Search Results

Search found 4049 results on 162 pages for 'serial communication'.

Page 39/162 | < Previous Page | 35 36 37 38 39 40 41 42 43 44 45 46  | Next Page >

  • Realtek RTL8111/8168B wired network doesn't work anymore

    - by Radar4002
    This sounds like it's a common problem upgrading 11.04, but I am having trouble finding a common solution, and one that will work for me. I just applied updates via the update manager and now my wired network connection is down. I know Ubuntu network settings is the issue, because I have a dual-boot with Win 7 and my network/internet is fine on Win 7. I don't know too much about networking, so what can I do to trouble shoot this issue? I can choose an older grub version, 2.6.38-8 instead of 2.6.38-11 and this does not resolve the issue. Here is my lspci result: 00:00.0 Host bridge: ATI Technologies Inc RD890 Northbridge only single slot PCI-e GFX Hydra part (rev 02) 00:02.0 PCI bridge: ATI Technologies Inc RD890 PCI to PCI bridge (PCI express gpp port B) 00:04.0 PCI bridge: ATI Technologies Inc RD890 PCI to PCI bridge (PCI express gpp port D) 00:05.0 PCI bridge: ATI Technologies Inc RD890 PCI to PCI bridge (PCI express gpp port E) 00:06.0 PCI bridge: ATI Technologies Inc RD890 PCI to PCI bridge (PCI express gpp port F) 00:07.0 PCI bridge: ATI Technologies Inc RD890 PCI to PCI bridge (PCI express gpp port G) 00:09.0 PCI bridge: ATI Technologies Inc RD890 PCI to PCI bridge (PCI express gpp port H) 00:0a.0 PCI bridge: ATI Technologies Inc RD890 PCI to PCI bridge (external gfx1 port A) 00:11.0 SATA controller: ATI Technologies Inc SB7x0/SB8x0/SB9x0 SATA Controller [IDE mode] (rev 40) 00:12.0 USB Controller: ATI Technologies Inc SB7x0/SB8x0/SB9x0 USB OHCI0 Controller 00:12.2 USB Controller: ATI Technologies Inc SB7x0/SB8x0/SB9x0 USB EHCI Controller 00:13.0 USB Controller: ATI Technologies Inc SB7x0/SB8x0/SB9x0 USB OHCI0 Controller 00:13.2 USB Controller: ATI Technologies Inc SB7x0/SB8x0/SB9x0 USB EHCI Controller 00:14.0 SMBus: ATI Technologies Inc SBx00 SMBus Controller (rev 41) 00:14.1 IDE interface: ATI Technologies Inc SB7x0/SB8x0/SB9x0 IDE Controller (rev 40) 00:14.2 Audio device: ATI Technologies Inc SBx00 Azalia (Intel HDA) (rev 40) 00:14.3 ISA bridge: ATI Technologies Inc SB7x0/SB8x0/SB9x0 LPC host controller (rev 40) 00:14.4 PCI bridge: ATI Technologies Inc SBx00 PCI to PCI Bridge (rev 40) 00:14.5 USB Controller: ATI Technologies Inc SB7x0/SB8x0/SB9x0 USB OHCI2 Controller 00:15.0 PCI bridge: ATI Technologies Inc Device 43a0 00:16.0 USB Controller: ATI Technologies Inc SB7x0/SB8x0/SB9x0 USB OHCI0 Controller 00:16.2 USB Controller: ATI Technologies Inc SB7x0/SB8x0/SB9x0 USB EHCI Controller 00:18.0 Host bridge: Advanced Micro Devices [AMD] Family 10h Processor HyperTransport Configuration 00:18.1 Host bridge: Advanced Micro Devices [AMD] Family 10h Processor Address Map 00:18.2 Host bridge: Advanced Micro Devices [AMD] Family 10h Processor DRAM Controller 00:18.3 Host bridge: Advanced Micro Devices [AMD] Family 10h Processor Miscellaneous Control 00:18.4 Host bridge: Advanced Micro Devices [AMD] Family 10h Processor Link Control 01:00.0 VGA compatible controller: ATI Technologies Inc Juniper [Radeon HD 5700 Series] 01:00.1 Audio device: ATI Technologies Inc Juniper HDMI Audio [Radeon HD 5700 Series] 02:00.0 USB Controller: NEC Corporation uPD720200 USB 3.0 Host Controller (rev 03) 05:00.0 Ethernet controller: Realtek Semiconductor Co., Ltd. RTL8111/8168B PCI Express Gigabit Ethernet controller (rev 03) 06:00.0 Ethernet controller: Realtek Semiconductor Co., Ltd. RTL8111/8168B PCI Express Gigabit Ethernet controller (rev 03) 07:00.0 SATA controller: JMicron Technology Corp. JMB362/JMB363 Serial ATA Controller (rev 03) 07:00.1 IDE interface: JMicron Technology Corp. JMB362/JMB363 Serial ATA Controller (rev 03) 08:0e.0 FireWire (IEEE 1394): Texas Instruments TSB43AB23 IEEE-1394a-2000 Controller (PHY/Link) 09:00.0 SATA controller: JMicron Technology Corp. JMB362/JMB363 Serial ATA Controller (rev 02) 09:00.1 IDE interface: JMicron Technology Corp. JMB362/JMB363 Serial ATA Controller (rev 02) Here is my sudo lshw -class network: *-network description: Ethernet interface product: RTL8111/8168B PCI Express Gigabit Ethernet controller vendor: Realtek Semiconductor Co., Ltd. physical id: 0 bus info: pci@0000:05:00.0 logical name: eth0 version: 03 serial: 6c:f0:49:e7:72:e8 size: 10Mbit/s capacity: 1Gbit/s width: 64 bits clock: 33MHz capabilities: pm msi pciexpress msix vpd bus_master cap_list rom ethernet physical tp mii 10bt 10bt-fd 100bt 100bt-fd 1000bt 1000bt-fd autonegotiation configuration: autonegotiation=on broadcast=yes driver=r8169 driverversion=2.3LK-NAPI duplex=half latency=0 link=no multicast=yes port=MII speed=10Mbit/s resources: irq:40 ioport:9e00(size=256) memory:fceff000-fcefffff memory:fcef8000-fcefbfff memory:fce00000-fce1ffff *-network description: Ethernet interface product: RTL8111/8168B PCI Express Gigabit Ethernet controller vendor: Realtek Semiconductor Co., Ltd. physical id: 0 bus info: pci@0000:06:00.0 logical name: eth1 version: 03 serial: 6c:f0:49:e7:72:ea size: 10Mbit/s capacity: 1Gbit/s width: 64 bits clock: 33MHz capabilities: pm msi pciexpress msix vpd bus_master cap_list rom ethernet physical tp mii 10bt 10bt-fd 100bt 100bt-fd 1000bt 1000bt-fd autonegotiation configuration: autonegotiation=on broadcast=yes driver=r8169 driverversion=2.3LK-NAPI duplex=half latency=0 link=no multicast=yes port=MII speed=10Mbit/s resources: irq:47 ioport:8e00(size=256) memory:fddff000-fddfffff memory:fddf8000-fddfbfff memory:fdd00000-fdd1ffff

    Read the article

  • XML parsing to plist iPhone SDK

    - by victor
    Hi, guys. Could you, please, help me with parsing of this XML code: <?xml version="1.0" encoding="utf-8"?> <stuff> <parts> <part id='327'> <name>Logitech MX500</name> <serial>618163558491989</serial> <account>ASDALSKD</account> <number>987 789 456</number> <alarm>alarm1</alarm> </part> <part id='846'> <name>Logitech MX510</name> <serial>871351434945431</serial> <account>KJSDAKLJFA</account> <number>454 564 131</number> <alarm>alarm2</alarm> </part> </parts> <info>Information</info> </stuff> And save data to plist file stuff.plist in this format: 327 NSArray Name NSString Logitech MX500 Serial NSString 618163558491989 Account NSString ASDALSKD Number NSString 987 789 456 Alarm NSString alarm1 846 NSArray Name NSString Logitech MX510 Serial NSString 871351434945431 Account NSString KJSDAKLJFA Number NSString 454 564 131 Alarm NSString alarm2

    Read the article

  • how to do display text message from cellphone to textbox

    - by Jiggy Degamo
    I am just making a project automated polling system using sms but i just a beginner of serial communication i have seen a code on the net so i apply it as my guide just a simple text message and display it on the textbox it connects but the provlem is its didn't display on the textbox. here is the code below please help me why it didn't display and please give me a cite that have a tutorial of serial communication using vb.net Imports System.IO.Ports Public Class Form1 Dim inputData As String = "" Private WithEvents serialPort1 As New IO.Ports.SerialPort Public Event DataReceived As IO.Ports.SerialDataReceivedEventHandler Private Sub Form1_FormClosed(ByVal sender As Object, ByVal e As System.Windows.Forms.FormClosedEventArgs) Handles Me.FormClosed ' Close the Serial Port serialPort1.Close() End Sub Private Sub Form1_Load(ByVal sender As Object, ByVal e As System.EventArgs) Handles Me.Load 'Set values for some properties serialPort1.PortName = "COM10" serialPort1.BaudRate = 2400 SerialPort1.Parity = IO.Ports.Parity.None SerialPort1.DataBits = 8 SerialPort1.StopBits = IO.Ports.StopBits.One SerialPort1.Handshake = IO.Ports.Handshake.None SerialPort1.RtsEnable = True ' Open the Serial Port SerialPort1.Open() 'Writes data to the Serial Port output buffer If SerialPort1.IsOpen = True Then SerialPort1.Write("MicroCommand") End If End Sub ' Receive data from the Serial Port 'Show received data on UI controls and do something Public Sub DoUpdate() TextBox1.Text = TextBox1.Text & inputData End Sub Private Sub serialPort1_DataReceived(ByVal sender As Object, ByVal e As System.IO.Ports.SerialDataReceivedEventArgs) Handles serialPort1.DataReceived inputData = serialPort1.ReadExisting 'or serialPort1.ReadLine Me.Invoke(New EventHandler(AddressOf DoUpdate)) End Sub End Class

    Read the article

  • What is causing my spacebar to randomly stop working?

