Search Results

Search found 8684 results on 348 pages for 'nunit console'.

Page 75/348 | < Previous Page | 71 72 73 74 75 76 77 78 79 80 81 82  | Next Page >

  • Dispose, when is it called?

    - by Snake
    Consider the following code: namespace DisposeTest { using System; class Program { static void Main(string[] args) { Console.WriteLine("Calling Test"); Test(); Console.WriteLine("Call to Test done"); } static void Test() { DisposeImplementation di = new DisposeImplementation(); } } internal class DisposeImplementation : IDisposable { ~DisposeImplementation() { Console.WriteLine("~ in DisposeImplementation instance called"); } public void Dispose() { Console.WriteLine("Dispose in DisposeImplementation instance called"); } } } The Dispose just never get's called, even if I put a wait loop after the Test(); invocation. So that quite sucks. I want to write a class that is straightforward and very easy to use, to make sure that every possible resource is cleaned up. I don't want to put that responsibilty to the user of my class. Possible solution: use using, or call Dispose myself(basicly the same). Can I force the user to use a using? Or can I force the dispose to be called? Calling GC.Collect(); after Test(); doesn't work either. Putting di to null doesn't invoke Dispose either. The Deconstructor DOES work, so the object get's deconstructed when it exits Test()

    Read the article

  • Serialport List Read problem and NullReferenceException?

    - by Plumbum7
    Hello everybody, Using Microsoft VC# 2008 Express (little fact about me : non experience in c#, programskills further very beginnerlevel. This peace op program is to communicate with Zigbee switching walloutlets (switching, status info). and is downloaded from http://plugwiselib.codeplex.com/SourceControl/list/changesets The problem: NullRefferenceException was UnHandled private void port_DataReceived(object sender, SerialDataReceivedEventArgs e) {// Event for receiving data string txt = port.ReadExisting(); Console.WriteLine(txt); List<PlugwiseMessage> msg = reader.Read (Regex.Split (txt, "\r\n" )); //Console.WriteLine( msg ); DataReceived(sender, new System.EventArgs(), msg); VC# Marks the last line and says msg is empty. so i looked further. Msg come's from txt text is filled with "000002D200C133E1\r\nPutFifoUnicast 40 : Handle 722 :"< so it goes wrong in or reader.Read or in the List so i looked further: public List<PlugwiseMessage> Read(string[] serialData) { Console.WriteLine(serialData); List<PlugwiseMessage> output = new List<PlugwiseMessage>(); Console.WriteLine(output); Both (serialData) as (output); are empty. So can i assume that the problem is in: Read(string[] serialData) But now the questions, Is Read(string[] serialData) something which is a Windows.Refence or is is from a Method ? and IF this is so is this then reader.READ (how can i find this)? (answered my own question proberly)(method reader)(private PlugwiseReader reader) So why isn't is working trough the serialData ? or is it the List<PlugwiseMessage> part, but i have no idea how it is filled can sombody help me ?

    Read the article

  • lock statement not working when there is a loop inside it?

    - by Ngu Soon Hui
    See this code: public class multiply { public Thread myThread; public int Counter { get; private set; } public string name { get; private set; } public void RunConsolePrint() { lock(this) { RunLockCode("lock"); } } private void RunLockCode(string lockCode) { Console.WriteLine("Now thread "+lockCode+" " + name + " has started"); for (int i = 1; i <= Counter; i++) { Console.WriteLine(lockCode+" "+name + ": count has reached " + i + ": total count is " + Counter); } Console.WriteLine("Thread " + lockCode + " " + name + " has finished"); } public multiply(string pname, int pCounter) { name = pname; Counter = pCounter; myThread = new Thread(new ThreadStart(RunConsolePrint)); } } And this is the test run code: static void Main(string[] args) { int counter = 50; multiply m2 = new multiply("Second", counter); multiply m1 = new multiply("First", counter); m1.myThread.Start(); m2.myThread.Start(); Console.ReadLine(); } I would expect that m2 must execute from start to finish before m1 starts executing, or vice versa, because of the lock statement. But the result I found was the call to lock first and lock second was intermingled together, i.e., something like this Now thread lock First has started Now thread lock Second has started lock First: Count has reached 1: total count is 50 lock First: Count has reached 2: total count is 50 lock Second: Count has reached 1: total count is 50 What did I do wrong?

    Read the article

  • Javascript Global Variable in Array

    - by user1387727
    My question may be very easy to lots of people, but I am new to Javascript. I really do not know what is wrong with the following codes. var newValue = 1; function getCurrentAmount() { return [newValue,2,3]; } var result = getCurrentAmount(); console.log(result[0] + "" + result[1] + result[2]); In the above code, the result shown in console is: undefined23 Why is the result not "123"? I am trying to use global variable because I want to increment newValue by 1 each time when the function is called. I want something like the following: var newValue = 1; function getCurrentAmount() { newValue ++; return [newValue,2,3]; } setInterval(function(){ var result = getCurrentAmount(); console.log(result[0] + "" + result[1] + result[2]); }, 1000); Also, I just tired the following codes and it works as expected. var newValue =1; function test() { newValue ++; return newValue; } console.log(test()); So I think the problem is about the Array. I hope my question is clear enough. Thanks in advance.

    Read the article

  • Generating new tasks in a foreach loop

    - by Scott Chamberlain
    I know from the codeing guidlines that I have read you should not do for (int i = 0; i < 5; i++) { Task.Factory.StartNew(() => Console.WriteLine(i)); } Console.ReadLine(); as it will write 5 5's, I understand that and I think i understand why it is happening. I know the solution is just to do for (int i = 0; i < 5; i++) { int localI = i; Task.Factory.StartNew(() => Console.WriteLine(localI)); } Console.ReadLine(); However is something like this ok to do? Task currentTask = myFirstTask; currentTask.Start(); foreach (Task task in _TaskList) { currentTask.ContinueWith((antecendent) => { if(antecendent.IsCompleated) { task.Start(); } else //do error handling; }); currentTask = task; } } or do i need to do this? Task currentTask = myFirstTask; foreach (Task task in _TaskList) { Task localTask = task; currentTask.ContinueWith((antecendent) => { if(antecendent.IsCompleated) { localTask.Start(); } else //do error handling; }); currentTask = task; }

    Read the article

  • Passing a string to a function in C++

    - by Chef Flambe
    I want to pass a string like "Celcius" into a function that I have but I keep getting errors tossed back at me from the Function. System::Console::WriteLine' : none of the 19 overloads could convert all the argument types I figure I just have something simple wrong. Can someone point out my mistake please? Using MS Visual C++ 2010 I've posted the offending code. The other functions (not posted) work fine. void PrintResult( double result, std::string sType ); // Print result and string // to the console //============================================================================================= // start of main //============================================================================================= void main( void ) { ConsoleKeyInfo CFM; // Program Title and Description ProgramDescription(); // Menu Selection and calls to data retrieval/calculation/result Print CFM=ChooseFromMenu(); switch(CFM.KeyChar) // ************************************************************ { //* case '1' : PrintResult(F2C(GetTemperature()),"Celsius"); //* break; //* //* case '2' : PrintResult(C2F(GetTemperature()),"Fahrenheit"); //* break; //* //* default : Console::Write("\n\nSwitch : Case !!!FAILURE!!!"); //* } //************************************************************ system("pause"); return; } //Function void PrintResult( double result, std::string sType ) { Console::WriteLine("\n\nThe converted temperature is {0:F2} degrees {1}\n\n",result,sType); return; }

    Read the article

  • jQuery: Is it possible to assign a DOM element to a variable for later use?

    - by Braxo
    I'm working on a project that is using jQuery, which I'm much more familiar with Mootools. I'll start with my code first. var customNamespace = { status: 'closed', popup: $('#popup'), showPopup: function() { // ... } } $(document).ready(function(){ console.log($('#popup')); console.log(customNamespace.popup); console.log($(customNamespace.popup)); $('#popup').fadeIn('slow'); (customNamespace.popup).fadeIn('slow'); $(customNamespace.popup).fadeIn('slow'); }); My goal is to not have jQuery traverse the DOM everytime I want to do something with the #popup div, so I wanted to save it to a variable to use it throughout my script. When the page loads, the console prints out the object 3 times as I would expect, so I assumed that for each method, the fadeIn would just work. But it doesn't, only $('#popup').fadeIn('slow'); Actually fades in the div. Even if I remove my namespace hash, and just save the object to a global variable, and do a var globalVariable = $('#popup'); . . . globalVariable.fadeIn('slow'); Also does not work as I thought it would. Can jQuery do what I am trying to do?

