Search Results

Search found 14693 results on 588 pages for 'azure storage tables'.

Page 56/588 | < Previous Page | 52 53 54 55 56 57 58 59 60 61 62 63  | Next Page >

  • SQL SERVER – Introduction to SQL Server 2014 In-Memory OLTP

    - by Pinal Dave
    In SQL Server 2014 Microsoft has introduced a new database engine component called In-Memory OLTP aka project “Hekaton” which is fully integrated into the SQL Server Database Engine. It is optimized for OLTP workloads accessing memory resident data. In-memory OLTP helps us create memory optimized tables which in turn offer significant performance improvement for our typical OLTP workload. The main objective of memory optimized table is to ensure that highly transactional tables could live in memory and remain in memory forever without even losing out a single record. The most significant part is that it still supports majority of our Transact-SQL statement. Transact-SQL stored procedures can be compiled to machine code for further performance improvements on memory-optimized tables. This engine is designed to ensure higher concurrency and minimal blocking. In-Memory OLTP alleviates the issue of locking, using a new type of multi-version optimistic concurrency control. It also substantially reduces waiting for log writes by generating far less log data and needing fewer log writes. Points to remember Memory-optimized tables refer to tables using the new data structures and key words added as part of In-Memory OLTP. Disk-based tables refer to your normal tables which we used to create in SQL Server since its inception. These tables use a fixed size 8 KB pages that need to be read from and written to disk as a unit. Natively compiled stored procedures refer to an object Type which is new and is supported by in-memory OLTP engine which convert it into machine code, which can further improve the data access performance for memory –optimized tables. Natively compiled stored procedures can only reference memory-optimized tables, they can’t be used to reference any disk –based table. Interpreted Transact-SQL stored procedures, which is what SQL Server has always used. Cross-container transactions refer to transactions that reference both memory-optimized tables and disk-based tables. Interop refers to interpreted Transact-SQL that references memory-optimized tables. Using In-Memory OLTP In-Memory OLTP engine has been available as part of SQL Server 2014 since June 2013 CTPs. Installation of In-Memory OLTP is part of the SQL Server setup application. The In-Memory OLTP components can only be installed with a 64-bit edition of SQL Server 2014 hence they are not available with 32-bit editions. Creating Databases Any database that will store memory-optimized tables must have a MEMORY_OPTIMIZED_DATA filegroup. This filegroup is specifically designed to store the checkpoint files needed by SQL Server to recover the memory-optimized tables, and although the syntax for creating the filegroup is almost the same as for creating a regular filestream filegroup, it must also specify the option CONTAINS MEMORY_OPTIMIZED_DATA. Here is an example of a CREATE DATABASE statement for a database that can support memory-optimized tables: CREATE DATABASE InMemoryDB ON PRIMARY(NAME = [InMemoryDB_data], FILENAME = 'D:\data\InMemoryDB_data.mdf', size=500MB), FILEGROUP [SampleDB_mod_fg] CONTAINS MEMORY_OPTIMIZED_DATA (NAME = [InMemoryDB_mod_dir], FILENAME = 'S:\data\InMemoryDB_mod_dir'), (NAME = [InMemoryDB_mod_dir], FILENAME = 'R:\data\InMemoryDB_mod_dir') LOG ON (name = [SampleDB_log], Filename='L:\log\InMemoryDB_log.ldf', size=500MB) COLLATE Latin1_General_100_BIN2; Above example code creates files on three different drives (D:  S: and R:) for the data files and in memory storage so if you would like to run this code kindly change the drive and folder locations as per your convenience. Also notice that binary collation was specified as Windows (non-SQL). BIN2 collation is the only collation support at this point for any indexes on memory optimized tables. It is also possible to add a MEMORY_OPTIMIZED_DATA file group to an existing database, use the below command to achieve the same. ALTER DATABASE AdventureWorks2012 ADD FILEGROUP hekaton_mod CONTAINS MEMORY_OPTIMIZED_DATA; GO ALTER DATABASE AdventureWorks2012 ADD FILE (NAME='hekaton_mod', FILENAME='S:\data\hekaton_mod') TO FILEGROUP hekaton_mod; GO Creating Tables There is no major syntactical difference between creating a disk based table or a memory –optimized table but yes there are a few restrictions and