    - by Chris Billington
    A couple of times a day, I'll be typing something and realise I can't type spaces. Usually the cursor will flicker instead when I press the spacebar, and I can type all other letters as far as I can tell. If I'm in a terminal the cursor turns from a solid square to an empty square until I release the spacebar. For some reason, restarting compiz with alt-F2 compiz fixes it, until it next occurs. I can still copy and paste spaces from sources that already have them, and I can still insert spaces with ctrl-shift-u, 20, enter. This has been happening for a while, since before I upgraded to maverick, but it feels like its beceoming more frequent. There really doesn't seem to be any kind of a pattern to it. I'm using 64 bit ubuntu 10.10 on a system76 panp7 laptop. Any ideas how I might troubleshoot? EDIT: using xev, normally a spacebar registers as: KeyPress event, serial 36, synthetic NO, window 0x5600001, root 0x101, subw 0x0, time 26488647, (88,403), root:(748,458), state 0x10, keycode 65 (keysym 0x20, space), same_screen YES, XLookupString gives 1 bytes: (20) " " XmbLookupString gives 1 bytes: (20) " " XFilterEvent returns: False KeyRelease event, serial 36, synthetic NO, window 0x5600001, root 0x101, subw 0x0, time 26488729, (88,403), root:(748,458), state 0x10, keycode 65 (keysym 0x20, space), same_screen YES, XLookupString gives 1 bytes: (20) " " XFilterEvent returns: False But when it's stopped behaving a press of the spacebar instead gives the three events: FocusOut event, serial 36, synthetic NO, window 0x5600001, mode NotifyGrab, detail NotifyAncestor FocusIn event, serial 36, synthetic NO, window 0x5600001, mode NotifyUngrab, detail NotifyAncestor KeymapNotify event, serial 36, synthetic NO, window 0x0, keys: 2 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 FURTHER EDIT: Ok, so I think I've solved the problem, and by that I mean I now know which package to file a bug against. I have a hot corner which initiates a window picker, and I've customised the window picking so that left click goes to a window, right click closes one and spacebar zooms in on one. When I go to this hot corner, compiz must take control of my spacebar, and clearly isn't giving it back when I leave the window picker. So I'll be filing a bug against compiz. reported:here

    Read the article

  • Can't Remove Logical Drive/Array from HP P400

    - by Myles
    This is my first post here. Thank you in advance for any assistance with this matter. I'm trying to remove a logical drive (logical drive 2) and an array (array "B") from my Smart Array P400. The host is a DL580 G5 running 64-bit Red Hat Enterprise Linux Server release 5.7 (Tikanga). I am unable to remove the array using either hpacucli or cpqacuxe. I believe it is because of "OS Status: LOCKED". The file system that lives on this array has been unmounted. I do not want to reboot the host. Is there some way to "release" this logical drive so I can remove the array? Note that I do not need to preserve the data on logical drive 2. I intend to physically remove the drives from the machine and replace them with larger drives. I'm using the cciss kernel module that ships with Red Hat 5.7. Here is some information pertaining to the host and the P400 configuration: [root@gort ~]# cat /etc/redhat-release Red Hat Enterprise Linux Server release 5.7 (Tikanga) [root@gort ~]# uname -a Linux gort 2.6.18-274.el5 #1 SMP Fri Jul 8 17:36:59 EDT 2011 x86_64 x86_64 x86_64 GNU/Linux [root@gort ~]# rpm -qa | egrep '^(hp|cpq)' cpqacuxe-9.30-15.0 hp-health-9.25-1551.7.rhel5 hpsmh-7.1.2-3 hpdiags-9.3.0-466 hponcfg-3.1.0-0 hp-snmp-agents-9.25-2384.8.rhel5 hpacucli-9.30-15.0 [root@gort ~]# hpacucli HP Array Configuration Utility CLI 9.30.15.0 Detecting Controllers...Done. Type "help" for a list of supported commands. Type "exit" to close the console. => ctrl all show config detail Smart Array P400 in Slot 0 (Embedded) Bus Interface: PCI Slot: 0 Cache Serial Number: PA82C0J9SVW34U RAID 6 (ADG) Status: Enabled Controller Status: OK Hardware Revision: D Firmware Version: 7.22 Rebuild Priority: Medium Expand Priority: Medium Surface Scan Delay: 15 secs Surface Scan Mode: Idle Wait for Cache Room: Disabled Surface Analysis Inconsistency Notification: Disabled Post Prompt Timeout: 0 secs Cache Board Present: True Cache Status: OK Cache Ratio: 25% Read / 75% Write Drive Write Cache: Disabled Total Cache Size: 256 MB Total Cache Memory Available: 208 MB No-Battery Write Cache: Disabled Cache Backup Power Source: Batteries Battery/Capacitor Count: 1 Battery/Capacitor Status: OK SATA NCQ Supported: True Logical Drive: 1 Size: 136.7 GB Fault Tolerance: RAID 1 Heads: 255 Sectors Per Track: 32 Cylinders: 35132 Strip Size: 128 KB Full Stripe Size: 128 KB Status: OK Caching: Enabled Unique Identifier: 600508B100184A395356573334550002 Disk Name: /dev/cciss/c0d0 Mount Points: /boot 101 MB, /tmp 7.8 GB, /usr 3.9 GB, /usr/local 2.0 GB, /var 3.9 GB, / 2.0 GB, /local 113.2 GB OS Status: LOCKED Logical Drive Label: A0027AA78DEE Mirror Group 0: physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 146 GB, OK) Mirror Group 1: physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 146 GB, OK) Drive Type: Data Array: A Interface Type: SAS Unused Space: 0 MB Status: OK Array Type: Data physicaldrive 1I:1:1 Port: 1I Box: 1 Bay: 1 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 146 GB Rotational Speed: 10000 Firmware Revision: HPDE Serial Number: 3NM57RF40000983878FX Model: HP DG146BB976 Current Temperature (C): 29 Maximum Temperature (C): 35 PHY Count: 2 PHY Transfer Rate: Unknown, Unknown physicaldrive 1I:1:2 Port: 1I Box: 1 Bay: 2 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 146 GB Rotational Speed: 10000 Firmware Revision: HPDE Serial Number: 3NM55VQC000098388524 Model: HP DG146BB976 Current Temperature (C): 29 Maximum Temperature (C): 36 PHY Count: 2 PHY Transfer Rate: Unknown, Unknown Logical Drive: 2 Size: 546.8 GB Fault Tolerance: RAID 5 Heads: 255 Sectors Per Track: 32 Cylinders: 65535 Strip Size: 64 KB Full Stripe Size: 256 KB Status: OK Caching: Enabled Parity Initialization Status: Initialization Completed Unique Identifier: 600508B100184A395356573334550003 Disk Name: /dev/cciss/c0d1 Mount Points: None OS Status: LOCKED Logical Drive Label: A5C9C6F81504 Drive Type: Data Array: B Interface Type: SAS Unused Space: 0 MB Status: OK Array Type: Data physicaldrive 1I:1:3 Port: 1I Box: 1 Bay: 3 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 146 GB Rotational Speed: 10000 Firmware Revision: HPDE Serial Number: 3NM2H5PE00009802NK19 Model: HP DG146ABAB4 Current Temperature (C): 30 Maximum Temperature (C): 37 PHY Count: 1 PHY Transfer Rate: Unknown physicaldrive 1I:1:4 Port: 1I Box: 1 Bay: 4 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 146 GB Rotational Speed: 10000 Firmware Revision: HPDE Serial Number: 3NM28YY400009750MKPJ Model: HP DG146ABAB4 Current Temperature (C): 31 Maximum Temperature (C): 36 PHY Count: 1 PHY Transfer Rate: 3.0Gbps physicaldrive 2I:1:5 Port: 2I Box: 1 Bay: 5 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 146 GB Rotational Speed: 10000 Firmware Revision: HPDE Serial Number: 3NM2FGYV00009802N3GN Model: HP DG146ABAB4 Current Temperature (C): 30 Maximum Temperature (C): 38 PHY Count: 1 PHY Transfer Rate: Unknown physicaldrive 2I:1:6 Port: 2I Box: 1 Bay: 6 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 146 GB Rotational Speed: 10000 Firmware Revision: HPDE Serial Number: 3NM8AFAK00009920MMV1 Model: HP DG146BB976 Current Temperature (C): 31 Maximum Temperature (C): 41 PHY Count: 2 PHY Transfer Rate: Unknown, Unknown physicaldrive 2I:1:7 Port: 2I Box: 1 Bay: 7 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 146 GB Rotational Speed: 10000 Firmware Revision: HPDE Serial Number: 3NM2FJQD00009801MSHQ Model: HP DG146ABAB4 Current Temperature (C): 29 Maximum Temperature (C): 39 PHY Count: 1 PHY Transfer Rate: Unknown

    Read the article

  • delete key on linux does not work

    - by Gauthier Fleutot
    Hi! My delete key does not work in ubuntu, it does nothing. I understand that this is a common problem, but I could solve it with the information I found elsewhere. I ran xev. Pressing the 'a' key gives: KeyRelease event, serial 30, synthetic NO, window 0x2c00001, root 0x1a6, subw 0x0, time 7255643, (-113,-107), root:(425,300), state 0x2010, keycode 38 (keysym 0x61, a), same_screen YES, XLookupString gives 1 bytes: (61) "a" XFilterEvent returns: False Pressing 'Delete' gives: FocusOut event, serial 30, synthetic NO, window 0x2c00001, mode NotifyGrab, detail NotifyAncestor FocusIn event, serial 30, synthetic NO, window 0x2c00001, mode NotifyUngrab, detail NotifyAncestor KeymapNotify event, serial 30, synthetic NO, window 0x0, keys: 2 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 From there I don't know what to do. Help?