    Read the article

  • Why do I get 'Connection refused - connect(2)' for some models?

    - by Will
    I have a rails application running for the past 90 days that suddenly stopped working. Debugging the problem I found that I can read from the DB but not write to it. At least for certain models. There is one model that I can save whereas all others return Connection refused - connect(2) when I attempt to save them. They all used to work fine last month. I have no idea how to determine what the problem may be. Unfortunately I do not have access to the actual server remotely right now so I am limited in my debugging ability. I was able to get some non-tech people to run simple commands though that may help identify my problem. I will also be getting access tomorrow at some point. 1 Check from the console ./script/console >> a = Post.last.clone => #<Post id: nil, title: "test"... >> a.ex_id = 7 >> a.save Connection refused - connect(2) ... ... >> b = Story.last.console => #<Story id: nil, title: "test"... >> a.ex_id = 7 >> a.save => true I am not sure why this works for story and not post. This is consistent over many tests. 2 Check from mysql ./script/dbconsole -p mysql> INSERT INTO Posts (`title`,`body`, `ex_id`) SELECT `title`, `body`, 7 FROM Posts WHERE ID = 1; Query OK, 1 row affected (0.01 sec) Records: 1 Duplicates: 0 Warnings: 0 And as you can see I am able to write to the table with the same credientials that Rails uses? Does anyone know why I get connection refused in the console?

    Read the article

  • Class Inside Structure

    - by Knvn
    Could some one please explain, What happens when a reference type is defined inside the value type. I write the following code: namespace ClassInsideStruct { class ClassInsideStruct { static void Main(string[] args) { ValueType ObjVal = new ValueType(10); ObjVal.Display(); ValueType.ReferenceType ObjValRef = new ValueType.ReferenceType(10); ObjValRef.Display(); Test(ObjVal, ObjValRef); ObjVal.Display(); ObjValRef.Display(); Console.ReadKey(); } private static void Test(ValueType v, ValueType.ReferenceType r) { v.SValue = 50; r.RValue = 50; } } struct ValueType { int StructNum; ReferenceType ObjRef; public ValueType(int i) { StructNum = i; ObjRef = new ReferenceType(i); } public int SValue { get { return StructNum; } set { StructNum = value; ObjRef.RValue = value; } } public void Display() { Console.WriteLine("ValueType: " + StructNum); Console.Write("ReferenceType Inside ValueType Instance: "); ObjRef.Display(); } public class ReferenceType { int ClassNum; public ReferenceType(int i) { ClassNum = i; } public void Display() { Console.WriteLine("Reference Type: " + ClassNum); } public int RValue { get { return ClassNum; } set { ClassNum = value; } } } } } Which outputs: ValueType: 10 ReferenceType Inside ValueType Instance: Reference Type: 10 Reference Type: 10 ValueType: 10 ReferenceType Inside ValueType Instance: Reference Type: 50 Reference Type: 50 I'm curious to know, after calling the method Test(ObjVal, ObjValRef), how the values of ReferenceType is changed to 50 which resides inside the ValueType who's value is not changed?

    Read the article

  • OFM 11g: OAM SSO for Forms and ADF Faces

    - by olaf.heimburger
    In my blog entry OFM 11g: Implementing OAM SSO with Forms we set the foundation for providing a complete Single Sign-On solution based on Oracle Access Manager (OAM). This foundation should now be used to combine Forms 11g and ADF Faces 11g applications with a transparent login. The Beginning Before we start, lets re-consider the requirements to achieve the ultimate goal. These are:- Access to the Forms 11g Application must be authenticated by OAM (protected). Access to the ADF Faces 11g Application must be authenticated by OAM (protected). Switching from one application to the other should not result in a re-authentication (aka single sign-on). User identity should be availble to the application without any extra work in the application code. All these are the common requirements for a single sign-on solution. The challenge here is that Forms relies on Oracle AS SSO (OSSO or "the old SSO") while ADF Faces is quite open and can be protected by Oracle AS SSO and Oracle Access Manager SSO (OAM SSO or "the modern SSO"). Both application types can use their own login mechanism. The Forms 11g Application To demonstrate the SSO functionality, we use the standard Forms test (/forms/frmservlet?form=test.fmx). Although this shows nothing specific in the Forms application, it is good enough to demonstrate that it is protected. The ADF Faces 11g Application With ADF 11g you can develop quite a number of useful Faces based applications. Among many features, it comes with the ADF Security feature that provides you with functionality to protect your pages, regions, and even TaskFlows from un-authenticated usage in a declarative way.To demonstrate that functionality a sample application with different access levels plus a login dialog is used. This application comes with a publc page that has protected content (a button). Once you are authenticated for the application, the protected content and some personalisation (the users name) is shown. Protecting Forms 11g As already explained in the OFM 11g: Implementing OAM SSO with Forms, the easiest way to protect a Forms application is to configure it as a OSSO partner application, setup mod_osso, test it, migrate OSSO to OAM SSO with the Upgrade Agent, reconfigure mod_osso, and you are done.Sort of. By default the OAM is configured to run in co-exist mode. This means that a user has to re-authenticate to the Forms application when logged into an OAM SSO application before. To avoid this, you must disable the co-exist mode, for example by using WLST and issue the disableCoexistMode on the OAM server. Protecting ADF Faces 11g To protect an ADF Faces 11g application we have to consider two scenarios: Use a HTTPD server in front of WLS Use WLS without a HTTPD server Both scenarios have their pro's and cons' and we won't get into details and just describe how to configure both. Scenario 1: HTTPD Server with WLS In this scenario we have to setup the environment in some steps:- Configure a WebGate at OAMThis configuration can be done through the OAM console or by a script. No matter which way you choose, the WebGate configuration files will be created for you. Install the OAM WebGate into an HTTPD serverThe type of webgate you need to install depends on you HTTPD server. With Oracle HTTP Server 11g you can use the latest OAM 11g WebGate. With other HTTPD servers you must resort to OAM 10g WebGates. A OAM 11g WebGate can use the pre-created configuration files supplied during the WebGate configuration at OAM. An OAM 10g WebGate asks for the specific configuration and verifies it during installation. Configure the WLS plugin to forward the requests to WLSAgain, depending on your HTTPD Server you have different plugins to forward requests to WLS. With OHS 11g you can use the pre-installed mod_wl_ohs plugin. Its configuration is quite simple and straightforward. Configure an OAM SSPI Provider as a IdentityAsserter in WLS to retrieve the user identifierThis configuration is quite important as it retrieves the user identifier for the next step. If you have a SOA Suite installation within your OFM_HOME, the necessary software is already installed and you only need to setup your Security Realm within WLS.You can do this by pointing your browser to the WLS Console, log in as administrator, select the Security Realm (usually myrealm), and select Providers. We add the OAMIdentityAsserter as the first SSPI Provider. It is important that the Control Flag is set to SUFFICIENT. Every other configuration can be left as is, no changes are necessary here. Configure an OAM Identity Provider to get the real user identityIn OFM 11g: Implementing OAM SSO with Forms we have configured an OID as Identity Store. To get the user identity we need to configure the same OID as an SSPI Provider for WLS. This will retrieve the real user information from OID and creates the JAAS Subject and Principals to be used by any application within WLS.Again, you can do this by pointing your browser to the WLS Console, log in as administrator, select the Security Realm (usually myrealm), and select Providers. Now add the OIDAuthenticator as the second SSPI Provider. It is important that the Control Flag is set to OPTIONAL. After we saved this setup, we need to configure this provider by setting the Provider Specific details to access OID. Scenario 2: WLS only This scenario is a bit easier but requires more work in the WLS setup:- Configure a WebGate at OAMThis configuration can be done through the OAM console or by a script. No matter which way you choose, the WebGate configuration files will be created for you. Configure the OAM SSPI Provider as IdentityAuthenticator to authenticate and set the user identifierWhen using the OAM SSPI Provider as OAMAuthenticator we create it with the Control Flag as SUFFICIENT. Afte saving it, the Provider Specific settings must be configured to allow the OAM SSPI Provider to connect to the OAM Server. Configure an OAM Identity Provider to get the real user identity providerAgain, you can do this by pointing your browser to the WLS Console, log in as administrator, select the Security Realm (usually myrealm), and select Providers. Now add the OIDAuthenticator as the second SSPI Provider. It is important that the Control Flag is set to OPTIONAL. After we saved this setup, we need to configure this provider by setting the Provider Specific details to access OID. Configure ADF 11g Application for OAM Actually, there are no changes to be made within the ADF application. We only need to add the value CLIENT_CERT to the <auth-mode> tag in the <login-config> tag in the web.xml file. Testing To test the configuration, simply point your browser to one of both appliction URLs. OAM should kick in and redirect you to the OAM Login page. After you have entered the correct credentials, access to the URLs is granted and you will see the application. Enjoy!

