  • ZFS SAS/SATA controller recommendations

    - by ewwhite
    I've been working with OpenSolaris and ZFS for 6 months, primarily on a Sun Fire x4540 and standard Dell and HP hardware. One downside to standard Perc and HP Smart Array controllers is that they do not have a true "passthrough" JBOD mode to present individual disks to ZFS. One can configure multiple RAID 0 arrays and get them working in ZFS, but it impacts hotswap capabilities (thus requiring a reboot upon disk failure/replacement). I'm curious as to what SAS/SATA controllers are recommended for home-brewed ZFS JBODs. In addition, how does battery-backed write cache (BBWC) play into the solution?

    Read the article

  • FreeNas running on ESXi - sometimes gets very slugish.

    - by Luma
    Hello everyone, I have a ESXi server (dual quad core, 8GB of DDR3 ram, 6x 1TB WD Blacks running in RAid 5 on the PErc 6/i controller. I have a 64bit freenas VM running, on this VM I keep about 200Gigs of stuff that my windows machines access. every now and then the throughput of this VM just dies, for example right now it can't even handle streaming a song and when I tried to transfer a folder the speed goes from 10-400KB/s. Might I add at this point that the ESXi box has dual gigabit network cards plugged into a good solid gigabit switch and other linux and windows VM's are just fine I have seen speeds over 90MB/s (frequently) The server still has ram left over (plenty actually) and cpu is very low (500-1000mhz) any ideas what could cause this? thanks. Luc

    Read the article

  • What is the advantage of iSCSI over SMB?

    - by sofakng
    At my house I'm running a Hyper-V server with a Windows Server 2008 R2 VM acting as a file server. Files are shared across my network using SMB. (Also, the machine is using a PERC 6/i RAID card but I don't think that's important) I'm thinking about setting up a dedicated SAN (iSCSI) machine and then switching my Hyper-V server to ESXi. What are the advantages of using iSCSI versus SMB? I think I would still need a file server OS (eg. Win 2k8) sharing files via SMB so I'm not sure the end result would be any different than my current setup...

    Read the article

  • Get error (Repair Filesystem) 1 # when I install 4 new Hard drives in RedHat Linux 5 on a Dell PowerEdge 2900

    - by Alos Diallo
    Hi I am using a Dell PowerEdge 2900 running RedHat 5. I had 4 drives in the system using a Raid 5, I purchased and installed 4 more drives keeping the configuration the same. Set up the Vertual disks in PERC 6/i. When I exit out and reboot the system I get the following: fsck.ext3: No such file or dirrectory while trying open /dev/ddb1 [FAILED] ***An error occurred during the file system check. ***Dropping you to a shell; the system will reboot ***when you leave the shell. Then am prompted for the root pw. I enter it and am then prompted with: (Repair filesystem) 1# if I type fdisk -l I get some info on the disk along with: Disk /dev/sdb doesn't contain a valid partition table I am then prompted for (Repair filesystem) 2# If I reboot I am taken to the same screen again. The system was working before this happened. Does anyone know why this is happening and or what I can do to fix it? Thanks

    Read the article

  • Can I install linux has the host in a dell poweredge server (r710)?

    - by bksunday
    I might have a deal on dual six core poweredge server and I'm about to go test its performance but I'm wondering few things which I can't find answers for, and I can't test them before buying the machine. I don't want vmware at all so can I just wipe it and install linux instead, or is it embedded in some parts I have no access to. Will I still be able to update different firmwares (perc controllers, motherboard, etc) on this dell poweredge or does it require to have the vmware esxi installed as the host os. And optionally.. is there any foreseeable problems in doing so?

    Read the article

  • Egyetlen központi metaadat készlet: Oracle BI metaadatok, eloadás az OTN-en

    - by user645740
    Érdemes regisztrálni az Oracle Technology Networkre, ahol a részletesebb tartalom a technikai, muszaki információt is tartalmazza. A termékek technikai elemzése, letöltése, dokumentációja mellett felvett eloadásokat is megtekinthetünk, vezetett termék kipróbálási útmutatókat követve betekintést nyerhetünk a megoldásokba. Egy ilyen oktató anyagot ajánlok most az Oracle Business Intelligence megoldásról, A teljes BI eloadássorozat itt érheto el, kattintson ide: Oracle BI Foundation Suite Overview. Ezen belül is az egységes metaadat kezelésérol: kattintson ide: Lesson 2 - Examining the Metadata Layers. A 10 perces eloadásból megismeri: az Oracle BI EE architektúrát az Oracle BI metaadat készlet három rétegét, amiket egyben kezelünk megismeri az egyes objektumokat a repository kezelo admin eszközzel Az Oracle BI metaadat kezelés fo elonyei: Ezt a metaadat csomagot a BI Server automatikusan kezeli, vele összekapcsolja a fizikai adatforrásokat az üzleti/szak fogalmakkal. Számos különbözo adatforrás kezelheto szimultán, akár teljesen heterogén környezetben is az Oracle BI adatforrásaként. EGYETLEN helyen kell tehát karbantartani a metaadatokat a teljes BI infrastruktúrában, nincs szükség sok "világegyetem" párhuzamos kezelésére. Ezzel költséget és idot spórolnak a felhasználók, a könnyebb áttekintés és karbantartás mellett. Ha a fizikai adatforrások szerkezete változik, minimális változtatás szükséges ehhez az Oracle BI metaadatok egyetlen szintjén. Az Oracle BI megoldással tehát a teljes vállalat kiszolgálható, sok cég konszolidál Oracle BI-ra. Ez az eloadás 10 perc alatt megtekintheto: Lesson 2 - Examining the Metadata Layers A teljes BI eloadássorozat itt érheto el: Oracle BI Foundation Suite Overview

