  • Problem with SQL connection on virtualised machines

    - by Mike Selby
    We have just virtualised our web servers but are experiencing problems when trying to connect with the existing DB server. The error message that is being returned from the virtual machines is as follows: A connection was successfully established with the server, but then an error occurred during the login process. (provider: TCP Provider, error: 0 - The specified network name is no longer available.) Any help would be much appreciated - Many thanks in advance.

    Read the article

  • SCCM deploy from VMware XP image

    - by HannesFostie
    We recently set up the latest version of SCCM and I managed to capture a .wim image from a virtual machine (build and capture task sequence). I want to use this .wim file to deploy winXP to different hardware, and therefor need to add device drivers to the task sequence. I created a driver package per laptop type, and deployed for the first time. However, I am getting a BSOD (0x00007B) which leads me to believe theres a problem with the storage drivers. After adjusting the task sequence to try and point to the mass storage drivers (which are applied at F6, I suppose) I do not get a list of compatible drivers (the list is empty). I looked around, and found some issues regarding hdc class drivers that are not recognized as mass storage drivers. The workaround suggested changing the INF file to make the driver a SCSIAdapter class driver, and importing these again, but to no avail. The list remains empty. Any help is much appreciated

    Read the article

  • Monitoring Dell/HP Servers Running ESXi (Free)

    - by Untalented
    What are you all doing to monitor ESXi servers that run the free edition? With the lack of SNMP support, it seems fairly limited to me. What'd I'd like to be able to do is get some type of alert when a drive or other hardware fails. I've seen a few articles on getting OpenManage installed on an ESXi box (to rebuild an array), but it seems to be quite a pain as well. Even if I get OpenManage working, I won't have alerts without SNMP. Any comments, input, or guidance would be greatly appreciated.

    Read the article

  • Question about VMWare thin provisioning

    - by Datapimp23
    I'm playing around with virtual disks and thin provisioning and have a question about it. I've created several disks and allocated space to with thin provisioning. Is it possible to allocate more disk space than the maximum amount of the datastore space. So that for example, my VM's will stop functioning when the disks slowly start filling up?

    Read the article

  • iSCSI performance questions

    - by RyanLambert
    Hi everyone, apologies for the long-winded post in advance... Attempting to troubleshoot some iSCSI sluggishness on a brand new vSphere deployment (still in test). Layout is as such: 3 VSphere hosts, each with 2x 10GB NICs plugged into a pair of Nexus 5020s with a 10gig back-to-back between them. NICs are port-channeled in an active/active redundant fashion (using vPC-mac pinning for those of you familiar with N1KV) Both NICs carry service console, vmotion, iSCSI, and guest traffic. iSCSI is on a single subnet/single VLAN that is not routed through our IP network (strictly layer2) Had this been a 1gig deployment, we probably would have split the iSCSI traffic off onto separate NICs, but the price/port gets rather ridiculous when you start throwing 4+ NICs to a server in a 10gigabit infrastructure, and I'm not really convinced it's necessary. Open to dialogue/tech facts re: this, though. At this point even a single VM guest will boot slowly to iSCSI storage (EMC CX4 on the same Nexus 5020 10gig switches), and restores of VMs from iSCSI take about twice as long as we'd expect them to. Our server folks mentioned that if we split the iSCSI off onto its own NIC, performance seems significantly better. From a network perspective, I've run through the variables I can think of (port configuration errors, MTU problems, congestion etc.) and I'm coming up dry. There really is no other traffic on these hosts other than the very specific test being performed at the time. Important thing to note is that guest traffic works just fine... it seems storage is the only thing affected by whatever gremlin exists. Concluding that we're not 'overutilizing' the network infrastructure since we're doing hardly anything, I'm just looking for some helpful tips/ideas we can use to resolve this... preferably without hurling extra 10gig NICs that are going to sit around 10% utilization while we've got 70+% left on our others.

    Read the article

  • Can you run Android 2.2 Froyo or 2.3 Gingerbread in a VM?

