Search Results

Search found 54398 results on 2176 pages for 'long running processes'.

Page 42/2176 | < Previous Page | 38 39 40 41 42 43 44 45 46 47 48 49  | Next Page >

  • Problem with running a program from flashdrive

    - by rajivpradeep
    I have a USB drive with two partitions in it, one hidden and one normal. I have an application which swaps the memory and runs the flash application in hidden zone. The problem is that the application works fine on Windows 7 and when run on Win XP, it swaps the partitions but doesn't run the flash applications but just keeps running in the background. I can see it in task manager. But, when I copy the application to desktop and run, it runs with no glitch. I was facing the same problem on Win 7 too, but it was running as required when I ran it using "Run in XP mode" and then I applied a SHIM and is running since then as required. The application is built using VC++ 2008. does anyone know the solution?

    Read the article

  • Problem with running a program from flashdrive

    - by rajivpradeep
    I have a USB drive with two partitions in it, one hidden and one normal. I have an application which swaps the memory and runs the flash application in hidden zone. The problem is that the application works fine on Windows 7 and when run on Win XP, it swaps the partitions but doesn't run the flash applications but just keeps running in the background. I can see it in task manager. But, when I copy the application to desktop and run, it runs with no glitch. I was facing the same problem on Win 7 too, but it was running as required when I ran it using "Run in XP mode" and then I applied a SHIM and is running since then as required. The application is built using VC++ 2008. does anyone know the solution?

    Read the article

  • Why Java applicaiton is running slow for clients on Linux

    - by Darshani
    We have two linux servers which have Apache Tomcat Installed. One is running the Database, the other is running with Java application. More than 100 users are connected to the servers. Server machines are quad core normal PC's which have 4 GB memory. It was running properly for the last 6 months but the application has recently started to run slowly . Suddenly the Java application is getting stuck & users cannot work for some time. There is no network issue. I am trying to identify the reason for this, whether it is a machine problem or the problem is in the Java application. Can any body help me with this?

    Read the article

  • Squid closing the connection on long HTTP GET requests

    - by Rhys
    When running a database query on a specific external site we use, Squid seems to cut off the connection after a consistent period of time (just over a minute). The query is submitted through a standard web form is that uses GET to query their database. Firefox 3 just displays a blank page. Internet Explorer throws a 'Page Cannot Be Displayed' error (tested in v6 and v8). When we perform the same query on the same machine, but bypass the Squid proxy, it works fine. The query takes about two and a half minutes to complete. There are a few timeout settings in Squid, but I honestly don't know what one to be looking at. Any possible solutions would be much appreciated. Cheers

    Read the article

  • Running RAID on an internal storage drive

    - by Johnny W
    I am running Windows 8 on an SSD, and it's all running swimmingly, but I want to put my documents on a "normal" HD running under RAID 1. I have four SATA 3GB/s ports on my motherboard (my Windows 8 SSD drive in on a different 6GB/s controller). All four are used (1 Bluray Optical Drive, 1 Spare HD, and the 2 I wish to turn into a RAID 1 drive. In my BIOS I can only change settings for the entire controller, not just ports. So my question is: If I turn these four ports into a RAID controller, will that negatively affect the non-RAID hardware plugged into it? I.e. Will a HD or Bluray drive be slower/incompatible with being plugged into a non AHCI SATA port? Thanks.

    Read the article

  • Shell Script to Start Mysql Server if not running

    - by user103373
    I have written a shell script to start mysql server & send a mail to admin user if it's restarted via shell script. What i am facing an issue if I run this shell script on terminal it's work perfectly & If same script runs via cronjob it's only sending the mail to the user & problem remains same. Is this problem relates to permission & how can i resolve it. Shell Script-------- #!/bin/bash EMAIL="[email protected]" SERVICE='mysql' if ps ax | grep -v grep | grep $SERVICE > /dev/null then echo "$SERVICE service running, everything is fine" else echo "$SERVICE is not running" /etc/init.d/mysql start cat <<EOF | msmtp -a gmail $EMAIL Subject: "Alert (Test Server) : Mysql Service is not running (Manually Restarted)" Mysql Server Restarted at: `date` EOF EXIT I am using msmtp for sending mail to the user on ubuntu 12.04 Server.

