  • Setup of HP ProCurve 2810-24G for iSCSI?

    - by 3molo
    Hi, I have a pair of ProCurve 2810-24G that I will use with a Dell Equallogic SAN and Vmware ESXi. Since ESXi does MPIO, I am a little uncertain on the configuration for links between the switches. Is a trunk the right way to go between the switches? I know that the ports for the SAN and the ESXi hosts should be untagged, so does that mean that I want tagged VLAN on the trunk ports? This is more or less the configuration: trunk 1-4 Trk1 Trunk snmp-server community "public" Unrestricted vlan 1 name "DEFAULT_VLAN" untagged 24,Trk1 ip address 10.180.3.1 255.255.255.0 no untagged 5-23 exit vlan 801 name "Storage" untagged 5-23 tagged Trk1 jumbo exit no fault-finder broadcast-storm stack commander "sanstack" spanning-tree spanning-tree Trk1 priority 4 spanning-tree force-version RSTP-operation The Equallogic PS4000 SAN has two controllers, with two network interfaces each. Dell recommends each controller to be connected to each of the switches. From vmware documentation, it seems creating one vmkernel per pNIC is recommended. With MPIO, this could allow for more than 1 Gbps throughput.

    Read the article

  • How to force iscsi initiator to login only once

    - by Disco
    Trying to setup a few CentOS nodes to connect to a Dell MD3600i array, i'm running into the issue that the MD3600i shows 4 different portals (with different IP addresses) and when i launch the initiator on host side well, it connects to every IP address it has seen during the discovery phase; resulting in duplicates. How can I 'force' the initiator to discard every other IP and let me choose only one IP portal to connect to ? Must be damn stupid but I can't figure out how. Thx

    Read the article

  • How to get physical partition name from iSCSI details on Windows?

    - by Barry Kelly
    I've got a piece of software that needs the name of a partition in \Device\Harddisk2\Partition1 style, as shown e.g. in WinObj. I want to get this partition name from details of the iSCSI connection that underlies the partition. The trouble is that disk order is not fixed - depending on what devices are connected and initialized in what order, it can move around. So suppose I have the portal name (DNS of the iSCSI target), target IQN, etc. I'd like to somehow discover which volumes in the system relate to it, in an automated fashion. I can write some PowerShell WMI queries that get somewhat close to the desired info: PS> get-wmiobject -class Win32_DiskPartition NumberOfBlocks : 204800 BootPartition : True Name : Disk #0, Partition #0 PrimaryPartition : True Size : 104857600 Index : 0 ... From the Name here, I think I can fabricate the corresponding name by adding 1 to the partition number: \Device\Harddisk0\Partition1 - Partition0 appears to be a fake partition mapping to the whole disk. But the above doesn't have enough information to map to the underlying physical device, unless I take a guess based on exact size matching. I can get some info on SCSI devices, but it's not helpful in joining things up (iSCSI target is Nexenta/Solaris COMSTAR): PS> get-wmiobject -class Win32_SCSIControllerDevice __GENUS : 2 __CLASS : Win32_SCSIControllerDevice ... Antecedent : \\COBRA\root\cimv2:Win32_SCSIController.DeviceID="ROOT\\ISCSIPRT\\0000" Dependent : \\COBRA\root\cimv2:Win32_PnPEntity.DeviceID="SCSI\\DISK&VEN_NEXENTA&PROD_COMSTAR... Similarly, I can run queries like these: PS> get-wmiobject -namespace ROOT\WMI -class MSiSCSIInitiator_TargetClass PS> get-wmiobject -namespace ROOT\WMI -class MSiSCSIInitiator_PersistentDevices These guys return information relating to my iSCSI target name and the GUID volume name respectively (a volume name like \\?\Volume{guid-goes-here}), but the GUID volume name is no good to me, and there doesn't appear to be a reliable correspondence between the target name and the volume that I can join on. I simply can't find an easy way of getting from an IQN (e.g. iqn.1992-01.com.example:storage:diskarrays-sn-a8675309) to physical partitions mapped from that target. The way I do it by hand? I start Disk Management, and look for a partition of the correct size, verify that its driver says NEXENTA COMSTAR, and look at the disk number. But even this is unreliable if I have multiple iSCSI volumes of the exact same size. Any suggestions?

    Read the article

  • Can any iSCSI NAS appliance replicate / clone a LUN to an external drive?