    - by Josh B
    I came across a how-to guide for running Android 1.7 in a virtual machine (VirtualBox), but 1.7 is old. I haven't been able to find a Android 2.2 or 2.3 image anywhere, does anyone have any ideas on how to virtualize newer Android OS's? Preferably a free virtualization solution like VirtualBox. Here is the link about virtualizing 1.7: http://osxdaily.com/2010/12/14/run-android-using-a-virtual-machine-on-a-mac-or-windows-pc/ They send you to here to download Android disk images: http://virtualboxes.org/images/android-x86/ But I can't find anything newer than 1.7, anyone have any ideas? Is this considered illegal or piracy is that why there are no images available? Thanks for help!

    Read the article

  • Slow Write Speed on ESXi host

    - by Gregg Leventhal
    I have an ESXi 5.0 free host with an internal datastore of 7.2K 5 disk RAID 5 using a PERC 710 mini RAID controller in a Dell Poweredge R620 Server with 32GB Ram and a 12 Core Xeon. I seem to get slow write speeds in the guests so I checked out ESXTOP and I see 15MB/s write speed there on this host, which is comprable to the guests. What could be causing such horrible write speeds? Is RAID 5 really this slow to write??

    Read the article

  • How do I access an Ubuntu VirtualBox guest at a static IP from an OS X host?

    - by David Siegel
    How does one configure an Ubuntu guest to use a static IP that's visible to an OS X host, and ensure that the static IP is independent of the host's network configuration? I previously used bridged networking for my guest, but I'm constantly moving my host between networks so the guest IP is always different. First, I tried setting the guest network configuration to NAT and forwarding host port 1022 to guest port 22, so I could at least ssh to a fixed address (localhost:1022): $ VBoxManage setextradata "Ubuntu Server" "VBoxInternal/Devices/e1000/0/LUN#0/Config/SSH/Protocol" "TCP" $ VBoxManage setextradata "Ubuntu Server" "VBoxInternal/Devices/e1000/0/LUN#0/Config/SSH/GuestPort" 22 $ VBoxManage setextradata "Ubuntu Server" "VBoxInternal/Devices/e1000/0/LUN#0/Config/SSH/HostPort" 1022 Then, $ ssh localhost -p 1022 ssh: connect to host localhost port 1022: Connection refused But this didn't work (guest has no network access with NAT and OS X refused the connection, as you can see). I'd love a general solution that would let me communicate with my guest at a fixed IP.

    Read the article

  • Internet explorer crashes in VM Player

    - by Vikram
    My internet explorer is hanging whenever I open it, and all the buttons under Tools menu got disabled. and it always says Connecting... but it will never connects. So I debugged and came to know that IE is opening on some user on VMPlayer not as the user logged in, in my case Administrator. When I open it as 'Run as administrator' it opens fine. By the way I logged into my system as administrator not as a normal user, but still it opens with some other user. Can some one solve this issue. Thanks

    Read the article

  • Cannot Join a Domain on VM

    - by arvind0007
    Hi Guys. I have installed Windows 2003 server R2 on a VM. This VM is running on Windows XP PRO. When i try to make this XP Pro PC join the domain on the VM it tries to locate the server and gives me the following error message " The specified network name is no longer available", despite the fact that i can still see this domain on my network. can anyone help with this please. This is the very first time i am trying connecting a client to a VM server so hope am not doing anything wrong.. thanks

    Read the article

  • connect to paltalk server using a proxy

    - by user40026
    Hi I want to use paltalk, which is a kind of chat software, but the ports that this applications uses are closed in my country. What I need to do is to use a proxy server. Unfortunately the software itself does not provide a proxy setting. I though it would be possible to run paltalk on an O.S. installed on a virtual machine (say virtualbox) and configure the network setting of virtual machine to direct all its traffic through a proxy on host Operating system, but I could not find a way to do so neither. can anyone please help me?

    Read the article

  • Simple NAT router for ESX

    - by Evan M.
    Hi Guys, I'm looking for a simple virtual appliance that I can deploy to my ESX environment to use as a virtual NAT router / firewall to create an isolated network that I can easily give internet access too. Basic setup: ESX Host, has 2 vswitches configured: 1 is connected to the physical LAN, the other is isolated. I need an appliance that I can add 2 vNICs to, and attach one to the isolated vSwitch, the other to the LAN, to give the isolated network outbound access (so it can reach the internet). Anyone have an appliance that I can setup quickly to do so? Thanks.