a few new essential extensions. Essentially any memory-optimized table should use the MEMORY_OPTIMIZED = ON clause as shown in the Create Table query example. DURABILITY clause (SCHEMA_AND_DATA or SCHEMA_ONLY) Memory-optimized table should always be defined with a DURABILITY value which can be either SCHEMA_AND_DATA or  SCHEMA_ONLY the former being the default. A memory-optimized table defined with DURABILITY=SCHEMA_ONLY will not persist the data to disk which means the data durability is compromised whereas DURABILITY= SCHEMA_AND_DATA ensures that data is also persisted along with the schema. Indexing Memory Optimized Table A memory-optimized table must always have an index for all tables created with DURABILITY= SCHEMA_AND_DATA and this can be achieved by declaring a PRIMARY KEY Constraint at the time of creating a table. The following example shows a PRIMARY KEY index created as a HASH index, for which a bucket count must also be specified. CREATE TABLE Mem_Table ( [Name] VARCHAR(32) NOT NULL PRIMARY KEY NONCLUSTERED HASH WITH (BUCKET_COUNT = 100000), [City] VARCHAR(32) NULL, [State_Province] VARCHAR(32) NULL, [LastModified] DATETIME NOT NULL, ) WITH (MEMORY_OPTIMIZED = ON, DURABILITY = SCHEMA_AND_DATA); Now as you can see in the above query example we have used the clause MEMORY_OPTIMIZED = ON to make sure that it is considered as a memory optimized table and not just a normal table and also used the DURABILITY Clause= SCHEMA_AND_DATA which means it will persist data along with metadata and also you can notice this table has a PRIMARY KEY mentioned upfront which is also a mandatory clause for memory-optimized tables. We will talk more about HASH Indexes and BUCKET_COUNT in later articles on this topic which will be focusing more on Row and Index storage on Memory-Optimized tables. So stay tuned for that as well. Now as we covered the basics of Memory Optimized tables and understood the key things to remember while using memory optimized tables, let’s explore more using examples to understand the Performance gains using memory-optimized tables. I will be using the database which i created earlier in this article i.e. InMemoryDB in the below Demo Exercise. USE InMemoryDB GO -- Creating a disk based table CREATE TABLE dbo.Disktable ( Id INT IDENTITY, Name CHAR(40) ) GO CREATE NONCLUSTERED INDEX IX_ID ON dbo.Disktable (Id) GO -- Creating a memory optimized table with similar structure and DURABILITY = SCHEMA_AND_DATA CREATE TABLE dbo.Memorytable_durable ( Id INT NOT NULL PRIMARY KEY NONCLUSTERED Hash WITH (bucket_count =1000000), Name CHAR(40) ) WITH (MEMORY_OPTIMIZED = ON, DURABILITY = SCHEMA_AND_DATA) GO -- Creating an another memory optimized table with similar structure but DURABILITY = SCHEMA_Only CREATE TABLE dbo.Memorytable_nondurable ( Id INT NOT NULL PRIMARY KEY NONCLUSTERED Hash WITH (bucket_count =1000000), Name CHAR(40) ) WITH (MEMORY_OPTIMIZED = ON, DURABILITY = SCHEMA_only) GO -- Now insert 100000 records in dbo.Disktable and observe the Time Taken DECLARE @i_t bigint SET @i_t =1 WHILE @i_t<= 100000 BEGIN INSERT INTO dbo.Disktable(Name) VALUES('sachin' + CONVERT(VARCHAR,@i_t)) SET @i_t+=1 END -- Do the same inserts for Memory table dbo.Memorytable_durable and observe the Time Taken DECLARE @i_t bigint SET @i_t =1 WHILE @i_t<= 100000 BEGIN INSERT INTO dbo.Memorytable_durable VALUES(@i_t, 'sachin' + CONVERT(VARCHAR,@i_t)) SET @i_t+=1 END -- Now finally do the same inserts for Memory table dbo.Memorytable_nondurable and observe the Time Taken DECLARE @i_t bigint SET @i_t =1 WHILE @i_t<= 100000 BEGIN INSERT INTO dbo.Memorytable_nondurable VALUES(@i_t, 'sachin' + CONVERT(VARCHAR,@i_t)) SET @i_t+=1 END The above 3 Inserts took 1.20 minutes, 54 secs, and 2 secs respectively to insert 100000 records on my machine with 8 Gb RAM. This proves the point that memory-optimized tables can definitely help businesses achieve better performance for their highly transactional business table and memory- optimized tables with Durability SCHEMA_ONLY is even faster as it does not bother persisting its data to disk which makes it supremely fast. Koenig Solutions is one of the few organizations which offer IT training on SQL Server 2014 and all its updates. Now, I leave the decision on using memory_Optimized tables on you, I hope you like this article and it helped you understand  the fundamentals of IN-Memory OLTP . Reference: Pinal Dave (http://blog.sqlauthority.com)Filed under: PostADay, SQL, SQL Authority, SQL Performance, SQL Query, SQL Server, SQL Tips and Tricks, T SQL Tagged: Koenig

