Search Results

Search found 19018 results on 761 pages for 'indicator network'.

Page 662/761 | < Previous Page | 658 659 660 661 662 663 664 665 666 667 668 669  | Next Page >

  • Suggestions for accessing SQL Server from internet

    - by Ian Boyd
    i need to be able to access a customer's SQL Server, and ideally their entire LAN, remotely. They have a firewall/router, but the guy responsible for it is unwilling to open ports for SQL Server, and is unable to support PPTP forwarding. The admin did open VNC, on a non-stanrdard port, but since they have a dynamic IP it is difficult to find them all the time. In the past i have created a VPN connection that connects back to our network. But that didn't work so well, since when i need access i have to ask the computer-phobic users to double-click the icon and press Connect i did try creating a scheduled task that attempts to keep the VPN connection back to our office up at all times by running: >rasdial "vpn to me" But after a few months the VPN connection went insane, and thought it was both, and neither, connected an disconnected; and the vpn connection wouldn't work again until the server was rebooted. Can anyone think of a way where i can access the customer's LAN that doesn't involve opening ports on the router needing to know their external IP customer interaction of any kind Blah blah blah use vpn vnc protocol has known weaknesses you are unwise to lower your defenses it's not wise to expose SQL Server directly to the internet you stole that line from Empire Customer doesn't care about any of that. Customer wants things to work.

    Read the article

  • Unable to ping domain.local, but can ping server.domain.local

    - by Force Flow
    I have a single windows 2008 server running active directory, group policy, and DNS. DHCP is running from the firewall (this is because there are multiple branch locations, and each location has its own firewall supplying DHCP. But, for this problem, the server and workstation are at the same location). On an XP workstation, if I try to visit \\domain.local or ping domain.local, the workstation can't find it. A ping returns Ping request could not find host domain.local. If I try to visit \\server or \\server.domain.local or ping server or server.domain.local, I'm able to connect normally. If I ping or visit domain.local on the server, I'm able to connect normally. A-Records are in place in the DNS service for server, domain.local, and server.domain.local. A reverse lookup zone also is enabled and PTR records are in place. If I wait 20-30 minutes, I am eventually able to ping and visit domain.local--but, when attempting to ping, it takes 30 second to return an IP address. I am also unable to join a new workstation to the domain during this wait period. If I try, the error message returned is "network path not found". Is there something I'm missing?

    Read the article

  • Homegroup should be working, but doesn't

    - by Tim
    I have Win7 installed on both my PC and laptop. When I choose to make a homegroup I can go through the steps of creating, getting password, then joining it from the other computer and it says that it all connects properly. But when I go to the homegroup tab it always says no other computers connected. If I look in the settings it will say "connected to suchandsuch homegroup" but the comps won't show. Also, on my PC, when I tick the boxes in the homegroup settings on what libraries I want to share, then click on save settings, it shuts down the settings window and when I re-open it the library tick boxes are all unticked again. Yet, I have had no problems with the tick boxes stayin ticked on the laptop. I have tried cancelling and remaking the homegroup, have tried making it on both computers, and have tried disabling and re-enabling the network connectors but it still won't work. At my old house we had 3 PCs running win 7 and 2 of them could homegroup together fine but mine never could as it was getting the same problem I am getting now. I feel like I am the only one on the planet with this problem. Can anybody help?

    Read the article

  • Reduce power consumption of gaming computer while idle

    - by White Phoenix
    This is my current build: EVGA X58 (first generation) motherboard Intel i7 965 clocked @ 3.3 Ghz 3x DDR3-1600 Corsair RAM at stock timings and voltages Corsair AX750 80 Plus Gold PSU 1 Optical Drive 1 Seagate 7200.10 500 GB drive 2x Western Digital Caviar Black 1 TB drives OCZ Vertex 1 60 GB EVGA GTX 460 oc'd at 800/1600/1850 Antec 1200 case HT-Omega Striker 7.1 Sound Card Windows 7 32-bit Professional (PAE Enabled) I've already seen this post Reduce power use on computer and this post How do I lower power consumption of my computer and while useful, I'm looking for answers specific to my build and OS. I'm pretty sure this build is a energy-intensive build by default, but I want to try to reduce the amount of energy my build uses when I leave it idle (when I go to bed or go out, etc). The first requirement for this machine is that I need to leave it on, so I cannot turn it off while it's being unused. I run it as a file server for personal reasons and I also leave it on in case people leave me messages on various IM services and chat clients (IRC, MSN, Steam, XFire, Pidgin, etc). I'm also unable to replace the parts in my computer with a cheaper "greener" part. What are some ways to minimize the amount of power the machine uses? I'm already using a high efficiency power supply (80 Plus Gold), but I imagine there's other things that can be done in the BIOS and Windows' power settings to reduce power usage while I'm not using the computer. From what I can tell, I can't use Sleep since that'll disable network access (whole reason why I leave the computer on in the first place). I already turn off my monitor when it's not in use. I enabled Intel SpeedStep within the BIOS (I know, I have a 965 and why am I enabling SpeedStep?) Should I bring the graphics card back to stock speeds and lower the clock on the processor even more? Main reason why I'm asking is I think this computer alone is the reason why my power bill is high, so I want to reduce its consumption to as low as possible without having to shut the thing down.