    Read the article

  • Ubuntu 12.04 server froze during the first boot after it was installed.

    - by user69021
    I installed Ubuntu server 12.04 to my new server and it failed on the first boot. It just stopped and I can't proceed any further. Server's specifications: Dell PowerEdge T620 CPU : Xeon E5-2665 2.4G x 2 RAM : 8GB RDIMM, 1333MHz x 12 HDD : 3TB Near Line SAS 7.2K x 8 RAID controller : PERC H710 GPU : NVIDIA Tesla C2075 x 4 I have a screenshot of the screen it stopped on but I cannot attach it because my privilege level is currently too low. ![freeze on boot][1] Here are the last messages while booting. [5.048743] Freeing unused kernel memory : 920k freed [5.049046] Write protecting the kernel read-only data : 12288k [5.052973] Freeing unused kernel memory : 1608k freed [5.056132] Freeing unused kernel memory : 1196k freed Loading, please wait... [5.070236] udevd[218]: starting version 175 Begin: Loading essential drivers ... done. Begin: Running /scripts/init-premount ... done. Begin: Mounting root file system ... Begin: Running /scripts/local-top ... done. [5.089030] megasas: 00.00.06.12-rc1 Wed. Oct. 5 17:00:00 PDT 2011 [5.089518] megasas: 0x1000:0x005b:0x1028:0x1f35: bus 1:slot 0:func 0 [5.089739] megaraid_sas 0000:01:00.0: PCI INT A -> GSI 34 (level, low) -> IRQ 34 [5.089937] megasas: FW now in Ready state [5.090427] dca service started, version 1.12.1 [5.091463] Intel(R) Gigabit Ethernet Network Driver - version 3.2.10-k [5.091578] Copyright (c) 2007-2011 Intel Corporation. [5.091712] igb 0000:06:00.0: PCI INT A -> GSI 16 (level,low) -> IRQ 16 [5.111090] megasas:IOC Init cmd success [5.123124] usb 1-1:new high-speed USB device number 2 using ehci_hcd What can I do about this?

    Read the article

  • Explain difference in SQLIO numbers for RAID 0 versus RAID 5 over 6 disks

    - by markn
    When using the SQLIO benchmark tool on a 4-core Dell server with 6 15k 450GB (fast) drives, RAID 0, we found the max throughput was 2MB per second. But when configured as RAID 5, we get 30 MB per second. It seems that the RAID controller, Dell Perc 5i integrated controller, is maxing out the throughput per disk. With RAID 5, I expect to get a bump due to stripping, but not a 15x difference. Like good programmers, we suspect the hardware , but we could be missing something. This is predominately write traffic.

    Read the article

  • Dispatcher.Invoke not working in .NET 3.0 SP1

    - by Kapil
    I am developing a WPF windows application and am getting into a trouble running the app in .NET 3.0. Everytime that I try to access the System.Windows.Threading.Dispatcher.Invoke() method, I get a method-not-found error. Basically, I spawn a new thread from the main thread and try to change some UI properties (basically update a progress-bar) from the new thread using the following code: updateStatusDelegate usd = new updateStatusDelegate(progressBar.SetValue); Dispatcher.Invoke(usd, System.Windows.Threading.DispatcherPriority.Background, new object[] { System.Windows.Controls.ProgressBar.ValueProperty, Convert.ToDouble(perc) }); Can someone help me understand why do I encounter this error in .NET 3.0 version? I am able to get this going in .NET 3.0 SP2. But I guess .NET is not distributed independantly and is packaged only with .NET 3.5 version. My goal is to get away with the dependancy of .net 3.5 and have a dependancy on .NET 3.0 version Any help would be appreciated. Thanks Kapil

