Search Results

Search found 104 results on 5 pages for 'perc'.

Page 3/5 | < Previous Page | 1 2 3 4 5  | Next Page >

  • Linux Fiber Channel Host Setup Basic

    - by Jim
    I've been googling for about 4 hours now with no luck. I am trying to setup a Linux server running Oracle Server 6.3 as a Fiber Channel host. And then connect it to a Dell Compellent Fibre Channel Host contain a 500GB Volume. The Oracle server itself contains two Brocade 815 FC HBAs. I've discovered their WWN(I think) via cat /sys/class/fc_host/host1/port_name 0x100000051efc3d85 cat /sys/class/fc_host/host2/port_name 0x100000051efc3d9f The next part is where I am at a loss. I've used iSCSI before...is FC the same deal where you have an initiator and a target? If so where do I specific that in linux? I'm also new to Fiber Channel as a protocol, so i am unsure what is needed to make a transaction? WWN and port ID? Similar to IP:Port combination in the Ethernet world. I've read alot regarding using systool, multipath, fc_transport commands, however none of these is recognized as a valid command from Oracle Server 6.3 Appreciate the guidance and assistance. I installed sccsi-target-utils and can now run rescan-scsi-bus and sg_map -x. rescan-scsi-bus.sh -l -w -r Host adapter 0 (megaraid_sas) found. Host adapter 1 ((null)) found. Host adapter 2 ((null)) found. Host adapter 3 (ata_piix) found. Host adapter 4 (ata_piix) found. Scanning SCSI subsystem for new devices and remove devices that have disappeared Scanning host 0 for SCSI target IDs 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15, LUNs 0 1 2 3 4 5 6 7 Scanning for device 0 2 0 0 .... OLD: Host: scsi0 Channel: 02 Id: 00 Lun: 00 Vendor: DELL Model: PERC H700 Rev: 2.30 Type: Direct-Access ANSI SCSI revision: 05 Scanning for device 0 2 1 0 ... OLD: Host: scsi0 Channel: 02 Id: 01 Lun: 00 Vendor: DELL Model: PERC H700 Rev: 2.30 Type: Direct-Access ANSI SCSI revision: 05 Scanning host 1 for all SCSI target IDs, LUNs 0 1 2 3 4 5 6 7 Scanning for device 1 0 3 1 ... OLD: Host: scsi1 Channel: 00 Id: 03 Lun: 01 Vendor: COMPELNT Model: Compellent Vol Rev: 0505 Type: Direct-Access ANSI SCSI revision: 05 Scanning host 2 for all SCSI target IDs, LUNs 0 1 2 3 4 5 6 7 Scanning host 3 for all SCSI target IDs, LUNs 0 1 2 3 4 5 6 7 Scanning for device 3 0 0 0 ... REM: Host: scsi3 Channel: 00 Id: 00 Lun: 00 DEL: Vendor: TEAC Model: DVD-ROM DV-28SW Rev: R.2A Type: CD-ROM ANSI SCSI revision: 05 Scanning host 4 channels 0 for SCSI target IDs 0, LUNs 0 1 2 3 4 5 6 7 0 new device(s) found. 1 device(s) removed. and sg_map -x /dev/sg0 0 0 32 0 13 /dev/sg1 0 2 0 0 0 /dev/sda /dev/sg2 0 2 1 0 0 /dev/sdb /dev/sg4 1 0 3 1 0 /dev/sdc I'm not sure what this all means...

    Read the article

  • perf tuning for ESX vmfs3 on RAID

    - by maruti
    looking for recommendations on ESX4 OS - VMFS version3: RAID-5 : matching the stripe size with VMFS block size? (64K, 128K etc) RAID controller options: "adaptive read ahead, write-back" on PERC 6i 90% VMs on server are Windows (2008, 2003, Vista etc, SQL 2005 etc) i have read that smaller stipes are good for writes and larger for reads. Since this is virtual env, not sure whats good.

