  • How to check if PAE is enabled? (Windows 7 32 bits)

    - by Altar
    How to tell for sure if PAE (Physical Address Extensions) is enabled or not? There is a SPECIFIC command I can use? I can read a registry value or something? (Windows 7 32 bits) I have found this on Internet but it doesn't answer my question: If your server has hot-add memory ability (ability to add more memory without shutting down the server !!) or data execution prevention (DEP) is enabled then PAE will be enabled automatically !! It only reformulate the question as "does my Qosmio x505 laptop support hot-add memory?"

    Read the article

  • How to change the amount of RAM displayed in System Properties

    - by Nicu Zecheru
    I have this product that requires at least 1 GB Physical Memory in order to be installed. On my XP Pro machine I have 1 GB of RAM but in System Properties only 0.99 GB of RAM is displayed. The problem is that the product installer checks the memory displayed in System Properties (just a guess, not sure) and cannot continue the setup because it sees only 0.99 GB. Is there any way to change the displayed memory in the System Properties? Or how can I trick the installer to skip the memory check? Thanks.

    Read the article

  • Why is my USB-to-VGA'd monitor working, but not showing in Display Settings?

    - by Strilanc
    I have a USB-to-VGA adapter, which I use to connect a second monitor to my laptop (totaling 3 screens). It worked alright with Vista. I upgraded to Windows 7, and now it no longer works properly (I downloaded the latest drivers just to get it to work on 7). The extra monitor is detected and used to extend the desktop (I can move things onto it, etc), but is not shown within the Control Panel. This is annoying because now I can't changes its resolution, set its logical position to match its physical position, etc. Can I do anything, besides waiting for better drivers? I'm mainly concerned with moving its logical position. (I'd also like to understand how Windows can use a monitor it can't detect. Weird.)

    Read the article

  • organizing images by resolution with batch files

    - by Anthony
    Doing some digging I'm trying to figure out a command line solution for organizing very large archives of images based on their resolution into folders, 1920x1080, 1600x1200, 1600x900, etc. I've come across a few post on Superuser mentioning something called ImageMagick, is that the best method to the madness I'm trying to accomplish? I've never used any command line functions/applets/tools other then those that come from Microsoft. I'm rather new to command line usage but ive been enjoying the hell out of it using Powershell, xcopy and robocopy. I am slowly trying to push myself further into the Linux world with Ubuntu running on one of my physical machines as well as a virtual machine so that's an option as well.

    Read the article

  • Migrating an Active Directory domain controller to AWS

    - by Xavier Hutchinson
    I am required to migrate a Active Directory server into AWS with a couple other servers (SQL and IIS) to create a dev and test environment for our network / development. My plan at this time is to simply rebuild the Active Directory server in AWS from scratch - which is quite time consuming indeed! I was wondering if anyone had a recommendation as to a better and more efficient approach of migrating a copy of a physical Active Directory server to the cloud? The server is Windows Server 2012. Thank you!

    Read the article

  • How do you manage large web farms?

    - by Andrew Katz
    I have a quickly growing web farm running IIS 7 (30+ servers). All servers are identical copies of each other and all servers are physical. We update the software about once a month, and in the current process, we follow the following steps: Disable server from pool on F5 load balancer. Disable HTTP Keep-alives in IIS so connections drop quickly. Change default directory of website to new folder containing new binaries. Test server Enable HTTP Keep-alives. Enable server in F5 pool. Move to server 2 Microsoft used to have Application Center which was abandoned a while ago. They have made a second attempt with the Web Farm Framework, but this adds as much QA time testing the release package as it saves in the deployment. Has anyone seen a commercial off the shelf application that is tailored for managing and deploying to large web farms? Thanks!