    Read the article

  • Iptables Forwarding problem

    - by ankit
    Hi all, I had initally asked question about sertting up my linux box for natting for my home network and was given suggestions in the thread here. Did not want to clutter the old question so starting a new one here. based on the earlier suggestions, i have come up with the following rules ... :PREROUTING ACCEPT [1:48] :OUTPUT ACCEPT [12:860] :POSTROUTING ACCEPT [3:228] -A POSTROUTING -o eth0 -j MASQUERADE COMMIT *filter :INPUT DROP [3:228] :FORWARD DROP [0:0] :OUTPUT DROP [0:0] -A INPUT -i lo -j ACCEPT -A INPUT -i eth0 -p icmp -j ACCEPT -A INPUT -i eth0 -p tcp -m tcp --dport 80 -j ACCEPT -A INPUT -i eth0 -p tcp -m tcp --dport 443 -j ACCEPT -A INPUT -i eth0 -p tcp -m tcp --dport 22 -j ACCEPT -A FORWARD -i eth1 -p icmp -j ACCEPT -A FORWARD -i eth1 -p tcp -m tcp --dport 80 -j ACCEPT -A FORWARD -i eth1 -p tcp -m tcp --dport 443 -j ACCEPT -A OUTPUT -p icmp -j ACCEPT -A OUTPUT -j ACCEPT COMMIT If you notice, i do have the proper MASQURADING rule and the proper FORWARD filter rule as well. However i am facing 2 problems On the linux box itself DNS resolving is not working the lan clients connected to the linux box, are still not able to get to internet. when i ping something from them, i see the DROP count in iptables INPUT rule increasing. now my question is, when i am pinging something from the lan client, how come it is being matched by the input chain ?! should it be in the forward chain ? Chain INPUT (policy DROP 20 packets, 2314 bytes) pkts bytes target prot opt in out source destination 99 9891 ACCEPT all -- lo any anywhere anywhere 0 0 ACCEPT icmp -- eth0 any anywhere anywhere 0 0 ACCEPT tcp -- eth0 any anywhere anywhere tcp dpt:http 0 0 ACCEPT tcp -- eth0 any anywhere anywhere tcp dpt:https 122 9092 ACCEPT tcp -- eth0 any anywhere anywhere tcp dpt:ssh Thanks ankit

    Read the article

  • Force local IP traffic to an external interface

    - by calandoa
    I have a machine with several interfaces that I can configure as I want, for instance: eth1: 192.168.1.1 eth2: 192.168.2.2 I would like to forward all the traffic sent to one of these local addresses through the other interface. For instance, all requests to an iperf, ftp, http server at 192.168.1.1 should be not just routed internally, but forwarded through eth2 (and the external network will take care of re-routing the packet to eth1). I tried and looked at several commands, like iptables, ip route, etc... but nothing worked. The closest behavior I could get was done with: ip route change to 192.168.1.1/24 dev eth2 which send all 192.168.1.x on eth2, except for 192.168.1.1 which is still routed internally. May be I could then do NAT forwarding of all traffic directed to fake 192.168.1.2 on eth1, rerouted to 192.168.1.1 internally? I am actually struggling with iptables, but it is too tough for me. The goal of this setup is to do interface driver testing without using two PCs. I am using Linux, but if you know how to do that with Windows, I'll buy it!

    Read the article

  • Why do I often have to refresh pages I navigate to once for them (or content in them) to load?

    - by GetOutOfBox
    I have noticed a bizarre pattern when using my PC, that when I open a link to a website, it often will often take a very long time to load, or time out. Sometimes content on the website will be drawn, but again, it seems to get "stuck" for an unusual amount of time before finishing. Most affected is Youtube; almost every time I navigate to a youtube video from another website such as Google, the video will not begin playing, but will instead just display the player controls with a black screen where the video should be and the buffering symbol, usually before displaying an error such as "The video failed to load". The unusual part of this problem is that whenever this happens, refreshing the page always causes it to load almost immediately the second time around, without any problems. Note that I'm not talking about how some browsers will dump whatever has been cached to the "pallet" briefly when the page is refreshed or loading stopped; but that the second time loading the website being faster. I have done my best to rule out some of the obvious causes: My Windows 7 desktop computer is the only device that seems to be affected. I use Firefox on it (latest version, flash updated, etc). My connection has more than enough bandwidth (30 megabits down, 4 up), and I've even tried QoSing all other devices to make sure this isn't happening due to usage spikes. Wireshark is not showing any clearly unusual network activity (i.e frequently dropped packets).

    Read the article

  • Apache2 slow serving static while healthy

    - by user45339
    My Apache status looks like; 201 requests/sec - 98.8 kB/second - 504 B/request 85 requests currently being processed, 345 idle workers _____CCW_C_____C__C__C_R____C_WC_________C__C____CW__C__CCC_____ __C____W______C___C___CW__C_C______C__W_C__C_____CCC____C______R CC_C_______C___C____C______________C______C__C________________C_ ___________________C______________________C_______C___C_____C___ CC____C__C___R_____C_C_CC__________C___C___________R____C_C_C___ ______C______W_W__W___C____________________C__WCC__R__R_C_______ R__RC________________________C___R____W__C____.................. .................................................... Server load is average 2 on a 4 core machine. IO utilization is 10-15% and doesn't have many jumps over 70%. Machine has almost 4 gb free and uses 0 swap. The site on the machine is a PHP site. All PHP code is optimized and fast mostly when it gets accessed, however sometimes requests get stuck. Stuck meaning; no response for at least 10 sec. We debugged the PHP code, but it is quite optimal and fast. We spend a lot of time on it until we decided to test the requesting of: <html><body>test</body></html> test.html page. This static resource also gets 'stuck' in the same manner the php pages get 'stuck'. How is the possible given the health of the system? I tested the network, but, when the PHP shows 'slowness' in the site monitoring, the html test files also take (far longer) than 10 sec to load using; time lynx -dump http://127.0.0.1/test.html We are kind of desperate to solve this problem, but we cannot seem to tackle it.