    Read the article

  • perf tuning for vmfs3 on RAID

    - by maruti
    recommendations for ESX4 OS - VMFS version3: matching: RAID-5 stripe size with VMFS block size? (64K, 128K etc) enabled "adaptive read ahead, write-back" on PERC 6i 90% VMs on server are Windows (2008, 2003, Vista etc, SQL 2005 etc) i have read that smaller stipes are good for writes and larger for reads. Since this is virtual env, not sure whats good.

    Read the article

  • Slow Write Speed on ESXi host

    - by Gregg Leventhal
    I have an ESXi 5.0 free host with an internal datastore of 7.2K 5 disk RAID 5 using a PERC 710 mini RAID controller in a Dell Poweredge R620 Server with 32GB Ram and a 12 Core Xeon. I seem to get slow write speeds in the guests so I checked out ESXTOP and I see 15MB/s write speed there on this host, which is comprable to the guests. What could be causing such horrible write speeds? Is RAID 5 really this slow to write??

    Read the article

  • How to figure out disks performance in Xen?

    - by cpt.Buggy
    So, I have a Dell R710 with PERC 6/i Integrated and 6 450Gb Seagate 15k SAS disks in RAID10, I have 30 Xen vps working on it. Now I need to deploy second server with same hardware for same tasks and I want to figure out maybe it's a good idea to use RAID5 instead of RAID10 because we have a lot of "free" memory on first server and not so much "free space". How do I find out disks performance on first server and find out could I move it to RAID5 without slowing down of whole system?

    Read the article

  • recommendation for java VM running on embedded system

    - by pierr
    Hi, We are trying to support Java enviroment on our embedded platform (700MHZ MIPS74K, 128-256M memory).After reading this article and googling a bit, I come up with the shorted list: Sun Java SE for embedded Kaffe Jbed Perc HP Chai VM PhoneME I was quite new to Java and its Runtime enviroment. Your suggestion is greatly appreciated.

    Read the article

  • Transparant pixels in a TPngimage object

    - by John Duinmeijer
    Is there anybody who can help me making pixels of an png picture transparant, such like: MakePixelTransparant(const png:TPngImage; x,y:integer; perc:integer); and what else do I have to do to makes thinks works (with values do i have to change to make the png object transparant, so i can use it in for example PhotoShop). Thanks, John Duinmeijer.