    Read the article

  • Parallel Environment (PE) on Sun Grid Engine (6.2u5) won't run jobs: "only offers 0 slots"

    - by Peter Van Heusden
    I have Sun Grid Engine set up (version 6.2u5) on a Ubuntu 10.10 server with 8 cores. In order to be able to reserve multiple slots, I have a parallel environment (PE) set up like this: pe_name serial slots 999 user_lists NONE xuser_lists NONE start_proc_args /bin/true stop_proc_args /bin/true allocation_rule $pe_slots control_slaves FALSE job_is_first_task TRUE urgency_slots min accounting_summary FALSE This is associated with the all.q on the server in question (let's call the server A). However, when I submit a job that uses 4 threads with e.g. qsub -q all.q@A -pe serial 4 mycmd.sh, it never gets scheduled, and I get the following reasoning from qstat: cannot run in PE "serial" because it only offers 0 slots Why is SGE saying "serial" only offers 0 slots, since there are 8 slots available on the server I specified (server A)? The queue in question is configured thus (server names changed): qname all.q hostlist @allhosts seq_no 0 load_thresholds np_load_avg=1.75 suspend_thresholds NONE nsuspend 1 suspend_interval 00:05:00 priority 0 min_cpu_interval 00:05:00 processors UNDEFINED qtype BATCH INTERACTIVE ckpt_list NONE pe_list make orte serial rerun FALSE slots 1,[D=32],[C=8], \ [B=30],[A=8] tmpdir /tmp shell /bin/sh prolog NONE epilog NONE shell_start_mode posix_compliant starter_method NONE suspend_method NONE resume_method NONE terminate_method NONE notify 00:00:60 owner_list NONE user_lists NONE xuser_lists NONE subordinate_list NONE complex_values NONE projects NONE xprojects NONE calendar NONE initial_state default s_rt INFINITY h_rt 08:00:00 s_cpu INFINITY h_cpu INFINITY s_fsize INFINITY h_fsize INFINITY s_data INFINITY h_data INFINITY s_stack INFINITY h_stack INFINITY s_core INFINITY h_core INFINITY s_rss INFINITY h_rss INFINITY s_vmem INFINITY h_vmem INFINITY,[A=30g], \ [B=5g]

    Read the article

  • Proliant server will not accept new hard disks in RAID 1+0?

    - by Leigh
    I have a HP ProLiant DL380 G5, I have two logical drives configured with RAID. I have one logical drive RAID 1+0 with two 72 gb 10k sas 1 port spare no 376597-001. I had one hard disk fail and ordered a replacement. The configuration utility showed error and would not rebuild the RAID. I presumed a hard disk fault and ordered a replacement again. In the mean time I put the original failed disk back in the server and this started rebuilding. Currently shows ok status however in the log I can see hardware errors. The new disk has come and I again have the same problem of not accepting the hard disk. I have updated the P400 controller with the latest firmware 7.24 , but still no luck. The only difference I can see is the original drive has firmware 0103 (same as the RAID drive) and the new one has HPD2. Any advice would be appreciated. Thanks in advance Logs from server ctrl all show config Smart Array P400 in Slot 1 (sn: PAFGK0P9VWO0UQ) array A (SAS, Unused Space: 0 MB) logicaldrive 1 (68.5 GB, RAID 1, Interim Recovery Mode) physicaldrive 2I:1:1 (port 2I:box 1:bay 1, SAS, 73.5 GB, OK) physicaldrive 2I:1:2 (port 2I:box 1:bay 2, SAS, 72 GB, Failed array B (SAS, Unused Space: 0 MB) logicaldrive 2 (558.7 GB, RAID 5, OK) physicaldrive 1I:1:5 (port 1I:box 1:bay 5, SAS, 300 GB, OK) physicaldrive 2I:1:3 (port 2I:box 1:bay 3, SAS, 300 GB, OK) physicaldrive 2I:1:4 (port 2I:box 1:bay 4, SAS, 300 GB, OK) ctrl all show config detail Smart Array P400 in Slot 1 Bus Interface: PCI Slot: 1 Serial Number: PAFGK0P9VWO0UQ Cache Serial Number: PA82C0J9VWL8I7 RAID 6 (ADG) Status: Disabled Controller Status: OK Hardware Revision: E Firmware Version: 7.24 Rebuild Priority: Medium Expand Priority: Medium Surface Scan Delay: 15 secs Surface Scan Mode: Idle Wait for Cache Room: Disabled Surface Analysis Inconsistency Notification: Disabled Post Prompt Timeout: 0 secs Cache Board Present: True Cache Status: OK Cache Status Details: A cache error was detected. Run more information. Cache Ratio: 100% Read / 0% Write Drive Write Cache: Disabled Total Cache Size: 256 MB Total Cache Memory Available: 208 MB No-Battery Write Cache: Disabled Battery/Capacitor Count: 0 SATA NCQ Supported: True Array: A Interface Type: SAS Unused Space: 0 MB Status: Failed Physical Drive Array Type: Data One of the drives on this array have failed or has Logical Drive: 1 Size: 68.5 GB Fault Tolerance: RAID 1 Heads: 255 Sectors Per Track: 32 Cylinders: 17594 Strip Size: 128 KB Full Stripe Size: 128 KB Status: Interim Recovery Mode Caching: Enabled Unique Identifier: 600508B10010503956574F305551 Disk Name: \\.\PhysicalDrive0 Mount Points: C:\ 68.5 GB Logical Drive Label: A0100539PAFGK0P9VWO0UQ0E93 Mirror Group 0: physicaldrive 2I:1:2 (port 2I:box 1:bay 2, S Mirror Group 1: physicaldrive 2I:1:1 (port 2I:box 1:bay 1, S Drive Type: Data physicaldrive 2I:1:1 Port: 2I Box: 1 Bay: 1 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 73.5 GB Rotational Speed: 10000 Firmware Revision: 0103 Serial Number: B379P8C006RK Model: HP DG072A9B7 PHY Count: 2 PHY Transfer Rate: Unknown, Unknown physicaldrive 2I:1:2 Port: 2I Box: 1 Bay: 2 Status: Failed Drive Type: Data Drive Interface Type: SAS Size: 72 GB Rotational Speed: 15000 Firmware Revision: HPD9 Serial Number: D5A1PCA04SL01244 Model: HP EH0072FARUA PHY Count: 2 PHY Transfer Rate: Unknown, Unknown Array: B Interface Type: SAS Unused Space: 0 MB Status: OK Array Type: Data Logical Drive: 2 Size: 558.7 GB Fault Tolerance: RAID 5 Heads: 255 Sectors Per Track: 32 Cylinders: 65535 Strip Size: 64 KB Full Stripe Size: 128 KB Status: OK Caching: Enabled Parity Initialization Status: Initialization Co Unique Identifier: 600508B10010503956574F305551 Disk Name: \\.\PhysicalDrive1 Mount Points: E:\ 558.7 GB Logical Drive Label: AF14FD12PAFGK0P9VWO0UQD007 Drive Type: Data physicaldrive 1I:1:5 Port: 1I Box: 1 Bay: 5 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 300 GB Rotational Speed: 10000 Firmware Revision: HPD4 Serial Number: 3SE07QH300009923X1X3 Model: HP DG0300BALVP Current Temperature (C): 32 Maximum Temperature (C): 45 PHY Count: 2 PHY Transfer Rate: Unknown, Unknown physicaldrive 2I:1:3 Port: 2I Box: 1 Bay: 3 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 300 GB Rotational Speed: 10000 Firmware Revision: HPD4 Serial Number: 3SE0AHVH00009924P8F3 Model: HP DG0300BALVP Current Temperature (C): 34 Maximum Temperature (C): 47 PHY Count: 2 PHY Transfer Rate: Unknown, Unknown physicaldrive 2I:1:4 Port: 2I Box: 1 Bay: 4 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 300 GB Rotational Speed: 10000 Firmware Revision: HPD4 Serial Number: 3SE08NAK00009924KWD6 Model: HP DG0300BALVP Current Temperature (C): 35 Maximum Temperature (C): 47 PHY Count: 2 PHY Transfer Rate: Unknown, Unknown

    Read the article

  • Reinstalling a fresh Windows 8 on my new laptop

    - by AlexV
    OK I have a new Dell (Inspiron 15R 5520) laptop that came with Windows 8 pre-installed. I'm really not a fan of pre-installed Windows since they are bundled with tons of softwares I don't want and settings I don't like. I would like to reinstall it myself with a fresh installation. I have bought Windows 8 Pro OEM already for my desktop computer and it came with the usual OEM sticker with the Windows serial on it. Now my new laptop only have a Windows 8 logo sticker on it with no serial on it. After some research it seems it's normal. Now, can I format my laptop and install Windows 8 (not pro) from my Windows 8 Pro OEM DVD? I ask because when I installed Windows 8 Pro it asked for the serial (which was found on the sticker). I'm wondering if the same DVD will detect the serial on the BIOS of my new laptop or I need a special Dell DVD for that?