    - by Boden
    I would like to backup using Windows Imaging to some kind of NAS appliance. I believe this will require the NAS to support iSCSI. I would then like the appliance to support the replication of the iSCSI LUN to an external eSATA or USB disk connected directly to the appliance. I've found plenty of NAS appliances that can do iSCSI and replicate to an external drive, but none that I've found thus far can do both at once. That is, the devices can do iSCSI, but then the replication feature doesn't work. The idea here is to backup to an appliance located in a secure office far away from the server room. Offsite backups to external hard drive could be managed from the appliance. The benefits of such a setup would be: 1) very unlikely that fire or random theft would affect both server-room backup and "remote" backup appliance 2) offsite backups could be managed by multiple trusted people without granting access to server room 3) Windows imaging provides poor man's deduplication, so each backup volume can contain a decent backup history. I understand why this would be a non-trivial thing to implement, but I'm wondering if such a thing exists? Preferably a tabletop, low to medium cost device. Alternative solutions welcome. NOTE: I'm backing up very few but very large files, so file replication is not a good option.

    Read the article

  • Cheapest iSCSI SAN for Windows 2008/SQL Server clustering?

    - by MichaelGG
    Are there any production-quality iSCSI SANs suitable for use with Windows Server 2008/SQL Server for failover clustering? So far, I've only seen Dell's MD3000i, and HP's MSA 2000 (2012i), which both are around $6K with a minimal disk configuration. Buffalo (yea, I know), has a $1000 device with iSCSI support, but they say it will not work for 2008 failover clustering. I'm interested in seeing something suitable for failover in a production environment, but with very low IO requirements. (Clustering, say, a 30GB DB.) As for using software: On Windows, StarWind seems to have a great solution. But it's actually more money than buying a hardware SAN. (As I understand, only the enterprise edition supports having replicas, and that's $3000 a license.) I was thinking I could use Linux, something like DRBD + an iSCSI target would be fine. However, I haven't seen any free or low-cost iSCSI software that supports SCSI-3 persistent reservations, which Windows 2008 needs for failover clustering. I know $6K isn't much at all, just curious to see if there are practical cheaper solutions out there. And finally, yes, the software is expensive, but many small business get MS BizSpark, so the Windows 2008 Enterprise / SQL 2008 licenses are completely free.

    Read the article

  • Can any iSCSI NAS appliance replicate / clone a LUN to an external drive?

    - by Boden
    I would like to backup using Windows Imaging to some kind of NAS appliance. I believe this will require the NAS to support iSCSI. I would then like the appliance to support the replication of the iSCSI LUN to an external eSATA or USB disk connected directly to the appliance. I've found plenty of NAS appliances that can do iSCSI and replicate to an external drive, but none that I've found thus far can do both at once. That is, the devices can do iSCSI, but then the replication feature doesn't work. The idea here is to backup to an appliance located in a secure office far away from the server room. Offsite backups to external hard drive could be managed from the appliance. The benefits of such a setup would be: 1) very unlikely that fire or random theft would affect both server-room backup and "remote" backup appliance 2) offsite backups could be managed by multiple trusted people without granting access to server room 3) Windows imaging provides poor man's deduplication, so each backup volume can contain a decent backup history. I understand why this would be a non-trivial thing to implement, but I'm wondering if such a thing exists? Preferably a tabletop, low to medium cost device. Alternative solutions welcome. NOTE: I'm backing up very few but very large files, so file replication is not a good option.

    Read the article

  • VMWare vSphere 5: 4 pNICs for iSCSI vs. 2 pNICs

    - by gravyface
    New SAN for me, never used before: it's an IBM DS3512, dual controller with a quad 1GbE NIC per controller that a client bought and needs help setting up. Hosts (x2) have 8 pNICs and while I usually reserve 2 pNICs for iSCSI per host (and 2 for VM, 2 for management, 2 for vMotion, staggered across adapters), these extra ports on the SAN have me wondering if storage I/O would be significantly improved with 2 additional NICs per host, or if the limitations of the vmkernel/initiator would prevent the additional multipaths from ever being realized. I'm not seeing alot of 4 pNIC iSCSI implementations per host; 2 is the de facto standard from what I've read/seen online. I could and probably will do some I/O testing, but just wondering if there's a "wall" that someone else has discovered long ago (i.e. before 10GbE) that makes a 4 NIC iSCSI per host setup somewhat pointless. Just to clarify: I'm not looking for a how-to, but an explanation (link to paper, VMWare recommendation, benchmark, etc.) as to why 2-NIC configurations are the norm vs. 4-NIC iSCSI configurations. i.e. storage vendor limitations, VMKernel/initiator limitations, etc.

    Read the article

  • ESX3.5 Cluster & MD3000i -- Both servers see iSCSI Targets, Only one server can use partition.