    Read the article

  • Only One GPU Detected in the Nvidia Quadro NVS 450

    - by Kyle Brandt
    I just built myself an new workstation and now only 2 of 3 monitors are working. I built the nvidia driver by downloading it and installing with ./Nvidia... Before when I ran nvidia-settings I saw two GPUs listed but now I only see one. Xorg Config (Not sure how I ended up with 3 devices in there): # nvidia-settings: X configuration file generated by nvidia-settings # nvidia-settings: version 256.35 (buildmeister@builder101) Wed Jun 16 19:25:39 PDT 2010 Section "ServerLayout" # Removed Option "Xinerama" "1" Identifier "Layout0" Screen 0 "Screen0" 0 0 Screen 1 "Screen1" RightOf "Screen0" InputDevice "Keyboard0" "CoreKeyboard" InputDevice "Mouse0" "CorePointer" Option "Xinerama" "0" EndSection Section "Files" EndSection Section "InputDevice" # generated from default Identifier "Mouse0" Driver "mouse" Option "Protocol" "auto" Option "Device" "/dev/psaux" Option "Emulate3Buttons" "no" Option "ZAxisMapping" "4 5" EndSection Section "InputDevice" # generated from default Identifier "Keyboard0" Driver "kbd" EndSection Section "Monitor" # HorizSync source: edid, VertRefresh source: edid Identifier "Monitor0" VendorName "Unknown" ModelName "DELL E207WFP" HorizSync 30.0 - 83.0 VertRefresh 56.0 - 75.0 Option "DPMS" EndSection Section "Monitor" # HorizSync source: edid, VertRefresh source: edid Identifier "Monitor1" VendorName "Unknown" ModelName "DELL E207WFP" HorizSync 30.0 - 83.0 VertRefresh 56.0 - 75.0 Option "DPMS" EndSection Section "Monitor" # HorizSync source: edid, VertRefresh source: edid Identifier "Monitor2" VendorName "Unknown" ModelName "DELL E207WFP" HorizSync 30.0 - 83.0 VertRefresh 56.0 - 75.0 Option "DPMS" EndSection Section "Device" Identifier "Device0" Driver "nvidia" VendorName "NVIDIA Corporation" BoardName "Quadro NVS 450" BusID "PCI:6:0:0" EndSection Section "Device" Identifier "Device1" Driver "nvidia" VendorName "NVIDIA Corporation" BoardName "Quadro NVS 450" BusID "PCI:5:0:0" EndSection Section "Device" Identifier "Device2" Driver "nvidia" VendorName "NVIDIA Corporation" BoardName "Quadro NVS 450" BusID "PCI:3:0:0" EndSection Section "Screen" # Removed Option "TwinView" "0" # Removed Option "metamodes" "DFP-0: nvidia-auto-select +0+0" # Removed Option "metamodes" "DFP-0: nvidia-auto-select +0+275, DFP-3: nvidia-auto-select +1680+0" Identifier "Screen0" Device "Device0" Monitor "Monitor0" DefaultDepth 24 Option "TwinView" "1" Option "TwinViewXineramaInfoOrder" "DFP-3" Option "metamodes" "DFP-0: nvidia-auto-select +0+0, DFP-3: nvidia-auto-select +1680+0" SubSection "Display" Depth 24 EndSubSection EndSection Section "Screen" # Removed Option "metamodes" "DFP-3: nvidia-auto-select +0+0" Identifier "Screen1" Device "Device1" Monitor "Monitor1" DefaultDepth 24 Option "TwinView" "0" Option "metamodes" "nvidia-auto-select +0+0" SubSection "Display" Depth 24 EndSubSection EndSection Section "Screen" Identifier "Screen2" Device "Device2" Monitor "Monitor2" DefaultDepth 24 Option "TwinView" "0" Option "metamodes" "nvidia-auto-select +0+0" SubSection "Display" Depth 24 EndSubSection EndSection lscpi: 00:00.0 Host bridge: Intel Corporation 5520/5500/X58 I/O Hub to ESI Port (rev 13) 00:01.0 PCI bridge: Intel Corporation 5520/5500/X58 I/O Hub PCI Express Root Port 1 (rev 13) 00:02.0 PCI bridge: Intel Corporation 5520/5500/X58 I/O Hub PCI Express Root Port 2 (rev 13) 00:03.0 PCI bridge: Intel Corporation 5520/5500/X58 I/O Hub PCI Express Root Port 3 (rev 13) 00:10.0 PIC: Intel