Search Results

Search found 18244 results on 730 pages for 'controller action'.

Page 559/730 | < Previous Page | 555 556 557 558 559 560 561 562 563 564 565 566  | Next Page >

  • 403 Forbidden when Deploying asp.net 4.0 site to IIS 7

    - by Jordan
    So I have an EC2 instance running, the URL NoWeatherSurprises.com I have the DNS pointing there, and I set up a new site in IIS 7 and pointed it to a folder. I used Visual Studios Web Developer 2010 express to publish to this folder. It now has the binaries and such. However if I go to NoWeatherSurprises.com I get the welcome to IIS 7 screen. I'd expect to go to my application If I navigate to http://noweathersurprises.com/weather/ [weather was the folder I published to under wwwroot] I get a 403 forbidden. I have no idea why, I am guessing that it is trying to do a directory listing or something instead of launching my MVC Application. So 2 problems in summary. It is not pointing the domain to the folder directly and I need to add /weather I am getting a 403 forbidden instead of the results of my home controller with the index action. I am new to IIS 7, I had been using IIS 6 and had a lot less trouble setting it up, but I suspect that's my own fault and i am just missing something. Thanks in advance for any help

    Read the article

  • Blender refuses to start

    - by Sekhemty
    I'm trying to run Blender under Linux, but I'm unable to do that, whenever I try I get some errors. I'm using Kubuntu 12.04 with KDE 4.11.1. This is my video card: ~$ lspci | grep VGA 01:00.0 VGA compatible controller: Advanced Micro Devices, Inc. [AMD/ATI] RV610/M74 [Mobility Radeon HD 2400 XT] I used to have installed the fglrx proprietary Catalyst drivers, but lately they gave me some system-wide problems and I had to revert to the open source Mesa drivers (I don't think that these details are important, but just in case, the whole story is here). Whit the fglrx drivers Blender was running fine, but now, whenever I try to start it, I get this error message (some parts are in italian, but I think that they are easily understandable): ~$ blender connect failed: No such file or directory Writing: /tmp/blender.crash.txt Errore di segmentazione (core dump creato) The content of /tmp/blender.crash.txt is as follows: # Blender 2.68 (sub 5), Revision: 60150 # backtrace /usr/lib/blender/blender() [0x877a41f] [0xb7756400] /usr/lib/i386-linux-gnu/libLLVM-3.0.so.1(_ZN4llvm3ARM8SPRClassC1Ev+0x15) [0xa8f4a9d5] /usr/lib/i386-linux-gnu/libLLVM-3.0.so.1(+0x25ca48) [0xa8eefa48] /lib/ld-linux.so.2(+0xeeab) [0xb7765eab] /lib/ld-linux.so.2(+0xef94) [0xb7765f94] /lib/ld-linux.so.2(+0x12fa6) [0xb7769fa6] /lib/ld-linux.so.2(+0xeccf) [0xb7765ccf] /lib/ld-linux.so.2(+0x127f4) [0xb77697f4] /lib/i386-linux-gnu/libdl.so.2(+0xbe9) [0xb4ff9be9] /lib/ld-linux.so.2(+0xeccf) [0xb7765ccf] /lib/i386-linux-gnu/libdl.so.2(+0x133a) [0xb4ffa33a] /lib/i386-linux-gnu/libdl.so.2(dlopen+0x47) [0xb4ff9c97] /usr/lib/i386-linux-gnu/mesa/libGL.so.1(+0x3cbf0) [0xb7717bf0] /usr/lib/i386-linux-gnu/mesa/libGL.so.1(+0x4079d) [0xb771b79d] /usr/lib/i386-linux-gnu/mesa/libGL.so.1(+0x1a3aa) [0xb76f53aa] /usr/lib/i386-linux-gnu/mesa/libGL.so.1(glXQueryVersion+0x2e) [0xb76f0cee] /usr/lib/blender/blender(_ZN15GHOST_WindowX11C1EP15GHOST_SystemX11P9_XDisplayRK10STR_Stringiijj18GHOST_TWindowStatei25GHOST_TDrawingContextTypebbt+0x11c) [0x8f54aec] /usr/lib/blender/blender(_ZN15GHOST_SystemX1112createWindowERK10STR_Stringiijj18GHOST_TWindowState25GHOST_TDrawingContextTypebbti+0xd7) [0x8f4f4a7] /usr/lib/blender/blender(GHOST_CreateWindow+0xb6) [0x8f4cf86] /usr/lib/blender/blender(wm_window_add_ghostwindows+0x205) [0x8799be5] /usr/lib/blender/blender(WM_check+0x50) [0x877b670] /usr/lib/blender/blender(wm_homefile_read+0x111) [0x87859f1] /usr/lib/blender/blender(WM_init+0xd2) [0x8787872] /usr/lib/blender/blender(main+0xe6e) [0x873848e] /lib/i386-linux-gnu/libc.so.6(__libc_start_main+0xf3) [0xb4e694d3] /usr/lib/blender/blender() [0x8778a99] The only thing that I can guess from this report is that the mesa drivers are somewhat involved, as I already suspected, but I don't have a clue on what I need to do to try to solve the issue.

    Read the article

  • How to transfer files via infrared on Linux?

