  • Issue with VMWare vSphere and NFS: re occurring apd state

    - by Bastian N.
    I am experiencing issues with VMWare vSphere 5.1 and NFS storage on 2 different setups, which result in an "All Path Down" state for the NFS shares. This first happened once or twice a day, but lately it occurs much more frequent, as specially when Acronis Backup jobs are running. Setup 1 (Production): 2 ESXi 5.1 hosts (Essentials Plus) + OpenFiler with NFS as storage Setup 2 (Lab): 1 ESXi 5.1 host + Ubuntu 12.04 LTS with NFS as storage Here is an example from the vmkernel.log: 2013-05-28T08:07:33.479Z cpu0:2054)StorageApdHandler: 248: APD Timer started for ident [987c2dd0-02658e1e] 2013-05-28T08:07:33.479Z cpu0:2054)StorageApdHandler: 395: Device or filesystem with identifier [987c2dd0-02658e1e] has entered the All Paths Down state. 2013-05-28T08:07:33.479Z cpu0:2054)StorageApdHandler: 846: APD Start for ident [987c2dd0-02658e1e]! 2013-05-28T08:07:37.485Z cpu0:2052)NFSLock: 610: Stop accessing fd 0x410007e4cf28 3 2013-05-28T08:07:37.485Z cpu0:2052)NFSLock: 610: Stop accessing fd 0x410007e4d0e8 3 2013-05-28T08:07:41.280Z cpu1:2049)StorageApdHandler: 277: APD Timer killed for ident [987c2dd0-02658e1e] 2013-05-28T08:07:41.280Z cpu1:2049)StorageApdHandler: 402: Device or filesystem with identifier [987c2dd0-02658e1e] has exited the All Paths Down state. 2013-05-28T08:07:41.281Z cpu1:2049)StorageApdHandler: 902: APD Exit for ident [987c2dd0-02658e1e]! 2013-05-28T08:07:52.300Z cpu1:3679)NFSLock: 570: Start accessing fd 0x410007e4d0e8 again 2013-05-28T08:07:52.300Z cpu1:3679)NFSLock: 570: Start accessing fd 0x410007e4cf28 again As long as the issue occurred once or twice a day it really wasn't a problem, but now this issue has impact on the VMs. The VMs get slow or even hang, resulting in a reset through vCenter in the production environment. I searched the web extensively and asked in forums, but till now nobody was able to help me. Based on blog posts and VMWare KB articles I tried the following NFS settings: Net.TcpipHeapSize = 32 Net.TcpipHeapMax = 128 NFS.HartbeatFrequency = 12 NFS.HartbeatMaxFailures = 10 NFS.HartbeatTimeout = 5 NFS.MaxQueueDepth = 64 Instead of NFS.MaxQueueDepth = 64 I already tried other settings like NFS.MaxQueueDepth = 32 or even NFS.MaxQueueDepth = 1. Unfortunately without any luck. It would be great if someone could help me on this issue. It is really annoying. Thanks in advance for all the help. [UPDATE] As I explained in the comment below, here is the network setup: On the production setup the NFS traffic is bound to a separate VLAN with ID 20. I am using a HP 1810 24 Port Switch. The OpenFiler system is connected to the VLAN with 4 Intel GbE NICs with dynamic LACP. The ESXis both have 4 Intel GbE NICs using 2 static LACP trunks containing 2 NICs each. One pair is connected to the regular LAN and the other one to the VLAN 20. And here is a screenshot of the vSwitch: Switch configuration: Port configuration: On the lab setup its a single Intel NIC on each side without VLAN, but with different IP subnet.

    Read the article

  • Packet dropped even when firewall is turned off in windows server 2008

    - by LightX
    We have a windows 2008 server and lately we have started seeing a lot of 5152 Events logged in the server (Windows Filtering Platform blocked a packet). We have an inbound rule configured to allow connections to the port which was working fine earlier. I'm not sure what changed lately. But this doesn't make any sense. The packet is dropped even when windows firewall is disabled. What am I missing?

    Read the article

  • Why does a wired network slow down with user increase?