    - by GruffTech
    Alright. First and foremost, Warning. This is a bigger-then-normal question. I like to be thorough and try to eliminate all possible "easymode" answers, as well as give everyone a feel of what i've tried. I've included several images of our setup and the problem it is having.. TLDR Version: So I've followed the guides located here: ESX Deployment Guide V1 this is the guide Dell has sent me to setup two ESX3.5 servers mounting a Dell MD3000i. It doesn't work. Both servers can't use the same storage partition on the MD3000. Both servers see it, but only one server can actually use it. (that server being whatever server created the partition on the target.) Both ESX servers are members of the Host Group. Full Version I have 2 ESX3.5 Servers (10.0.7.102, also called EPI2, and 10.0.7.103, also called EPI3.) connected to a iSCSI SAN Device (Dell MD3000i). Both ESX servers can "scan" the SAN and see the LUNS. Part One: MD3000i Storage On the MD3000i, Both servers are in my host group. I have two partitions, VM1 and VM2, both 1.6TB (vmware doesn't like anything past 2tb.) And you can even see that the ESX servers are targetting the MD3000 just fine. Part Two: The ESX Servers Figure 1. So as you can see above, Both ESX Servers (10.0.7.102 and 10.0.7.103) are able to see and scan the MD3000i SAN. Figure 2. Above is the storage both servers see. I created the storage partition on EPI2 (102). I then Extended the partition to include the second LUN for a grand total of 3.27 TB of storage. When i "rescan" on 103 (the server not mounting the partition), I get the below log in log/messages. Mar 11 10:41:18 epi3 kernel: scsi1: remove-single-device 0 0 0 failed, device busy(4). being the only line that grabs my attentions. (EPI3 is the server name) Mar 11 10:41:04 epi3 vmkiscsid[5436]: Connected to Discovery Address 192.168.130.101 Mar 11 10:41:04 epi3 vmkiscsid[5437]: Connected to Discovery Address 192.168.130.102 Mar 11 10:41:04 epi3 vmkiscsid[5438]: Connected to Discovery Address 192.168.131.101 Mar 11 10:41:04 epi3 vmkiscsid[5439]: Connected to Discovery Address 192.168.131.102 Mar 11 10:41:17 epi3 kernel: scsi singledevice 2 0 0 0 Mar 11 10:41:17 epi3 kernel: Vendor: DELL Model: MD3000i Rev: 0735 Mar 11 10:41:17 epi3 kernel: Type: Direct-Access ANSI SCSI revision: 05 Mar 11 10:41:17 epi3 kernel: VMWARE SCSI Id: Supported VPD pages for sdb : 0x0 0x80 0x83 0x85 0x86 0x87 0xc0 0xc1 0xc2 0xc3 0xc4 0xc8 0xc9 0xca 0xd0 Mar 11 10:41:17 epi3 kernel: VMWARE SCSI Id: Device id info for sdb: 0x1 0x3 0x0 0x10 0x60 0x1 0xe4 0xf0 0x0 0x1a 0x1a 0xa2 0x0 0x0 0x15 0xe2 0x4d 0x75 0xf6 0x99 0x53 0x98 0x0 0x54 0x69 0x71 0x6e 0x2e 0x31 0x39 0x38 0x34 0x2d 0x30 0x35 0x2e 0x63 0x6f 0x6d 0x2e 0x64 0x65 0x6c 0x6c 0x3a 0x70 0x6f 0x77 0x65 0x72 0x76 0x61 0x75 0x6c 0x74 0x2e 0x36 0x30 0x30 0x31 0x65 0x34 0x66 0x30 0x30 0x30 0x31 0x61 0x31 0x61 0x61 0x32 0x30 0x30 0x30 0x30 0x30 0x30 0x30 0x30 0x34 0x37 0x39 0x30 0x36 0x32 0x32 0x65 0x2c 0x74 0x2c 0x30 0x78 0x30 0x30 0x30 0x31 0x30 0x30 0x30 0x30 0x30 0x30 0x30 0x32 0x0 0x0 0x0 0x51 0x94 0x0 0x4 0x0 0x0 0x80 0x1 0x53 0xa8 0x0 0x44 0x69 0x71 0x6e 0x2e 0x31 0x39 0x38 0x34 0x2d 0x30 0x35 0x2e 0x63 0x6f 0x6d 0x2e 0x64 0x65 0x6c 0x6c 0x3a 0x70 0x6f 0x77 0x65 0x72 0x76 0x61 0x75 0x6c 0x74 0x2e 0x36 0x30 0x30 0x31 0x65 0x34 0x66 0x30 0x30 0x30 0x31 0x61 0x31 0x61 0x61 0x32 0x30 0x30 0x30 0x30 0x30 0x30 0x30 0x30 0x34 0x37 0x39 0x30 0x36 0x32 0x32 0x65 0x0 0x0 0x0 0x0 Mar 11 10:41:17 epi3 kernel: VMWARE SCSI Id: Id for sdb 0x60 0x01 0xe4 0xf0 0x00 0x1a 0x1a 0xa2 0x00 0x00 0x15 0xe2 0x4d 0x75 0xf6 0x99 0x4d 0x44 0x33 0x30 0x30 