Search Results

Search found 3192 results on 128 pages for 'dell precision'.

Page 42/128 | < Previous Page | 38 39 40 41 42 43 44 45 46 47 48 49  | Next Page >

  • Printing from web pages (reports especially) with greater precision.

    - by Kabeer
    Hello. I am re-engineering a windows application to be ported to web. One area that has been worrying is 'printing'. The application is data intensive and complex reports need to be generated. The erstwhile windows application takes advantage of printer APIs and extends sophisticated control to the users. It supports functions like page break, avoiding printing on printed parts of the sheet (like letterhead), choice of layouts and orientation, etc. Please note that these setting are not done only while printing, they are part of report definition sometimes. From what I know, we cannot have this kind of control while printing web pages. I am in a process of identifying options at my disposal. While I prefer to first look into something that will help me print from raw web pages, following are other thoughts: Since reports can also be exported to .xls & .pdf versions, let user download one and print directly. This however limits my solution to the area of application that have export feature. Use Silverlight (4.0) for report layout definition and print. I think Silverlight 4.0 (in beta right now) provides adequate control over the printer. I have so far been avoiding the need of any RIA plugin. Meticulously generate reports on web with fixed dimensions. I am not sure how far this will go. Please share practices that can be applied easily in my scenario.

    Read the article

  • compact Number formatting behavior in Java (automatically switch between decimal and scientific notation)

    - by kostmo
    I am looking for a way to format a floating point number dynamically in either standard decimal format or scientific notation, depending on the value of the number. For moderate magnitudes, the number should be formatted as a decimal with trailing zeros suppressed. If the floating point number is equal to an integral value, the decimal point should also be suppressed. For extreme magnitudes (very small or very large), the number should be expressed in scientific notation. Alternately stated, if the number of characters in the expression as standard decimal notation exceeds a certain threshold, switch to scientific notation. I should have control over the maximum number of digits of precision, but I don't want trailing zeros appended to express the minimum precision; all trailing zeros should be suppressed. Basically, it should optimize for compactness and readability. 2.80000 - 2.8 765.000000 - 765 0.0073943162953 - 0.00739432 (limit digits of precision—to 6 in this case) 0.0000073943162953 - 7.39432E-6 (switch to scientific notation if the magnitude is small enough—less than 1E-5 in this case) 7394316295300000 - 7.39432E+6 (switch to scientific notation if the magnitude is large enough—for example, when greater than 1E+10) 0.0000073900000000 - 7.39E-6 (strip trailing zeros from significand in scientific notation) 0.000007299998344 - 7.3E-6 (rounding from the 6-digit precision limit causes this number to have trailing zeros which are stripped) Here's what I've found so far: The .toString() method of the Number class does most of what I want, except it doesn't upconvert to integer representation when possible, and it will not express large integral magnitudes in scientific notation. Also, I'm not sure how to adjust the precision. The "%G" format string to the String.format(...) function allows me to express numbers in scientific notation with adjustable precision, but does not strip trailing zeros. I'm wondering if there's already some library function out there that meets these criteria. I guess the only stumbling block for writing this myself is having to strip the trailing zeros from the significand in scientific notation produced by %G.

    Read the article

  • Need events to execute on timer events, metronome precision.

    - by user295734
    I setup a timer to call an event in my application. The problme is the event execution is being skewed by other windows operations. Ex. openning and window, loading a webpage. I need the event to excute exactly on time, every time. When i first set up the app, used a sound file, like a metronome to listen to the even firing, in a steady state, its firing right on, but as soon do something in the windows environment, the sound fires slower, then sort of sppeds up a bit to catch up. So i added a logging method to the event to ctahc the timer ticks. From that data, it appears that the timer is not being affected by the windows app, but my application event calls are being affected. I figured this out by checking the datetime.now in the event, and if i set it to 250 milliseconds, which is 4 clicks per second. You get data something like below. (sec):(ms) 1:000 1:250 1:500 1:750 2:000 2:250 2:500 2:750 3:000 3:250 3:500 3:750 (lets say i execute some windows event)(time will skew) 4:122 4:388 4:600 4:876 (stop doing what i was doing in windows) (going to shorten the data for simplicit, my list was 30sec long) 5:124 5:268 5:500 5:750 (you would se the time go back the same milliseconds it was at the begining) 6:000 6:250 6:500 6:750 7:000 7:250 7:500 7:750 So i'm thinking the timer continues to fire on the same millisecond every time, but its the event that is being skewed to fire off time by other windows operations. Its not a huge skew, but for what i need to accomplish, its unacceptable. Is there anyhting i can do in .NET, hoping to use XAML/WPF application, thats will correct the skewing of events? thx.

    Read the article

  • Why am I losing precision when populating an NSDecimalNumber with a double?