    Read the article

  • ESXi Static IP setup with gateway on different subnet

    - by Erik Nelson
    I've got an ESXi server that I'm trying to assign a static IP to. I'm having trouble setting the gateway because (I presume) the gateway is on a different subnet. I've been able to accomplish this task on normal Linux servers by doing the following: route add 172.50.99.254 eth0 route add -net default gw 172.50.99.254 eth0 Now using the GUI config tools for ESXi I've tried setting the following IP: 172.50.5.151 Netmask: 255.255.252.0 Gateway: 172.50.99.254 The gateway does not stick, and when I try to add the gateway manually using esxcfg-route it says it has no route to the gateway IP. How can I get this static IP set correctly? (I don't have any control over the network setup).

    Read the article

  • Increasing a Linux partition once VM size increased in vSphere?

    - by dannymcc
    I have a Ubuntu 12.04 VM running on VMWares ESXi 5.1. The server (VM) itself has run out of space, the results of df -h are as follows: Filesystem Size Used Avail Use% Mounted on /dev/sda1 19G 17G 1.2G 94% / udev 490M 4.0K 490M 1% /dev tmpfs 200M 232K 199M 1% /run none 5.0M 0 5.0M 0% /run/lock none 498M 0 498M 0% /run/shm The original VM HDD size was just under 19GB which is I have now increased to 100GB within the vCenter GUI: Is there a simple way of doing this? The VM doesn't seem to acknowledge the increase at all.

    Read the article

  • Kill the Menu......

    - by Curdasss
    Downloaded and installed VM Player 3.0. two questions? 1.) Can I use Windows SMS to install the player on a users computer? If yes. Were can I find this information? 2.) Is there a hack of fix that allows me to kill/remove/hide the Player menus? I don't want the user to build new VM machines, just run the one want them to run. Not allowed to use Workstation or Ace to dist the vm Thanks

    Read the article

  • Is vSphere's Data Recover appliance 'production-ready'?

    - by Chopper3
    I have a smallish lab environment (16 x ESX4iU1 hosts and VC4U1) that I periodically want to backup. Normally in production we snap to secondary SAN boxes then have disk-based VTL backups via NetBackup which eventually migrate to off-site removable disks but this seems like an overkill for my own kit. I've spent a bit of time with vSphere's 'Data Recovery' appliance, it was easy enough to setup and I've not really ran into any issues with it but that doesn't mean I trust it fully. Have you had any experiences with it, positive or negative that would help me decide whether to trust it or pay Symantec for more licences? Thank you in advance.

    Read the article

  • What happens with the Guest OS's on ESXi in the event of a power failure?

    - by Jeremy Holovacs
    Many small businesses would prefer to let their server drop on power failure than to pay even $100 for a cheap UPS. It's often difficult to convince them of the value of something like that; it's why they like ESXi. It's free, they can save a lot of cash by putting a bunch of linux servers on one machine, and then I get paid. :) If the ESXi server experiences a power outage, it is set to come back on automatically when power is restored. What happens with the guest OS's? Ideally I would like them to all come online again as well, assuming they were on when power was lost, but I see no option for choosing this. I don't want to yank power to the system just to try it out, of course. I'm sure someone knows what happens by default, and perhaps how to make my system to work as I would wish.

    Read the article

  • Multiple VLANs in the same subnet

    - by A.J.
    Is it possible to have multiple VLANs in the same subnet, with the same gateway address (TMG)? I want to avoid having many Subnets (and vNIC's in TMG) just to isolate sets of a few hosts. IP: 10.0.0.1 (TMG server) VLAN:1 ~ 3 IP: 10.0.0.11 ~ 20 (Hosts group 1) VLAN:1 IP: 10.0.0.21 ~ 30 (Hosts group 2) VLAN:2 IP: 10.0.0.31 ~ 40 (Hosts group 3) VLAN:3 Note that I don't want them to connect to each other, so ARP/inter-vlan routing (within the subnet) is not required. The gateway is running in a VM within ESXi 5, I can pass the VLans to the VM using VGT or VLan Range, but I don't know how the OS/TMG should handle them.

    Read the article

  • Where's my memory?! Nginx + PHP-FPM front end webserver slows to a crawl...