    - by arielnmz
    I know this is a way too old technology but I've got some files inside a very old cellphone that I need to transfer to a very old computer. So far my Infrared USB device works well, it's detected by the machine (lsusb output): Bus 002 Device 002: ID 0df7:0620 Mobile Action Technology, Inc. MA-620 Infrared Adapter I've tried to send the file over MMS and even email (it lacks bluetooth, not to mention USB). But this cellphones's firmware doesn't let me attach the files. The file was originally transfered via IrDA, and it only has an internal memory (a whole 2 million bytes! whoa!). I found a package called irda-utils, but it seems that there are only two executables: irdaping and irdadump. I think the dump utility might do the job (which as far as I can see it's kind of a version of tcpdump but for IrDA), but I don't even know how to process the received frames. Could this question may be what I'm looking for? EDIT While reading through the Linux Infrared HOWTO I found about the OpenObex project, which may be what I'm looking for...

    Read the article

  • "The directory name is invalid" when trying to install drivers in Windows 7 via Device Manager

    - by Luke
    First off, this computer is not mine, it's a customer's system. Having said that... The hard drive was moved to a new motherboard, CPU, RAM combo, and booted up fine. Customer puts in driver CD, drivers won't load. He brings it into me. Under Device Manager for Windows 7 x64, I see lots of PCI to PCI bridge, one SMBus Controller, and about 20 Unknown Devices. Greeeeeat... So I start with the SMBus driver directly from the Asus website for the motherboard (P8H77-M Pro). If I install from the setup program, it tells me to reboot, then it starts the install. It gets half way through the setup, then fails (An unknown error occurred. Setup will exit). When I try to point to the folder from Device Manager, it starts copying files for the driver, even presents me with the proper name of the device, but says that an error has occurred there as well: The directory name is invalid. Doing some Googling, I saw that many people had this issue with Vista. K, Vista and 7 are similar, maybe the solutions are the same... But they aren't. I tried: Copying the entire driver folder and setup utility to the Program Files folder and running it / selecting it in DM Downloading another set of drivers in case this one is corrupt Disabling UAC Deleting and recreating the %WINDIR%\TEMP folder Removing all references to previous hardware that I could find, even in Device Manager's hidden mode So far, nothing has worked. A wipe and reload will be out of the question

    Read the article

  • New router messed up server 2003 setup...

    - by Aceth
    Hey, We were sent a new 2wire router today configured it as best we can to match the old bt voyager. We've also got X static IP's. We've manage to get our webserver on one of the new IP's public facing. then we use a hardware firewall which is in a DMZ again with a different static IP. This firewall then is our gateway for our internal LAN. with a few servers etc. The problem we're having is only our PDC (primary Domain controller which has exchange 2003 on) can't ping externally even an external IP. We've connected laptops to the 2wire router and obtain a private ip 192.168.1.X and it works fine can ping etc. our other servers with an internal ip behind the firewall can ping out fine. We've connected to the firewalls logging console and the pings from the server are allowed through so its fine there. The server in question is a Windows server 2003 R2 Enterprise SP2 + Exchange 2003 Server doesn't have firewall turned on. it has static private IP .. gateway is pointing to the right one External Static IP is routing fine inwards We've ran out of ideas .. help??

    Read the article

  • "Open file location" is broken for Win Live Photo Gallery and Chrome

    - by Arnold Spence
    Symptoms: Windows Live Photo Gallery: Right clicking on an image (.jpg, .png) and selecting the context menu item "Open file location" should open the containing folder in explorer. Instead, I get an error dialog stating "This file does not have a program associated with it for performing this action. Please install a program or, if one is already installed, create an association in the Default Programs control panel." Chrome: After downloading a file (of any type), clicking the down arrow on the download status bar at the bottom and clicking "Show in folder" results in the same error dialog mentioned above. I'm using Windows 7. I'm pretty sure this is a registry entry gone bad but I've been unable to locate any information about this specific problem. It's not a file type association problem as I am not trying to open the files concerned, I'm trying to open an explorer window at the location for the file. I've found a similar issue that somebody had with explorer itself. However, the suggested registry fixes here for "Folder", "Directory" and "Drive" did not solve the problem. Also, If I use the searchbar in explorer to do a search, right click on a file and choose "Open file location", explorer jumps to that location without any trouble. I have not yet identified other programs with this issue.

    Read the article

  • Password Policy seems to be ignored for new Domain on Windows Server 2008 R2

    - by Earl Sven
    I have set up a new Windows Server 2008 R2 domain controller, and have attempted to configure the Default Domain Policy to permit all types of passwords. When I want to create a new user (just a normal user) in the Domain Users and Computers application, I am prevented from doing so because of password complexity/length reasons. The password policy options configured in the Default Domain Policy are not defined in the Default Domain Controllers Policy, but having run the Group Policy Modelling Wizard these settings do not appear to be set for the Domain Controllers OU, should they not be inherited from the Default Domain policy? Additionally, if I link the Default Domain policy to the Domain Controllers OU, the Group Policy Modelling Wizard indicates the expected values for complexity etc, but I still cannot create a new user with my desired password. The domain is running at the Windows Server 2008 R2 functional level. Any thoughts? Thanks! Update: Here is the "Account policy/Password policy" Section from the GPM Wizard: Policy Value Winning GPO Enforce password history 0 Passwords Remembered Default Domain Policy Maximum password age 0 days Default Domain Policy Minimum password age 0 days Default Domain Policy Minimum password length 0 characters Default Domain Policy Passwords must meet complexity Disabled Default Domain Policy These results were taken from running the GPM Wizard at the Domain Controllers OU. I have typed them out by hand as the system I am working on is standalone, this is why the table is not exactly the wording from the Wizard. Are there any other policies that could override the above? Thanks!

