Search Results

Search found 8876 results on 356 pages for 'hardware raid'.

Page 65/356 | < Previous Page | 61 62 63 64 65 66 67 68 69 70 71 72  | Next Page >

  • My computer is broken after recent update attempt to 14.04

    - by user317550
    So it all started on a day much like today, because it is today but that's not the point, when I got a notification telling me I haven't upgraded to 14.04. Not due to lack of trying, however. It offered to upgrade me itself. Now keep in mind, I've tried very hard to upgrade my is from 12.04 to 14.04. Many times, I believe, due to tinkering where there shouldn't be tinkering, my BIOS are messed up. So upgrading is essentially impossible, but I wasn't about to stop it from updating for me, thinking it didn't have too much to do with BIOS as it doesn't reboot until after. So I let it go about its business and some time later I look back at it, and my unity sidebar is gone, and anytime there's text on screen it shows as those box things. The real bottom line is that I want to know my options. All of them. I would love to be able to keep the stuff on my hard drive so a hard drive swap may be an option if you guys say that would work. I just need my computer back. Let me know if I left anything out. Peace! B^)

    Read the article

  • Ubuntu 12.10 Jerky mouse movments

    - by Bar Hofesh
    As the Title indicates I have some problem with delicate movement of the mouse in Ubuntu 12.10 fresh installation. The jerkiness is shown more at small and slow movements when the mouse will move a 2 millimeters to any random positions every 5 centimeters of movements. my mouse is a Microsoft Sidewinder Gaming mouse. is there any driver I can use to fix it or any configuration? this is happening both in unity or inside games and programs.

    Read the article

  • What is optimal hardware configuration for heavy load LAMP application

    - by Piotr Kochanski
    I need to run Linux-Apache-PHP-MySQL application (Moodle e-learning platform) for a large number of concurrent users - I am aiming 5000 users. By concurrent I mean that 5000 people should be able to work with the application at the same time. "Work" means not only do database reads but writes as well. The application is not very typical, since it is doing a lot of inserts/updates on the database, so caching techniques are not helping to much. We are using InnoDB storage engine. In addition application is not written with performance in mind. For instance one Apache thread usually occupies about 30-50 MB of RAM. I would be greatful for information what hardware is needed to build scalable configuration that is able to handle this kind of load. We are using right now two HP DLG 380 with two 4 core processors which are able to handle much lower load (typically 300-500 concurrent users). Is it reasonable to invest in this kind of boxes and build cluster using them or is it better to go with some more high-end hardware? I am particularly curious how many and how powerful servers are needed (number of processors/cores, size of RAM) what network equipment should be used (what kind of switches, network cards) any other hardware, like particular disc storage solutions, etc, that are needed Another thing is how to put together everything, that is what is the most optimal architecture. Clustering with MySQL is rather hard (people are complaining about MySQL Cluster, even here on Stackoverflow).

    Read the article

  • Best motherboard power supply combo for backblaze server

    - by jin14
    Building a backblaze server as described in this article. http://blog.backblaze.com/ So 45 hard drives in one box. I'm making it a MSDPM 2010 server so I actually don't even need raid cards in there as MSDPM will figure out how to use all of the hard drives on it's own. So need to know what motherboard, CPU, power supply I should get. Primary hard drive : SSD 128GB Storage : 45 1.5GB sata drives OS : windows 2008 Backup software : Microsoft System center Data protection server 2010 Need to know Which mother board to buy which will support 45 SATA hard drives. Don't need a raid card. Which power supply can power all 45 hard drives, 1 ssd drive, motherboard. Best set of equipment that meets my needs wins

    Read the article

  • Upgrading PS1 Light Gun [on hold]

    - by Nathan Taylor
    Is There any possible way to upgrade the retro G-con Light Gun for PS1 to allow it to interact with HD TV's? I am aware that they were Designed purely for Tube TV's but I would be happy to know of any hardware that would maybe convert the light to hit the Pixels on an LCD TV. If not is there any other Light gun that would work on PS1 games but has the newer light gun hardware that can interact with a higher Pixel LCD TV?

    Read the article

  • average temperature of CPU

    - by lego 69
    I downloaded the program named speedFan(for measuring the temperature of the hardware), and I have parameters like these GPU: 60C HDO: 38C Temp1: 50C Core 0: 44C Core 1: 44C Core: 59C Ambient: 0C I know that it shows me temperature of the different parts of my hardware, but I have no idea which ones, can You please explain it and also, is it something wrong with my laptop (because temperature of GPU is 60C) thanks in advance

    Read the article

  • New harddrives failing within weeks.

    - by Jason Kealey
    I've experienced 8 hard disk failures in 3 months and have tried many things to solve the issue permanently but I have failed. I would like to know if you have any advice for me. System was running Win XP on an Asus P5W-DH Deluxe. I have setup a RAID-1 array. I started out with 2 x 500 GB 7200RPM Western Digital drives. One died. I took it out to RMA it. On the same day, the router was fried. Assumed a power surge occurred; connected an older UPS to protect the system. Once I got my hands on an identical disk, I installed it. The RAID array was rebuilt. A few days later, the other one died. Assumed the rebuild caused it to fail. Took it out for RMA. Before the other one arrived, the remaining one died. I then discovered I could re-enable them using the Intel Matrix Storage Manager. I re-enabled both and the system seemed fine for a week, until both died again. I got two new 1.5 TB 7200RPM Seagate drives and re-installed Windows 7. Also replaced the UPS and power supply. They both died again. The voltage on the plug is stable between 120 and 122V as per the UPS. None of the other devices have had any problems (monitors, etc.). At this point, I see two options: a) electrical issue in the house that was, for some reason, not blocked by the UPS. b) something else inside the system causing surges? motherboard? onboard raid controller? Failures happen fairly quickly, between 2 and 14 days after I fix the previous issue. I just gotten a new computer (Core i7) to replace it. If it is stable, I can determine that b) was the problem. If it fries its hard drive again, I can determine that it is an electrical issue in the house. Do you have any other thoughts? Any tools I can run on the drives that failed to get more information about the original SMART event history?

