Search Results

Search found 84911 results on 3397 pages for 'data access layer'.

Page 67/3397 | < Previous Page | 63 64 65 66 67 68 69 70 71 72 73 74  | Next Page >

  • Evaluating Oracle Data Mining Has Never Been Easier - Evaluation "Kit" Available

    - by chberger
    Normal 0 false false false EN-US X-NONE X-NONE MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin-top:0in; mso-para-margin-right:0in; mso-para-margin-bottom:10.0pt; mso-para-margin-left:0in; line-height:115%; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri","sans-serif"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin; mso-bidi-font-family:"Times New Roman"; mso-bidi-theme-font:minor-bidi;} Now you can quickly and easily get set up to starting using Oracle Data Mining for evaluation purposes. Just go to the Oracle Technology Network (OTN) and follow these simple steps. Oracle Data Mining Evaluation "Kit" Instructions Step 1: Download and Install the Oracle Database 11g Release 2 Anyone can download and install the Oracle Database for free for evaluation purposes. Read OTN web site for details. 11.2.0.1.0 DB is the minimum, 11.2.0.2 is better and naturally 11.2.0.3 is best if you are a current customer and on active support. Either 32-bit or 64-bit is fine. 4GB of RAM or more works fine for SQL Developer and the Oracle Data Miner GUI extension. Downloading the database and installing it should take just about an hour or so, depending on your network and computer. For more instructions on setting up Oracle Data Mining see: http://www.oracle.com/technetwork/database/options/odm/dataminerworkflow-168677.html When you install the Oracle Database, the Sample Examples data should also be installed e.g.:Release 2 Examples win32_11gR2_examples.zip (565,154,740 bytes). Contains examples of how to use the Oracle Database. Download if you are new to Oracle and want to try some of the examples presented in the Documentation Step 2: Install SQL Developer 3.1 (the Oracle Data Mining Extension installs automatically) Step 3. Follow the four free step-by-step Oracle-by-Examples e-training lessons: Setting Up Oracle Data Miner 11g Release 2 This tutorial covers the process of setting up Oracle Data Miner 11g Release 2 for use within Oracle SQL Developer 3.0. Using Oracle Data Miner 11g Release 2 This tutorial covers the use of Oracle Data Miner to perform data mining against Oracle Database 11g Release 2. In this lesson, you examine and solve a data mining business problem by using the Oracle Data Miner graphical user interface (GUI). Star Schema Mining Using Oracle Data Miner This tutorial covers the use of Oracle Data Miner to perform star schema mining against Oracle Database 11g Release 2. Text Mining Using Oracle Data Miner This tutorial covers the use of Oracle Data Miner to perform text mining against Oracle Database 11g Release 2. That’s it! Easy, fun and the fastest way to get started evaluating Oracle Data Mining. Enjoy! Charlie

    Read the article

  • unknown data encoding

    - by Keyur Shah
    Hi, While i was working with an old application with existing database which is in ms-access contains some strange data encoding such as 48001700030E0F465075465A56525E1100121D04121B565A58 as email address What kind of data encoding is this? i tried base64 but it dosent seems that. Can anybody with previous experience with ms-access could tell me what possible encoding could this be.

    Read the article

  • access exception when invoking method of an anonymous class using java reflection

    - by Asaf David
    Hello I'm trying to use an event dispatcher to allow a model to notify subscribed listeners when it changes. the event dispatcher receives a handler class and a method name to call during dispatch. the presenter subscribes to the model changes and provide a Handler implementation to be called on changes. Here's the code (I'm sorry it's a bit long). EventDispacther: package utils; public class EventDispatcher<T> { List<T> listeners; private String methodName; public EventDispatcher(String methodName) { listeners = new ArrayList<T>(); this.methodName = methodName; } public void add(T listener) { listeners.add(listener); } public void dispatch() { for (T listener : listeners) { try { Method method = listener.getClass().getMethod(methodName); method.invoke(listener); } catch (Exception e) { System.out.println(e.getMessage()); } } } } Model: package model; public class Model { private EventDispatcher<ModelChangedHandler> dispatcher; public Model() { dispatcher = new EventDispatcher<ModelChangedHandler>("modelChanged"); } public void whenModelChange(ModelChangedHandler handler) { dispatcher.add(handler); } public void change() { dispatcher.dispatch(); } } ModelChangedHandler: package model; public interface ModelChangedHandler { void modelChanged(); } Presenter: package presenter; public class Presenter { private final Model model; public Presenter(Model model) { this.model = model; this.model.whenModelChange(new ModelChangedHandler() { @Override public void modelChanged() { System.out.println("model changed"); } }); } } Main: package main; public class Main { public static void main(String[] args) { Model model = new Model(); Presenter presenter = new Presenter(model); model.change(); } } Now, I except to get the "model changed" message. However, I'm getting an java.lang.IllegalAccessException: Class utils.EventDispatcher can not access a member of class presenter.Presenter$1 with modifiers "public". I understand that the class to blame is the anonymous class i created inside the presenter, however I don't know how to make it any more 'public' than it currently is. If i replace it with a named nested class it seem to work. It also works if the Presenter and the EventDispatcher are in the same package, but I can't allow that (several presenters in different packages should use the EventDispatcher) any ideas?

    Read the article

  • SQL SERVER – Configuring Interactive Cleansing Suggestion Min Score for Suggestions in Data Quality Services (DQS) – Sensitivity of Suggestion

