Search Results

Search found 108959 results on 4359 pages for 'ado net data services'.

Page 49/4359 | < Previous Page | 45 46 47 48 49 50 51 52 53 54 55 56  | Next Page >

  • ASP.NET MVC tries to load older version of Owin assembly

    - by d_mcg
    As a bit of context, I'm developing an ASP.NET MVC 5 application that uses OAuth-based authentication via Microsoft's OWIN implementation, for Facebook and Google only at this stage. Currently (as of v3.0.0, git-commit 4932c2f), the FacebookAuthenticationOptions and GoogleOAuth2AuthenticationOptions don't provide any property to force Facebook nor Google respectively to reauthenticate users (via appending the appropriate query string parameters) when signing in. Initially, I set out to override the following classes: FacebookAuthenticationOptions GoogleOAuth2AuthenticationOptions FacebookAuthenticationHandler (specifically AuthenticateCoreAsync()) GoogleOAuth2AuthenticationHandler (specifically AuthenticateCoreAsync()) yet discovered that the ~AuthenticationHandler classes are marked as internal. So I pulled a copy of the source for the Katana project (http://katanaproject.codeplex.com/) and modified the source accordingly. After compiling, I found that there are several dependencies that needed updating in order to use these updated assemblies (Microsoft.Owin.Security.Facebook and Microsoft.Owin.Security.Google) in the MVC project: Microsoft.Owin Microsoft.Owin.Security Microsoft.Owin.Security.Cookies Microsoft.Owin.Security.OAuth Microsoft.Owin.Host.SystemWeb This was done by replacing the existing project references to the 3.0.0 versions and updating those in web.config. Good news: the project compiles successfully. In debugging, I received an exception on startup: An exception of type 'System.IO.FileLoadException' occurred in [MVC web assembly].dll but was not handled in user code Additional information: Could not load file or assembly 'Microsoft.Owin.Security, Version=3.0.0.0, Culture=neutral, PublicKeyToken=31bf3856ad364e35' or one of its dependencies. The located assembly's manifest definition does not match the assembly reference. (Exception from HRESULT: 0x80131040) The underlying exception indicated that Microsoft.AspNet.Identity.Owin was trying to load v2.1.0 of Microsoft.Owin.Security when calling app.UseExternalSignInCookie() from Startup.ConfigureAuth(IAppBuilder app) in Startup.Auth.cs. Unfortunately that assembly (and its other dependency, Microsoft.AspNet.Identity.Owin) aren't part of the Project Katana solution, and I can't find any accessible repository for these assemblies online. Are the Microsoft.AspNet.Identity assemblies open source, like the Katana project? Is there a way to fool those assemblies to use the referenced v3.0.0 assemblies instead of v2.1.0? The /bin folder contains the 3.0.0 versions of the Owin assemblies. I've upgraded the NuGet packages for Microsoft.AspNet.Identity.Owin, and this is still an issue. Any ideas on how to resolve this issue?

    Read the article

  • Html.DropDownListFor<> and complex object in ASP.NET MVC2

    - by dagda1
    Hi, I am looking at ASP.NET MVC2 and trying to post a complex object using the new EditorFor syntax. I have a FraudDto object that has a FraudCategory child object and I want to set this object from the values that are posted from the form. Posting a simple object is not a problem but I am struggling with how to handle complex objects with child objects. I have the following parent FraudDto object whcih I am binding to on the form: public class FraudDto { public FraudCategoryDto FraudCategory { get; set; } public List<FraudCategoryDto> FraudCategories { get; private set; } public IEnumerable<SelectListItem> FraudCategoryList { get { return FraudCategories.Select(t => new SelectListItem { Text = t.Name, Value = t.Id.ToString() }); } The child FraudCategoryDto object looks like this: public class FraudCategoryDto { public int Id { get; set; } public string Name { get; set; } } On the form, I have the following code where I want to bind the FraudCategoryDto to the dropdown. The view is of type ViewPage: <td class="tac"> <strong>Category:</strong> </td> <td> <%= Html.DropDownListFor(x => x.FraudCategory, Model.FraudTypeList)%> </td> I then have the following controller code: [HttpPost] public virtual ViewResult SaveOrUpdate(FraudDto fraudDto) { return View(fraudDto); } When the form is posted to the server, the FraudCategory property of the Fraud object is null. Are there any additional steps I need to hook up this complex object? Cheers Paul

    Read the article

  • Ado.net performance:What does SNIReadSync do?