    Read the article

  • Something very strange with network

    - by Rodnower
    Hello, I have Windows 7 and I have very strange thing with my network. Some time I was connected through wireless router and my IP was 192.168.2.103, router's IP was 192.168.2.1 and some other IP was 192.168.2.100. The last I get from page "active DHCP clients" of web interface of the router and from "wireless clients" I may to see that 192.168.2.100 not (!) belong to my MAC address. Router build by EDimax. So after that I disabled wireless function of the router and restarted it. In this time I had not ping to 192.168.2.1. Also I had not any other connection, not wireless nor cable, but (!) I still had ping to 192.168.2.100 and I not understand what this voodoo is... C:\Users\Andrey>ping 192.168.2.100 Pinging 192.168.2.100 with 32 bytes of data: Reply from 192.168.2.100: bytes=32 time<1ms TTL=128 Reply from 192.168.2.100: bytes=32 time<1ms TTL=128 Reply from 192.168.2.100: bytes=32 time<1ms TTL=128 Reply from 192.168.2.100: bytes=32 time<1ms TTL=128 Ping statistics for 192.168.2.100: Packets: Sent = 4, Received = 4, Lost = 0 (0% loss), Approximate round trip times in milli-seconds: Minimum = 0ms, Maximum = 0ms, Average = 0ms This is what I had: C:\Users\Andrey>ipconfig /all Windows IP Configuration Host Name . . . . . . . . . . . . : Andrey-PC Primary Dns Suffix . . . . . . . : Node Type . . . . . . . . . . . . : Hybrid IP Routing Enabled. . . . . . . . : No WINS Proxy Enabled. . . . . . . . : No Wireless LAN adapter Wireless Network Connection 3: Media State . . . . . . . . . . . : Media disconnected Connection-specific DNS Suffix . : Description . . . . . . . . . . . : Microsoft Virtual WiFi Miniport Adapter #2 Physical Address. . . . . . . . . : 06-1D-7D-40-61-EB DHCP Enabled. . . . . . . . . . . : Yes Autoconfiguration Enabled . . . . : Yes Wireless LAN adapter Wireless Network Connection: Media State . . . . . . . . . . . : Media disconnected Connection-specific DNS Suffix . : Description . . . . . . . . . . . : Gigabyte GN-WS50G (mini) PCI-E WLAN Card Physical Address. . . . . . . . . : 00-1D-7D-40-61-EB DHCP Enabled. . . . . . . . . . . : Yes Autoconfiguration Enabled . . . . : Yes Ethernet adapter Local Area Connection: Media State . . . . . . . . . . . : Media disconnected Connection-specific DNS Suffix . : Description . . . . . . . . . . . : Marvell Yukon 88E8055 PCI-E Gigabit Ethernet Controller Physical Address. . . . . . . . . : 00-1B-24-B6-09-91 DHCP Enabled. . . . . . . . . . . : Yes Autoconfiguration Enabled . . . . : Yes C:\Users\Andrey>arp -a -v Interface: 127.0.0.1 --- 0x1 Internet Address Physical Address Type 224.0.0.22 static 239.255.255.250 static Interface: 0.0.0.0 --- 0xffffffff Internet Address Physical Address Type 192.168.2.1 00-0e-2e-d2-8c-af invalid 192.168.2.255 ff-ff-ff-ff-ff-ff static 224.0.0.22 01-00-5e-00-00-16 static 224.0.0.252 01-00-5e-00-00-fc static 239.255.255.250 01-00-5e-7f-ff-fa static 255.255.255.255 ff-ff-ff-ff-ff-ff static Interface: 0.0.0.0 --- 0xffffffff Internet Address Physical Address Type 192.168.2.1 00-0e-2e-ff-f1-f6 dynamic 192.168.2.101 00-27-19-bc-8b-9c dynamic 192.168.2.102 00-16-e6-6c-ae-d4 dynamic 192.168.2.255 ff-ff-ff-ff-ff-ff static 224.0.0.22 01-00-5e-00-00-16 static 224.0.0.252 01-00-5e-00-00-fc static 239.255.255.250 01-00-5e-7f-ff-fa static 255.255.255.255 ff-ff-ff-ff-ff-ff static Interface: 0.0.0.0 --- 0xffffffff Internet Address Physical Address Type 224.0.0.22 01-00-5e-00-00-16 static 255.255.255.255 ff-ff-ff-ff-ff-ff static C:\Users\Andrey>route print =========================================================================== Interface List 14...06 1d 7d 40 61 eb ......Microsoft Virtual WiFi Miniport Adapter #2 13...00 1d 7d 40 61 eb ......Gigabyte GN-WS50G (mini) PCI-E WLAN Card 11...00 1b 24 b6 09 91 ......Marvell Yukon 88E8055 PCI-E Gigabit Ethernet Controller 1...........................Software Loopback Interface 1 =========================================================================== IPv4 Route Table =========================================================================== Active Routes: Network Destination Netmask Gateway Interface Metric 127.0.0.0 255.0.0.0 On-link 127.0.0.1 306 127.0.0.1 255.255.255.255 On-link 127.0.0.1 306 127.255.255.255 255.255.255.255 On-link 127.0.0.1 306 224.0.0.0 240.0.0.0 On-link 127.0.0.1 306 255.255.255.255 255.255.255.255 On-link 127.0.0.1 306 =========================================================================== Persistent Routes: None IPv6 Route Table =========================================================================== Active Routes: If Metric Network Destination Gateway 1 306 ::1/128 On-link 1 306 ff00::/8 On-link =========================================================================== Persistent Routes: None Only after reboot I lost ping to there: C:\Users\Andrey>ping 192.168.2.100 Pinging 192.168.2.100 with 32 bytes of data: PING: transmit failed. General failure. PING: transmit failed. General failure. PING: transmit failed. General failure. PING: transmit failed. General failure. Ping statistics for 192.168.2.100: Packets: Sent = 4, Received = 0, Lost = 4 (100% loss), So what this mysterious cache is? Thank you for ahead.