    Read the article

  • Quartz.Net Windows Service Configure Logging

    - by Tarun Arora
    In this blog post I’ll be covering, Logging for Quartz.Net Windows Service 01 – Why doesn’t Quartz.Net Windows Service log by default 02 – Configuring Quartz.Net windows service for logging to eventlog, file, console, etc 03 – Results: Logging in action If you are new to Quartz.Net I would recommend going through, A brief Introduction to Quartz.net Walkthrough of Installing & Testing Quartz.Net as a Windows Service Writing & Scheduling your First HelloWorld job with Quartz.Net   01 – Why doesn’t Quartz.Net Windows Service log by default If you are trying to figure out why… The Quartz.Net windows service isn’t logging The Quartz.Net windows service isn’t writing anything to the event log The Quartz.Net windows service isn’t writing anything to a file How do I configure Quartz.Net windows service to use log4Net How do I change the level of logging for Quartz.Net Look no further, This blog post should help you answer these questions. Quartz.NET uses the Common.Logging framework for all of its logging needs. If you navigate to the directory where Quartz.Net Windows Service is installed (I have the service installed in C:\Program Files (x86)\Quartz.net, you can find out the location by looking at the properties of the service) and open ‘Quartz.Server.exe.config’ you’ll see that the Quartz.Net is already set up for logging to ConsoleAppender and EventLogAppender, but only ‘ConsoleAppender’ is set up as active. So, unless you have the console associated to the Quartz.Net service you won’t be able to see any logging. <log4net> <appender name="ConsoleAppender" type="log4net.Appender.ConsoleAppender"> <layout type="log4net.Layout.PatternLayout"> <conversionPattern value="%d [%t] %-5p %l - %m%n" /> </layout> </appender> <appender name="EventLogAppender" type="log4net.Appender.EventLogAppender"> <layout type="log4net.Layout.PatternLayout"> <conversionPattern value="%d [%t] %-5p %l - %m%n" /> </layout> </appender> <root> <level value="INFO" /> <appender-ref ref="ConsoleAppender" /> <!-- uncomment to enable event log appending --> <!-- <appender-ref ref="EventLogAppender" /> --> </root> </log4net> Problem: In the configuration above Quartz.Net Windows Service only has ConsoleAppender active. So, no logging will be done to EventLog. More over the RollingFileAppender isn’t setup at all. So, Quartz.Net will not log to an application trace log file. 02 – Configuring Quartz.Net windows service for logging to eventlog, file, console, etc Let’s change this behaviour by changing the config file… In the below config file, I have added the RollingFileAppender. This will configure Quartz.Net service to write to a log file. (<appender name="GeneralLog" type="log4net.Appender.RollingFileAppender">) I have specified the location for the log file (<arg key="configFile" value="Trace/application.log.txt"/>) I have enabled the EventLogAppender and RollingFileAppender to be written to by Quartz. Net windows service Changed the default level of logging from ‘Info’ to ‘All’. This means all activity performed by Quartz.Net Windows service will be logged. You might want to tune this back to ‘Debug’ or ‘Info’ later as logging ‘All’ will produce too much data to the logs. (<level value="ALL"/>) Since I have changed the logging level to ‘All’, I have added applicationSetting to remove logging log4Net internal debugging. (<add key="log4net.Internal.Debug" value="false"/>) <?xml version="1.0" encoding="utf-8" ?> <configuration> <configSections> <section name="quartz" type="System.Configuration.NameValueSectionHandler, System, Version=1.0.5000.0,Culture=neutral, PublicKeyToken=b77a5c561934e089" /> <section name="log4net" type="log4net.Config.Log4NetConfigurationSectionHandler, log4net" /> <sectionGroup name="common"> <section name="logging" type="Common.Logging.ConfigurationSectionHandler, Common.Logging" /> </sectionGroup> </configSections> <common> <logging> <factoryAdapter type="Common.Logging.Log4Net.Log4NetLoggerFactoryAdapter, Common.Logging.Log4net"> <arg key="configType" value="INLINE" /> <arg key="configFile" value="Trace/application.log.txt"/> <arg key="level" value="ALL" /> </factoryAdapter> </logging> </common> <appSettings> <add key="log4net.Internal.Debug" value="false"/> </appSettings> <log4net> <appender name="ConsoleAppender" type="log4net.Appender.ConsoleAppender"> <layout type="log4net.Layout.PatternLayout"> <conversionPattern value="%d [%t] %-5p %l - %m%n" /> </layout> </appender> <appender name="EventLogAppender" type="log4net.Appender.EventLogAppender"> <layout type="log4net.Layout.PatternLayout"> <conversionPattern value="%d [%t] %-5p %l - %m%n" /> </layout> </appender> <appender name="GeneralLog" type="log4net.Appender.RollingFileAppender"> <file value="Trace/application.log.txt"/> <appendToFile value="true"/> <maximumFileSize value="1024KB"/> <rollingStyle value="Size"/> <layout type="log4net.Layout.PatternLayout"> <conversionPattern value="%d{HH:mm:ss} [%t] %-5p %c - %m%n"/> </layout> </appender> <root> <level value="ALL" /> <appender-ref ref="ConsoleAppender" /> <appender-ref ref="EventLogAppender" /> <appender-ref ref="GeneralLog"/> </root> </log4net> </configuration>   Note – Please ensure you restart the Quartz.Net Windows service for the config changes to be picked up by the service   03 – Results: Logging in action Once you start the Quartz.Net Windows Service up, the logging should be initiated to write all activities in the Console, EventLog and File… See screen shots below… Figure – Quartz.Net Windows Service logging all activity to the event log Figure – Quartz.Net Windows Service logging all activity to the application log file Where is the output from log4Net ConsoleAppender? As a default behaviour, the console isn't available in windows services, web services, windows forms. The output will simply be dismissed. Unless you are running the process interactively. Which you can do by firing up Quartz.Server.exe –i to see the output   This was fourth in the series of posts on enterprise scheduling using Quartz.net, in the next post I’ll be covering troubleshooting why a scheduled task hasn’t fired on Quartz.net windows service. All Quartz.Net specific blog posts can listed here. Thank you for taking the time out and reading this blog post. If you enjoyed the post, remember to subscribe to http://feeds.feedburner.com/TarunArora. Stay tuned!