    - by Ed Briscoe
    If you had a wired network, 20 PCs hooked up to a 100 Mbit/sec switch (same onboard ethernet port speed) and you were just sending some test data round. What is the technical explanation as to why 20 machines sending test data around this network to each other is slower than one to one? I mean I know a busy network means it's slower but I'm really trying to understand some more technical details. Thanks for any help

    Read the article

  • How to avoid Windows Genuine Advantage for an XP update?

    - by hlovdal
    I am about to apply updates to a windows xp installation I have not booted in a couple of years. When going to update.microsoft.com, it forced me first to accept an activex installation and now it wants me to install wga: Windows Update To use this latest version of Windows Update, you will need to upgrade some of its components. This version provides you with the following enhancements to our service: <... useless list of "advantages" ... Details Windows Genuine Advantage Validation Tool (KB892130) 1.1 MB , less than 1 minute The Windows Genuine Advantage Validation Tool enables you to verify that your copy of Microsoft Windows is genuine. The tool validates your Windows installation by checking Windows Product Identification and Product Activation status. Update for Windows XP (KB898461) 477 KB , less than 1 minute This update installs a permanent copy of Package Installer for Windows to enable software updates to have a significantly smaller download size. The Package Installer facilitates the install of software updates for Microsoft Windows operating systems and other Microsoft products. After you install this update, you may have to restart your system. Total: 1.5 MB , less than 1 minute I have heard nothing but bad things about wga, and I absolutely do not want it installed on my system (this answer seems to give some options). Searching for "windows xp" at microsoft's web pages brought up this page which says Windows XP Service Pack 3 Network Installation Package for IT Professionals and Developers Brief Description This installation package is intended for IT professionals and developers downloading and installing on multiple computers on a network. If you're updating just one computer, please visit Windows Update at http://update.microsoft.com . ... File Name: WindowsXP-KB936929-SP3-x86-ENU.exe I am currently downloading this file. Will installing this bring my installation up to date with security updates? What about later updates whenever a new problem is discovered, how can i update without using wga?

    Read the article

  • Unable to connect Third monitor to my workstation

    - by Prashant
    I have Dell Optiplex 960 with ATI Radeon HD 3470 graphics card, which allowed me to hook two monitors to it. However there is still VGA port on mother board is unused. I tried plugging another monitor, surprisingly my third monitor doesn't directed. Can any one give me a hint how to fix this problem?

