629e0> name: <UITextField: 0x10f306e0> -rac_textSignal" ) reduce: is undefined behavior'

    Read the article

  • How to add NT Virtual Machine\Virtual Machines to GPO

    - by Nicola Cassolato
    I have a Windows 2012 Server with Hyper-V enabled and a few virtual machines. My current configuration has a few account in the "Log on as a service" list in the domain policies, and sometimes this prevent my virtual machines from starting (I get this error: 'Error 0x80070569 ('VM_NAME' failed to start worker process: Logon Failure: The user has not been granted the requested logon type at this computer.') As described in this KB I would like to add NT Virtual Machine\Virtual Machines to my "Log on as a service" list to resolve my problem. My problem is that when I try to add that user to my domain policy I get an error message: "The following account could not be validated". My domain controller obviously doesn't know about that user since it's not an Hyper-V enabled server. How can I add that account to my Domain Policies?

    Read the article

  • Apache2 configuration error: "<VirtualHost> was not closed" error

    - by Chris
    So I've already checked through my config file and I really can't see an instance where any tag hasn't been properly closed...but I keep getting this configuration error...Would you mind taking a look through the error and the config file below? Any assistance would be greatly appreciated. FYI, I've already googled the life out of the error and looked through the log extensively, I really can't find anything. Error: apache2: Syntax error on line 236 of /etc/apache2/apache2.conf: syntax error on line 1 of /etc/apache2/sites-enabled/000-default: /etc/apache2/sites-enabled/000-default:1: was not closed. Line 236 of apache2.conf: # Include the virtual host configurations: Include /etc/apache2/sites-enabled/ Contents of 000-default: <VirtualHost *:80> ServerAdmin webmaster@localhost DocumentRoot /var/www <Directory /> Options FollowSymLinks AllowOverride None </Directory> <Directory /var/www/> Options Indexes FollowSymLinks MultiViews AllowOverride None Order allow,deny allow from all </Directory> ScriptAlias /cgi-bin/ /usr/lib/cgi-bin/ <Directory "/usr/lib/cgi-bin"> AllowOverride None Options +ExecCGI -MultiViews +SymLinksIfOwnerMatch Order allow,deny Allow from all </Directory> ErrorLog /var/log/apache2/error.log # Possible values include: debug, info, notice, warn, error, crit, # alert, emerg. LogLevel warn CustomLog /var/log/apache2/access.log combined Alias /doc/ "/usr/share/doc/" <Directory "/usr/share/doc/"> Options Indexes MultiViews FollowSymLinks AllowOverride None Order deny,allow Deny from all Allow from 127.0.0.0/255.0.0.0 ::1/128 </Directory> </VirtualHost> <VirtualHost *:443> SetEnvIf Request_URI "^/u" dontlog ErrorLog /var/log/apache2/error.log Loglevel warn SSLEngine On SSLCertificateFile /etc/apache2/ssl/apache.pem ProxyRequests Off <Proxy *> AuthUserFile /srv/ajaxterm/.htpasswd AuthName EnterPassword AuthType Basic require valid-user Order Deny,allow Allow from all </Proxy> ProxyPass / http://localhost:8022/ ProxyPassReverse / http://localhost:8022/ </VirtualHost> UPDATE I had a load of other issues with my install so I wound up just wiping it and reinstalling. If I run into the same problem, I'll repost. Everyone, thanks for your help/suggestions.

    Read the article

  • Installing WindowsAuthentication breaks authentication / web.config?

    - by Ian Quigley
    I have a clean Windows 2008 R2 box (on a VM) and have installed IIS 7.5 with default options. I then copied a website to it (from Windows 7, IIS 7) and after a little tweaking the website is working fine. The website is currently using and working with Anonymous Authentication. I have gone back to the Windows Components/Sever Manager, Roles - Security and ticked and installed Windows Authentication. When I check my server in IIS (top level above sites) - Authentication, I see Anonymous Authentication (enabled) ASP.NET Impersonation (disabled) Forms Authentication (disbaled) Windows Authentication (enabled) When I check my default website - Authentication, I see as above but "Retrieving status" and an error dialog saying There was an error while performing this operation. Details: Filename c:\inetpub\wwwroot\screwturnwiki\web.config Line number: 96 Error: This configuration section cannot be used in this path. This happens when the section is being locked at the parent level. Locking is either by default (overriderModeDefault="Deny"), or set explicity by a location tag with overrideMode="Deny" or the legacy allowOverride="False". I have tried hand editing the web.config with no success. (How to use locking in IIS7 Configuration) UN-installing Windows Authentication happily returns my site to working with Anonymous Authentication, and allows me to enable/disable these three options. FYI. I am using ScrewTurnWiki with the Active Directory plug in. It all works fine under Windows 7 IIS 7 locally (has been for months) Web.Config <system.webServer> (edit) <handlers> ( deleted removes/adds ) </handlers> <security> <authentication> 96: <windowsAuthentication enabled="true" useKernelMode="true"> <extendedProtection tokenChecking="Allow" /> <providers> <clear /> <add value="NTLM" /> <add value="Negotiate" /> </providers> </windowsAuthentication> </authentication> </security>

