Search Results

Search found 2513 results on 101 pages for 'scott ryan'.

Page 44/101 | < Previous Page | 40 41 42 43 44 45 46 47 48 49 50 51  | Next Page >

  • Issues with mx:method, mx.rpc.remoting.mxml.RemoteObject, and sub-classing mx.rpc.remoting.mxml.Remo

    - by Ryan Wilson
    I am looking to subclass RemoteObject. Instead of: <mx:RemoteObject ... > <mx:method ... /> <mx:method ... /> </mx:RemoteObject> I want to do something like: <remoting:CustomRemoteObject ...> <mx:method ... /> <mx:method ... /> </remoting:CustomRemoteObject> where CustomRemoteObject extends mx.rpc.remoting.mxml.RemoteObject like so: package remoting { import mx.rpc.remoting.mxml.RemoteObject; public class CustomRemoteObject extends RemoteObject { public function CustomRemoteObject(destination:String=null) { super(destination); } } } However, when doing so and declaring a CustomRemoteObject in MXML as above, the flex compiler shows the error: Could not resolve <mx:method> to a component implementation At first I thought it had something to do with CustomRemoteObject failing to do something, despite that (or since) it had no change except as to the name. So, I copied the source from mx.rpc.remoting.mxml.RemoteObject into CustomRemoteObject and modified it so the only difference was a refactoring of the class and package name. But still, the same error. Unlike many MXML components, I cannot cmd+click <mx:method> in FlashBuilder to open the source. Likewise, I have not found a reference in mx.rpc.remoting.mxml.RemoteObject, mx.rpc.remoting.RemoteObject, or mx.rpc.remoting.AbstractService, and have been unsuccessful in find its source online. Which leads me to the questions in the title: What exactly is <mx:method>? (yes, I know it's a declaration of a RemoteObject method, and I know how to use it, but it's peculiar in regard to other components) Why did my attempt at subclassing RemoteObject fail, despite it effectually being a rename? Perhaps the root, why can mx.rpc.remoting.mxml.RemoteObject as an MXML declaration accept <mx:method> child tags, yet the source of said class cannot when refactored in name only?

    Read the article

  • VS2010 method comment block pretty format.

    - by camelCase
    I have just installed the lastest RC of VS2010, which for me represents a shift from VS2008. A new comment formatting feature that I was looking forward to appears to be missing. About 6 months ago I read a Scott Gu blog post that mentioned a new VS2010 feature that would format /// style method comment blocks into more readable formatted regions inline with other code. The Scott Gu blog did not provide a screen shot but I was expecting the VS2010 editor to remove the XML tags from the /// method comment block and render just the essential text comment. Was this feature pulled during the Beta, or is there an option switch urking somewhere?

    Read the article

  • Jquery getJSON populate select menu question...

    - by Scott
    I am populating a select menu with getJSON. I am wondering if there's a way that I can use jQuery's .each function to bring in these values? Surely there must be an easier way to accomplish this...maybe? PHP file: <?php $queryMonth = "SELECT monthID, month FROM months"; $result = $db->query($queryMonth); while($rowMonth = $db->fetch_assoc($result)) : $data[] = $rowMonth; endwhile; echo json_encode($data); ?> The jQuery: $.getJSON('selectMenus.php', function(data){ $("select.month").append("<option value=" + data[0].monthID + ">" + data[0].month + "</option>"); $("select.month").append("<option value=" + data[1].monthID + ">" + data[1].month + "</option>"); $("select.month").append("<option value=" + data[2].monthID + ">" + data[2].month + "</option>"); $("select.month").append("<option value=" + data[3].monthID + ">" + data[3].month + "</option>"); $("select.month").append("<option value=" + data[4].monthID + ">" + data[4].month + "</option>"); $("select.month").append("<option value=" + data[5].monthID + ">" + data[5].month + "</option>"); $("select.month").append("<option value=" + data[6].monthID + ">" + data[6].month + "</option>"); $("select.month").append("<option value=" + data[7].monthID + ">" + data[7].month + "</option>"); $("select.month").append("<option value=" + data[8].monthID + ">" + data[8].month + "</option>"); $("select.month").append("<option value=" + data[9].monthID + ">" + data[9].month + "</option>"); $("select.month").append("<option value=" + data[10].monthID + ">" + data[10].month + "</option>"); $("select.month").append("<option value=" + data[11].monthID + ">" + data[11].month + "</option>"); }); my json output looks like this: [{"monthID":"1","month":"January"},{"monthID":"2","month":"February"},{"monthID":"3","month":"March"},{"monthID":"4","month":"April"},{"monthID":"5","month":"May"},{"monthID":"6","month":"June"},{"monthID":"7","month":"July"},{"monthID":"8","month":"August"},{"monthID":"9","month":"Septemeber"},{"monthID":"10","month":"October"},{"monthID":"11","month":"November"},{"monthID":"12","month":"December"}]