    Read the article

  • Bladecenter-E Power Module fault

    - by Lihnjo
    We have problem on IBM Bladecenter-E Critical Events Power module 2 is off. DC fault. Power module 4 is off. DC fault. Warnings and System Events Insufficient chassis power to support redundancy What is the best solution for this problem? Thanks AMM Service Data Help SPAPP Capture Available 10/13/2010 17:03:47 1090347 bytes Time: 11/19/2012 11:02:31 UUID: 42E1 5D2F D7BF 41A6 A4A2 48D1 3FB7 0540 MAC Address xx:xx:xx:xx:xx:xx MM Information Name: nnnnn Contact: aaa, bbb, ccc, England Location: [email protected] IP address: 111.222.333.444 Date Time Information GMT offset: +1:00 - Central Europe Time (Western Europe, Algeria, Nigeria, Angola) Adjust for DST: Yes NTP: Enabled NTP Hostname/IP: 111.222.333.444 System Health: Critical System Status Summary One or more monitored parameters are abnormal. Critical Events Power module 2 is off. DC fault. Power module 4 is off. DC fault. Warnings and System Events Insufficient chassis power to support redundancy CHASSIS (BladeCenter-E) in CHASSIS slot: 01 TopoPath is "CHASSIS[1]". Description : BladeCenter-E Width : 1 Sub Type : BladeCenter (BC) Power Mode : 220 v KVM Owner : CHASSIS[1]/BLADE[9] MT Owner : CHASSIS[1]/MGMT_MOD[1] Component Type : CHASSIS Inventory: VPD ID: 336 (decimal) POS ID EXT: 0 (decimal) POS ID: 8 (decimal) Machine Type/Model: 86773RG Machine Serial Number: 99ZL816 Part Number: 39R8561 FRU Number: 39R8563 FRU Serial Number: YK109174W1HV Manufacturer ID: IBM Hardware Revision: 3 (decimal) Manufacture Date: 18 (wk), 07 (yr) UUID: 42E1 5D2F D7BF 41A6 A4A2 48D1 3FB7 0540 (hex) Type Code: 97 (decimal) Sub-type Code: 0 (decimal) IANA Num: 336 (decimal) Product ID: 8 (decimal) Manufacturer Sub ID: FOXC Enviroment data: -------------- Type: : POWER_USAGE Unit: : WATTS Reading: : 0xa Sensor Label: : Midplane Sensor ID: : 0x0 MGMT MOD (Advanced Management Module) in MGMT_MOD slot: 01 TopoPath is "CHASSIS[1]/MGMT_MOD[1]". Description : Advanced Management Module Name : kant Width : 1 Component Role : Primary Component Type : MGMT MOD Insert Time : 28050132 Inventory: VPD ID: 288 (decimal) POS ID EXT: 0 (decimal) POS ID: 4 (decimal) Part Number: 39Y9659 FRU Number: 39Y9661 FRU Serial Number: YK11836CE2RC Manufacturer ID: IBM Hardware Revision: 4 (decimal) Manufacture Date: 50 (wk), 06 (yr) UUID: 1D95 9937 8CA5 11DB 9499 0014 5EDF 1C98 (hex) Type Code: 81 (decimal) Sub-type Code: 1 (decimal) IANA Num: 20301 (decimal) Product ID: 65 (decimal) Manufacturer Sub ID: ASUS Firmware data: Type : AMM firmware Build ID : BPET50P File Name : CNETCMUS.PKT Release Date : 03/26/2010 Release Level : 50 Revision - Major: 80 Port info: ======================================================== Topology Path ID : 1 Label : External Phy Orientation : EXTERNAL Port Number : 1 Type : MGT Physical Meidum : Copper Number of Link Intferfaces : 1 ------------------------------------ Link Ifc ID Number : 1 Link Ifc Transport Protocol : ENET Link Ifc Addr Type : MAC Link Ifc Burned-in Addr : xx:xx:xx:xx:xx:xx Link Ifc Admin Addr : 00:00:00:00:00:00 Link Ifc Addr in use : xx:xx:xx:xx:xx:xx ---------------------------------------------------------- Configuration behaviors: Save Only Enviroment data: -------------- Type: : TEMPERATURE Unit: : DEGREES_C Reading: : 38.00 Sensor Label: : MM Ambient Sensor ID: : 0x0 -------------- Type: : VOLTAGE Unit: : VOLTS Reading: : +4.81 Sensor Label: : +5V Sensor ID: : 0x1b -------------- Type: : VOLTAGE Unit: : VOLTS Reading: : +3.26 Sensor Label: : +3.3V Sensor ID: : 0x19 -------------- Type: : VOLTAGE Unit: : VOLTS Reading: : +11.97 Sensor Label: : +12V Sensor ID: : 0x16 -------------- Type: : VOLTAGE Unit: : VOLTS Reading: : -4.88 Sensor Label: : -5V Sensor ID: : 0x1e -------------- Type: : VOLTAGE Unit: : VOLTS Reading: : +2.47 Sensor Label: : +2.5V Sensor ID: : 0x18 -------------- Type: : VOLTAGE Unit: : VOLTS Reading: : +1.76 Sensor Label: : +1.8V Sensor ID: : 0x15 -------------- Type: : POWER_USAGE Unit: : WATTS Reading: : 0x19 Sensor Label: : kant Sensor ID: : 0x0