    - by incredimike
    I'm not sure if I have a problem with a memory leak (as my hosting company suggests), or if we both need to read http://linuxatemyram.com. Maybe you clever people can help us out? This is a front-end webserver VM running essentially only nginx & php-fpm on RHEL 5.5. This server is powering Magento, a PHP eCommerce thinggy. The server is running in a shared environment, but we're changing that soon. Anyway.. after a reboot the server runs just fine, but within a day it will grind itself into nothingness. Pages will take literally 2 minutes to load, CPU spikes like crazy, etc.. The console is even sluggish when I SSH in. It's like my whole server is being brought to its knees. I've also been monitoring the DB server via top and tcpdumping incoming traffic. The DB stays idle for a good portion of that "slow" load time. When i start seeing queries coming from the front-end server, the page loads soon afterward. Here are some stats after me logging in during a slow-down, after restarting php-fpm: [mike@front01 ~]$ free -m total used free shared buffers cached Mem: 5963 5217 745 0 192 314 -/+ buffers/cache: 4711 1252 Swap: 4047 4 4042 [mike@front01 ~]$ top top - 11:38:55 up 2 days, 1:01, 3 users, load average: 0.06, 0.17, 0.21 Tasks: 131 total, 1 running, 130 sleeping, 0 stopped, 0 zombie Cpu0 : 0.0%us, 0.3%sy, 0.0%ni, 99.3%id, 0.3%wa, 0.0%hi, 0.0%si, 0.0%st Cpu1 : 0.3%us, 0.0%sy, 0.0%ni, 99.7%id, 0.0%wa, 0.0%hi, 0.0%si, 0.0%st Cpu2 : 0.0%us, 0.0%sy, 0.0%ni,100.0%id, 0.0%wa, 0.0%hi, 0.0%si, 0.0%st Cpu3 : 0.0%us, 0.0%sy, 0.0%ni,100.0%id, 0.0%wa, 0.0%hi, 0.0%si, 0.0%st Mem: 6106800k total, 5361288k used, 745512k free, 199960k buffers Swap: 4144728k total, 4976k used, 4139752k free, 328480k cached PID USER PR NI VIRT RES SHR S %CPU %MEM TIME+ COMMAND 31806 apache 15 0 601m 120m 37m S 0.0 2.0 0:22.23 php-fpm 31805 apache 15 0 549m 66m 31m S 0.0 1.1 0:14.54 php-fpm 31809 apache 16 0 547m 65m 32m S 0.0 1.1 0:12.84 php-fpm 32285 apache 15 0 546m 63m 33m S 0.0 1.1 0:09.22 php-fpm 32373 apache 15 0 546m 62m 32m S 0.0 1.1 0:09.66 php-fpm 31808 apache 16 0 543m 60m 35m S 0.0 1.0 0:18.93 php-fpm 31807 apache 16 0 533m 49m 30m S 0.0 0.8 0:08.93 php-fpm 32092 apache 15 0 535m 48m 27m S 0.0 0.8 0:06.67 php-fpm 4392 root 18 0 194m 10m 7184 S 0.0 0.2 0:06.96 cvd 4064 root 15 0 154m 8304 4220 S 0.0 0.1 3:55.57 snmpd 4394 root 15 0 119m 5660 2944 S 0.0 0.1 0:02.84 EvMgrC 31804 root 15 0 519m 5180 932 S 0.0 0.1 0:00.46 php-fpm 4138 ntp 15 0 23396 5032 3904 S 0.0 0.1 0:02.38 ntpd 643 nginx 15 0 95276 4408 1524 S 0.0 0.1 0:01.15 nginx 5131 root 16 0 90128 3340 2600 S 0.0 0.1 0:01.41 sshd 28467 root 15 0 90128 3340 2600 S 0.0 0.1 0:00.35 sshd 32602 root 16 0 90128 3332 2600 S 0.0 0.1 0:00.36 sshd 1614 root 16 0 90128 3308 2588 S 0.0 0.1 0:00.02 sshd 2817 root 5 -10 7216 3140 1724 S 0.0 0.1 0:03.80 iscsid 4161 root 15 0 66948 2340 800 S 0.0 0.0 0:10.35 sendmail 1617 nicole 17 0 53876 2000 1516 S 0.0 0.0 0:00.02 sftp-server ... Is there anything else I should be looking at, or any more information that might be useful? I'm just a developer, but the slowdowns on this system worry me and make it hard to do my work.. Help me out, ServerFault!