    Read the article

  • Ensure a process is running on a remote computer

    - by awilinsk
    We have about ten client computers ranging from Windows XP to Windows 7 that have a little program that runs in the tray. This program needs to be running at all times and sometimes it either crashes or a user exits the program. We would like to be able to check every hour or so to see if this program is running. If it is not running, it should be started. I have tried using powershell on one of our servers to get the process from a remote computer and if it doesn't find it, to start it. But, that fails because it cannot start the process as an interactive user. I tried setting up a task in task scheduler, but Windows XP task scheduler is not very good or configurable. We would like this to be as easy to administer as possible. What would be the best way to do this?

    Read the article

  • Firefox Address Bar Search Returns Web Server Running?

    - by Stix
    When I type "trends" in Firefox 25.0 address bar, it returns what looks like a web server running on my PC, although I am not running a web server. I don't have the score to post the screen shot, but specifically it says: It works! This is the default web page for this server. The web server software is running but no content has been added, yet. Why would this display, instead of the normal behavior of the search engine? I'm using Windows 7 with the Anaconda Python distribution installed, but there is no Python interpreter fired up.

    Read the article

  • On mobile is there a reason why processes are often short lived and must persist their state explicitly?

    - by Alexandre Jasmin
    Most mobile platforms (such as Android, iOS, Windows phone 7 and I believe the new WinRT) can kill inactive application processes under memory pressure. To prevent this from affecting the user experience applications are expected to save and restore their state as their process is killed and restarted. Having application processes killed in this way makes the developers job harder. On various occasions I've seen a mobile app that would: Return to the welcome screen each time I switch back to it. Crash when I switch back to it (possibly accessing some state that no longer exists after the process was killed) Misbehave when I switch back to it (sometimes requiring a restart or tasks killer to fix) Otherwise misbehave in some hard to reproduce way (e.g. android service killed and restarted at the wrong time) I don't really understand why these mobile operating systems are designed to kill tasks in this way especially since it makes application development more difficult and error prone. Desktop operating systems don't kill processes like that. They swap out unused pages of memory to mass storage. Is there a reason why the same approach isn't used on mobile? Mobile hardware is only a few years behind PC hardware in term of performance. I'm sure there are very good reasons why mobile operating systems are designed this way. If you can point me to a paper or blog post that explain these reasons or can give me some insight I'd very much appreciate it.

    Read the article

  • Platform for Efficiency: Boeing Defense, Space & Security integrates supply chain processes using Oracle Business Process Management solutions. by Fred Sandsmark

    - by JuergenKress
    Like most companies, aerospace giant Boeing has its jargon - words and phrases that uniquely define its products and processes. Take the word platform. It is used at Boeing to mean a family of aircraft - the F/A-18 fighter, for example, or the 777 jetliner. Boeing Defense, Space & Security since August 2009, employees in the Global Services & Support (GS&S) division of Boeing Defense, Space & Security have been talking about a different sort of platform: a supply chain technology platform, based on Oracle Business Process Management (Oracle BPM) solutions and Oracle SOA Suite. That platform, built with the assistance of Oracle Diamond Partner Capgemini, is serving as a jumping-off point for Boeing's GS&S staff to deploy radically improved business processes supported by Oracle Fusion Applications to build a high-visibility, end-to-end supply chain. This business process-driven technology platform has ambitious goals: to help GS&S respond more quickly and accurately to its customers' needs, to make business processes at all GS&S sites more consistent and less expensive, and to create a foundation for further improvement and efficiency. Read the full article here. Want to publish your BPM11g success story - request for a partner/customer reference? BPM Center of Excellent & First 100 Days of BPM documents to our SOA Community Workspace MWD_bpm_si_Centre_of_Excellence_0811.pdf First 100 Days of BPM whitepaper.pdf Please visit our SOA Community Workspace (SOA Community membership required). SOA & BPM Partner Community For regular information on Oracle SOA Suite become a member in the SOA & BPM Partner Community for registration please visit  www.oracle.com/goto/emea/soa (OPN account required) If you need support with your account please contact the Oracle Partner Business Center. Blog Twitter LinkedIn Mix Forum Technorati Tags: BPM,BPM reference,BPM Capgemini,BPM first 100 days,BPM center of Excellence,SOA Community,Oracle SOA,Oracle BPM,Community,OPN,Jürgen Kress