    Read the article

  • windows clients cannot get dns resolution until you open and close ipv4 properties page

    - by GC78
    This strange problem has started recently. Some windows clients cannot seem to get dns resolution to the internet after boot, and sometimes again at some point in the day. Internal hosts are also slow to resolve. trying to ping an interal host by name will take a long time for the hostname to resolve to ip address and trying to ping a website by name will fail to resolve. If you go into the tcp/ip v4 properties and view but not change anything, ok/close out of that then the client starts working fine, hostnames will resolve quickly. I have seen this happen on both Vista and W7 clients. ipconfig /all at a client experiencing this problem shows everything in order. proper ip addr, gateway, dns server, dns suffix ect.. ipconfig /dnsflush will not fix them, neither will /release and /renew the clients get their ip address, mask and dns server info from either one of 2 OES dhcp servers that assign addresses in different scopes in the same subnet. the internal dns server is a different OES dns server the default gateway is not assigned by the OES server but is statically put in at the client (only for those who need to get to the Internet for their job) flat network topology What can I do to get to the bottom of this? It only happens to a few of the client machines and typically the same ones. It started happening when we made a change to one of the DHCP scopes in iManager. Strangly this problem only happens to clients that get an IP address from the scope that we didn't make any changes to.

    Read the article

  • Unix Permissions: Enable access to files no matter the user?

    - by TK Kocheran
    I've been using Linux for a long time and I still am completely in the dark about how file permissions really work. With that in mind, does anyone have any books or thorough guides I could read to really understand things completely? I've done my fair share of sysadminning, so I know the easy stuff like making directories readable and writable, making files executable, and changing the owner of a file, but on sharing files across users, I'm lost. Here's my main problem. I have a number of machines across which I intend to synchronize my music library. I've been using Unison for a while now and it's a great choice as I can easily run it over SSH on my local network which I just set up. Win-win. Up until this point, I've been synchronizing computers using a 2TB external hard drive. (computer 1 unisons to HD, computer 2 unisons to HD, etc.) This is tedious at best, especially since I encrypted the drive, making it a huge hassle to hook it up to all of my machines and sync it. Anyway, the drive is running ext4 (in TrueCrypt), so it maintains all Unix filesystem info like owners and groups. I just set up a new machine and just Unison'd it to get the music on it, and I realized that now, all of my permissions are fubar. I had to run Unison as root since that was the only way I could get the files to come off of the external drive. Apparently, since I'm using a different user name on this machine than my usual "rfkrocktk" across all machines, this essentially throws a huge wrench in the gears. Here's my use case. This laptop has two effective users, "leandra" and "rfkrocktk". I want to share music between these two users, so I symlinked /home/rfkrocktk/Music to point to /home/leandra/Music. How do I (a) allow both users access to read/write/delete files in this folder, and (b) keep everything nicely in sync without messing up file ownership?

    Read the article

  • PFSense VPN Routing

    - by SvrGuy
    We use PFSense firewalls at three installations with the following LAN networks: 1.) Datacenter #1: 10.0.0.0/16 2.) Datacenter #2: 10.1.0.0/16 3.) HQ: 10.2.0.0/16 All of these locations are linked via an IPSEC tunnel that works properly. Hosts in any of the above networks can communicate with hosts in any other of the above networks. Now, for our laptops etc. we established a road warrior network 10.3.0.0/16 and have implemented OpenVPN to link the laptops etc. to Datacenter #1. This works great too, so our laptops can connect and communicate with any host in Datacenter #1 (anything on 10.0.0.0/16) The problem is the laptops can't communicate with any hosts that Datacenter #1 can reach by its IPSEC tunnel to Datacenter #2 (and/or the HQ for that matter). Does anyone know what to do configuration wise on the PFSense box in Datacenter #1 to configure to route packets received on the OpenVPN tunnel to Datacenter #2 over the IPSEC tunnel? It could be a setting on the OpenVPN or some sort of static route or some such. Any ideas?

    Read the article

  • Migrating from tomcat to tc server - receiving java.sql.SQLException on startup