    Read the article

  • lshw tells me my processor is a 64 bits but my motherboard has a 32 bits width

    - by bpetit
    Recently I noticed lshw tells me a strange thing. Here is the first part of my lshw output: bpetit-1025c description: Notebook product: 1025C (1025C) vendor: ASUSTeK COMPUTER INC. version: x.x serial: C3OAAS000774 width: 32 bits capabilities: smbios-2.7 dmi-2.7 smp-1.4 smp configuration: boot=normal chassis=notebook cpus=2 family=Eee PC... *-core description: Motherboard product: 1025C vendor: ASUSTeK COMPUTER INC. physical id: 0 version: x.xx serial: EeePC-0123456789 slot: To be filled by O.E.M. *-firmware description: BIOS vendor: American Megatrends Inc. physical id: 0 version: 1025C.0701 date: 01/06/2012 size: 64KiB capacity: 1984KiB capabilities: pci upgrade shadowing cdboot bootselect socketedrom edd... *-cpu:0 description: CPU product: Intel(R) Atom(TM) CPU N2800 @ 1.86GHz vendor: Intel Corp. physical id: 4 bus info: cpu@0 version: 6.6.1 serial: 0003-0661-0000-0000-0000-0000 slot: CPU 1 size: 798MHz capacity: 1865MHz width: 64 bits clock: 533MHz capabilities: x86-64 boot fpu fpu_exception wp vme de pse tsc ... configuration: cores=2 enabledcores=1 id=2 threads=2 *-cache:0 description: L1 cache physical id: 5 slot: L1-Cache size: 24KiB capacity: 24KiB capabilities: internal write-back unified *-cache:1 description: L2 cache physical id: 6 slot: L2-Cache size: 512KiB capacity: 512KiB capabilities: internal varies unified *-logicalcpu:0 description: Logical CPU physical id: 2.1 width: 64 bits capabilities: logical *-logicalcpu:1 description: Logical CPU physical id: 2.2 width: 64 bits capabilities: logical *-logicalcpu:2 description: Logical CPU physical id: 2.3 width: 64 bits capabilities: logical *-logicalcpu:3 description: Logical CPU physical id: 2.4 width: 64 bits capabilities: logical *-memory description: System Memory physical id: 13 slot: System board or motherboard size: 2GiB *-bank:0 description: SODIMM [empty] product: [Empty] vendor: [Empty] physical id: 0 serial: [Empty] slot: DIMM0 *-bank:1 description: SODIMM DDR3 Synchronous 1066 MHz (0.9 ns) product: SSZ3128M8-EAEEF vendor: Xicor physical id: 1 serial: 00000004 slot: DIMM1 size: 2GiB width: 64 bits clock: 1066MHz (0.9ns) *-cpu:1 physical id: 1 bus info: cpu@1 version: 6.6.1 serial: 0003-0661-0000-0000-0000-0000 size: 798MHz capacity: 798MHz capabilities: ht cpufreq configuration: id=2 *-logicalcpu:0 description: Logical CPU physical id: 2.1 capabilities: logical *-logicalcpu:1 description: Logical CPU physical id: 2.2 capabilities: logical *-logicalcpu:2 description: Logical CPU physical id: 2.3 capabilities: logical *-logicalcpu:3 description: Logical CPU physical id: 2.4 capabilities: logical So here I see my processor is effectively a 64 bits one. However, I'm wondering how my motherboard can have a "32 bits width". I've browsed the web to find an answer, without success. I imagine it's just a technical fact that I don't know about. Thanks.

    Read the article

  • Why is there an extra HDD under /dev being added in my Linux Kernel?

    - by user1279156
    I have created a Linux kernel and for some reason an extra drive is always added at bootup. My hard drive is listed as /dev/sdb. /dev/sda is created too, and it is 8 MB in size. I can't find anything in the kernel config that is creating this, but if I use a different kernel it is not there. Kernel logs show it as an attached SCSI device, looks just like my hard drive but only 8 MB, and has no partition table. It also doesn't appear to be a physical device. I've tried the kernel on many different models of PCs and it is always there. Does anyone know how to remove it? /dev/disk/by-id gives me: scsi-1AMCC_U21413034D98EB000584 scsi-1AMCC_U21413034D98EB000584-part1 scsi-353333330000007d0 scsi-SATA_ST3250312AS_5VY7SH42 scsi-SATA_WDC_WD800JD-60L_WD-WMAM9Y085675 scsi-SATA_WDC_WD800JD-60L_WD-WMAM9Y085675-part1 scsi-SATA_WDC_WD800JD-60L_WD-WMAM9Y085675-part2 hdparm -i /dev/sda gives me an "invalid argument". dd if=/dev/sda of=sda.img the resulting file does not have any content sdparm results: /dev/sda: Linux scsi_debug 0004 Device identification VPD page: Addressed logical unit: designator type: T10 vendor identification, code set: ASCII vendor id: Linux vendor specific: scsi_debug 2000 designator type: NAA, code set: Binary 0x53333330000007d0 Target port: designator type: Relative target port, code set: Binary transport: Serial Attached SCSI (SAS) Relative target port: 0x1 designator type: NAA, code set: Binary transport: Serial Attached SCSI (SAS) 0x52222220000007ce designator type: Target port group, code set: Binary transport: Serial Attached SCSI (SAS) Target port group: 0x100 Target device that contains addressed lu: designator type: NAA, code set: Binary transport: Serial Attached SCSI (SAS) 0x52222220000007cd designator type: SCSI name string, code set: UTF-8 transport: Serial Attached SCSI (SAS) SCSI name string: naa.52222220000007CD

    Read the article

  • Linux Terminal I/O via SPI Device

    - by crankshaft
    Is it possible to create a console using the SPI device (/dev/spidev0.0) in a similar way that you would create a serial console, or if not is this possible ?? GRUB_TERMINAL=serial GRUB_SERIAL_COMMAND="serial --speed=38400 --unit=0 --word=8 --parity=no --stop=1" GRUB_CMDLINE_LINUX_DEFAULT="console=tty0 console=ttyS0,38400n8 ipv6.disable=1" Or would it be possible to redirect input and output to a script or .c binary and have that handle the SPI ?

    Read the article

  • Code Trivia #4

    - by João Angelo
    Got the inspiration for this one in a recent stackoverflow question. What should the following code output and why? class Program { class Author { public string FirstName { get; set; } public string LastName { get; set; } public override string ToString() { return LastName + ", " + FirstName; } } static void Main() { Author[] authors = new[] { new Author { FirstName = "John", LastName = "Doe" }, new Author { FirstName = "Jane", LastName="Doe" } }; var line1 = String.Format("Authors: {0} and {1}", authors); Console.WriteLine(line1); string[] serial = new string[] { "AG27H", "6GHW9" }; var line2 = String.Format("Serial: {0}-{1}", serial); Console.WriteLine(line2); int[] version = new int[] { 1, 0 }; var line3 = String.Format("Version: {0}.{1}", version); Console.WriteLine(line3); } } Update: The code will print the first two lines // Authors: Doe, John and Doe, Jane // Serial: AG27H-6GHW9 and then throw an exception on the third call to String.Format because array covariance is not supported in value types. Given this the third call of String.Format will not resolve to String.Format(string, params object[]), like the previous two, but to String.Format(string, object) which fails to provide the second argument for the specified format and will then cause the exception.

    Read the article

  • Laptop power button not working

    - by DyP
    I have a (seemingly rather exotic) Dell Latitude XT2 notebook running Lubuntu 12.04, fresh install. Tried to get the power button to work as expected (opening lubuntu-logout, just as I think it was meant to be out-of-the box), but no success: power button does nothing but forced power-off on long press. Here some more information, please ask if something more could help: Power button is recognized as a device: xinput lists Power Button as a slave keyboard at /dev/input/event1, and I can run a tool to listen to that device and invoke some action (successfully). But using .config/openbox/lubuntu-rc.xml to assign some action to XF86ShutDown or XF86PowerOff does nothing. Works well for any key of the keyboard. xinput --test reports a keycode (key press, key release) of 124 when pressing & releasing the power button. xmodmap -pk lists 124 mapped to XF86PowerOff which seems correct to me (btw: is this the same as XF86ShutDown?) When assigning another keysymname to the 124 keycode, e.g. 'w', still nothing happens when pressing the power button (no window seems to receive a 'w'). Works well for any key on the keyboard. The outputs of xev for a press/release of the power button irritate me: MappingNotify event, serial 41, synthetic NO, window 0x0, request MappingKeyboard, first_keycode 8, count 248 FocusOut event, serial 41, synthetic NO, window 0x2a00001, mode NotifyGrab, detail NotifyAncestor FocusIn event, serial 41, synthetic NO, window 0x2a00001, mode NotifyUngrab, detail NotifyAncestor KeymapNotify event, serial 41, synthetic NO, window 0x0, keys: 93 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 (instead of 93, I also get different values) I might have missed something very basic since I'm not very familiar with both openbox/lubuntu and the X input system. Btw.: same goes for three other special buttons on my laptop..