    Read the article

  • Finding out why Dell Controler is Degraded

    - by Kyle Brandt
    I installed open manage on a couple of my PE 2950s for snmp monitoring of the RAID. All the checks seem to come back okay except for controllerState: [root@aMachine ~]# snmpwalk -v 2c -c bestNotToPostPasswords myMachine -m +StorageManagement-MIB controllerstate StorageManagement-MIB::controllerState.1 = INTEGER: degraded(6) Other checks seems to indicate the battery, LD, and physicals disks are all good unless I missing something. Can anyone tell if I am missing something or neglecting something import in my RAID monitoring/understanding? I get degraded for both these servers I have set up. A walk of the entire storage management tree for on of them: StorageManagement-MIB::softwareVersion.0 = STRING: "3.2.0" StorageManagement-MIB::globalStatus.0 = INTEGER: warning(2) StorageManagement-MIB::softwareManufacturer.0 = STRING: "Dell Inc." StorageManagement-MIB::softwareProduct.0 = STRING: "Server Administrator (Storage Management)" StorageManagement-MIB::softwareDescription.0 = STRING: "Configuration and monitoring of disk storage devices." StorageManagement-MIB::displayName.0 = STRING: "Server Administrator (Storage Management)" StorageManagement-MIB::description.0 = STRING: "Configuration and monitoring of disk storage devices." StorageManagement-MIB::agentVendor.0 = STRING: "Dell Inc." StorageManagement-MIB::agentTimeStamp.0 = INTEGER: 1273842310 StorageManagement-MIB::agentGetTimeout.0 = INTEGER: 5 StorageManagement-MIB::agentModifiers.0 = INTEGER: 0 StorageManagement-MIB::agentRefreshRate.0 = INTEGER: 300 StorageManagement-MIB::agentMibVersion.0 = STRING: "3.2" StorageManagement-MIB::agentManagementSoftwareURLName.0 = "" StorageManagement-MIB::agentGlobalSystemStatus.0 = INTEGER: nonCritical(4) StorageManagement-MIB::agentLastGlobalSystemStatus.0 = INTEGER: ok(3) StorageManagement-MIB::agentSmartThermalShutdown.0 = INTEGER: notApplicable(3) StorageManagement-MIB::controllerNumber.1 = INTEGER: 1 StorageManagement-MIB::controllerName.1 = STRING: "PERC 5/i Integrated" StorageManagement-MIB::controllerVendor.1 = STRING: "DELL" StorageManagement-MIB::controllerType.1 = INTEGER: sas(6) StorageManagement-MIB::controllerState.1 = INTEGER: degraded(6) StorageManagement-MIB::controllerRebuildRateInPercent.1 = INTEGER: 30 StorageManagement-MIB::controllerFWVersion.1 = STRING: "5.0.2-0003" StorageManagement-MIB::controllerCacheSizeInMB.1 = INTEGER: 256 StorageManagement-MIB::controllerCacheSizeInBytes.1 = INTEGER: 0 StorageManagement-MIB::controllerPhysicalDeviceCount.1 = INTEGER: 5 StorageManagement-MIB::controllerLogicalDeviceCount.1 = INTEGER: 1 StorageManagement-MIB::controllerRollUpStatus.1 = INTEGER: nonCritical(4) StorageManagement-MIB::controllerComponentStatus.1 = INTEGER: nonCritical(4) StorageManagement-MIB::controllerNexusID.1 = STRING: "\\0" StorageManagement-MIB::controllerAlarmState.1 = INTEGER: disabled(2) StorageManagement-MIB::controllerDriverVersion.1 = STRING: "00.00.03.05 " StorageManagement-MIB::controllerPCISlot.1 = STRING: "embedded" StorageManagement-MIB::controllerClusterMode.1 = INTEGER: notApplicable(99) StorageManagement-MIB::controllerMinFWVersion.1 = STRING: "5.2.1-0067" StorageManagement-MIB::controllerMinDriverVersion.1 = STRING: "00.00.03.21" StorageManagement-MIB::controllerChannelCount.1 = INTEGER: 2 StorageManagement-MIB::controllerReconstructRate.1 = INTEGER: 30 StorageManagement-MIB::controllerPatrolReadRate.1 = INTEGER: 30 StorageManagement-MIB::controllerBGIRate.1 = INTEGER: 30 StorageManagement-MIB::controllerCheckConsistencyRate.1 = INTEGER: 30 StorageManagement-MIB::controllerPatrolReadMode.1 = INTEGER: automatic(1) StorageManagement-MIB::controllerPatrolReadState.1 = INTEGER: stopped(1) StorageManagement-MIB::controllerPatrolReadIterations.1 = INTEGER: 162 StorageManagement-MIB::controllerEntry.57.1 = INTEGER: 99 StorageManagement-MIB::controllerEntry.58.1 = INTEGER: 99 StorageManagement-MIB::channelNumber.1 = INTEGER: 1 StorageManagement-MIB::channelNumber.2 = INTEGER: 2 StorageManagement-MIB::channelName.1 = STRING: "Connector 0" StorageManagement-MIB::channelName.2 = STRING: "Connector 1" StorageManagement-MIB::channelState.1 = INTEGER: ready(1) StorageManagement-MIB::channelState.2 = INTEGER: ready(1) StorageManagement-MIB::channelRollUpStatus.1 = INTEGER: ok(3) StorageManagement-MIB::channelRollUpStatus.2 = INTEGER: ok(3) StorageManagement-MIB::channelComponentStatus.1 = INTEGER: ok(3) StorageManagement-MIB::channelComponentStatus.2 = INTEGER: ok(3) StorageManagement-MIB::channelNexusID.1 = STRING: "\\0\\0" StorageManagement-MIB::channelNexusID.2 = STRING: "\\0\\1" StorageManagement-MIB::channelBusType.1 = INTEGER: sas(8) StorageManagement-MIB::channelBusType.2 = INTEGER: sas(8) StorageManagement-MIB::enclosureNumber.1 = INTEGER: 1 StorageManagement-MIB::enclosureName.1 = STRING: "Backplane" StorageManagement-MIB::enclosureVendor.1 = STRING: "DELL" StorageManagement-MIB::enclosureState.1 = INTEGER: ready(1) StorageManagement-MIB::enclosureProductID.1 = STRING: "BACKPLANE " StorageManagement-MIB::enclosureType.1 = INTEGER: internal(1) StorageManagement-MIB::enclosureChannelNumber.1 = INTEGER: 0 StorageManagement-MIB::enclosureRollUpStatus.1 = INTEGER: ok(3) StorageManagement-MIB::enclosureComponentStatus.1 = INTEGER: ok(3) StorageManagement-MIB::enclosureNexusID.1 = STRING: "\\0\\0\\0" StorageManagement-MIB::enclosureFirmwareVersion.1 = STRING: "1.00" StorageManagement-MIB::enclosureSASAddress.1 = STRING: "50019090B4C67200" StorageManagement-MIB::arrayDiskNumber.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskNumber.2 = INTEGER: 2 StorageManagement-MIB::arrayDiskNumber.3 = INTEGER: 3 StorageManagement-MIB::arrayDiskNumber.4 = INTEGER: 4 StorageManagement-MIB::arrayDiskName.1 = STRING: "Physical Disk 0:0:0" StorageManagement-MIB::arrayDiskName.2 = STRING: "Physical Disk 0:0:1" StorageManagement-MIB::arrayDiskName.3 = STRING: "Physical Disk 0:0:2" StorageManagement-MIB::arrayDiskName.4 = STRING: "Physical Disk 0:0:3" StorageManagement-MIB::arrayDiskVendor.1 = STRING: "DELL " StorageManagement-MIB::arrayDiskVendor.2 = STRING: "DELL " StorageManagement-MIB::arrayDiskVendor.3 = STRING: "DELL " StorageManagement-MIB::arrayDiskVendor.4 = STRING: "DELL " StorageManagement-MIB::arrayDiskState.1 = INTEGER: online(3) StorageManagement-MIB::arrayDiskState.2 = INTEGER: online(3) StorageManagement-MIB::arrayDiskState.3 = INTEGER: online(3) StorageManagement-MIB::arrayDiskState.4 = INTEGER: online(3) StorageManagement-MIB::arrayDiskProductID.1 = STRING: "ST3146755SS " StorageManagement-MIB::arrayDiskProductID.2 = STRING: "ST3146755SS " StorageManagement-MIB::arrayDiskProductID.3 = STRING: "ST3146755SS " StorageManagement-MIB::arrayDiskProductID.4 = STRING: "ST3146755SS " StorageManagement-MIB::arrayDiskSerialNo.1 = STRING: "3LN0LRL0 " StorageManagement-MIB::arrayDiskSerialNo.2 = STRING: "3LN0JYJS " StorageManagement-MIB::arrayDiskSerialNo.3 = STRING: "3LN0LR0V " StorageManagement-MIB::arrayDiskSerialNo.4 = STRING: "3LN0JH97 " StorageManagement-MIB::arrayDiskRevision.1 = STRING: "T106" StorageManagement-MIB::arrayDiskRevision.2 = STRING: "T106" StorageManagement-MIB::arrayDiskRevision.3 = STRING: "T106" StorageManagement-MIB::arrayDiskRevision.4 = STRING: "T106" StorageManagement-MIB::arrayDiskEnclosureID.1 = STRING: "0" StorageManagement-MIB::arrayDiskEnclosureID.2 = STRING: "0" StorageManagement-MIB::arrayDiskEnclosureID.3 = STRING: "0" StorageManagement-MIB::arrayDiskEnclosureID.4 = STRING: "0" StorageManagement-MIB::arrayDiskChannel.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskChannel.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskChannel.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskChannel.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskLengthInMB.1 = INTEGER: 139392 StorageManagement-MIB::arrayDiskLengthInMB.2 = INTEGER: 139392 StorageManagement-MIB::arrayDiskLengthInMB.3 = INTEGER: 139392 StorageManagement-MIB::arrayDiskLengthInMB.4 = INTEGER: 139392 StorageManagement-MIB::arrayDiskLengthInBytes.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskLengthInBytes.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskLengthInBytes.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskLengthInBytes.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInMB.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInMB.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInMB.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInMB.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInBytes.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInBytes.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInBytes.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInBytes.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskTargetID.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskTargetID.2 = INTEGER: 1 StorageManagement-MIB::arrayDiskTargetID.3 = INTEGER: 2 StorageManagement-MIB::arrayDiskTargetID.4 = INTEGER: 3 StorageManagement-MIB::arrayDiskLunID.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskLunID.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskLunID.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskLunID.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskUsedSpaceInMB.1 = INTEGER: 139392 StorageManagement-MIB::arrayDiskUsedSpaceInMB.2 = INTEGER: 139392 StorageManagement-MIB::arrayDiskUsedSpaceInMB.3 = INTEGER: 139392 StorageManagement-MIB::arrayDiskUsedSpaceInMB.4 = INTEGER: 139392 StorageManagement-MIB::arrayDiskUsedSpaceInBytes.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskUsedSpaceInBytes.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskUsedSpaceInBytes.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskUsedSpaceInBytes.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskFreeSpaceInMB.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskFreeSpaceInMB.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskFreeSpaceInMB.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskFreeSpaceInMB.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskFreeSpaceInBytes.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskFreeSpaceInBytes.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskFreeSpaceInBytes.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskFreeSpaceInBytes.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskBusType.1 = INTEGER: sas(8) StorageManagement-MIB::arrayDiskBusType.2 = INTEGER: sas(8) StorageManagement-MIB::arrayDiskBusType.3 = INTEGER: sas(8) StorageManagement-MIB::arrayDiskBusType.4 = INTEGER: sas(8) StorageManagement-MIB::arrayDiskSpareState.1 = INTEGER: notASpare(5) StorageManagement-MIB::arrayDiskSpareState.2 = INTEGER: notASpare(5) StorageManagement-MIB::arrayDiskSpareState.3 = INTEGER: notASpare(5) StorageManagement-MIB::arrayDiskSpareState.4 = INTEGER: notASpare(5) StorageManagement-MIB::arrayDiskRollUpStatus.1 = INTEGER: ok(3) StorageManagement-MIB::arrayDiskRollUpStatus.2 = INTEGER: ok(3) StorageManagement-MIB::arrayDiskRollUpStatus.3 = INTEGER: ok(3) StorageManagement-MIB::arrayDiskRollUpStatus.4 = INTEGER: ok(3) StorageManagement-MIB::arrayDiskComponentStatus.1 = INTEGER: ok(3) StorageManagement-MIB::arrayDiskComponentStatus.2 = INTEGER: ok(3) StorageManagement-MIB::arrayDiskComponentStatus.3 = INTEGER: ok(3) StorageManagement-MIB::arrayDiskComponentStatus.4 = INTEGER: ok(3) StorageManagement-MIB::arrayDiskNexusID.1 = STRING: "\\0\\0\\0\\0" StorageManagement-MIB::arrayDiskNexusID.2 = STRING: "\\0\\0\\0\\1" StorageManagement-MIB::arrayDiskNexusID.3 = STRING: "\\0\\0\\0\\2" StorageManagement-MIB::arrayDiskNexusID.4 = STRING: "\\0\\0\\0\\3" StorageManagement-MIB::arrayDiskPartNumber.1 = STRING: "SG0DR2381253172FLRL0A00 " StorageManagement-MIB::arrayDiskPartNumber.2 = STRING: "SG0DR2381253172FJYJSA00 " StorageManagement-MIB::arrayDiskPartNumber.3 = STRING: "SG0DR2381253172FLR0VA00 " StorageManagement-MIB::arrayDiskPartNumber.4 = STRING: "SG0DR2381253172FJH97A00 " StorageManagement-MIB::arrayDiskSASAddress.1 = STRING: "5000C50002380201" StorageManagement-MIB::arrayDiskSASAddress.2 = STRING: "5000C50002385B89" StorageManagement-MIB::arrayDiskSASAddress.3 = STRING: "5000C50002385AA9" StorageManagement-MIB::arrayDiskSASAddress.4 = STRING: "5000C500023841E1" StorageManagement-MIB::arrayDiskSmartAlertIndication.1 = INTEGER: no(1) StorageManagement-MIB::arrayDiskSmartAlertIndication.2 = INTEGER: no(1) StorageManagement-MIB::arrayDiskSmartAlertIndication.3 = INTEGER: no(1) StorageManagement-MIB::arrayDiskSmartAlertIndication.4 = INTEGER: no(1) StorageManagement-MIB::arrayDiskManufactureDay.1 = STRING: "07" StorageManagement-MIB::arrayDiskManufactureDay.2 = STRING: "07" StorageManagement-MIB::arrayDiskManufactureDay.3 = STRING: "07" StorageManagement-MIB::arrayDiskManufactureDay.4 = STRING: "07" StorageManagement-MIB::arrayDiskManufactureWeek.1 = STRING: "07" StorageManagement-MIB::arrayDiskManufactureWeek.2 = STRING: "07" StorageManagement-MIB::arrayDiskManufactureWeek.3 = STRING: "07" StorageManagement-MIB::arrayDiskManufactureWeek.4 = STRING: "07" StorageManagement-MIB::arrayDiskManufactureYear.1 = STRING: "2005" StorageManagement-MIB::arrayDiskManufactureYear.2 = STRING: "2005" StorageManagement-MIB::arrayDiskManufactureYear.3 = STRING: "2005" StorageManagement-MIB::arrayDiskManufactureYear.4 = STRING: "2005" StorageManagement-MIB::arrayDiskMediaType.1 = INTEGER: hdd(2) StorageManagement-MIB::arrayDiskMediaType.2 = INTEGER: hdd(2) StorageManagement-MIB::arrayDiskMediaType.3 = INTEGER: hdd(2) StorageManagement-MIB::arrayDiskMediaType.4 = INTEGER: hdd(2) StorageManagement-MIB::arrayDiskEntry.36.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskEntry.36.2 = INTEGER: 1 StorageManagement-MIB::arrayDiskEntry.36.3 = INTEGER: 1 StorageManagement-MIB::arrayDiskEntry.36.4 = INTEGER: 1 StorageManagement-MIB::arrayDiskEntry.40.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskEntry.40.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskEntry.40.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskEntry.40.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskEntry.41.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskEntry.41.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskEntry.41.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskEntry.41.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskEnclosureConnectionNumber.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionNumber.2 = INTEGER: 2 StorageManagement-MIB::arrayDiskEnclosureConnectionNumber.3 = INTEGER: 3 StorageManagement-MIB::arrayDiskEnclosureConnectionNumber.4 = INTEGER: 4 StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskName.1 = STRING: "Physical Disk 0:0:0" StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskName.2 = STRING: "Physical Disk 0:0:1" StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskName.3 = STRING: "Physical Disk 0:0:2" StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskName.4 = STRING: "Physical Disk 0:0:3" StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskNumber.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskNumber.2 = INTEGER: 2 StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskNumber.3 = INTEGER: 3 StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskNumber.4 = INTEGER: 4 StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureName.1 = STRING: "Backplane" StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureName.2 = STRING: "Backplane" StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureName.3 = STRING: "Backplane" StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureName.4 = STRING: "Backplane" StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureNumber.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureNumber.2 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureNumber.3 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureNumber.4 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionControllerName.1 = STRING: "PERC 5/i Integrated" StorageManagement-MIB::arrayDiskEnclosureConnectionControllerName.2 = STRING: "PERC 5/i Integrated" StorageManagement-MIB::arrayDiskEnclosureConnectionControllerName.3 = STRING: "PERC 5/i Integrated" StorageManagement-MIB::arrayDiskEnclosureConnectionControllerName.4 = STRING: "PERC 5/i Integrated" StorageManagement-MIB::arrayDiskEnclosureConnectionControllerNumber.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionControllerNumber.2 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionControllerNumber.3 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionControllerNumber.4 = INTEGER: 1 StorageManagement-MIB::batteryNumber.1 = INTEGER: 1 StorageManagement-MIB::batteryName.1 = STRING: "Battery 0" StorageManagement-MIB::batteryVendor.1 = STRING: "DELL" StorageManagement-MIB::batteryState.1 = INTEGER: ready(1) StorageManagement-MIB::batteryRollUpStatus.1 = INTEGER: ok(3) StorageManagement-MIB::batteryComponentStatus.1 = INTEGER: ok(3) StorageManagement-MIB::batteryNexusID.1 = STRING: "\\0\\0" StorageManagement-MIB::batteryPredictedCapacity.1 = INTEGER: ready(2) StorageManagement-MIB::batteryNextLearnTime.1 = INTEGER: 21 StorageManagement-MIB::batteryLearnState.1 = INTEGER: idle(16) StorageManagement-MIB::batteryEntry.13.1 = INTEGER: 0 StorageManagement-MIB::batteryMaxLearnDelay.1 = INTEGER: 168 StorageManagement-MIB::batteryConnectionNumber.1 = INTEGER: 1 StorageManagement-MIB::batteryConnectionBatteryName.1 = STRING: "Battery 0" StorageManagement-MIB::batteryConnectionBatteryNumber.1 = INTEGER: 1 StorageManagement-MIB::batteryConnectionControllerName.1 = STRING: "PERC 5/i Integrated" StorageManagement-MIB::batteryConnectionControllerNumber.1 = INTEGER: 1 StorageManagement-MIB::virtualDiskNumber.1 = INTEGER: 1 StorageManagement-MIB::virtualDiskName.1 = STRING: "Virtual Disk 0" StorageManagement-MIB::virtualDiskDeviceName.1 = STRING: "/dev/sda" StorageManagement-MIB::virtualDiskState.1 = INTEGER: ready(1) StorageManagement-MIB::virtualDiskLengthInMB.1 = INTEGER: 278784 StorageManagement-MIB::virtualDiskLengthInBytes.1 = INTEGER: 0 StorageManagement-MIB::virtualDiskWritePolicy.1 = INTEGER: writeBack(3) StorageManagement-MIB::virtualDiskReadPolicy.1 = INTEGER: noReadAhead(5) StorageManagement-MIB::virtualDiskCachePolicy.1 = INTEGER: not-applicable(99) StorageManagement-MIB::virtualDiskLayout.1 = INTEGER: raid-10(10) StorageManagement-MIB::virtualDiskCurStripeSizeInMB.1 = INTEGER: 0 StorageManagement-MIB::virtualDiskCurStripeSizeInBytes.1 = INTEGER: 65536 StorageManagement-MIB::virtualDiskTargetID.1 = INTEGER: 0 StorageManagement-MIB::virtualDiskRollUpStatus.1 = INTEGER: ok(3) StorageManagement-MIB::virtualDiskComponentStatus.1 = INTEGER: ok(3) StorageManagement-MIB::virtualDiskNexusID.1 = STRING: "\\0\\0" StorageManagement-MIB::virtualDiskArrayDiskType.1 = INTEGER: sas(1) StorageManagement-MIB::virtualDiskEntry.23.1 = INTEGER: 2 StorageManagement-MIB::virtualDiskEntry.24.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskLogicalConnectionNumber.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskLogicalConnectionNumber.2 = INTEGER: 2 StorageManagement-MIB::arrayDiskLogicalConnectionNumber.3 = INTEGER: 3 StorageManagement-MIB::arrayDiskLogicalConnectionNumber.4 = INTEGER: 4 StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskName.1 = STRING: "Physical Disk 0:0:0" StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskName.2 = STRING: "Physical Disk 0:0:1" StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskName.3 = STRING: "Physical Disk 0:0:2" StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskName.4 = STRING: "Physical Disk 0:0:3" StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskNumber.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskNumber.2 = INTEGER: 2 StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskNumber.3 = INTEGER: 3 StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskNumber.4 = INTEGER: 4 StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskName.1 = STRING: "Virtual Disk 0" StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskName.2 = STRING: "Virtual Disk 0" StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskName.3 = STRING: "Virtual Disk 0" StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskName.4 = STRING: "Virtual Disk 0" StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskNumber.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskNumber.2 = INTEGER: 1 StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskNumber.3 = INTEGER: 1 StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskNumber.4 = INTEGER: 1