    Read the article

  • Integrating Coherence & Java EE 6 Applications using ActiveCache

    - by Ricardo Ferreira
    OK, so you are a developer and are starting a new Java EE 6 application using the most wonderful features of the Java EE platform like Enterprise JavaBeans, JavaServer Faces, CDI, JPA e another cool stuff technologies. And your architecture need to hold piece of data into distributed caches to improve application's performance, scalability and reliability? If this is your current facing scenario, maybe you should look closely in the solutions provided by Oracle WebLogic Server. Oracle had integrated WebLogic Server and its champion data caching technology called Oracle Coherence. This seamless integration between this two products provides a comprehensive environment to develop applications without the complexity of extra Java code to manage cache as a dependency, since Oracle provides an DI ("Dependency Injection") mechanism for Coherence, the same DI mechanism available in standard Java EE applications. This feature is called ActiveCache. In this article, I will show you how to configure ActiveCache in WebLogic and at your Java EE application. Configuring WebLogic to manage Coherence Before you start changing your application to use Coherence, you need to configure your Coherence distributed cache. The good news is, you can manage all this stuff without writing a single line of code of XML or even Java. This configuration can be done entirely in the WebLogic administration console. The first thing to do is the setup of a Coherence cluster. A Coherence cluster is a set of Coherence JVMs configured to form one single view of the cache. This means that you can insert or remove members of the cluster without the client application (the application that generates or consume data from the cache) knows about the changes. This concept allows your solution to scale-out without changing the application server JVMs. You can growth your application only in the data grid layer. To start the configuration, you need to configure an machine that points to the server in which you want to execute the Coherence JVMs. WebLogic Server allows you to do this very easily using the Administration Console. In this example, I will call the machine as "coherence-server". Remember that in order to the machine concept works, you need to ensure that the NodeManager are being executed in the target server that the machine points to. The NodeManager executable can be found in <WLS_HOME>/server/bin/startNodeManager.sh. The next thing to do is to configure a Coherence cluster. In the WebLogic administration console, go to Environment > Coherence Clusters and click in "New". Call this Coherence cluster of "my-coherence-cluster". Click in next. Specify a valid cluster address and port. The Coherence members will communicate with each other through this address and port. Our Coherence cluster are now configured. Now it is time to configure the Coherence members and add them to this cluster. In the WebLogic administration console, go to Environment > Coherence Servers and click in "New". In the field "Name" set to "coh-server-1". In the field "Machine", associate this Coherence server to the machine "coherence-server". In the field "Cluster", associate this Coherence server to the cluster named "my-coherence-cluster". Click in "Finish". Start the Coherence server using the "Control" tab of WebLogic administration console. This will instruct WebLogic to start a new JVM of Coherence in the target machine that should join the pre-defined Coherence cluster. Configuring your Java EE Application to Access Coherence Now lets pass to the funny part of the configuration. The first thing to do is to inform your Java EE application which Coherence cluster to join. Oracle had updated WebLogic server deployment descriptors so you will not have to change your code or the containers deployment descriptors like application.xml, ejb-jar.xml or web.xml. In this example, I will show you how to enable DI ("Dependency Injection") to a Coherence cache from a Servlet 3.0 component. In the WEB-INF/weblogic.xml deployment descriptor, put the following metadata information: <?xml version="1.0" encoding="UTF-8"?> <wls:weblogic-web-app xmlns:wls="http://xmlns.oracle.com/weblogic/weblogic-web-app" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://java.sun.com/xml/ns/javaee http://java.sun.com/xml/ns/javaee/web-app_2_5.xsd http://xmlns.oracle.com/weblogic/weblogic-web-app http://xmlns.oracle.com/weblogic/weblogic-web-app/1.4/weblogic-web-app.xsd"> <wls:context-root>myWebApp</wls:context-root> <wls:coherence-cluster-ref> <wls:coherence-cluster-name>my-coherence-cluster</wls:coherence-cluster-name> </wls:coherence-cluster-ref> </wls:weblogic-web-app> As you can see, using the "coherence-cluster-name" tag, we are informing our Java EE application that it should join the "my-coherence-cluster" when it loads in the web container. Without this information, the application will not be able to access the predefined Coherence cluster. It will form its own Coherence cluster without any members. So never forget to put this information. Now put the coherence.jar and active-cache-1.0.jar dependencies at your WEB-INF/lib application classpath. You need to deploy this dependencies so ActiveCache can automatically take care of the Coherence cluster join phase. This dependencies can be found in the following locations: - <WLS_HOME>/common/deployable-libraries/active-cache-1.0.jar - <COHERENCE_HOME>/lib/coherence.jar Finally, you need to write down the access code to the Coherence cache at your Servlet. In the following example, we have a Servlet 3.0 component that access a Coherence cache named "transactions" and prints into the browser output the content (the ammount property) of one specific transaction. package com.oracle.coherence.demo.activecache; import java.io.IOException; import javax.annotation.Resource; import javax.servlet.ServletException; import javax.servlet.annotation.WebServlet; import javax.servlet.http.HttpServlet; import javax.servlet.http.HttpServletRequest; import javax.servlet.http.HttpServletResponse; import com.tangosol.net.NamedCache; @WebServlet("/demo/specificTransaction") public class TransactionServletExample extends HttpServlet { @Resource(mappedName = "transactions") NamedCache transactions; protected void doGet(HttpServletRequest request, HttpServletResponse response) throws ServletException, IOException { int transId = Integer.parseInt(request.getParameter("transId")); Transaction transaction = (Transaction) transactions.get(transId); response.getWriter().println("<center>" + transaction.getAmmount() + "</center>"); } } Thats it! No more configuration is necessary and you have all set to start producing and getting data to/from Coherence. As you can see in the example code, the Coherence cache are treated as a normal dependency in the Java EE container. The magic happens behind the scenes when the ActiveCache allows your application to join the defined Coherence cluster. The most interesting thing about this approach is, no matter which type of Coherence cache your are using (Distributed, Partitioned, Replicated, WAN-Remote) for the client application, it is just a simple attribute member of com.tangosol.net.NamedCache type. And its all managed by the Java EE container as an dependency. This means that if you inject the same dependency (the Coherence cache named "transactions") in another Java EE component (JSF managed-bean, Stateless EJB) the cache will be the same. Cool isn't it? Thanks to the CDI technology, we can extend the same support for non-Java EE standards components like simple POJOs. This means that you are not forced to only use Servlets, EJBs or JSF in order to inject Coherence caches. You can do the same approach for regular POJOs created for you and managed by lightweight containers like Spring or Seam.

    Read the article

  • How to install Oracle Weblogic Server using OS-specific Package installer?(Linux/Solaris)