    Read the article

  • Export mysql database tables to php code to create same tables in other database?

    - by chefnelone
    How do I Export mysql database tables to php code so that it allows me to create and populate same tables in other database? I have a local database, I exported to sql syntax, then I get something like: CREATE TABLE `boletinSuscritos` ( `id` int(11) NOT NULL AUTO_INCREMENT, `name` varchar(120) NOT NULL, `email` varchar(120) NOT NULL, `date` timestamp NOT NULL DEFAULT CURRENT_TIMESTAMP, PRIMARY KEY (`id`) ) ENGINE=MyISAM DEFAULT CHARSET=utf8 AUTO_INCREMENT=3 ; INSERT INTO `boletinSuscritos` VALUES(1, 'walter', '[email protected]', '2010-03-24 12:53:12'); INSERT INTO `boletinSuscritos` VALUES(2, 'Paco', '[email protected]', '2010-03-24 12:56:56'); but I need it to be: (Is there any way to export the tables in this way) $sql = "CREATE TABLE boletinSuscritos ( id int(11) NOT NULL AUTO_INCREMENT, name varchar(120) NOT NULL, email varchar(120) NOT NULL, date timestamp NOT NULL DEFAULT CURRENT_TIMESTAMP, PRIMARY KEY ( id ) ) ENGINE=MyISAM DEFAULT CHARSET=utf8 AUTO_INCREMENT=3 )"; mysql_query($sql,$conexion); mysql_query("INSERT INTO boletinSuscritos VALUES(1, 'walter', '[email protected]', '2010-03-24 12:53:12')"); mysql_query("INSERT INTO boletinSuscritos VALUES(2, 'Paco', '[email protected]', '2010-03-24 12:56:56')");