    Read the article

  • .NET SerialPort DataReceived event not firing

    - by Klay
    I have a WPF test app for evaluating event-based serial port communication (vs. polling the serial port). The problem is that the DataReceived event doesn't seem to be firing at all. I have a very basic WPF form with a TextBox for user input, a TextBlock for output, and a button to write the input to the serial port. Here's the code: public partial class Window1 : Window { SerialPort port; public Window1() { InitializeComponent(); port = new SerialPort("COM2", 9600, Parity.None, 8, StopBits.One); port.DataReceived += new SerialDataReceivedEventHandler(port_DataReceived); port.Open(); } void port_DataReceived(object sender, SerialDataReceivedEventArgs e) { Debug.Print("receiving!"); string data = port.ReadExisting(); Debug.Print(data); outputText.Text = data; } private void Button_Click(object sender, RoutedEventArgs e) { Debug.Print("sending: " + inputText.Text); port.WriteLine(inputText.Text); } } Now, here are the complicating factors: The laptop I'm working on has no serial ports, so I'm using a piece of software called Virtual Serial Port Emulator to setup a COM2. VSPE has worked admirably in the past, and it's not clear why it would only malfunction with .NET's SerialPort class, but I mention it just in case. When I hit the button on my form to send the data, my Hyperterminal window (connected on COM2) shows that the data is getting through. Yes, I disconnect Hyperterminal when I want to test my form's ability to read the port. I've tried opening the port before wiring up the event. No change. I've read through another post here where someone else is having a similar problem. None of that info has helped me in this case. EDIT: Here's the console version (modified from http://mark.michaelis.net/Blog/TheBasicsOfSystemIOPortsSerialPort.aspx): class Program { static SerialPort port; static void Main(string[] args) { port = new SerialPort("COM2", 9600, Parity.None, 8, StopBits.One); port.DataReceived += new SerialDataReceivedEventHandler(port_DataReceived); port.Open(); string text; do { text = Console.ReadLine(); port.Write(text + "\r\n"); } while (text.ToLower() != "q"); } public static void port_DataReceived(object sender, SerialDataReceivedEventArgs args) { string text = port.ReadExisting(); Console.WriteLine("received: " + text); } } This should eliminate any concern that it's a Threading issue (I think). This doesn't work either. Again, Hyperterminal reports the data sent through the port, but the console app doesn't seem to fire the DataReceived event. EDIT #2: I realized that I had two separate apps that should both send and receive from the serial port, so I decided to try running them simultaneously... If I type into the console app, the WPF app DataReceived event fires, with the expected threading error (which I know how to deal with). If I type into the WPF app, the console app DataReceived event fires, and it echoes the data. I'm guessing the issue is somewhere in my use of the VSPE software, which is set up to treat one serial port as both input and output. And through some weirdness of the SerialPort class, one instance of a serial port can't be both the sender and receiver. Anyway, I think it's solved.

    Read the article

  • Disk Drive not working

    - by user287681
    The CD/DVD drive on my sisters' (I'm helping her shift from Win. XP (now officially deprecated by Microsoft) to Ubuntu) system. Now, it may end up being a failed attempt, all together (Almost the whole last year (when she's been on XP) the disk drive hasn't (not even powering on) been working.), I just want to make sure I've explored every remote possibility. Because I figure, "Huh, now that I've got Ubuntu running, instead of XP, that (just) might make a difference.". I have tried using the sudo lshw command in the terminal, to (seemingly) no avil, but, who knows, you might be able to make something out of it. Here's the output: kyra@kyra-Satellite-P105:~$ sudo lshw [sudo] password for kyra: kyra-satellite-p105 description: Notebook product: Satellite P105 () vendor: TOSHIBA version: PSPA0U-0TN01M serial: 96084354W width: 64 bits capabilities: smbios-2.4 dmi-2.4 vsyscall32 configuration: administrator_password=disabled boot=oem-specific chassis=notebook frontpanel_password=unknown keyboard_password=unknown power-on_password=disabled uuid=00900559-F88E-D811-82E0-00163680E992 *-core description: Motherboard product: Satellite P105 vendor: TOSHIBA physical id: 0 version: Not Applicable serial: 1234567890 *-firmware description: BIOS vendor: TOSHIBA physical id: 0 version: V4.70 date: 01/19/20092 size: 92KiB capabilities: isa pci pcmcia pnp upgrade shadowing escd cdboot acpi usb biosbootspecification *-cpu description: CPU product: Intel(R) Core(TM)2 CPU T5500 @ 1.66GHz vendor: Intel Corp. physical id: 4 bus info: cpu@0 version: Intel(R) Core(TM)2 CPU T5 slot: U2E1 size: 1667MHz capacity: 1667MHz width: 64 bits clock: 166MHz capabilities: fpu fpu_exception wp vme de pse tsc msr pae mce cx8 apic sep mtrr pge mca cmov pat pse36 clflush dts acpi mmx fxsr sse sse2 ss ht tm pbe syscall nx x86-64 constant_tsc arch_perfmon pebs bts rep_good nopl aperfmperf pni dtes64 monitor ds_cpl est tm2 ssse3 cx16 xtpr pdcm lahf_lm dtherm cpufreq *-cache:0 description: L1 cache physical id: 5 slot: L1 Cache size: 16KiB capacity: 16KiB capabilities: asynchronous internal write-back *-cache:1 description: L2 cache physical id: 6 slot: L2 Cache size: 2MiB capabilities: burst external write-back *-memory description: System Memory physical id: c slot: System board or motherboard size: 2GiB capacity: 3GiB *-bank:0 description: SODIMM DDR2 Synchronous physical id: 0 slot: M1 size: 1GiB width: 64 bits *-bank:1 description: SODIMM DDR2 Synchronous physical id: 1 slot: M2 size: 1GiB width: 64 bits *-pci description: Host bridge product: Mobile 945GM/PM/GMS, 943/940GML and 945GT Express Memory Controller Hub vendor: Intel Corporation physical id: 100 bus info: pci@0000:00:00.0 version: 03 width: 32 bits clock: 33MHz configuration: driver=agpgart-intel resources: irq:0 *-display:0 description: VGA compatible controller product: Mobile 945GM/GMS, 943/940GML Express Integrated Graphics Controller vendor: Intel Corporation physical id: 2 bus info: pci@0000:00:02.0 version: 03 width: 32 bits clock: 33MHz capabilities: msi pm vga_controller bus_master cap_list rom configuration: driver=i915 latency=0 resources: irq:16 memory:d0200000-d027ffff ioport:1800(size=8) memory:c0000000-cfffffff memory:d0300000-d033ffff *-display:1 UNCLAIMED description: Display controller product: Mobile 945GM/GMS/GME, 943/940GML Express Integrated Graphics Controller vendor: Intel Corporation physical id: 2.1 bus info: pci@0000:00:02.1 version: 03 width: 32 bits clock: 33MHz capabilities: pm bus_master cap_list configuration: latency=0 resources: memory:d0280000-d02fffff *-multimedia description: Audio device product: NM10/ICH7 Family High Definition Audio Controller vendor: Intel Corporation physical id: 1b bus info: pci@0000:00:1b.0 version: 02 width: 64 bits clock: 33MHz capabilities: pm msi pciexpress bus_master cap_list configuration: driver=snd_hda_intel latency=0 resources: irq:44 memory:d0340000-d0343fff *-pci:0 description: PCI bridge product: NM10/ICH7 Family PCI Express Port 1 vendor: Intel Corporation physical id: 1c bus info: pci@0000:00:1c.0 version: 02 width: 32 bits clock: 33MHz capabilities: pci pciexpress msi pm normal_decode bus_master cap_list configuration: driver=pcieport resources: irq:40 ioport:3000(size=4096) memory:84000000-841fffff ioport:84200000(size=2097152) *-pci:1 