Search Results

Search found 3463 results on 139 pages for 'physical'.

Page 75/139 | < Previous Page | 71 72 73 74 75 76 77 78 79 80 81 82  | Next Page >

  • Best practice on Linux servers and CPU/power throttling?

    - by Valentin
    I am running a couple of Debian 6 (2.6.32) and 7 (3.2) Linux servers and all of them have energy saving settings enabled in their BIOS. Furthermore Linux shows that the CPUs are throttled if the servers are idling. I wonder if this could cause any harm - could there be e.g. performance impacts because Linux would not be able to handle throttling correctly? Is there a best practice for Linux servers and power/CPU throttling? Do you guys switch your energy profiles to "performance" or do you leave both the BIOS and the OS with their default settings? The reason I am asking is that I encountered several performance issues on physical Dell servers although all values (CPU/load, memory, I/O, network etc.) seemed to be normal. After changing the BIOS power settings to "performance" in those specific cases, I was able to get rid of the performance issues.

    Read the article

  • HP DL380 G5 Predictive Drive Failure on a new drive

    - by CharlieJ
    Consolidated Error Report: Controller: Smart Array P400 in slot 3 Device: Physical Drive 1I:1:1 Message: Predictive failure. We have an HP DL380 G5 server with two 72GB 15k SAS drives configured in RAID1. A couple weeks ago, the server reported a drive failure on Drive 1. We replaced the drive with a brand new HDD -- same spares number. A few days ago, the server started reporting a predictive drive failure on the new drive, in the same bay. Is it likely the new drive is bad... or more likely we have a bay failure problem? This is a production server, so any advice would be appreciated. I have another spare drive, so I can hot swap it if this is a fluke and new drive is just bad. THANKS! CharlieJ

    Read the article

  • Gparted: Copy Greyed Out

    - by David
    I booted my system to a gparted linux live CD and I have two partitions: /dev/sda1 /dev/sda2 I want to move both of them to my new physical hard drive (called /dev/sdb). When I right click on /dev/sda1, I can choose copy and then paste it onto /dev/sdb. When I right click on /dev/sda2, copy is greyed out and there is a yellow exclamation point to the left of the disk. I know that the disk works since I can boot my computer from it. Why won't gparted let me copy /dev/sda2 to my new hard disk? Since the option is greyed out, I don't even get an error message. Thanks!

    Read the article

  • Change user login in Windows 7 (after a misprint in username)

    - by Artem Russakovskii
    I have an install of Windows 7 that I've already put a few days into. Today I realized I've made a mistake in the username and it's driving me nuts (my personal OCD). While changing the physical folder name is perhaps possible, though quite involved, I do not want to open that can of worms. What I want to do is simply change the username I give when the login prompt shows up. I thought it's possible by just renaming the user account in the User Accounts but that didn't work. Is it possible to do then? Or is the only way to create another user and spend hour migrating everything I'd already customized to that user?

    Read the article

  • What is causing a vm to exhibit packet loss?

    - by Joe Philllips
    We have a pretty nice piece of hardware set up to run multiple virtual machines in vmware and one of the vm's is an instance of Windows Server 2003 running SQL Server 2005. For some reason we occasionally see 10-20 seconds of straight packet loss to this machine from remote machines (my workstation) as well as other vm's on the same physical hardware. I am using PingPlotter to keep a close eye on the packet loss. So far we've turned off flow control on the NIC but we are already running out of other things to try. What might be causing this and how can I identify the problem? Note: We also have another server with a very similar configuration with the same type of problem to a lesser extent (because its not used as heavily?)

    Read the article

  • Which tool / technology: System management for databases and dependent services

    - by Filburt
    I'm looking for advice on how to enable our team to take down and re-start our company systems for maintainance purposes. The scenario includes several Oracle db machines several MS SQL Server machines with multiple instances windows services (IIS etc.) BizTalk EAI solution Apache and Tomcat instances lots of scheduled tasks on win2003 and win2008 machines (physical and virtual). The main focus is on capture all dependencies between said databases and services and tasks connecting to them. At the moment an enterprise class solution is not an option. We are considering developing a solution driven by PowerShell scripts but I hope for some more suggestions.

    Read the article

  • MySQL Windows vs. Linux: performance, caveats, pros and cons?

    - by gravyface
    Looking for (preferrably) some hard data or at least some experienced anecdotal responses with regards to hosting a MySQL database (roughly 5k transactions a day, 60-70% more reads than writes, < 100k of data per transaction i.e. no large binary objects like images, etc.) on Windows 2003/2008 vs. a Debian-based derivative (Ubuntu/Debian, etc.). This server will function only as a database server with a separate Web server on another physical box; this server will require remote access for management (SSH for Linux, RDP for Windows). I suspect that the Linux kernel/OS will compete less than the Windows Server for resources, but for this I can't be certain. There's also security footprint: even with Windows 2008, I'm thinking that the Linux box can be locked down more easily than the Windows Server. Anyone have any experience with both configurations?