    Read the article

  • Windows Server 2003 SBS domain in multiple sites

    - by E3 Group
    We have about 25 employees in our current office and are looking to open up another office in another capital city housing about 15 employees. In our current office, we are running a domain hosted by a 2003 SBS server and I've been tasked by the boss to expand our infrastructure to the new office in the cheapest way possible (cheapest way in the short run that is, because my boss doesn't think more than 6 months ahead). So I'm looking to get a second hand server and have it run Server 2003 Std with exchange server 2003. These are the things that it needs to do: Replicate shared folders that are hosted in the parent LAN. Deliver emails hosted in the parent Exchange Server Somehow link up with the parent domain controller and push the AD to the remote site I'm pretty sure 3 is impossible but the DC would be available if a VPN connection is present, right? On that note, would I be looking at hardware VPN connections? I'm not sure how to deploy the new site as this is my first time doing it and i'm making it especially difficult for myself, seeing as the AD and DC is on an SBS server. Would I first start by establishing a VPN connection and then joining the new server to the domain? Will things 'just work' if I install exchange onto the new server and point outlooks to it? and how would I be able to replicate shared folders?

    Read the article

  • How to use Python to read the physical address(MAC ID) [closed]

    - by getjoefree
    I want to read the physical address of the NIC model, i can get the results that i want to with SED.EXE before, but SED.EXE does not support my environment but Python ok, who have the means to do it. The general situation (not plug the network cable, it is impossible to obtain IP address): Ethernet adapter: Connection-specific DNS Suffix.: Chianet Description ...........: Marvell Yukon 88E8040 PCI-E Fast Ethernet Controller Physical Address .........: A4-BA-DB-9D-1E-8E Dhcp Enabled ...........: Yes Autoconfiguration Enabled ....: Yes Ethernet adapter 3: Media State . . . . . . . . . . . : Media disconnected Description . . . . . . . . . . . : Dell Wireless 1510 Wireless-N WLAN Mini-Card Physical Address. . . . . . . . . : 00-23-4D-D9-C0-28 The description of the NIC different, we can use this to fetch the corresponding physical address, base on Physical Address does not work, because the computer with the WLAN Card, I want to use Python to read my computer the card information and after Python handles an output file, output file format: SET MAC = A4BADB9D1E8E and sed format: ipconfig -all|sed -nrf getmac.sed | sed -e "s/-//g" > WINMAC.BAT getmac.sed: /Marvell Yukon 88E8040/ { n; s/.*: ([-0-9A-F]+)/set winmac=\1/p; }

    Read the article

  • Windows XP mounting USB drive to same letter as previously mapped network drive

    - by GAThrawn
    Why does Windows always mount a USB drive as the next drive letter after the last physical drive, even when that letter is already taken by a mapped drive, and is there any way to improve this behaviour? What happens is I tend to use a few different flash drives on my PC, as well as having both a Blackberry and a personal phone that mount as USB drives when I plug them in to charge. Being on a corporate PC I also have a number of mapped network drives (some set by login script, some set as persistent mappings in my profile). When I first login I'll have drive letters like this: C: - Local Drive D: - DVD Drive G: - Login script mapped drive J: - Login script mapped drive When I plug the Blackberry in it'll mount two drives (one for onboard storage, one for the SD card) as E: and F:. If I then plug in another USB drive it will mount as G:, even though that's already taken by a network mapped drive. This leaves me with the following drives: C: - Local Drive D: - DVD Drive E: - USB drive (Blackberry) F: - USB drive (Blackberry) G: - Login script mapped drive [G: - USB drive - mounted but not visible in Explorer or command prompt] J: - Login script mapped drive I then have to go into Disk Management, find the new USB drive that's mounted to G: and re-assign it to another letter eg Z:, once this is done Auto-Play detects it and throws up its normal dialog, and its browseable in Explorer. While this is OK to do if you only use one or two USB drives and have admin access to your PC with your login account, its a total pain in the proverbial if you regularly use a whole load of different USB devices, and corporate policy means you have one account for your normal login (that only has User access to workstations), but have to use a different account for any privileged action. I realize that one possible reason for this is the difference between hardware which is mounted and assigned drive letters at the systen level, and mapped drives which are done at the user level. For USB devices that are already plugged in before login, then obviously they're mounted before Windows knows what network drives may be mapped. However if you plug the USB devices in after you're fully logged in and have drives mapped then Windows must know which letters are available?