    - by user470184
    I'm receiving below error when I start tcServer. I do not receive this error on standalone version of tomcat. Is there extra config I need to add for tcServer ? WARNING: Unexpected exception resolving reference java.sql.SQLException: Io exception: The Network Adapter could not establish the connection at oracle.jdbc.driver.DatabaseError.throwSqlException(DatabaseError.java:112) at oracle.jdbc.driver.DatabaseError.throwSqlException(DatabaseError.java:146) at oracle.jdbc.driver.DatabaseError.throwSqlException(DatabaseError.java:255) at oracle.jdbc.driver.T4CConnection.logon(T4CConnection.java:387) at oracle.jdbc.driver.PhysicalConnection.(PhysicalConnection.java:441) at oracle.jdbc.driver.T4CConnection.(T4CConnection.java:165) at oracle.jdbc.driver.T4CDriverExtension.getConnection(T4CDriverExtension.java:35) at oracle.jdbc.driver.OracleDriver.connect(OracleDriver.java:801) at org.apache.tomcat.jdbc.pool.PooledConnection.connectUsingDriver(PooledConnection.java:277) at org.apache.tomcat.jdbc.pool.PooledConnection.connect(PooledConnection.java:182) at org.apache.tomcat.jdbc.pool.ConnectionPool.createConnection(ConnectionPool.java:699) at org.apache.tomcat.jdbc.pool.ConnectionPool.borrowConnection(ConnectionPool.java:631) at org.apache.tomcat.jdbc.pool.ConnectionPool.init(ConnectionPool.java:485) at org.apache.tomcat.jdbc.pool.ConnectionPool.(ConnectionPool.java:143) at org.apache.tomcat.jdbc.pool.DataSourceProxy.pCreatePool(DataSourceProxy.java:116) at org.apache.tomcat.jdbc.pool.DataSourceProxy.createPool(DataSourceProxy.java:103) at org.apache.tomcat.jdbc.pool.DataSourceFactory.createDataSource(DataSourceFactory.java:539) at org.apache.tomcat.jdbc.pool.DataSourceFactory.getObjectInstance(DataSourceFactory.java:237) at org.apache.naming.factory.ResourceFactory.getObjectInstance(ResourceFactory.java:140) at javax.naming.spi.NamingManager.getObjectInstance(NamingManager.java:304) at org.apache.naming.NamingContext.lookup(NamingContext.java:793) at org.apache.naming.NamingContext.lookup(NamingContext.java:140) at org.apache.naming.NamingContext.lookup(NamingContext.java:781) at org.apache.naming.NamingContext.lookup(NamingContext.java:153) at org.apache.catalina.core.NamingContextListener.addResource(NamingContextListener.java:1028) at org.apache.catalina.core.NamingContextListener.createNamingContext(NamingContextListener.java:637) at org.apache.catalina.core.NamingContextListener.lifecycleEvent(NamingContextListener.java:238) at org.apache.catalina.util.LifecycleSupport.fireLifecycleEvent(LifecycleSupport.java:142) at org.apache.catalina.core.StandardServer.start(StandardServer.java:747) at org.apache.catalina.startup.Catalina.start(Catalina.java:595) at sun.reflect.NativeMethodAccessorImpl.invoke0(Native Method) at sun.reflect.NativeMethodAccessorImpl.invoke(NativeMethodAccessorImpl.java:39) at sun.reflect.DelegatingMethodAccessorImpl.invoke(DelegatingMethodAccessorImpl.java:25) at java.lang.reflect.Method.invoke(Method.java:597) at org.apache.catalina.startup.Bootstrap.start(Bootstrap.java:289) at org.apache.catalina.startup.Bootstrap.main(Bootstrap.java:414)

    Read the article

  • can't backup to a NAS drive as offline schedule task

    - by imageng
    I have seen this problem issue discussed in several forums including this one, but could not find a solution. On MS server 2003 I configured a Backup task, the target backup is on a NAS disc (Seagate BlackArmor NAS 110). The backup task is working well as a scheduled task or by a direct command, when I am logged on. It is not working when the user is offline (in this case - Administrator). I already tried the following actions: 1) addressing to the target as network drive (Y:location..), 2)Using UNC instead, 3) making the drive a domain member (the NAS admin S/W allows to define itself as a domain member) The result log message for 1 and 2 is: "The operation was not performed because the specified media cannot be found." The result log message for 3 is empty file. The schedule task "RUN" command is: C:\WINDOWS\system32\ntbackup.exe backup "@C:\Documents and Settings\Administrator\Local Settings\Application Data\Microsoft\Windows NT\NTBackup\data\de-board.bks" /a /d "Set created 2/14/2010 at 5:10 PM" /v:yes /r:no /rs:no /hc:off /m incremental /j "de-board" /l:s /f "\10.0.0.8\public\Backups\IBMServer\de-board.bkf" 10.0.0.8 is the static IP of the NAS. "Run only if logged on" is NOT marked. Password of the administrator user is set. It is obvious that there is no access to the NAS when the user is logged-out. Do you have any idea how can I solve it? Thanks

    Read the article

  • Add IPv6 support to DirectAdmin server

    - by George Boot
    I just set up an new DirectAdmin, and I want to prepare it for IPv6 use. My ISP have gave me an range of IPv6 addresses that I can use. Lets say that address is 2a01:7c8:**:1f::. My neworkadapter user DHCP to resolves its IP-addresses. When i type ifoncig eth0 I get the following result: eth0 Link encap:Ethernet HWaddr 52:**:**:**:ce:f3 inet addr:37.**.**.44 Bcast:37.**.**.255 Mask:255.255.255.0 inet6 addr: 2a01:7c8:****:1f::/64 Scope:Global inet6 addr: fe80::5054:ff:fe87:cef3/64 Scope:Link UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1 RX packets:38941 errors:0 dropped:0 overruns:0 frame:0 TX packets:29439 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:1000 RX bytes:3779534 (3.6 MiB) TX bytes:5089379 (4.8 MiB) As you can see, I have an IPv6 address set, but I can't ping6 an IPv6 host. I get the error: connect: Network is unreachable. I decided that I needed an gateway, so I tryed to add one: ip -6 route add default via 2a01:7c8:****::1 dev eth0 (2a01:7c8:**::1 is the gateway of my ISP). But it trows an error: RTNETLINK answers: No route to host. Does somebody know what to do, and how to solve this issue? Thanks a lot!

    Read the article

  • Swap static public IPs without creating DNS conflicts?