0x30 Mar 11 10:41:17 epi3 kernel: VMWARE: Unique Device attached as scsi disk sdb at scsi2, channel 0, id 0, lun 0 Mar 11 10:41:17 epi3 kernel: Attached scsi disk sdb at scsi2, channel 0, id 0, lun 0 Mar 11 10:41:17 epi3 kernel: scan_scsis starting finish Mar 11 10:41:17 epi3 kernel: SCSI device sdb: 3509329920 512-byte hdwr sectors (1797751 MB) Mar 11 10:41:17 epi3 kernel: sdb: sdb1 Mar 11 10:41:17 epi3 kernel: scan_scsis done with finish Mar 11 10:41:17 epi3 kernel: scsi singledevice 2 0 0 1 Mar 11 10:41:17 epi3 kernel: Vendor: DELL Model: MD3000i Rev: 0735 Mar 11 10:41:17 epi3 kernel: Type: Direct-Access ANSI SCSI revision: 05 Mar 11 10:41:18 epi3 kernel: VMWARE SCSI Id: Supported VPD pages for sdc : 0x0 0x80 0x83 0x85 0x86 0x87 0xc0 0xc1 0xc2 0xc3 0xc4 0xc8 0xc9 0xca 0xd0 Mar 11 10:41:18 epi3 kernel: VMWARE SCSI Id: Device id info for sdc: 0x1 0x3 0x0 0x10 0x60 0x1 0xe4 0xf0 0x0 0x1a 0x1a 0x86 0x0 0x0 0xd 0xb7 0x4d 0x75 0xf2 0x77 0x53 0x98 0x0 0x54 0x69 0x71 0x6e 0x2e 0x31 0x39 0x38 0x34 0x2d 0x30 0x35 0x2e 0x63 0x6f 0x6d 0x2e 0x64 0x65 0x6c 0x6c 0x3a 0x70 0x6f 0x77 0x65 0x72 0x76 0x61 0x75 0x6c 0x74 0x2e 0x36 0x30 0x30 0x31 0x65 0x34 0x66 0x30 0x30 0x30 0x31 0x61 0x31 0x61 0x61 0x32 0x30 0x30 0x30 0x30 0x30 0x30 0x30 0x30 0x34 0x37 0x39 0x30 0x36 0x32 0x32 0x65 0x2c 0x74 0x2c 0x30 0x78 0x30 0x30 0x30 0x31 0x30 0x30 0x30 0x30 0x30 0x30 0x30 0x32 0x0 0x0 0x0 0x51 0x94 0x0 0x4 0x0 0x0 0x80 0x1 0x53 0xa8 0x0 0x44 0x69 0x71 0x6e 0x2e 0x31 0x39 0x38 0x34 0x2d 0x30 0x35 0x2e 0x63 0x6f 0x6d 0x2e 0x64 0x65 0x6c 0x6c 0x3a 0x70 0x6f 0x77 0x65 0x72 0x76 0x61 0x75 0x6c 0x74 0x2e 0x36 0x30 0x30 0x31 0x65 0x34 0x66 0x30 0x30 0x30 0x31 0x61 0x31 0x61 0x61 0x32 0x30 0x30 0x30 0x30 0x30 0x30 0x30 0x30 0x34 0x37 0x39 0x30 0x36 0x32 0x32 0x65 0x0 0x0 0x0 0x0 Mar 11 10:41:18 epi3 kernel: VMWARE SCSI Id: Id for sdc 0x60 0x01 0xe4 0xf0 0x00 0x1a 0x1a 0x86 0x00 0x00 0x0d 0xb7 0x4d 0x75 0xf2 0x77 0x4d 0x44 0x33 0x30 0x30 0x30 Mar 11 10:41:18 epi3 kernel: VMWARE: Unique Device attached as scsi disk sdc at scsi2, channel 0, id 0, lun 1 Mar 11 10:41:18 epi3 kernel: Attached scsi disk sdc at scsi2, channel 0, id 0, lun 1 Mar 11 10:41:18 epi3 kernel: scan_scsis starting finish Mar 11 10:41:18 epi3 kernel: SCSI device sdc: 3509329920 512-byte hdwr sectors (1797751 MB) Mar 11 10:41:18 epi3 kernel: sdc: sdc1 Mar 11 10:41:18 epi3 kernel: scan_scsis done with finish Mar 11 10:41:18 epi3 kernel: scsi1: remove-single-device 0 0 0 failed, device busy(4). Mar 11 10:41:18 epi3 kernel: scsi singledevice 1 0 0 0 Things I've Tried: Removing iSCSI targets from only 103, disabling iSCSI, rebooting, enabled iSCSI, re-adding targets, rescan. Same result. Removing partition on 102, Formatted partition on 103 instead. Same result, except flipped. 103 can use storage, 102 can not. Starting Over. Removing all iSCSI Targets on both ESX Boxes, disabling iSCSI, turning off the firewall for iSCSI, rebooting ESX. Then on the MD3000, Removed the Host Group, Removed the Host-to-Virtual Mappings, Restarted the SAN. Followed the Documentation again, same result. Both servers see the storage, but only one server can use it. Disabling and Re-enabling VMware DRS and HA. Same result. Flat-out turning off VMware DRS and HA, and doing the "start over" step to see if maybe that borked it. Same Result. I'm kinda loosing my mind here, Everything i read online says "just partition it and if the ESX boxes can see the targets, it just works".... well crap. Any ideas, any other things to try? Can anyone atleast point me in the right direction? I'm really tired of working from 1am til 4am (our maintenance hours)