    Read the article

  • Re-configure Office 2007 installation unattended: Advertised components --> Local

    - by abstrask
    On our Citrix farm, I just found out that some sub-components are "Installed on 1st Use" (Advertised), which does play well on terminal servers. Not only that, but you also get a rather non-descriptive error message, when a document tried to use a component, which is "Installed on 1st Use" (described on Plan to deploy Office 2010 in a Remote Desktop Services environment): Microsoft Office cannot run this add-in. An error occurred and this feature is no longer functioning correctly. Please contact your system administrator. I have ~50 Citrix servers where I need to change the installation state of all Advertised components to Local, so I created an XML file like this: <?xml version="1.0" encoding="utf-8"?> <Configuration Product="ProPlus"> <Display Level="none" CompletionNotice="no" SuppressModal="yes" AcceptEula="yes" /> <Logging Type="standard" Path="C:\InstallLogs" Template="MS Office 2007 Install on 1st Use(*).log" /> <Option Id="AccessWizards" State="Local" /> <Option Id="DeveloperWizards" State="Local" /> <Setting Id="Reboot" Value="NEVER" /> </Configuration> I run it with a command like this (using the appropriate paths): "[..]\setup.exe" /config ProPlus /config "[..]\Install1stUse-to-Forced.xml" According to the log file, the syntax appears to be accepted and the config file parsed: Parsing command line. Config XML file specified: [..]\Install1stUse-to-Forced.xml Modify requested for product: PROPLUS Parsing config.xml at: [..]\Install1stUse-to-Forced.xml Preferred product specified in config.xml to be: PROPLUS But the "Final Option Tree" still reads: Final Option Tree: AlwaysInstalled:local Gimme_OnDemandData:local ProductFiles:local VSCommonPIAHidden:local dummy_MSCOMCTL_PIA:local dummy_Office_PIA:local ACCESSFiles:local ... AccessWizards:advertised DeveloperWizards:advertised ... And the components remain "Advertised". Just to see if the installation state is overridden in another XML file, I ran: findstr /l /s /i "AccessWizards" *.xml Against both my installation source and "%ProgramFiles%\Common Files\Microsoft Shared\OFFICE12\Office Setup Controller", but just found DefaultState to be "Local". What am I doing wrong? Thanks!

    Read the article

  • Laptop will not boot

    - by WillumMaguire
    This is a dell studio 1558 laptop. Now, something is wrong with the charger that it won't charge the laptop, but the laptop can turn on and operate properly as long as it is attached. It has been like this for a while, but it's not the problem. My problem is that as of yesterday, It takes several minutes to get past the "dell" startup logo (where is says "f2 setup" and "f12 boot options"). After it gets past, it beeps as normal to tell me about the charger and gives me the f2/f12 options and f1 to continue as normal. I can press f12 to get into boot options and load into my live USB BackTrack 5 ISO, but after "startx" it just stays at a black screen. I can also access BIOS setup, but see nothing that would help the problem. When I boot to the HDD, it gives me this Intel UNDI, PXE-2.1 (build 083) Realktek PCIe GBE Family Controller Series V.2.29 (06/30/09) PXE-E61: Media test failure, check cable PXE-M0F: Exiting PXE ROM Operating System not found Also, pressing f8 gives me the same results as booting as normal. It is running Windows 7 Ultimate, dual-core Intel i3 @ 2.27ghz and 4gb RAM. I think there is an issue with the HDD, as the "Operating System not found" would lead me to believe. Is this a fixable problem?

    Read the article

  • Raid-5 Performance per spindle scaling

    - by Bill N.
    So I am stuck in a corner, I have a storage project that is limited to 24 spindles, and requires heavy random Write (the corresponding read side is purely sequential). Needs every bit of space on my Drives, ~13TB total in a n-1 raid-5, and has to go fast, over 2GB/s sort of fast. The obvious answer is to use a Stripe/Concat (Raid-0/1), or better yet a raid-10 in place of the raid-5, but that is disallowed for reasons beyond my control. So I am here asking for help in getting a sub optimal configuration to be as good as it can be. The array built on direct attached SAS-2 10K rpm drives, backed by a ARECA 18xx series controller with 4GB of cache. 64k array stripes and an 4K stripe aligned XFS File system, with 24 Allocation groups (to avoid some of the penalty for being raid 5). The heart of my question is this: In the same setup with 6 spindles/AG's I see a near disk limited performance on the write, ~100MB/s per spindle, at 12 spindles I see that drop to ~80MB/s and at 24 ~60MB/s. I would expect that with a distributed parity and matched AG's, the performance should scale with the # of spindles, or be worse at small spindle counts, but this array is doing the opposite. What am I missing ? Should Raid-5 performance scale with # of spindles ? Many thanks for your answers and any ideas, input, or guidance. --Bill Edit: Improving RAID performance The other relevant thread I was able to find, discusses some of the same issues in the answers, though it still leaves me with out an answer on the performance scaling.

    Read the article

  • Can't install SB750 RAID drivers in Windows 7 for two additional storage drives

    - by jf46
    Mobo: ASUS M4A79XTD, 790X/SB750 OS: Windows 7 x64 I currently have SATA 1-4 set to RAID and SATA 5-6 set to IDE. I have an SSD connected to SATA5 with Windows 7 installed on it, and that works fine. I also have configured a RAID 1 array of two 1TB HDDs, connected to SATA 1 and 2. These don't show up in Windows, and I'm having trouble getting the RAID driver installed. I even tried booting from the Windows DVD and repairing or installing Windows, but when I navigated to the relevant .sys files on my motherboard's driver CD, Windows setup told me that the files in question weren't relevant to my hardware. To be clear: I'm not trying to install Windows on a RAID. I have Windows installed on a separate disk on a separate SATA controller. I just want to get the SB750 RAID drivers installed so that the Windows disk utility can see my RAID 1 array, which is composed of two other disks. Do I need to wipe my SSD and reinstall Windows to get the RAID driver installed? That seems kind of ridiculous, and given what I described above, I'm not even sure it would work. Any help or guidance would be appreciated - thanks! Edit: Also, I've copied the driver files from the mobo CD into system32 and rebooted, no luck. Then I changed HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services\iaStorV\Start from 3 to 0, and that didn't work either.