    Read the article

  • Bad disk performance on HP DL360 with Smarty Array P400i RAID controller

    - by sarge
    I have a HP DL360 server with 4x 146GB SAS disks and a Smart Array P400i RAID controller with 256MB cache. The disks are in RAID 5 (3 disks + 1 hot spare). The server is running VMware ESX 3i. The disk write performance is really bad. Here are some numbers: ns1:~# hdparm -tT /dev/sda /dev/sda: Timing cached reads: 3364 MB in 2.00 seconds = 1685.69 MB/sec Timing buffered disk reads: 18 MB in 3.79 seconds = 4.75 MB/sec ns1:~# time sh -c "dd if=/dev/zero of=ddfile bs=8k count=125000 && sync" 125000+0 records in 125000+0 records out 1024000000 bytes (1.0 GB) copied, 282.307 s, 3.6 MB/s real 4m52.003s user 0m2.160s sys 3m10.796s Compared to another server those number are terrible: Dell R200, 2x 500GB SATA disks, PERC raid controller (disks are mirrored). web4:~# hdparm -tT /dev/sda /dev/sda: Timing cached reads: 6584 MB in 2.00 seconds = 3297.79 MB/sec Timing buffered disk reads: 316 MB in 3.02 seconds = 104.79 MB/sec web4:~# time sh -c "dd if=/dev/zero of=ddfile bs=8k count=125000 && sync" 125000+0 records in 125000+0 records out 1024000000 bytes (1.0 GB) copied, 35.2919 s, 29.0 MB/s real 0m36.570s user 0m0.476s sys 0m32.298s The server isn't very loaded and the VMware Infrastructure Client performance monitor is showing 550KBps average read and 1208KBps average write for the last 30 minutes (highest write rate: 6.6MBps). This has been a problem from the start. Any ideas?

    Read the article

  • Will this increase my Virtual private Server failing rate ?

    - by Spencer Lim
    Will this increase my Virtual private Server failing rate if i :- install Microsoft Window Server 2008 Enterprise install SQL server enterprise 2008 install IIS 7.5 install ASP.Net Mvc 2 install Microsoft Exchange << should live inside MWS2008 ? or standalone without OS? install Team foundation server << should live inside MWS2008 ? or standalone without OS? on one mini VPS with specification of DELL Poweredge R710 shared plan DDR3 ECC RAMs 16GB and -- 1GB for this VPS using DELL PERC 6i raid controller (this thing alone about 1.5k-2k) and the SAS HDD (15K RPM) (146GB) -- 33GB to this VPS each hdd is freaking fast over 300MB read / write possible with proper tuning the motherboard is a DELL and it has twin redundant PSU (870watt 85%eff) its running on Intel Xeon 5502 (Quad Core) x2 so about 8 physical proc (fairly share) is there any ruler to measure for this about one VPS can only install what what what service ? because of my resource is limited =.@ may i know if it is install in this way,maybe it seem like defeat the way of "VPS"... what will happen ? or any guideline on this issue (fully configuring the window server 2008 R2) ? Thx for reply

    Read the article

  • restoring a failed SBS 2000 box...

    - by Brad Pears
    Hi there, I read a post where you had mentioned you have had a PERC card blow up on you in an SBS box... I've got a similar situation where one of my RAID drives failed and then the power supply failed before I could replace the drive... I then replaced the power supply and the failed drive and reconfigured the RAID array. I had a recent full backup of the my Win2k SBS's C: drive stored on my SYmantec backup exec server so I installed win2K server on the c: partition and then once I had that up and running, installed the backup exec agent so as to do a restore of the entire c drive including system state. THis all worked just fine, until I had to reboot. I received an "incorrect drive configuration" error and then it hangs. I figure that likely makes sense becasue I think my RAID array is configured slightly different now in that the partitions may be sizeded ever so slightly differently now than they were before I think... Is there a way I can just restore from my backup BUT maybe exclude some of the registry and hidden boot files it wants to restore so that it is booting with the current configuration now active on that machine - not the pre blow up configuration files? I also read a post that indicated you might have to install the exact same service pack etc... etc.. before attemting a restore but that does not make sense to me being as the entire c drive contents are going to be overwritten by the restore anyway? THe basic OS install is just to be able to get the backup exec agent installed . I can;t understand why one would need to install the exact same SP level. CAn you shed some light on what I might be able to do to get this thing up and running? Thanks,Brad

    Read the article

  • How to configure SCSI hard drives and RAID for Poweredge 2850 web server

    - by Saul
    I'm trying to set up a Poweredge 2850 as a web server, but as a server novice it's causing me some confusion. Its a virgin install so no data to be lost as yet, so I'd like to get the best arrangement for setting up Windows Server 2008. The box will run IIS, a mail and FTP server. The current physical arrangement of the hot swap drives is 1 73GB 3 146GB 5 blank 0 73GB 2 146GB 4 146GB (but flashes green, amber off) When I enter the PERC config screens on boot up I've got Raid Ch- 0 ID 0 ONLIN A00-00 1 ONLIN A00-01 2 ONLIN A01-00 3 ONLIN A01-01 4 HOTSP I think that drives 0 and 1 are set to RAID 1 and drives 2 and 3 are also set to RAID 1, certainly I can see 2 logical drives, both raid 1 of 69880MB and 139900MB Now what I think I am getting here is that the 2 73GB drives mirror each other and the 2 146GB drives mirror 2? so by my noob thinking if a drive fails I can pull it, insert and new one and it will reduplicate from its matching pair? I think the flashing amber probably indicates a failing drive in slot 4, should that just be binned? What confuses me coming from a home user XP background is that when I load up Windows Server 2008 OS under my computer I only see a C drive of about 70GB capacity. i.e wheres the 146GB drive? Any advice appreciated

    Read the article

  • ESX 4.0 space: DASD, NAS, or ?