    Read the article

  • Turn computer into DAS (Direct Attached Storage)

    - by Damon
    Can we build a direct attached storage by taking a computer/server, adding an HBA, and installing some appropriate software? We would use Debian as a host OS for both the DAS and the server. If so, what software do we use? And do we simply need a HBA for the DAS and the Server? Or do we need more hardware? The goal is to use an older server that does not have enough room for drives but does have ECC memory, server processors, redundant power supplies, dual nics, etc. Then find any boxes, server or not, the key being having enough room for 8-12 drives, fans, etc. and turning them into a DAS; build two of these DAS's and have them connected to the server. Eventually we want to have two servers using DRBD and associated services like heartbeat and pace maker to create an HA setup for our server(s) but that will take a long time to configure since I have no experience with anything related to DRBD (yet) and have a learning curve I have to get past, not to mention the additional cost of more hardware (two servers vs one).

    Read the article

  • e2fsck / resize2fs problems

    - by BlakBat
    I've got 6 drives (each 1.5T, all same model and firmware revision) that are part of a RAID5 array. The RAID5 makes a LVM volume group and a logical group. The latter contains only one ext3 partition. I've recently ran: e2fsck -f /dev/vg03/lv01 && resize2fs -M /dev/vg03/lv01 which exited without an error. Now when I try to mount /dev/vg03/lv01 I get: EXT3-fs error (device dm-0): ext3_check_descriptors: Block bitmap for group 30533 not in group (block 1000532368)! EXT3-fs: group descriptors corrupted! How do I get out of this predicament? This is all the info I can currently give you: fdisk -l /dev/sd[cdefgh] shows (correctly) that they are "Linux raid autodetect" but fdisk now shows: fdisk -l /dev/md0 Disk /dev/md0: 7501.5 GB, 7501495664640 bytes ... Disk identifier: 0x00000000 Disk /dev/md0 doesn't contain a valid partition table (instead of a LVM type partition) fdisk -l /dev/vg03/lv01 Disk /dev/vg03/lv01: 7501.5 GB, 7501491732480 bytes ... Disk identifier: 0x00000000 Disk /dev/vg03/lv01 doesn't contain a valid partition table (instead of a ext3 type partition) I've tried: e2fsck -fy /dev/vg03/lv01 e2fsck 1.41.12 (17-May-2010) e2fsck: Group descriptors look bad... trying backup blocks... Block bitmap for group 30533 is not in group. (block 1000532368) Relocate? yes Inode bitmap for group 30533 is not in group. (block 1000532369) Relocate? yes Pass 1: Checking inodes, blocks, and sizes Relocating group 30533's block bitmap to 1000524246... Error allocating 1 contiguous block(s) in block group 30533 for inode bitmap: Could not allocate block in ext2 filesystem e2fsck: aborted Extra information I can give you: cat /proc/mdstat Personalities : [linear] [multipath] [raid0] [raid1] [raid6] [raid5] [raid4] [raid10] md0 : active (auto-read-only) raid5 sdg1[0] sdh1[5] sdf1[4] sde1[3] sdc1[2] sdd1[1] 7325679360 blocks level 5, 128k chunk, algorithm 2 [6/6] [UUUUUU] bitmap: 1/175 pages [4KB], 4096KB chunk unused devices: Lastly, all smartctl tests (short and extendend) showed no errors on any of the disks. Should I try to resize2fs to grow /dev/vg03/lv01 and redo a e2fsck ? Should I cfdisk /dev/md0 and /dev/vg03/lv01 back to their real types? Thanks in advance for all and any help. 2011-09-20 UPDATE I issued the following commands and was able to remount the partition, but by viewing the size (df) of before and after, it seems that 1Tb of data have gone missing. By checking the MD5SUMS (from an old backup) of some files with the "same" files from the remounted partition, some errors have been detected. Commands issued to remount the partition were: dumpe2fs /dev/vg03/lv01 Block count: 1000491435<br /> Block size: 4096<br /> tune2fs -O ^has_journal /dev/vg03/lv01 resize2fs -p /dev/vg03/lv01 dumpe2fs /dev/vg03/lv01 Block count: 1831418880<br /> Block size: 4096<br /> mount -o ro,noatime /dev/vg03/lv01 /mnt/raid OK... but files have been damaged / gone missing.

    Read the article

  • LSI 9285-8e and Supermicro SC837E26-RJBOD1 duplicate enclosure ID and slot numbers