    - by Mike
    Here is a simple code that shows what I think is a bug when dealing with double numbers... double wtf = 36.76662445068359375000; id xxx = [NSDecimalNumber numberWithDouble: wtf]; NSString *myBug = [xxx stringValue]; NSLog(@"%.20f", wtf); NSLog(@"%@", myBug); NSLog(@"-------\n"); the terminal will show two different numbers 36.76662445068359375000 and 36.76662445068359168 Is this a bug or am I missing something? if the second number is being rounded, it is a very strange rounding btw...

    Read the article

  • Anyone know how to get dual screens working on a Dell E6410 laptop with Ubuntu 10.04 64 bit?

    - by Curtis
    I've installed the drivers from nVidia. When I go into the NVIDIA X Server Settings application, in the X Server Display Configuration setcion, and click the "Configure" button, "TwinView" is disabled. Also, clicking "Detect Displays" doesn't pick up my monitor (which is connected through a port replicator - keyboard and mouse in that port replicator work fine). Has anyone else seen this? Is this just a limitation of the current nvidia linux drivers?

    Read the article

  • The internal storage of a DATETIME2 value

    - by Peter Larsson
    Today I went for investigating the internal storage of DATETIME2 datatype. What I found out was that for a datetime2 value with precision 0 (seconds only), SQL Server need 6 bytes to represent the value, but stores 7 bytes. This is because SQL Server add one byte that holds the precision for the datetime2 value. Start with this very simple repro declare @now datetime2(7) = '2010-12-15 21:04:03.6934231'   select  cast(cast(@now as datetime2(0)) as binary(7)),         cast(cast(@now as datetime2(1)) as binary(7)),         cast(cast(@now as datetime2(2)) as binary(7)),         cast(cast(@now as datetime2(3)) as binary(8)),         cast(cast(@now as datetime2(4)) as binary(8)),         cast(cast(@now as datetime2(5)) as binary(9)),         cast(cast(@now as datetime2(6)) as binary(9)),         cast(cast(@now as datetime2(7)) as binary(9)) Now we are going to copy and paste these binary values and investigate which value is representing what time part. Prefix  Ticks       Ticks         Days    Days    Original value ------  ----------  ------------  ------  ------  -------------------- 0x  00  442801             75844  A8330B  734120  0x00442801A8330B 0x  01  A5920B            758437  A8330B  734120  0x01A5920BA8330B  0x  02  71BA73           7584369  A8330B  734120  0x0271BA73A8330B 0x  03  6D488504        75843693  A8330B  734120  0x036D488504A8330B 0x  04  46D4342D       758436934  A8330B  734120  0x0446D4342DA8330B 0x  05  BE4A10C401    7584369342  A8330B  734120  0x05BE4A10C401A8330B 0x  06  6FEBA2A811   75843693423  A8330B  734120  0x066FEBA2A811A8330B 0x  07  57325D96B0  758436934231  A8330B  734120  0x0757325D96B0A8330B Let us use the following color schema Red - Prefix Green - Time part Blue - Day part What you can see is that the date part is equal in all cases, which makes sense since the precision doesm't affect the datepart. What would have been fun, is datetime2(negative) just like round accepts a negative value. -1 would mean rounding to 10 second, -2 rounding to minute, -3 rounding to 10 minutes, -4 rounding to hour and finally -5 rounding to 10 hour. -5 is pretty useless, but if you extend this thinking to -6, -7 and so on, you could actually get a datetime2 value which is accurate to the month only. Well, enough ranting about this. Let's get back to the table above. If you add 75844 second to midnight, you get 21:04:04, which is exactly what you got in the select statement above. And if you look at it, it makes perfect sense that each following value is 10 times greater when the precision is increased one step too. //Peter

    Read the article

  • Getting Wireless working on Dell Inspiron 1545 in Ubuntu 10.04?

    - by Dexter
    I'm trying to install my wireless drivers (which uses a broadcom card). I tried to install them using the restricted drivers offered on my Ubuntu CD. However when I clicked activate it got about halfway through the install process before it gave me this error message: SystemError: installArchives() failed How can I correct this?