    Read the article

  • Windows XP long login (15 minutes +)

    - by Emily Pinkerton
    I'm having a lot of issues with our Windows XP SP3 machines (about 5, but every week another gets on the bandwagon of this issue). They take forever (15 minutes) to apply the user settings once our employee's enter their username and password to login to our domain. It only happens say if a user has reboot the machine and then when they go to log back in then it hangs forever. Reboot and restart are the key words for sure I've noticed with this issue. Here are things I have tested: •Made sure the DNS was set to point to our two servers (Server01 & Server02 are DNS Domain Controllers, 01 is primary and 02 backup). •No major changes have been applied to our network. •All profiles are local, so I have deleted out local profiles that aren't being used on those machines that run slow. •Also I have tried to enable and disable the Enable Fast Login under the local machines GP. It was not configured originally and when I tested both, it made the computer hang on "applying computer settings" for about 15 minutes. When it finally came up to the login screen the it was very quick to login to the domain. However this doesn't fix my issue, and even more frustrating upon setting it back to being not configured it now still takes for forever to apply computer settings. •I enabled the userenv log and here is what I see, but my experience is limited and I'm not sure how to read it exactly. (see below for log, this isn't the whole thing because it's really long) USERENV(2ec.2f0) 10:50:41:843 LoadUserProfile: LoadUserProfileP succeeded USERENV(2ec.2f0) 10:50:41:843 LoadUserProfile: Returning success. Final Information follows: USERENV(2ec.2f0) 10:50:41:843 lpProfileInfo-UserName = USERENV(2ec.2f0) 10:50:41:843 lpProfileInfo-lpProfilePath = < USERENV(2ec.2f0) 10:50:41:843 lpProfileInfo-dwFlags = 0x0 USERENV(2ec.2f0) 10:50:41:843 LoadUserProfile: Returning TRUE. hProfile = <0x818 USERENV(2ec.2f0) 10:50:41:984 IsSyncForegroundPolicyRefresh: Synchronous, Reason:NonCachedCredentials USERENV(2ec.248) 10:50:41:984 IsSyncForegroundPolicyRefresh: Synchronous, Reason:NonCachedCredentials USERENV(3c4.3dc) 10:51:26:166 LibMain: Process Name: C:\WINDOWS\system\wbem\wmiprvse.exe USERENV(2ec.5cc) 11:05:08:741 ProcessGPOs: network name is 192.168.49.0 USERENV(4a8.888) 11:05:08:804 GetProfileType: Profile already loaded. USERENV(4a8.888) 11:05:08:804 LoadProfileInfo: Failed to query central profile with error 2 USERENV(4a8.888) 11:05:08:804 GetProfileType: ProfileFlags is 0 Also this error is in the file quite a lot: USERENV(328.5bc) 11:05:29:733 GetUserDNSDomainName: Failed to impersonate user USERENV(328.834) 11:05:29:733 ImpersonateUser: Failed to impersonate user with 5. I'm really not sure what else to do with my limited experience, but I'm hoping someone can help me. I feel like I'm dealing with an issue way above my level and any knowledge I can gain out of getting this issue fixed would be amazing.

    Read the article

  • Lucene search taking TOOO long.

    - by Josh Handel
    I;m using Lucene.net (2.9.2.2) on a (currently) 70Gig index.. I can do a fairly complicated search and get all the document IDs back in 1 ~ 2 seconds.. But to actually load up all the hits (about 700 thousand in my test queries) takes 5+ minutes. We aren't using lucene for UI, this is a datastore between processes where we have hundreds of millions of pre-cached data elements, and the part I am working on exports a few specific fields from each found document. (ergo, pagination doesn't make since as this is an export between processes). My question is what is the best way to get all of the documents in a search result? currently I am using a custom collector that does a get on the document (with a MapFieldSelector) as its collecting.. I've also tried iterating through the list after the collector has finished.. but that was even worse. I'm open to ideas :-). Thanks in advance.