    - by Beatles1692
    We have a query that takes 2 seconds to run in Sql Server Management Studio but it takes 13 seconds to be shown on a client screen. I used dotTrace to profile my source code and noticed there is this SNIReadSync method (part of ADO.net assemblies)that takes a lot of time to do its job(9 seconds).I ran my source over server so I could omit the network effects and the result was the same. It doesn't matter if I'm using OleDBConnection or SqlConnection. It doesn't matter if I'm using a DataReader or a DataSet. Connection pooling does not solve this issue(as my result shows). I googled this issue and I couldn't find an answer to the question that what this method is actually doing and how we can improve it. here's what I found on StakOverFlow that's not helpful either: http://stackoverflow.com/questions/1610874/snireadsync-executing-between-120-500-ms-for-a-simple-query-what-do-i-look-for

    Read the article

  • Coinitialize error on IntraWeb using ADO

    - by Jamo
    Already asked on the Evil Exchange, but as always that was no help. I'm having this problem today: When creating a stand alone web application using IntraWeb, I get this exception in the IDE when I try to test out a session from my app in the browser: First chance exception at $7C812A6B. Exception class EOleSysError with message 'CoInitialize has not been called'. Process WebContactManager.exe (1112) If I click "continue" on the IDE exception dialog, the browser itself just shows: 200 OK ...rather than the controls on my main form. This error does not seem to occur when I replace ADO with other database components such as dbExpress or BDE. What is this error telling me, and how do I fix it? (Note I'm using the stock "VCL for the Web" IntraWeb components which come built-in with D2007). Thanks in advance for any and all help!

    Read the article

  • JavaScript keeps returning ambigious error (in ASP.NET MVC 2.0)

    - by Erx_VB.NExT.Coder
    this is my function (with other lines ive tried/abandoned)... function DoClicked(eNumber) { //obj.style = 'bgcolor: maroon'; var eid = 'cat' + eNumber; //$get(obj).style.backgroundColor = 'maroon'; //var nObj = $get(obj); var nObj = document.getElementById(eid) //alert(nObj.getAttribute("style")); nObj.style.backgroundColor = 'Maroon'; alert(nObj.style.backgroundColor); //nObj.setAttribute("style", "backgroundcolor: Maroon"); }; This error keeps getting returned even after the last line in the function runs: Microsoft JScript runtime error: Sys.ArgumentUndefinedException: Value cannot be undefined. Parameter name: method this function is called with an "OnSuccess" set in my Ajax.ActionLink call (ASP.NET MVC)... anyone any ideas on this? i have these referenced... even when i remove the 'debug' versions for normal versions, i still get an error but the error just has much less information and says 'b' is undefined (probably a ms js library internal variable)... <script src="../../Scripts/MicrosoftAjax.debug.js" type="text/javascript"></script> <script src="../../Scripts/MicrosoftMvcValidation.debug.js" type="text/javascript"></script> <script src="../../Scripts/MicrosoftMvcAjax.debug.js" type="text/javascript"></script> <script src="../../Scripts/jquery-1.4.1.js" type="text/javascript"></script> also, this is how i am calling the actionlink method: Ajax.ActionLink(item.CategoryName, "SubCategoryList", "Home", New With {.CategoryID = item.CategoryID}, New AjaxOptions With {.UpdateTargetId = "SubCat", .HttpMethod = "Post", .OnSuccess = "DoClicked(" & item.CategoryID.ToString & ")"}, New With {.id = "cat" & item.CategoryID.ToString})

    Read the article

  • Serializing Complex ViewModel with Json.Net Destabilization Error on Latest Version