    - by pinaldave
    Earlier I talked about what kind of questions, I do not like when I get asked. Today we will go over the question which I like when I get asked the same. One of the reader practices various steps in my earlier blog post Step by Step Guide to Beginning Data Quality Services in SQL Server 2012 – Introduction to DQS. While reading the blog post he noticed that Data Quality Services is not providing very helpful suggestions. He wrote an email to me about it. Let us go over his email. “Pinal, I noticed in one of your images that DQS is not providing very helpful suggestions. First of all DQS should be able to make intelligent guesses and make the necessary correction by itself. If it cannot do the same, in that case, it should give us intelligent suggestions but in the image included here, I see the suggestions are not there as well. Why is it so? Would you please tell me how to increase the numbers of suggestion? I do understand this may not be preferable solution in many case but all the business cases go on it depends. There are cases when the high sensitivity required and there are cases when higher sensitivities are not required. I would like to seek your help here. –Sriram MD” This is indeed a great question. I see that Sriram understands that every system is different and every application has a different need. I will not have to tell him this most important concept. The question is about how to change the sensitivity of suggestions for correction in DQS. Well, this option is available under the configuration tab in the DQS client. Once you click on Configuration you will see the following screen. Click the Tab of General Settings. You will see the section of Interactive Cleansing. Under this second there is the first option of “Min score for suggestions”. As this is set to 0.7 every suggestion which matches 0.7 probabilities or higher probability are displayed under the suggestion tab. You can see in the following image that there is no suggestion as the min score for suggestions is set to 0.7 and there is no record which qualifies to that much confidence. Now let us change the value of Min Score for suggestion to 0.5. The lower value increased the confidence of DQS to give further suggestion to values which are over 0.5. However, in our case the suggestions which it provides are also accurate. This may not be true for your sample. Every sample is different so you should manually review it before approving them. I guess, this is a simple blog post to demonstrate how to change the confidence value for the suggestions which Data Quality Services provides. Use this feature with care and always tune it according to your datasets and record diversity. Reference: Pinal Dave (http://blog.SQLAuthority.com)       Filed under: PostADay, SQL, SQL Authority, SQL Query, SQL Server, SQL Tips and Tricks, T SQL, Technology Tagged: Data Quality Services, DQS

    Read the article

  • Essbase BSO Data Fragmentation

    - by Ann Donahue
    Essbase BSO Data Fragmentation Data fragmentation naturally occurs in Essbase Block Storage (BSO) databases where there are a lot of end user data updates, incremental data loads, many lock and send, and/or many calculations executed.  If an Essbase database starts to experience performance slow-downs, this is an indication that there may be too much fragmentation.  See Chapter 54 Improving Essbase Performance in the Essbase DBA Guide for more details on measuring and eliminating fragmentation: http://docs.oracle.com/cd/E17236_01/epm.1112/esb_dbag/daprcset.html Fragmentation is likely to occur in the following situations: Read/write databases that users are constantly updating data Databases that execute calculations around the clock Databases that frequently update and recalculate dense members Data loads that are poorly designed Databases that contain a significant number of Dynamic Calc and Store members Databases that use an isolation level of uncommitted access with commit block set to zero There are two types of data block fragmentation Free space tracking, which is measured using the Average Fragmentation Quotient statistic. Block order on disk, which is measured using the Average Cluster Ratio statistic. Average Fragmentation Quotient The Average Fragmentation Quotient ratio measures free space in a given database.  As you update and calculate data, empty spaces occur when a block can no longer fit in its original space and will either append at the end of the file or fit in another empty space that is large enough.  These empty spaces take up space in the .PAG files.  The higher the number the more empty spaces you have, therefore, the bigger the .PAG file and the longer it takes to traverse through the .PAG file to get to a particular record.  An Average Fragmentation Quotient value of 3.174765 means the database is 3% fragmented with free space. Average Cluster Ratio Average Cluster Ratio describes the order the blocks actually exist in the database. An Average Cluster Ratio number of 1 means all the blocks are ordered in the correct sequence in the order of the Outline.  As you load data and calculate data blocks, the sequence can start to be out of order.  This is because when you write to a block it may not be able to place back in the exact same spot in the database that it existed before.  The lower this number the more out of order it becomes and the more it affects performance.  An Average Cluster Ratio value of 1 means no fragmentation.  Any value lower than 1 i.e. 0.01032828 means the data blocks are getting further out of order from the outline order. Eliminating Data Block Fragmentation Both types of data block fragmentation can be removed by doing a dense restructure or export/clear/import of the data.  There are two types of dense restructure: 1. Implicit Restructures Implicit dense restructure happens when outline changes are done using EAS Outline Editor or Dimension Build. Essbase restructures create new .PAG files restructuring the data blocks in the .PAG files. When Essbase restructures the data blocks, it regenerates the index automatically so that index entries point to the new data blocks. Empty blocks are NOT removed with implicit restructures. 2. Explicit Restructures Explicit dense restructure happens when a manual initiation of the database restructure is executed. An explicit dense restructure is a full restructure which comprises of a dense restructure as outlined above plus the removal of empty blocks Empty Blocks vs. Fragmentation The existence of empty blocks is not considered fragmentation.  Empty blocks can be created through calc scripts or formulas.  An empty block will add to an existing database block count and will be included in the block counts of the database properties.  There are no statistics for empty blocks.  The only way to determine if empty blocks exist in an Essbase database is to record your current block count, export the entire database, clear the database then import the exported data.  If the block count decreased, the difference is the number of empty blocks that had existed in the database.