    Read the article

  • Call to daemon in a /etc/init.d script is blocking, not running in background

    - by tony
    I have a Perl script that I want to daemonize. Basically this perl script will read a directory every 30 seconds, read the files that it finds and then process the data. To keep it simple here consider the following Perl script (called synpipe_server, there is a symbolic link of this script in /usr/sbin/) : #!/usr/bin/perl use strict; use warnings; my $continue = 1; $SIG{'TERM'} = sub { $continue = 0; print "Caught TERM signal\n"; }; $SIG{'INT'} = sub { $continue = 0; print "Caught INT signal\n"; }; my $i = 0; while ($continue) { #do stuff print "Hello, I am running " . ++$i . "\n"; sleep 3; } So this script basically prints something every 3 seconds. Then, as I want to daemonize this script, I've also put this bash script (also called synpipe_server) in /etc/init.d/ : #!/bin/bash # synpipe_server : This starts and stops synpipe_server # # chkconfig: 12345 12 88 # description: Monitors all production pipelines # processname: synpipe_server # pidfile: /var/run/synpipe_server.pid # Source function library. . /etc/rc.d/init.d/functions pname="synpipe_server" exe="/usr/sbin/synpipe_server" pidfile="/var/run/${pname}.pid" lockfile="/var/lock/subsys/${pname}" [ -x $exe ] || exit 0 RETVAL=0 start() { echo -n "Starting $pname : " daemon ${exe} RETVAL=$? PID=$! echo [ $RETVAL -eq 0 ] && touch ${lockfile} echo $PID > ${pidfile} } stop() { echo -n "Shutting down $pname : " killproc ${exe} RETVAL=$? echo if [ $RETVAL -eq 0 ]; then rm -f ${lockfile} rm -f ${pidfile} fi } restart() { echo -n "Restarting $pname : " stop sleep 2 start } case "$1" in start) start ;; stop) stop ;; status) status ${pname} ;; restart) restart ;; *) echo "Usage: $0 {start|stop|status|restart}" ;; esac exit 0 So, (if I have well understood the doc for daemon) the Perl script should run in the background and the output should be redirected to /dev/null if I execute : service synpipe_server start But here is what I get instead : [root@master init.d]# service synpipe_server start Starting synpipe_server : Hello, I am running 1 Hello, I am running 2 Hello, I am running 3 Hello, I am running 4 Caught INT signal [ OK ] [root@master init.d]# So it starts the Perl script but runs it without detaching it from the current terminal session, and I can see the output printed in my console ... which is not really what I was expecting. Moreover, the PID file is empty (or with a line feed only, no pid returned by daemon). Does anyone have any idea of what I am doing wrong ? EDIT : maybe I should say that I am on a Red Hat machine. Scientific Linux SL release 5.4 (Boron) Would it do the job if instead of using the daemon function, I use something like : nohup ${exe} >/dev/null 2>&1 & in the init script ?

    Read the article

  • Shared memory of same DLL in different 32 bit processes is sometimes different in a terminal session

    - by KBrusing
    We have an 32 bit application consisting of some processes. They communicate with shared memory of a DLL used by every process. Shared memory is build with global variables in C++ by "#pragma data_seg ("Shared")". When running this application sometime during starting a new process in addition to an existing (first) process we observe that the shared memory of both processes is not the same. All new started processes cannot communicate with the first process. After stopping all of our processes and restarting the application (with some processes) everything works fine. But sometime or other after successfully starting and finishing new processes the problem occurs again. Running on all other Windows versions or terminal sessions on Windows server 2003 our application never got this problem. Is there any new "feature" on Windows server 2008 that might disturb the hamony of our application?

    Read the article

  • Long Gigabit Ethernet Run

    - by Timothy R. Butler
    I am trying to get an Gig-E network between two buildings that are approximately 260 ft. away. While some TRENDnet switches failed to be able to connect to each other over Cat 6 at that distance, two Netgear 5-port Gig-E switches do so just fine. However, it still fails after I put in place APC PNET1GB ethernet surge protectors at each end before the line connects to the respective switches. So I find myself wondering if I simply need to find a better surge protector that doesn't degrade the signal as much (if so, what kind would you recommend?) or if I should give up on copper and use fiber between the buildings. If I opt to go the latter route, I could really use some pointers. It looks like LC connectors are the most common, but I keep running into some others as well. A media converter on each end seems like the simplest solution, but perhaps a Gig-E switch with an SFP port would make more sense? Given a very limited budget, sticking with my existing copper seems best, but if it is bound to be a headache, a 100 meter fiber cable is something I think I can swing cost wise.