Corporation 5520/5500/X58 Physical and Link Layer Registers Port 0 (rev 13) 00:10.1 PIC: Intel Corporation 5520/5500/X58 Routing and Protocol Layer Registers Port 0 (rev 13) 00:11.0 PIC: Intel Corporation 5520/5500 Physical and Link Layer Registers Port 1 (rev 13) 00:11.1 PIC: Intel Corporation 5520/5500 Routing & Protocol Layer Register Port 1 (rev 13) 00:13.0 PIC: Intel Corporation 5520/5500/X58 I/O Hub I/OxAPIC Interrupt Controller (rev 13) 00:14.0 PIC: Intel Corporation 5520/5500/X58 I/O Hub System Management Registers (rev 13) 00:14.1 PIC: Intel Corporation 5520/5500/X58 I/O Hub GPIO and Scratch Pad Registers (rev 13) 00:14.2 PIC: Intel Corporation 5520/5500/X58 I/O Hub Control Status and RAS Registers (rev 13) 00:15.0 PIC: Intel Corporation 5520/5500/X58 Trusted Execution Technology Registers (rev 13) 00:1a.0 USB Controller: Intel Corporation 82801JI (ICH10 Family) USB UHCI Controller #4 00:1a.1 USB Controller: Intel Corporation 82801JI (ICH10 Family) USB UHCI Controller #5 00:1a.2 USB Controller: Intel Corporation 82801JI (ICH10 Family) USB UHCI Controller #6 00:1a.7 USB Controller: Intel Corporation 82801JI (ICH10 Family) USB2 EHCI Controller #2 00:1b.0 Audio device: Intel Corporation 82801JI (ICH10 Family) HD Audio Controller 00:1c.0 PCI bridge: Intel Corporation 82801JI (ICH10 Family) PCI Express Root Port 1 00:1c.1 PCI bridge: Intel Corporation 82801JI (ICH10 Family) PCI Express Port 2 00:1c.3 PCI bridge: Intel Corporation 82801JI (ICH10 Family) PCI Express Root Port 4 00:1c.4 PCI bridge: Intel Corporation 82801JI (ICH10 Family) PCI Express Root Port 5 00:1d.0 USB Controller: Intel Corporation 82801JI (ICH10 Family) USB UHCI Controller #1 00:1d.1 USB Controller: Intel Corporation 82801JI (ICH10 Family) USB UHCI Controller #2 00:1d.2 USB Controller: Intel Corporation 82801JI (ICH10 Family) USB UHCI Controller #3 00:1d.7 USB Controller: Intel Corporation 82801JI (ICH10 Family) USB2 EHCI Controller #1 00:1e.0 PCI bridge: Intel Corporation 82801 PCI Bridge (rev 90) 00:1f.0 ISA bridge: Intel Corporation 82801JIR (ICH10R) LPC Interface Controller 00:1f.2 IDE interface: Intel Corporation 82801JI (ICH10 Family) 4 port SATA IDE Controller #1 00:1f.3 SMBus: Intel Corporation 82801JI (ICH10 Family) SMBus Controller 00:1f.5 IDE interface: Intel Corporation 82801JI (ICH10 Family) 2 port SATA IDE Controller #2 01:00.0 IDE interface: Device 1b4b:91a3 (rev 11) 02:00.0 USB Controller: NEC Corporation Device 0194 (rev 03) 03:00.0 PCI bridge: nVidia Corporation PCI express bridge for Quadro Plex S4 / Tesla S870 / Tesla S1070 (rev a3) 04:00.0 PCI bridge: nVidia Corporation PCI express bridge for Quadro Plex S4 / Tesla S870 / Tesla S1070 (rev a3) 04:02.0 PCI bridge: nVidia Corporation PCI express bridge for Quadro Plex S4 / Tesla S870 / Tesla S1070 (rev a3) 05:00.0 3D controller: nVidia Corporation G98 [Quadro NVS 450] (rev a1) 06:00.0 VGA compatible controller: nVidia Corporation G98 [Quadro NVS 450] (rev a1) 08:00.0 SATA controller: JMicron Technology Corp. JMB362/JMB363 Serial ATA Controller (rev 02) 08:00.1 IDE interface: JMicron Technology Corp. JMB362/JMB363 Serial ATA Controller (rev 02) 09:00.0 SATA controller: JMicron Technology Corp. JMB362/JMB363 Serial ATA Controller (rev 03) 09:00.1 IDE interface: JMicron Technology Corp. JMB362/JMB363 Serial ATA Controller (rev 03) 0a:00.0 Ethernet controller: Realtek Semiconductor Co., Ltd. RTL8111/8168B PCI Express Gigabit Ethernet controller (rev 06) 0b:06.0 FireWire (IEEE 1394): Texas Instruments TSB43AB23 IEEE-1394a-2000 Controller (PHY/Link)