    - by dreadlocks1221
    I just added the latest Version of JSON.Net and I get the System.Security.VerificationException: Operation could destabilize the runtime error when trying to use a controller (while running the application). I read in other posts that this issue should have been fixed in release 6 but I still have the problem. I even added *Newtonsoft.* to the ignore modules in the intellitrace options, which seems to have suppressed the error, but the post will just run forever and not return anything. Any help I can get would be greatly appreciated. [HttpPost] public string GetComments(int ShowID, int Page) { int PageSize = 10; UserRepository UserRepo = new UserRepository(); ShowCommentViewModel viewModel = new ShowCommentViewModel(); IQueryable<Comment> CommentQuery = showRepository.GetShowComments(ShowID); var paginatedComments = new PaginatedList<Comment>(CommentQuery, Page, PageSize); viewModel.Comments = new List<CommentViewModel>(); foreach (Comment comment in CommentQuery.Take(10).ToList()) { CommentViewModel CommentModel = new CommentViewModel { Comment = comment, PostedBy = UserRepo.GetUserProfile(comment.UserID) }; IQueryable<Comment> ReplyQuery = showRepository.GetShowCommentReplies(comment.CommentID); int ReplyPage = 0; var paginatedReplies = new PaginatedList<Comment>(ReplyQuery, ReplyPage, 3); CommentModel.Replies = new List<ReplyModel>(); foreach (Comment reply in ReplyQuery.Take(3).ToList()) { ReplyModel rModel = new ReplyModel { Reply = reply, PostedBy = UserRepo.GetUserProfile(reply.UserID) }; CommentModel.Replies.Add(rModel); } CommentModel.RepliesNextPage = paginatedReplies.HasNextPage; CommentModel.RepliesPeviousPage = paginatedReplies.HasPreviousPage; CommentModel.RepliesTotalPages = paginatedReplies.TotalPages; CommentModel.RepliesPageIndex = paginatedReplies.PageIndex; CommentModel.RepliesTotalCount = paginatedReplies.TotalCount; viewModel.Comments.Add(CommentModel); } viewModel.CommentsNextPage = paginatedComments.HasNextPage; viewModel.CommentsPeviousPage = paginatedComments.HasPreviousPage; viewModel.CommentsTotalPages = paginatedComments.TotalPages; viewModel.CommentsPageIndex = paginatedComments.PageIndex; viewModel.CommentsTotalCount = paginatedComments.TotalCount; return JsonConvert.SerializeObject(viewModel, Formatting.Indented); }

    Read the article

  • Read XML file from ADO (VB6) Into .Net DataSet

    - by Jimbo
    I am trying to assist users in migrating from a VB6 application to a C# application. The VB6 app allows the export of data from an ADO (2.8) recordset via XML, but the C# application fails to read the XML producing the following error: System.Data.DuplicateNameException: A column named 'name' already belongs to this DataTable VB6 Code Dim RS As Recordset Set RS = p_CN.Execute("SELECT * FROM tblSuppliers INNER JOIN tblSupplierGroups ON tblSupplierGroups.SupplierGroupID=tblSuppliers.SupplierGroupID") RS.Save sDestinationFile, adPersistXML Set RS = Nothing C# Code DataSet ds = new DataSet(); ds.ReadXml(xmlFilePath); I have obviously incorrectly assumed that the XML file format was universally understood?

    Read the article

  • [Asp.Net MVC] Encoding a character

    - by Trimack
    Hi, I am experiencing some weird encoding behaviour in my ASP.NET MVC project. In my Site.Master there is <div class="logo"> <a href="<%=Url.Action("Index", "Win7")%>"><%= Html.Encode("Windows 7 Tutoriál") %></a></div> which translates to the resulting page as <div class="logo"> <a href="/">Windows 7 TutoriA?l</a></div> However, in the Index.aspx there is <h1> Windows 7 Tutoriál</h1> which translates correctly on the same resulting page. I do have <meta http-equiv="Content-Type" content="text/html; charset=utf-8" /> as my first line in <head>. Locally, both files are saved in UTF-8 encoding. Any ideas why is this happening and how to fix it? Thanks in advance.