    Read the article

  • Spanning-tree setup with incompatible switches

    - by wfaulk
    I have a set of eight HP ProCurve 2910al-48G Ethernet switches at my datacenter that are set up in a star topology with no physical loops. I want to partially mesh the switches for redundancy and manage the loops with a spanning-tree protocol. However, our connection to the datacenter is provided by two uplinks, each to a Cisco 3750. The datacenter's switches are handling the redundant connection using PVST spanning-tree, which is a Cisco-proprietary spanning-tree implementation that my HP switches do not support. It appears that my switches are not participating in the datacenter's spanning-tree domain, but are blindly passing the BPDUs between the two switchports on my side, which enables the datacenter's switches to recognize the loop and put one of the uplinks into the Blocking state. This is somewhat supposition, but I can confirm that, while my switches say that both of the uplink ports are forwarding, only one is passing any real quantity of data. (I am assuming that I cannot get the datacenter to move away from PVST. I don't know that I'd want them to make that significant of a change anyway.) The datacenter has also sent me this output from their switches (which I have expurgated of any identifiable info): 3750G-1#sh spanning-tree vlan nnn VLAN0nnn Spanning tree enabled protocol ieee Root ID Priority 10 Address 00d0.0114.xxxx Cost 4 Port 5 (GigabitEthernet1/0/5) Hello Time 2 sec Max Age 20 sec Forward Delay 15 sec Bridge ID Priority 32mmm (priority 32768 sys-id-ext nnn) Address 0018.73d3.yyyy Hello Time 2 sec Max Age 20 sec Forward Delay 15 sec Aging Time 300 sec Interface Role Sts Cost Prio.Nbr Type ------------------- ---- --- --------- -------- -------------------------------- Gi1/0/5 Root FWD 4 128.5 P2p Gi1/0/6 Altn BLK 4 128.6 P2p Gi1/0/8 Altn BLK 4 128.8 P2p and: 3750G-2#sh spanning-tree vlan nnn VLAN0nnn Spanning tree enabled protocol ieee Root ID Priority 10 Address 00d0.0114.xxxx Cost 4 Port 6 (GigabitEthernet1/0/6) Hello Time 2 sec Max Age 20 sec Forward Delay 15 sec Bridge ID Priority 32mmm (priority 32768 sys-id-ext nnn) Address 000f.f71e.zzzz Hello Time 2 sec Max Age 20 sec Forward Delay 15 sec Aging Time 300 sec Interface Role Sts Cost Prio.Nbr Type ------------------- ---- --- --------- -------- -------------------------------- Gi1/0/1 Desg FWD 4 128.1 P2p Gi1/0/5 Altn BLK 4 128.5 P2p Gi1/0/6 Root FWD 4 128.6 P2p Gi1/0/8 Desg FWD 4 128.8 P2p The uplinks to my switches are on Gi1/0/8 on both of their switches. The uplink ports are configured with a single tagged VLAN. I am also using a number of other tagged VLANs in my switch infrastructure. And, to be clear, I am passing the tagged VLAN I'm receiving from the datacenter to other ports on other switches in my infrastructure. My question is: how do I configure my switches so that I can use a spanning tree protocol inside my switch infrastructure without breaking the datacenter's spanning tree that I cannot participate in?

    Read the article

  • How to prevent nginx from locking files on mounted samba partition in Centos 6

    - by Bruce Kirkpatrick
    I'm using nginx 1.3.8 inside a centos 6.3 virtualbox 4.2.4 virtual machine. The system is running the latest software available via yum update. The host OS is windows 7. The site files nginx is serving are on mounted samba partition, which is a folder on the host Windows system. I.e., inside linux, nginx paths are referring to /home/vhosts and this is mounted from D:\vhosts\ on windows. The samba partition is mounted as root with 777 privileges. /etc/fstab looks like this, but with real ip, username, password: //hostip/vhosts /home/vhosts cifs username=username,password=SECRETPASSWORD,uid=root,gid=root,file_mode=0777,dir_mode=0777,rw,_netdev 0 0 I.e. linux/nginx reads from the windows share, and not the opposite. in /etc/samba/smb.conf, I have tried to disable all samba locking features, but it seems to have no effect even after rebooting the virtual machine. locking=no share modes=no oplocks = no level2 oplocks = no kernel oplocks =no I'm receiving "Access is denied" errors in Windows or linux when attempting to overwrite the javascript file in windows that has been accessed at least once with nginx. If I run "service nginx reload", the lock is removed and I'm able to save the file. That's why I think it is nginx causing the lock. The same problem occurs with directories. However, that may be a different issue not related to the use of samba. I'm using samba so that I can manage the source code outside of the virtual machine. Also note that after I run "service nginx reload", the file I'm editing is actually automatically deleted from the windows host. SOLVED: I just reviewed my nginx.conf file. It appears the "open_file_cache" feature is what is causing the lock and deleted files. When I set this option to open_file_cache off;, My problem is resolved. I will repost as the answer when it allows me to do so.