    Read the article

  • Validating Petabytes of Data with Regularity and Thoroughness

    - by rickramsey
    by Brian Zents When former Intel CEO Andy Grove said “only the paranoid survive,” he wasn’t necessarily talking about tape storage administrators, but it’s a lesson they’ve learned well. After all, tape storage is the last line of defense to prevent data loss, so tape administrators are extra cautious in making sure their data is secure. Not surprisingly, we are often asked for ways to validate tape media and the files on them. In the past, an administrator could validate the media, but doing so was often tedious or disruptive or both. The debut of the Data Integrity Validation (DIV) and Library Media Validation (LMV) features in the Oracle T10000C drive helped eliminate many of these pains. Also available with the Oracle T10000D drive, these features use hardware-assisted CRC checks that not only ensure the data is written correctly the first time, but also do so much more efficiently. Traditionally, a CRC check takes at least 25 seconds per 4GB file with a 2:1 compression ratio, but the T10000C/D drives can reduce the check to a maximum of nine seconds because the entire check is contained within the drive. No data needs to be sent to a host application. A time savings of at least 64 percent is extremely beneficial over the course of checking an entire 8.5TB T10000D tape. While the DIV and LMV features are better than anything else out there, what storage administrators really need is a way to check petabytes of data with regularity and thoroughness. With the launch of Oracle StorageTek Tape Analytics (STA) 2.0 in April, there is finally a solution that addresses this longstanding need. STA bundles these features into one interface to automate all media validation activities across all Oracle SL3000 and SL8500 tape libraries in an environment. And best of all, the validation process can be associated with the health checks an administrator would be doing already through STA. In fact, STA validates the media based on any of the following policies: Random Selection – Randomly selects media for validation whenever a validation drive in the standalone library or library complex is available. Media Health = Action – Selects media that have had a specified number of successive exchanges resulting in an Exchange Media Health of “Action.” You can specify from one to five exchanges. Media Health = Evaluate – Selects media that have had a specified number of successive exchanges resulting in an Exchange Media Health of “Evaluate.” You can specify from one to five exchanges. Media Health = Monitor – Selects media that have had a specified number of successive exchanges resulting in an Exchange Media Health of “Monitor.” You can specify from one to five exchanges. Extended Period of Non-Use – Selects media that have not had an exchange for a specified number of days. You can specify from 365 to 1,095 days (one to three years). Newly Entered – Selects media that have recently been entered into the library. Bad MIR Detected – Selects media with an exchange resulting in a “Bad MIR Detected” error. A bad media information record (MIR) indicates degraded high-speed access on the media. To avoid disrupting host operations, an administrator designates certain drives for media validation operations. If a host requests a file from media currently being validated, the host’s request takes priority. To ensure that the administrator really knows it is the media that is bad, as opposed to the drive, STA includes drive calibration and qualification features. In addition, validation requests can be re-prioritized or cancelled as needed. To ensure that a specific tape isn’t validated too often, STA prevents a tape from being validated twice within 24 hours via one of the policies described above. A tape can be validated more often if the administrator manually initiates the validation. When the validations are complete, STA reports the results. STA does not report simply a “good” or “bad” status. It also reports if media is even degraded so the administrator can migrate the data before there is a true failure. From that point, the administrators’ paranoia is relieved, as they have the necessary information to make a sound decision about the health of the tapes in their environment. About the Photograph Photograph taken by Rick Ramsey in Death Valley, California, May 2014 - Brian Follow OTN Garage on: Web | Facebook | Twitter | YouTube

    Read the article

  • How to Quickly Encrypt Removable Storage Devices with Ubuntu

    - by Chris Hoffman
    Ubuntu can quickly encrypt USB flash drives and external hard drives. You’ll be prompted for your passphrase each time you connect the drive to your computer – your private data will be secure, even if you misplace the drive. Ubuntu’s Disk Utility uses LUKS (Linux Unified Key Setup) encryption, which may not be compatible with other operating systems. However, the drive will be plug-and-play with any Linux system running the GNOME desktop. HTG Explains: What Is RSS and How Can I Benefit From Using It? HTG Explains: Why You Only Have to Wipe a Disk Once to Erase It HTG Explains: Learn How Websites Are Tracking You Online

    Read the article

  • Part 4, Getting the conversion tables ready for CS to DNN

    - by Chris Hammond
    This is the fourth post in a series of blog posts about converting from CommunityServer to DotNetNuke. A brief background: I had a number of websites running on CommunityServer 2.1, I decided it was finally time to ditch CommunityServer due to the change in their licensing model and pricing that made it not good for the small guy. This series of blog posts is about how to convert your CommunityServer based sites to DotNetNuke . Previous Posts: Part 1: An Introduction Part 2: DotNetNuke Installation...(read more)

    Read the article

  • The internal storage of a SMALLDATETIME value

    - by Peter Larsson
    SELECT  [Now],         BinaryFormat,         SUBSTRING(BinaryFormat, 1, 2) AS DayPart,         SUBSTRING(BinaryFormat, 3, 2) AS TimePart,         CAST(SUBSTRING(BinaryFormat, 1, 2) AS INT) AS [Days],         DATEADD(DAY, CAST(SUBSTRING(BinaryFormat, 1, 2) AS INT), 0) AS [Today],         SUBSTRING(BinaryFormat, 3, 2) AS [Ticks],         DATEADD(MINUTE, CAST(SUBSTRING(BinaryFormat, 3, 2) AS SMALLINT), 0) AS Peso FROM    (             SELECT  CAST(GETDATE() AS SMALLDATETIME) AS [Now],                     CAST(CAST(GETDATE() AS SMALLDATETIME) AS BINARY(4)) AS BinaryFormat         ) AS d