    Read the article

  • Batch file script for Enable & disable the "use automatic Configuration Script"

    - by Tijo Joy
    My intention is to create a .bat file that toggles the check box of "use automatic Configuration Script" in Internet Settings. The following is my script @echo OFF setlocal ENABLEEXTENSIONS set KEY_NAME="HKCU\Software\Microsoft\Windows\CurrentVersion\Internet Settings" set VALUE_NAME=AutoConfigURL FOR /F "usebackq skip=1 tokens=1-3" %%A IN (`REG QUERY %KEY_NAME% /v %VALUE_NAME% 2^>nul`) DO ( set ValueName=%%A set ValueType=%%B set ValueValue=%%C ) @echo Value Name = %ValueName% @echo Value Type = %ValueType% @echo Value Value = %ValueValue% IF NOT %ValueValue%==yyyy ( reg add "HKCU\Software\Microsoft\Windows\CurrentVersion\Internet Settings" /v AutoConfigURL /t REG_SZ /d "yyyy" /f echo Proxy Enabled ) else ( echo Hai reg add "HKCU\Software\Microsoft\Windows\CurrentVersion\Internet Settings" /v AutoConfigURL /t REG_SZ /d "" /f echo Proxy Disabled ) The output i'm getting for the Proxy Enabled part is Value Name = AutoConfigURL Value Type = REG_SZ **Value Value =yyyy** Hai The operation completed successfully. Proxy Disabled But the Proxy Enable part isn't working fine the output i get is : Value Name = AutoConfigURL Value Type = REG_SZ **Value Value =** ( was unexpected at this time. The variable "Value Value" is not getting set when we try to do the Proxy enable