    - by Andy Shinn
    I am working with 2 x Supermicro SC837E26-RJBOD1 chassis connected to a single LSI 9285-8e card in a Supermicro 1U host. There are 28 drives in each chassis for a total of 56 drives in 28 RAID1 mirrors. The problem I am running in to is that there are duplicate slots for the 2 chassis (the slots list twice and only go from 0 to 27). All the drives also show the same enclosure ID (ID 36). However, MegaCLI -encinfo lists the 2 enclosures correctly (ID 36 and ID 65). My question is, why would this happen? Is there an option I am missing to use 2 enclosures effectively? This is blocking me rebuilding a drive that failed in slot 11 since I can only specify enclosure and slot as parameters to replace a drive. When I do this, it picks the wrong slot 11 (device ID 46 instead of device ID 19). Adapter #1 is the LSI 9285-8e, adapter #0 (which I removed due to space limitations) is the onboard LSI. Adapter information: Adapter #1 ============================================================================== Versions ================ Product Name : LSI MegaRAID SAS 9285-8e Serial No : SV12704804 FW Package Build: 23.1.1-0004 Mfg. Data ================ Mfg. Date : 06/30/11 Rework Date : 00/00/00 Revision No : 00A Battery FRU : N/A Image Versions in Flash: ================ BIOS Version : 5.25.00_4.11.05.00_0x05040000 WebBIOS Version : 6.1-20-e_20-Rel Preboot CLI Version: 05.01-04:#%00001 FW Version : 3.140.15-1320 NVDATA Version : 2.1106.03-0051 Boot Block Version : 2.04.00.00-0001 BOOT Version : 06.253.57.219 Pending Images in Flash ================ None PCI Info ================ Vendor Id : 1000 Device Id : 005b SubVendorId : 1000 SubDeviceId : 9285 Host Interface : PCIE ChipRevision : B0 Number of Frontend Port: 0 Device Interface : PCIE Number of Backend Port: 8 Port : Address 0 5003048000ee8e7f 1 5003048000ee8a7f 2 0000000000000000 3 0000000000000000 4 0000000000000000 5 0000000000000000 6 0000000000000000 7 0000000000000000 HW Configuration ================ SAS Address : 500605b0038f9210 BBU : Present Alarm : Present NVRAM : Present Serial Debugger : Present Memory : Present Flash : Present Memory Size : 1024MB TPM : Absent On board Expander: Absent Upgrade Key : Absent Temperature sensor for ROC : Present Temperature sensor for controller : Absent ROC temperature : 70 degree Celcius Settings ================ Current Time : 18:24:36 3/13, 2012 Predictive Fail Poll Interval : 300sec Interrupt Throttle Active Count : 16 Interrupt Throttle Completion : 50us Rebuild Rate : 30% PR Rate : 30% BGI Rate : 30% Check Consistency Rate : 30% Reconstruction Rate : 30% Cache Flush Interval : 4s Max Drives to Spinup at One Time : 2 Delay Among Spinup Groups : 12s Physical Drive Coercion Mode : Disabled Cluster Mode : Disabled Alarm : Enabled Auto Rebuild : Enabled Battery Warning : Enabled Ecc Bucket Size : 15 Ecc Bucket Leak Rate : 1440 Minutes Restore HotSpare on Insertion : Disabled Expose Enclosure Devices : Enabled Maintain PD Fail History : Enabled Host Request Reordering : Enabled Auto Detect BackPlane Enabled : SGPIO/i2c SEP Load Balance Mode : Auto Use FDE Only : No Security Key Assigned : No Security Key Failed : No Security Key Not Backedup : No Default LD PowerSave Policy : Controller Defined Maximum number of direct attached drives to spin up in 1 min : 10 Any Offline VD Cache Preserved : No Allow Boot with Preserved Cache : No Disable Online Controller Reset : No PFK in NVRAM : No Use disk activity for locate : No Capabilities ================ RAID Level Supported : RAID0, RAID1, RAID5, RAID6, RAID00, RAID10, RAID50, RAID60, PRL 11, PRL 11 with spanning, SRL 3 supported, PRL11-RLQ0 DDF layout with no span, PRL11-RLQ0 DDF layout with span Supported Drives : SAS, SATA Allowed Mixing: Mix in Enclosure Allowed Mix of SAS/SATA of HDD type in VD Allowed Status ================ ECC Bucket Count : 0 Limitations ================ Max Arms Per VD : 32 Max Spans Per VD : 8 Max Arrays : 128 Max Number of VDs : 64 Max Parallel Commands : 1008 Max SGE Count : 60 Max Data Transfer Size : 8192 sectors Max Strips PerIO : 42 Max LD per array : 16 Min Strip Size : 8 KB Max Strip Size : 1.0 MB Max Configurable CacheCade Size: 0 GB Current Size of CacheCade : 0 GB Current Size of FW Cache : 887 MB Device Present ================ Virtual Drives : 28 Degraded : 0 Offline : 0 Physical Devices : 59 Disks : 56 Critical Disks : 0 Failed Disks : 0 Supported Adapter Operations ================ Rebuild Rate : Yes CC Rate : Yes BGI Rate : Yes Reconstruct Rate : Yes Patrol Read Rate : Yes Alarm Control : Yes Cluster Support : No BBU : No Spanning : Yes Dedicated Hot Spare : Yes Revertible Hot Spares : Yes Foreign Config Import : Yes Self Diagnostic : Yes Allow Mixed Redundancy on Array : No Global Hot Spares : Yes Deny SCSI Passthrough : No Deny SMP Passthrough : No Deny STP Passthrough : No Support Security : No Snapshot Enabled : No Support the OCE without adding drives : Yes Support PFK : Yes Support PI : No Support Boot Time PFK Change : Yes Disable Online PFK Change : No PFK TrailTime Remaining : 0 days 0 hours Support Shield State : Yes Block SSD Write Disk Cache Change: Yes Supported VD Operations ================ Read Policy : Yes Write Policy : Yes IO Policy : Yes Access Policy : Yes Disk Cache Policy : Yes Reconstruction : Yes Deny Locate : No Deny CC : No Allow Ctrl Encryption: No Enable LDBBM : No Support Breakmirror : No Power Savings : Yes Supported PD Operations ================ Force Online : Yes Force Offline : Yes Force Rebuild : Yes Deny Force Failed : No Deny Force Good/Bad : No Deny Missing Replace : No Deny Clear : No Deny Locate : No Support Temperature : Yes Disable Copyback : No Enable JBOD : No Enable Copyback on SMART : No Enable Copyback to SSD on SMART Error : Yes Enable SSD Patrol Read : No PR Correct Unconfigured Areas : Yes Enable Spin Down of UnConfigured Drives : Yes Disable Spin Down of hot spares : No Spin Down time : 30 T10 Power State : Yes Error Counters ================ Memory Correctable Errors : 0 Memory Uncorrectable Errors : 0 Cluster Information ================ Cluster Permitted : No Cluster Active : No Default Settings ================ Phy Polarity : 0 Phy PolaritySplit : 0 Background Rate : 30 Strip Size : 64kB Flush Time : 4 seconds Write Policy : WB Read Policy : Adaptive Cache When BBU Bad : Disabled Cached IO : No SMART Mode : Mode 6 Alarm Disable : Yes Coercion Mode : None ZCR Config : Unknown Dirty LED Shows Drive Activity : No BIOS Continue on Error : No Spin Down Mode : None Allowed Device Type : SAS/SATA Mix Allow Mix in Enclosure : Yes Allow HDD SAS/SATA Mix in VD : Yes Allow SSD SAS/SATA Mix in VD : No Allow HDD/SSD Mix in VD : No Allow SATA in Cluster : No Max Chained Enclosures : 16 Disable Ctrl-R : Yes Enable Web BIOS : Yes Direct PD Mapping : No BIOS Enumerate VDs : Yes Restore Hot Spare on Insertion : No Expose Enclosure Devices : Yes Maintain PD Fail History : Yes Disable Puncturing : No Zero Based Enclosure Enumeration : No PreBoot CLI Enabled : Yes LED Show Drive Activity : Yes Cluster Disable : Yes SAS Disable : No Auto Detect BackPlane Enable : SGPIO/i2c SEP Use FDE Only : No Enable Led Header : No Delay during POST : 0 EnableCrashDump : No Disable Online Controller Reset : No EnableLDBBM : No Un-Certified Hard Disk Drives : Allow Treat Single span R1E as R10 : No Max LD per array : 16 Power Saving option : Don't Auto spin down Configured Drives Max power savings option is not allowed for LDs. Only T10 power conditions are to be used. Default spin down time in minutes: 30 Enable JBOD : No TTY Log In Flash : No Auto Enhanced Import : No BreakMirror RAID Support : No Disable Join Mirror : No