    Read the article

  • unable to recover data from failed hdd

    - by Eslam Elyamany
    my hdd failing (or maybe totally dead) i've connected the hdd via USB but it doesn't appear in fdisk Disk /dev/sda: 500.1 GB, 500107862016 bytes 255 heads, 63 sectors/track, 60801 cylinders, total 976773168 sectors Units = sectors of 1 * 512 = 512 bytes Sector size (logical/physical): 512 bytes / 4096 bytes I/O size (minimum/optimal): 4096 bytes / 4096 bytes Disk identifier: 0xe9fb38fb Device Boot Start End Blocks Id System /dev/sda1 * 2048 206847 102400 7 HPFS/NTFS/exFAT /dev/sda2 206848 40959999 20376576 7 HPFS/NTFS/exFAT /dev/sda4 40962046 976771071 467904513 5 Extended Partition 4 does not start on physical sector boundary. /dev/sda5 82913280 86910975 1998848 82 Linux swap / Solaris /dev/sda6 86913024 394113023 153600000 7 HPFS/NTFS/exFAT /dev/sda7 40962048 82913279 20975616 83 Linux /dev/sda8 394122708 976768064 291322678+ 7 HPFS/NTFS/exFAT Partition 8 does not start on physical sector boundary. no sdc appears here , BUT it's appears on /dev/ rootghost-lap:/home/ghost# ls /dev/sd* /dev/sda /dev/sda2 /dev/sda5 /dev/sda8 /dev/sdb /dev/sdc1 /dev/sdc2 /dev/sdc6 /dev/sdc8 /dev/sda1 /dev/sda4 /dev/sda6 /dev/sda9 /dev/sdc /dev/sdc10 /dev/sdc5 /dev/sdc7 /dev/sdc9 also it appears in proc Code: rootghost-lap:/home/ghost# cat /proc/partitions major minor #blocks name 8 0 488386584 sda 8 1 102400 sda1 8 2 20376576 sda2 8 4 1 sda4 8 5 1998848 sda5 8 6 153600000 sda6 8 8 291322678 sda8 8 9 20975616 sda9 11 0 1048575 sr0 11 1 99136 sr1 8 32 244198583 sdc 8 33 14651248 sdc1 8 34 1 sdc2 8 37 15380480 sdc5 8 38 4153344 sdc6 8 39 48829536 sdc7 8 40 48829536 sdc8 8 41 110374551 sdc9 8 42 1975963 sdc10 and dmesg : [10604.777168] end_request: I/O error, dev sdc, sector 1 [10604.817238] sd 26:0:0:0: [sdc] Result: hostbyte=DID_OK driverbyte=DRIVER_SENSE [10604.817243] sd 26:0:0:0: [sdc] Sense Key : Aborted Command [current] [10604.817248] sd 26:0:0:0: [sdc] Add. Sense: No additional sense information [10604.817253] sd 26:0:0:0: [sdc] CDB: Read(10): 28 00 00 00 00 02 00 00 06 00 ok now , let's see what i've tried testdisk to check for partitions -- failed dd to copy data from /dev/sdcX -- provide strange output size for example /dev/sdc1 is about 15G , the output for dd is 62G+ so i had to cancle it safecopy successfully made an image for partitons , but can't fix images, can't mount it, can't do any thing with it and some other tools i've tried and all failed , so any idea ?

    Read the article

  • Restoring MBR, partition table, and boot sector of memory card without data loss ("USBC")

    - by Synetech
    Abstract I have a FAT32 memory card that when inserted into a computer causes Windows to prompt to format it. The card is definitely not supposed to be blank and has a bunch of files on it. Symptoms Using a hex-editor/disk-viewer, I examined the card and found that several sectors/clusters have been overwritten with something that has a signature of USBC at the start of the sector. Specifically, the master boot record (and partition table) is gone (hence Windows thinking the card is blank and needing to be formatted), as are the boot sectors (they have the USBC signature and a volume label of NO NAME and partition type of FAT32). Fortunately, it looks like both copies of the FAT are almost entirely intact (a few FAT entries at the start of a cluster here and there seem to be overwritten by USBC). The root directory is also nearly intact—I can see the volume label entry and subdirectory listings, but one sector is overwritten. (There are no more instances of USBC after the last one in the FAT2.) Hypothesis These observations seem to indicate some sort of virus that erases a few key filesystem structures, and then overwrites a few extra sectors here and there. Googling it seems to corroborate the idea of a virus, except that others report a file called USBC which does not apply here, and in fact, could not be possible since there is no filesystem to even see files. I cannot find any information about a virus with these symptoms, nor a removal tool. (I can't help but wonder if it is actually due to an autorun virus prevention tool.) Question I can likely fix the FAT corruption since they are mostly contiguous chains and maybe even the lost sector of the root directory, but does anyone know of a convenient way to restore or (re)create the MBR/partition table and boot sectors (without formatting or overwriting the data)?

    Read the article

  • Struggling to create correct relationships in MS Access

    - by Yandawl
    http://img714.imageshack.us/img714/7820/croppercapture1.png Basically: an award(course) has many units, which can be either optional or core(mandatory), depending on the award. So for example: the unit 'Advanced Software Engineering' maybe a core unit for the award 'Software Engineering BSc' but only an optional unit for the course 'Web Technology BSc'. I've used flags for that purpose. A student is enrolled on an award so I need to get a complete list of core and optional units (bearing in mind that a student chooses 1 out of many possible optional units). Also, these units have events, e.g, a lecture, workshop or seminar, etc. and those events have sessions or instances of events where students enrolled on that particular unit are required to attend, and those attendances are stored in a separate table to form a register. So I need a hierarchy of expanding the tables something like this I guess: Awards - Students - Units - Sessions - Attendances Any help with this would be appreciated... It's blowing my mind and I'm really close to going insane! My tutor didn't spot I'd got it wrong when I showed my original data model to him and it's due in next week! Thank you :D

    Read the article

  • INSERT INTO in MS Access 2010 SOMETIMES GETS ERROR: 3073 Operation must use an updateable query

    - by Gary
    I get the ERROR: 3073 Operation must use an updateable query SOMETIMES, while performing an INSERT statment. I have no problem on my windows 7 PC, but the person I am writing this for sometimes gets the error. She also has MS Access 2010 on Windows 7. As I said I have never got it on my PC, and she only gets it sometimes. The code will insert a number of rows and then through the error, and other times not through the erro at all. The error occurs if I have the code and data in one .mdb file or seperate files. Here a snippet of code: OrderHdrInsertStmnt = " INSERT INTO ORDER_HDR " _ & "(ORDER_ID, SOURCE_CODE, ORDER_DATE, SHIP_FNAME, SHIP_LNAME, SHIP_EMAIL, SHIP_COMP, SHIP_PHONE, SHIP_ADDR, SHIP_CITY, SHIP_STATE, SHIP_ZIP, SHIP_CNTRY, " _ & " BILL_FNAME, BILL_LNAME, BILL_EMAIL, BILL_COMP, BILL_PHONE, BILL_ADDR, BILL_CITY, BILL_STATE, BILL_ZIP, BILL_CNTRY, " _ & " TAX, SHIPPING, TOTAL, MOD_DATE, INSERT_DATE) " _ & " VALUES (" _ & "'" & OrderId & "','" & SourceCode & "','" & Orderdate & "','" & ShipFName & "','" & ShipLName & "','" & ShipEmail & "','" & ShipComp & "','" & ShipPhone & "','" & ShipAddr & "','" & ShipCity & "','" & ShipState & "','" & ShipZip & "','" & ShipCntry _ & "','" & BillFName & "','" & BillLName & "','" & BillEmail & "','" & BillComp & "','" & BillPhone & "','" & BillAddr & "','" & BillCity & "','" & BillState & "','" & BillZip & "','" & BillCntry _ & "','" & OrderTax & "','" & OrderShipping & "','" & OrderTotal & "','" & ImportDate & "','" & ImportDate & "');" then I use dbsCurrent.Execute OrderHdrInsertStmnt, dbFailOnError Any assistance would be great!