    Read the article

  • MySQL taking a long time to start

    - by Dscoduc
    I'm running Windows Server 2008 with MySQL installed and every time I reboot the server the MySQL Service doesn't start right away. A look into the Windows Eventlog shows that the MySQL Service was hung at startup. Looking at the Services.msc console shows the service state at Starting... Eventually, like 10 minutes, the MySQL Service actually finishes the startup process and the database becomes available for my Wordpress server... I looked at the MySQL .err files and didn't find anything that would indicate a delay in the statup process... Can anyone suggest a way to determine what is causing the delay, and more importantly, how to prevent the delay in the MySQL Startup? UPDATE: Here is the .err log contents from the shutdown to the startup complete. Notice the startup begins at 10:30:00 and the MySQL isn't ready for connections until 10:47:14, a full 17 minutes later: 100322 10:27:06 [Note] C:\Program Files\MySQL\MySQL Server 5.1\bin\mysqld: Normal shutdown 100322 10:27:06 [Note] Event Scheduler: Purging the queue. 0 events 100322 10:27:06 InnoDB: Starting shutdown... 100322 10:27:08 InnoDB: Shutdown completed; log sequence number 4 3854351346 100322 10:27:08 [Warning] Forcing shutdown of 1 plugins 100322 10:27:08 [Note] C:\Program Files\MySQL\MySQL Server 5.1\bin\mysqld: Shutdown complete 100322 10:30:00 [Note] Plugin 'FEDERATED' is disabled. 100322 10:30:01 InnoDB: Started; log sequence number 4 3854351346 100322 10:47:14 [Note] Event Scheduler: Loaded 0 events 100322 10:47:14 [Note] C:\Program Files\MySQL\MySQL Server 5.1\bin\mysqld: ready for connections. UPDATE 2: MySQL is configured as a service (part of the install process, nothing I did) and executes the following syntax (as it appears in the registry): "C:\Program Files\MySQL\MySQL Server 5.1\bin\mysqld" --defaults-file="C:\Program Files\MySQL\MySQL Server 5.1\my.ini" MySQL

    Read the article

  • How can I setup BluePill to Monitor a Rails App Running via Passenger (mod_rails)

    - by Jim Jeffers
    I recently launched a site running phusion passenger. Unfortunately, the site went down due to a frozen thread. I was able to save the server by doing kill -9 to the specific PID. Still though, I thought passenger was able to manage this automatically. I have a server with 1GB of memory running one rails app with passenger allotted up to 7 instances. However, when I came to discover the site went down I found that passenger had spawned 6 instances with one of them using up over 800mb of memory causing the server to swap. As a result I am hoping to setup something like bluepill on the server but I'm slightly confused as to how you go about doing it. Mainly because bluepill expects to start/stop the processes it's monitoring. However, in our case, passenger already restarts processes for us so we only need to monitor the pids of passengers instances and kill them once they've gotten too large. Has anyone here setup BluePill to monitor a rails app running under phusion's passenger? Any insight would be useful.

    Read the article

  • Graphite not running

    - by River
    I'm currently trying to install graphite 0.9.9 on a gentoo box using these instructions from the graphite wiki. Essentially, it fronts graphite using apache and mod_wsgi. Everything seems to have gone well, except that apache / the graphite webapp never seem to return a response to the web browser (the browser continuously waits to load the page). I've turned on the graphite debug info, but the only message in the log files is this, repeated over and over again in info.log (with the pid always changing): Thu Feb 23 01:59:38 2012 :: graphite.wsgi - pid 4810 - reloading search index These instructions have worked for me before to set up graphite on an Ubuntu machine. I suspect that mod_wsgi is dying, but I have confirmed that mod_wsgi works fine when not serving the graphite webapp. This is what my graphite.conf vhost file looks like: WSGISocketPrefix /etc/httpd/wsgi/ <VirtualHost *:80> ServerName # Server name DocumentRoot "/opt/graphite/webapp" ErrorLog /opt/graphite/storage/log/webapp/error.log CustomLog /opt/graphite/storage/log/webapp/access.log common # I've found that an equal number of processes & threads tends # to show the best performance for Graphite (ymmv). WSGIDaemonProcess graphite processes=5 threads=5 display-name='%{GROUP}' inactivity-timeout=120 WSGIProcessGroup graphite WSGIApplicationGroup %{GLOBAL} WSGIImportScript /opt/graphite/conf/graphite.wsgi process-group=graphite application-group=%{GLOBAL} WSGIScriptAlias / /opt/graphite/conf/graphite.wsgi Alias /content/ /opt/graphite/webapp/content/ <Location "/content/"> SetHandler None </Location> # XXX In order for the django admin site media to work you # must change @DJANGO_ROOT@ to be the path to your django # installation, which is probably something like: # /usr/lib/python2.6/site-packages/django Alias /media/ "/usr/lib64/python2.6/site-packages/django/contrib/admin/media/" <Location "/media/"> SetHandler None </Location> # The graphite.wsgi file has to be accessible by apache. It won't # be visible to clients because of the DocumentRoot though. <Directory /opt/graphite/conf/> Order deny,allow Allow from all </Directory> </VirtualHost>