    Read the article

  • Are SATA II and SATA 3.0 Gbps compatible?

    - by Johnny Maelstrom
    I am trying to check that if I buy a new internal HDD it will work in the NAS I am buying. Currently I'm confused about naming schemes and once that is resolved whether there is compatibility. I will gladly author this question to be more general if there is not already an article helping with the confusion of SATA naming and standards. I see similar, but not identical questions and will accept this as a duplicate if thought as such. The specifications on the eCommerce site for the NAS says, "Controller Interface Type Serial ATA-150", the product home page for the manufacturer says, "Compatible with SATA and SATA II HDD". The specifications on the eCommerce site for the hard drives say, "Interface Type Serial ATA-300", the product home page for the manufacturer says, "Interface SATA 3.0 Gbps" Wikipedia says many things about different naming conventions, the closest being, "SATA II 3.0 Gbit/s, which was colloquially referred to as "SATA 3G" [bps] or "SATA 300" [MB/s] since 1.5 Gbit/s SATA I and 1.5 Gbit/s SATA II were referred to as both "SATA 1.5G" [b/s] or "SATA 150" [MB/s]). Therefore, they will operate with negligible differences between them." Are SATA II and SATA 3.0 Gbps the same? I feel I'm tantalisingly close to getting a definitive answer here before I purchase, but really want to clear up these naming schemes.

    Read the article

  • Very poor SCSI hd performance on IBM x336 with LSI 1030 RAID1

    - by David Tschoepe
    I'm experiencing very poor performance on an IBM x336 server with dual 73GB 15k hard drives on a U320 controller, LSI 1030. We're getting maybe 3.5MB/sec max (per HD Tune utility). It should be over 100MB/sec at least, I would think (another x335 box is running 70-80MB/sec). The server was recently setup and didn't really notice the problem, but may have been there from the beginning, so not sure. I have installed the IBM ServerRAID Windows utility. The server is running Windows 2008 R2 Web edition (if that matters). I thought maybe one of the drives was bad, so far I have removed one of the drives out of the array and tested again, but still the same results. I'm waiting for the RAID1 to resync and I will try pulling the other drive next. I've also used the ServerRAID utility but haven't noticed anything in there that might indicate a problem. Not sure if I'm on the right path here. So looking for some advice to track this down.

    Read the article

  • Fatal Execution Engine Error on the Windows2008 r2, IIS7.5

    - by user66524
    Hi Guys We are running some asp.net(3.5) applications on the Windows2008 r2, IIS7.5. Recently we got some event logs so difficult, we have not idea hope some guys can help. 1.EventID: 1334 (9-1-2011 8:41:57) Error message An error occurred during a process host idle check. Exception: System.AccessViolationException Message: Attempted to read or write protected memory. This is often an indication that other memory is corrupt. StackTrace: at System.Collections.Hashtable.GetEnumerator() at System.Web.Hosting.ApplicationManager.IsIdle() at System.Web.Hosting.ProcessHost.IsIdle() 2.EventID: 1023 (9-1-2011 19:44:02) Error message .NET Runtime version 2.0.50727.4952 - Fatal Execution Engine Error (742B851A) (80131506) 3.EventID: 1000 (9-1-2011 19:44:03) Error message Faulting application name: w3wp.exe, version: 7.5.7600.16385, time stamp: 0x4a5bcd2b Faulting module name: mscorwks.dll, version: 2.0.50727.4952, time stamp: 0x4bebd49a Exception code: 0xc0000005 Fault offset: 0x0000c262 Faulting process id: 0x%9 Faulting application start time: 0x%10 Faulting application path: %11 Faulting module path: %12 Report Id: %13 4.EventID: 5011 (9-1-2011 19:44:03) Error message A process serving application pool 'AppPoolName' suffered a fatal communication error with the Windows Process Activation Service. The process id was '2552'. The data field contains the error number. 5.some info: we got the memory.hdmp(234MB) and minidump.mdmp(19.2) from control panel action center but I donot know how to use that :(

    Read the article

  • VPN Error 691 but server says authenticated on server

    - by Andy
    Hello all, I have a problem with a vpn connection on Windows XP SP3 that appears to be related to an account (maybe privilleges or an option that I have missed). When connecting using my account, which is a domain administrator account it will connect to through the vpn fine. However, using an account created for another person they receive Error 691: Username or Password is not valid for this domain. On the domain controller (windows 2003) I see a logon successful message: User DOMAIN\user was granted access. Fully-Qualified-User-Name = int.company.net.au/People/Management/User NAS-IP-Address = 10.30.0.3 NAS-Identifier = not present Client-Friendly-Name = MelbourneCore Client-IP-Address = Router-ip Calling-Station-Identifier = not present NAS-Port-Type = Virtual NAS-Port = 77 Proxy-Policy-Name = Use Windows authentication for all users Authentication-Provider = Windows Authentication-Server = undetermined Policy-Name = Remote VPN Access Authentication-Type = MS-CHAPv1 EAP-Type = Does anyone have any ideas as to where else I should look for finding a solution? If i use the wrong password it gives a logon failure error in the event viewer. Also removing them from the remote access group gives a logon failure error. Nothing appears in the event viewer on the local machine. In the past all that is required is to add them into our Remote Access Users group. Any help?