    Read the article

  • MS Access PIVOT with User Defined Field

    - by user2535359
    Any of you good souls please help!! I need to query the source table shown in the below. (NULL are blank fields) UNUM, Ticket, Overflow 1 , 135 , NULL 1 , 136 ,NULL 1, 137, NULL 1, 138, NULL 1, NULL, 2b 2, 135, NULL 2, 136, NULL 2, 137, NULL 3, 135, NULL 3, 136, NULL 3, 137,NULL 3, 138, NULL 3, 139, NULL 3, 140, NULL 3, NULL, 66a 4, NULL, 12a 5, NULL, 14a I need to generate the output as shown below. UserNum, Ticket1, Ticket2, Ticket3, Ticket4, Ticket5, Ticket6, Ticket7, Ticket8, Ticket9, Overflow 1, 135, 136, 137, 138, Null, Null, Null, Null, Null, 2b 2, 135, 136, 137, Null, Null, Null, Null, Null, Null, Null 3, 135, 136, 137, 138, 139, 140, Null, Null, Null, 66a 4, Null, Null, Null, Null, Null, Null, Null, Null, Null, 12a 5, Null, Null, Null, Null, Null, Null, Null, Null, Null, 14a The source table has multiple tickets assigned to user. There are always maximum of 9 tickets. The user either has a ticket or an overflow but here can be only overflow per user. I am having issue pivoting the data in Ticket column to pre-defined field names like Ticket1, Ticket2...

    Read the article

  • OData to the rescue. Exposing the eventlog as a data feed

    - by cibrax
    In one of the project where I was working one, we used the Microsoft Enterprise Library Exception Application Block integration with WCF for logging all the technical issues on the services/backend in Windows Event Log. This application block worked like a charm, all the errors were correctly logged on the Event Log without even needing to modify the service code. However, we also needed to provide a quick way to expose all those events to the different system users so they could get access to all the them remotely. In just a couple of minutes I came up with a simple solution based on ADO.NET Data Services. ADO.NET data services is very powerful in this sense, you only need to provide a IQueryable implementation, and that’s all. You get a RESTful service with rich query support for free. In this sample, I used Linq to Objects to get the latest entries from the Event Log, and I also filter the entries by the category used by the Application Block to avoid loading unnecessary entries in memory. public class LogDataSource     {         string source;         public LogDataSource(string source)         {             this.source = source;         }         public LogDataSource()         {         }         public IQueryable<LogEntry> LogEntries         {             get { return GetEntries().AsQueryable().OrderBy(e => e.TimeGenerated); }         }         private IEnumerable<LogEntry> GetEntries()         {             var applicationLog = System.Diagnostics.EventLog.GetEventLogs().Where(e => e.Log == "Application")                 .FirstOrDefault();             var entries = new List<LogEntry>();             if (applicationLog != null)             {                 foreach (EventLogEntry entry in applicationLog.Entries)                 {                     if (source == null || entry.Source.Equals(source, StringComparison.InvariantCultureIgnoreCase))                     {                         entries.Add(new LogEntry                         {                             Category = entry.Category,                             EventID = entry.InstanceId,                             Message = entry.Message,                             TimeGenerated = entry.TimeGenerated,                             Source = entry.Source,                         });                     }                 }             }             return entries.OrderByDescending(e => e.TimeGenerated)                         .Take(200);         }     } LogEntry is class I created for this service to expose an Event Log Entry.     [EntityPropertyMappingAttribute("Source",         SyndicationItemProperty.Title,         SyndicationTextContentKind.Plaintext, true)]     [EntityPropertyMapping("Message",         SyndicationItemProperty.Summary,         SyndicationTextContentKind.Plaintext, true)]     [EntityPropertyMapping("TimeGenerated",         SyndicationItemProperty.Updated,         SyndicationTextContentKind.Plaintext, true)]     [DataServiceKey("EventID")]     public class LogEntry     {         public long EventID         {             get;             set;         }         public string Category         {             get;             set;         }         public string Message         {             get;             set;         }         public DateTime TimeGenerated         {             get;             set;         }         public string Source         {             get;             set;         }     } As you can see, I used the new feature “Friendly feeds” to map several properties in the entries with standard ATOM elements. The “DataServiceKey” is only necessary because I am using the Reflection Provider (the exposed IQueryable implementation is just Linq to Objects) rather than the default Entity Framework Provider. The data service implementation is also quite simple, just a couple of lines were needed to expose the data source created previously. public class LogDataService : DataService<LogDataSource>     {         public static void InitializeService(IDataServiceConfiguration config)         {             config.SetEntitySetAccessRule("*", EntitySetRights.AllRead);         }         protected override LogDataSource CreateDataSource()         {             string source = ConfigurationManager.AppSettings["EventLogSource"];             if (source == null)             {                 throw new ApplicationException("The EventLogSource appsetting is missing in the configuration file");             }             return new LogDataSource(source);         }     } With this implementation in place, the final users not only get a feed with all the latest errors in the event log, but also support for performing queries against that data. This is one of the great things about ADO.NET Data services.