    Read the article

  • Checking partition alignment with PowerCLI

    - by Julian
    I'm trying to verify that the file system partitions within each of the servers I'm working on are aligned correctly. I've got the following script that when I've tried running will either claim that all virtual servers are aligned or not aligned based on which if statement I use (one is commented out): $myArr = @() $vms = get-vm | where {$_.PowerState -eq "PoweredOn" -and $_.Guest.OSFullName -match "Microsoft Windows*" } | sort name foreach($vm in $vms){ $wmi = get-wmiobject -class "win32_DiskPartition" -namespace "root\CIMV2" -ComputerName $vm foreach ($partition in $wmi){ $Details = "" | Select-Object VMName, Partition, Status #if (($partition.startingoffset % 65536) -isnot [decimal]){ if ($partition.startingoffSet -eq "65536"){ $Details.VMName = $partition.SystemName $Details.Partition = $partition.Name $Details.Status = "Partition aligned" } else{ $Details.VMName = $partition.SystemName $Details.Partition = $partition.Name $Details.Status = "Partition not aligned" } $myArr += $Details } } $myArr | Export-CSV -NoTypeInformation "C:\users\myself\Documents\Scripts\PartitionAlignment.csv" Would anyone know what is wrong with my code? I'm still learning about partitions so I'm not sure how I need to check the starting off-set number to verify alignment. EDIT: $myArr = @() $vms = get-vm | where {$_.PowerState -eq "PoweredOn" -and $_.Guest.OSFullName -match "Microsoft Windows*" } | sort name $wmi = get-wmiobject -class "win32_DiskPartition" -namespace "root\CIMV2" -ComputerName $vm #foreach ($_ In Get-WMIObject Win32_DiskPartition | Select Name, BlockSize, NumberOfBlocks, StartingOffSet, @{n='Alignment'; e={$_.StartingOffSet/$_.BlockSize}}) {$_} foreach ($wmi| Select Name, BlockSize, NumberOfBlocks, StartingOffSet, @{n='Alignment'; e={$_.StartingOffSet/$_.BlockSize}}) {$_}

    Read the article

  • Gathering buslogic SCSI hardware and virtual machine operating system

    - by Julian
    I'm trying to use Powershell to get SCSI hardware from several virtual servers and get the operating system of each specific server. I've managed to get the specific SCSI hardware that I want to find with my code, however I'm unable to figure out how to properly get the operating system of each of the servers. Also, I'm trying to send all the data that I find into a csv log file, however I'm unsure of how you can make a powershell script create multiple columns. Here is my code (almost works but something's wrong): $log = "C:\Users\me\Documents\Scripts\ScsiLog.csv" Get-VM | Foreach-Object { $vm = $_ Get-ScsiController -VM $vm | Where-Object { $_.Type -eq "VirtualBusLogic" } | Foreach-Object { get-VMGuest -VM $vm } | Foreach-Object{ Write-output $vm.Guest.VmName >> $log } } I don't receive any errors when I run this code however whenever I run it I'm only getting the name of the servers and not the OS. Also I'm not sure what I need to do to make the OS appear in a different column from the name of the server in the csv log that I'm creating. What do I need to change in my code to get the OS version of each virtual machine and output it in a different column in my csv log file? EDIT: Here's a more in depth look at things I've tried that have all failed: Get-VM | Foreach-Object { $vm = $_ $svm = Get-ScsiController -VM $vm | Where-Object { $_.Type -eq "VirtualBusLogic" } Foreach-Object {get-VMGuest -VM $svm } | Foreach-Object{Write-output $svm >> $log} } #Get-VM | Foreach-Object { # $vm = $_ # Get-ScsiController -VM $vm | Where-Object { $_.Type -eq "VirtualBusLogic"} #| write-host $vm # | Foreach-Object { # # #get-VMGuest -VM $_ | # #write-host $vm # #get-VMGuest -VM $vm } | Foreach-Object{ # #write-output $vm.VmName >> $log # #write-output $vm.guest.VmName, get-VmGuest -VM $vm >> $log NO GOOD # # Write-host $vm.Guest.VmName #+ get-vmGuest -vm $VM >> $log # # # } # } I'm not sure why get-VmGuest fails though. I'm getting the scsi hardware, filtering the hardware to only get buslogic, and then wanting to get the operating system of just the filtered VMs. I don't see where my code fails though.