    Read the article

  • Memcached Debuging/Server Logs Monitor the Memcached Servers?

    - by user1179459
    I have chat engine which is based on the Memcached variables, putting them into arrays and reading them in other end via jquery, which works fine 95% of the times, however when the server load is high memcached (presume its the memcached) the crash and browser gets stucks up. I dont think its jquery issue since this only happens when the server load is very high. I need a way to monitor the memcached servers or somehow write a log file into where the fails/errors comes in... Any idea on how i can do this ? or any idea why memcached servers fails ? I run the memcached as follows $GLOBALS['MemCached'] = FALSE; $GLOBALS['MemCached'] = new Memcache; $GLOBALS['MemCached']->pconnect('localhost', 11211); My memcached config is as follows #! /bin/sh # # chkconfig: - 55 45 # description: The memcached daemon is a network memory cache service. # processname: memcached # config: /etc/sysconfig/memcached # pidfile: /var/run/memcached/memcached.pid # Standard LSB functions #. /lib/lsb/init-functions # Source function library. . /etc/init.d/functions PORT=11211 USER=memcached MAXCONN=1024 CACHESIZE=128 OPTIONS="" if [ -f /etc/sysconfig/memcached ];then . /etc/sysconfig/memcached fi # Check that networking is up. . /etc/sysconfig/network if [ "$NETWORKING" = "no" ] then exit 0 fi RETVAL=0 prog="memcached" pidfile=${PIDFILE-/var/run/memcached/memcached.pid} lockfile=${LOCKFILE-/var/lock/subsys/memcached} start () { echo -n $"Starting $prog: " # Ensure that /var/run/memcached has proper permissions if [ "`stat -c %U /var/run/memcached`" != "$USER" ]; then chown $USER /var/run/memcached fi daemon --pidfile ${pidfile} memcached -d -p $PORT -u $USER -m $CACHESIZE -c $MAXCONN -P ${pidfile} $OPTIONS RETVAL=$? echo [ $RETVAL -eq 0 ] && touch ${lockfile} } stop () { echo -n $"Stopping $prog: " killproc -p ${pidfile} /usr/bin/memcached RETVAL=$? echo if [ $RETVAL -eq 0 ] ; then rm -f ${lockfile} ${pidfile} fi } restart () { stop start } # See how we were called. case "$1" in start) start ;; stop) stop ;; status) status -p ${pidfile} memcached RETVAL=$? ;; restart|reload|force-reload) restart ;; condrestart|try-restart) [ -f ${lockfile} ] && restart || : ;; *) echo $"Usage: $0 {start|stop|status|restart|reload|force-reload|condrestart|try-restart}" RETVAL=2 ;; esac exit $RETVAL

    Read the article

  • Recommendation for Document Management Solution

    - by BillN
    We've just been informed by our software vendor that the custom document management system they'd written is no longer in development, and will not be supported in the future. So we are looking at new document management systems. Requirements: Multiple input vectors, we receive documents via e-mail, fax, scanning, and from the originating application Ability to Redact or obscure data. Customers may fax an order with CC data, we want to attach the image of the order form with the order record, but the CC data needs to be protected. Same with Tax IDs. Certain users should be able to see the redacted data, but access should be logged. Version control on documents. We'd like Product Development and Marketing to be able to track various versions of documents like Packaging Designs, but ensure that users have the latest approved version. AD integration, my users don't need another password. Ability to integrate to other apps. Our current system, offers function keys in the order-entry system, that will spawn the viewer application, and open the correct document. Mass import facility, we have a half a terabyte of existing documents in the old system that we would like to import. Retention Policy. I'd like a way to have the system comply with the corporate retention policy, so that when a document of a certain type reaches a certain age, it gets deleted, or atleast marked for manual deletion. We are a Windows Server and HP-UX shop. Does anybody have any experience with Document Management systems that they would like to share? Thanks.

    Read the article

  • two Ubuntu 12.04, 1x Netgear router

    - by RussellHarrower
    Ok, so I have 192.168.x.14 with port 80 open and I have set the netgear router to point there then I have 192.168.x.12 with apache running but when I try to connect using chrome to the website hosted on .12 it cant find it, how do I set up .14 to also check .12 /nagios is running on .12 while /munin is running on .14 Thank you for helping I know about Squid, but I don't know what to do? Do I use that or something else.