    Read the article

  • Simple NAT router for ESX

    - by Evan M.
    Hi Guys, I'm looking for a simple virtual appliance that I can deploy to my ESX environment to use as a virtual NAT router / firewall to create an isolated network that I can easily give internet access too. Basic setup: ESX Host, has 2 vswitches configured: 1 is connected to the physical LAN, the other is isolated. I need an appliance that I can add 2 vNICs to, and attach one to the isolated vSwitch, the other to the LAN, to give the isolated network outbound access (so it can reach the internet). Anyone have an appliance that I can setup quickly to do so? Thanks.

    Read the article

  • keepalived questions (requirements, abilities, limitations)

    - by Poni
    1) What are keepalived's (physical/network) requirements? Does the two (or more) keepalived' nodes need to be connected to the same switch? (something related to broadcasting maybe). 2) Can keepalived nodes run on different networks, "internet" networks? 3) Is keepalived depend on the router? (as far as I understand, the virtual IP should point to the real router/switch that connects both nodes). 4) Is keepalived "service-independent"? - What is keepalived's involvement domain? IPs only? Or is it service/protocol oriented? - Does it deal ONLY with IP, or is it designed for HTTP for example? - In other words, can I use it for custom (network-based) app? 5) Have more than one failover server? If the answer for question #4 is "yes", i.e it depends on the service type, then is there any general alternative? Preferably easy to install/configure :)

    Read the article

  • Integration of Tomcat 7 with IIS 7

    - by priya
    After following all the steps related to integration of tomcat7 and IIS7 i am getting below error.Any idea what might be the cause?First time when I did all the steps as mentioned in tutorial my site was coming up then suddenly it stop coming up.Again i removed my site from IIS and followed the steps but then every time below error is coming:- HTTP Error 500.0 - Internal Server Error The page cannot be displayed because an internal server error has occurred. Detailed Error Information Module IsapiFilterModule Notification AuthenticateRequest Handler StaticFile Error Code 0x80070001 Physical Path D:\New\IISROOT Logon Method Anonymous Logon User Anonymous Failed Request Tracing Log Directory D:\New\Tomcat\logs I have checked the logs but trace log is not created as well as isapi_redirect.logs

    Read the article

  • How to get the basic mail command in ubuntu 10 to work

    - by Maureen Adamson
    I am a college lecturer to whom the task of supporting the students' Linux Server has fallen. My students just need to use the mail command to communicate with me and each other. I thought mail would be there by default but it wasn't. I have tried all the advice I found on the Internet and tried to install mailutils, sendmail, mailx, exim4 and postfix. There were more but I can't remember them all now. After installing (if it works - some of them don't), when I try to send a message they all give me: /usr/sbin/sendmail: file or directory not found. I don't need anything fancy - we don't need to access remote email, just locally on our server. Incidentally the same problems are occurring on the physical server and my test virtual machine, installed at different times but both Ubuntu 10. Can anyone help me?