    - by thormj
    I put together an ESX box for better management, but its performance is a WTF item; I'm a noob at dealing with ESX, so I'm looking for a laundry-list of reading material to help me straighten this out so I can go back to .NET programming. Current storage system: We're running Raid5+Hotspare (8x500 GB spindles) on a PERC6i on a Dell 2910. Due to ESX limitatios, the PERC is showing the storage as 1x2TB + 1x800GB "partitions." I'm not sure of the setup's configuration (stride / stripe / ???) at all. Our Applications We have a SBS server as well as a minor (2x50 GB, but growing at 10GB/month) database server... Our application that lives on the database VM is CPU and I/O insense; it's a database churning excercise mixed in with a lot of computation on the data (fixing that performance is what I'm supposed to be working on)... Perfomance Issue When I do a backup, restore, or worse (copy a backup from 1 vm to another to move it to the QA VM), the entire system slows to a crawl (even "unrelated" VMs). I originally thought a DASD situation would be quite good since you had PCI-x bandwidth, but the systemwide slowdown is killing productivity. Questions What should I do to make an intelligent decision about NAS vs RAID vs SAN vs DASD? Are there sweet spots/ugly spots in the storage setup? Can you use a SSD PCI-X card in ESX for the tempdb? Good/Bad idea? Is there any way to "share" some image in a copy-on-write fashion? Most of the "Backup-Copy-Restore" is to "put a clean image on the dev boxes"; if I could have them "share" the master image, the "big copy" (2x50 GB) would only need to be done once per week instead of once per dev per week...[runtime performance isn't a concern with the dev boxes, but the backup/copy/restore kills production, SBS, and everything else on the box]

    Read the article

  • Linux - real-world hardware RAID controller tuning (scsi and cciss)

    - by ewwhite
    Most of the Linux systems I manage feature hardware RAID controllers (mostly HP Smart Array). They're all running RHEL or CentOS. I'm looking for real-world tunables to help optimize performance for setups that incorporate hardware RAID controllers with SAS disks (Smart Array, Perc, LSI, etc.) and battery-backed or flash-backed cache. Assume RAID 1+0 and multiple spindles (4+ disks). I spend a considerable amount of time tuning Linux network settings for low-latency and financial trading applications. But many of those options are well-documented (changing send/receive buffers, modifying TCP window settings, etc.). What are engineers doing on the storage side? Historically, I've made changes to the I/O scheduling elevator, recently opting for the deadline and noop schedulers to improve performance within my applications. As RHEL versions have progressed, I've also noticed that the compiled-in defaults for SCSI and CCISS block devices have changed as well. This has had an impact on the recommended storage subsystem settings over time. However, it's been awhile since I've seen any clear recommendations. And I know that the OS defaults aren't optimal. For example, it seems that the default read-ahead buffer of 128kb is extremely small for a deployment on server-class hardware. The following articles explore the performance impact of changing read-ahead cache and nr_requests values on the block queues. http://zackreed.me/articles/54-hp-smart-array-p410-controller-tuning http://www.overclock.net/t/515068/tuning-a-hp-smart-array-p400-with-linux-why-tuning-really-matters http://yoshinorimatsunobu.blogspot.com/2009/04/linux-io-scheduler-queue-size-and.html For example, these are suggested changes for an HP Smart Array RAID controller: echo "noop" > /sys/block/cciss\!c0d0/queue/scheduler blockdev --setra 65536 /dev/cciss/c0d0 echo 512 > /sys/block/cciss\!c0d0/queue/nr_requests echo 2048 > /sys/block/cciss\!c0d0/queue/read_ahead_kb What else can be reliably tuned to improve storage performance? I'm specifically looking for sysctl and sysfs options in production scenarios.

    Read the article

  • Preventing h/w RAID cards from dropping slow JBOD disks

    - by Kevin
    I'm considering buying a used SAS h/w RAID card for externally attaching HDDs to an HP ProLiant I'm setting up. However, I only require RAID functionality on some of the drives. Theoretically it should be simple to JBOD the other drives, but some of them are inexpensive SATA disks and probably cannot have TLER disabled. I'd like to know, prior to actually ordering a RAID card, whether typically RAID cards would still enforce dropping of disks that do not respond within a few seconds, even if the disk is in a JBOD, and whether there is any way to disable this. Ideally it would be nice to be able to select certain SAS ports that will be pass-through, bypassing the RAID engine entirely and just acting as an HBA for those ports. I know I could buy a separate SAS HBA but that seems like a waste of $ and is also impractical as it's a 1U server so space is extremely limited. My question then is whether the functionality I'm looking for (pass-through on certain ports or at least JBOD drives not getting themselves dropped due to slow response) is typical of proper h/w RAID cards such as PERC 5/E etc. I've browsed through the latter's manual but unfortunately, as with most user manuals, it states the obvious and doesn't state the unobvious. Thanks for any info, Kevin

    Read the article

  • setup lowcost image storage server with 24x SSD array to get high IOPS?