Enable Shield State : Yes Time taken to detect CME : 60s Exit Code: 0x00 Enclosure information: # /opt/MegaRAID/MegaCli/MegaCli64 -encinfo -a1 Number of enclosures on adapter 1 -- 3 Enclosure 0: Device ID : 36 Number of Slots : 28 Number of Power Supplies : 2 Number of Fans : 3 Number of Temperature Sensors : 1 Number of Alarms : 1 Number of SIM Modules : 0 Number of Physical Drives : 28 Status : Normal Position : 1 Connector Name : Port B Enclosure type : SES VendorId is LSI CORP and Product Id is SAS2X36 VendorID and Product ID didnt match FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : 65 Inquiry data : Vendor Identification : LSI CORP Product Identification : SAS2X36 Product Revision Level : 0718 Vendor Specific : x36-55.7.24.1 Number of Voltage Sensors :2 Voltage Sensor :0 Voltage Sensor Status :OK Voltage Value :5020 milli volts Voltage Sensor :1 Voltage Sensor Status :OK Voltage Value :11820 milli volts Number of Power Supplies : 2 Power Supply : 0 Power Supply Status : OK Power Supply : 1 Power Supply Status : OK Number of Fans : 3 Fan : 0 Fan Speed :Low Speed Fan Status : OK Fan : 1 Fan Speed :Low Speed Fan Status : OK Fan : 2 Fan Speed :Low Speed Fan Status : OK Number of Temperature Sensors : 1 Temp Sensor : 0 Temperature : 48 Temperature Sensor Status : OK Number of Chassis : 1 Chassis : 0 Chassis Status : OK Enclosure 1: Device ID : 65 Number of Slots : 28 Number of Power Supplies : 2 Number of Fans : 3 Number of Temperature Sensors : 1 Number of Alarms : 1 Number of SIM Modules : 0 Number of Physical Drives : 28 Status : Normal Position : 1 Connector Name : Port A Enclosure type : SES VendorId is LSI CORP and Product Id is SAS2X36 VendorID and Product ID didnt match FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : 36 Inquiry data : Vendor Identification : LSI CORP Product Identification : SAS2X36 Product Revision Level : 0718 Vendor Specific : x36-55.7.24.1 Number of Voltage Sensors :2 Voltage Sensor :0 Voltage Sensor Status :OK Voltage Value :5020 milli volts Voltage Sensor :1 Voltage Sensor Status :OK Voltage Value :11760 milli volts Number of Power Supplies : 2 Power Supply : 0 Power Supply Status : OK Power Supply : 1 Power Supply Status : OK Number of Fans : 3 Fan : 0 Fan Speed :Low Speed Fan Status : OK Fan : 1 Fan Speed :Low Speed Fan Status : OK Fan : 2 Fan Speed :Low Speed Fan Status : OK Number of Temperature Sensors : 1 Temp Sensor : 0 Temperature : 47 Temperature Sensor Status : OK Number of Chassis : 1 Chassis : 0 Chassis Status : OK Enclosure 2: Device ID : 252 Number of Slots : 8 Number of Power Supplies : 0 Number of Fans : 0 Number of Temperature Sensors : 0 Number of Alarms : 0 Number of SIM Modules : 1 Number of Physical Drives : 0 Status : Normal Position : 1 Connector Name : Unavailable Enclosure type : SGPIO Failed in first Inquiry commnad FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : Unavailable Inquiry data : Vendor Identification : LSI Product Identification : SGPIO Product Revision Level : N/A Vendor Specific : Exit Code: 0x00 Now, notice that each slot 11 device shows an enclosure ID of 36, I think this is where the discrepancy happens. One should be 36. But the other should be on enclosure 65. Drives in slot 11: Enclosure Device ID: 36 Slot Number: 11 Drive's postion: DiskGroup: 5, Span: 0, Arm: 1 Enclosure position: 0 Device Id: 48 WWN: Sequence Number: 11 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Firmware state: Online, Spun Up Is Commissioned Spare : YES Device Firmware Level: A5C0 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5003048000ee8a53 Connected Port Number: 1(path0) Inquiry Data: MJ1311YNG6YYXAHitachi HDS5C3030ALA630 MEAOA5C0 FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :30C (86.00 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Drive's write cache : Disabled Drive's NCQ setting : Enabled Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No Enclosure Device ID: 36 Slot Number: 11 Drive's postion: DiskGroup: 19, Span: 0, Arm: 1 Enclosure position: 0 Device Id: 19 WWN: Sequence Number: 4 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Firmware state: Online, Spun Up Is Commissioned Spare : NO Device Firmware Level: A580 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5003048000ee8e53 Connected Port Number: 0(path0) Inquiry Data: MJ1313YNG1VA5CHitachi HDS5C3030ALA630 MEAOA580 FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :30C (86.00 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Drive's write cache : Disabled Drive's NCQ setting : Enabled Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No Update 06/28/12: I finally have some new information about (what we think) the root cause of this problem so I thought I would share. After getting in contact with a very knowledgeable Supermicro tech, they provided us with a tool called Xflash (doesn't appear to be readily available on their FTP). When we gathered some information using this utility, my colleague found something very strange: root@mogile2 test]# ./xflash.dat -i get avail Initializing Interface. Expander: SAS2X36 (SAS2x36) 1) SAS2X36 (SAS2x36) (50030480:00EE917F) (0.0.0.0) 2) SAS2X36 (SAS2x36) (50030480:00E9D67F) (0.0.0.0) 3) SAS2X36 (SAS2x36) (50030480:0112D97F) (0.0.0.0) This lists the connected enclosures. You see the 3 connected (we have since added a 3rd and a 4th which is not yet showing up) with their respective SAS address / WWN (50030480:00EE917F). Now we can use this address to get information on the individual enclosures: [root@mogile2 test]# ./xflash.dat -i 5003048000EE917F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:00EE917F Enclosure Logical Id: 50030480:0000007F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 [root@mogile2 test]# ./xflash.dat -i 5003048000E9D67F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:00E9D67F Enclosure Logical Id: 50030480:0000007F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 [root@mogile2 test]# ./xflash.dat -i 500304800112D97F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:0112D97F Enclosure Logical Id: 50030480:0112D97F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 Did you catch it? The first 2 enclosures logical ID is partially masked out where the 3rd one (which has a correct unique enclosure ID) is not. We pointed this out to Supermicro and were able to confirm that this address is supposed to be set during manufacturing and there was a problem with a certain batch of these enclosures where the logical ID was not set. We believe that the RAID controller is determining the ID based on the logical ID and since our first 2 enclosures have the same logical ID, they get the same enclosure ID. We also confirmed that 0000007F is the default which comes from LSI as an ID. The next pointer that helps confirm this could be a manufacturing problem with a run of JBODs is the fact that all 6 of the enclosures that have this problem begin with 00E. I believe that between 00E8 and 00EE Supermicro forgot to program the logical IDs correctly and neglected to recall or fix the problem post production. Fortunately for us, there is a tool to manage the WWN and logical ID of the devices from Supermicro: ftp://ftp.supermicro.com/utility/ExpanderXtools_Lite/. Our next step is to schedule a shutdown of these JBODs (after data migration) and reprogram the logical ID and see if it solves the problem. Update 06/28/12 #2: I just discovered this FAQ at Supermicro while Google searching for "lsi 0000007f": http://www.supermicro.com/support/faqs/faq.cfm?faq=11805. I still don't understand why, in the last several times we contacted Supermicro, they would have never directed us to this article :\