    Read the article

  • The internal storage of a DATETIME value

    - by Peter Larsson
    SELECT  [Now],         BinaryFormat,         SUBSTRING(BinaryFormat, 1, 4) AS DayPart,         SUBSTRING(BinaryFormat, 5, 4) AS TimePart,         CAST(SUBSTRING(BinaryFormat, 1, 4) AS INT) AS [Days],         DATEADD(DAY, CAST(SUBSTRING(BinaryFormat, 1, 4) AS INT), 0) AS [Today],         CAST(SUBSTRING(BinaryFormat, 5, 4) AS INT) AS [Ticks],         DATEADD(MILLISECOND, 1000.E / 300.E * CAST(SUBSTRING(BinaryFormat, 5, 4) AS INT), 0) AS Peso FROM    (             SELECT  GETDATE() AS [Now],                     CAST(GETDATE() AS BINARY(8)) AS BinaryFormat         ) AS d

    Read the article

  • How to create a PeopleCode Application Package/Application Class using PeopleTools Tables

    - by Andreea Vaduva
    This article describes how - in PeopleCode (Release PeopleTools 8.50) - to enable a grid without enabling each static column, using a dynamic Application Class. The goal is to disable the following grid with three columns “Effort Date”, ”Effort Amount” and “Charge Back” , when the Check Box “Finished with task” is selected , without referencing each static column; this PeopleCode could be used dynamically with any grid. If the check box “Finished with task” is cleared, the content of the grid columns is editable (and the buttons “+” and “-“ are available): So, you create an Application Package “CLASS_EXTENSIONS” that contains an Application Class “EWK_ROWSET”. This Application Class is defined with Class extends “ Rowset” and you add two news properties “Enabled” and “Visible”: After creating this Application Class, you use it in two PeopleCode Events : Rowinit and FieldChange : This code is very ‘simple’, you write only one command : ” &ERS2.Enabled = False” → and the entire grid is “Enabled”… and you can use this code with any Grid! So, the complete PeopleCode to create the Application Package is (with explanation in [….]) : ******Package CLASS_EXTENSIONS : [Name of the Package: CLASS_EXTENSIONS] --Beginning of the declaration part------------------------------------------------------------------------------ class EWK_ROWSET extends Rowset; [Definition Class EWK_ROWSET as a subclass of Class Rowset] method EWK_ROWSET(&RS As Rowset); [Constructor is the Method with the same name of the Class] property boolean Visible get set; property boolean Enabled get set; [Definition of the property “Enabled” in read/write] private [Before the word “private”, all the declarations are publics] method SetDisplay(&DisplaySW As boolean, &PropName As string, &ChildSW As boolean); instance boolean &EnSW; instance boolean &VisSW; instance Rowset &NextChildRS; instance Row &NextRow; instance Record &NextRec; instance Field &NextFld; instance integer &RowCnt, &RecCnt, &FldCnt, &ChildRSCnt; instance integer &i, &j, &k; instance CLASS_EXTENSIONS:EWK_ROWSET &ERSChild; [For recursion] Constant &VisibleProperty = "VISIBLE"; Constant &EnabledProperty = "ENABLED"; end-class; --End of the declaration part------------------------------------------------------------------------------ method EWK_ROWSET [The Constructor] /+ &RS as Rowset +/ %Super = &RS; end-method; get Enabled /+ Returns Boolean +/; Return &EnSW; end-get; set Enabled /+ &NewValue as Boolean +/; &EnSW = &NewValue; %This.InsertEnabled=&EnSW; %This.DeleteEnabled=&EnSW; %This.SetDisplay(&EnSW, &EnabledProperty, False); [This method is called when you set this property] end-set; get Visible /+ Returns Boolean +/; Return &VisSW; end-get; set Visible /+ &NewValue as Boolean +/; &VisSW = &NewValue; %This.SetDisplay(&VisSW, &VisibleProperty, False); end-set; method SetDisplay [The most important PeopleCode Method] /+ &DisplaySW as Boolean, +/ /+ &PropName as String, +/ /+ &ChildSW as Boolean +/ [Not used in our example] &RowCnt = %This.ActiveRowCount; &NextRow = %This.GetRow(1); [To know the structure of a line ] &RecCnt = &NextRow.RecordCount; For &i = 1 To &RowCnt [Loop for each Line] &NextRow = %This.GetRow(&i); For &j = 1 To &RecCnt [Loop for each Record] &NextRec = &NextRow.GetRecord(&j); &FldCnt = &NextRec.FieldCount; For &k = 1 To &FldCnt [Loop for each Field/Record] &NextFld = &NextRec.GetField(&k); Evaluate Upper(&PropName) When = &VisibleProperty &NextFld.Visible = &DisplaySW; Break; When = &EnabledProperty; &NextFld.Enabled = &DisplaySW; [Enable each Field/Record] Break; When-Other Error "Invalid display property; Must be either VISIBLE or ENABLED" End-Evaluate; End-For; End-For; If &ChildSW = True Then [If recursion] &ChildRSCnt = &NextRow.ChildCount; For &j = 1 To &ChildRSCnt [Loop for each Rowset child] &NextChildRS = &NextRow.GetRowset(&j); &ERSChild = create CLASS_EXTENSIONS:EWK_ROWSET(&NextChildRS); &ERSChild.SetDisplay(&DisplaySW, &PropName, &ChildSW); [For each Rowset child, call Method SetDisplay with the same parameters used with the Rowset parent] End-For; End-If; End-For; end-method; ******End of the Package CLASS_EXTENSIONS:[Name of the Package: CLASS_EXTENSIONS] About the Author: Pascal Thaler joined Oracle University in 2005 where he is a Senior Instructor. His area of expertise is Oracle Peoplesoft Technology and he delivers the following courses: For Developers: PeopleTools Overview, PeopleTools I &II, Batch Application Engine, Language Oriented Object PeopleCode, Administration Security For Administrators : Server Administration & Installation, Database Upgrade & Data Management Tools For Interface Users: Integration Broker (Web Service)