    Read the article

  • What is the email subject length limit?

    - by Scott Ferguson
    How many characters are allowed to be in the subject line of Internet email? I had a scan of The RFC for email but could not see specifically how long it was allowed to be. I have a colleague that wants to programmatically validate for it. If there is no formal limit, what is a good length in practice to suggest? Cheers,

    Read the article

  • How can I tell if a set of parens in perl code will act as grouping parens or form a list?

    - by Ryan Thompson
    In perl, parentheses are used for overriding precedence (as in most programming languages) as well as for creating lists. How can I tell if a particular pair of parens will be treated as a grouping construct or a one-element list? For example, I'm pretty sure this is a scalar and not a one-element list: (1 + 1) But what about more complex expressions? Is there an easy way to tell?

    Read the article

  • Are there clean ways to do these Quartz Triggers?

    - by Ryan Elkins
    I'm using Quartz to schedule some jobs but I have a few scenarios that I'm not sure how to resolve. 1) Lets say I have a job that is scheduled to run every 5 minutes. Generally that works well but periodically the job takes more than 5 minutes and I don't really want multiple instances of the job running simultaneously. 2) I have a job that can take between 1 and 60 minutes to complete. I want it to run continuously but pause for 10 minutes between runs, regardless of how long it took previously. I like using Quartz for this rather than some sort of loop because if a job crashes Quartz will still spin up a new one based on the schedule. I am using Quartz in Java right now.

    Read the article

  • Linked List Design

    - by Jim Scott
    The other day in a local .NET group I attend the following question came up: "Is it a valid interview question to ask about Linked Lists when hiring someone for a .NET development position?" Not having a computer sciense degree and being a self taught developer my response was that I did not feel it was appropriate as I in 5 years of developer with .NET had never been exposed to linked lists and did not hear any compeling reason for a use for one. However the person commented that it is a very common interview question so I decided when I left that I would do some reasearch on linked lists and see what I might be missing. I have read a number of posts on stack overflow and various google searches and decided the best way to learn about them was to write my own .NET classes to see how they worked from the inside out. Here is my class structure Single Linked List Constructor public SingleLinkedList(object value) Public Properties public bool IsTail public bool IsHead public object Value public int Index public int Count private fields not exposed to a property private SingleNode firstNode; private SingleNode lastNode; private SingleNode currentNode; Methods public void MoveToFirst() public void MoveToLast() public void Next() public void MoveTo(int index) public void Add(object value) public void InsertAt(int index, object value) public void Remove(object value) public void RemoveAt(int index) Questions I have: What are typical methods you would expect in a linked list? What is typical behaviour when adding new records? For example if I have 4 nodes and I am currently positioned in the second node and perform Add() should it be added after or before the current node? Or should it be added to the end of the list? Some of the designs I have seen explaining things seem to expose outside of the LinkedList class the Node object. In my design you simply add, get, remove values and know nothing about any node object. Should the Head and Tail be placeholder objects that are only used to define the head/tail of the list? I require my Linked List be instantiated with a value which creates the first node of the list which is essentially the head and tail of the list. Would you change that ? What should the rules be when it comes to removing nodes. Should someone be able to remove all nodes? Here is my Double Linked List Constructor public DoubleLinkedList(object value) Properties public bool IsHead public bool IsTail public object Value public int Index public int Count Private fields not exposed via property private DoubleNode currentNode; Methods public void AddFirst(object value) public void AddLast(object value) public void AddBefore(object existingValue, object value) public void AddAfter(object existingValue, object value) public void Add(int index, object value) public void Add(object value) public void Remove(int index) public void Next() public void Previous() public void MoveTo(int index)

    Read the article

  • Is anyone else experiencing weird debug + crash behavior with Silverlight?