    Read the article

  • MCV/MVP Patterns and Applications that interface with Hardware (DAQ/PLC/etc)

    - by Ryan
    I've been reading a lot about the MCV and MVP patterns for use with UI and it seems like a really nice powerful way to handle user interfaces. I am - however - having a difficult time deciding how this could integrate into a system where data in the model is created from a Data Acquisition System or Serial/Ethernet devices. There is also the added step that 70% of application interaction is performed by a PLC instead of a live user. It seems that for apps that just read/write & manipulate information from a database this works great, but how does does hardware and automation fit into these patterns? Is it as simple as another controller (for lack of a better term) that interacts with hardware that manipulates data and writes to a model? Maybe I am over thinking this or thinking too simply, so any advice would be great. I'm not quite sure where I'm going with this, so if something doesn't make sense or I was too vague leave me a comment. Thanks!

    Read the article

  • How do I open a hardware accelarated DirectX window on a secondary screen

    - by user567021
    I'm looking to create a hardware accelarated DirectX (9 at the moment) window on a secondary screen. This screen is connected to the same graphics display as the primary screen (at least at the moment). Currently, when I try to open the window on the secondary screen based on window position or by dragging it there, CPU usage jumps by about 10%, which seems to indicate that windows is switching to a software fallback rather than the hardware accelaration. Machine is windows XP running a NVIDIA graphics card (varying cards as this runs on several machines), with the latest driver. It's also running CUDA at the same time to produce the images if that matters. Programming language is c++, manual window and message queue creation, no tookbox used at the moment to manage the GUI Thanks

    Read the article

  • 2D Engine scrolling on OpenGL via hardware?

    - by drudru
    hi, I'm using OpenGL as the bottom end for a 2D tiling engine. When everything is 2D, it is simple to optimize certain issues. For example, scrolling. If I know a certain section of the screen needs to scroll off the bottom, then I can just blit over that portion. I'm evening moving more than 1 pixel at a time. Without explicit hardware support (think old nintendo hw), this requires a lot of pixel writes. An on chip bitblt would be the next best thing. Essentially, I'm looking at how I can optimize my GL calls to use VRAM texture renders as efficient hardware blits. Is it possible to have GL scroll the framebuffer, or should I just resign myself to double-buffering and re-rendering an entire scene for each frame? Thx

    Read the article

  • How can I remotely tell what brand/model internal SCSI card is installed in a machine?