    Read the article

  • ADO.NET Entity Model and LINQ

    - by Richard
    Hi all I'm using an ADO.NET Entity Model which I'm trying to query using LINQ. The problem I'm having is that I can't specify the where clause as I'd like. For instance, consider the following query: AccountsDM db = new AccountsDM(ConfigurationManager.ConnectionStrings["PrimaryEF"].ConnectionString); var accounts = from a in db.Accounts select a; foreach (var account in accounts) { foreach (var ident in account.Identifiers) { if (ident.Identifier == identifier) { // ident.Identifier is what I'd like to be filtering in the WHERE clause below } } } Ideally, I'd like that to become: var accounts = from a in db.Accounts where a.Identifiers.Identifier == identifier select a; I'm guessing I've probably not set up my Entity Model correctly in VS2010. Any advice you can offer would be gratefully received. Thanks, Richard.

    Read the article

  • ADO.NET Commands and SQL query plans

    - by ingredient_15939
    I've been reading up on query plans and how to minimise duplicate plans being created by SQL Server for the same basic query. For example, if I understand correctly, sending both these query strings will result in 2 different query plans: "SELECT FirstName FROM Members WHERE LastName = 'Lee'" "SELECT FirstName FROM Members WHERE LastName = 'MacGhilleseatheanaich'" Using a stored procedure avoids this, as the query plan is the same, and "LastName" is passed as a variable, eg: CREATE PROCEDURE sp_myStoredProcedure @LastName varchar(100) AS SELECT FirstName FROM Members WHERE LastName = @LastName Go Now, my question is whether the same applies to the Command object (eg. SQLClient.SQLCommand in ADO.NET). The reason I ask is that string parameters don't have a defined max length, as in the code above. Take the following code: MyCmd.CommandText = "SELECT FirstName FROM Members WHERE LastName = @LastName" MyCmd.Parameters.AddWithValue("@LastName", "Lee") Then later: MyCmd.Parameters.Clear() MyCmd.Parameters.AddWithValue("@LastName", "MacGhilleseatheanaich") Since @LastName hasn't been declared to SQL Server as having a defined maximum length, will SQL Server create a new query plan for every different value when I execute the command this way?

    Read the article

  • asp.net mvc making delete usercontrol information passing on and off

    - by mazhar kaunain baig
    i am creating a generalize deleteusercontrol , my aim is that on the listing page where all the records are listed when the delete is pressed i want to display the acknowledgment on the same page up the list. I had little idea to do that q1) first of all where will i place my deleteusercontrol(in the shared folder?). q2) on and off the deleteusercontrol as the acknowledgment will not be there all the time how would i be doing that on delete press. i don't want to pass any data in the querystring. q3)how would i be passing the records list id and listname to the general deleteusercontrol as it would be same for all the listing

    Read the article

  • Converting DAO to ADO

    - by webworm
    I am working with an Access 2003 database that has a subroutine using DAO code. This code loops through the table definitions and refreshes the ODBC connection string. I would like to convert this to ADO so I do not have to reference the DAO object library. Here is the code ... Public Sub RefreshODBCLinks(newConnectionString As String) Dim db As DAO.Database Dim tb As DAO.TableDef Set db = CurrentDb For Each tb In db.TableDefs If Left(tb.Connect, 4) = "ODBC" Then tb.Connect = newConnectionString tb.RefreshLink Debug.Print "Refreshed ODBC table " & tb.Name End If Next tb Set db = Nothing MsgBox "New connection string is " & newConnectionString, vbOKOnly, "ODBC Links refreshed" End Sub The part I am unsure of is how to loop through the tables and get/set their connection strings.

    Read the article

  • Implementing a normal website inside ASP.NET MVC 2

    - by cc0
    I have a website consisting of an index.html, a number of style sheet files as well as some javascript files. Then I needed a way for this site to communicate efficiently with a Microsoft SQL Server, so I was recommended to use the MVC framework to facilitate that kind of communication. I created the C#.net controller code needed to output the necessary information from the database using URL parameters, so now I am trying to put the whole web-site together inside the MVC framework. I started an empty project-template in MVC 2 framework. I'm sure there must be a good way to implement the current code into this framework, but I am very uncertain as to what the best approach to this would be. Could anyone point me in the right direction here? I'm not sure whether I need to change any of the current HTML, or exactly what to add to it. I'd love to see some kind of guide or tutorial, or just any advice I can get as I try to learn this. Any help is very much appreciated!