    Read the article

  • Setup access to SAS RAID drives with NTFS partitions on CentOS Machine

    - by Quanano
    We have a Dell Poweredge 2900 system with Adaptec 39320A SCSI CONTROLLER CARD and 4 SAS hard drives attached, with NTFS partitions on them. We installed CentOS on the other raid array with a different controller and it is working fine. We are now trying to access the drives shown above and they are not being shown in /dev as sdb, etc. sda is the drive that we installed centos on and it has sda1, sda2, sda3, etc. The CDROM has been picked up as well. If I scan for scsi devices then the perc and adaptec controllers are both found. sg0 is the CDROM and sg2 is the centos installed, however I think sg1 is the other drive but I cannot see anyway to mount the partitions, as only the drive is listed in /dev. Thanks. EXTRA INFO fdisk -l Disk /dev/sda: 72.7 GB, 72746008576 bytes 255 heads, 63 sectors/track, 8844 cylinders Units = cylinders of 16065 * 512 = 8225280 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x11e3119f Device Boot Start End Blocks Id System /dev/sda1 * 1 64 512000 83 Linux Partition 1 does not end on cylinder boundary. /dev/sda2 64 8845 70528000 8e Linux LVM Disk /dev/mapper/vg_lal2server-lv_root: 34.4 GB, 34431041536 bytes 255 heads, 63 sectors/track, 4186 cylinders Units = cylinders of 16065 * 512 = 8225280 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x00000000 Disk /dev/mapper/vg_lal2server-lv_root doesn't contain a valid partition table Disk /dev/mapper/vg_lal2server-lv_swap: 21.1 GB, 21139292160 bytes 255 heads, 63 sectors/track, 2570 cylinders Units = cylinders of 16065 * 512 = 8225280 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x00000000 Disk /dev/mapper/vg_lal2server-lv_swap doesn't contain a valid partition table Disk /dev/mapper/vg_lal2server-lv_home: 16.6 GB, 16647192576 bytes 255 heads, 63 sectors/track, 2023 cylinders Units = cylinders of 16065 * 512 = 8225280 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x00000000 Disk /dev/mapper/vg_lal2server-lv_home doesn't contain a valid partition table These are all from the install hdd not the additional hard drives modprobe a320raid FATAL: Module a320raid not found. lsscsi -v [0:0:0:0] cd/dvd TSSTcorp CDRWDVD TS-H492C DE02 /dev/sr0 dir: /sys/bus/scsi/devices/0:0:0:0 [/sys/devices/pci0000:00/0000:00:1f.1/host0/target0:0:0/0:0:0:0] [4:0:10:0] enclosu DP BACKPLANE 1.05 - dir: /sys/bus/scsi/devices/4:0:10:0 [/sys/devices/pci0000:00/0000:00:05.0/0000:01:00.0/0000:02:0e.0/host4/target4:0:10/4:0:10:0] [4:2:0:0] disk DELL PERC 5/i 1.03 /dev/sda dir: /sys/bus/scsi/devices/4:2:0:0 [/sys/devices/pci0000:00/0000:00:05.0/0000:01:00.0/0000:02:0e.0/host4/target4:2:0/4:2:0:0] . lsmod Module Size Used by fuse 66285 0 des_generic 16604 0 ecb 2209 0 md4 3461 0 nls_utf8 1455 0 cifs 278370 0 autofs4 26888 4 ipt_REJECT 2383 0 ip6t_REJECT 4628 2 nf_conntrack_ipv6 8748 2 nf_defrag_ipv6 12182 1 nf_conntrack_ipv6 xt_state 1492 2 nf_conntrack 79453 2 nf_conntrack_ipv6,xt_state ip6table_filter 2889 1 ip6_tables 19458 1 ip6table_filter ipv6 322029 31 ip6t_REJECT,nf_conntrack_ipv6,nf_defrag_ipv6 bnx2 79618 0 ses 6859 0 enclosure 8395 1 ses dcdbas 9219 0 serio_raw 4818 0 sg 30124 0 iTCO_wdt 13662 0 iTCO_vendor_support 3088 1 iTCO_wdt i5000_edac 8867 0 edac_core 46773 3 i5000_edac i5k_amb 5105 0 shpchp 33482 0 ext4 364410 3 mbcache 8144 1 ext4 jbd2 88738 1 ext4 sd_mod 39488 3 crc_t10dif 1541 1 sd_mod sr_mod 16228 0 cdrom 39771 1 sr_mod megaraid_sas 77090 2 aic79xx 129492 0 scsi_transport_spi 26151 1 aic79xx pata_acpi 3701 0 ata_generic 3837 0 ata_piix 22846 0 radeon 1023359 1 ttm 70328 1 radeon drm_kms_helper 33236 1 radeon drm 230675 3 radeon,ttm,drm_kms_helper i2c_algo_bit 5762 1 radeon i2c_core 31276 4 radeon,drm_kms_helper,drm,i2c_algo_bit dm_mirror 14101 0 dm_region_hash 12170 1 dm_mirror dm_log 10122 2 dm_mirror,dm_region_hash dm_mod 81500 11 dm_mirror,dm_log

    Read the article

  • Dell PowerEdge R410: System asks to press F1 or F2

    - by hurikhan77
    We just installed an option card (PERC 6/i) into a brand-new Dell PowerEdge R410 and now the system does no unattended startup but instead asks me to press F1 to continue or F2 to enter system setup after printing the following message on the console: Fan 4 speed may change depending on system configuration and option card install. How do I make the system ignore this "problem" or whatever that is? This system is going to be installed at a remote data center and needs to be able to restart unattended. I do not want to ignore errors completely to not get endless restart loops in case of errors.