    Read the article

  • Visiting the Emtel Data Centre

    Back in February at the first event of the Emtel Knowledge Series (EKS) I spoke to various people at Emtel about their data centre here on the island. I was trying to see whether it would be possible to arrange a meeting over there for a selected group of our community members. Well, let's say it like this... My first approach wasn't that promising and far from successful but during the following months there were more and more occasions to get in touch with the "right" contact persons at Emtel to make it happen... Setting up an appointment and pre-requisites The major improvement came during a Boot Camp for Windows Phone 8.1 App development organised by Microsoft Indian Ocean Islands in cooperation with Emtel at the Emtel World, Ebene. Apart from learning bits and pieces regarding Universal Apps I took the opportunity to get in touch with Arvin Lockee, Sales Executive - Data, during our lunch break. And this really kicked off the whole procedure. Prior to get access to the Emtel data centre it is requested that you provide full name and National ID of anyone going to visit. Also, it should be noted that there was only a limited amount of seats available. Anyways, packed with this information I posted through the usual social media channels. Responses came in very quickly and based on First-come, first-serve (FCFS) principle I noted down the details and forwarded them to Emtel in order to fix a date and time for the visit. In preparation on our side, all attendees exchanged contact details and we organised transport options to go to the data centre in Arsenal. The day before and on the day of our meeting, Arvin send me a reminder to check whether everything is still confirmed and ready to go... Of course, it was! Arriving at the Emtel Data Centre As I'm coming from Flic En Flac towards the North, we agreed that I'm going to pick up a couple of young fellows near the old post office in Port Louis. All went well, except that Sean eventually might be living in another time zone compared to the rest of us. Anyway, after some extended stop we were complete and arrived just in time in Arsenal to meet and greet with Ish and Veer. Again, Emtel is taking access procedures to their data centre very serious and the gate stayed close until all our IDs had been noted and compared to the list of registered attendees. Despite having a good laugh at the mixture of old and new ID cards it was a straight-forward processing. The ward was very helpful and guided us to the waiting area at the entrance section of the building. Shortly after we were welcomed by Kamlesh Bokhoree, the Data Centre Officer. He gave us brief introduction into the rules and regulations during our visit, like no photography allowed, not touching the buttons, and following his instructions through the whole visit. Of course! Inside the data centre Next, he explained us the multi-factor authentication system using a combination of bio-metric data, like finger print reader, and "classic" pin panel. The Emtel data centre provides multiple services and next to co-location for your own hardware they also offer storage options for your backup and archive data in their massive, fire-resistant vault. Very impressive to get to know about the considerations that have been done in choosing the right location and how to set up the whole premises. It should also be noted that there is 24/7 CCTV surveillance inside and outside the buildings. Strengths of the Emtel TIER 3 Data Centre, Mauritius Finally, we were guided into the first server room. And wow, the whole setup is cleverly planned and outlined in the architecture. From the false floor and ceilings in order to provide optimum air flow, over to the separation of cold and hot aisles between the full-size server racks, and of course the monitored air conditions in order to analyse and watch changes in temperature, smoke detection and other parameters. And not surprisingly everything has been implemented in two independent circuits. There is a standardised classification for the construction and operation of data centres world-wide, and the Emtel's one has been designed to be a TIER 4 building but due to the lack of an alternative power supplier on the island it is officially registered as a TIER 3 compliant data centre. Maybe in the long run there might be a second supplier of energy next to CEB... time will tell. Luckily, the data centre is integrated into the National Fibre Optic Gigabit Ring and Emtel already connects internationally through diverse undersea cable routes like SAFE & LION/LION2 out of Mauritius and through several other providers for onwards connectivity. The data centre is part of the National Fibre Optic Gigabit Ring and has redundant internet connectivity onwards. Meanwhile, Arvin managed to join our little group of geeks and he supported Kamlesh in answering our technical questions regarding the capacities and general operation of the data centre. Visiting the NOC and its dedicated team of IT professionals was surely one of the visual highlights. Seeing their wall of screens to monitor any kind of activities on the data lines, the managed servers and the activity in and around the building was great. Even though I'm using a multi-head setup since years I cannot keep it up with that setup... ;-) But I got a couple of ideas on how to improve my work spaces here at the office. Clear advantages of hosting your e-commerce and mobile backends locally After the completely isolated NOC area we continued our Q&A session with Kamlesh and Arvin in the second server room which is dedictated to shared environments. On first thought it should be well-noted that there is lots of space for full-sized racks and therefore co-location of your own hardware. Actually, given the feedback that there will be upcoming changes in prices the facilities at the Emtel data centre are getting more and more competitive and interesting for local companies, especially small and medium enterprises. After seeing this world-class infrastructure available on the island, I'm already considering of moving one of my root servers abroad to be co-located here on the island. This would provide an improved user experience in terms of site performance and latency. This would be a good improvement, especially for upcoming e-commerce solutions for two of my local clients. Later on, we actually started the conversation of additional services that could be a catalyst for the local market in order to attract more small and medium companies to take the data centre into their evaluations regarding online activities. Until today Emtel does not provide virtualised server environments but there might be ongoing plans in the future to cover this field as well. Emtel is a mobile operator and internet connectivity provider in the first place, entering a market of managed and virtualised server infrastructures including capacities in terms of cloud storage and computing are rather new and there is a continuous learning curve at Emtel, too. You cannot just jump into a new market and see how it works out... And I appreciate Emtel's approach towards a solid fundament and then building new services on top of that. Emtel as a future one-stop-shop service provider for all your internet and telecommunications needs. Emtel's promotional video about their TIER 3 data centre in Arsenal, Mauritius More details are thoroughly described in Emtel's brochure of their data centre. Check out their PDF document here. Thanks for this opportunity Visiting and walking through the Emtel data centre for more than 2 hours was a great experience. As representative of the Mauritius Software Craftsmanship Community (MSCC) I would like to thank anyone at Emtel involved in the process of making it happen, and especially to Arvin Lockee and Kamlesh Bokhoree for their time and patience in explaining the infrastructure and answering all the endless questions from our members. Thank You!

    Read the article

  • Jquery data retrival returns null with json data

    - by user545520
    Hello Everyone, I have below sample json file: {"jsonData":{"REC":[{"TEST":"T","TEST1":"T1","TEST2":"T2"},{"R":"R","R1":"R1","R3":"R3"}], "DATA":{"FIRST":0,"SEC":1}}}. I want to retrieve data from json file,i am try like below,but it is giving null. from result object:i am retrieving data like below: to retrive the value T: this.jsonData.REC.TEST To retrieve the value R1: this.jsonData.DATA.FIRST Please correct me if i am doing any wrong. Thanks in Advance.

    Read the article

  • Wireless access point -> Powerline -> Router -> Internet, should this work?