    Read the article

  • How to stop ethernet interface in bridge configuration from obtaining IP address via DHCP

    - by user71061
    Hi! I'm trying to configure openvpn in bridging configuration. First step of doing this requires creating bridge interface (br0), bridging together physical ethernet interface (eth0) and logical tap0 interface. This can be done with simple script but I want to use less popular approach, configuring bridge interface entirely via /etc/network/interfaces file (on Debian linux). So I have removed all eth0 definitions form /etc/network/interfaces and replaced if with following br0 definition: auto br0 iface br0 inet static pre-up openvpn --mktun --dev tap0 address 10.0.0.1 netmask 255.255.255.0 bridge_ports eth0 tap0 post-down openvpn --rmtun --dev tap0 This works as I expected, but there is only one problem: interface eth0 is part of bridge interface br0 AND it also receive it's own IP address from my DHCP server (located on same LAN where eth0 is connected). My questions is: how to stop eth0 interface from obtaining it's own IP address? (It should only be part of br0 bridge).

    Read the article

  • Securing a local server physically

    - by Daniele
    We are an online business. We have a very powerful server with hard disk mirroring in our office that we are using for a variety of internal business-critical functions. We want to keep that machine in our office but we want to make sure it is as secure as possible (within reason). Obviously we are already backing it up everyday off-site. My question is more about not-too-expensive physical measures to protect the machine against thieves and disasters such as fire. What would you suggest?

    Read the article

  • perfmon reporting higher IOPs than possible?

    - by BlueToast
    We created a monitoring report for IOPs on performance counters using Disk reads/sec and Disk writes/sec on four servers (physical boxes, no virtualization) that have 4x 15k 146GB SAS drives in RAID10 per server, set to check and record data every 1 second, and logged for 24 hours before stopping reports. These are the results we got: Server1 Maximum disk reads/sec: 4249.437 Maximum disk writes/sec: 4178.946 Server2 Maximum disk reads/sec: 2550.140 Maximum disk writes/sec: 5177.821 Server3 Maximum disk reads/sec: 1903.300 Maximum disk writes/sec: 5299.036 Server4 Maximum disk reads/sec: 8453.572 Maximum disk writes/sec: 11584.653 The average disk reads and writes per second were generally low. I.e. for one particular server it was like average 33 writes/sec, but when monitoring in real-time it would often spike up to several hundreds and also sometimes into the thousands. Could someone explain to me why these numbers are significantly higher than theoretical calculations assuming each drive can do 180 IOPs? Additional details (RAID card): HP Smart Array P410i, Total cache size of 1GB, Write cache is disabled, Array accelerator cache ratio is 25% read and 75% write

    Read the article

  • Can a power failure or forceful shutdown damage hardware?

    - by Vilx-
    Can computer hardware suffer damage from forceful shutdowns (holding the power button for five (5) seconds) or power failures? I believe that normal PC hardware does not suffer from this - after all, it's not much different than what they experience under a standard shutdown. But elsewhere I've read tht another person thought that it could do physical harm to the hard drive and possibly other components as well. He also said that the journaling features of filesystems are useless in face of power failures and were intended to help mitigate damage from system crashes. I think this is nonsense, but then again I lack the experience and knowledge to say it with certainty.

    Read the article

  • IIS permissions issue pointing docroot to Samba share

    - by lalalalalalalambda
    I have an IIS project which is stored on a Samba shared, network mounted with the following line: X: \\my-samba-server\dev /user:freddie Connectivity is fine, can read/write files from X:. In IIS, I'm trying to set it as the Physical path via \\my-samba-server\dev\folder\to\my\files, which results in the following 500.19 error: Config Error | Cannot read configuration file due to insufficient permissions It is by default trying to use the Pass-through authentication. If I try to set this to connect as the specific user freddie, I receive: The specified user does not exist What is the correct way to connect to a path which has been setup as described above? *Samba man pages indicate version 3.6 is on the Debian host

    Read the article

  • Best practice on Linux servers and CPU/power throttling?