    - by Scott Barnes
    I have noticed that after awhile of debug/tweakcode/debug etc that eventually Silverlight starts to crash all of my browsers (i.e. doesn't matter which i fire, they all just crash). If i then go to a site that has Silverlight, it works fine? so it has something to do with debugger + Silverlight not getting along? I then reboot and the problem goes away? Is anyone else experiencing this kind of weird behaviour? I have noticed though that if i put breakpoints on the code they all seem to halt, in that it appears that it can instantiate the said .xap etc ok, but just can't seem to render it to screen without a crash? (There's nothing in the log files and i've tried to attach a seperate VS2008 instance to both IE, Devenv and Blend etc trying to see if i can catch what's causing this to occur?)

    Read the article

  • Rhino and Javascript 1.8?

    - by Scott
    Is it possible to have Rhino use a newer implementation of JS than 1.7? Do we have to wait for mozilla to do this, or is there a community project that has taken the lead? Thanks.

    Read the article

  • MSBuild - setting a reference path

    - by Ryan
    I have several assemblies my project is dependant upon. These are stored in the Project's directory under the "Dependencies" folder. So something like this. Solution - Project - Dependancies FunkyAssembly.dll - bin - Debug - Release SomeCode.cs I've referenced FunkyAssembly.dll using Browse and in project.csproj I see <Reference Include="FunkyAssembly"> <HintPath>Dependancies\FunkyAssembly.dll</HintPath> </Reference> So far so good - except after a release build FunkyAssembly.dll is copied to the Release directory (not a problem in itself) but then future debug builds will reference this copy rather than the copy in Dependencies. You can see this if you at Path in the reference properties. This means that if Dependencies\FunkyAssembly.dll is updated the build won't pick it up as its referencing the old copy in bin/Release. Any way to FORCE the damn thing to pick up Dependencies\FunkyAssembly.dll rather than HINT?

    Read the article

  • Coding solution to WAR installation error (Websphere Portal 6.0) ?