    Read the article

  • What is the most suitable way to manage iSCSI storage for Virtual Environments?

    - by Gabriel Talavera
    We are planning to place a HP MSA P2000 with two FC/iSCSI controllers in our network. We have two options to provide more storage to Virtual Machines (We are running Hyper-V): A) Add iSCSI targets to the Virtual Hosts and then create VHD that we would add to each guest server. B) Directly add iSCSI targets in each guest server. Just wondering if one of those options is better than the other, and which is the common practice in a virtualized environment. Thanks in advance for any input!

    Read the article

  • tradeoffs of iSCSI vs. AFP when using Time Machine with a NAS?

    - by ajit.george
    I'm setting up a home NAS device (Synology DS409) that I'm planning to use for Time Machine backups (amongst other things). What are the tradeoffs between using iSCSI or AFP to mount the backup volume? The Synology wiki suggests that iSCSI is better if the Mac will be frequently disconnected from the network or sleeping, from the point of view of the volume automatically remounting. What about filesystem consistency? Given that unplugging a USB drive without properly unmounting it often requires the Time Machine volume to be repaired, would iSCSI have the same issues? Thanks in advance.

    Read the article

  • tradeoffs of iSCSI vs. AFP when using Time Machine with a NAS?

    - by Ajit George
    I'm setting up a home NAS device (Synology DS409) that I'm planning to use for Time Machine backups (amongst other things). What are the tradeoffs between using iSCSI or AFP to mount the backup volume? The Synology wiki suggests that iSCSI is better if the Mac will be frequently disconnected from the network or sleeping, from the point of view of the volume automatically remounting. What about filesystem consistency? Given that unplugging a USB drive without properly unmounting it often requires the Time Machine volume to be repaired, would iSCSI have the same issues?

    Read the article

  • Rough estimate for speed advantage of SAN-via-fibre to san-via-iSCSI when using VMware vSphere

    - by Dirk Paessler
    We are in the process of setting up two virtualization servers (DELL R710, Dual Quadcore Xeon CPUs at 2.3 Ghz, 48 GB RAM) for VMware VSphere with storage on a SAN (DELL Powervault MD3000i, 10x 500 GB SAS drives, RAID 5) which will be attached via iSCSI on a Gbit Ethernet Switch (DELL Powerconnect 5424, they call it "iSCSI-optimized"). Can anyone give an estimate how much faster a fiber channel based solution would be (or better "feel")? I don't mean the nominal speed advantage, I mean how much faster will virtual machines effectively work? Are we talking twice the speed, five times, 10 times faster? Does it justify the price? PS: We are not talking about heavily used database servers or exchange servers. Most of the virtualized servers run below 3-5% average CPU load.

    Read the article

  • Are there any benefits to using a Distributed vSwitch for iSCSI?

    - by dunxd
    I am designing our vSphere farm - we'll be migrating from ESX 3.5 to 4.1. I plan to set up a new farm using ESXi 4.1, and move the Virtual Machines on the 3.5 farm into it by shutdown, then import. In ESX 3.5 there is no distributed networking, so each host has a vSwitch connected to my SAN NICs, and a port group for the vmkernel. In vSphere (ESXi 4.1) I have the extra option to set up a distributed vSwitch and distributed port groups for vmkernel to access iSCSI storage. Is there any benefit to this, or should I stick to non-distributed networking for iSCSI.

    Read the article

  • Drbd Primary/Primary + iSCSI: accessing to different files avoids split brain?