    - by PratikS -- Oracle
    Note: OS-specific Package installer As the name suggests the installer is platform specific. It is meant for installation with a 32bit JVM only. Both SUN and JROCKIT 32 bit JDKs come bundled with "OS-specific Package installer", so no need to install the JDK in advance. There are three different ways of installing Oracle Weblogic Server: Graphical mode Console mode Silent mode For Linux/Solaris: Steps to install OS-specific Package .bin installer(for Linux/Solaris) are almost same as windows except for the way we launch the installation.Installer: wls_<version>_<linux/solaris>32.bin (E.g. wls1036_linux32.bin/wls1036_solaris32.bin) 1) Graphical mode: Log in to the target UNIX system. Go to the directory that contains the installation program.(Make sure GUI is enabled or else it will default to console mode) Launch the installation by entering the following commands: [weblogic@pratik ~]$ pwd/home/oracle[weblogic@pratik ~]$ cd WLSInstallers/[weblogic@pratik WLSInstallers]$ ls -ltrtotal 851512-rw-rw-r-- 1 oracle oracle 871091023 Dec 22  2011 wls1036_linux32.bin[weblogic@pratik WLSInstallers]$ chmod a+x wls1036_linux32.bin[weblogic@pratik WLSInstallers]$ ls -ltrtotal 851512-rwxrwxr-x 1 oracle oracle 871091023 Dec 22  2011 wls1036_linux32.bin[weblogic@pratik WLSInstallers]$ ./wls1036_linux32.bin As soon as you run ./wls1036_linux32.bin with GUI enabled you would see the following screen: Rest of the screens and steps are similar to that of Graphical mode installation on windows, refer: How to install Oracle Weblogic Server using OS-specific Package installer?(Windows) 2) Console mode: Log in to the target UNIX system. Go to the directory that contains the installation program. Launch the installation by entering the following commands: [weblogic@pratik ~]$ pwd/home/oracle[weblogic@pratik ~]$ cd WLSInstallers/[weblogic@pratik WLSInstallers]$ ls -ltrtotal 851512-rw-rw-r-- 1 weblogic weblogic 871091023 Dec 22  2011 wls1036_linux32.bin[weblogic@pratik WLSInstallers]$ chmod a+x wls1036_linux32.bin[weblogic@pratik WLSInstallers]$ ls -ltrtotal 851512-rwxrwxr-x 1 weblogic weblogic 871091023 Dec 22  2011 wls1036_linux32.bin [weblogic@pratik WLSInstallers]$ ./wls1036_linux32.bin -mode=consoleExtracting 0%....................................................................................................100%<-------------------- Oracle Installer - WebLogic 10.3.6.0 ------------------->Welcome:--------This installer will guide you through the installation of WebLogic 10.3.6.0.Type "Next" or enter to proceed to the next prompt.  If you want to change data entered previously, type "Previous".  You may quit the installer at any time by typing "Exit".Enter [Exit][Next]> Next<-------------------- Oracle Installer - WebLogic 10.3.6.0 ------------------->Choose Middleware Home Directory:--------------------------------- ->1|* Create a new Middleware Home   2|/home/oracle/wls_12cEnter index number to select OR [Exit][Previous][Next]> Next<-------------------- Oracle Installer - WebLogic 10.3.6.0 ------------------->Choose Middleware Home Directory:---------------------------------    "Middleware Home" = [Enter new value or use default"/home/oracle/Oracle/Middleware"]Enter new Middleware Home OR [Exit][Previous][Next]> /home/oracle/WLS1036<-------------------- Oracle Installer - WebLogic 10.3.6.0 ------------------->Choose Middleware Home Directory:---------------------------------    "Middleware Home" = [/home/oracle/WLS1036]Use above value or select another option:    1 - Enter new Middleware Home    2 - Change to default [/home/oracle/Oracle/Middleware]Enter option number to select OR [Exit][Previous][Next]> Next<-------------------- Oracle Installer - WebLogic 10.3.6.0 ------------------->Register for Security Updates:------------------------------Provide your email address for security updates and  to initiate configuration manager.   1|Email:[]   2|Support Password:[]   3|Receive Security Update:[Yes]Enter index number to select OR [Exit][Previous][Next]> 3<-------------------- Oracle Installer - WebLogic 10.3.6.0 ------------------->Register for Security Updates:------------------------------Provide your email address for security updates and  to initiate configuration manager.    "Receive Security Update:" = [Enter new value or use default "Yes"]Enter [Yes][No]? No<-------------------- Oracle Installer - WebLogic 10.3.6.0 ------------------->Register for Security Updates:------------------------------Provide your email address for security updates and  to initiate configuration manager.    "Receive Security Update:" = [Enter new value or use default "Yes"]    ** Do you wish to bypass initiation of the configuration manager and    **  remain uninformed of critical security issues in your configuration?Enter [Yes][No]? Yes<-------------------- Oracle Installer - WebLogic 10.3.6.0 ------------------->Register for Security Updates:------------------------------Provide your email address for security updates and  to initiate configuration manager.   1|Email:[]   2|Support Password:[]   3|Receive Security Update:[No]Enter index number to select OR [Exit][Previous][Next]>Next<-------------------- Oracle Installer - WebLogic 10.3.6.0 ------------------->Register for Security Updates:------------------------------Provide your email address for security updates and  to initiate configuration manager.   1|Email:[]   2|Support Password:[]   3|Receive Security Update:[No]Enter index number to select OR [Exit][Previous][Next]> Next<-------------------- Oracle Installer - WebLogic 10.3.6.0 ------------------->Choose Install Type:--------------------Select the type of installation you wish to perform. ->1|Typical    |  Install the following product(s) and component(s):    | - WebLogic Server    | - Oracle Coherence   2|Custom    |  Choose software products and components to install and perform optional    |configuration.Enter index number to select OR [Exit][Previous][Next]> Next<-------------------- Oracle Installer - WebLogic 10.3.6.0 ------------------->Choose Product Installation Directories:----------------------------------------Middleware Home Directory: [/home/oracle/WLS1036]Product Installation Directories:   1|WebLogic Server: [/home/oracle/WLS1036/wlserver_10.3]   2|Oracle Coherence: [/home/oracle/WLS1036/coherence_3.7]Enter index number to select OR [Exit][Previous][Next]> Next<-------------------- Oracle Installer - WebLogic 10.3.6.0 ------------------->The following Products and JDKs will be installed:--------------------------------------------------    WebLogic Platform 10.3.6.0    |_____WebLogic Server    |    |_____Core Application Server    |    |_____Administration Console    |    |_____Configuration Wizard and Upgrade Framework    |    |_____Web 2.0 HTTP Pub-Sub Server    |    |_____WebLogic SCA    |    |_____WebLogic JDBC Drivers    |    |_____Third Party JDBC Drivers    |    |_____WebLogic Server Clients    |    |_____WebLogic Web Server Plugins    |    |_____UDDI and Xquery Support    |    |_____Evaluation Database    |_____Oracle Coherence    |    |_____Coherence Product Files    |_____JDKs         |_____SUN SDK 1.6.0_29         |_____Oracle JRockit 1.6.0_29 SDK    *Estimated size of installation: 1,276.0 MBEnter [Exit][Previous][Next]> Next<-------------------- Oracle Installer - WebLogic 10.3.6.0 ------------------->Installing files..0%          25%          50%          75%          100%[------------|------------|------------|------------][***************************************************]<-------------------- Oracle Installer - WebLogic 10.3.6.0 ------------------->Installing JDK....0%          25%          50%          75%          100%[------------|------------|------------|------------][***************************************************]Performing String Substitutions...<-------------------- Oracle Installer - WebLogic 10.3.6.0 ------------------->Configuring OCM...0%          25%          50%          75%          100%[------------|------------|------------|------------][***************************************************]Creating Domains...<-------------------- Oracle Installer - WebLogic 10.3.6.0 ------------------->Installation CompleteCongratulations! Installation is complete.Press [Enter] to continue or type [Exit]> [weblogic@pratik ~]$ Note: All the inputs are in Bold 3) Silent mode:              1) Log in to the target Unix system.             2) Create a silent.xml file that defines the configuration settings normally entered by a user during an interactive installation process, such as graphical-mode or console-mode installation. <?xml version="1.0" encoding="UTF-8"?><bea-installer>     <input-fields>        <data-value name="BEAHOME" value="/home/oracle/WLS1036" />        <data-value name="WLS_INSTALL_DIR" value="/home/oracle/WLS1036/wlserver_10.3" />        <data-value name="COMPONENT_PATHS" value="WebLogic Server|Oracle Coherence" />    </input-fields></bea-installer> <!-- Note: This sample silent.xml file is used to install all the components of WebLogic Server and Oracle Coherence. All the values in Bold are the variables. -->               3) Place the silent.xml file in the same directory as where the WebLogic Server Package installer is located.              4) Go to the directory that contains the installation program.              5) Start the installer as follows: [weblogic@pratik WLSInstallers]$ chmod a+x wls1036_linux32.bin[weblogic@pratik WLSInstallers]$ ls -ltrtotal 851516-rwxrwxr-x 1 weblogic weblogic 871091023 Dec 22  2011 wls1036_linux32.bin-rw-rw-r-- 1 weblogic weblogic       331 Jul  5 03:48 silent.xml[weblogic@pratik WLSInstallers]$ cat silent.xml<?xml version="1.0" encoding="UTF-8"?><bea-installer>        <input-fields>                <data-value name="BEAHOME" value="/home/oracle/WLS1036" />                <data-value name="WLS_INSTALL_DIR" value="/home/oracle/WLS1036/wlserver_10.3" />                <data-value name="COMPONENT_PATHS" value="WebLogic Server|Oracle Coherence" />        </input-fields></bea-installer>[weblogic@pratik WLSInstallers]$ ./wls1036_linux32.bin -mode=silenlent.xml -log=/home/oracle/WLSInstallers/install.logExtracting 0%....................................................................................................100%[weblogic@pratik WLSInstallers]$ -log=/home/oracle/WLSInstallers/install.log creates a installation log(install.log) under "/home/oracle/WLSInstallers/", when installation completes you will see the following printed in the log file: 2012-07-05 03:59:36,788 INFO  [WizardController] com.bea.plateng.wizard.silent.tasks.LogTask - The installation was successfull! For other configurable values in silent.xml refer: Values for the Sample silent.xml File for WebLogic Server Important links to Refer: Running the Installation Program in Graphical Mode Running the Installation Program in Console Mode Running the Installation Program in Silent Mode