    Read the article

  • Is it possible to connect machine to esxi Virtual Machine directly

    - by Mirage
    I have one server and i want to install VMs on that. Now i want to use one of VM as my main OS and i want that when i turn on second computer then that VM OS opens up. One way is to use remote desktop connection but for that i need to install OS on Second computer. Is there any way to directly link Second computer to VM on Server so that i don't have to install OS

    Read the article

  • Design Question

    - by dturner71
    Can I have two independent Connection servers attached to the same vCenter server? Here's my scenario. I'm setting up View 4 to provide desktops to two seperate Windows domains that are on different IP subnets seperated by a firewall. One cluster of physical servers, one vCenter server, linked clones. As I understand it View Connection server has to be a member of a Windows domain in order for quickprep to work. So the way to provide desktops to both Windows domains is to have a Connection server in each one right? Then open ports in the firewall so the Connection server from the other subnet can communicate with vCenter. Any reason why this won't work? Or is there a better way to accomplish it?

    Read the article

  • ESXi v5.5 is having random crashes

    - by Darkmage
    HW: Type: HP Proliant ML350 G5 RAM 22GB CPU 1 x Intel Xenon E5405 2.00GHz OP: ESXi 5.5 just updated from 5.1 to try and fix the crashes occurring on ESXi 5.1 on same hardware. I'm trying to find the error on why one of our servers is crashing, it has had two lock ups in 24 hours now. The internal error light on the front is blinking red, on the inside only "#5 and #6 page 76 manual" the "Processor 2" light "amber" and the "Power" light "green" is shining. in the logs the only errors i can see in the relevant time frame is in log under. Is this the reason? or is there anything else i can do to try and log/locate the error. from zcat syslog.6.gz | less 2014-05-26T11:55:47Z sfcbd[35064]: Error opening socket pair for getProviderContext: Too many open files 2014-05-26T11:55:47Z sfcbd[35064]: Failed to set recv timeout (30) for socket -1. Errno = 9 2014-05-26T11:55:47Z sfcbd[35064]: Failed to set timeout for local socket (e.g. provider) 2014-05-26T11:55:47Z sfcbd[35064]: spGetMsg receiving from -1 35064-9 Bad file descriptor 2014-05-26T11:55:47Z sfcbd[35064]: rcvMsg receiving from -1 35064-9 Bad file descriptor 2014-05-26T11:55:47Z sfcb-ProviderManager[34828]: SendMsg sending to 1 34828-9 Bad file descriptor 2014-05-26T11:55:47Z sfcb-ProviderManager[34828]: SendMsg sending to 1 34828-9 Bad file descriptor 2014-05-26T11:55:47Z sfcb-ProviderManager[34828]: SendMsg sending to 1 34828-9 Bad file descriptor 2014-05-26T11:55:47Z sfcbd[35064]: Error opening socket pair for getProviderContext: Too many open files 2014-05-26T11:55:47Z sfcbd[35064]: Failed to set recv timeout (30) for socket -1. Errno = 9 2014-05-26T11:55:47Z sfcbd[35064]: Failed to set timeout for local socket (e.g. provider) 2014-05-26T11:55:47Z sfcbd[35064]: spGetMsg receiving from -1 35064-9 Bad file descriptor 2014-05-26T11:55:47Z sfcbd[35064]: rcvMsg receiving from -1 35064-9 Bad file descriptor 2014-05-26T11:55:47Z sfcb-ProviderManager[34828]: SendMsg sending to 1 34828-9 Bad file descriptor 2014-05-26T11:55:47Z sfcb-ProviderManager[34828]: SendMsg sending to 1 34828-9 Bad file descriptor 2014-05-26T11:55:47Z sfcb-ProviderManager[34828]: SendMsg