    - by Eddie C.
    I have a question / curiosity about split-brain on a Drbd Primary/Primary configuration. Supposing two nodes (hosts), host1 and host2 configured with Drbd Primary/Primary and two different shares (NFS, CIFS o iSCSI) of a replicated area (saying /drbd) /drbd/file1.data /drbd/file2.data If a pool of client would access only by host1 share reading and wrinting only file1.data and another pool only by host2 share to file2.data, this scenario should avoid split brain situation in case of one node failure or it's just a conjecture? The final purpose is load balance between the two nodes in normal condition and collapsing to one node only in case of failure. Thank you! Eddie

    Read the article

  • What to look for in a switch with LAN/WAN verses an iSCSI SAN?

    - by Luke
    I'm setting up a VMWare ESXi 5 environment with 3 server nodes. Dell recommended 2x Force10 S60 switches shared (iSCSI SAN, LAN/WAN). The S60 switches are extremely powerful. They have 1.25 GB of buffer cache, < 9us latency. But they are very expensive (online price ~$15k per switch, actual quote a little less). I've been told that "by the book" you should at least have 2 internal switches for SAN, and 2 switches for LAN/WAN (each with a redundant). I know some of the pros and cons of each approach. What I'm wondering is, would it be more cost effective to disjoin the SAN from LAN with less expensive switches? The answer to this question highlights what I should be looking for in a switch for the SAN. What should I be looking for in a LAN/WAN switch, in comparison to the SAN? With the above linked question for the SAN: How is buffer latency measured? When you see 36 MB of buffer cache, is that shared or per port? So 36 MB would be 768kb or 36MB per port? With 3 to 6 servers how much buffer cache do you really need? What else should I be looking at? Our application will be heavily using HTML5 websockets (high number of persistent connections). The amount of data being sent is small; Data sent between client <- server isn't broadcasted (not a chat/IM service). We will be doing some database reporting too (csv export, sums, some joins). We are a small business and on a budget. We'd probably only be able to spend no more than $20k on switches total (2 or 4).

    Read the article

  • ISCSI: Ethernet cable maximum length vs. SCSI command timeout

    - by Jeremy Hajek
    I have a question about a non-optimal setup and the practical implications of this. Ideally you would place the ESXi server right in the same room as the FreeNas white box end of question. My situation is this: I have a run of ~125ft of Cat 5e connecting a ESXi server to a FreeNas whitebox in the server room. I know the distance of the ethernet cable is within the maximum distance for ethernet traffic but I have two questions... Can Cat 5e support gigbit speeds at that distance if the switch on the back end is a linksys SRW-2048? Should I be concerned about the distance causing data read and write timeouts in the SCSI portion--(disk operations of the ESXi)?

    Read the article

  • How to best tune my SAN/Initiators for best performance?

    - by Disco
    Recent owner of a Dell PowerVault MD3600i i'm experiencing some weird results. I have a dedicated 24x 10GbE Switch (PowerConnect 8024), setup to jumbo frames 9K. The MD3600 has 2 RAID controllers, each has 2x 10GbE ethernet nics. There's nothing else on the switch; one VLAN for SAN traffic. Here's my multipath.conf defaults { udev_dir /dev polling_interval 5 selector "round-robin 0" path_grouping_policy multibus getuid_callout "/sbin/scsi_id -g -u -s /block/%n" prio_callout none path_checker readsector0 rr_min_io 100 max_fds 8192 rr_weight priorities failback immediate no_path_retry fail user_friendly_names yes # prio rdac } blacklist { device { vendor "*" product "Universal Xport" } # devnode "^sd[a-z]" } devices { device { vendor "DELL" product "MD36xxi" path_grouping_policy group_by_prio prio rdac # polling_interval 5 path_checker rdac path_selector "round-robin 0" hardware_handler "1 rdac" failback immediate features "2 pg_init_retries 50" no_path_retry 30 rr_min_io 100 prio_callout "/sbin/mpath_prio_rdac /dev/%n" } } And iscsid.conf : node.startup = automatic node.session.timeo.replacement_timeout = 15 node.conn[0].timeo.login_timeout = 15 node.conn[0].timeo.logout_timeout = 15 node.conn[0].timeo.noop_out_interval = 5 node.conn[0].timeo.noop_out_timeout = 10 node.session.iscsi.InitialR2T = No node.session.iscsi.ImmediateData = Yes node.session.iscsi.FirstBurstLength = 262144 node.session.iscsi.MaxBurstLength = 16776192 node.conn[0].iscsi.MaxRecvDataSegmentLength = 262144 After my tests; i can barely come to 200 Mb/s read/write. Should I expect more than that ? Providing it has dual 10 GbE my thoughts where to come around the 400 Mb/s. Any ideas ? Guidelines ? Troubleshooting tips ?