    Read the article

  • Duplicity on a ReadyNAS

    - by Jason Swett
    Has anyone here run Duplicity on a ReadyNAS? I'm trying but here's what I get: duplicity full --encrypt-key="ABC123" /home/jason/ scp://[email protected]//gob Invalid SSH password Running 'sftp -oServerAliveInterval=15 -oServerAliveCountMax=2 [email protected]' failed (attempt #1) I've also found this post that says the "Invalid SSH password" message doesn't actually mean invalid SSH password. This would make sense because I'm not using an SSH password; I'm using a public key. I can ssh, ftp, sftp and rsync into my ReadyNAS just fine. (Actually, to be more accurate, I can get past authentication with ssh, ftp and sftp but I can't actually do anything past that. Regardless, that's enough to tell me that "Invalid SSH password" is bogus. Rsync works with no problems.) The post I found says the command will work as soon as the directory at the end of your scp command exists, but I don't know how to check for that. I know the share gob exists on my ReadyNAS and I know it's writable because I'm writing to it with rsync. Also, here is the verbose output: Using archive dir: /home/jason/.cache/duplicity/3bdd353b29468311ffa8485160da6873 Using backup name: 3bdd353b29468311ffa8485160da6873 Import of duplicity.backends.rsyncbackend Succeeded Import of duplicity.backends.sshbackend Succeeded Import of duplicity.backends.localbackend Succeeded Import of duplicity.backends.botobackend Succeeded Import of duplicity.backends.cloudfilesbackend Succeeded Import of duplicity.backends.giobackend Succeeded Import of duplicity.backends.hsibackend Succeeded Import of duplicity.backends.imapbackend Succeeded Import of duplicity.backends.ftpbackend Succeeded Import of duplicity.backends.webdavbackend Succeeded Import of duplicity.backends.tahoebackend Succeeded Main action: full ================================================================================ duplicity 0.6.10 (September 19, 2010) Args: /usr/bin/duplicity full --encrypt-key=ABC123 -v9 /home/jason/ scp://[email protected]//gob Linux gob 2.6.35-22-generic #33-Ubuntu SMP Sun Sep 19 20:34:50 UTC 2010 i686 /usr/bin/python 2.6.6 (r266:84292, Sep 15 2010, 15:52:39) [GCC 4.4.5] ================================================================================ Using temporary directory /tmp/duplicity-cridGi-tempdir Registering (mkstemp) temporary file /tmp/duplicity-cridGi-tempdir/mkstemp-ztuF5P-1 Temp has 86334349312 available, backup will use approx 34078720. Running 'sftp -oServerAliveInterval=15 -oServerAliveCountMax=2 [email protected]' (attempt #1) State = sftp, Before = '[email protected]'s' State = sftp, Before = '' Invalid SSH password Running 'sftp -oServerAliveInterval=15 -oServerAliveCountMax=2 [email protected]' failed (attempt #1) Any ideas as to what's going wrong?

    Read the article

  • Postfix Problem (helo/hostname mismatch)!

    - by CuSS
    Hi all, I have a server, and it is running a error for one email only (all other mails in that domain are working). How can i fix it? (The error is above:) May 17 11:43:56 webserver postfix/policyd-weight[5596]: weighted check: IN_DYN_PBL_SPAMHAUS=3.25 NOT_IN_SBL_XBL_SPAMHAUS=-1.5 NOT_IN_SPAMCOP=-1.5 NOT_IN_BL_NJABL=-1.5 DSBL_ORG=ERR(0) CL_IP_NE_HELO=4.75 RESOLVED_IP_IS_NOT_HELO=1.5 HELO_NUMERIC=10.625 (check from: .eticagest. - helo: .[10.0.0.17]. - helo-domain: .17].) FROM_NOT_FAILED_HELO(DOMAIN)=6.25; <client=188.80.139.211> <helo=[10.0.0.17]> <[email protected]> <[email protected]>; rate: 21.875 May 17 11:43:56 webserver postfix/policyd-weight[5596]: decided action=550 Mail appeared to be SPAM or forged. Ask your Mail/DNS-Administrator to correct HELO and DNS MX settings or to get removed from DNSBLs; MTA helo: [10.0.0.17], MTA hostname: bl15-139-211.dsl.telepac.pt[188.80.139.211] (helo/hostname mismatch); <client=188.80.139.211> <helo=[10.0.0.17]> <[email protected]> <[email protected]>; delay: 6s

    Read the article

  • Ubuntu xrandr rotate issue

    - by user83544
    I've just bought a second monitor for my PC which happens to be a pivot monitor. I've already read lots of forums related to my problem but haven't come across a solution - I have the same symptoms as dozens of posts but no matter whatever I try it just doesn't work. I've already changed the xorg.conf file and added in the device section just under Driver "nvidia" the following for my second monitor: Option "RandRRotation" "on" When I save and reboot I try to rotate my screen with the nvidia X server settings by choosing the second monitor and clicking either "left" or "right" for the rotation. It immediately exits the nvidia settings window and does nothing. I tried within the terminal by typing: xrandr -o right I get the following error: X Error of failed request: BadMatch (invalid parameter attributes) Major opcode of failed request: 154 (RANDR) Minor opcode of failed request: 2 (RRSetScreenConfig) Serial number of failed request: 14 Current serial number in output stream: 14 I actually manage to rotate it with Option "Rotate" "CCW" instead of "RandRRotation". The problem with this solution is that you get the second monitor in the right position, but any window you open on that screen is practically unchangeable. You can't change the size nor move it, making it useless for reading PDFs, which is the main reason why I bought this second screen to help me write my thesis. Any help is really appreciated. sudo lshw -c video hiram@hiram-linux:~$ sudo lshw -c video *-display description: VGA compatible controller product: nVidia Corporation vendor: nVidia Corporation physical id: 0 bus info: pci@0000:01:00.0 version: a1 width: 64 bits clock: 33MHz capabilities: pm msi pciexpress vga_controller bus_master cap_list rom configuration: driver=nvidia latency=0 resources: irq:16 memory:f8000000-f9ffffff memory:d8000000-dfffffff memory:d4000000-d7ffffff ioport:dc00(size=12 memory:fbd80000-fbdfffff