    - by Scott Leis
    I have a Websphere Portal application containing several portlets for which I'm currently working on some changes. A week ago, the WAR file produced by Rational Application Developer could be installed on the Portal server with no problems. Yesterday I made some seemingly minor changes to two JSP files and their associated "pagecode" Java files, and attempting to update the WAR on the server (using the Portal Administration web interface) now produces an error message. The WAR upload works, and the system shows me the correct list of portlets in the WAR file, but clicking "Finish" gives me a page with the error message "EJPAQ1319E: Cannot install the selected WAR file. View Details". Clicking the "View Details" link gives me a page with the following text: EJPAQ1319E: Cannot install the selected WAR file. com.ibm.portal.WpsException: EJPAQ1319E: Cannot install the selected WAR file. at com.ibm.wps.portlets.portletmanager.actions.DoInstallWebModuleAction.installPortletFromFormFile(DoInstallWebModuleAction.java:633) at com.ibm.wps.portlets.portletmanager.actions.DoInstallWebModuleAction.doExecute(DoInstallWebModuleAction.java:159) at com.ibm.wps.portlets.adminstruts.actions.BaseAction.execute(BaseAction.java:64) at com.ibm.wps.portlets.struts.WpsRequestProcessor.processActionPerform(WpsRequestProcessor.java:338) at org.apache.struts.action.RequestProcessor.process(RequestProcessor.java:274) at com.ibm.wps.portlets.struts.WpsStrutsPortlet.processActionPerformed(WpsStrutsPortlet.java:1947) at com.ibm.wps.portlets.struts.WpsStrutsPortlet.actionPerformed(WpsStrutsPortlet.java:1637) at com.ibm.wps.portlets.adminstruts.WpsAdminStrutsPortlet.actionPerformed(WpsAdminStrutsPortlet.java:261) at com.ibm.wps.pe.pc.legacy.SPIPortletInterceptorImpl.handleEvents(SPIPortletInterceptorImpl.java:323) EJPPE0020E: It is not allowed to install a JSR 168 compliant over a 4.x portlet application. com.ibm.wps.command.applications.AppWarFileException: EJPPE0020E: It is not allowed to install a JSR 168 compliant over a 4.x portlet application. WrappedException is: com.ibm.wps.pe.mgr.exceptions.InvalidWarFileException: EJPPE0020E: It is not allowed to install a JSR 168 compliant over a 4.x portlet application. at com.ibm.wps.command.applications.AbstractApplicationsCommand.throwAppMgrException(AbstractApplicationsCommand.java:492) at com.ibm.wps.command.applications.UpdatePortletApplicationCommand.execute(UpdatePortletApplicationCommand.java:165) at com.ibm.wps.portlets.portletmanager.actions.DoInstallWebModuleAction.installPortletFromFormFile(DoInstallWebModuleAction.java:510) at com.ibm.wps.portlets.portletmanager.actions.DoInstallWebModuleAction.doExecute(DoInstallWebModuleAction.java:159) at com.ibm.wps.portlets.adminstruts.actions.BaseAction.execute(BaseAction.java:64) at com.ibm.wps.portlets.struts.WpsRequestProcessor.processActionPerform(WpsRequestProcessor.java:338) at org.apache.struts.action.RequestProcessor.process(RequestProcessor.java:274) at com.ibm.wps.portlets.struts.WpsStrutsPortlet.processActionPerformed(WpsStrutsPortlet.java:1947) EJPPE0020E: It is not allowed to install a JSR 168 compliant over a 4.x portlet application. com.ibm.wps.pe.mgr.exceptions.InvalidWarFileException: EJPPE0020E: It is not allowed to install a JSR 168 compliant over a 4.x portlet application. at com.ibm.wps.pe.mgr.AbstractApplicationManagerImpl.updateWebModule(AbstractApplicationManagerImpl.java:1338) at com.ibm.wps.pe.mgr.AbstractApplicationManagerImpl.updateWebModule(AbstractApplicationManagerImpl.java:1255) at com.ibm.wps.command.applications.UpdatePortletApplicationCommand.execute(UpdatePortletApplicationCommand.java:135) at com.ibm.wps.portlets.portletmanager.actions.DoInstallWebModuleAction.installPortletFromFormFile(DoInstallWebModuleAction.java:510) at com.ibm.wps.portlets.portletmanager.actions.DoInstallWebModuleAction.doExecute(DoInstallWebModuleAction.java:159) at com.ibm.wps.portlets.adminstruts.actions.BaseAction.execute(BaseAction.java:64) at com.ibm.wps.portlets.struts.WpsRequestProcessor.processActionPerform(WpsRequestProcessor.java:338) at org.apache.struts.action.RequestProcessor.process(RequestProcessor.java:274) at com.ibm.wps.portlets.struts.WpsStrutsPortlet.processActionPerformed(WpsStrutsPortlet.java:1947) All I've been able to find about this error via Google is the following in the Websphere Portal documentation: EJPPE0020E: It is not allowed to install a {0} over a {1} portlet application. Explanation: A portlet application containing legacy portlets can only be updated with another portlet application that contains legacy portlets. The same is true for standard portlet applications. User Response: Modify the portlet.xml of the application such that it matches the original API type, standard or legacy and try again. However, the "portlet.xml" file has not changed in about a month, and I've done several WAR updates for this application in that time with no problems. The problem seems to be caused by the code changes I did yesterday, but I have no clue why a few lines of code would do this. Any ideas?

    Read the article

  • C# Linq Entity Conversion Error on Nonexistent Value?

    - by Ryan
    While trying to query some data using the Linq Entity Framework I'm receiving the following exception: {"Conversion failed when converting the varchar value '3208,7' to data type int."} The thing that is confusing is that this value does not even exist in the view I am querying from. It does exist in the table the view is based on, however. The query I'm running is the following: return context.vb_audit_department .Where(x => x.department_id == department_id && x.version_id == version_id) .GroupBy(x => new { x.action_date, x.change_type, x.user_ntid, x.label }) .Select(x => new { action_date = x.Key.action_date, change_type = x.Key.change_type, user_ntid = x.Key.user_ntid, label = x.Key.label, count = x.Count(), items = x }) .OrderByDescending(x => x.action_date) .Skip(startRowIndex) .Take(maximumRows) .ToList(); Can somebody explain why LINQ queries the underlying table instead of the actual view, and if there is any way around this behavior?