    Read the article

  • Simple way to make wired internet wireless without router

    - by Anriëtte Combrink
    Hi there Is there any device which you can plug into an Ethernet port and then have it broadcast the internet connection it receives through Ethernet wirelessly with a set password (maybe a serial number on device itself)? The problem is, I have a Wi-fi capable device, an iPhone and I want to use the wired internet connection in a hotel room, but the iPhone needs a Wi-fi signal. How can I accomplish this with a rather simplistic device. // EDIT: Can this be achieved with an Apple Airport Express?

    Read the article

  • Samba between Ubuntu server 10.10 and Windows Vista, Windows 7

    - by chepukha
    Hi all, I have a linux box running Linux server ubuntu 10.10. I have installed Samba on this linux box and want to share files with my laptops which run Windows Vista home and Windows 7 home. I have been struggling with the setup for almost a month but couldn't get it right. If I try to access share folder from Windows Vista, I get message "Windows cannot access \\server_ip_address". Error code: 0x80070035. The network path was not found. If I access from Windows 7, then after entering password to login I can see the list of share folders on Linux box. But if I click on a share folder, I get the same error message as above. Tail /var/log/samba/log.windows7-pc I got the following message: [2011/03/16 00:17:41.427238, 0] smbd/service.c:988(make_connection_snum) canonicalize_connect_path failed for service sharemedia, path /root/sharemedia Here is my setting in smb.conf [global] share modes = yes netbios name = Samba workgroup = WORKGROUP wins support = yes encrypt passwords = true [sharemedia] comment = Tesing sharing using Samba path=/root/sharemedia/ public = yes valid users = samba_usr_name ; make sure all files are sensible permissions create mask = 0660 force create mask = 0660 directory mask = 2770 force directory mask = 2770 directory security mask = 0000 ; Normal share parameters read only = no browseable = yes writable = yes guest ok = no

    Read the article

  • Creating Windows 8.1 system image error

    - by Random
    I'm experiencing "not enough space" error when trying to create system image to a USB hard drive: Detailed error: ERROR - A Volume Shadow Copy Service operation error has occurred: (0x8004231f) Insufficient storage available to create either the shadow copy storage file or other shadow copy data. Blah, blah... There is not enough disk space to create the volume shadow copy on the storage location. Make sure that, for all volumes to be backup up, the minimum required disk space for shadow copy creation is available. This applies to both the backup storage destination and volumes included in the backup. Minimum requirement: For volumes less than 500 megabytes, the minimum is 50 megabytes of free space. For volumes more than 500 megabytes, the minimum is 320 megabytes of free space. Recommended: At least 1 gigabyte of free disk space on each volume if volume size is more than 1 gigabyte. ERROR - A Volume Shadow Copy Service operation error has occurred: (0x8004231f) Insufficient storage available to create either the shadow copy storage file or other shadow copy data. I'd tried both - PowerShell wbAdmin start backup -backupTarget:E: -include:C: -allCritical -quiet and via Control Panel - File History button Clearly both EFI and Windows Recovery Environment partitions don't meet requirements coming from System Image tool (pic below) On top of that all system partitions are now shown as 100% free in Disk Management, it's disturbing but far from the actual state. My question is - hot to create System Image in Windows 8.1?

    Read the article

  • Fixing corrupt files or corrupt file table on a USB drive?

    - by Kelsey
    I was doing a virus scan on an external USB drive while copying data over to it. While AVG was scanning my system got locked up I think due to the USB drive running out of space and it required a reboot. Since that time all data on the external drive is no longer accessible. I can see all the files in the root and directories but I cannot browse into any of them as Windows 7 gives an error stating they are corrupt. I think the file table or whatever it uses to store the index of what exists on the drive has been corrupted since it still shows the the drive as being almost full but everything I do a properties check on says it is 0 bytes. Does anyone know how to 'unlock' or recover this data? Is there a way to rebuild the file table somehow? Luckily I can recover this data from other sources as a last resort but I would like to fix this if possible. Any help would be appreciated. Thanks.