    - by Valentin
    I am running a couple of Debian 6 (2.6.32) and 7 (3.2) Linux servers and all of them have energy saving settings enabled in their BIOS. Furthermore Linux shows that the CPUs are throttled if the servers are idling. I wonder if this could cause any harm - could there be e.g. performance impacts because Linux would not be able to handle throttling correctly? Is there a best practice for Linux servers and power/CPU throttling? Do you guys switch your energy profiles to "performance" or do you leave both the BIOS and the OS with their default settings? The reason I am asking is that I encountered several performance issues on physical Dell servers although all values (CPU/load, memory, I/O, network etc.) seemed to be normal. After changing the BIOS power settings to "performance" in those specific cases, I was able to get rid of the performance issues.

    Read the article

  • Intel SASWT4I SAS/SATA Controller Question

    - by Joe Hopfgartner
    Hey there! I want to assemble a cheap storage sytem based on the Norco RPC-4020 Case. When searching for controllers I found this one: Intel® RAID Controller SASWT4I This is a quote form the Spec Sheet: Scalability. Supports up to 122 physical devices in SAS mode which is ideal for employing JBODs (Just a Bunch Of Disks) or up to 14 devices in RAID 0, 1, 1E/10E mode through direct connect device attachment or through expander backplane support. Does that mean I can attatch 14 SATA drives directly to the controller using SFF-8087 - 4x SATA breakout cables? That would be nice because then I can choose a mainboard that has 6 Onboard SATA and i can connect all 20 bays while only spending 155$ on the controller and like another 100$ on cables. Would that work? And why is it 14 and not 16 when there are 4 Ports? I am really confused about all the breakout/fanout/(edge-)expanding/multiplying/channel stuff...

    Read the article

  • Adaptec 2020SA RAID controller Set up in RAID5, one drive went down, can I still get data?

    - by SJaguar13
    I have 6 1tb drives in a RAID5. 1 drive went down. On the RAID was 2 virtual machines that I really need back up and running. The spare drive I have to put in the server is a 1.5tb drive, which exceeds the physical per drive limit of the 2020SA. The drive is found in the disk utility, but it is not found in the array management section. I cannot add the drive to the array to have it rebuild. I have a replacement drive along with some spares on their way from Newegg, but I am still looking at a few days of downtime. Is it possible to use the 5 working drives to get the VMs copied off and on to another server or do I just have to wait for the drives to get here?

    Read the article

  • Can we put random URL entries on DNS

    - by ring bearer
    Using microsoft DNS All/most of our local hosts ( with in ) are in following domain *.company.org So a host name will look like mymachine001.company.org Is it possible to set up wild card DNS entries of the form ? *.subd.company.com Note: The URL ends with .com, all other hosts so far ever set up in the DNS were of the format *.company.org what i am trying to achieve is the following. A user with in internal network types a url http://someprefix.subd.company.com in browser and enters. Since there is a wild card entry in DNS, the user gets routed to host mapped to *.subd.company.com in the DNS Note : at the same time, company.com has a public DNS entry and that is mapped to a physical IP in some other network (data center)

    Read the article

  • PostgreSQL RAID configuration

    - by Yoldar-Zi
    I'm stuck how best to configure disk array. We have Hp P2000 G3 disk array with 24 SAS physical disks 300Gb each. We need to configure this array got 2 copies of PostgreSQL 9.2 because two different system. As we know it's recommended to store database and transaction logs(pg_xlog) files on separate disks. So we must setup 4 logical disk: 2 for transaction logs with RAID 1 2 for database with RAID 10 Is this right scheme of distribution? Or may be it is best to just make one big RAID 10 with 4 logical disks?

    Read the article

  • Design Question

    - by dturner71
    Can I have two independent Connection servers attached to the same vCenter server? Here's my scenario. I'm setting up View 4 to provide desktops to two seperate Windows domains that are on different IP subnets seperated by a firewall. One cluster of physical servers, one vCenter server, linked clones. As I understand it View Connection server has to be a member of a Windows domain in order for quickprep to work. So the way to provide desktops to both Windows domains is to have a Connection server in each one right? Then open ports in the firewall so the Connection server from the other subnet can communicate with vCenter. Any reason why this won't work? Or is there a better way to accomplish it?