    - by Anthony
    My network at home used to be a laptop and desktop connected wirelessly to a single Wireless ADSL router, a Cisco 877W. Wireless reception around the house with this setup was quite unreliable, so I've gone about looking to improve it. I purchased some Belkin Gigabit powerline adapters and I've got these working fine. I can hook a computer up to one of the powerline adapters, and with the other one plugged into the ADSL router the computer has internet access. Additionally I can hook a Netgear DG834G Wireless ADSL router into it with the adsl not plugged in, and after turning off DHCP can RJ45 a computer up to the network. Everything works fine. However, if I setup a wireless network on the Netgear then any computer that connects wirelessly to it cannot access the internet. It gets an IP address very slowly via DHCP which is a good one, but it cannot access the internet. It can however communicate with the RJ45'd computer also connected to the Netgear. I wondered whether this could be a problem with the Netgear so I've borrowed a Cisco Aironet 1200 and got this working fine when it's attached directly to the primary ADSL router. I can connect to it wireless and get onto the internet. However, if I then plug it into the Netgear I can communicate with other devices attached to the Netgear, but can't get any further than the Netgear. All the while though the other devices RJ45'd to the Netgear are communicating with the internet just fine. I'm starting to suspect it's one of two things causing the problem: 1) For some reason the belkin powerline adapters don't like carrying wireless-originating signals. Could this be possible? 2) The primary Cisco ADSL router doesn't want to communicate with other devices on my network more than one hop away from it. I'm making an assumption here that within the Netgear box the wireless and wired sides are handled differently. Could this be true? Has anyone successfully setup something similar to what I'm trying, with a wireless device on the otherside of a pair of powerline connectors? Update 06/07/2010 - Response to irrational John 28 June Thanks for the answer John - and for clearing up some of my questions. The model number of the belkin powerline adapters are F5D4076. Security was apparently enabled by default on them, and I didn't change them from their default setting. The network diagram in your answer shows exactly what I'm trying to setup: I've followed that guide and I'm still not able to get things working properly. The thing that perplexes me is that wired network traffic works just fine - it's only the wireless traffic that doesn't. This is with the same laptop, and the same DHCP or static IPs. "1. What IP addresses did you assign to each router? What subnet masks are you using?" - subnet is 255.255.255.0, the router connected to the adsl is 192.168.153.1 and that has the DHCP server. The access point on the other side of the powerline adapters I've tried both a static IP of 192.168.153.110, same subnet, and a DHCP-assigned IP. The other devices are DHCP, although I also tried manually entering IP settings. "2. Have you correctly enabled DHCP on only one of the routers and disabled it on all the others?" Yes I have - only the internet-connected router has DHCP enabled. The IP range for the DHCP is from 192.168.153.11 - 192.168.153.200. The strange thing is that wired connections work fine on the LAN, plugged into any router, work fine - it's only the wireless connections that aren't working when they're plugged into the non-primary AP. "Since the routers you are using appear to integrate an ADSL modem I'm assuming there is no WAN port on them." There's no NAT within the LAN, and all wired connections are connected to LAN ports. It's something wrong with the wireless - wired works fine throughout the whole LAN. Update 06/07/2010 - Response to irrational John 29 June The diagram you've drawn in your answer shows pretty much exactly what I'm trying to do. I've spent another evening trying different things and made some progress but I'm still scratching my head. I've borrowed a Netgear access point and been trying with this, and the strange thing is that my PC is working now - this is a Windows 7 PC connected to the access point in the position of where the DG834G is in the diagram. Meanwhile, however, I have an old Powerbook G4 12" I use for music, and while that has a DHCP-assigned IP address, it's not getting any network throughput to either LAN or internet addresses. To make matters more strange, my phone appears to be intermittently working when it's on the wifi. The access point is a Netgear WPN802v1, DHCP, NAT both switched off, running firmware 2.0.9.0. Last night I set it up with exactly the same settings, and similar to tonight I could get a couple of devices to work, and a couple not to. By the morning, however, everything had stopped working - nothing could get a DHCP IP address. I rebooted the 877W earlier this evening and I'm wondering whether this is why a few things are working now. "Could it be possible that the issue could be with the 877W?" I didn't configure this - is it possible that the DHCP server only likes assigning devices that are immediately attached to it? Or similar, could a firewall be stopping too many addresses that are coming through one device? (ie. the Access Point) This could explain why devices are working at the start but then not by the end. In reply to your questions, "1. I looked at the Netgear DG834G support page. There are five versions of this router. Which version do you have? Netgear usually lists this on the label on the bottom of the router. What version of the firmware does it have?" It's a DG834Gv3, and the firmware is the last on the netgear site version 4.01.40. "3. Not knowing which version you have, I glanced at the reference manual for the DG834G v3. In the section for Wireless Settings under the subsection Wireless Access Point there is a check box for a Wireless Isolation setting. If you have this setting it should be off/unchecked. If it is checked then any device connected via wireless would not be able to talk to any other device on the LAN. This sounds like your problem so maybe this is the cause?" I've checked this and it's switched off. I've made a change to the IP of the access point to something outside the DHCP range - it's now 192.158.153.5, with DHCP starting at 11 and going up to 254. Thanks for the tip about this - I only have a few devices so wouldn't anticipate the DHCP server assigning up to 110, but better safe than sorry. Finally one more thing I thought I should add, is with the Powerbook G4 that's not working - it's getting a DHCP IP address and it can communicate with the WPN802 as I can visit the administration page. Anything further than this, however, it can't reach; I can't administrate the 192.168.153.1 (877W router). Strangely, however, when I open Finder on the same powerbook it's detecting my NAS which is attached directly via wire to the 877W. If I try to browse it, it says connection failed. RE: "Perhaps the problem with your Powerbook is with DNS?.." The IP settings on the powerbook are identical to that of the PC with the exception of the IP address; the PC is 192.168.153.17 and the powerbook is 192.168.153.12. Subnets are the same, 255.255.255.0 and default gateway is the same, .1, and the DNS servers are the same. I administrate the 877W by going to 192.168.153.1 in the browser. This is what isn't working from the Powerbook, despite the PC working fine when I do the same. Meanwhile, however, I can administrate the AP on 192.168.153.5 from both PC and Powerbook Update 06/07/2010 - FINAL RESOLUTION of sorts: First off, sorry for the length of this question. I need start to practice a more concise writing style, so I'm going to try to keep this bit brief. After much fiddling, and with the hugely-appreciated help of irrational John, I have come to the conclusion that it's something wrong with the powerbook. I believe that this was perhaps the reason I doubted things worked at the very beginning. I now have the original DG834Gv3 running both wirelessly and wired, and both wired devices and wireless devices get internet connectivity. The only anomaly is the powerbook which I've had to keep wired, as no matter what I do it refuses to work wirelessly. I still have suspicions that the 877W isn't quite right; I'm fairly sure that if I RJ45 the powerline adapter into a different LAN port on it then everything will break. I've just about run out of patience to test this further, and I think I need to go into the 877W's config to match the 877w's lan port's settings. I'm accepting irrational John's answer as he's been enormously helpful, way above the call of duty, and for this line he wrote: Beats the heck out of me. which in the midst of great frustration made me chuckle, and for a sentence in one of his comments to the same answer: If it is specific to the Powerbook I would put that issue aside until after you feel you have the rest of your LAN and the additional WAP all working together correctlyt It was this second sentence that made me put the powerbook aside and concentrate on the other devices that ultimately led me to getting things working.