    - by edmicman
    I am doing some consulting work for a previous employer upgrading and migrating old servers to new hardware. There is an existing file server (HP ProLiant DL380) that has an tape backup drive connected; it is using a SCSI interface and I'm pretty sure it's using an internal SCSI card. They are upgrading to a new server hardware (HP ProLiant DL160 G6). The old server is 2U, the new one 1U and we would want to move the tape drive to the new server, too. I'm trying to figure out if the SCSI card in the old server would be able to be installed in the new one or if we'll need to source a new card; mostly I don't know for sure the height of the card and if it's low-profile enough that it would fit in the new server. There is not much of a technical resource onsite and the old server is in-use anyway so I would like to avoid making a trip in myself or trying to have someone onsite pop open the case and tell me what card is there. It's running Windows Server 2003 - is there a way to tell from say Device Manager what make and model the SCSI card might be? Or any other system diagnostic program or something that would give me hardware info like that? Thanks for any info!

    Read the article

  • Mac Mini drive problems but SMART verified: bad hard drive or controller?

    - by Zac Thompson
    I have a 3-year-old Intel Mac Mini at home. About a month ago, it stopped booting from the hard drive (internal, SATA, 80GB). I tried booting from the Install Disc to repair the filesystem but Disk Utility was unable to do so ("invalid node structure"). I was also unable to use the hard drive in the Terminal from the Install Disc nor from an Ubuntu boot CD ("DRDY err"). I could see the contents of some directories, but others would give an error and I would get failures when trying to copy files. At this point I was sure the filesystem was hosed and I'd want to reformat at least. DiskWarrior was able to let me retrieve the data files I was interested in, which are now copied to an external hard drive, but it reported a high number of problems ("speed reduced by disk malfunction" count was over 2000) when in the process of trying to rebuild the directory for the drive. It also would not let me use the rebuilt directory to replace the one on the drive; it claimed the disk errors prevented recovery in this way. Under normal circumstances I would now assume that the drive itself was going bad: DiskWarrior's "disk malfunction" error above is supposed to imply hardware problems. My initial plan was to buy a replacement for the internal 2.5" drive. However: Disk Utility, command-line tools and DiskWarrior had reported all along that the SMART status of the drive was okay/Verified. So I'm now worried that the drive hardware is actually fine, and that the problems were due to a disk controller that has gone "bad" somehow. If this is the case, I'll probably just replace the whole computer. Any advice on how I can tell what is to blame? I don't have a lot of extra hardware sitting around, so I don't have the option of simply dropping the drive in another machine or popping another hard drive inside the Mini.

    Read the article

  • Will wear induced by turning computers off in the evening be offset by energy savings?

    - by sharptooth
    I'm asking this here because this is primarily a huge office scenario and administrators will more likely have the answer I'm looking for. Employees' desktop computers can be either left turned on for the whole night or switched off in the evening and turned back on in the morning. The latter will surely save energy. In the same time turning on and off is very harmful for the equipment - hardware often breaks specifically when turned on. Both energy and hardware replacements cost money. With energy it's quite obvious - you pay every month according to what your power meter shows. With hardware replacements it's worse - you need qualified stuff to quickly diagnose the problems and once something breaks the affected employee will have to wait for some time while his computer is fixed/replaced and the data is recovered. So the company has to choose between saving money on energy and saving money on computer maintaince and lost hours. Such decisions must be well though. Is there any detailed study of how turning computers off each evening affects their lifetime?

    Read the article

  • Rendering a frame is producing noise from speakers in Windows and Linux

    - by Robber
    When any hardware accelerated application is rendering a frame (or many of them) a very short noise is coming from my speakers. This can be a game, a WebGL application or XBMC. When the application/game is rendering many frames per second (like most of them do) the noise is a continuous buzzing that gets higher pitched with higher framerates. This applies to Linux and Windows, so I'd assume it's a hardware problem. The current hardware in the PC is: CPU: Core2Quad Q9550 GPU: Radeon HD 5770 RAM: 2x2GB DDR2 Motherboard: Asus P5QLD PRO PSU: be quiet! Pure Power 530W Screen and speakers: Old 720p LCD TV connected via VGA and aux cable Muting the TV stops the noise, muting Windows doesn't. I tried replacing the PSU first (used a Tagan 700W PSU before) because I thought it was a power problem. It wasn't. I tried replacing the motherboard (used a ASUS P5B SE before) next because I thought it was a sound card problem. It wasn't. I tried the GPU in a different PC because I thought it was a broken graphics card. It worked perfectly fine in the other PC. I thought it might be interference, but moving the audio cable around changes absolutely nothing. I tried using an HDMI cable instead and that did work, but is not an option since my TV has only one HDMI input and I need that for my PS3.

    Read the article

  • Oracle: 1 Large Server vs. 2 Smaller Servers?

    - by nvahalik
    We are in the planning stages of setting up our production Oracle 10gR2 environment. Our budget gives us the ability to buy 2 processor licenses of Oracle DB Standard Edition. We have minimal experience with Oracle so I'll defer to anyone who has used it. We are trying to decide if we should set up a single dual quad-core box or 2 individual quad-core boxes in a RAC configuration. Our DB right now is about 60 GB, and at our peak, we'll have up to 150 concurrent users. Most of the big stuff is done via batch processing at night. My gut tells me that having 2 boxes in a RAC configuration can't be a bad thing because it provides a true hardware failover solution. DB stored in a shared LUN on a SAN via iSCSI. Plus if we ever need to add capacity, we already have boxes in place that can be upgraded with extra procs (I assume with zero downtime, since it's set up in a RAC config) if we add extra licenses, or RAM. Does RAC have any performance penalties? Will it add extra latency? Is there any true advantage for having dual processor boxes running these systems? If we build out the Oracle boxes with special hardware: hardware iSCSI cards, TOE NICs, will these boxes be solid? We are deploying on 64-bit Windows. So what would you do? One box or two?

    Read the article

  • Dell Poweredge R410 replace PERC S100 with PERC 6i

    - by Robe Eleckers
    I want to replace the PERC S100 RAID Controller with a PERC6i to be able to use 4 SAS harddrives instead of only SATA drives. What exactly do I need for this, what I've got so far: PERC6i PCIe x8 card. 4 x SAS 300GB 15000rpm drives Some questions I have Do I need a different backplane to accomodate the SAS disks? If so, what kind of backplane? Do I need a special cable to hookup the PERC6i with the backplane? If so, what kind of cable? Thanks.

    Read the article

  • Hardware for 4 Monitors

    - by Simon
    Looking to build several systems to output to 4 monitors over DVI. I notice most of the recent Nvidia and ATI/AMD cards have dual-DVI ports. Can I simply install two of these cards to get four monitors - or are only some cards capable of running side-by-side with another? How can I tell before purchasing? Simon.

    Read the article

  • RAIDZ vs RAID1+0

    - by Hiro2k
    Hi guys I just got 4 SSDs for my FreeNAS box. This server is only used to serve a single iSCSI extent to my Citrix XenServer pool and was wondering if I should setup them up in a RAIDZ or a RAID 1+0 configuration. This isn't used for anything in production, just for my test lab so I'm not sure which one is going to be better in this scenario. Will I see a major difference in speed or reliability? Currently the server has three 500GB Western Digital Blue drives and it's dog slow when I deploy a new version of our software on it, hence the upgrade.

    Read the article

< Previous Page | 61 62 63 64 65 66 67 68 69 70 71 72  | Next Page >