    Read the article

  • The internal storage of a DATETIMEOFFSET value

    - by Peter Larsson
    Today I went for investigating the internal storage of DATETIME2 datatype. What I found out was that for a datetime2 value with precision 0 (seconds only), SQL Server need 6 bytes to represent the value, but stores 7 bytes. This is because SQL Server add one byte that holds the precision for the datetime2 value. Start with this very simple repro declare    @now datetimeoffset(7) = '2010-12-15 21:04:03.6934231 +03:30'   select     cast(cast(@now as datetimeoffset(0)) as binary(9)),            cast(cast(@now as datetimeoffset(1)) as binary(9)),            cast(cast(@now as datetimeoffset(2)) as binary(9)),            cast(cast(@now as datetimeoffset(3)) as binary(10)),            cast(cast(@now as datetimeoffset(4)) as binary(10)),            cast(cast(@now as datetimeoffset(5)) as binary(11)),            cast(cast(@now as datetimeoffset(6)) as binary(11)),            cast(cast(@now as datetimeoffset(7)) as binary(11)) Now we are going to copy and paste these binary values and investigate which value is representing what time part. Prefix  Ticks       Ticks         Days    Days    Suffix  Suffix  Original value ------  ----------  ------------  ------  ------  ------  ------  ------------------------ 0x  00  0CF700             63244  A8330B  734120  D200       210  0x000CF700A8330BD200 0x  01  75A609            632437  A8330B  734120  D200       210 0x0175A609A8330BD200 0x  02  918060           6324369  A8330B  734120  D200       210  0x02918060A8330BD200 0x  03  AD05C503        63243693  A8330B  734120  D200       210  0x03AD05C503A8330BD200 0x  04  C638B225       632502470  A8330B  734120  D200       210  0x04C638B225A8330BD200 0x  05  BE37F67801    6324369342  A8330B  734120  D200       210  0x05BE37F67801A8330BD200 0x  06  6F2D9EB90E   63243693423  A8330B  734120  D200       210  0x066F2D9EB90EA8330BD200 0x  07  57C62D4093  632436934231  A8330B  734120  D200       210  0x0757C62D4093A8330BD200 Let us use the following color schema Red - Prefix Green - Time part Blue - Day part Purple - UTC offset What you can see is that the date part is equal in all cases, which makes sense since the precision doesn't affect the datepart. If you add 63244 seconds to midnight, you get 17:34:04, which is the correct UTC time. So what is stored is the UTC time and the local time can be found by adding "utc offset" minutes. And if you look at it, it makes perfect sense that each following value is 10 times greater when the precision is increased one step too. //Peter

    Read the article

  • Anyone know how to get dual screens working on a Dell E6410 laptop with Ubuntu 10.04 64 bit?

    - by Curtis
    I've installed the drivers from nVidia. When I go into the NVIDIA X Server Settings application, in the X Server Display Configuration setcion, and click the "Configure" button, "TwinView" is disabled. Also, clicking "Detect Displays" doesn't pick up my monitor (which is connected through a port replicator - keyboard and mouse in that port replicator work fine). Has anyone else seen this? Is this just a limitation of the current nvidia linux drivers?

    Read the article

  • Dell Windows 7 DVD includes IE9, where to find IE8?

    - by mjmcinto
    It appears as though we can now only get a 64 bit installation of windows 7 to come with IE9, and I cannot find an installer for IE 8 for it. This presents a problem, as I am building a new machine for a developer, but the company does not support IE9 yet, and all development needs to be able to be run on IE8. I would rather have them on a 64 bit version of windows so they can have more than 4GB of RAM (can get IE8 on 32 bit win 7). Does anyone know how to get IE 8 on a new 64 bit version of win 7?

    Read the article

  • Does the Dell Inspiron 1501 handle more than 4 Gb of RAM?

    - by zillion
    After the following comment on my last question, I'm thinking about upgrading my RAM: I got a 160 GB Scorpio Blue a couple months ago for my 1501. It's nice. That + 2 GB Crucial RAM have rather revived my notebook (meaning a very nice speed and storage boost). I was outgrowing it... – Nathaniel What would be the best choice to add more RAM? I've already got 2 GB, but I'm not sure what their speed is. What are the size, type and speed limitations for RAM on my particular laptop?

    Read the article

  • Dell Vostro 3500 battery life remaining missing from Windows 8?

    - by Misha
    On Windows 7 a Vostro 3500 laptop shows the battery life remaining, while on Windows 8 this information appears to be missing. The percentage is still available, but the life remaining is missing. How is battery life remaining calculated and does this require some level of driver support? Is it a standardized interface? Does anybody know which driver is responsible for handling this feature? I want to force the old Windows 7 driver, but I don't know which driver does battery remaining.

    Read the article

  • I have to manually enter the pwd when I login at school and when I come back home with my laptop (DELL E6410)

    - by Bong Paduano
    I didn't have to do this the first 3 months of me going to school. My laptop used to be able to connect to my Home WiFi and school Wifi automatically then after the 3rd month something changed and eversince then I literally have to manually enter each of the Wifi passwords in each location each time I try to connect to their respective WLAN. I tried adding each WiFi networks in the "Manage wireless networks" section in the Network and Sharing Center but everytime I login to one of the location, the created network disappears and I did this more than once. I tried restoring the OS back but to no avail. Can someone please assist me on this issue. I'm not sure if this issue has been addressed in this website but I haven't seen any similar question in here. I appreciate any help anyone may be able to share.