    Read the article

  • Extracting Data from a Source System to History Tables

    - by Derek D.
    This is a topic I find very little information written about, however it is very important that the method for extracting data be done in a way that does not hinder performance of the source system.  In this example, the goal is to extract data from a source system, into another database (or server) all [...]

    Read the article

  • winusb formatting and installation error, lost data storage on 32gb flash drive

    - by Cary Felton
    i recently purchased a pny brand 32gb usb drive to use for configuring a dual boot on my computer, and for hdd files backup. i also recently installed zorin os 6.1 as my main os, and then downloaded winusb for linux, and set it to install the iso for windows 8 release preview as the activation code is still good untill jan.2013, and there was an error on the installation. i rebooted the computer, plugged in the usb drive, and i went from 32gb usable space to somehow having a partitioned drive (mounted as two separate drives) one being 3.7gb, and the other being i believe 25gb or so... i then formatted the drive with gparted back to fat32, and it still read as a windows usb with the installation files on it still? so then i took my usb drive to my library which runs windows 8, i installed bootice, and completely reformatted my usb drive, and somehow it is usable, but still not perfect. it reads i only have 29.9gb usable space... i have already thought of the non usable area, and that doesnt account for this error as when i first bought the drive and plugged it in on linux, it read total drive space was 32.2 and exactly 32 was usable. somehow i am short by 2gb of space which is very critical for what i am doing. i love linux, i only needed windows for bluray playback with daplayer as it wont work well in wine, but if i keep losing space on my usb drives im afraid ill have to switch back. any help would be appreciated as i already visited pny's site, and they have no support for this issue, and im not that fond of partitions, file systems, or formatting.

    Read the article

  • SQL SERVER – Identifying Column Data Type of uniqueidentifier without Querying System Tables