    Read the article

  • What would be the optimal disk config for SQL Server 2008 R2?

    - by Kev
    We have a new Dell R710 server that came with the following storage configuration: 8 x 146GB SAS 10k 6Gbps disks 1 x Perc H700 Integrated Controller (2 x 4 disks - 2 ports each supporting 4 disks) What would be the optimal configuration if we were just after performance? What would be the optimal configuration if we were after performance but wanted data resilience. As per 2 above but with a hot standby disk? We plan to run Windows 2008 R2 and SQL Server 2008 R2. Maximising storage capacity isn't a prime concern.

    Read the article

  • Windows-Server-2003 setup on Dell-PowerEdge R310 is hanging [closed]

    - by Robert Rose
    Possible Duplicate: Problems installing OS on Dell PowerEdge R410 I am trying to configure a Dell PowerEdge R310 server with Windows Server 2003. I've already configured the two hard drives as RAID1. The HD controller is PERC H700 Integrated and Adapter. Trying to stay with Windows Server 2003 on this fairly new server to save on cost and keep the configuration the same as my old server, which has been running like a champ for five years. Problem: During the OS installation, after everything has been copied from the installation CD, the installation hangs at a window labeled 'Windows Setup' with the message 'Setup is starting Windows' at the bottom. I'm wondering if this is a driver problem and if so, where can I get the drivers for the R310 or where can I get the media for the latest version of Windows Server 2003 which may include the necessary drivers? Will certainly appreciate some help here.

    Read the article

  • ZFS SAS/SATA controller recommendations

    - by ewwhite
    I've been working with OpenSolaris and ZFS for 6 months, primarily on a Sun Fire x4540 and standard Dell and HP hardware. One downside to standard Perc and HP Smart Array controllers is that they do not have a true "passthrough" JBOD mode to present individual disks to ZFS. One can configure multiple RAID 0 arrays and get them working in ZFS, but it impacts hotswap capabilities (thus requiring a reboot upon disk failure/replacement). I'm curious as to what SAS/SATA controllers are recommended for home-brewed ZFS storage solutions. In addition, what effect does battery-backed write cache (BBWC) have in ZFS storage?

    Read the article

  • Defragment an Exchange Volume

    - by IceMage
    The Scenario: I use a dedicated volume (RAID volume) to store all of my data for my Exchange 2007 server. Today, out of curiosity, I decided to check up on how fragmented the files on this data volume were. To my surprise, the answer is extremely. So, a three part question: First and Foremost, SHOULD I defragment this volume (after a full backup of course)? Be specific as to why not if I should not, or reasons I absolutely should if I should. Second, about how much time should I allow for during this maintenance period per gigabyte. The drives are all 7200 RPM SATA drives on a Hardware RAID 5 controller (Perc 5i/6i, can't remember), the files are extremely fragmented. (Over 5000 file fragments per gigabyte). Third, is there something wrong here? It seems to me like the drive shouldn't be this fragmented. Could something be configured incorrectly that could be causing this to happen?

    Read the article

  • Reduce the I/O priority of Windows Backup (Windows Server 2008 R2)

    - by HelloSam
    I have a PostgreSQL running on Windows Server 2008 R2 x64 box. And I have scheduled a backup everyday from the RAID 1 DB disk to a dedicated standalone disk. They are SAS 15k on Dell PERC 6i. I am using the built-in Windows Server Backup for purpose. The problem is, whenever the backup process is kicked in, the database performance is hogged. I would say almost a 10x of performance reduction. From the resource monitor, the disk queue is in the double digit range when backing up, and less than 1 during the day. The disk activity is like ~30-50MB/s during backup, so I guess the hardware is acting normally, though wbengine.exe takes up most of the portions. I think reduce the IO priority of the backup process would be an answer, but I couldn't find a way to. Tuning process CPU priority does not seems to help.