    Read the article

  • Metro: Understanding CSS Media Queries

    - by Stephen.Walther
    If you are building a Metro style application then your application needs to look great when used on a wide variety of devices. Your application needs to work on tiny little phones, slates, desktop monitors, and the super high resolution displays of the future. Your application also must support portable devices used with different orientations. If someone tilts their phone from portrait to landscape mode then your application must still be usable. Finally, your Metro style application must look great in different states. For example, your Metro application can be in a “snapped state” when it is shrunk so it can share screen real estate with another application. In this blog post, you learn how to use Cascading Style Sheet media queries to support different devices, different device orientations, and different application states. First, you are provided with an overview of the W3C Media Query recommendation and you learn how to detect standard media features. Next, you learn about the Microsoft extensions to media queries which are supported in Metro style applications. For example, you learn how to use the –ms-view-state feature to detect whether an application is in a “snapped state” or “fill state”. Finally, you learn how to programmatically detect the features of a device and the state of an application. You learn how to use the msMatchMedia() method to execute a media query with JavaScript. Using CSS Media Queries Media queries enable you to apply different styles depending on the features of a device. Media queries are not only supported by Metro style applications, most modern web browsers now support media queries including Google Chrome 4+, Mozilla Firefox 3.5+, Apple Safari 4+, and Microsoft Internet Explorer 9+. Loading Different Style Sheets with Media Queries Imagine, for example, that you want to display different content depending on the horizontal resolution of a device. In that case, you can load different style sheets optimized for different sized devices. Consider the following HTML page: <!DOCTYPE html> <html xmlns="http://www.w3.org/1999/xhtml"> <head> <title>U.S. Robotics and Mechanical Men</title> <link href="main.css" rel="stylesheet" type="text/css" /> <!-- Less than 1100px --> <link href="medium.css" rel="stylesheet" type="text/css" media="(max-width:1100px)" /> <!-- Less than 800px --> <link href="small.css" rel="stylesheet" type="text/css" media="(max-width:800px)" /> </head> <body> <div id="header"> <h1>U.S. Robotics and Mechanical Men</h1> </div> <!-- Advertisement Column --> <div id="leftColumn"> <img src="advertisement1.gif" alt="advertisement" /> <img src="advertisement2.jpg" alt="advertisement" /> </div> <!-- Product Search Form --> <div id="mainContentColumn"> <label>Search Products</label> <input id="search" /><button>Search</button> </div> <!-- Deal of the Day Column --> <div id="rightColumn"> <h1>Deal of the Day!</h1> <p> Buy two cameras and get a third camera for free! Offer is good for today only. </p> </div> </body> </html> The HTML page above contains three columns: a leftColumn, mainContentColumn, and rightColumn. When the page is displayed on a low resolution device, such as a phone, only the mainContentColumn appears: When the page is displayed in a medium resolution device, such as a slate, both the leftColumn and the mainContentColumns are displayed: Finally, when the page is displayed in a high-resolution device, such as a computer monitor, all three columns are displayed: Different content is displayed with the help of media queries. The page above contains three style sheet links. Two of the style links include a media attribute: <link href="main.css" rel="stylesheet" type="text/css" /> <!-- Less than 1100px --> <link href="medium.css" rel="stylesheet" type="text/css" media="(max-width:1100px)" /> <!-- Less than 800px --> <link href="small.css" rel="stylesheet" type="text/css" media="(max-width:800px)" /> The main.css style sheet contains default styles for the elements in the page. The medium.css style sheet is applied when the page width is less than 1100px. This style sheet hides the rightColumn and changes the page background color to lime: html { background-color: lime; } #rightColumn { display:none; } Finally, the small.css style sheet is loaded when the page width is less than 800px. This style sheet hides the leftColumn and changes the page background color to red: html { background-color: red; } #leftColumn { display:none; } The different style sheets are applied as you stretch and contract your browser window. You don’t need to refresh the page after changing the size of the page for a media query to be applied: Using the @media Rule You don’t need to divide your styles into separate files to take advantage of media queries. You can group styles by using the @media rule. For example, the following HTML page contains one set of styles which are applied when a device’s orientation is portrait and another set of styles when a device’s orientation is landscape: <!DOCTYPE html> <html> <head> <meta charset="utf-8" /> <title>Application1</title> <style type="text/css"> html { font-family:'Segoe UI Semilight'; font-size: xx-large; } @media screen and (orientation:landscape) { html { background-color: lime; } p.content { width: 50%; margin: auto; } } @media screen and (orientation:portrait) { html { background-color: red; } p.content { width: 90%; margin: auto; } } </style> </head> <body> <p class="content"> Lorem ipsum dolor sit amet, consectetuer adipiscing elit. Maecenas porttitor congue massa. Fusce posuere, magna sed pulvinar ultricies, purus lectus malesuada libero, sit amet commodo magna eros quis urna. </p> </body> </html> When a device has a landscape orientation then the background color is set to the color lime and the text only takes up 50% of the available horizontal space: When the device has a portrait orientation then the background color is red and the text takes up 90% of the available horizontal space: Using Standard CSS Media Features The official list of standard media features is contained in the W3C CSS Media Query recommendation located here: http://www.w3.org/TR/css3-mediaqueries/ Here is the official list of the 13 media features described in the standard: · width – The current width of the viewport · height – The current height of the viewport · device-width – The width of the device · device-height – The height of the device · orientation – The value portrait or landscape · aspect-ratio – The ratio of width to height · device-aspect-ratio – The ratio of device width to device height · color – The number of bits per color supported by the device · color-index – The number of colors in the color lookup table of the device · monochrome – The number of bits in the monochrome frame buffer · resolution – The density of the pixels supported by the device · scan – The values progressive or interlace (used for TVs) · grid – The values 0 or 1 which indicate whether the device supports a grid or a bitmap Many of the media features in the list above support the min- and max- prefix. For example, you can test for the min-width using a query like this: (min-width:800px) You can use the logical and operator with media queries when you need to check whether a device supports more than one feature. For example, the following query returns true only when the width of the device is between 800 and 1,200 pixels: (min-width:800px) and (max-width:1200px) Finally, you can use the different media types – all, braille, embossed, handheld, print, projection, screen, speech, tty, tv — with a media query. For example, the following media query only applies to a page when a page is being printed in color: print and (color) If you don’t specify a media type then media type all is assumed. Using Metro Style Media Features Microsoft has extended the standard list of media features which you can include in a media query with two custom media features: · -ms-high-contrast – The values any, black-white, white-black · -ms-view-state – The values full-screen, fill, snapped, device-portrait You can take advantage of the –ms-high-contrast media feature to make your web application more accessible to individuals with disabilities. In high contrast mode, you should make your application easier to use for individuals with vision disabilities. The –ms-view-state media feature enables you to detect the state of an application. For example, when an application is snapped, the application only occupies part of the available screen real estate. The snapped application appears on the left or right side of the screen and the rest of the screen real estate is dominated by the fill application (Metro style applications can only be snapped on devices with a horizontal resolution of greater than 1,366 pixels). Here is a page which contains style rules for an application in both a snap and fill application state: <!DOCTYPE html> <html> <head> <meta charset="utf-8" /> <title>MyWinWebApp</title> <style type="text/css"> html { font-family:'Segoe UI Semilight'; font-size: xx-large; } @media screen and (-ms-view-state:snapped) { html { background-color: lime; } } @media screen and (-ms-view-state:fill) { html { background-color: red; } } </style> </head> <body> <p class="content"> Lorem ipsum dolor sit amet, consectetuer adipiscing elit. Maecenas porttitor congue massa. Fusce posuere, magna sed pulvinar ultricies, purus lectus malesuada libero, sit amet commodo magna eros quis urna. </p> </body> </html> When the application is snapped, the application appears with a lime background color: When the application state is fill then the background color changes to red: When the application takes up the entire screen real estate – it is not in snapped or fill state – then no special style rules apply and the application appears with a white background color. Querying Media Features with JavaScript You can perform media queries using JavaScript by taking advantage of the window.msMatchMedia() method. This method returns a MSMediaQueryList which has a matches method that represents success or failure. For example, the following code checks whether the current device is in portrait mode: if (window.msMatchMedia("(orientation:portrait)").matches) { console.log("portrait"); } else { console.log("landscape"); } If the matches property returns true, then the device is in portrait mode and the message “portrait” is written to the Visual Studio JavaScript Console window. Otherwise, the message “landscape” is written to the JavaScript Console window. You can create an event listener which triggers code whenever the results of a media query changes. For example, the following code writes a message to the JavaScript Console whenever the current device is switched into or out of Portrait mode: window.msMatchMedia("(orientation:portrait)").addListener(function (mql) { if (mql.matches) { console.log("Switched to portrait"); } }); Be aware that the event listener is triggered whenever the result of the media query changes. So the event listener is triggered both when you switch from landscape to portrait and when you switch from portrait to landscape. For this reason, you need to verify that the matches property has the value true before writing the message. Summary The goal of this blog entry was to explain how CSS media queries work in the context of a Metro style application written with JavaScript. First, you were provided with an overview of the W3C CSS Media Query recommendation. You learned about the standard media features which you can query such as width and orientation. Next, we focused on the Microsoft extensions to media queries. You learned how to use –ms-view-state to detect whether a Metro style application is in “snapped” or “fill” state. You also learned how to use the msMatchMedia() method to perform a media query from JavaScript.