    Read the article

  • Cascade Saves with Fluent NHibernate AutoMapping

    - by Ryan Montgomery
    How do I "turn on" cascading saves using AutoMap Persistence Model with Fluent NHibernate? As in: I Save the Person and the Arm should also be saved. Currently I get "object references an unsaved transient instance - save the transient instance before flushing" public class Person : DomainEntity { public virtual Arm LeftArm { get; set; } } public class Arm : DomainEntity { public virtual int Size { get; set; } } I found an article on this topic, but it seems to be outdated.

    Read the article

  • binary sed replacement

    - by Ryan
    Hello, I was attempting to do a sed replacement in a binary file however I am beginning to believe that is not possible. Essentially what I wanted to do was similar to the following: sed -bi "s/\(\xFF\xD8[[:xdigit:]]\{1,\}\xFF\xD9\)/\1/" file.jpg Or more notably... scan through a binary file until the hex code FFD8, continue reading until FFD9, and only save what was between them (discards the junk before and after, but saves FFD8 and FFD9 as part of the file still) Is there a good way to do this? Even if not using sed?

    Read the article

  • JUnit tests for POJOs

    - by Ryan Thames
    I work on a project where we have to create unit tests for all of our simple beans (POJOs). Is there any point to creating a unit test for POJOs if all they consist of is getters and setters? Is it a safe assumption to assume POJOs will work about 100% of the time? Duplicate of - Should @Entity Pojos be tested? See also Is it bad practice to run tests on a DB instead of on fake repositories? Is there a Java unit-test framework that auto-tests getters and setters?

    Read the article

  • MS Access Interop - How to set print filename?

    - by Ryan
    Hi all, I'm using Delphi 2009 and the MS Access Interop COM API. I'm trying to figure out two things, but one is more important than the other right now. I need to know how to set the file name when sending the print job to the spooler. Right now it's defaulting to the Access DB's name, which can be something different than the file's name. I need to just ensure that when this is printed it enters the print spool using the same filename as the actual file itself - not the DB's name. My printer spool is actually a virtual print driver that converts documents to an image. That's my main issue. The second issue is how to specify which printer to use. This is less important at the moment because I'm just using the default printer for now. It would be nice if I could specify the printer to use, though. Does anyone know either of these two issues? Thank you in advance. I'll go ahead and paste my code: unit Converter.Handlers.Office.Access; interface uses sysutils, variants, Converter.Printer, Office_TLB, Access_TLB, UDC_TLB; procedure ToTiff(p_Printer: PrinterDriver; p_InputFile, p_OutputFile: String); implementation procedure ToTiff(p_Printer: PrinterDriver; p_InputFile, p_OutputFile: String); var AccessApp : AccessApplication; begin AccessApp := CoAccessApplication.Create; AccessApp.Visible := False; try AccessApp.OpenCurrentDatabase(p_InputFile, True, ''); AccessApp.RunCommand(acCmdQuickPrint); AccessApp.CloseCurrentDatabase; finally AccessApp.Quit(acQuitSaveNone); end; end; end.

    Read the article

  • Create a table of contents from a pdf file

    - by ryan
    I'm using quartz to display pdf content, and I need to create a table of contents to navigate through the pdf. From reading Apple's documentation I think I am supposed to use CGPDFDocumentGetCatalog, but I can't find any examples on how to use this anywhere. Any ideas?

    Read the article

  • Is it possible to have mspec & NUnit tests in a single project

    - by Mike Scott
    I've got a unit test project using NUnit. When I add the mspec (machine.specifications) assembly to the references, both ReSharper and TestDriven.Net stop running the NUnit tests and only run the mspec tests. Is there a way or setting that allows both NUnit & mspec tests to co-exist and run in the same project using R# & TD.Net test runners?