    Read the article

  • Sniffing out SQL Code Smells: Inconsistent use of Symbolic names and Datatypes

    - by Phil Factor
    It is an awkward feeling. You’ve just delivered a database application that seems to be working fine in production, and you just run a few checks on it. You discover that there is a potential bug that, out of sheer good chance, hasn’t kicked in to produce an error; but it lurks, like a smoking bomb. Worse, maybe you find that the bug has started its evil work of corrupting the data, but in ways that nobody has, so far detected. You investigate, and find the damage. You are somehow going to have to repair it. Yes, it still very occasionally happens to me. It is not a nice feeling, and I do anything I can to prevent it happening. That’s why I’m interested in SQL code smells. SQL Code Smells aren’t necessarily bad practices, but just show you where to focus your attention when checking an application. Sometimes with databases the bugs can be subtle. SQL is rather like HTML: the language does its best to try to carry out your wishes, rather than to be picky about your bugs. Most of the time, this is a great benefit, but not always. One particular place where this can be detrimental is where you have implicit conversion between different data types. Most of the time it is completely harmless but we’re  concerned about the occasional time it isn’t. Let’s give an example: String truncation. Let’s give another even more frightening one, rounding errors on assignment to a number of different precision. Each requires a blog-post to explain in detail and I’m not now going to try. Just remember that it is not always a good idea to assign data to variables, parameters or even columns when they aren’t the same datatype, especially if you are relying on implicit conversion to work its magic.For details of the problem and the consequences, see here:  SR0014: Data loss might occur when casting from {Type1} to {Type2} . For any experienced Database Developer, this is a more frightening read than a Vampire Story. This is why one of the SQL Code Smells that makes me edgy, in my own or other peoples’ code, is to see parameters, variables and columns that have the same names and different datatypes. Whereas quite a lot of this is perfectly normal and natural, you need to check in case one of two things have gone wrong. Either sloppy naming, or mixed datatypes. Sure it is hard to remember whether you decided that the length of a log entry was 80 or 100 characters long, or the precision of a number. That is why a little check like this I’m going to show you is excellent for tidying up your code before you check it back into source Control! 1/ Checking Parameters only If you were just going to check parameters, you might just do this. It simply groups all the parameters, either input or output, of all the routines (e.g. stored procedures or functions) by their name and checks to see, in the HAVING clause, whether their data types are all the same. If not, it lists all the examples and their origin (the routine) Even this little check can occasionally be scarily revealing. ;WITH userParameter AS  ( SELECT   c.NAME AS ParameterName,  OBJECT_SCHEMA_NAME(c.object_ID) + '.' + OBJECT_NAME(c.object_ID) AS ObjectName,  t.name + ' '     + CASE     --we may have to put in the length            WHEN t.name IN ('char', 'varchar', 'nchar', 'nvarchar')             THEN '('               + CASE WHEN c.max_length = -1 THEN 'MAX'                ELSE CONVERT(VARCHAR(4),                    CASE WHEN t.name IN ('nchar', 'nvarchar')                      THEN c.max_length / 2 ELSE c.max_length                    END)                END + ')'         WHEN t.name IN ('decimal', 'numeric')             THEN '(' + CONVERT(VARCHAR(4), c.precision)                   + ',' + CONVERT(VARCHAR(4), c.Scale) + ')'         ELSE ''      END  --we've done with putting in the length      + CASE WHEN XML_collection_ID <> 0         THEN --deal with object schema names             '(' + CASE WHEN is_XML_Document = 1                    THEN 'DOCUMENT '                    ELSE 'CONTENT '                   END              + COALESCE(               (SELECT QUOTENAME(ss.name) + '.' + QUOTENAME(sc.name)                FROM sys.xml_schema_collections sc                INNER JOIN Sys.Schemas ss ON sc.schema_ID = ss.schema_ID                WHERE sc.xml_collection_ID = c.XML_collection_ID),'NULL') + ')'          ELSE ''         END        AS [DataType]  FROM sys.parameters c  INNER JOIN sys.types t ON c.user_Type_ID = t.user_Type_ID  WHERE OBJECT_SCHEMA_NAME(c.object_ID) <> 'sys'   AND parameter_id>0)SELECT CONVERT(CHAR(80),objectName+'.'+ParameterName),DataType FROM UserParameterWHERE ParameterName IN   (SELECT ParameterName FROM UserParameter    GROUP BY ParameterName    HAVING MIN(Datatype)<>MAX(DataType))ORDER BY ParameterName   so, in a very small example here, we have a @ClosingDelimiter variable that is only CHAR(1) when, by the looks of it, it should be up to ten characters long, or even worse, a function that should be a char(1) and seems to let in a string of ten characters. Worth investigating. Then we have a @Comment variable that can't decide whether it is a VARCHAR(2000) or a VARCHAR(MAX) 2/ Columns and Parameters Actually, once we’ve cleared up the mess we’ve made of our parameter-naming in the database we’re inspecting, we’re going to be more interested in listing both columns and parameters. We can do this by modifying the routine to list columns as well as parameters. Because of the slight complexity of creating the string version of the datatypes, we will create a fake table of both columns and parameters so that they can both be processed the same way. After all, we want the datatypes to match Unfortunately, parameters do not expose all the attributes we are interested in, such as whether they are nullable (oh yes, subtle bugs happen if this isn’t consistent for a datatype). We’ll have to leave them out for this check. Voila! A slight modification of the first routine ;WITH userObject AS  ( SELECT   Name AS DataName,--the actual name of the parameter or column ('@' removed)  --and the qualified object name of the routine  OBJECT_SCHEMA_NAME(ObjectID) + '.' + OBJECT_NAME(ObjectID) AS ObjectName,  --now the harder bit: the definition of the datatype.  