    Read the article

  • How can I setup BluePill to Monitor a Rails App Running via Passenger (mod_rails)

    - by Jim Jeffers
    I recently launched a site running phusion passenger. Unfortunately, the site went down due to a frozen thread. I was able to save the server by doing kill -9 to the specific PID. Still though, I thought passenger was able to manage this automatically. I have a server with 1GB of memory running one rails app with passenger allotted up to 7 instances. However, when I came to discover the site went down I found that passenger had spawned 6 instances with one of them using up over 800mb of memory causing the server to swap. As a result I am hoping to setup something like bluepill on the server but I'm slightly confused as to how you go about doing it. Mainly because bluepill expects to start/stop the processes it's monitoring. However, in our case, passenger already restarts processes for us so we only need to monitor the pids of passengers instances and kill them once they've gotten too large. Has anyone here setup BluePill to monitor a rails app running under phusion's passenger? Any insight would be useful.

    Read the article

  • How to handle multi-processing of libraries which already spawn sub-processes?

    - by exhuma
    I am having some trouble coming up with a good solution to limit sub-processes in a script which uses a multi-processed library and the script itself is also multi-processed. Both, the library and script are modifiable by us. I believe the question is more about design than actual code, but for what it's worth, it's written in Python. The goal of the library is to hide implementation details of various internet routers. For that reason, the library has a "Proxy" factory method which takes the IP of a router as parameter. The factory then probes the device using a set of possible proxies. Usually, there is one proxy which immediately knows that is is able to send commands to this device. All others usually take some time to return (given a timeout). One thought was already to simply query the device for an identifier, and then select the proper proxy using that, but in order to do so, you would already need to know how to query the device. Abstracting this knowledge is one of the main purposes of the library, so that becomes a little bit of a "circular-requirement"/deadlock: To connect to a device, you need to know what proxy to use, and to know what proxy to create, you need to connect to a device. So probing the device is - as we can see - the best solution so far, apart from keeping a lookup-table somewhere. The library currently kills all remaining processes once a valid proxy has been found. And yes, there is always only one good proxy per device. Currently there are about 12 proxies. So if one create a proxy instance using the factory, 12 sub-processes are spawned. So far, this has been really useful and worked very well. But recently someone else wanted to use this library to "broadcast" a command to all devices. So he took the library, and wrote his own multi-processed script. This obviously spawned 12 * n processes where n is the number of IPs to which he broadcasted. This has given us two problems: The host on which the command was executed slowed down to a near halt. Aborting the script with CTRL+C ground the system to a total halt. Not even the hardware console responded anymore! This may be due to some Python strangeness which still needs to be investigated. Maybe related to http://bugs.python.org/issue8296 The big underlying question, is how to design a library which does multi-processing, so other applications which use this library and want to be multi-processed themselves do not run into system limitations. My first thought was to require a pool to be passed to the library, and execute all tasks in that pool. In that way, the person using the library has control over the usage of system resources. But my gut tells me that there must be a better solution. Disclaimer: My experience with multiprocessing is fairly limited. I have implemented a few straightforward which did not require access control to resources. So I have not yet any practical experience with semaphores or mutexes. p.s.: In the future, we may have enough information to do this without the probing. But the database which would contain the proper information is not yet operational. Also, the design about multiprocessing a multiprocessed library intrigues me :)