    - by Jakobud
    Our ISP is Comcast and we have 5 static public IPs from them that we use for various services, including customers connecting to our network, VPN, web, DNS, etc... We need more IP addresses from Comcast. Unfortunately, Comcast is telling us that they can't just simply give us 5 more addresses. They only give static IP addresses in blocks of 1, 5 or 13. In order for us to get more static IPs, they have to take away our current 5 static IPs and give us 13 new ones. How do we make this transition without causing all sorts of DNS chaos? We run public DNS servers, so we can make the DNS changes ourselves, but it will take some time obviously for those DNS changes to propagate throughout the internet. Are there any easy ways to make this transition? Like create some type of fallback DNS entry or something? Surely there must be some sort of procedure for this kind of thing. The Comcast support guy was useless.

    Read the article

  • Long access time for static web page on virtual machine

    - by Karol
    My setup Windows 7 on workstation that I use at work (with domain) and home (no domain) Virtual machine (VMWare) that runs Arch Linux (I will call it just "Linux") with network interface in bridged mode. Linux serves web pages with Nginx. IP address of Linux machine is 192.168.0.16 and is added to C:\windows\system32\drivers\etc\hosts: 192.168.0.16 bridged bri IP address of Windows workstation is added to /etc/hosts: 192.168.0.10 workstation I can add more details to my setup description (I am not sure what is relevant). The question Often (but not always) it takes long time for a web browser (Firefox) to open static web page served by Linux. I am sure it is not a performance issue. To be more specific: it takes about ~20 seconds to resolve(?) the address http://bridged for a web browser. Additionally I have just installed samba service and noticed similar problem, so it is not specific to browser & http. Initial access for samba shares also takes long time.

    Read the article

  • Linux DHCPD Mac-Address based Groups

    - by GruffTech
    Our Current DHCPD.conf looks like the following. subnet 10.0.32.0 netmask 255.255.255.0 { range 10.0.32.100 10.0.32.254; option subnet-mask 255.255.255.0; option broadcast-address 10.0.32.255; option domain-name-servers 208.67.222.222,208.67.220.220; option routers 10.0.32.5; host Dev-ABaird-W { hardware ethernet 00:1D:09:3E:49:13; fixed-address 10.0.32.94; } ... more static hosts .... } About as basic as it gets. The old router is 10.0.32.1, our company wanted to implement a squid proxy to better monitor web traffic while at work, and if necessary block large time-wasters, IE Facebook.com. However, we've quickly realized that this change has played a mean prank on our Polycom SIP Phones. Occasionally our phones will not ring, the end recipient hears ringing (this is artificially created by our PBX) however the handset never rings. The ONLY thing that has changed in our network is the option routers line. So, Since all Polycom MAC addresses begin with 00:04:F2 would it be possible in DHCP to say any 00:04:F2:::* MAC addresses get option routers 10.0.32.1, and anything else must talk with our Gateway?

    Read the article

  • Error upgrading Ubuntu server from Intrepid to Jaunty

    - by Martin
    I'm trying to upgrade an old ubuntu server from 8.10 (Intrepid) to 9.04 (Jaunty). But it fails. root@server1:/# do-release-upgrade Checking for a new ubuntu release Failed Upgrade tool signature Failed Upgrade tool Done downloading extracting 'jaunty.tar.gz' Failed to extract Extracting the upgrade failed. There may be a problem with the network or with the server. Does anyone have an idea why I get this error and how to fix it? UPDATE: I think i might have tracked the problem down. My /etc/update-manager/meta-release looks like this: [METARELEASE] URI = http://changelogs.ubuntu.com/meta-release URI_LTS = http://changelogs.ubuntu.com/meta-release-lts URI_UNSTABLE_POSTFIX = -development URI_PROPOSED_POSTFIX = -proposed If i go to http://changelogs.ubuntu.com/meta-release it has this info for Jaunty: Dist: jaunty Name: Jaunty Jackalope Version: 9.04 Date: Thu, 23 Apr 2009 12:00:00 UTC Supported: 0 Description: This is the 9.04 release Release-File: http://archive.ubuntu.com/ubuntu/dists/jaunty/Release ReleaseNotes: http://changelogs.ubuntu.com/EOLReleaseAnnouncement UpgradeTool: http://archive.ubuntu.com/ubuntu/dists/jaunty-proposed/main/dist-upgrader-all/0.111.8/jaunty.tar.gz UpgradeToolSignature: http://archive.ubuntu.com/ubuntu/dists/jaunty-proposed/main/dist-upgrader-all/0.111.8/jaunty.tar.gz.gpg Those links starting with archive.ubuntu.com are broken since jaunty is EOL. I guess i could fix this by copying this file, replacing "archive" with "old-releases", host the modified file somewhere and change the url in the meta-release file. Is this a good solution or will it make me run into worse problems?

    Read the article

  • "Server Unavailable" and removed permissions on .NET sites after Windows Update [closed]

    - by andrewcameron
    Our company has five almost identical Windows 2003 servers with the same host, and all but one performed an automatic Windows Update last night without issue. The one that had problems, of course, was the one which hosts the majority of our sites. What the update appeared to do was cause the NETWORK user to stop having access to the .NET Framework 2.0 files, as the event log was complaining about not being able to open System.Web. This resulted in every .NET site on the server returning "Server Unavailable" as the App Domains failed to be initialise. I ran aspnet_regiis which didn't appear to fix the problem, so I ran FileMon which revealed that nobody but the Administrators group had access to any files in any of the website folders! After resetting the permissions, things appear to be fine. I was wondering if anyone had an idea of what could have caused this to go wrong? As I say, the four other servers updated without a problem. Are there any known issues involved with any of the following updates? My major suspect at the moment is the 3.5 update as all of the sites on the server are running in 3.5. Windows Server 2003 Update Rollup for ActiveX Killbits for Windows Server 2003 (KB960715) Windows Server 2003 Security Update for Internet Explorer 7 for Windows Server 2003 (KB960714) Windows Server 2003 Microsoft .NET Framework 3.5 Family Update (KB959209) x86 Windows Server 2003 Security Update for Windows Server 2003 (KB958687) Thanks for any light you can shed on this.