    - by pinaldave
    I love interesting conversations with related to SQL Server. One of my friends Madhivanan always comes up with an interesting point of conversation. Here is one of the conversation between us. I am very confident this blog post will for sure enable you with some new knowledge. Madhi: How do I know if any table has a uniqueidentifier column used in it? Pinal:  I am sure you know that you can do it through some DMV or catalogue views. Madhi: I know that but how can we do that without using DMV or catalogue views? Pinal: Hm… what can I use? Madhi: You can use table name. Pinal: Easy, just say SELECT YourUniqueIdentCol FROM Table. Madhi: Hold on, the question seems to be not clear to you – you do know the name of the column. The matter of the fact, you do not know if the table has uniqueidentifier column. Only information you have is table name. Pinal: Madhi, this seems like you are changing the question when I am close to answer. Madhi: Well, are you clear now? Let me say it again – How do I know if any table has a uniqueidentifier column and what is its value without using any DMV or System Catalogues? Only information you know is table name and you are allowed to return any kind of error if table does not have uniqueidentifier column. Pinal: Do you know the answer? Madhi: Yes. I just wanted to test your knowledge about SQL. Pinal: I will have to think. Let me accept I do not know it right away. Can you share the answer please? Madhi: I won! Here it goes! Pinal: When I have friends like you – who needs enemies? Madhi: (laughter which did not stop for a minute). CREATE TABLE t ( GuidCol UNIQUEIDENTIFIER DEFAULT newsequentialid() ROWGUIDCOL, data VARCHAR(60) ) INSERT INTO t (data) SELECT 'test' INSERT INTO t (data) SELECT 'test1' SELECT $rowguid FROM t DROP TABLE t This is indeed very interesting to me. Please note that this is not the optimal way and there will be many other ways to retrieve uniqueidentifier name and value. What I learned from this was if I am in a rush to check if the table has uniqueidentifier and I do not know the name of the same, I can use SELECT TOP (1) $rowguid and quickly know the name of the column. I can later use the same columnname in my query. Madhi did teach me this new trick. Did you know this? What are other ways to get the check uniqueidentifier column existence in a database? Reference: Pinal Dave (http://blog.SQLAuthority.com) Filed under: PostADay, SQL, SQL Authority, SQL Puzzle, SQL Query, SQL Server, SQL Server Management Studio, SQL Tips and Tricks, T SQL, Technology

    Read the article

  • VS 2010, Silverlight, WP 7, Azure, F#, jQuery & more take Center Stage at India's Definitive Microso

    Microsoft has announced a slew of new and exciting releases that will help you take your code to the next level in 2010. As one of the longest running independent developer conferences in India, GIDS.NET at the Great Indian Developer Summit 2010 is uniquely positioned to provide a blend of practical, pragmatic and immediately applicable knowledge and a glimpse of the future of technology. At GIDS.NET, 0n 20 April 2010 in Bangalore, expert speakers will address a wide range of topics, including .NET...Did you know that DotNetSlackers also publishes .net articles written by top known .net Authors? We already have over 80 articles in several categories including Silverlight. Take a look: here.

    Read the article

  • Auto Save and Auto Load Game onto the Device's Storage Concept Question

    - by David Dimalanta
    I'm trying to make a simple app that will test the save and load state. Is it a good idea to make an app that has an auto save and load game feature only every time the newbies open the first app then continues it on the other day? I tried making a sprite that is moving, starting at the center. When I close and re-open the app, the sprite goes back to the center instead of the last coordinate where the sprite land on this part (i.e. at the top). The thing I want to know how the sequence of saving and loading goes like this: I open the app The starting sprite at the center. It displays a coordinate of the sprite plus number of times does the sprite move. I exit the app that automatically saves the game without notice. Finally, when I re-opened it, it automatically loads the game retaining the number of times the sprite move, coordinates, and the sprite's area landed. These steps above are similar, but not the sprite movement test app, to the sequence of saving and loading the game's level and record in Jewel Stackers for the Android app. And, by default, if there is no SD card in any tab or phone that runs on Android, does it automatically save/load onto the internal drive or the APK file itself? Is it also useful to use auto save and auto load feature for protecting and fetching informations (i.e. fastest time, last time where the sprite is located via coordinates, etc.)?

    Read the article

  • Making game constants/tables available to game logic classes/routines in a modular manner

    - by Extrakun
    Suppose I have a game where there are several predefined constants and charts (a XP chart, cost of goods and so on). Those could be defined at runtime, or load from files at start-up. The question is how should those logic routines access the constants and charts? For example, I could try using global variables, but that cause all classes relying on the variables to be tightly coupled with them.

    Read the article

< Previous Page | 52 53 54 55 56 57 58 59 60 61 62 63  | Next Page >