    Read the article

  • XenServer/Center: Shared SRs for hosts not in same pool?

    - by 3molo
    I would like to use the same SRs on XenServer hosts that are not able to be part of the same pool (because of not having the exact same cpu feature set, if I understand it correctly) in order to share templates, being able to (manually) start a host on another node, backing up running hosts on other hardware etc etc. The technology for SR can be any of iSCSI, NFS or CIFS, iSCSI would obviously be preferred. Trying to add an iSCSI volume renders a "This LUN is already in use as SR iSCSI - Shared Storage on pool xxxxxx.". Adding a NFS share on one XS host, creating a template there and then checking another XS host reveals they don't agree on used space etc. Coming from a vSphere world this is quite baffling, but if these are limitations then I will have to rethink some of the concepts for this low budget project.

    Read the article

  • iscsitarget suddenly broken after upgrade of the 12.04 Hardware Stack

    - by RapidWebs
    After an upgrade to the latest Hardware Stack using Ubuntu 12.04, my iscsi service is not longer operational. The error from the service is such: FATAL: Module iscsi_trgt not found. I have learned that I might need to reinstall the package iscsitarget-dkms. this package builds a driver or something during installation, from source. During this build process, it reports and error, and now has also broke my package manager. Here is the relevant output: Building module: cleaning build area.... make KERNELRELEASE=3.13.0-34-generic -C /lib/modules/3.13.0-34-generic/build M=/var/lib/dkms/iscsitarget/1.4.20.2/build........(bad exit status: 2) Error! Bad return status for module build on kernel: 3.13.0-34-generic (i686) Consult /var/lib/dkms/iscsitarget/1.4.20.2/build/make.log for more information. Errors were encountered while processing: iscsitarget E: Sub-process /usr/bin/dpkg returned an error code (1) and this is the information provided by make.log: or iscsitarget-1.4.20.2 for kernel 3.13.0-34-generic (i686) Fri Aug 15 22:07:15 EDT 2014 make: Entering directory /usr/src/linux-headers-3.13.0-34-generic LD /var/lib/dkms/iscsitarget/1.4.20.2/build/built-in.o LD /var/lib/dkms/iscsitarget/1.4.20.2/build/kernel/built-in.o CC [M] /var/lib/dkms/iscsitarget/1.4.20.2/build/kernel/tio.o CC [M] /var/lib/dkms/iscsitarget/1.4.20.2/build/kernel/iscsi.o CC [M] /var/lib/dkms/iscsitarget/1.4.20.2/build/kernel/nthread.o CC [M] /var/lib/dkms/iscsitarget/1.4.20.2/build/kernel/wthread.o /var/lib/dkms/iscsitarget/1.4.20.2/build/kernel/wthread.c: In function ‘worker_thread’: /var/lib/dkms/iscsitarget/1.4.20.2/build/kernel/wthread.c:73:28: error: void value not ignored as it ought to be /var/lib/dkms/iscsitarget/1.4.20.2/build/kernel/wthread.c:74:3: error: implicit declaration of function ‘get_io_context’ [-Werror=implicit-function-declaration] /var/lib/dkms/iscsitarget/1.4.20.2/build/kernel/wthread.c:74:21: warning: assignment makes pointer from integer without a cast [enabled by default] cc1: some warnings being treated as errors make[2]: * [/var/lib/dkms/iscsitarget/1.4.20.2/build/kernel/wthread.o] Error 1 make[1]: * [/var/lib/dkms/iscsitarget/1.4.20.2/build/kernel] Error 2 make: * [module/var/lib/dkms/iscsitarget/1.4.20.2/build] Error 2 make: Leaving directory `/usr/src/linux-headers-3.13.0-34-generic' I am at a loss on how to resolve this issue. any help would be appreciated!

    Read the article

  • Need to set up shared storage for Guest virtual machines that are running on a Xen host

    - by Sajith
    My environment: I am doing these things at home with the purpose of learning about virtualization techniques. My machine have quad core processor that supports Intel-VT and 8GB RAM. XEN is the virtualization platform. In short, all domUs are LVM based. Mainly I have two questions; I need to have shared storage for these VMs. Something like NFS / NAS / iSCSI etc. However, I don't know which one is the best solution. Therefore, can someone tell me which suits best? Please note that, this shared storage need to be accessed by the other physical machines in the network. How to implement the selected solution for question #1? Any tutorials / guidelines / ebooks will be a great help and highly appreciated. Thank you in advance :)