    - by Nenad
    I want to build let's name it a lowcost Ra*san which would host for our social site the images (many millions) we have 5 sizes of every photo with 3 KB, 7 KB, 15 KB, 25 KB and 80 KB per Image. My idea is to build a Server with 24x consumer 240 GB SSD's in Raid 6 which will give me some 5 TB Disk space for the photo storage. To have HA I can add a 2nd one and use drdb. I'm looking to get above 150'000 IOPS (4K Random reads). As we mostly have read access only and rarely delete photos i think to go with consumer MLC SSD. I read many endurance reviews and don't see there a problem as long we don't rewrite the cells. What you think about my idea? - I'm not sure between Raid 6 or Raid 10 (more IOPS, cost SSD). - Is ext4 OK for the filesystem - Would you use 1 or 2 Raid controller, with Extender Backplane If anyone has realized something similar i would be happy to get Real World numbers. UPDATE I have buy 12 (plus some spare) OCZ Talos 480GB SAS SSD Drive's they will be placed in a 12-bay DAS and attached to a PERC H800 (1GB NV Cache, manufactured by LSI with fastpath) Controller, I plan to setup Raid 50 with ext4. If someone is wondering about some benchmarks let me know what you would like to see.

    Read the article

  • RAID 6 that can read with least 1000 Mbit/s?

    - by Diblo Dk
    I purchased a Dell PERC 6/i which I expected to be able to read with 1000 Mbps. There is not much to do now, but there are some things I wanted knowledge about for another time. I have configured it with four 2 TByte drives and RAID 6. It have 256 MByt ram and transfer rate of 300 Mbps. The benchmark test showed: Min read rate: 136.3 Mbps Max read rate: 329,6 Mbps Avg read rate: 242,2 Mbps What could I had done to get at least 1000 Mbps? Is it normal for internal and external RAID controllers to have a lower transfer rate eg. 300 Mbps? (I did not noticed at the time that it was not 3 Gbps) How would a RAID 10 had performed compared to RAID 6 or 5? Would it have been better to use software RAID (Linux) with the internal 3 Gbps SATA controller? UPDATE: The drives is SATA III 6 Gbps. http://www.seagate.com/files/staticfiles/docs/pdf/datasheet/disc/desktop-hdd-data-sheet-ds1770-1-1212us.pdf (2TB)

    Read the article

  • SQL Server: Network pauses after installing cheap SATA card: Is there a solution?

    - by samsmith
    At the risk of being assigned to the "bad DBA" club... I did something desperate, and may have to undo it. Problem: After installing a low cost eSATA board, my SQL Server is intermittently unresponsive (seemingly when there is a lot of IO to the eSATA drive). Questions: 1) Is there a solution to the intermittent unresponsiveness that allows me to keep the eSATA in place? 2) Whether or not (1==true): What is a decent, low cost way to add 1-3 TB storage to SQL for non-critical SQL DBs? Detail: Our SAN is full, and expanding it is costly and will take a month. I have a pressing need to add 1-3 TB for some development DBs (e.g. not mission critical; data loss is OK). As a bandaid, I threw a $20 eSATA PCI board in the Dell 1950 server, and attached an external 2TB eSATA drive. This seemed to work fine, but I notice that our production SQL DBs, and even remote desktop, now experience network "pauses" that they never did before (with both SQL client apps and remote desktop throwing "networking problem" errors). This SQL Server has lots of memory, and runs an instance of SQL 2005 (where all line of business apps reside) and an instance SQL 2008 (for development db's). SQL Server RAM has been appropriately configured, and this setup has run great for years. The server is: Dell 1950 Win2003 x64 14GB RAM PERC controller, 2 mirrored hd's internal Dell SAN over gbit ethernet, dual homed 2 PCIx slots (1 used by NIC for SAN, 1 now in use for eSATA board) Thank you for suggestions!