TypeName + ' '     + CASE     --we may have to put in the length. e.g. CHAR (10)           WHEN TypeName IN ('char', 'varchar', 'nchar', 'nvarchar')             THEN '('               + CASE WHEN MaxLength = -1 THEN 'MAX'                ELSE CONVERT(VARCHAR(4),                    CASE WHEN TypeName IN ('nchar', 'nvarchar')                      THEN MaxLength / 2 ELSE MaxLength                    END)                END + ')'         WHEN TypeName IN ('decimal', 'numeric')--a BCD number!             THEN '(' + CONVERT(VARCHAR(4), Precision)                   + ',' + CONVERT(VARCHAR(4), Scale) + ')'         ELSE ''      END  --we've done with putting in the length      + CASE WHEN XML_collection_ID <> 0 --tush tush. XML         THEN --deal with object schema names             '(' + CASE WHEN is_XML_Document = 1                    THEN 'DOCUMENT '                    ELSE 'CONTENT '                   END              + COALESCE(               (SELECT TOP 1 QUOTENAME(ss.name) + '.' + QUOTENAME(sc.Name)                FROM sys.xml_schema_collections sc                INNER JOIN Sys.Schemas ss ON sc.schema_ID = ss.schema_ID                WHERE sc.xml_collection_ID = XML_collection_ID),'NULL') + ')'          ELSE ''         END        AS [DataType],       DataObjectType  FROM   (Select t.name AS TypeName, REPLACE(c.name,'@','') AS Name,          c.max_length AS MaxLength, c.precision AS [Precision],           c.scale AS [Scale], c.[Object_id] AS ObjectID, XML_collection_ID,          is_XML_Document,'P' AS DataobjectType  FROM sys.parameters c  INNER JOIN sys.types t ON c.user_Type_ID = t.user_Type_ID  AND parameter_id>0  UNION all  Select t.name AS TypeName, c.name AS Name, c.max_length AS MaxLength,          c.precision AS [Precision], c.scale AS [Scale],          c.[Object_id] AS ObjectID, XML_collection_ID,is_XML_Document,          'C' AS DataobjectType            FROM sys.columns c  INNER JOIN sys.types t ON c.user_Type_ID = t.user_Type_ID   WHERE OBJECT_SCHEMA_NAME(c.object_ID) <> 'sys'  )f)SELECT CONVERT(CHAR(80),objectName+'.'   + CASE WHEN DataobjectType ='P' THEN '@' ELSE '' END + DataName),DataType FROM UserObjectWHERE DataName IN   (SELECT DataName FROM UserObject   GROUP BY DataName    HAVING MIN(Datatype)<>MAX(DataType))ORDER BY DataName     Hmm. I can tell you I found quite a few minor issues with the various tabases I tested this on, and found some potential bugs that really leap out at you from the results. Here is the start of the result for AdventureWorks. Yes, AccountNumber is, for some reason, a Varchar(10) in the Customer table. Hmm. odd. Why is a city fifty characters long in that view?  The idea of the description of a colour being 256 characters long seems over-ambitious. Go down the list and you'll spot other mistakes. There are no bugs, but just mess. We started out with a listing to examine parameters, then we mixed parameters and columns. Our last listing is for a slightly more in-depth look at table columns. You’ll notice that we’ve delibarately removed the indication of whether a column is persisted, or is an identity column because that gives us false positives for our code smells. If you just want to browse your metadata for other reasons (and it can quite help in some circumstances) then uncomment them! ;WITH userColumns AS  ( SELECT   c.NAME AS columnName,  OBJECT_SCHEMA_NAME(c.object_ID) + '.' + OBJECT_NAME(c.object_ID) AS ObjectName,  REPLACE(t.name + ' '   + CASE WHEN is_computed = 1 THEN ' AS ' + --do DDL for a computed column          (SELECT definition FROM sys.computed_columns cc           WHERE cc.object_id = c.object_id AND cc.column_ID = c.column_ID)     --we may have to put in the length            WHEN t.Name IN ('char', 'varchar', 'nchar', 'nvarchar')             THEN '('               + CASE WHEN c.Max_Length = -1 THEN 'MAX'                ELSE CONVERT(VARCHAR(4),                    CASE WHEN t.Name IN ('nchar', 'nvarchar')                      THEN c.Max_Length / 2 ELSE c.Max_Length                    END)                END + ')'       WHEN t.name IN ('decimal', 'numeric')       THEN '(' + CONVERT(VARCHAR(4), c.precision) + ',' + CONVERT(VARCHAR(4), c.Scale) + ')'       ELSE ''      END + CASE WHEN c.is_rowguidcol = 1          THEN ' ROWGUIDCOL'          ELSE ''         END + CASE WHEN XML_collection_ID <> 0            THEN --deal with object schema names             '(' + CASE WHEN is_XML_Document = 1                THEN 'DOCUMENT '                ELSE 'CONTENT '               END + COALESCE((SELECT                QUOTENAME(ss.name) + '.' + QUOTENAME(sc.name)                FROM                sys.xml_schema_collections sc                INNER JOIN Sys.Schemas ss ON sc.schema_ID = ss.schema_ID                WHERE                sc.xml_collection_ID = c.XML_collection_ID),                'NULL') + ')'            ELSE ''           END + CASE WHEN is_identity = 1             THEN CASE WHEN OBJECTPROPERTY(object_id,                'IsUserTable') = 1 AND COLUMNPROPERTY(object_id,                c.name,                'IsIDNotForRepl') = 0 AND OBJECTPROPERTY(object_id,                'IsMSShipped') = 0                THEN ''                ELSE ' NOT FOR REPLICATION '               END             ELSE ''            END + CASE WHEN c.is_nullable = 0               THEN ' NOT NULL'               ELSE ' NULL'              END + CASE                WHEN c.default_object_id <> 0                THEN ' DEFAULT ' + object_Definition(c.default_object_id)                ELSE ''               END + CASE                WHEN c.collation_name IS NULL                THEN ''                WHEN c.collation_name <> (SELECT                collation_name                FROM                sys.databases                WHERE                name = DB_NAME()) COLLATE Latin1_General_CI_AS                THEN COALESCE(' COLLATE ' + c.collation_name,                '')                ELSE ''                END,'  ',' ') AS [DataType]FROM sys.columns c  INNER JOIN sys.types t ON c.user_Type_ID = t.user_Type_ID  WHERE OBJECT_SCHEMA_NAME(c.object_ID) <> 'sys')SELECT CONVERT(CHAR(80),objectName+'.'+columnName),DataType FROM UserColumnsWHERE columnName IN (SELECT columnName FROM UserColumns  GROUP BY columnName  HAVING MIN(Datatype)<>MAX(DataType))ORDER BY columnName If you take a look down the results against Adventureworks, you'll see once again that there are things to investigate, mostly, in the illustration, discrepancies between null and non-null datatypes So I here you ask, what about temporary variables within routines? If ever there was a source of elusive bugs, you'll find it there. Sadly, these temporary variables are not stored in the metadata so we'll have to find a more subtle way of flushing these out, and that will, I'm afraid, have to wait!