    Read the article

  • Setting up a VPN connection to Amazon VPC - routing

    - by Keeno
    I am having some real issues setting up a VPN between out office and AWS VPC. The "tunnels" appear to be up, however I don't know if they are configured correctly. The device I am using is a Netgear VPN Firewall - FVS336GV2 If you see in the attached config downloaded from VPC (#3 Tunnel Interface Configuration), it gives me some "inside" addresses for the tunnel. When setting up the IPsec tunnels do I use the inside tunnel IP's (e.g. 169.254.254.2/30) or do I use my internal network subnet (10.1.1.0/24) I have tried both, when I tried the local network (10.1.1.x) the tracert stops at the router. When I tried with the "inside" ips, the tracert to the amazon VPC (10.0.0.x) goes out over the internet. this all leads me to the next question, for this router, how do I set up stage #4, the static next hop? What are these seemingly random "inside" addresses and where did amazon generate them from? 169.254.254.x seems odd? With a device like this, is the VPN behind the firewall? I have tweaked any IP addresses below so that they are not "real". I am fully aware, this is probably badly worded. Please if there is any further info/screenshots that will help, let me know. Amazon Web Services Virtual Private Cloud IPSec Tunnel #1 ================================================================================ #1: Internet Key Exchange Configuration Configure the IKE SA as follows - Authentication Method : Pre-Shared Key - Pre-Shared Key : --- - Authentication Algorithm : sha1 - Encryption Algorithm : aes-128-cbc - Lifetime : 28800 seconds - Phase 1 Negotiation Mode : main - Perfect Forward Secrecy : Diffie-Hellman Group 2 #2: IPSec Configuration Configure the IPSec SA as follows: - Protocol : esp - Authentication Algorithm : hmac-sha1-96 - Encryption Algorithm : aes-128-cbc - Lifetime : 3600 seconds - Mode : tunnel - Perfect Forward Secrecy : Diffie-Hellman Group 2 IPSec Dead Peer Detection (DPD) will be enabled on the AWS Endpoint. We recommend configuring DPD on your endpoint as follows: - DPD Interval : 10 - DPD Retries : 3 IPSec ESP (Encapsulating Security Payload) inserts additional headers to transmit packets. These headers require additional space, which reduces the amount of space available to transmit application data. To limit the impact of this behavior, we recommend the following configuration on your Customer Gateway: - TCP MSS Adjustment : 1387 bytes - Clear Don't Fragment Bit : enabled - Fragmentation : Before encryption #3: Tunnel Interface Configuration Your Customer Gateway must be configured with a tunnel interface that is associated with the IPSec tunnel. All traffic transmitted to the tunnel interface is encrypted and transmitted to the Virtual Private Gateway. The Customer Gateway and Virtual Private Gateway each have two addresses that relate to this IPSec tunnel. Each contains an outside address, upon which encrypted traffic is exchanged. Each also contain an inside address associated with the tunnel interface. The Customer Gateway outside IP address was provided when the Customer Gateway was created. Changing the IP address requires the creation of a new Customer Gateway. The Customer Gateway inside IP address should be configured on your tunnel interface. Outside IP Addresses: - Customer Gateway : 217.33.22.33 - Virtual Private Gateway : 87.222.33.42 Inside IP Addresses - Customer Gateway : 169.254.254.2/30 - Virtual Private Gateway : 169.254.254.1/30 Configure your tunnel to fragment at the optimal size: - Tunnel interface MTU : 1436 bytes #4: Static Routing Configuration: To route traffic between your internal network and your VPC, you will need a static route added to your router. Static Route Configuration Options: - Next hop : 169.254.254.1 You should add static routes towards your internal network on the VGW. The VGW will then send traffic towards your internal network over the tunnels. IPSec Tunnel #2 ================================================================================ #1: Internet Key Exchange Configuration Configure the IKE SA as follows - Authentication Method : Pre-Shared Key - Pre-Shared Key : --- - Authentication Algorithm : sha1 - Encryption Algorithm : aes-128-cbc - Lifetime : 28800 seconds - Phase 1 Negotiation Mode : main - Perfect Forward Secrecy : Diffie-Hellman Group 2 #2: IPSec Configuration Configure the IPSec SA as follows: - Protocol : esp - Authentication Algorithm : hmac-sha1-96 - Encryption Algorithm : aes-128-cbc - Lifetime : 3600 seconds - Mode : tunnel - Perfect Forward Secrecy : Diffie-Hellman Group 2 IPSec Dead Peer Detection (DPD) will be enabled on the AWS Endpoint. We recommend configuring DPD on your endpoint as follows: - DPD Interval : 10 - DPD Retries : 3 IPSec ESP (Encapsulating Security Payload) inserts additional headers to transmit packets. These headers require additional space, which reduces the amount of space available to transmit application data. To limit the impact of this behavior, we recommend the following configuration on your Customer Gateway: - TCP MSS Adjustment : 1387 bytes - Clear Don't Fragment Bit : enabled - Fragmentation : Before encryption #3: Tunnel Interface Configuration Outside IP Addresses: - Customer Gateway : 217.33.22.33 - Virtual Private Gateway : 87.222.33.46 Inside IP Addresses - Customer Gateway : 169.254.254.6/30 - Virtual Private Gateway : 169.254.254.5/30 Configure your tunnel to fragment at the optimal size: - Tunnel interface MTU : 1436 bytes #4: Static Routing Configuration: Static Route Configuration Options: - Next hop : 169.254.254.5 You should add static routes towards your internal network on the VGW. The VGW will then send traffic towards your internal network over the tunnels. EDIT #1 After writing this post, I continued to fiddle and something started to work, just not very reliably. The local IPs to use when setting up the tunnels where indeed my network subnets. Which further confuses me over what these "inside" IP addresses are for. The problem is, results are not consistent what so ever. I can "sometimes" ping, I can "sometimes" RDP using the VPN. Sometimes, Tunnel 1 or Tunnel 2 can be up or down. When I came back into work today, Tunnel 1 was down, so I deleted it and re-created it from scratch. Now I cant ping anything, but Amazon AND the router are telling me tunnel 1/2 are fine. I guess the router/vpn hardware I have just isnt up to the job..... EDIT #2 Now Tunnel 1 is up, Tunnel 2 is down (I didn't change any settings) and I can ping/rdp again. EDIT #3 Screenshot of route table that the router has built up. Current state (tunnel 1 still up and going string, 2 is still down and wont re-connect)

    Read the article

  • Access FTPS from behind Forefront TMG

    - by Maxim V. Pavlov
    I have a web server on which IIS 7 host an SSL-enabled site. The client in am trying to connect with is behind the corporate Forefront TMG. The app is Total Commander - a file manager shell, that has the ability to connect to SSL FTP by putting a checkmark over SSL/TLS in the FTP connection settings. When FTP Access Filter in FF is enabled, my connection attempt fails on Negociating TLS step of FTP connection. The same happens even if I enable Allow Active FTP in the filter's settings. But when I disable the FTP Access Filter on FF completely, I am able to connect fine. How to configure FF TMG to allow FTPS?