    Read the article

  • The enterprise vendor con - connecting SSD's using SATA 2 (3Gbits) thus limiting there performance

    - by tonyrogerson
    When comparing SSD against Hard drive performance it really makes me cross when folk think comparing an array of SSD running on 3GBits/sec to hard drives running on 6GBits/second is somehow valid. In a paper from DELL (http://www.dell.com/downloads/global/products/pvaul/en/PowerEdge-PowerVaultH800-CacheCade-final.pdf) on increasing database performance using the DELL PERC H800 with Solid State Drives they compare four SSD drives connected at 3Gbits/sec against ten 10Krpm drives connected at 6Gbits [Tony slaps forehead while shouting DOH!]. It is true in the case of hard drives it probably doesn’t make much difference 3Gbit or 6Gbit because SAS and SATA are both end to end protocols rather than shared bus architecture like SCSI, so the hard drive doesn’t share bandwidth and probably can’t get near the 600MiBytes/second throughput that 6Gbit gives unless you are doing contiguous reads, in my own tests on a single 15Krpm SAS disk using IOMeter (8 worker threads, queue depth of 16 with a stripe size of 64KiB, an 8KiB transfer size on a drive formatted with an allocation size of 8KiB for a 100% sequential read test) I only get 347MiBytes per second sustained throughput at an average latency of 2.87ms per IO equating to 44.5K IOps, ok, if that was 3GBits it would be less – around 280MiBytes per second, oh, but wait a minute [...fingers tap desk] You’ll struggle to find in the commodity space an SSD that doesn’t have the SATA 3 (6GBits) interface, SSD’s are fast not only low latency and high IOps but they also offer a very large sustained transfer rate, consider the OCZ Agility 3 it so happens that in my masters dissertation I did the same test but on a difference box, I got 374MiBytes per second at an average latency of 2.67ms per IO equating to 47.9K IOps – cost of an 240GB Agility 3 is £174.24 (http://www.scan.co.uk/products/240gb-ocz-agility-3-ssd-25-sata-6gb-s-sandforce-2281-read-525mb-s-write-500mb-s-85k-iops), but that same drive set in a box connected with SATA 2 (3Gbits) would only yield around 280MiBytes per second thus losing almost 100MiBytes per second throughput and a ton of IOps too. So why the hell are “enterprise” vendors still only connecting SSD’s at 3GBits? Well, my conspiracy states that they have no interest in you moving to SSD because they’ll lose so much money, the argument that they use SATA 2 doesn’t wash, SATA 3 has been out for some time now and all the commodity stuff you buy uses it now. Consider the cost, not in terms of price per GB but price per IOps, SSD absolutely thrash Hard Drives on that, it was true that the opposite was also true that Hard Drives thrashed SSD’s on price per GB, but is that true now, I’m not so sure – a 300GByte 2.5” 15Krpm SAS drive costs £329.76 ex VAT (http://www.scan.co.uk/products/300gb-seagate-st9300653ss-savvio-15k3-25-hdd-sas-6gb-s-15000rpm-64mb-cache-27ms) which equates to £1.09 per GB compared to a 480GB OCZ Agility 3 costing £422.10 ex VAT (http://www.scan.co.uk/products/480gb-ocz-agility-3-ssd-25-sata-6gb-s-sandforce-2281-read-525mb-s-write-410mb-s-30k-iops) which equates to £0.88 per GB. Ok, I compared an “enterprise” hard drive with a “commodity” SSD, ok, so things get a little more complicated here, most “enterprise” SSD’s are SLC and most commodity are MLC, SLC gives more performance and wear, I’ll talk about that another day. For now though, don’t get sucked in by vendor marketing, SATA 2 (3Gbit) just doesn’t cut it, SSD need 6Gbit to breath and even that SSD’s are pushing. Alas, SSD’s are connected using SATA so all the controllers I’ve seen thus far from HP and DELL only do SATA 2 – deliberate? Well, I’ll let you decide on that one.

    Read the article

  • MacGyver Moments

    - by Geoff N. Hiten
    Denny Cherry tagged me to write about my best MacGyver Moment.  Usually I ignore blogosphere fluff and just use this space to write what I think is important.  However, #MVP10 just ended and I have a stronger sense of community.  Besides, where else would I mention my second best Macgyver moment was making a BIOS jumper out of a soda can.  Aluminum is conductive and I didn't have any real jumpers lying around. My best moment is probably my entire home computer network.  Every system but one is hand-built, usually cobbled together out of spare parts and 'adapted' from its original purpose. My Primary Domain Controller is a Dell 2300.   The Service Tag indicates it was shipped to the original owner in 1999.  Box has a PERC/1 RAID controller.  I acquired this from a previous employer for $50.  It runs Windows Server 2003 Enterprise Edition.  Does DNS, DHCP, and RADIUS services as a bonus.  RADIUS authentication is used for VPN and Wireless access.  It is nice to sign in once and be done with it. The Secondary Domain Controller is an old desktop.  Dual P-III 933 with some extra drives. My VPN box is a P-II 250 with 384MB of RAM and a 21 GB hard drive.  I did a P-to-V to my Hyper-V box a year or so ago and retired the hardware again.  Dynamic DNS lets me connect no matter how often Comcast shuffles my IP. The Hyper-V box is a desktop system with 8GB RAM and an AMD Athlon 5000+ processor.  Cost me less than $500 to put together nearly two years ago.  I reasoned that if Vista and Windows 2008 were the same code then Vista 64-bit certified meant the drivers for Vista would load into Windows 2008.  Turns out I was right. Later I added three 1TB drives but wasn't too happy with how that turned out.  I recovered two of the drives yesterday and am building an iSCSI storage unit. (Much thanks to Starwind.  Great product).  I am using an old AMD 1.1GhZ box with 1.5 GB RAM (cobbled together from three old PCs) as my storave server.  The Hyper-V box is slated for an OS rebuild to 2008 R2 once I get the storage system worked out.  maybe in a week or two. A couple of DLink Gigabit switches ties everything together. Add in the Vonage box, the three PCs, the Wireless-N Access Point, the two notebooks and the XBox and you have gone from MacGyver to darn near Rube Goldberg. The only thing I really spend money on is power supplies and fans.  I buy top-of-the-line for both. I even pull and crimp my own cables. Oh, and if my kids hose up a PC, I have all of their data on a server elsewhere.  Every PC and laptop is pretty much interchangable for email and basic workstation tasks.  That helps a lot too. Of course I will tag SQLVariant.