    Read the article

  • Long pause when accessing DFS namespace

    - by Matt
    We've recently migrated our Windows network to use DFS for shared files. DFS is working well, except for one annoying problem: users experience a significant delay when they try to access a DFS namespace that they have not accessed for some time. I have tried to troubleshoot the issue but have not had any success so far, and I was hoping someone here may have some pointers to help resolve the problem. Firstly, some background on our network: The network uses a Windows 2008 functional level Active Directory domain with two Windows 2008 DCs and two DNS servers (one on each of the DCs). The network is DNS only - no WINS. All computers are located at the same site and connected by Gigabit Ethernet. We have approximately 20 Domain-based DFS namespaces in Windows 2008 mode, and each DFS namespace has two Windows 2008 DFS namespace servers (the same two servers for all namespaces). All namespace servers are in FQDN mode and all folder targets are specified using their FQDN. All computers are up-to-date with Service Packs and patches. The actual folder targets (i.e. the SMB shares our DFS folders point to) are scattered across several file and application servers, all running Windows 2008 bar two application servers which run Windows 2003 R2, with no replication setup at all (e.g. all DFS folders currently only have one folder target). Some more detail on the problem: The namespace access delay is generally 1 - 10 seconds long and seems to occur when a particular computer has not accessed the requested namespace for approximately five minutes or more. For example, if the user has not accessed \\domain.name\namespace1\ for more than five minutes and attempts to access \\domain.name\namespace1\ via Windows Explorer, the Explorer window will freeze for 1 - 10 seconds before finally resuming and displaying the folders that exist in \\domain.name\namespace1. If they then close the Explorer window and attempt to access \\domain.name\namespace1\ again within five minutes the contents will be displayed almost instantly - if they wait longer than five minutes it will go through the 1 - 10 second pause again. Once "inside" the namespace everything is nice and snappy, it's just the initial connection to the namespace that is slow. The browsing delays seem to affect all variants of Windows that we use (Windows 2008 x64 SP2, Windows 2003 R2 x86 SP2, Windows XP Pro x86 SP3) - it is possibly a bit worse in Windows XP / 2003 than in Windows 2008, but I'm not sure if the difference isn't just psychological. Accessing the underlying folder targets directly exhibits no delay at all - i.e. if the SMB shares pointed to by DFS are accessed directly (bypassing DFS) then there is no pause. During trouble-shooting I noticed that the "Cache duration" for all of our DFS roots is set to 300 seconds - 5 minutes. Given that this is the same amount of time required to trigger the pause I assume that this caching is somehow related, although I am unsure exactly what is cached on the client and hence what needs to be looked up again after 5 minutes have elapsed. In trying to resolve the problem I have already tried / checked the following (without success): Run dcdiag on both Domain Controllers - no problems found Done some basic DNS server checks without finding any problems - I don't know how to check the DNS servers in detail, but I would add that the network is not exhibiting any other strange behavior that may point to a DNS problem Disabled Anti-virus on clients and servers Removing one of the namespace servers from a couple of namespaces - no difference So that's where I'm up to - and I'm out of ideas. Can anyone suggest what may be causing the delays and/or what I should be trying next?