    Read the article

  • MessageBox if Recordset Update is Successful

    - by Paolo Bernasconi
    In Access 2007, I have a form to add a new contact to a table: RecSet.AddNew RecSet![Code_Personal] = Me.txtCodePersonal.Value RecSet![FName] = Me.TxtFName.Value RecSet![LName] = Me.txtLName.Value RecSet![Tel Natel] = Me.txtNatTel.Value RecSet![Tel Home] = Me.txtHomeTel.Value RecSet![Email] = Me.txtEmail.Value RecSet.Update This has worked so far, and the contact has successfully been aded. But I'm having two problems: I want to display a messagebox to tell the user the contact was successfully added If the contact was not successfully added because A contact with this name already exists A different issue Then display a message box "Contact already exists" or "error occured" respectively. My idea of doing this is: If recSet.Update = true Then MsgBox "Paolo Bernasconi was successfully added" Else if RecSet![FName] & RecSet![LName] 'already exist in table MsgBox "Contact already exists" Else MsgBox "An unknown error occured" I know this code is wrong, and obviously doesn't work, but it's just to give you an idea of what I'm trying to achieve. Thanks for all your help in advance.

    Read the article

  • Is information a subset of data?

    - by Jason Baker
    I apologize as I don't know whether this is more of a math question that belongs on mathoverflow or if it's a computer science question that belongs here. That said, I believe I understand the fundamental difference between data, information, and knowledge. My understanding is that information carries both data and meaning. One thing that I'm not clear on is whether information is data. Is information considered a special kind of data, or is it something completely different?

    Read the article

  • isPostBack as Query Parameter

    - by Steven
    I created an ASPX page with search controls to the left bound as controls for an AccessDataSource. I want the data grid to be blank on the first calling of the page, but show the results for subsequent page loads. I plan to achieve this by putting [pFirstRun] = False as my first WHERE condition with the parameter pFirstRun tied to the value isPostBack. How do I achieve this? Alternatively, is there a better way to achieve this goal?

    Read the article

  • MySQL data type: Text,,, Erroring: Data Too Long

    - by nobosh
    I have a field as follows in MySQL: Type: Text Length: 0 Decimals: 0 And when I try to insert data around the size of 4 pages of MS Word, Coldfusion errors with: Data Too Long from the DB. I thought TEXT data type was able to expand and handle this size of data? What am I missing and what can I do?

    Read the article

  • Converting DAO to ADO

    - by webworm
    I am working with an Access 2003 database that has a subroutine using DAO code. This code loops through the table definitions and refreshes the ODBC connection string. I would like to convert this to ADO so I do not have to reference the DAO object library. Here is the code ... Public Sub RefreshODBCLinks(newConnectionString As String) Dim db As DAO.Database Dim tb As DAO.TableDef Set db = CurrentDb For Each tb In db.TableDefs If Left(tb.Connect, 4) = "ODBC" Then tb.Connect = newConnectionString tb.RefreshLink Debug.Print "Refreshed ODBC table " & tb.Name End If Next tb Set db = Nothing MsgBox "New connection string is " & newConnectionString, vbOKOnly, "ODBC Links refreshed" End Sub The part I am unsure of is how to loop through the tables and get/set their connection strings.