    Read the article

  • VPN issue: SSTP Service service started and then stopped

    - by Ampersand
    When I was trying to set up a VPN connect on my laptop running Windows 7 Ultimate, I got this error: Network Connections Cannot load the Remote Access Connection Manager service. Error 711: The operation could not finish because it could not start the Remote Access Connection Manager service in time. Please try the operation again. I traced through some service dependencies and discovered that Secure Socket Tunneling Protocol Service was set to Manual. However, when I try to manually start the service, I get: Services The Secure Socket Tunneling Protocol Service on Local Computer started and then stopped. Some services stop automatically if they are not in use by other services or programs. Setting all the services involved to Automatic did not help. SSTP just showed Automatic and Stopped in the Services panel. I found a solution that involved booting in Safe Mode and deleting the contents of C:\Windows\System32\LogFiles\WMI\RtBackup. This solution worked, and I could set up a vpn connection, but only until I rebooted again. TL;DR I'm looking for a way to permanently enable Secure Socket Tunneling Protocol Service and other vpn-related services permanently so I don't have to reboot into safe mode and delete files every time I need to connect to a vpn.

    Read the article

  • PC powers off at random times

    - by Timo Huovinen
    Short Version After experiencing some problems with Mobo batteries my PC started to power off at random times, the power off is instant and sudden and does not restart afterwards, need help figuring out the cause. Facts: Powers off when PC is playing games Powers off when PC is idle Powers off when PC is in safe mode Powers off when PC is in BIOS Powers off when PC is booted through a Windows installation USB Replaced the motherboard battery several times Replaced the 650W PSU with a 750W PSU Replaced the RAM Swapped the RAM between slots Re-applied thermal paste to the CPU Checked if the motherboard touches the case Nothing is overclocked PC Specs PC specs: OS: Windows 7 Ultimate SP1 RAM: klingston 1333MHz 4GB stick CPU: AMD Phenom II x4 955 Mobo: Gigabyte 88GMA-UD2H rev 2.2 Motherboard battery: CR2032 3v HDD: 500GB Seagate ST3500418AS ATA Device Graphics: ATI/AMD Radeon HD 6870 Very Long version Around 10 months ago I built a brand new gaming PC. Around 6 months ago it's time setting in windows started resetting to the year 2010. I swapped the Motherboard battery for a new one of the exact same size and shape and voltage, and the problems disappeared...for around 2 weeks. Then the same problem happened again, time gets reset, I swapped the battery again, and the problem was gone for good and everything was great for about 3 months.. then another problem started happening, the PC started to power off suddenly and without warning at completely random times, sometimes the PC works for and hour, sometimes 5 minutes. So I read on the forums that it might be either the PSU or the motherboard Battery or RAM or HDD or the Graphics card or the CPU or the motherboard or the drivers or a Virus or Grounding issues, or something short circuiting, basically it can be anything... I spent some days researching, and decided to remove the possibility of a virus. I reset the CMOS, cleared all BIOS settings and reinstalled windows 7 after a full format of the HDD, but the random power off kept happening. I then disabled the restart on error option in windows and looked at the event log for error events, but they did not help me figure out the problem. Network list service depends on network location awareness the dependency group failed to start Source Kernel Power Event 41 Task Category 63 Source Disk Event ID 11 Task Category None The driver detected a controller error on device disk I took apart the PC, every little piece, re-applied some expensive thermal paste to the CPU, and double checked that none of the pieces are touching the PC case. The problem was gone, the PC no longer powered off randomly I re-attached the graphics card and all was good for 4 months... then the power off problem appeared again, but was happening at high intervals, the PC would shutdown once in 2 days on average, at random points in time, sometimes when it's idle all day long, sometimes when it's running CRYSIS 2. I checked the CPU temperature, because I know that AMD CPU's have a built in protection mechanism that switches off the PC if the CPU gets too hot, and the Temp was 50C system temp, and 45C CPU after running the PC all day long (I did not do tests to see if there are any temperature spikes, don't know how to do them) Originally the PSU that powered the PC was 650Watts and had one 4 pin cable to power the CPU, I replaced it with a new 750Watts PSU which has two 4 pin cables for the CPU, but the problem remained. I removed the graphics card and let the motherboard use the built in one, but the PC kept suddenly powering off at random times. I took apart the PC completely again, and re-applied thermal paste to the CPU, added lots of insulation, and checked for any type of short-circuit possibility again and again, but the problem remained. The problem was like that for some months. I replaced the Battery a couple of times over the time, changed lots of options in windows, and tried everything I could, but it kept powering off, so I stopped using the PC as much as I used to, just living with the random power offs from time to time, until a couple of days ago, when the power off happens almost immediately after powering on the PC. I replaced the RAM with a brand new one, but that did not help. Took apart the PC again, checked for anything anywhere that might cause it, found some small scratches on the very edge of