    Read the article

  • Unable to install mysql-server in Ubuntu

    - by Arihant
    I am unable to install mysql-server on my ubuntu 9.10 server machine. When using apt-get install mysql-server the output is : # apt-get install mysql-server Reading package lists... Done Building dependency tree Reading state information... Done mysql-server is already the newest version. 0 upgraded, 0 newly installed, 0 to remove and 120 not upgraded. 2 not fully installed or removed. After this operation, 0B of additional disk space will be used. Setting up mysql-server-5.1 (5.1.37-1ubuntu5.4) ... * Stopping MySQL database server Mysqld [ OK ] * Starting MySQL database server mysqld [fail] invoke-rc.d: initscript mysql, action "start" failed. dpkg: error processing mysql-server-5.1 (--configure): subprocess installed post-installation script returned error exit status 1 dpkg: dependency problems prevent configuration of mysql-server: mysql-server depends on mysql-server-5.1; however: Package mysql-server-5.1 is not configured yet. dpkg: error processing mysql-server (--configure): dependency problems - leaving unconfigured No apport report written because the error message indicates its a followup error from a previous failure. Errors were encountered while processing: mysql-server-5.1 mysql-server E: Sub-process /usr/bin/dpkg returned an error code (1) I cant find a satisfactory solution to this problem anywhere. Many sites tell to reinstall it but its not working. Any help will be appreciated. Thank you..

    Read the article

  • LSI MegaRAID LINUX got Optimal after degradation but strange POST message

    - by kesrut
    Linux server box with LSI MegaRAID controller got degraded. But after some time RAID status changed to Optimal. Adapter 0 -- Virtual Drive Information: Virtual Drive: 0 (Target Id: 0) Name : RAID Level : Primary-1, Secondary-0, RAID Level Qualifier-0 Size : 2.727 TB Mirror Data : 2.727 TB State : Optimal Strip Size : 256 KB Number Of Drives per span:2 Span Depth : 3 Default Cache Policy: WriteBack, ReadAdaptive, Cached, No Write Cache if Bad BBU Current Cache Policy: WriteThrough, ReadAdaptive, Cached, No Write Cache if Bad BBU Default Access Policy: Read/Write Current Access Policy: Read/Write Disk Cache Policy : Disk's Default Encryption Type : None Is VD Cached: No But now I'm getting RAID BIOS POST message: Your battery is either charging, bad or missing, and you have VDs configured for write-back mode. Because the battery is not currently usable, these VDs willl actually run in write-through mode until the battery is fully charged or replaced if it is bad or missing. (Image: http://cl.ly/image/1h1O093b1i2d) So may it be battery issue caused problem ? I get information about battery: BatteryType: iBBU Voltage: 4001 mV Current: 0 mA Temperature: 22 C Battery State : Operational BBU Firmware Status: Charging Status : None Voltage : OK Temperature : OK Learn Cycle Requested : No Learn Cycle Active : No Learn Cycle Status : OK Learn Cycle Timeout : No I2c Errors Detected : No Battery Pack Missing : No Battery Replacement required : No Remaining Capacity Low : No Periodic Learn Required : No Transparent Learn : No No space to cache offload : No Pack is about to fail & should be replaced : No Cache Offload premium feature required : No Module microcode update required : No Where can be problem ? I'm disabled alarms, but get them if enabled. But don't know how find root of problem.

    Read the article

  • Using IIS7 as a reverse proxy

    - by Jon
    My question is pretty much identical to the question listed but they did not get an answer as they ended up using Linux as the reverse proxy. http://serverfault.com/questions/55309/using-iis7-as-a-reverse-proxy I need to have IIS the main site and linux (Apache) being the proxied site(s). so I have site1.com (IIS7) site2.com (Linux Apache) they have subdomains of sub1.site1.com sub2.site1.com sub3.site2.com I want all traffic to go to site1.com and to say anything that is site2.com should be proxied to linux box on internal network, (believe ARR can do this but not sure how). I can not have it running as Apache doing the proxying as I need IIS exposed directly. any and all advice would be great. EDIT I think this might help me: <rule name="Canonical Host Name" stopProcessing="true"> <match url="(.*)" /> <conditions> <add input="{HTTP_HOST}" negate="true" pattern="^cto\.com$" /> <add input="{HTTP_HOST}" negate="true" pattern="^antoniochagoury\.com$" /> <add input="{HTTP_HOST}" negate="true" pattern="www.antoniochagoury\.com$" /> </conditions> <action type="Redirect" url="http://www.cto20.com/{R:1}" redirectType="Permanent" /> </rule> from: http://www.cto20.com/post/Tips-Tricks-3-URL-Rewriting-Rules-Everyone-Should-Use.aspx I will have a look at this when I have access to the IIS7 box. Thanks

    Read the article