    Read the article

  • I need help on this data file to be edited in SOM_PAK format

    - by Mola
    Hi Experts, I am working on Self Organizing Map (SOM) Implementation and i have a microarray dataset which i am trying to read in using some_read_data function, but i keep having an errors when i edit it to have it in SOM_PAK form which is recognise by SOM for reading such as ??? Error using == somtoolbox\som_read_data.m Only 69 vector components on input file data line 1 (dimension is 70) Error in == SomMainFunction at 3 sD = som_read_data('B_r2.txt'); but when i try to read the data without editing which is the original file as shown here: http://rapidshare.com/files/376239367/DLBCL.txt.html It indicates "Data read OK", but i have the following error ??? Error using == unknown Out of memory. Type HELP MEMORY for your options. Error in == somtoolbox\som_bmus.m at 189 Bmus = zeros(dlen,length(which_bmus)); Error in == somvis\somvis_p_matrix.m at 41 [dummy dists] = som_bmus (dat, dat, 2:datlen); Error in == SomMainFunction at 16 [pheight rad_real perc] = somvis_p_matrix(sM,sD); You can get the datafile from here:http://rapidshare.com/files/376239367/DLBCL.txt.html I need someone to help me correct this data for me and put it in SOM_PAK format. I have tried getting it in SOM_PAK format, but it still giving me errors:

    Read the article

  • Disk performance below expectations

    - by paulH
    this is a follow-up to a previous question that I asked (Two servers with inconsistent disk speed). I have a PowerEdge R510 server with a PERC H700 integrated RAID controller (call this Server B) that was built using eight disks with 3Gb/s bandwidth that I was comparing with an almost identical server (call this Server A) that was built using four disks with 6Gb/s bandwidth. Server A had much better I/O rates than Server B. Once I discovered the difference with the disks, I had Server A rebuilt with faster 6Gbps disks. Unfortunately this resulted in no increase in the performance of the disks. Expecting that there must be some other configuration difference between the servers, we took the 6Gbps disks out of Server A and put them in Server B. This also resulted in no increase in the performance of the disks. We now have two identical servers built, with the exception that one is built with six 6Gbps disks and the other with eight 3Gbps disks, and the I/O rates of the disks is pretty much identical. This suggests that there is some bottleneck other than the disks, but I cannot understand how Server B originally had better I/O that has subsequently been 'lost'. Comparative I/O information below, as measured by SQLIO. The same parameters were used for each test. It's not the actual numbers that are significant but rather the variations between systems. In each case D: is a 2 disk RAID 1 volume, and E: is a 4 disk RAID 10 volume (apart from the original Server A, where E: was a 2 disk RAID 0 volume). Server A (original setup with 6Gpbs disks) D: Read (MB/s) 63 MB/s D: Write (MB/s) 170 MB/s E: Read (MB/s) 68 MB/s E: Write (MB/s) 320 MB/s Server B (original setup with 3Gpbs disks) D: Read (MB/s) 52 MB/s D: Write (MB/s) 88 MB/s E: Read (MB/s) 112 MB/s E: Write (MB/s) 130 MB/s Server A (new setup with 3Gpbs disks) D: Read (MB/s) 55 MB/s D: Write (MB/s) 85 MB/s E: Read (MB/s) 67 MB/s E: Write (MB/s) 180 MB/s Server B (new setup with 6Gpbs disks) D: Read (MB/s) 61 MB/s D: Write (MB/s) 95 MB/s E: Read (MB/s) 69 MB/s E: Write (MB/s) 180 MB/s Can anybody suggest any ideas what is going on here? The drives in use are as follows: Dell Seagate F617N ST3300657SS 300GB 15K RPM SAS Dell Hitachi HUS156030VLS600 300GB 3.5 inch 15000rpm 6GB SAS Hitachi Hus153030vls300 300GB Server SAS Dell ST3146855SS Seagate 3.5 inch 146GB 15K SAS

    Read the article

  • MD3200 - 3 to 4x less throughput than MD1220. Am I missing something here?