the motherboard to the left of the PCI express x16 slot. This might cause the problem, I thought, but the scratch looks very superficial, not deep at all, and if the scratch did harm the motherboard, wouldn't it cause it to not start at all? And why did it start to power off a while ago, and then suddenly stop powering off? The scratches could not have vanished??? did chkdsk \d but it powered off when it was at 75% I removed the hard disks, the graphics card, while I fiddled with the BIOS settings, and suddenly the PC shut down while I was looking at the BIOS version. This makes me realize, it is not caused by: HDD, Windows, Drivers or the Graphics card I cleared the CMOS again, updated the BIOS from F5 to F6f beta, but that did not help, it might even seem that the PC powers off even sooner. The shutdown even happened to me while I booted through a windows 7 installation USB and was in the repair console. I removed one of the cables powering the CPU, now only one 4pin cable powers it, and it worked for 30mins after doing that, which makes me think that it's the CPU overheating, and because it gets less power, it overheats slower? The things that I am still considering: CPU overheating (does not seem to overheat, maybe false readings?) Motherboard short circuiting (faulty motherboard?) I desperately need some advice in what is faulty, is it a faulty Motherboard or an overheating CPU? or maybe something else? I have been breaking my head over this problem over a span of 6 months. I'm not sure if this is a good place to ask this question, if it is not, then tell me where I can get some experienced help. More info I have also discovered a mysterious piece that seems to have fallen out of the motherboard i119.photobucket.com/albums/o126/yurikolovsky/strangepiece.jpg What is it? Looks like each time that it powers off the datetime gets reset I also found another forum post tomshardware.co.uk/forum/… except I don't have Integrated PeripheralsUSB Keyboard Function option in BIOS :S Comments summary (asked by Random moderator) Q. tell me, if the computer restarts, is it immediately? Does it take a second and then restarts? Do you see (BSOD) or hear (PSU, short circuit) any suspicious when it happens? After reading trough it, it remains the mainboard that is faulty. – JohannesM A. Immediate power off, all the fans stop instantly, all the light turn off instantly, no sound or anything, and it remains off until I turn it back on. Thanks for the feedback, faulty motherboard is what I fear. Q. Try stress-testing the system with Prime95 and see if errors or shutdowns occur when the CPU is under full load. – speakr A. Prime95 heat stress test peaked CPU heat at 60C after 5mins, it powered off after 30mins of testing in the middle of the test with no errors, Prime95 Heat test or the stress-testing with low RAM usage (small or in-place FFTs) do not report errors while testing for 10-60 mins. The power off does not seem like it is affected by Prime95 at all Makes me wonder if it's a CPU or Motherboard issue at all. Q. I had similar random/intermittent problems with my old board. It gave one of a few different symptoms: keyboard and/or mouse would die and/or the RAM wouldn't work and/or it would shut down. It was in bad shape. One problems was that my old PSU had literally burned the connector on it (browned around the pins), another was that a broken lead inside the layers of the PCB would work sometimes if it happened to be hot or if I bent the board—by jamming a hunk of wood behind it. I managed to keep the board alive for several years, but eventually nothing I did would make it work correctly anymore. – Synetech A. I will try that as the last resort, ok? ;) Q. Have you tried a different power cord, surge protector, outlet (on a different circuit). It's worth a shot just to ensure it's not subpar wiring or a week circuit (dips in power may cause shutdown if the PSU can't pull enough juice from the wall). – Kyle A. yes, I attached the PC to an entirely different outlet on a different circuit and the problem persists. After connecting it to a different outlet after starting the PC it gave me 3 long beeps and 1 short one, then the PC immediately proceeded to boot up normally. Q. Re-check your mainboard manual and all PSU connections to your mainboard to be sure that nothing is missing (e.g. 12V ATX 4-pin/6-pin connector). If you can provoke shutdowns with Prime95, then consider buying new hardware -- a stable system should run Prime95 for 24h without any errors. Prime95 mentions errors in the log when they occur and gives a summary after the stress test was stopped manually (e.g. "0 errors, 0 warnings", if all is fine) – speakr A. Re-checked, there are no more PSU connectors that I can physically connect, except the one ATX 4-pin (there are 2 that power the CPU) that I disconnected on purpose, I have reconnected it but the problem persists. Q. With one PC I had a short curcuit. The power button on the front plate had its cables soldered, but not isolated, and the contacts were very close to the metal case. A heavier touch was enough to cause a shutdown. The PC's vibration could be enough – ott-- A. yes, it seems to switch off with even the lightest touch, I switched on the PC, then pulled out the front panel power cable that connects to the motherboard so the power button does not work anymore, after 5 mins of working like that, with the power button completely disconnected, just sitting idle, the PC powered off again, I don't think it's the power button. Q. I wonder if you dare to operate components without the case, that is remove motherboard, power, disk ( just put the motherboard on a wooden desk). Don't bend the adapters when running like that. – ott-- A. yes, I do dare to do that, but only tomorrow, too tired/late right now.