description: PCI bridge product: NM10/ICH7 Family PCI Express Port 2 vendor: Intel Corporation physical id: 1c.1 bus info: pci@0000:00:1c.1 version: 02 width: 32 bits clock: 33MHz capabilities: pci pciexpress msi pm normal_decode bus_master cap_list configuration: driver=pcieport resources: irq:41 ioport:4000(size=4096) memory:84400000-846fffff ioport:84700000(size=2097152) *-network description: Wireless interface product: PRO/Wireless 3945ABG [Golan] Network Connection vendor: Intel Corporation physical id: 0 bus info: pci@0000:03:00.0 logical name: wlan0 version: 02 serial: 00:13:02:d6:d2:35 width: 32 bits clock: 33MHz capabilities: pm msi pciexpress bus_master cap_list ethernet physical wireless configuration: broadcast=yes driver=iwl3945 driverversion=3.13.0-29-generic firmware=15.32.2.9 ip=10.110.20.157 latency=0 link=yes multicast=yes wireless=IEEE 802.11abg resources: irq:43 memory:84400000-84400fff *-pci:2 description: PCI bridge product: NM10/ICH7 Family PCI Express Port 3 vendor: Intel Corporation physical id: 1c.2 bus info: pci@0000:00:1c.2 version: 02 width: 32 bits clock: 33MHz capabilities: pci pciexpress msi pm normal_decode bus_master cap_list configuration: driver=pcieport resources: irq:42 ioport:5000(size=4096) memory:84900000-84afffff ioport:84b00000(size=2097152) *-usb:0 description: USB controller product: NM10/ICH7 Family USB UHCI Controller #1 vendor: Intel Corporation physical id: 1d bus info: pci@0000:00:1d.0 version: 02 width: 32 bits clock: 33MHz capabilities: uhci bus_master configuration: driver=uhci_hcd latency=0 resources: irq:23 ioport:1820(size=32) *-usb:1 description: USB controller product: NM10/ICH7 Family USB UHCI Controller #2 vendor: Intel Corporation physical id: 1d.1 bus info: pci@0000:00:1d.1 version: 02 width: 32 bits clock: 33MHz capabilities: uhci bus_master configuration: driver=uhci_hcd latency=0 resources: irq:19 ioport:1840(size=32) *-usb:2 description: USB controller product: NM10/ICH7 Family USB UHCI Controller #3 vendor: Intel Corporation physical id: 1d.2 bus info: pci@0000:00:1d.2 version: 02 width: 32 bits clock: 33MHz capabilities: uhci bus_master configuration: driver=uhci_hcd latency=0 resources: irq:18 ioport:1860(size=32) *-usb:3 description: USB controller product: NM10/ICH7 Family USB UHCI Controller #4 vendor: Intel Corporation physical id: 1d.3 bus info: pci@0000:00:1d.3 version: 02 width: 32 bits clock: 33MHz capabilities: uhci bus_master configuration: driver=uhci_hcd latency=0 resources: irq:16 ioport:1880(size=32) *-usb:4 description: USB controller product: NM10/ICH7 Family USB2 EHCI Controller vendor: Intel Corporation physical id: 1d.7 bus info: pci@0000:00:1d.7 version: 02 width: 32 bits clock: 33MHz capabilities: pm debug ehci bus_master cap_list configuration: driver=ehci-pci latency=0 resources: irq:23 memory:d0544000-d05443ff *-pci:3 description: PCI bridge product: 82801 Mobile PCI Bridge vendor: Intel Corporation physical id: 1e bus info: pci@0000:00:1e.0 version: e2 width: 32 bits clock: 33MHz capabilities: pci subtractive_decode bus_master cap_list resources: ioport:2000(size=4096) memory:d0000000-d00fffff ioport:80000000(size=67108864) *-pcmcia description: CardBus bridge product: PCIxx12 Cardbus Controller vendor: Texas Instruments physical id: 4 bus info: pci@0000:0a:04.0 version: 00 width: 32 bits clock: 33MHz capabilities: pcmcia bus_master cap_list configuration: driver=yenta_cardbus latency=176 maxlatency=5 mingnt=192 resources: irq:17 memory:d0004000-d0004fff ioport:2400(size=256) ioport:2800(size=256) memory:80000000-83ffffff memory:88000000-8bffffff *-firewire description: FireWire (IEEE 1394) product: PCIxx12 OHCI Compliant IEEE 1394 Host Controller vendor: Texas Instruments physical id: 4.1 bus info: pci@0000:0a:04.1 version: 00 width: 32 bits clock: 33MHz capabilities: pm ohci bus_master cap_list configuration: driver=firewire_ohci latency=64 maxlatency=4 mingnt=3 resources: irq:17 memory:d0007000-d00077ff memory:d0000000-d0003fff *-storage description: Mass storage controller product: 5-in-1 Multimedia Card Reader (SD/MMC/MS/MS PRO/xD) vendor: Texas Instruments physical id: 4.2 bus info: pci@0000:0a:04.2 version: 00 width: 32 bits clock: 33MHz capabilities: storage pm bus_master cap_list configuration: driver=tifm_7xx1 latency=64 maxlatency=4 mingnt=7 resources: irq:17 memory:d0005000-d0005fff *-generic description: SD Host controller product: PCIxx12 SDA Standard Compliant SD Host Controller vendor: Texas Instruments physical id: 4.3 bus info: pci@0000:0a:04.3 version: 00 width: 32 bits clock: 33MHz capabilities: pm bus_master cap_list configuration: driver=sdhci-pci latency=64 maxlatency=4 mingnt=7 resources: irq:17 memory:d0007800-d00078ff *-network description: Ethernet interface product: PRO/100 VE Network Connection vendor: Intel Corporation physical id: 8 bus info: pci@0000:0a:08.0 logical name: eth0 version: 02 serial: 00:16:36:80:e9:92 size: 10Mbit/s capacity: 100Mbit/s width: 32 bits clock: 33MHz capabilities: pm bus_master cap_list ethernet physical tp mii 10bt 10bt-fd 100bt 100bt-fd autonegotiation configuration: autonegotiation=on broadcast=yes driver=e100 driverversion=3.5.24-k2-NAPI duplex=half latency=64 link=no maxlatency=56 mingnt=8 multicast=yes port=MII speed=10Mbit/s resources: irq:20 memory:d0006000-d0006fff ioport:2000(size=64) *-isa description: ISA bridge product: 82801GBM (ICH7-M) LPC Interface Bridge vendor: Intel Corporation physical id: 1f bus info: pci@0000:00:1f.0 version: 02 width: 32 bits clock: 33MHz capabilities: isa bus_master cap_list configuration: driver=lpc_ich latency=0 resources: irq:0 *-ide description: IDE interface product: 82801GBM/GHM (ICH7-M Family) SATA Controller [IDE mode] vendor: Intel Corporation physical id: 1f.2 bus info: pci@0000:00:1f.2 version: 02 width: 32 bits clock: 66MHz capabilities: ide pm bus_master cap_list configuration: driver=ata_piix latency=0 resources: irq:19 ioport:1f0(size=8) ioport:3f6 ioport:170(size=8) ioport:376 ioport:18b0(size=16) *-serial UNCLAIMED description: SMBus product: NM10/ICH7 Family SMBus Controller vendor: Intel Corporation physical id: 1f.3 bus info: pci@0000:00:1f.3 version: 02 width: 32 bits clock: 33MHz configuration: latency=0 resources: ioport:18c0(size=32) *-scsi physical id: 1 logical name: scsi0 capabilities: emulated *-disk description: ATA Disk product: ST9250421AS vendor: Seagate physical id: 0.0.0 bus info: scsi@0:0.0.0 logical name: /dev/sda version: SD13 serial: 5TH0B2HB size: 232GiB (250GB) capabilities: partitioned partitioned:dos configuration: ansiversion=5 sectorsize=512 signature=000d7fd5 *-volume:0 description: EXT4 volume vendor: Linux physical id: 1 bus info: scsi@0:0.0.0,1 logical name: /dev/sda1 logical name: / version: 1.0 serial: 13bb4bdd-8cc9-40e2-a490-dbe436c2a02d size: 230GiB capacity: 230GiB capabilities: primary bootable journaled extended_attributes large_files huge_files dir_nlink recover extents ext4 ext2 initialized configuration: created=2014-06-01 17:37:01 filesystem=ext4 lastmountpoint=/ modified=2014-06-01 21:15:21 mount.fstype=ext4 mount.options=rw,relatime,errors=remount-ro,data=ordered mounted=2014-06-01 21:15:21 state=mounted *-volume:1 description: Extended partition physical id: 2 bus info: scsi@0:0.0.0,2 logical name: /dev/sda2 size: 2037MiB capacity: 2037MiB capabilities: primary extended partitioned partitioned:extended *-logicalvolume description: Linux swap / Solaris partition physical id: 5 logical name: /dev/sda5 capacity: 2037MiB capabilities: nofs *-remoteaccess UNCLAIMED vendor: Intel physical id: 1 capabilities: inbound kyra@kyra-Satellite-P105:~$