    Read the article

  • Internet Explorer ajax request not returning anything

    - by Ryan Giglio
    At the end of my registration process you get to a payment screen where you can enter a coupon code, and there is an AJAX call which fetches the coupon from the database and returns it to the page so it can be applied to your total before it is submitted to paypal. It works great in Firefox, Chrome, and Safari, but in Internet Explorer, nothing happens. The (data) being returned to the jQuery function appears to be null. jQuery Post function applyPromo() { var enteredCode = $("#promoCode").val(); $(".promoDiscountContainer").css("display", "block"); $(".promoDiscount").html("<img src='/images/loading.gif' alt='Loading...' title='Loading...' height='18' width='18' />"); $.post("/ajax/lookup-promo.php", { promoCode : enteredCode }, function(data){ if ( data != "error" ) { var promoType = data.getElementsByTagName('promoType').item(0).childNodes.item(0).data; var promoAmount = data.getElementsByTagName('promoAmount').item(0).childNodes.item(0).data; $(".promoDiscountContainer").css("display", "block"); $(".totalWithPromoContainer").css("display", "block"); if (promoType == "percent") { $("#promoDiscount").html("-" + promoAmount + "%"); var newPrice = (originalPrice - (originalPrice * (promoAmount / 100))); $("#totalWithPromo").html(" $" + newPrice); if ( promoAmount == 100 ) { skipPayment(); } } else { $("#promoDiscount").html("-$" + promoAmount); var newPrice = originalPrice - promoAmount; $("#totalWithPromo").html(" $" + newPrice); } $("#paypalPrice").val(newPrice + ".00"); $("#promoConfirm").css("display", "none"); $("#promoConfirm").html("Promotion Found"); finalPrice = newPrice; } else { $(".promoDiscountContainer").css("display", "none"); $(".totalWithPromoContainer").css("display", "none"); $("#promoDiscount").html(""); $("#totalWithPromo").html(""); $("#paypalPrice").val(originalPrice + ".00"); $("#promoConfirm").css("display", "block"); $("#promoConfirm").html("Promotion Not Found"); finalPrice = originalPrice; } }, "xml"); } Corresponding PHP Page include '../includes/dbConn.php'; $enteredCode = $_POST['promoCode']; $result = mysql_query( "SELECT * FROM promotion WHERE promo_code = '" . $enteredCode . "' LIMIT 1"); $currPromo = mysql_fetch_array( $result ); if ( $currPromo ) { if ( $currPromo['percent_off'] != "" ) { header("content-type:application/xml;charset=utf-8"); echo "<?xml version=\"1.0\" encoding=\"UTF-8\" standalone=\"yes\"?>"; echo "<promo>"; echo "<promoType>percent</promoType>"; echo "<promoAmount>" . $currPromo['percent_off'] . "</promoAmount>"; echo "</promo>"; } else if ( $currPromo['fixed_off'] != "") { header("content-type:application/xml;charset=utf-8"); echo "<?xml version=\"1.0\" encoding=\"UTF-8\" standalone=\"yes\"?>"; echo "<promo>"; echo "<promoType>fixed</promoType>"; echo "<promoAmount>" . $currPromo['fixed_off'] . "</promoAmount>"; echo "</promo>"; } } else { echo "error"; } When I run the code in IE, I get a javascript error on the Javascript line that says var promoType = data.getElementsByTagName('promoType').item(0).childNodes.item(0).data; Here's a screenshot of the IE debugger

    Read the article

  • Are there any command line tools for controllable XML formatting?

    - by Scott Stafford
    Hi - I am searching for a command-line tool (or XSLT technique, or C# code that can be made into a command-line tool, etc) for Windows that will do XML pretty-printing. Specifically, I want one that has the ability to put attributes one-to-a-line, something like: <Node> <ChildNode value1='5' value2='6' value3='happy' /> </Node> It doesn't have to be EXACTLY like that, but I want to use it for an XML file that has nodes with dozens of attributes and spreading them across multiple lines makes them easier to read, edit, and text-diff.

    Read the article

  • Simple Expand/Collapse divs > JQuery?

    - by Scott B
    I need to add some accordian style expand/collapse handles to a series of parent container divs in my application. Is this something that's too simple for a library like jquery? Example: <div class="handleDiv"> expand | collapse <div>child element</div> <div>child element</div> </div> <div class="handleDiv"> expand | collapse <div>child element</div> <div>child element</div> </div>

    Read the article

  • MYSQL OR vs IN performance

    - by Scott
    I am wondering if there is any difference in regards to performance between the following SELECT ... FROM ... WHERE someFIELD IN(1,2,3,4) SELECT ... FROM ... WHERE someFIELD between 0 AND 5 SELECT ... FROM ... WHERE someFIELD = 1 OR someFIELD = 2 OR someFIELD = 3 ... or will MySQL optimize the SQL in the same way compilers will optimize code ? EDIT: Changed the AND's to OR's for the reason stated in the comments.

    Read the article

< Previous Page | 40 41 42 43 44 45 46 47 48 49 50 51  | Next Page >