sending to 1 34828-9 Bad file descriptor 2014-05-26T11:55:53Z sfcb-ProviderManager[34828]: SendMsg sending to 1 34828-9 Bad file descriptor 2014-05-26T11:55:57Z sfcb-ProviderManager[34828]: SendMsg sending to 1 34828-9 Bad file descriptor 2014-05-26T11:56:01Z sfcb-ProviderManager[34828]: SendMsg sending to 1 34828-9 Bad file descriptor 2014-05-26T11:56:04Z sfcb-ProviderManager[34828]: SendMsg sending to 1 34828-9 Bad file descriptor 2014-05-26T11:56:15Z sfcb-ProviderManager[34828]: SendMsg sending to 1 34828-9 Bad file descriptor 2014-05-26T11:56:17Z sfcbd[35064]: Error opening socket pair for getProviderContext: Too many open files 2014-05-26T11:56:17Z sfcbd[35064]: Failed to set recv timeout (30) for socket -1. Errno = 9 2014-05-26T11:56:17Z sfcbd[35064]: Failed to set timeout for local socket (e.g. provider) 2014-05-26T11:56:17Z sfcbd[35064]: spGetMsg receiving from -1 35064-9 Bad file descriptor 2014-05-26T11:56:17Z sfcbd[35064]: rcvMsg receiving from -1 35064-9 Bad file descriptor 2014-05-26T11:56:17Z sfcb-ProviderManager[34828]: SendMsg sending to 1 34828-9 Bad file descriptor 2014-05-26T11:56:17Z sfcb-ProviderManager[34828]: SendMsg sending to 1 34828-9 Bad file descriptor 2014-05-26T11:56:17Z sfcb-ProviderManager[34828]: SendMsg sending to 1 34828-9 Bad file descriptor 2014-05-26T11:56:17Z sfcbd[35064]: Error opening socket pair for getProviderContext: Too many open files 2014-05-26T11:56:17Z sfcbd[35064]: Failed to set recv timeout (30) for socket -1. Errno = 9 2014-05-26T11:56:17Z sfcbd[35064]: Failed to set timeout for local socket (e.g. provider) 2014-05-26T11:56:17Z sfcbd[35064]: spGetMsg receiving from -1 35064-9 Bad file descriptor 2014-05-26T11:56:17Z sfcbd[35064]: rcvMsg receiving from -1 35064-9 Bad file descriptor 2014-05-26T11:56:17Z sfcb-ProviderManager[34828]: SendMsg sending to 1 34828-9 Bad file descriptor 2014-05-26T11:56:17Z sfcb-ProviderManager[34828]: SendMsg sending to 1 34828-9 Bad file descriptor 2014-05-26T11:56:17Z sfcb-ProviderManager[34828]: SendMsg sending to 1 34828-9 Bad file descriptor 2014-05-26T11:56:23Z sfcb-ProviderManager[34828]: SendMsg sending to 1 34828-9 Bad file descriptor 2014-05-26T11:56:27Z sfcb-ProviderManager[34828]: SendMsg sending to 1 34828-9 Bad file descriptor 2014-05-26T11:56:31Z sfcb-ProviderManager[34828]: SendMsg sending to 1 34828-9 Bad file descriptor 2014-05-26T11:56:34Z sfcb-ProviderManager[34828]: SendMsg sending to 1 34828-9 Bad file descriptor 2014-05-26T11:56:34Z sfcb-ProviderManager[34828]: SendMsg sending to 1 34828-9 Bad file descriptor 2014-05-26T11:56:34Z sfcb-ProviderManager[34828]: SendMsg sending to 1 34828-9 Bad file descriptor 2014-05-26T11:56:34Z sfcb-ProviderManager[34828]: SendMsg sending to 1 34828-9 Bad file descriptor 2014-05-26T11:56:34Z sfcb-ProviderManager[34828]: SendMsg sending to 1 34828-9 Bad file descriptor 2014-05-26T11:56:44Z sfcb-ProviderManager[34828]: SendMsg sending to 1 34828-9 Bad file descriptor 2014-05-26T11:56:44Z sfcb-ProviderManager[34828]: SendMsg sending to 1 34828-9 Bad file descriptor 2014-05-26T11:56:44Z sfcb-ProviderManager[34828]: SendMsg sending to 1 34828-9 Bad file descriptor 2014-05-26T11:56:44Z sfcb-ProviderManager[34828]: SendMsg sending to 1 34828-9 Bad file descriptor 2014-05-26T11:56:46Z sfcb-ProviderManager[34828]: SendMsg sending to 1 34828-9 Bad file descriptor 2014-05-26T11:56:48Z sfcbd[35064]: Error opening socket pair for getProviderContext: Too many open files -- manual

    Read the article