    Read the article

  • Obtain stored procedure metadata for a procedure within an Oracle package using ADO.NET

    - by alwayslearning
    Hi, I am trying to obtain the stored procedure metadata (procedure name,parameter types,parameter names etc) for a procedure declared within an Oracle package, using the standard ADO.NET API - DbConnection.GetSchema call. I am using the ODP driver. I see that the Package is listed in the 'Packages' and 'PackageBodies' metadata collections. The procedure parameter appears in the 'Arguments' and 'ProcedureParameters' collections. I do not see a way to get to the procedure information via the package metadata. Even if the procedure does not have any parameters there is a row in the 'ProcedureParameters' collection for this procedure. My question: To obtain the procedure metadata do I have to query the 'ProcedureParameters' collection and search for an entry with the required package name? I can then construct the procedure metadata based on the parameter information. Is there a shorter or quicker way to obtain the same information?

    Read the article

  • ADO "Unspecified Error" instead of actual error when fetching server side cursor

    - by Dan
    This relates to my recent question: http://stackoverflow.com/questions/2835663/force-oracle-error-on-fetch I am now able to reproduce a scenario where using ADO with the Oracle OLEDB Provider, I can force an error such as ORA-01722: invalid number to occur on calling Recordset.MoveNext However, this is not the error that is returned to the application. Instead, the application sees Provider error '80004005' Unspecified error. How can I get the application to see the real error from the database? This is with Oracle 10g (client and server), if it matters. Sample code is roughly as follows: Dim con As New ADODB.Connection Dim cmd As New ADODB.Command Dim rs As ADODB.Recordset con.ConnectionString = "Provider=OraOLEDB.ORACLE;Data Source=xxx;User Id=yyy;Password=zzz" con.CursorLocation = adUseServer con.Open Set cmd.ActiveConnection = con cmd.CommandText = "select * from table(ret_err)" cmd.Prepared = True Set rs = cmd.Execute While Not rs.EOF rs.MoveNext Wend

    Read the article

  • Return database messages on successful SQL execution when using ADO

    - by peacedog
    I'm working on a legacy VB6 app here at work, and it has been a long time since I've looked at VB6 or ADO. One thing the app does is to executes SQL Tasks and then to output the success/failure into an XML file. If there is an error it inserts the text the task node. What I have been asked to do is try and do the same with the other mundane messages that result from succesfully executed tasks, like (323 row(s) affected). There is no command object being used, it's just an ADODB.Connection object. Here is the gist of the code: Dim sqlStatement As String Set sqlStatement = /* sql for task */ Dim sqlConn As ADODB.Connection Set sqlConn = /* connection magic */ sqlConn.Execute sqlStatement, , adExecuteNoRecords What is the best way for me to capture the non-error messages so I can output them? Or is it even possible?

    Read the article

  • How to retrieve all errors and messages from a query using ADO

    - by Johan Levin
    When a SQL batch returns more than one message from e.g. print statements, then I can only retrieve the first one using the ADO connection's Errors collection. How do I get the rest of the messages? If I run this script: Option Explicit Dim conn Set conn = CreateObject("ADODB.Connection") conn.Provider = "SQLOLEDB" conn.ConnectionString = "Data Source=(local);Integrated Security=SSPI;Initial Catalog=Master" conn.Open conn.Execute("print 'Foo'" & vbCrLf & "print 'Bar'" & vbCrLf & "raiserror ('xyz', 10, 127)") Dim error For Each error in conn.Errors MsgBox error.Description Next Then I only get "Foo" back, never "Bar" or "xyz". Is there a way to get the remaining messages?

    Read the article

  • Join with ADO.NET Linq to Entity in C#

    - by aladdin
    Hello I'm try to migrate a system to ADO.NET Entity I have 3 table A => (Id, Name, ...) B => (Id, Domain, ...) c => (IdA, IdB) VS.NET generate 2 entity A and B and both have reference to the other table but this reference is a collection. I need make a join between tables. from a in A join b in B on a.? equal b.? where condition select new { Name = a.Name, Domain = b.Domain }; I cant do that follow the reference in entity bu when the problem grows can be a problem. Any Help?