    Read the article

  • TFS API Change WorkItem CreatedDate And ChangedDate To Historic Dates

    - by Tarun Arora
    There may be times when you need to modify the value of the fields “System.CreatedDate” and “System.ChangedDate” on a work item. Richard Hundhausen has a great blog with ample of reason why or why not you should need to set the values of these fields to historic dates. In this blog post I’ll show you, Create a PBI WorkItem linked to a Task work item by pre-setting the value of the field ‘System.ChangedDate’ to a historic date Change the value of the field ‘System.Created’ to a historic date Simulate the historic burn down of a task type work item in a sprint Explain the impact of updating values of the fields CreatedDate and ChangedDate on the Sprint burn down chart Rules of Play      1. You need to be a member of the Project Collection Service Accounts              2. You need to use ‘WorkItemStoreFlags.BypassRules’ when you instantiate the WorkItemStore service // Instanciate Work Item Store with the ByPassRules flag _wis = new WorkItemStore(_tfs, WorkItemStoreFlags.BypassRules);      3. You cannot set the ChangedDate         - Less than the changed date of previous revision         - Greater than current date Walkthrough The walkthrough contains 5 parts 00 – Required References 01 – Connect to TFS Programmatically 02 – Create a Work Item Programmatically 03 – Set the values of fields ‘System.ChangedDate’ and ‘System.CreatedDate’ to historic dates 04 – Results of our experiment Lets get started………………………………………………… 00 – Required References Microsoft.TeamFoundation.dll Microsoft.TeamFoundation.Client.dll Microsoft.TeamFoundation.Common.dll Microsoft.TeamFoundation.WorkItemTracking.Client.dll 01 – Connect to TFS Programmatically I have a in depth blog post on how to connect to TFS programmatically in case you are interested. However, the code snippet below will enable you to connect to TFS using the Team Project Picker. // Services I need access to globally private static TfsTeamProjectCollection _tfs; private static ProjectInfo _selectedTeamProject; private static WorkItemStore _wis; // Connect to TFS Using Team Project Picker public static bool ConnectToTfs() { var isSelected = false; // The user is allowed to select only one project var tfsPp = new TeamProjectPicker(TeamProjectPickerMode.SingleProject, false); tfsPp.ShowDialog(); // The TFS project collection _tfs = tfsPp.SelectedTeamProjectCollection; if (tfsPp.SelectedProjects.Any()) { // The selected Team Project _selectedTeamProject = tfsPp.SelectedProjects[0]; isSelected = true; } return isSelected; } 02 – Create a Work Item Programmatically In the below code snippet I have create a Product Backlog Item and a Task type work item and then link them together as parent and child. Note – You will have to set the ChangedDate to a historic date when you created the work item. Remember, If you try and set the ChangedDate to a value earlier than last assigned you will receive the following exception… TF26212: Team Foundation Server could not save your changes. There may be problems with the work item type definition. Try again or contact your Team Foundation Server administrator. If you notice below I have added a few seconds each time I have modified the ‘ChangedDate’ just to avoid running into the exception listed above. // Create Linked Work Items and return Ids private static List<int> CreateWorkItemsProgrammatically() { // Instantiate Work Item Store with the ByPassRules flag _wis = new WorkItemStore(_tfs, WorkItemStoreFlags.BypassRules); // List of work items to return var listOfWorkItems = new List<int>(); // Create a new Product Backlog Item var p = new WorkItem(_wis.Projects[_selectedTeamProject.Name].WorkItemTypes["Product Backlog Item"]); p.Title = "This is a new PBI"; p.Description = "Description"; p.IterationPath = string.Format("{0}\\Release 1\\Sprint 1", _selectedTeamProject.Name); p.AreaPath = _selectedTeamProject.Name; p["Effort"] = 10; // Just double checking that ByPassRules is set to true if (_wis.BypassRules) { p.Fields["System.ChangedDate"].Value = Convert.ToDateTime("2012-01-01"); } if (p.Validate().Count == 0) { p.Save(); listOfWorkItems.Add(p.Id); } else { Console.WriteLine(">> Following exception(s) encountered during work item save: "); foreach (var e in p.Validate()) { Console.WriteLine(" - '{0}' ", e); } } var t = new WorkItem(_wis.Projects[_selectedTeamProject.Name].WorkItemTypes["Task"]); t.Title = "This is a task"; t.Description = "Task Description"; t.IterationPath = string.Format("{0}\\Release 1\\Sprint 1", _selectedTeamProject.Name); t.AreaPath = _selectedTeamProject.Name; t["Remaining Work"] = 10; if (_wis.BypassRules) { t.Fields["System.ChangedDate"].Value = Convert.ToDateTime("2012-01-01"); } if (t.Validate().Count == 0) { t.Save(); listOfWorkItems.Add(t.Id); } else { Console.WriteLine(">> Following exception(s) encountered during work item save: "); foreach (var e in t.Validate()) { Console.WriteLine(" - '{0}' ", e); } } var linkTypEnd = _wis.WorkItemLinkTypes.LinkTypeEnds["Child"]; p.Links.Add(new WorkItemLink(linkTypEnd, t.Id) {ChangedDate = Convert.ToDateTime("2012-01-01").AddSeconds(20)}); if (_wis.BypassRules) { p.Fields["System.ChangedDate"].Value = Convert.ToDateTime("2012-01-01").AddSeconds(20); } if (p.Validate().Count == 0) { p.Save(); } else { Console.WriteLine(">> Following exception(s) encountered during work item save: "); foreach (var e in p.Validate()) { Console.WriteLine(" - '{0}' ", e); } } return listOfWorkItems; } 03 – Set the value of “Created Date” and Change the value of “Changed Date” to Historic Dates The CreatedDate can only be changed after a work item has been created. If you try and set the CreatedDate to a historic date at the time of creation of a work item, it will not work. // Lets do a work item effort burn down simulation by updating the ChangedDate & CreatedDate to historic Values private static void WorkItemChangeSimulation(IEnumerable<int> listOfWorkItems) { foreach (var id in listOfWorkItems) { var wi = _wis.GetWorkItem(id); switch (wi.Type.Name) { case "ProductBacklogItem": if (wi.State.ToLower() == "new") wi.State = "Approved"; // Advance the changed date by few seconds wi.Fields["System.ChangedDate"].Value = Convert.ToDateTime(wi.Fields["System.ChangedDate"].Value).AddSeconds(10); // Set the CreatedDate to Changed Date wi.Fields["System.CreatedDate"].Value = Convert.ToDateTime(wi.Fields["System.ChangedDate"].Value).AddSeconds(10); wi.Save(); break; case "Task": // Advance the changed date by few seconds wi.Fields["System.ChangedDate"].Value = Convert.ToDateTime(wi.Fields["System.ChangedDate"].Value).AddSeconds(10); // Set the CreatedDate to Changed date wi.Fields["System.CreatedDate"].Value = Convert.ToDateTime(wi.Fields["System.ChangedDate"].Value).AddSeconds(10); wi.Save(); break; } } // A mock sprint start date var sprintStart = DateTime.Today.AddDays(-5); // A mock sprint end date var sprintEnd = DateTime.Today.AddDays(5); // What is the total Sprint duration var totalSprintDuration = (sprintEnd - sprintStart).Days; // How much of the sprint have we already covered var noOfDaysIntoSprint = (DateTime.Today - sprintStart).Days; // Get the effort assigned to our tasks var totalEffortRemaining = QueryTaskTotalEfforRemaining(listOfWorkItems); // Defining how much effort to burn every day decimal dailyBurnRate = totalEffortRemaining / totalSprintDuration < 1 ? 1 : totalEffortRemaining / totalSprintDuration; // we have just created one task var totalNoOfTasks = 1; var simulation = sprintStart; var currentDate = DateTime.Today.Date; // Carry on till effort has been burned down from sprint start to today while (simulation.Date != currentDate.Date) { var dailyBurnRate1 = dailyBurnRate; // A fixed amount needs to be burned down each day while (dailyBurnRate1 > 0) { // burn down bit by bit from all unfinished task type work items foreach (var id in listOfWorkItems) { var wi = _wis.GetWorkItem(id); var isDirty = false; // Set the status to in progress if (wi.State.ToLower() == "to do") { wi.State = "In Progress"; isDirty = true; } // Ensure that there is enough effort remaining in tasks to burn down the daily burn rate if (QueryTaskTotalEfforRemaining(listOfWorkItems) > dailyBurnRate1) { // If there is less than 1 unit of effort left in the task, burn it all if (Convert.ToDecimal(wi["Remaining Work"]) <= 1) { wi["Remaining Work"] = 0; dailyBurnRate1 = dailyBurnRate1 - Convert.ToDecimal(wi["Remaining Work"]); isDirty = true; } else { // How much to burn from each task? var toBurn = (dailyBurnRate / totalNoOfTasks) < 1 ? 1 : (dailyBurnRate / totalNoOfTasks); // Check that the task has enough effort to allow burnForTask effort if (Convert.ToDecimal(wi["Remaining Work"]) >= toBurn) { wi["Remaining Work"] = Convert.ToDecimal(wi["Remaining Work"]) - toBurn; dailyBurnRate1 = dailyBurnRate1 - toBurn; isDirty = true; } else { wi["Remaining Work"] = 0; dailyBurnRate1 = dailyBurnRate1 - Convert.ToDecimal(wi["Remaining Work"]); isDirty = true; } } } else { dailyBurnRate1 = 0; } if (isDirty) { if (Convert.ToDateTime(wi.Fields["System.ChangedDate"].Value).Date == simulation.Date) { wi.Fields["System.ChangedDate"].Value = Convert.ToDateTime(wi.Fields["System.ChangedDate"].Value).AddSeconds(20); } else { wi.Fields["System.ChangedDate"].Value = simulation.AddSeconds(20); } wi.Save(); } } } // Increase date by 1 to perform daily burn down by day simulation = Convert.ToDateTime(simulation).AddDays(1); } } // Get the Total effort remaining in the current sprint private static decimal QueryTaskTotalEfforRemaining(List<int> listOfWorkItems) { var unfinishedWorkInCurrentSprint = _wis.GetQueryDefinition( new Guid(QueryAndGuid.FirstOrDefault(c => c.Key == "Unfinished Work").Value)); var parameters = new Dictionary<string, object> { { "project", _selectedTeamProject.Name } }; var q = new Query(_wis, unfinishedWorkInCurrentSprint.QueryText, parameters); var results = q.RunLinkQuery(); var wis = new List<WorkItem>(); foreach (var result in results) { var _wi = _wis.GetWorkItem(result.TargetId); if (_wi.Type.Name == "Task" && listOfWorkItems.Contains(_wi.Id)) wis.Add(_wi); } return wis.Sum(r => Convert.ToDecimal(r["Remaining Work"])); }   04 – The Results If you are still reading, the results are beautiful! Image 1 – Create work item with Changed Date pre-set to historic date Image 2 – Set the CreatedDate to historic date (Same as the ChangedDate) Image 3 – Simulate of effort burn down on a task via the TFS API   Image 4 – The history of changes on the Task. So, essentially this task has burned 1 hour per day Sprint Burn Down Chart – What’s not possible? The Sprint burn down chart is calculated from the System.AuthorizedDate and not the System.ChangedDate/System.CreatedDate. So, though you can change the System.ChangedDate and System.CreatedDate to historic dates you will not be able to synthesize the sprint burn down chart. Image 1 – By changing the Created Date and Changed Date to ‘18/Oct/2012’ you would have expected the burn down to have been impacted, but it won’t be, because the sprint burn down chart uses the value of field ‘System.AuthorizedDate’ to calculate the unfinished work points. The AsOf queries that are used to calculate the unfinished work points use the value of the field ‘System.AuthorizedDate’. Image 2 – Using the above code I burned down 1 hour effort per day over 5 days from the task work item, I would have expected the sprint burn down to show a constant burn down, instead the burn down shows the effort exhausted on the 24th itself. Simply because the burn down is calculated using the ‘System.AuthorizedDate’. Now you would ask… “Can I change the value of the field System.AuthorizedDate to a historic date” Unfortunately that’s not possible! You will run into the exception ValidationException –  “TF26194: The value for field ‘Authorized Date’ cannot be changed.” Conclusion - You need to be a member of the Project Collection Service account group in order to set the fields ‘System.ChangedDate’ and ‘System.CreatedDate’ to historic dates - You need to instantiate the WorkItemStore using the flag ByPassValidation - The System.ChangedDate needs to be set to a historic date at the time of work item creation. You cannot reset the ChangedDate to a date earlier than the existing ChangedDate and you cannot reset the ChangedDate to a date greater than the current date time. - The System.CreatedDate can only be reset after a work item has been created. You cannot set the CreatedDate at the time of work item creation. The CreatedDate cannot be greater than the current date. You can however reset the CreatedDate to a date earlier than the existing value. - You will not be able to synthesize the Sprint burn down chart by changing the value of System.ChangedDate and System.CreatedDate to historic dates, since the burn down chart uses AsOf queries to calculate the unfinished work points which internally uses the System.AuthorizedDate and NOT the System.ChangedDate & System.CreatedDate - System.AuthorizedDate cannot be set to a historic date using the TFS API Read other posts on using the TFS API here… Enjoy!