    Read the article

  • What DX level does my graphics card support? Does it go to 11?

    - by Daniel Moth
    Recently I run into a situation that I have run into quite a few times. Someone encounters a machine and the question arises: "Is there a DirectX 11 card in this machine?". Typically the reason you are interested in that is because cards with DirectX 11 drivers fully support DirectCompute (and by extension C++ AMP) for GPGPU programming. The driver specifically is WDDM (1.1 on Windows 7 and Windows 8 introduces WDDM 1.2 with cool new capabilities). There are many ways for figuring out if you have a DirectX11 card, so here are the approaches that you can use, with a bonus right at the end of the post. Run DxDiag WindowsKey + R, type DxDiag and hit Enter. That is the DirectX diagnostic tool, which unfortunately, only tells you on the "System" tab what is the highest version of DirectX installed on your machine. So if it reports DirectX 11, that doesn't mean you have a DX11 driver! The "Display" tab has a promising "DDI version" label, but unfortunately that doesn't seem to be accurate on the machines I've tested it with (or I may be misinterpreting its use). Either way, this tool is not the one you want for this purpose, although it is good for telling you the WDDM version among other things. Use the Microsoft hardware page There is a Microsoft Windows 7 compatibility center, that lists all hardware (tip: use the advanced search) and you could try and locate your device there… good luck. Use Wikipedia or the hardware vendor's website Use the Wikipedia page for the vendor cards, for both nvidia and amd. Often this information will also be in the specifications for the cards on the IHV site, but is is nice that wikipedia has a single page per vendor that you can search etc. There is a column in the tables for API support where you can see the DirectX version. Check if it is one of these recommended DX11 cards You may not have a DirectX 11 card and are interested in purchasing one. While I am in no position to make recommendations, I will list here some cards from two big IHVs that we know are DirectX 11 capable. Some AMD (aka ATI) cards Low end, inexpensive DX11 hardware: Radeon 5450, 5550, 6450, 6570 Mid range (decent perf, single precision): Radeon 5750, 5770, 6770, 6790 High end (capable of double precision): Radeon 5850, 5870, 6950, 6970 Single precision APUs: AMD E-Series APUs AMD A-Series APUs Some NVIDIA cards Low end, inexpensive DX11 hardware: GeForce GT430, GT 440, GT520, GTS 450 Quadro 400, 600 Mid-range (decent perf, single precision): GeForce GTX 460, GTX 550 Ti, GTX 560, GTX 560 Ti Quadro 2000 High end (capable of double precision): GeForce GTX 480, GTX 570, GTX 580, GTX 590, GTX 595 Quadro 4000, 5000, 6000 Tesla C2050, C2070, C2075 Get the DirectX SDK and run DirectX Caps Viewer Download and install the June 2010 DirectX SDK. As part of that you now have the DirectX Capabilities Viewer utility (find it in your start menu by searching for "DirectX Caps Viewer", the filename is DXCapsViewer.exe). It will list all your devices (emulated, and real hardware ones) under the first node. Expand the hardware entries and then expand again the Direct3D 11 folder. If you see D3D_FEATURE_LEVEL_11_ under that, then your card supports feature level 11 which means it supports DirectCompute and C++ AMP. In the following screenshot of one of my old laptops, the card only goes to feature level 10. Run a utility from the web that just tells you! Of course, writing some C++ AMP code that enumerates accelerators and lists the ones that are capable is trivial. However that requires that you have redistributed the runtime, so a more broadly applicable approach is to use the DX APIs directly to enumerate the DX11 capable cards. That is exactly what the development lead for C++ AMP has done and he describes and shares that utility at this post. Comments about this post by Daniel Moth welcome at the original blog.