    Read the article

  • ASP.Net navigation tabs like windows tab control

    - by devphil
    I would like to have a webpage something like windows tab control. Each webpage does not lose the contents and data while moving between pages, postbacks, etc. Here is the website design and my idea: [Master Page] "Fruits" "Cars" "Animals" "Operators" clicking on "Fruits" will forwards to "Fruits" page, and the same for other links (tabs) The user works on "Fruits" page searching fruits, fill up some fields, etc. The user then moves to "Cars" page and then builds up his own car by filling some fields, etc and then the user goes back to "Fruits" page again - the user sees the same page where she/he left on "Fruits" page. Please suggest some good ways other than using javascript:history.go(-1). Is this possible to implement?

    Read the article

  • ADO.NET DataService Exception

    - by Ravi
    Hi, I am working on C#.Net with ADO.NET Dataservice. I try to update one record to relational tabel, when I reach context.SetLink() I am getting exception("The context is not currently tracking the entity"). I don't know how to solve this problem. My code is specified below. LogNote dbLogNote =logNote; LogSubSession dbLogSubSession = (from p in context.LogSubSession where p.UID == logNote.SubSessionId select p).First<LogSubSession>() as LogSubSession; context.AddToLogNote(dbLogNote); dbLogNote.LogSubSession = dbLogSubSession; context.SetLink(dbLogNote, "LogSubSession", dbLogSubSession); context.SaveChanges(); Here LogSubSession is a primary table and LogNote is a foreign table. I am updating data into foreign table based on primary key table. Thanks

    Read the article

  • Crash when checking BOF property of pessimistic locked ADO recordset

    - by Patrick
    Bit of an odd one for you: I've got two connections to a database, on one I've opened a _RecordsetPtr with a pessimistic lock. I can no longer send an UPDATE command on the other connection. I can send a SELECT command on the second connection and data is returned. If I use a read only lock then there are no problems however when I use a pessimistic lock on the second connection as well I can check the State == adStateOpen but the program hangs when I test the BOF property! If I don't test the BOF property and try to call moveNext on the second connection the software hangs If I do neither of these I am able to access the data via the second connection but trying to access the data from the first connection causes the software to hang. Any one seen anything similar as I'm a bit stuck? EDIT : it wasn't hanging, someone had put a 30 minute timeout on the connection and I wasn't waiting that long while testing...

    Read the article

  • How to build a good service layer in ASP.NET?

    - by Swippen
    I have looked through some questions, technologies for building a good service layer but I have some questions regarding this that I need help with. First some information of what I have for requirements. We currently have a number of web applications that talk to each other in a spiderweb looking way (all talking to each other in a confusing way via webservices and database data). We want to change this so that all applications go through a service layer where we can work more with cache and encapsulate common functionality and more. We want this layer to also have a Web API so that 3rd party clients can consume information from the service. The problem I see is that if we build the service layer with say MVC4 Web API don't we need to communicate between the application using the webAPI meaning we have to construct URLs and consume JSON/Xml. That does not sound too effective. I assume a better method would be working with entities and WCF to communicate between the application but then we might loose the Web API magic? So the question is if there is a way to consume a service layer as both a Web API (JSON/XML) and as a more backend service layer with entities. If we are forced to use 2 different service layers we might have to duplicate some functionality and other bad things. Hope the question is clear enough and please ask if you need any more information.