    Read the article

  • While installing updates I get "Package operation Failed" for ubuntu 12.04

    - by user54395
    i get the following response in the details:- Please help nstallArchives() failed: perl: warning: Setting locale failed. perl: warning: Please check that your locale settings: LANGUAGE = (unset), LC_ALL = (unset), LANG = "en_IN.ISO8859-1" are supported and installed on your system. perl: warning: Falling back to the standard locale ("C"). locale: Cannot set LC_CTYPE to default locale: No such file or directory locale: Cannot set LC_MESSAGES to default locale: No such file or directory locale: Cannot set LC_ALL to default locale: No such file or directory perl: warning: Setting locale failed. perl: warning: Please check that your locale settings: LANGUAGE = (unset), LC_ALL = (unset), LANG = "en_IN.ISO8859-1" are supported and installed on your system. perl: warning: Falling back to the standard locale ("C"). locale: Cannot set LC_CTYPE to default locale: No such file or directory locale: Cannot set LC_MESSAGES to default locale: No such file or directory locale: Cannot set LC_ALL to default locale: No such file or directory perl: warning: Setting locale failed. perl: warning: Please check that your locale settings: LANGUAGE = (unset), LC_ALL = (unset), LANG = "en_IN.ISO8859-1" are supported and installed on your system. perl: warning: Falling back to the standard locale ("C"). locale: Cannot set LC_CTYPE to default locale: No such file or directory locale: Cannot set LC_MESSAGES to default locale: No such file or directory locale: Cannot set LC_ALL to default locale: No such file or directory perl: warning: Setting locale failed. perl: warning: Please check that your locale settings: LANGUAGE = (unset), LC_ALL = (unset), LANG = "en_IN.ISO8859-1" are supported and installed on your system. perl: warning: Falling back to the standard locale ("C"). locale: Cannot set LC_CTYPE to default locale: No such file or directory locale: Cannot set LC_MESSAGES to default locale: No such file or directory locale: Cannot set LC_ALL to default locale: No such file or directory (Reading database ... (Reading database ... 5%% (Reading database ... 10%% (Reading database ... 15%% (Reading database ... 20%% (Reading database ... 25%% (Reading database ... 30%% (Reading database ... 35%% (Reading database ... 40%% (Reading database ... 45%% (Reading database ... 50%% (Reading database ... 55%% (Reading database ... 60%% (Reading database ... 65%% (Reading database ... 70%% (Reading database ... 75%% (Reading database ... 80%% (Reading database ... 85%% (Reading database ... 90%% (Reading database ... 95%% (Reading database ... 100%% (Reading database ... 427340 files and directories currently installed.) Preparing to replace thunderbird-trunk-globalmenu 14.0~a1~hg20120409r9862.91177-0ubuntu1~umd1 (using .../thunderbird-trunk-globalmenu_14.0~a1~hg20120409r9866.91235-0ubuntu1~umd1_i386.deb) ... Unpacking replacement thunderbird-trunk-globalmenu ... Preparing to replace thunderbird-trunk 14.0~a1~hg20120409r9862.91177-0ubuntu1~umd1 (using .../thunderbird-trunk_14.0~a1~hg20120409r9866.91235-0ubuntu1~umd1_i386.deb) ... Unpacking replacement thunderbird-trunk ... Processing triggers for man-db ... locale: Cannot set LC_CTYPE to default locale: No such file or directory locale: Cannot set LC_MESSAGES to default locale: No such file or directory locale: Cannot set LC_ALL to default locale: No such file or directory Processing triggers for bamfdaemon ... Rebuilding /usr/share/applications/bamf.index... Processing triggers for gnome-menus ... Processing triggers for desktop-file-utils ... Setting up crossplatformui (1.0.27) ... Rather than invoking init scripts through /etc/init.d, use the service(8) utility, e.g. service acpid restart Since the script you are attempting to invoke has been converted to an Upstart job, you may also use the stop(8) and then start(8) utilities, e.g. stop acpid ; start acpid. The restart(8) utility is also available. acpid stop/waiting acpid start/running, process 5286 package libqtgui4 exist QT_VERSION = 4 make -C /lib/modules/3.2.0-22-generic/build M=/usr/local/bin/ztemtApp/zteusbserial/below2.6.27 modules make[1]: Entering directory /usr/src/linux-headers-3.2.0-22-generic' CC [M] /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.o /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:34:28: fatal error: linux/smp_lock.h: No such file or directory compilation terminated. make[2]: *** [/usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.o] Error 1 make[1]: *** [_module_/usr/local/bin/ztemtApp/zteusbserial/below2.6.27] Error 2 make[1]: Leaving directory/usr/src/linux-headers-3.2.0-22-generic' make: * [modules] Error 2 dpkg: error processing crossplatformui (--configure): subprocess installed post-installation script returned error exit status 2 No apport report written because MaxReports is reached already Setting up thunderbird-trunk (14.0~a1~hg20120409r9866.91235-0ubuntu1~umd1) ... Setting up thunderbird-trunk-globalmenu (14.0~a1~hg20120409r9866.91235-0ubuntu1~umd1) ... Errors were encountered while processing: crossplatformui Error in function: SystemError: E:Sub-process /usr/bin/dpkg returned an error code (1) Setting up crossplatformui (1.0.27) ... Rather than invoking init scripts through /etc/init.d, use the service(8) utility, e.g. service acpid restart Since the script you are attempting to invoke has been converted to an Upstart job, you may also use the stop(8) and then start(8) utilities, e.g. stop acpid ; start acpid. The restart(8) utility is also available. acpid stop/waiting acpid start/running, process 5541 package libqtgui4 exist QT_VERSION = 4 make -C /lib/modules/3.2.0-22-generic/build M=/usr/local/bin/ztemtApp/zteusbserial/below2.6.27 modules make[1]: Entering directory /usr/src/linux-headers-3.2.0-22-generic' CC [M] /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.o /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:34:28: fatal error: linux/smp_lock.h: No such file or directory compilation terminated. make[2]: *** [/usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.o] Error 1 make[1]: *** [_module_/usr/local/bin/ztemtApp/zteusbserial/below2.6.27] Error 2 make[1]: Leaving directory/usr/src/linux-headers-3.2.0-22-generic' make: * [modules] Error 2 dpkg: error processing crossplatformui (--configure): subprocess installed post-installation script returned error exit status 2

    Read the article

  • How do I make a USB RS232 dongle show up in /dev/ttyUSB* ?

    - by mtrw
    I have a couple of FTDI based USB to Rs232 serial dongles. Sometimes when I plug them into my Ubuntu 10.04 laptop, they show up as /dev/ttyUSB0 and /dev/ttyUSB1, which is what I want to have happen. But sometimes they don't. When they don't, sometimes rebooting fixes the problem and sometimes it doesn't. They always show up in lsusb hanging off of Bus 5: Bus 005 Device 003: ID 0403:6001 Future Technology Devices International, Ltd FT232 USB-Serial (UART) IC Bus 005 Device 002: ID 0403:6001 Future Technology Devices International, Ltd FT232 USB-Serial (UART) IC Bus 005 Device 001: ID 1d6b:0001 Linux Foundation 1.1 root hub I can see them if I do ls /dev/bus/usb/005 as 002 and 003. But if I pass /dev/bus/usb/005/002 to pyserial, which is what I'm using to access /dev/ttyUSBx, I get SerialException("Could not open port: [Errno 13] Permission denied: '/dev/bus/usb/005/002'",).

    Read the article

  • Handling user interface in a multi-threaded application (or being forced to have a UI-only main thre

    - by Patrick
    In my application, I have a 'logging' window, which shows all the logging, warnings, errors of the application. Last year my application was still single-threaded so this worked [quite] good. Now I am introducing multithreading. I quickly noticed that it's not a good idea to update the logging window from different threads. Reading some articles on keeping the UI in the main thread, I made a communication buffer, in which the other threads are adding their logging messages, and from which the main thread takes the messages and shows them in the logging window (this is done in the message loop). Now, in a part of my application, the memory usage increases dramatically, because the separate threads are generating lots of logging messages, and the main thread cannot empty the communication buffer quickly enough. After the while the memory decreases again (if the other threads have finished their work and the main thread gradually empties the communication buffer). I solved this problem by having a maximum size on the communication buffer, but then I run into a problem in the following situation: the main thread has to perform a complex action the main thread takes some parts of the action and let's separate threads execute this while the seperate threads are executing their logic, the main thread processes the results from the other threads and continues with its work if the other threads are finished Problem is that in this situation, if the other threads perform logging, there is no UI-message loop, and so the communication buffer is filled, but not emptied. I see two solutions in solving this problem: require the main thread to do regular polling of the communication buffer only performing user interface logic in the main thread (no other logic) I think the second solution seems the best, but this may not that easy to introduce in a big application (in my case it performs mathematical simulations). Are there any other solutions or tips? Or is one of the two proposed the best, easiest, most-pragmatic solution? Thanks, Patrick

    Read the article

  • Cloud services can't be reached from complex customer infrastructure

    - by Nock
    We have several services running on a cloud, they all are hosted on Windows Server 2012 R2, have public IP address and specific port. Some of our customers can't reach them because for "some reason" the ports are cut between a firewall between them and us. (some customers are using a shared internet connection in a multi tenant office and they can't change firewall communication) Well, you get it, we don't have the possibility to make all the firewall "allowing" the communication. My customers all runs Windows 7 at least. What is the best counter solution in such case, using Microsoft (Windows Server) technologies? The best would be some kind of tunneling communication or VPN, but the customer should also be able to access his/her enterprise resources. Bby the way, today we using IPSec using Windows Firewall to secure the communication, is IPSec tunneling a solution for us? Otherwise, is there a service in Windows to enable some kind of VPN between a client and a server but only for a given set of servers?