    - by Igor Polishchuk
    I have two R710 servers with similar configuration. One in my office has MD1220 attached. Another one in the datacenter of my hosting services vendor has MD3200. I'm getting significantly worse throughput from MD3200 at my vendors setup. I'm mostly interested in sequential writes, and I'm getting these results in bonnie++ and dd tests: Seq. writes on MD1220 in my office: 1.1 GB/s - bonnie++, 1.3GB/s - dd Seq. writes on MD3200 at my vendor's: 240MB/s - bonnie++, 310MB/s - dd Unfortunately, I could not test the exactly the same configurations, but the two I have should be comparable. If anything, my good performing environment is cheaper than the bad performing. I expect at least similar throughput from these two setups. My vendor cannot really help me. Hopefully, somebody more familiar with the DAS performance can look at it and tell if I'm missing something here and my expectations are too high. To summarize, the question here is it reasonable to expect about 100MB/s of sequential write throughput per each couple of drives in RAID10 on MD3200? Is there any trick to enable such performance in MD3200 with dual controller as opposed to simple MD1220 with a single H800 adapter? More details about the configurations: A good one in my office: Dell R710 2CPU X5650 @ 2.67GHz 12 cores 96GB DDR3, OS: RHEL 5.5, kernel 2.6.18-194.26.1.el5 x86_64 20x300GB 2.5" SAS 10K in a single RAID10 1MB chunk size on MD1220 + Dell H800 I/O controller with 1GB cache in the host Not so good one at my vendor's: Dell R710 2CPU L5520 @ 2.27GHz 8 cores 144GB DDR3, OS: RHEL 5.5, kernel 2.6.18-194.11.4.el5 x86_64 20x146GB 2.5" SAS 15K in a single RAID10 512KB chunk size, Dell MD3200, 2 I/O controllers in array with 1GB cache each Additional information. I've also ran the same tests on the same vendor's host, but the storage was: two raids of 14x146GB 15K RPM drives RAID 10, striped together on the OS level on MD3000+MD1000. The performance was about 25% worse than on MD3200 despite having more drives. When I ran similar tests on the internal storage of my vendor's host (2x146GB 15K RPM drives RAID1, Perc 6i) I've got about 128MB/s seq. writes. Just two internal drives gave me about a half of 20 drives' throughput on MD3200. The random I/O performance of the MD3200 setup is ok, it gives me at least 1300 IOPS. I'm mostly have problems with sequentioal I/O throughput. Thank you for looking into it. Regards Igor

    Read the article

  • Windows 2003 Storage Server Hanging on Large File Transfers

    - by user25272
    In one of our offices we have a Dell PowerVault 745N NAS device which acts as the main file server. Its running 32bit Windows 2003 Storage Server SP2 with 3GB RAM. The server holds around 60 users HOME folders, which are mapped via AD. The office clients are a mix of XP SP3, Vista and Windows 7. Occasionally the server will completely hang when transferring large files. When the hang happens the console becomes unresponsive with only the mouse active and blank wallpaper. Sometimes stopping the copy frees the server, sometimes not. The hanging can last around 20 minutes. During this time other servers also become unresponsive with blank wallpaper at the console. If you do manage to get onto another server the taskbar and run commands are unresponsive. This also transcends to the client computers sometimes with explorer crashing. I'm guessing this is due to the HOME folder mapping. Eventually the NAS server with free up and everything will be back to normal. The server is configured as follows: PERC 4/DC DATA 2 - 12 SCSI HDD - RAID5 SHADOWCOPY 2 SCSI HDD - RAID1 CERC SATA DATA 11 4 SATA HDD - RAID5 OS 4 SATA HDD - RAID5 All the drivers and firmware is up to date. I've been through all the diagnostics with Dell and the hardware has come up clean including full HDD tests on the arrays. The server has NOD32 installed as the AV, but the hanging happens when it is uninstalled. There are no errors in the event log when this happens and we don't have any errors logged on any of our ProCurve switches. DNS is fine on the domain and AD from what I can tell is running happily. There are no DFS or NFS shares setup either. All the shares are standard Windows. I've unchecked the allow the computer to turn off this device to save power box under Power Management on the NIC. "Set Link Speed and Duplex to Auto-negotiate 1000 " Increased Receive Descriptors buffer from 256 to 352 (reserves more CPU resource for handling data) I've run network traces using network monitor and have found the following: 417 8.078125 {SMB:192, NbtSS:25, TCP:24, IPv4:23} 192.168.2.244 192.168.5.35 SMB SMB:R; Nt Create Andx - NT Status: System - Error, Code = (52) STATUS_OBJECT_NAME_NOT_FOUND I've tried different cabling; NICs and switch ports all with the same result. Transferring files from other servers on the domain is fine. All I haven't done is run CHKDSK on the drives to look for any file system errors. On the Vista clients I have also run netsh interface tcp set global autotuning=disabled with no result. Could it be that the server has a faulty drive or that the I/O is too much for it to handle? Any ideas why would the hang cause issues with the other servers on the LAN? Many Thanks.

    Read the article