    Read the article

  • What DX level does my graphics card support? Does it go to 11?

    - by Daniel Moth
    Recently I run into a situation that I have run into quite a few times. Someone encounters a machine and the question arises: "Is there a DirectX 11 card in this machine?". Typically the reason you are interested in that is because cards with DirectX 11 drivers fully support DirectCompute (and by extension C++ AMP) for GPGPU programming. The driver specifically is WDDM (1.1 on Windows 7 and Windows 8 introduces WDDM 1.2 with cool new capabilities). There are many ways for figuring out if you have a DirectX11 card, so here are the approaches that you can use, with a bonus right at the end of the post. Run DxDiag WindowsKey + R, type DxDiag and hit Enter. That is the DirectX diagnostic tool, which unfortunately, only tells you on the "System" tab what is the highest version of DirectX installed on your machine. So if it reports DirectX 11, that doesn't mean you have a DX11 driver! The "Display" tab has a promising "DDI version" label, but unfortunately that doesn't seem to be accurate on the machines I've tested it with (or I may be misinterpreting its use). Either way, this tool is not the one you want for this purpose, although it is good for telling you the WDDM version among other things. Use the Microsoft hardware page There is a Microsoft Windows 7 compatibility center, that lists all hardware (tip: use the advanced search) and you could try and locate your device there… good luck. Use Wikipedia or the hardware vendor's website Use the Wikipedia page for the vendor cards, for both nvidia and amd. Often this information will also be in the specifications for the cards on the IHV site, but is is nice that wikipedia has a single page per vendor that you can search etc. There is a column in the tables for API support where you can see the DirectX version. Check if it is one of these recommended DX11 cards You may not have a DirectX 11 card and are interested in purchasing one. While I am in no position to make recommendations, I will list here some cards from two big IHVs that we know are DirectX 11 capable. Some AMD (aka ATI) cards Low end, inexpensive DX11 hardware: Radeon 5450, 5550, 6450, 6570 Mid range (decent perf, single precision): Radeon 5750, 5770, 6770, 6790 High end (capable of double precision): Radeon 5850, 5870, 6950, 6970 Single precision APUs: AMD E-Series APUs AMD A-Series APUs Some NVIDIA cards Low end, inexpensive DX11 hardware: GeForce GT430, GT 440, GT520, GTS 450 Quadro 400, 600 Mid-range (decent perf, single precision): GeForce GTX 460, GTX 550 Ti, GTX 560, GTX 560 Ti Quadro 2000 High end (capable of double precision): GeForce GTX 480, GTX 570, GTX 580, GTX 590, GTX 595 Quadro 4000, 5000, 6000 Tesla C2050, C2070, C2075 Get the DirectX SDK and run DirectX Caps Viewer Download and install the June 2010 DirectX SDK. As part of that you now have the DirectX Capabilities Viewer utility (find it in your start menu by searching for "DirectX Caps Viewer", the filename is DXCapsViewer.exe). It will list all your devices (emulated, and real hardware ones) under the first node. Expand the hardware entries and then expand again the Direct3D 11 folder. If you see D3D_FEATURE_LEVEL_11_ under that, then your card supports feature level 11 which means it supports DirectCompute and C++ AMP. In the following screenshot of one of my old laptops, the card only goes to feature level 10. Run a utility from the web that just tells you! Of course, writing some C++ AMP code that enumerates accelerators and lists the ones that are capable is trivial. However that requires that you have redistributed the runtime, so a more broadly applicable approach is to use the DX APIs directly to enumerate the DX11 capable cards. That is exactly what the development lead for C++ AMP has done and he describes and shares that utility at this post. Comments about this post by Daniel Moth welcome at the original blog.