    Read the article

  • With Ubuntu Linux (10+), how do I connect to remote to my machine from Windows

    - by Berlin Brown
    I tried to to remote into my Ubuntu machine. I enabled the setting on Ubuntu and that side seems to work. But I get a connection time out when I use RealVNC on the Windows box. I believe it is a firewall issue. I disabled the firewall for that application on Windows but I don't know how to check if the firewall is enabled on the windows machine. I am on a local network with a router. Ideally, I would want to block that remote control port at the Internet level/router level but "enable" that port on the Windows box and the Ubuntu box. How do I check those settings.

    Read the article

  • dhcp-snooping option 82 drops valid dhcp requests on 2610 series Procurve switches

    - by kce
    We are slowly starting to implement dhcp-snooping on our HP ProCurve 2610 series switches, all running the R.11.72 firmware. I'm seeing some strange behavior where dhcp-request or dhcp-renew packets are dropped when originating from "downstream" switches due "untrusted relay information from client". The full error: Received untrusted relay information from client <mac-address> on port <port-number> In more detail we have a 48 port HP2610 (Switch A) and a 24 port HP2610 (Switch B). Switch B is "downstream" of Switch A by virtue of a DSL connection to one of Switch A ports. The dhcp server is connected to Switch A. The relevant bits are as follows: Switch A dhcp-snooping dhcp-snooping authorized-server 192.168.0.254 dhcp-snooping vlan 1 168 interface 25 name "Server" dhcp-snooping trust exit Switch B dhcp-snooping dhcp-snooping authorized-server 192.168.0.254 dhcp-snooping vlan 1 interface Trk1 dhcp-snooping trust exit The switches are set to trust BOTH the port the authorized dhcp server is attached to and its IP address. This is all well and good for the clients attached to Switch A, but the clients attached to Switch B get denied due to the "untrusted relay information" error. This is odd for a few reasons 1) dhcp-relay is not configured on either switch, 2) the Layer-3 network here is flat, same subnet. DHCP packets should not have a modified option 82 attribute. dhcp-relay does appear to be enabled by default however: SWITCH A# show dhcp-relay DHCP Relay Agent : Enabled Option 82 : Disabled Response validation : Disabled Option 82 handle policy : append Remote ID : mac Client Requests Server Responses Valid Dropped Valid Dropped ---------- ---------- ---------- ---------- 0 0 0 0 SWITCH B# show dhcp-relay DHCP Relay Agent : Enabled Option 82 : Disabled Response validation : Disabled Option 82 handle policy : append Remote ID : mac Client Requests Server Responses Valid Dropped Valid Dropped ---------- ---------- ---------- ---------- 40156 0 0 0 And interestingly enough the dhcp-relay agent seems very busy on Switch B, but why? As far as I can tell there is no reason why dhcp requests need a relay with this topology. And furthermore I can't tell why the upstream switch is dropping legitimate dhcp requests for untrusted relay information when the relay agent in question (on Switch B) isn't modifying the option 82 attributes anyway. Adding the no dhcp-snooping option 82 on Switch A allows the dhcp traffic from Switch B to be approved by Switch A, by virtue of just turning off that feature. What are the repercussions of not validating option 82 modified dhcp traffic? If I disable option 82 on all my "upstream" switches - will they pass dhcp traffic from any downstream switch regardless of that traffic's legitimacy? This behavior is client operating system agnostic. I see it with both Windows and Linux clients. Our DHCP servers are either Windows Server 2003 or Windows Server 2008 R2 machines. I see this behavior regardless of the DHCP servers' operating system. Can anyone shed some light on what's happening here and give me some recommendations on how I should proceed with configuring the option 82 setting? I feel like i just haven't completely grokked dhcp-relaying and option 82 attributes.

    Read the article

  • LSI 9211-8i won't boot in KVM

    - by Paul McMillan
    I'm running ubuntu 11.04 with an LSI 9211-8i in IT mode with the latest firmware (10). I'm using KVM with VT-d enabled to pass the entire PCIe device through to the guest OS. I have the device disabled in the system BIOS. When I boot my virtual machine, the adapter quits during bios initialization with the following error: Unable to load LSI Corporation MPT BIOS MPT BIOS Fault 0Ch encountered at adapter PCI(00h,04h,00h) Press any key to continue... I know the virtualization is correctly enabled. I've blacklisted the kernel modules in the host OS. Has anyone else encountered this error? I'm about out of ideas here. Edit: I contacted LSI tech support about this, and they suggested that I try RedHat and Xen. Apparently they don't test or support anything else.

    Read the article

< Previous Page | 32 33 34 35 36 37 38 39 40 41 42 43  | Next Page >