    Read the article

  • What does Embedded SATA Controller : ATA mean?

    - by paulH
    I have a Poweredge R510 server with a PERC H700 Integrated RAID controller that is exhibiting slower than expected disk speeds (RAID 1 and RAID 10 arrays) and I'm looking at the configuration of the server. Running the command omreport chassis biossetup on the server shows me the following configuration setting: Embedded SATA Controller : ATA I can also see that the possible options for this setting are: off | ata | qdma | raid I've been looking online to find out what this setting means and what the various options refer to but I've been unable to find anything particularly helpful, so I was hoping that somebody here could help to enlighten me. Thanks, Paul.

    Read the article

  • Best SQL Server Configuration with this hardware.

    - by DavidStein
    I just received my new SQL Server from Dell. The server will be serve approximately 15 OLTP databases which average 10GB in size. Here are the basic specs: Dell PowerEdge R510 with up to 12 Hot Swap HDDs,LED Intel Xeon E5649 2.53GHz, 12M Cache, 5.86 GT/s QPI, 6 core (Quantity of 2) 48GB Memory (6x8GB), 1333MHz Dual Ranked RDIMMs for 2 Processors, Optimized PERC H700 Integrated RAID Controller, 1GB NV Cache 300GB 15K RPM SA SCSI 6Gbps 3.5in Hotplug Hard Drive (Quantity of 4) 600GB 15K RPM SA SCSI 6Gbps 3.5in Hotplug Hard Drive (Quantity of 6) My first thought was to use 3 arrays. OS - Raid 1 - (2)300GB T-Log - Raid 1 (2)300GB DB - Raid 5 (5) 600GB Backup - (1) 600GB - non-raided. However, I could also do the following after purchasing one more drive for backup. OS and T-Log - Raid 10 - (4)300GB DB - Raid 10 (6)600GB The hard drive space is not an issue as the databases are not that large. I'm just trying to optimize the speed of the applications using these databases. So, what would you guys recommend?

    Read the article

  • What software can I use to pinpoint why Windows Server 2003 takes 15 seconds for any operation?

    - by Dr. Zim
    Ram is about 1/2 in use, four CPUs are all but idle. I tried "Microsoft Server Performance Advisor" with no luck. No entries in the Event Log for hardware failures, etc. And yet I can click on the start menu and wait 15 seconds for any new attempt. Launching software takes 30 seconds to respond. The server has an 8 drive WD RE 250 gig each Dell Perc 6 Sata raid array with Intel gigabit network cards. Anyone have any software titles that could analyze what is going wrong with this server?

    Read the article

  • Will this increase my VPS failing rate ?

    - by Spencer Lim
    Will this increase my Virtual private Server failing rate if i :- install Microsoft Window Server 2008 Enterprise install SQL server enterprise 2008 install IIS 7.5 install ASP.Net Mvc 2 install Microsoft Exchange install Team foundation server on one mini VPS with specification of DELL Poweredge R710 shared plan DDR3 ECC RAMs 16GB and -- 1GB for this VPS using DELL PERC 6i raid controller (this thing alone about 1.5k-2k) and the SAS HDD (15K RPM) (146GB) -- 33GB to this VPS each hdd is freaking fast over 300MB read / write possible with proper tuning the motherboard is a DELL and it has twin redundant PSU (870watt 85%eff) its running on Intel Xeon 5502 (Quad Core) x2 so about 8 physical proc (fairly share) is there any ruler for this about one VPS can only install what what what service ? Thx for reply

    Read the article

  • How to set up Dell OMSA tools on Debian 6 (Squeeze) (PE2950)