    Read the article

  • Floating point conversion from Fixed point algorithm

    - by Viks
    Hi, I have an application which is using 24 bit fixed point calculation.I am porting it to a hardware which does support floating point, so for speed optimization I need to convert all fixed point based calculation to floating point based calculation. For this code snippet, It is calculating mantissa for(i=0;i<8207;i++) { // Do n^8/7 calculation and store // it in mantissa and exponent, scaled to // fixed point precision. } So since this calculation, does convert an integer to mantissa and exponent scaled to fixed point precision(23 bit). When I tried converting it to float, by dividing the mantissa part by precision bits and subtracting the exponent part by precision bit, it really does' t work. Please help suggesting a better way of doing it.

    Read the article

  • What Determines the Default Setting of the x87 FPU Control Word?

    - by Rick Regan
    What determines the default setting of the x87 FPU control word -- specifically, the precision control field? Does the compiler set it based on the target processor? Is there a compiler option to change it? Using Microsoft Visual C++ 2008 Express Edition on an Intel Core Duo processor, the default setting for the precision control field is "01b", meaning double (53 bit) precision. I'm wondering -- why is the default not "11"b, or extended (64 bit) precision? (I know I can change it using _controlfp.)

    Read the article

  • please help me to interpret the naive bayes result in weka..

    - by resmi
    Anybody please help me to interpret the following result generated in weka for classification using naive bayes.....Please explain clearly what is this Normal Distribution , Mean , StandardDev , WeightSum and Precision.Please help me.Am new in weka. ** Naive Bayes Classifier Class Normal: Prior probability = 0.5 1374195_at: Normal Distribution. Mean = 218.06 StandardDev = 6.0572 WeightSum = 3 Precision = 36.34333334 1373315_at: Normal Distribution. Mean = 1142.58 StandardDev = 21.1589 WeightSum = 3 Precision = 126.95333339999999

    Read the article

  • MPFR Rounding 0.9999 to 1?

    - by Silmaersti
    I'm attempting to store the value 0.9999 into an mpfr_t variable But 0.9999 is rounded to 1 (or some other value != 0.9999) during storage, no matter the round value (GMP_RNDD, GMP_RNDU, GMP_RNDN, GMP_RNDZ) So what's the best method to store 0.9999 in an mpfr_t variable? Is it possible? Here is my test program, it prints "buffer is: 1", instead of the wanted "buffer is: 0.9999": int main() { size_t precision = 4; mpfr_t mpfrValue; mpfr_init2(mpfrValue, precision); mpfr_set_str(mpfrValue, "0.9999", 10, GMP_RNDN); char *buffer = (char*)malloc((sizeof(char) * precision) + 3); mp_exp_t exponent; mpfr_get_str(buffer, &exponent, 10, precision, mpfrValue, GMP_RNDN); printf("buffer is: %s\n", buffer); free(buffer); mpfr_clear(mpfrValue); return 0; } Thanks for any help !

    Read the article

  • Fortran severe (40) Error... Help?!

    - by Taka
    I can compile but when I run I get this error "forrtl: severe (40): recursive I/O operation, unit -1, file unknown" if I set n = 29 or more... Can anyone help with where I might have gone wrong? Thanks. PROGRAM SOLUTION IMPLICIT NONE ! Variable Declaration INTEGER :: i REAL :: dt DOUBLE PRECISION :: st(0:9) DOUBLE PRECISION :: stmean(0:9) DOUBLE PRECISION :: first_argument DOUBLE PRECISION :: second_argument DOUBLE PRECISION :: lci, uci, mean REAL :: exp1, n REAL :: r, segma ! Get inputs WRITE(*,*) 'Please enter number of trials: ' READ(*,*) n WRITE(*,*) dt=1.0 segma=0.2 r=0.1 ! For n Trials st(0)=35.0 stmean(0)=35.0 mean = stmean(0) PRINT *, 'For ', n ,' Trials' PRINT *,' 1 ',st(0) ! Calculate results DO i=0, n-2 first_argument = r-(1/2*(segma*segma))*dt exp1 = -(1/2)*(i*i) second_argument = segma*sqrt(dt)*((1/sqrt(2*3.1416))*exp(exp1)) st(i+1) = st(i) * exp(first_argument+second_argument) IF(st(i+1)<=20) THEN stmean(i+1) = 0.0 st(i+1) = st(i) else stmean(i+1) = st(i+1) ENDIF PRINT *,i+2,' ',stmean(i+1) mean = mean+stmean(i+1) END DO ! Output results uci = mean+(1.96*(segma/sqrt(n))) lci = mean-(1.96*(segma/sqrt(n))) PRINT *,'95% Confidence Interval for ', n, ' trials is between ', lci, ' and ', uci PRINT *,'' END PROGRAM SOLUTION

    Read the article

< Previous Page | 38 39 40 41 42 43 44 45 46 47 48 49  | Next Page >