    Read the article

  • Access Violation

    - by Justin
    I've been learning how to NOP functions in C++ or even C but there are very few tutorials online about it. I've been googling for the past few hours now and I'm just stuck. Here is my code. #include <iostream> #include <windows.h> #include <tlhelp32.h> using namespace std; //#define NOP 0x90 byte NOP[] = {0x90}; void enableDebugPrivileges() { HANDLE hcurrent=GetCurrentProcess(); HANDLE hToken; BOOL bret=OpenProcessToken(hcurrent,40,&hToken); LUID luid; bret=LookupPrivilegeValue(NULL,"SeDebugPrivilege",&luid); TOKEN_PRIVILEGES NewState,PreviousState; DWORD ReturnLength; NewState.PrivilegeCount =1; NewState.Privileges[0].Luid =luid; NewState.Privileges[0].Attributes=2; AdjustTokenPrivileges(hToken,FALSE,&NewState,28,&PreviousState,&ReturnLength); } DWORD GetProcId(char* ProcName) { PROCESSENTRY32 pe32; HANDLE hSnapshot = NULL; pe32.dwSize = sizeof( PROCESSENTRY32 ); hSnapshot = CreateToolhelp32Snapshot( TH32CS_SNAPPROCESS, 0 ); if( Process32First( hSnapshot, &pe32 ) ) { do{ if( strcmp( pe32.szExeFile, ProcName ) == 0 ) break; }while( Process32Next( hSnapshot, &pe32 ) ); } if( hSnapshot != INVALID_HANDLE_VALUE ) CloseHandle( hSnapshot ); return pe32.th32ProcessID; } void WriteMem(DWORD Address, void* Value, size_t Size) { DWORD Protect = NULL; VirtualProtect((LPVOID)Address, 3, PAGE_READWRITE, &Protect); memcpy((void*)Address, Value, 3); VirtualProtect((LPVOID)Address, 3, Protect, &Protect); } void nop_(PVOID address, int bytes){ DWORD d, ds; VirtualProtect(address, bytes, PAGE_EXECUTE_READWRITE, &d); memset(address, 144, bytes); VirtualProtect(address,bytes,d,&ds); } void MemCopy(HANDLE pHandle, void* Dest, const void* Src, int Len) { DWORD OldProtect; DWORD OldProtect2; VirtualProtect(Dest, Len, PAGE_EXECUTE_READWRITE, &OldProtect); memcpy(Dest, Src, Len); VirtualProtect(Dest, Len, OldProtect, &OldProtect2); FlushInstructionCache(pHandle, Dest, Len); } int main() { enableDebugPrivileges(); DWORD pid; HANDLE phandle; // Obtain the process ID pid = GetProcId("gr.exe"); if(GetLastError()) { cout << "Error_PID_: " << GetLastError() << endl; system("pause"); return -1; } // Obtain the process handle phandle = OpenProcess(PROCESS_ALL_ACCESS,0,pid); if(GetLastError()) { cout << "Error_HANDLE_: " << GetLastError() << endl; system("pause"); return -1; } // Debug info, 0 = bad cout <<"pid : " << pid << endl; cout <<"HANDLE: " << phandle << endl << endl; system("pause"); // Change value to short iValue = -1; int choice = 0; BYTE * bGodMode = (BYTE *) (0x409A7E); // Lives Address bool hack = true; while(hack) { system("cls"); cout << "What hack?\n0. Exit\n1. Lives\n\n!> "; cin >> choice; switch(choice) { case 0: { hack=false; break; } case 1: // Modify Time cout << "God Mode On\n!> "; // cin >> iValue; // nop_((PVOID)(0x409A7E), 3); // MemCopy(phandle, (PVOID)0x409A7E, &NOP, 1); WriteMem((DWORD)(0x00409A7E), (void*)NOP, sizeof NOP); if(GetLastError()) { cout << "Error: " << GetLastError() << endl; system("pause"); } break; default: cout << "ERROR!\n"; break; } Sleep(100); } system("pause"); return 0; } This is suppose to NOP the DEC function that is 3 bytes long preventing me from losing lives. However each time I try it, it crashes the hack and says I had a access violation. I tried to look up the reasons and most of them dealt with with the size of the location I'm writing to and what I'm copying from. Otherwise, I have absolutely no idea. Any help would be nice. The game is GunRoar and the base address "0x409A7E" is where the DEC function is.

    Read the article

  • New to programming

    - by Shaun
    I have a form (Quote) with an auto-number ID, on the form at the moment are two subforms that show different items (sub 1 shows partition modules sub 2 shows partition abutments) both forms use the same parts tables to build them. Both forms are linked to the quote form using the ID. All works well until the forms is refreshed or re-loaded, subform 1 shows the module names and quantities and blank spaces for the abutment names but shows the quantiews for the abutments, the reverse of this is shown in the abutments subform 2. When the lists for the variuos types and the detailed parts lists are printed they are correct. This seems to be only a visual problem. All based on Access 2003. Subform 1 SELECT Quote_Modules.ModuleID, Quote_Modules.QuoteID, Quote_Modules.ModuleDescription, Quote_Modules.ModuleQty, Quote.Style, Quote.Trim FROM Quote INNER JOIN Quote_Modules ON Quote.QuoteID=Quote_Modules.QuoteID ORDER BY Quote_Modules.ModuleID; Subform 2 SELECT Quote_Modules.ModuleID, Quote_Modules.QuoteID, Quote_Modules.ModuleDescription, Quote_Modules.ModuleQty, Quote.Style, Quote.Trim FROM Quote INNER JOIN Quote_Modules ON Quote.QuoteID=Quote_Modules.QuoteID ORDER BY Quote_Modules.ModuleID;

    Read the article

  • Should a Trim method generally in the Data Access Layer or with in the Domain Layer?

    - by jpierson
    I'm dealing with a database that contains data with inconsistencies such as white leading and trailing white space. In general I see a lot of developers practice defensive coding by trimming almost all strings that come from the database that may have been entered by a user at some point. In my oppinoin it is better to do such formating before data is persisted so that it is done only once and then the data can be in a consistent and reliable state. Unfortunatley this is not the case however which leads me to the next best solution, using a Trim method. If I trim all data as part of my data access layer then I don't have to concern myself with defensive trimming within the business objects of my domain layer. If I instead put the trimming responsibility in my business objects, such as with set accessors of my C# properties, I should get the same net results however the trim will be operating on all values assigned to my business objects properties not just the ones that come from the inconsistent database. I guess as a somewhat philisophical question that may determine the answer I could ask "Should the domain later be responsible for defensive/coercive formatting of data?" Would it make sense to have a set accessor for a PhoneNumber property on a business object accept a unformatted or formatted string and then attempt to format it as required or should this responsibility be pushed to the presentation and data access layers leaving the domain layer more strict in the type of data that it will accept? I think this may be the more fundamental question. Update: Below are a few links that I thought I should share about the topic of data cleansing. Information service patterns, Part 3: Data cleansing pattern LINQ to SQL - Format a string before saving? How to trim values using Linq to Sql?

    Read the article

  • Cisco access list logging. Why is there a difference between IPv4 and IPv6?

    - by growse
    I've got a Cisco 877 router. I've got an IPv4 access list and an IPv6 access list set up and configured similar to this: interface Dialer1 ... ip access-group INTERET-IN ipv6 traffic-filter IPV6-IN Each of these access lists has a final rule of deny ip/ipv6 any any log. However, in my syslog I notice that there's a difference in formatting between the two types of entries. IPv4 will say: %SEC-6-IPACCESSLOGP: list INTERNET-IN denied udp 88.89.209.63(137) -> 1.2.3.4(137), 1 packet Whereas the IPv6 list will say %IPV6_ACL-6-ACCESSLOGNP: list IPV6-IN/240 denied 59 2001:0:5EF5:79FD:14F9:B773:3EBA:3EE3 (Dialer1) -> 2001:800:1000:0::1, 8 packets Both have broadly the same information, but the IPv6 log entry is missing the protocol type and port, both of which are very useful if I'm trying to troubleshoot connectivity. Why is this? How do I get IPv6 deny logs to display the protocol and port used, if any?

    Read the article

< Previous Page | 63 64 65 66 67 68 69 70 71 72 73 74  | Next Page >