    Read the article

  • What is causing a vm to exhibit packet loss?

    - by Joe Philllips
    We have a pretty nice piece of hardware set up to run multiple virtual machines in vmware and one of the vm's is an instance of Windows Server 2003 running SQL Server 2005. For some reason we occasionally see 10-20 seconds of straight packet loss to this machine from remote machines (my workstation) as well as other vm's on the same physical hardware. I am using PingPlotter to keep a close eye on the packet loss. So far we've turned off flow control on the NIC but we are already running out of other things to try. What might be causing this and how can I identify the problem? Note: We also have another server with a very similar configuration with the same type of problem to a lesser extent (because its not used as heavily?)

    Read the article

  • how to copy sql server database on same server

    - by Sam
    I've got a SQL Server 2008 and want to make a copy of a database so I've got a 2nd Version of the database for testing on the same server. The database copy wizard is not able to copy the database, it always sends funny error Messages about missing objects (using SMO copy). When I try to make a backup and restore it under a different database name it still keeps the file names of the original database and overrides this (crashing the original database). So how do I copy a SQL database? Shutdown SQL Server, copy the physical files and attach them? Maybe a command line tool for database copy? Shouldn't there be an easy way to make a copy?

    Read the article

  • Various problems with software raid1 array built with Samsung 840 Pro SSDs

    - by Andy B
    I am bringing to ServerFault a problem that is tormenting me for 6+ months. I have a CentOS 6 (64bit) server with an md software raid-1 array with 2 x Samsung 840 Pro SSDs (512GB). Problems: Serious write speed problems: root [~]# time dd if=arch.tar.gz of=test4 bs=2M oflag=sync 146+1 records in 146+1 records out 307191761 bytes (307 MB) copied, 23.6788 s, 13.0 MB/s real 0m23.680s user 0m0.000s sys 0m0.932s When doing the above (or any other larger copy) the load spikes to unbelievable values (even over 100) going up from ~ 1. When doing the above I've also noticed very weird iostat results: Device: rrqm/s wrqm/s r/s w/s rsec/s wsec/s avgrq-sz avgqu-sz await svctm %util sda 0.00 1589.50 0.00 54.00 0.00 13148.00 243.48 0.60 11.17 0.46 2.50 sdb 0.00 1627.50 0.00 16.50 0.00 9524.00 577.21 144.25 1439.33 60.61 100.00 md1 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 md2 0.00 0.00 0.00 1602.00 0.00 12816.00 8.00 0.00 0.00 0.00 0.00 md0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 And it keeps it this way until it actually writes the file to the device (out from swap/cache/memory). The problem is that the second SSD in the array has svctm and await roughly 100 times larger than the second. For some reason the wear is different between the 2 members of the array root [~]# smartctl --attributes /dev/sda | grep -i wear 177 Wear_Leveling_Count 0x0013 094% 094 000 Pre-fail Always - 180 root [~]# smartctl --attributes /dev/sdb | grep -i wear 177 Wear_Leveling_Count 0x0013 070% 070 000 Pre-fail Always - 1005 The first SSD has a wear of 6% while the second SSD has a wear of 30%!! It's like the second SSD in the array works at least 5 times as hard as the first one as proven by the first iteration of iostat (the averages since reboot): Device: rrqm/s wrqm/s r/s w/s rsec/s wsec/s avgrq-sz avgqu-sz await svctm %util sda 10.44 51.06 790.39 