    Read the article

  • spring JDBC

    - by Adhir
    I am getting the following exception whe using derby to do a UPDATE in oracle Database org.springframework.jdbc.CannotGetJdbcConnectionException: Could not get JDBC Connection; nested exception is org.apache.derby.client.am.DisconnectException: A communication error has been detected. Communication protocol being used: Reply.fill(). Communication API being used: InputStream.read(). Location where the error was detected: insufficient data. Communication function detecting the error: *. Protocol specific error codes(s) TCP/IP SOCKETS at org.springframework.jdbc.datasource.DataSourceUtils.getConnection(DataSourceUtils.java:82) at org.springframework.jdbc.core.JdbcTemplate.execute(JdbcTemplate.java:522) at org.springframework.jdbc.core.JdbcTemplate.update(JdbcTemplate.java:737) at org.springframework.jdbc.core.JdbcTemplate.update(JdbcTemplate.java:795) at org.springframework.jdbc.core.JdbcTemplate.update(JdbcTemplate.java:803) at com.poc.data.dao.UserDerbyDao.create(UserDerbyDao.java:19) at com.poc.register.RegisterUtil.registerUser(RegisterUtil.java:34) at com.poc.service.MyService.doRegister(MyService.java:108) at sun.reflect.NativeMethodAccessorImpl.invoke0(Native Method) at sun.reflect.NativeMethodAccessorImpl.invoke(Unknown Source) at sun.reflect.DelegatingMethodAccessorImpl.invoke(Unknown Source) at java.lang.reflect.Method.invoke(Unknown Source) at com.sun.jersey.server.impl.model.method.dispatch.AbstractResourceMethodDispatchProvider$ResponseOutInvoker._dispatch(AbstractResourceMethodDispatchProvider.java:175) at com.sun.jersey.server.impl.model.method.dispatch.ResourceJavaMethodDispatcher.dispatch(ResourceJavaMethodDispatcher.java:67) at com.sun.jersey.server.impl.uri.rules.HttpMethodRule.accept(HttpMethodRule.java:166) at com.sun.jersey.server.impl.uri.rules.RightHandPathRule.accept(RightHandPathRule.java:114) at com.sun.jersey.server.impl.uri.rules.ResourceClassRule.accept(ResourceClassRule.java:74) at com.sun.jersey.server.impl.uri.rules.RightHandPathRule.accept(RightHandPathRule.java:114) at com.sun.jersey.server.impl.uri.rules.RootResourceClassesRule.accept(RootResourceClassesRule.java:66) at com.sun.jersey.server.impl.application.WebApplicationImpl._handleRequest(WebApplicationImpl.java:658) at com.sun.jersey.server.impl.application.WebApplicationImpl.handleRequest(WebApplicationImpl.java:616) at com.sun.jersey.server.impl.application.WebApplicationImpl.handleRequest(WebApplicationImpl.java:607) at com.sun.jersey.spi.container.servlet.WebComponent.service(WebComponent.java:309) at com.sun.jersey.spi.container.servlet.ServletContainer.service(ServletContainer.java:425) at com.sun.jersey.spi.container.servlet.ServletContainer.service(ServletContainer.java:590) at javax.servlet.http.HttpServlet.service(HttpServlet.java:806) at org.apache.catalina.core.ApplicationFilterChain.internalDoFilter(ApplicationFilterChain.java:290) at org.apache.catalina.core.ApplicationFilterChain.doFilter(ApplicationFilterChain.java:206) at org.apache.catalina.core.StandardWrapperValve.invoke(StandardWrapperValve.java:233) at org.apache.catalina.core.StandardContextValve.invoke(StandardContextValve.java:191) at org.apache.catalina.core.StandardHostValve.invoke(StandardHostValve.java:128) at org.apache.catalina.valves.ErrorReportValve.invoke(ErrorReportValve.java:102) at org.apache.catalina.core.StandardEngineValve.invoke(StandardEngineValve.java:109) at org.apache.catalina.connector.CoyoteAdapter.service(CoyoteAdapter.java:286) at org.apache.coyote.http11.Http11Processor.process(Http11Processor.java:845) at org.apache.coyote.http11.Http11Protocol$Http11ConnectionHandler.process(Http11Protocol.java:583) at org.apache.tomcat.util.net.JIoEndpoint$Worker.run(JIoEndpoint.java:447) at java.lang.Thread.run(Unknown Source) Caused by: org.apache.derby.client.am.DisconnectException: A communication error has been detected. Communication protocol being used: Reply.fill(). Communication API being used: InputStream.read(). Location where the error was detected: insufficient data. Communication function detecting the error: *. Protocol specific error codes(s) TCP/IP SOCKETS at org.apache.derby.client.net.NetAgent.throwCommunicationsFailure(Unknown Source) at org.apache.derby.client.net.Reply.fill(Unknown Source) at org.apache.derby.client.net.Reply.ensureALayerDataInBuffer(Unknown Source) at org.apache.derby.client.net.Reply.readDssHeader(Unknown Source) at org.apache.derby.client.net.Reply.startSameIdChainParse(Unknown Source) at org.apache.derby.client.net.NetConnectionReply.readExchangeServerAttributes(Unknown Source) at org.apache.derby.client.net.NetConnection.readServerAttributesAndKeyExchange(Unknown Source) at org.apache.derby.client.net.NetConnection.flowServerAttributesAndKeyExchange(Unknown Source) at org.apache.derby.client.net.NetConnection.flowUSRIDPWDconnect(Unknown Source) at org.apache.derby.client.net.NetConnection.flowConnect(Unknown Source) at org.apache.derby.client.net.NetConnection.(Unknown Source) at org.apache.derby.jdbc.ClientDriver.connect(Unknown Source) at java.sql.DriverManager.getConnection(Unknown Source) at java.sql.DriverManager.getConnection(Unknown Source) at org.springframework.jdbc.datasource.DriverManagerDataSource.getConnectionFromDriverManager(DriverManagerDataSource.java:291) at org.springframework.jdbc.datasource.DriverManagerDataSource.getConnectionFromDriverManager(DriverManagerDataSource.java:277) at org.springframework.jdbc.datasource.DriverManagerDataSource.getConnectionFromDriverManager(DriverManagerDataSource.java:259) at org.springframework.jdbc.datasource.DriverManagerDataSource.getConnection(DriverManagerDataSource.java:240) at org.springframework.jdbc.datasource.DataSourceUtils.doGetConnection(DataSourceUtils.java:113) at org.springframework.jdbc.datasource.DataSourceUtils.getConnection(DataSourceUtils.java:79) ... 37 more Any help Thanks in advance Adhir

    Read the article

  • SAT Thread and Process output capture in c#

    - by alex
    Hi: This is a strange problem I encountered. I have an window application written in c# to do testing. It has a MDI parent form that is hosting a few children forms. One of the forms launch test cripts by creating processes and capture the scripts output to a text box. Another form open serial port and monitoring the status of the device I am working on(like a shell). If I ran both of them together, the output of the script seems only appear in the text box after the test is done. However, If I don't open the serial port form, the output of the script is captured in real time. Does anyone knows what's causing the problem? I notice the onDataReceived even handler for serial port form has a [SAThread] header to it. Will this cause the serial port thread having higher priority than other processes? Thanks in advance.

    Read the article

  • "this device cannot start error code 10" ?

    - by Neo
    I am trying to install GPS driver for gmm-u1lp.I think which is just a virtual com port driver. It just contains following INF file: [Version] Signature="$Windows NT$" Class=Ports ClassGuid={4D36E978-E325-11CE-BFC1-08002BE10318} Provider=%MTK% ;LayoutFile=layout.inf DriverVer=06/12/2007,1.0.0.1 [Manufacturer] %MTK%=MTK [MTK] %MTK3329%=Reader,USB\Vid_0e8d&Pid_3329 [Reader_Install.NTx86] ;Windows2000 [DestinationDirs] DefaultDestDir=12 Reader.NT.Copy=12 [Reader.NT] Include=mdmcpq.inf CopyFiles=FakeModemCopyFileSection AddReg=Reader.NT.AddReg [Reader.NT.AddReg] HKR,,DevLoader,,*ntkern HKR,,NTMPDriver,,usbser.sys HKR,,EnumPropPages32,,"MsPorts.dll,SerialPortPropPageProvider" [Reader.NT.Services] AddService = usbser, 0x00000002, Service_Inst [Service_Inst] DisplayName = %Serial.SvcDesc% ServiceType = 1 ; SERVICE_KERNEL_DRIVER StartType = 3 ; SERVICE_DEMAND_START ErrorControl = 1 ; SERVICE_ERROR_NORMAL ServiceBinary = %12%\usbser.sys LoadOrderGroup = Base [Strings] MTK = "Media Tek Inc." MTK3329 = "GPS USB Serial Interface Driver" Serial.SvcDesc = "GPS USB Serial Interface Driver" After installing this Inf,device details shows:"device cannot start error code 10". What is the exact problem? Do I need to test this after connecting the Device?

    Read the article

  • How can I fix "[Error 6] The handle is invalid." with PySerial

    - by alnorth29
    I'm trying to connect to my phone from my Windows 7 PC using PySerial with the following code: import wmi import serial c = wmi.WMI() modem = c.query("SELECT * FROM Win32_POTSModem").pop() ser = serial.Serial(modem.AttachedTo, modem.MaxBaudRateToSerialPort) try: ser.write('at \r\n') print ser.readline() finally: ser.close() But get the following error on the write call: Traceback (most recent call last): File "D:\Alasdair\Documents\Python Scripts\Phone Interface\test.py", line 14, in <module> ser.write('at \r\n') File "C:\Python26\Lib\site-packages\serial\serialwin32.py", line 255, in write raise SerialException("WriteFile failed (%s)" % ctypes.WinError()) SerialException: WriteFile failed ([Error 6] The handle is invalid.) I've tried connecting with TeraTerm and that works fine, so it's not a problem with the connection to the phone itself. I've been searching around for ages trying to find a solution but haven't come up with anything that works. Any ideas?

    Read the article

  • How should I define a composite foreign key for domain constraints in the presence of surrogate keys

    - by Samuel Danielson
    I am writing a new app with Rails so I have an id column on every table. What is the best practice for enforcing domain constraints using foreign keys? I'll outline my thoughts and frustration. Here's what I would imagine as "The Rails Way". It's what I started with. Companies: id: integer, serial company_code: char, unique, not null Invoices: id: integer, serial company_id: integer, not null Products: id: integer, serial sku: char, unique, not null company_id: integer, not null LineItems: id: integer, serial invoice_id: integer, not null, references Invoices (id) product_id: integer, not null, references Products (id) The problem with this is that a product from one company might appear on an invoice for a different company. I added a (company_id: integer, not null) to LineItems, sort of like I'd do if only using natural keys and serials, then added a composite foreign key. LineItems (product_id, company_id) references Products (id, company_id) LineItems (invoice_id, company_id) references Invoices (id, company_id) This properly constrains LineItems to a single company but it seems over-engineered and wrong. company_id in LineItems is extraneous because the surrogate foreign keys are already unique in the foreign table. Postgres requires that I add a unique index for the referenced attributes so I am creating a unique index on (id, company_id) in Products and Invoices, even though id is simply unique. The following table with natural keys and a serial invoice number would not have these issues. LineItems: company_code: char, not null sku: char, not null invoice_id: integer, not null I can ignore the surrogate keys in the LineItems table but this also seems wrong. Why make the database join on char when it has an integer already there to use? Also, doing it exactly like the above would require me to add company_code, a natural foreign key, to Products and Invoices. The compromise... LineItems: company_id: integer, not null sku: integer, not null invoice_id: integer, not null does not require natural foreign keys in other tables but it is still joining on char when there is a integer available. Is there a clean way to enforce domain constraints with foreign keys like God intended, but in the presence of surrogates, without turning the schema and indexes into a complicated mess?

    Read the article

< Previous Page | 35 36 37 38 39 40 41 42 43 44 45 46  | Next Page >