    Read the article

  • smartctl -t long isn't finishing

    - by xenoterracide
    I been running smartctl -t long on a drive for about 2 days now and it seems to be stalled at 10%. short and conveyance both passed. I have to send 1 of 2 drives purchased back I found badblocks with badblocks (none on this drive and I'ts made over a pass already). I'm just wondering if I should be concerned about this. smartctl 5.39.1 2010-01-28 r3054 [x86_64-unknown-linux-gnu] (local build) Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net === START OF INFORMATION SECTION === Device Model: WDC WD10EARS-00Y5B1 Serial Number: WD-WMAV51582123 Firmware Version: 80.00A80 User Capacity: 1,000,204,886,016 bytes Device is: Not in smartctl database [for details use: -P showall] ATA Version is: 8 ATA Standard is: Exact ATA specification draft version not indicated Local Time is: Mon May 10 22:19:52 2010 EDT SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x82) Offline data collection activity was completed without error. Auto Offline Data Collection: Enabled. Self-test execution status: ( 241) Self-test routine in progress... 10% of test remaining. Total time to complete Offline data collection: (20100) seconds. Offline data collection capabilities: (0x7b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 231) minutes. Conveyance self-test routine recommended polling time: ( 5) minutes. SCT capabilities: (0x3031) SCT Status supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x002f 200 200 051 Pre-fail Always - 2 3 Spin_Up_Time 0x0027 131 131 021 Pre-fail Always - 6408 4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 12 5 Reallocated_Sector_Ct 0x0033 200 200 140 Pre-fail Always - 0 7 Seek_Error_Rate 0x002e 200 200 000 Old_age Always - 0 9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 148 10 Spin_Retry_Count 0x0032 100 253 000 Old_age Always - 0 11 Calibration_Retry_Count 0x0032 100 253 000 Old_age Always - 0 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 10 192 Power-Off_Retract_Count 0x0032 200 200 000 Old_age Always - 7 193 Load_Cycle_Count 0x0032 200 200 000 Old_age Always - 174 194 Temperature_Celsius 0x0022 106 102 000 Old_age Always - 41 196 Reallocated_Event_Count 0x0032 200 200 000 Old_age Always - 0 197 Current_Pending_Sector 0x0032 200 200 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0030 200 200 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x0032 200 200 000 Old_age Always - 0 200 Multi_Zone_Error_Rate 0x0008 200 200 000 Old_age Offline - 0 SMART Error Log Version: 1 No Errors Logged SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Conveyance offline Completed without error 00% 99 - # 2 Extended offline Interrupted (host reset) 10% 30 - # 3 Short offline Completed without error 00% 0 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay.

    Read the article

  • ActionScript/Flex ArrayCollection of Number objects to Java Collection<Long> using BlazeDS

    - by Justin
    Hello, I am using Flex 3 and make a call through a RemoteObject to a Java 1.6 method and exposed with BlazeDS and Spring 2.5.5 Integration over a SecureAMFChannel. The ActionScript is as follows (this code is an example of the real thing which is on a separate dev network); import com.adobe.cairngorm.business.ServiceLocator; import mx.collections.ArrayCollection; import mx.rpc.remoting.RemoteObject; import mx.rpc.IResponder; public class MyClass implements IResponder { private var service:RemoteObject = ServiceLocator.getInstance().getRemoteOjbect("mySerivce"); public MyClass() { [ArrayElementType("Number")] private var myArray:ArrayCollection; var id1:Number = 1; var id2:Number = 2; var id3:Number = 3; myArray = new ArrayCollection([id1, id2, id3]); getData(myArray); } public function getData(myArrayParam:ArrayCollection):void { var token:AsyncToken = service.getData(myArrayParam); token.addResponder(this.responder); //Assume responder implementation method exists and works } } This will make a call, once created to the service Java class which is exposed through BlazeDS (assume the mechanics work because they do for all other calls not involving Collection parameters). My Java service class looks like this; public class MySerivce { public Collection<DataObjectPOJO> getData(Collection<Long> myArrayParam) { //The following line is never executed and throws an exception for (Long l : myArrayParam) { System.out.println(l); } } } The exception that is thrown is a ClassCastException saying that a java.lang.Integer cannot be cast to a java.lang.Long. I worked around this issue by looping through the collection using Object instead, checking to see if it is an Integer, cast it to one, then do a .longValue() on it then add it to a temp ArraList. Yuk. The big problem is my application is supposed to handle records in the billions from a DB and the id will overflow the 2.147 billion limit of an integer. I would love to have BlazeDS or the JavaAdapter in it, translate the ActionScript Number to a Long as specified in the method. I hate that even though I use the generic the underlying element type of the collection is an Integer. If this was straight Java, it wouldn't compile. Any ideas are appreciated. Solutions are even better! :)

    Read the article

  • How to cancel a long running WCF requests from silverlight 3

    - by Kim
    I have a silverlight 3 application that makes several long running requests to a WCF service. While these calls are in progress, any other later WCF calls are queued by silverlight 3 because it will only do two requests at the same time, thus making the application suck :( How can I cancel the long running blocking requests?

    Read the article

< Previous Page | 38 39 40 41 42 43 44 45 46 47 48 49  | Next Page >