    - by javano
    I assume I have set up them up incorrectly or am missing a library or dependency. When I log into the OMSA web interface I can't see anything Also, omreport tells me nothing; root@box:~# omreport storage controller No controllers found I assume these two will use the same source of information so what ever is wrong will fix them both. I set up OMSA as per these instructions. Also I have compiled MegaCLI (as this is a PowerEdge 2950 with a Perc 6/i controller) and I have used that to update the RAID firmware, so that works, but the Dell tools aren't. What have I missed during set up? root@kvm1:~# cat /etc/issue Debian GNU/Linux 6.0 \n \l root@kvm1:~# uname -a Linux kvm1.mivoice.cust.vostron.net 3.4.9 #1 SMP Wed Aug 22 19:08:46 BST 2012 x86_64 GNU/Linux

    Read the article

  • Using a non-validated SED on a Dell R720

    - by a coder
    We were given a Dell R720 a couple years ago, and the machine currently has standard 300GB 3.5" SAS 15k drives. Our RAID controller is a Perc H710. We need to update our disks to FIPS 140-2 certified SED. According to Dell, they have only one tested/validated FIPS SED for this machine/controller, but it is a 7200rpm 3.5" unit. I'm showing that Dell offers a 600GB 15k FIPS SED in 3.5" configuration (Dell part number 342-0605), but they say they haven't validated or tested to know if it works. They informed us that we would not void our warranty in using this non-validated drive. How likely is it that our R720 with H710 controller will work with the non-validated drive? Are there significant differences in how drive manufacturers build SED that would prevent them from working consistently across different controllers?

    Read the article

  • RAID 10: SPAN 2 vs SPAN 4

    - by LaDante Riley
    I am currently configuring RAID 10 (first time doing RAID ever) for a server at work. In the Configuration Utility. I am given the option of either span 2 or span 4. Having never done this before, I was curious if someone could tell me the pros and cons of for each span? Thanks The server is a Poweredge r620 with a PERC H710 mini (Security Capable) RAID controller. I have 8 600GB hard drives. I am creating this server as a network storage drive. I have SQL server historian database whose 1TB storage filled up and after 5 years of logging data.

    Read the article

  • Removing RAID on a DELL power-edge server

    - by Simon Callan
    We have a Dell Power-edge T110 server, with either a PERC S100 or S300 raid controller (I suspect S100), and 2 x 500GB SATA hard discs. These discs are running in RAID-1 configuration, (either 1 or 2 virtual discs), and on top of this, we have the C and D drives. As we are running low on disc space, we are looking at dropping the RAID to get some disc space back. Is it possible to split the discs back into 2 seperate hards discs that the OS can see, without losing all the data on the drives? Even better, would it be possible to split the D: drive, leaving the OS C: drive in RAID1 configuration?

    Read the article

  • Should I disable write caching on my Windows 2008 VM?

    - by javano
    I have a Windows Server 2008 x64 Standard virtual machine that runs on a machine with a hardware RAID controller, a Perc 6/i, which has a battery on-board. Doing everything I can for additional performance, I think I should disable this. Is this very dangerous though? My understand is that Battery Backed Write Caching gives a performance boost to the host OS, telling it the write was complete when they are still sitting in flash waiting to be written. However, I can't see how it would be detrimental to performance, but is there a gain (even if marginal) to enabling it / disabling it? P.s. There machine has a backup power. Here is a screen shot for clarification:

    Read the article

  • Installing W2K8 R2 on a Dell Poweredge 2850

    - by DerekT
    I'm a server novice and have been given a Dell 2850 (PERC 4e/Di). It has 3 blank HDs that I think are configured as RAID 5. I am trying to install W2K8 R2 SP1 on it. It doesn't have a DVD reader so I created an install USB. This works fine until it's time to copy files to the HD. It can't see a HD. There is an option to browse for drivers at this stage. Any idea what drivers I need and where to download them? I downloaded this driver RAID_DRVR_WIN_R227150.EXE but this failed with invalid signature. Thanks to dyasny for the link to LSI-LOGIC_MULTI-DEVICE_A00_R227150.exe.

    Read the article

< Previous Page | 1 2 3 4 5  | Next Page >