    Read the article

  • NTDS Replication Warning (Event ID 2089)

    - by Chris_K
    I have a simple little network with 3 AD servers in 2 sites. Site A has Win2k3 SP2 and Win2k SP4 servers, site B has a single Win2k3 SP2 server. All have been in place for at least 3 years now. Just last week I started getting Event 2089 "not backed up" warnings (example below) on both of the win2k3 servers. I understand what the message means, no need to send me links to the technet article explaining it. I'll improve my backups. What I'm more curious about is why did I just start getting this message now? Why haven't I been getting it for the past 3 years?!? Perhaps this is related: I recently decommissioned a few other sites and AD controllers (there used to be 3 more sites, each with their own controller). Don't worry, I did proper DCpromo exercises and made sure we didn't lose anything. But would shutting those down possibly be related to why I get this error now? This won't keep me awake at night but I am curious as to what changed... Event Type: Warning Event Source: NTDS Replication Event Category: Backup Event ID: 2089 Date: 3/28/2010 Time: 9:25:27 AM User: NT AUTHORITY\ANONYMOUS LOGON Computer: RedactedName Description: This directory partition has not been backed up since at least the following number of days. Directory partition: DC=MyDomain,DC=com 'Backup latency interval' (days): 30 It is recommended that you take a backup as often as possible to recover from accidental loss of data. However if you haven't taken a backup since at least the 'backup latency interval' number of days, this message will be logged every day until a backup is taken. You can take a backup of any replica that holds this partition. By default the 'Backup latency interval' is set to half the 'Tombstone Lifetime Interval'. If you want to change the default 'Backup latency interval', you could do so by adding the following registry key. 'Backup latency interval' (days) registry key: System\CurrentControlSet\Services\NTDS\Parameters\Backup Latency Threshold (days) For more information, see Help and Support Center at http://go.microsoft.com/fwlink/events.asp.

    Read the article

  • Migrateing to Windows Server 2008 R2 Domain Controllers - a few Questions/Issues

    - by Chris
    Ok so here's our setup: We have 2 Windows2k3 Domain Controllers. I am trying to replace them with Windows 2008 R2. The Win2k3 servers are DC01 and DC02. The Windows2k8 servers are DC1 and DC2. I prepared the Windows Server 2003 Forest Schema for a Domain Controller That Runs Windows Server 2008 or Windows Server 2008 R2. Then with both of the new servers up as member servers I dcpromo'd DC1 using the advanced option and added it successfully to my exisiting domain. Roles are GC, DNS and Active Directory Domain Services.I transferred The PDC, RID pool manager and Infrastructure master FSMO to the new DC.(DC1) The Schema master and Domain naming master are still on the old DC (DC01). The first issue I'm encountering is when i dcpromo the second DC (DC2) and select "Replicate data over the network from and existing domain controller" I select the new DC to replicate from (DC1) I get the following error: "Failed to identify the requested replica partner (dc1.xxx.org) as a valid domain controller with a machine account for (DC2$). This is likely due to either the machine account not being replicated to this domain controller because of replication latency or the domain controller not advertising the Active Directory Domain Services. Please consider retrying the operation with \dc01.xxx.org as the replica partner. "The server is unwilling to process the request." Is this because the Schema master and Domain naming master roles are still on the old DC (DC01)? And if so, if I transfer Schema master and Domain naming master roles to DC1 what is the risk or breaking my AD? I'm a little paranoid because this process HAS to be transparent. ANY down time or interruption will result in me getting a verbal ass kicking from my I.T. Director. Both of the new servers DNS point the the old DNS servers (DC01 and DC02) not themselves by the way. Thanks in Advance -Chris

    Read the article

  • In spite of correct DNS, Exchange sending to wrong destination server for single outbound domain

    - by beporter
    My company uses an SBS 2003 server and makes use of Exchange to host our own email. We also have a linux server hosting domains for some of our clients. In order for us to send to those clients, we had internal DNS set up to shadow the client domains to provide "correct" MX records inside our network. For example, public DNS for a domain abc.com might point to 1.2.3.4, but internally we have MX records set up to route mail for abc.com to 172.16.0.4, which is the linux email server. This setup was entirely functional; this is just back story. We've recently moved one of our client domains from our internal linux server to an external email provider. When we did that, we naturally deleted our internal shadow DNS records so our Exchange server would fetch correct (public) DNS records and route mail out to the new external host. This has NOT had any effect on Exchange though. Even after rebooting the Exchange server and completely flushing the DNS cache (nslookups on the Exchange machine itself correctly resolve to the new external address) Exchange still attempts to deliver messages for the domain to our internal server! Exchange correctly routes to all other internal and external domains when sending email. Somehow Exchange is trying to deliver to a machine that by all accounts it has no business trying to use for just this one domain. Is there a DNS cache that Exchange uses internally? Is there a way to flush that internal cache? What else could I be missing?

    Read the article

  • Durability of Websockets Server

    - by smitchell360
    I am starting to experiment with websockets. Does anyone know of a websockets server (open source or paid) that provides a durable store of the websocket "channel"? All of the examples that I have found do not address durability -- if a websockets server goes down, all "channel" data is lost. Services such as Pusher do not really discuss whether they address the durability issue (and I have not received a response from tech support yet). Happy to roll my own, but would rather not reinvent the wheel. EDIT: I'm not looking for websockets 101 information. That is readily available and understood. I'm looking for a server (open source or paid) that supports websockets and has a durable store for the websocket data so that, in the event that a server fails, a new server can take over where the original one left off. Two main purposes: 1. support failover scenarios contemplated by the websockets Network Working Group http://tools.ietf.org/html/draft-ibc-websocket-dns-srv-02#section-5.1 (most importantly so that missed messages are sent when a client connects to a failover server) 2. support scenarios where new subscribers must receive all past messages that were published. Of course this can be handled at the application layer...but that is not what I am looking for.

    Read the article

< Previous Page | 658 659 660 661 662 663 664 665 666 667 668 669  | Next Page >