125.41 8803.98 1633.11 11.40 0.33 0.37 0.06 5.64 sdb 9.53 58.35 322.37 118.11 4835.59 1633.11 14.69 0.33 0.76 0.29 12.97 md1 0.00 0.00 1.88 1.33 15.07 10.68 8.00 0.00 0.00 0.00 0.00 md2 0.00 0.00 1109.02 173.12 10881.59 1620.39 9.75 0.00 0.00 0.00 0.00 md0 0.00 0.00 0.41 0.01 3.10 0.02 7.42 0.00 0.00 0.00 0.00 What I've tried: I've updated the firmware to DXM05B0Q (following reports of dramatic improvements for 840Ps after this update). I have looked for "hard resetting link" in dmesg to check for cable/backplane issues but nothing. I have checked the alignment and I believe they are aligned correctly (1MB boundary, listing below) I have checked /proc/mdstat and the array is Optimal (second listing below). root [~]# fdisk -ul /dev/sda Disk /dev/sda: 512.1 GB, 512110190592 bytes 255 heads, 63 sectors/track, 62260 cylinders, total 1000215216 sectors Units = sectors of 1 * 512 = 512 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x00026d59 Device Boot Start End Blocks Id System /dev/sda1 2048 4196351 2097152 fd Linux raid autodetect Partition 1 does not end on cylinder boundary. /dev/sda2 * 4196352 4605951 204800 fd Linux raid autodetect Partition 2 does not end on cylinder boundary. /dev/sda3 4605952 814106623 404750336 fd Linux raid autodetect root [~]# fdisk -ul /dev/sdb Disk /dev/sdb: 512.1 GB, 512110190592 bytes 255 heads, 63 sectors/track, 62260 cylinders, total 1000215216 sectors Units = sectors of 1 * 512 = 512 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x0003dede Device Boot Start End Blocks Id System /dev/sdb1 2048 4196351 2097152 fd Linux raid autodetect Partition 1 does not end on cylinder boundary. /dev/sdb2 * 4196352 4605951 204800 fd Linux raid autodetect Partition 2 does not end on cylinder boundary. /dev/sdb3 4605952 814106623 404750336 fd Linux raid autodetect /proc/mdstat root # cat /proc/mdstat Personalities : [raid1] md0 : active raid1 sdb2[1] sda2[0] 204736 blocks super 1.0 [2/2] [UU] md2 : active raid1 sdb3[1] sda3[0] 404750144 blocks super 1.0 [2/2] [UU] md1 : active raid1 sdb1[1] sda1[0] 2096064 blocks super 1.1 [2/2] [UU] unused devices: Running a read test with hdparm root [~]# hdparm -t /dev/sda /dev/sda: Timing buffered disk reads: 664 MB in 3.00 seconds = 221.33 MB/sec root [~]# hdparm -t /dev/sdb /dev/sdb: Timing buffered disk reads: 288 MB in 3.01 seconds = 95.77 MB/sec But look what happens if I add --direct root [~]# hdparm --direct -t /dev/sda /dev/sda: Timing O_DIRECT disk reads: 788 MB in 3.01 seconds = 262.08 MB/sec root [~]# hdparm --direct -t /dev/sdb /dev/sdb: Timing O_DIRECT disk reads: 534 MB in 3.02 seconds = 176.90 MB/sec Both tests increase but /dev/sdb doubles while /dev/sda increases maybe 20%. I just don't know what to make of this. As suggested by Mr. Wagner I've done another read test with dd this time and it confirms the hdparm test: root [/home2]# dd if=/dev/sda of=/dev/null bs=1G count=10 10+0 records in 10+0 records out 10737418240 bytes (11 GB) copied, 38.0855 s, 282 MB/s root [/home2]# dd if=/dev/sdb of=/dev/null bs=1G count=10 10+0 records in 10+0 records out 10737418240 bytes (11 GB) copied, 115.24 s, 93.2 MB/s So sda is 3 times faster than sdb. Or maybe sdb is doing also something else besides what sda does. Is there some way to find out if sdb is doing more than what sda does? UPDATE Again, as suggested by Mr. Wagner, I have swapped the 2 SSDs. And as he thought it would happen, the problem moved from sdb to sda. So I guess I'll RMA one of the SSDs. I wonder if the cage might be problematic. What is wrong with this array? Please help!