    Read the article

  • ASP.NET MVC, Url Routing: Maximum Path (URL) Length

    - by Martin Aatmaa
    The Scenario I have an application where we took the good old query string URL structure: ?x=1&y=2&z=3&a=4&b=5&c=6 and changed it into a path structure: /x/1/y/2/z/3/a/4/b/5/c/6 We're using ASP.NET MVC and (naturally) ASP.NET routing. The Problem The problem is that our parameters are dynamic, and there is (theoretically) no limit to the amount of parameters that we need to accommodate for. This is all fine until we got hit by the following train: HTTP Error 400.0 - Bad Request ASP.NET detected invalid characters in the URL. IIS would throw this error when our URL got past a certain length. The Nitty Gritty Here's what we found out: This is not an IIS problem IIS does have a max path length limit, but the above error is not this. Learn dot iis dot net How to Use Request Filtering Section "Filter Based on Request Limits" If the path was too long for IIS, it would throw a 404.14, not a 400.0. Besides, the IIS max path (and query) length are configurable: <requestLimits maxAllowedContentLength="30000000" maxUrl="260" maxQueryString="25" /> This is an ASP.NET Problem After some poking around: IIS Forums Thread: ASP.NET 2.0 maximum URL length? http://forums.iis.net/t/1105360.aspx it turns out that this is an ASP.NET (well, .NET really) problem. The shit of the matter is that, as far as I can tell, ASP.NET cannot handle paths longer than 260 characters. The nail in the coffin in that this is confirmed by Phil the Haack himself: Stack Overflow ASP.NET url MAX_PATH limit Question ID 265251 The Question So what's the question? The question is, how big of a limitation is this? For my app, it's a deal killer. For most apps, it's probably a non-issue. What about disclosure? No where where ASP.NET Routing is mentioned have I ever heard a peep about this limitation. The fact that ASP.NET MVC uses ASP.NET routing makes the impact of this even bigger. What do you think?

    Read the article

  • Role of Microsoft certifications ADO.Net, ASP.Net, WPF, WCF and Career?

    - by Steve Johnson
    I am a Microsoft fan and .Net enthusiast. I want to align my career in the lines of current and future .Net technologies. I have an MCTS in ASP.Net 3.5. The question is about the continuation of certifications and my career growth and maybe a different job! I want to keep pace with future Microsoft .Net technologies. My current job however doesn't allow so.So i bid to do .Net based certifications to stay abreast with latest .Net technologies. My questions: What certifications should i follow next? I have MCTS .Net 3.5 WPF(Exam 70-502) and MCTS .Net 3.5 WCF(Exam 70-504) in my mind so that i can go for Silverlight development and seek jobs related to Silverlight development. What other steps i need to take in order to develop professional expertise in technologies such as WPF, WCF and Silverlight when my current employer is reluctant to shift to latest .Net technologies? I am sure that there are a lot of people of around here who are working with .Net technologies and they have industrial experience. I being a new comer and starter in my career need to take right decision and so i am seeking help from this community in guiding me to the right path. Expert replies are much appreciated and thanks in advance. Best Regards Steve.

    Read the article

  • SQL Developer Debugging, Watches, Smart Data, & Data

    - by thatjeffsmith
    After presenting the SQL Developer PL/SQL debugger for about an hour yesterday at KScope12 in San Antonio, my boss came up and asked, “Now, would you really want to know what the Smart Data panel does?” Apparently I had ‘made up’ my own story about what that panel’s intent is based on my experience with it. Not good Jeff, not good. It was a very small point of my presentation, but I probably should have read the docs. The Smart Data tab displays information about variables, using your Debugger: Smart Data preferences. You can also specify these preferences by right-clicking in the Smart Data window and selecting Preferences. Debugger Smart Data Preferences, control number of variables to display The Smart Data panel auto-inspects the last X accessed variables. So if you have a program with 26 variables, instead of showing you all 26, it will just show you the last two variables that were referenced in your program. If you were to click on the ‘Data’ debug panel, you’ll see EVERYTHING. And if you only want to see a very specific set of values, then you should use Watches. The Smart Data Panel As I step through the code, the variables being tracked change as they are referenced. Only the most recent ones display. This is controlled by the ‘Maximum Locations to Remember’ preference. Step through the code, see the latest variables accessed The Data Panel All variables are displayed. Might be information overload on large PL/SQL programs where you have many dozens or even hundreds of variables to track. Shows everything all the time Watches Watches are added manually and only show what you ask for. Data on Demand – add a watch to track a specific variable Remember, you can interact with your data If you want to do more than just watch, you can mouse-right on a data element, and change the value of the variable as the program is running. This is one of the primary benefits to debugging over using DBMS_OUTPUT to track what’s happening in your program. Change the values while the program is running to test your ‘What if?’ scenarios

    Read the article

< Previous Page | 45 46 47 48 49 50 51 52 53 54 55 56  | Next Page >