    Read the article

  • Can we manage incoming call number landing on asterisk?

    - by user194469
    I am using Asterisk 1.4.2 in two different machine. I have configured some extensions in asterisk. When any caller, dial my extension number with local number then if I see asterisk console (asterisk -r) then incoming number is starting with 0, but if caller dial same extension number using STD number then in asterisk console (asterisk -r), incoming number is staring with 0091 (here 91 is country code). Could I change this setting or is there any standard for asterisk for local, STD or ISD number?

    Read the article

  • How to Change Sharepoint Port

    - by Jack Levin
    I have a Sharepoint web application that I want to change the port it is running on. I am not sure how to do that as It seems that it is not enough to just go to the IIS console and change the web application port. I guess I need to do certain changes in the sharepoint Central administration console as well.

    Read the article

  • Installing Windows 2003 over remote DRAC 4

    - by Delli
    I'm trying to install windows 2003 over a DRAC 4 console session by using a ISO file. But it keeps freezing during the GUI installation then when login back Windows Setup says some files not found and setup won't continue. What's the best approach to install Windows 2003 over a DRAC 4 console session?

    Read the article

  • What's the best way to move c:\users to d:\users under vista/W7

    - by Scott
    I just installed Windows 7 RC1 and want to move c:\users to d:\users. What's the best way to do this? Due to the fact that Windows 7 creates a reserved partition that is mounted as C: in the recovery console, I had to use the following commands robocopy /mir /xj D:\Users E:\Users mklink D:\Users D:\Users /j Both D's in the mklink command are correct. When the system reboots, the drive that was D in the recovery console becomes the C drive.

    Read the article

  • How do I get the line of a javascript error in a Chrome Web Developer stack trace?

    - by David Faux
    Using Chrome Web Developer, I am analyzing a complex web page linking many javascript files. Web Developer console notes that there is a bug in the javascript. I click on the bug notice in the console, which leads me to a line in a javascript file that I have no control over and did not code. However, I want to trace this error to a line of javascript that I did write in a different file. How do I do that?

    Read the article

  • Remote administer Network Policy Server

    - by Jason Stangroome
    In our domain I have a Windows Server 2008 R2 machine "GWY" with the Network Policy and Access Services role installed. From this machine I can open the Network Policy Server management console to administer this role. However, I have another Server 2008 R2 machine "WKS" in the domain where we have all the management consoles installed so we can manage all the servers from one location. I cannot find how to access the Network Policy Server console on this machine though.

    Read the article

  • Where can I find WebSphere configuration files?

    - by Nicholas Key
    Hi there, I would like to know where are the WebSphere configuration details saved? Specifically, configuration details that are shown in the Administrative Console (from the web) or from the console using wsadmin. Some of the examples would be: Java and Process Management: Class loader, Process definition, Process execution Container Settings: Session management, SIP Container Settings, Web Container Settings, Portlet Container Settings Are there XML files that persist these configuration details? Nicholas

    Read the article

  • Convert to Managed BitLocker

    - by Doug
    I've been setting up an encryption policy using MBAM; after some trial-and-error, I finally got it working! Adding new laptops is a breeze! However... I have several laptops that were encrypten using BitLocker (and they're reporting to the MBAM Console), but I can't manage the TPM password since they're not "owned" by the server. Anybody know of a way to get these few laptops integrated into my MBAM console?

    Read the article

< Previous Page | 71 72 73 74 75 76 77 78 79 80 81 82  | Next Page >