    Read the article

  • RHEL 5 SCSI ADPATEC

    - by Rajiv Sharma
    HI I have RHEL 5 box . and adpatec scsi card connected to it . I can see the adaptor under dsmeg | grep -i scsi dmesg | grep -i scsi SCSI subsystem initialized scsi0 : SCSI emulation for USB Mass Storage devices Type: CD-ROM ANSI SCSI revision: 00 scsi 0:0:0:0: Attached scsi generic sg0 type 5 sr0: scsi3-mmc drive: 0x/0x caddy sr 0:0:0:0: Attached scsi CD-ROM sr0 scsi1 : Adaptec AIC79XX PCI-X SCSI HBA DRIVER, Rev 3.0 aic7901: Ultra320 Wide Channel A, SCSI Id=7, PCI-X 101-133Mhz, 512 SCBs Loading iSCSI transport class v2.0-871. iscsi: registered transport (iser) iscsi: registered transport (cxgb3i) Broadcom NetXtreme II iSCSI Driver bnx2i v2.1.0 (Dec 06, 2009) iscsi: registered transport (bnx2i) scsi2 : Broadcom Offload iSCSI Initiator scsi3 : Broadcom Offload iSCSI Initiator iscsi: registered transport (tcp) iscsi: registered transport (be2iscsi) bnx2i: iSCSI not supported, dev=eth0 bnx2i: iSCSI not supported, dev=eth0 bnx2i: iSCSI not supported, dev=eth1 bnx2i: iSCSI not supported, dev=eth1 but cann't see under cat /proc/scsi/scsi cat /proc/scsi/scsi Attached devices: Host: scsi0 Channel: 00 Id: 00 Lun: 00 Vendor: KVM Model: vmDisk-CD Rev: 0.01 Type: CD-ROM ANSI SCSI revision: 02 all st and sg modules are enable. Anyone please help me thanks advance Rajiv

    Read the article

  • How to connect a VM running on an ESXi host to that host via a VMKernel NIC?

    - by Zac B
    Say I have an ESXi (5.0) host that runs a Linux distribution which hosts iSCSI targets, which contain the images for other VMs which the host will run. When it's used, I'll start the host first, then the iSCSI server, and then refresh all storage targets/HBAs in order to see the provided shares as online. I know it's a strange puzzle-box solution, but I was told to implement it. The ESXi host itself has a gigabit NIC which connects to the outside world. The guest OS (CentOS) supports VMXNet3, however, and if I can, I'd like to use its VMXNET3 NIC to host iSCSI for the ESXi host. How should I go about doing this? I went to create a new virtual network, and selected "VKernel", as it suggested that I use that type of network for SAN traffic, but it is apparently not set up for "self-hosted" SAN hosts, as the new network did not appear as an option to attach the CentOS box's VMXNET3 NIC to. How should I best connect an iSCSI host out to its "parent" ESXi host, if I need a) a 10gb connection, and (optionally) b) a VMKernel network for it?

    Read the article

  • DAS vs SAN storage for serving 2 to 4 nodes

    - by Luke404
    We currently have 4 Linux nodes with local storage, arranged in two active/passive pairs with storage mirrored using DRBD, running virtual machines (actually using Xen Hypervisor) for typical hosting workloads (mail, web, a couple VPS, etc.). We're approaching the (presumed) maximum IOPS of those servers, and we're planning to migrate to an external storage solution with two active nodes, with capacity for up to four active nodes. Since we're an all-Dell shop I've done some research and found the MD3200 / MD3200i products should be the ones we're looking for. We are pretty sure we won't be attaching more than 4 hosts on a single storage and I'm wondering if there is any clear advantage for one or the other. In theory I should be able to attach 4 SAS hosts to a single MD3200 (single links on a single controller MD3200, or dual redundant SAS links from each host to a dual-controller MD3200), or 4 iSCSI hosts to a single MD3200i (directly on its 4 GigE ports without any switch, again with dual links for the dual controller option). Both setups should let us implement live VM migration since all hosts can access all the LUNs at the same time, and also some shared filesystem like GFS2 or OCFS2. Also, both setups should allow full redundancy of the whole system (assuming dual controllers in the storage). One difference I can see is that the DAS solution is actually limited to 4 hosts while the iSCSI one should be able to grow to more hosts (adding two GigE switches to the mix). One point for the iSCSI solution is that it would allow us to start out with our current nodes and upgrade them at a later time (we can't add other SAS controllers, but they already have 4 GigE ports each). With the right (iSCSI|SAS) controllers I should be able to connect diskless nodes and boot them off the external storage which I think is a good thing (get rid of any local storage). On the other hand, I would have thought the SAS one to be cheaper but it seems like an MD3200 actually costs a little less than an MD3200i (?) (please note: I've used Dell gear in my examples since that's what we're looking for but I assume the same goes with other vendors) I would like to know if my assumptions above are correct, and if I'm missing any important difference between the two setups.