    Read the article

  • What is the best way to keep a VGA cable plugged into a laptop

    - by Ryan B
    I am looking for the best way to keep a VGA cable plugged into a laptop for an extended period of time. The laptop doesn't have the female end threads like you may see on a video card. Between the VGA port location and my hand size, I knock the cable out often. I am working on getting a docking station, but not sure when it would be ordered (work-related). I found an adapter, but not sure if it will work. Thanks

    Read the article

  • ssh - no route to host

    - by cupakob
    I have 3 machines (A, B and C) behind WLAN Router. From B i can make ssh to A and from A to B also. Ssh between C and A is also working (both destination, C-A and A-C). But when i try to connect B to C or C to B i get always ssh: connect to host <HOST> port 22: No route to host What can be the reason for this error?

    Read the article

  • Windows Live Mail and Palm Pre

    - by itprofessionalsgroup
    Has anyone had any luck getting Windows Live mail to sync with a Palm Pre with WebOS 1.1? I have tried the manual setup options setting up the pop3 incoming server on port 995 with SSL encryption and the smtp out going server on both ports 25 and 587 with TTL encryption. It acts like it is connected, but it just keeps wanting to refresh and never shows anything in the inbox.

    Read the article

  • Hyperic HQ- Monitor process statistics for 50+ processes on Linux machine

    - by Chris
    Is there an easy way to get metrics on all processes that start with the letters XYZ? I have about 80 processes that I have to monitor individually that all start with the prefix XYZ. I have created a query using the sigar shell: ps State.Name.sw=XYZ, which will give me a list of the processes that I want. What I need to do is define this list of processes through said query and collect and track statistics from the Process service: http://support.hyperic.com/display/hypcomm/Process+service What I need is 3 or 4 key statistics for each of the XYZ processes defined by my query to show up as graphs in the web front end. Note: Hyperic HQ server is installed on a windows machine and I'm monitoring a Linux box via an agent. Thanks, Chris Edit: Here is my try at a plugin that may give me what I want, but it's not being inventoried/detected by the Hyperic web UI. Simply pointing me to one of Hyperic's tutorials won't do. Thanks. <!DOCTYPE plugin [ <!ENTITY process-metrics SYSTEM "/pdk/plugins/process-metrics.xml">]> <plugin> <server name="ABCStats"> <config> <option name="process.query" description="Process Query" default="State.Name.sw=XYZ"/> </config> <metric name="Availability" alias="Availability" template="sigar:Type=ProcState,Arg=%process.query%:State" category="AVAILABILITY" indicator="true" units="percentage" collectionType="dynamic"/> &process-metrics; <plugin type="autoinventory"/> <plugin type="measurement" class="org.hyperic.hq.product.MeasurementPlugin"/> </server> </plugin>

    Read the article

  • Upgrading memory on an IBM Power 710 Express (8231-E2B)

    - by cairnz
    We have a Power 710 Express server that was loaded with 4x4 GB memory on a single riser card. I have replaced the 4 chips with 4x8GB and put in another riser card and loaded it with 4x8GB more for a total of 64GB memory. The firmware is AL730_078. When i power it on, the service processor boots up and i can access the ASMi. From here I can look at "Memory Serial Presence Data" and see that the system in some way detects 8x8 GB. However when i look at Hardware Deconfiguration and specifically Memory Deconfiguration, it is still listed with old values, 16384MB, and claims there are 4x4 chips in the C17 riser. How do i proceed to make the server recognize properly the amount of memory installed? I get a FSPSP04 and B181B50F progress code on booting because (i think) it hasn't been told the memory has changed. It then does not proceed to booting the operating system (VIOS) when turned on. Are there any steps I have overlooked here? Can I do some commands, either on the service processor, or otherwise, to tell the system to configure with the proper amount of memory? PS: This is a stand alone server, not configured with HMC or SDMC.

    Read the article

  • very slow bridge detection

    - by deddihp
    hello everyone, I have setup some bridge interface with 4 ethernet port. My problem is, when they detect some network topology change, the bridge really need a lot of time to have done it. Is there any solution, so the bridge can detect topology change faster ? thanks.

    Read the article