    Read the article

  • Only One GPU Detected in the Nvidia Quadro NVS 450

    - by Kyle Brandt
    I just built myself an new workstation and now only 2 of 3 monitors are working. I built the nvidia driver by downloading it and installing with ./Nvidia... Before when I ran nvidia-settings I saw two GPUs listed but now I only see one. Xorg Config (Not sure how I ended up with 3 devices in there): # nvidia-settings: X configuration file generated by nvidia-settings # nvidia-settings: version 256.35 (buildmeister@builder101) Wed Jun 16 19:25:39 PDT 2010 Section "ServerLayout" # Removed Option "Xinerama" "1" Identifier "Layout0" Screen 0 "Screen0" 0 0 Screen 1 "Screen1" RightOf "Screen0" InputDevice "Keyboard0" "CoreKeyboard" InputDevice "Mouse0" "CorePointer" Option "Xinerama" "0" EndSection Section "Files" EndSection Section "InputDevice" # generated from default Identifier "Mouse0" Driver "mouse" Option "Protocol" "auto" Option "Device" "/dev/psaux" Option "Emulate3Buttons" "no" Option "ZAxisMapping" "4 5" EndSection Section "InputDevice" # generated from default Identifier "Keyboard0" Driver "kbd" EndSection Section "Monitor" # HorizSync source: edid, VertRefresh source: edid Identifier "Monitor0" VendorName "Unknown" ModelName "DELL E207WFP" HorizSync 30.0 - 83.0 VertRefresh 56.0 - 75.0 Option "DPMS" EndSection Section "Monitor" # HorizSync source: edid, VertRefresh source: edid Identifier "Monitor1" VendorName "Unknown" ModelName "DELL E207WFP" HorizSync 30.0 - 83.0 VertRefresh 56.0 - 75.0 Option "DPMS" EndSection Section "Monitor" # HorizSync source: edid, VertRefresh source: edid Identifier "Monitor2" VendorName "Unknown" ModelName "DELL E207WFP" HorizSync 30.0 - 83.0 VertRefresh 56.0 - 75.0 Option "DPMS" EndSection Section "Device" Identifier "Device0" Driver "nvidia" VendorName "NVIDIA Corporation" BoardName "Quadro NVS 450" BusID "PCI:6:0:0" EndSection Section "Device" Identifier "Device1" Driver "nvidia" VendorName "NVIDIA Corporation" BoardName "Quadro NVS 450" BusID "PCI:5:0:0" EndSection Section "Device" Identifier "Device2" Driver "nvidia" VendorName "NVIDIA Corporation" BoardName "Quadro NVS 450" BusID "PCI:3:0:0" EndSection Section "Screen" # Removed Option "TwinView" "0" # Removed Option "metamodes" "DFP-0: nvidia-auto-select +0+0" # Removed Option "metamodes" "DFP-0: nvidia-auto-select +0+275, DFP-3: nvidia-auto-select +1680+0" Identifier "Screen0" Device "Device0" Monitor "Monitor0" DefaultDepth 24 Option "TwinView" "1" Option "TwinViewXineramaInfoOrder" "DFP-3" Option "metamodes" "DFP-0: nvidia-auto-select +0+0, DFP-3: nvidia-auto-select +1680+0" SubSection "Display" Depth 24 EndSubSection EndSection Section "Screen" # Removed Option "metamodes" "DFP-3: nvidia-auto-select +0+0" Identifier "Screen1" Device "Device1" Monitor "Monitor1" DefaultDepth 24 Option "TwinView" "0" Option "metamodes" "nvidia-auto-select +0+0" SubSection "Display" Depth 24 EndSubSection EndSection Section "Screen" Identifier "Screen2" Device "Device2" Monitor "Monitor2" DefaultDepth 24 Option "TwinView" "0" Option "metamodes" "nvidia-auto-select +0+0" SubSection "Display" Depth 24 EndSubSection EndSection lscpi: 00:00.0 Host bridge: Intel Corporation 5520/5500/X58 I/O Hub to ESI Port (rev 13) 00:01.0 PCI bridge: Intel Corporation 5520/5500/X58 I/O Hub PCI Express Root Port 1 (rev 13) 00:02.0 PCI bridge: Intel Corporation 5520/5500/X58 I/O Hub PCI Express Root Port 2 (rev 13) 00:03.0 PCI bridge: Intel Corporation 5520/5500/X58 I/O Hub PCI Express Root Port 3 (rev 13) 00:10.0 PIC: Intel Corporation 5520/5500/X58 Physical and Link Layer Registers Port 0 (rev 13) 00:10.1 PIC: Intel Corporation 5520/5500/X58 Routing and Protocol Layer Registers Port 0 (rev 13) 00:11.0 PIC: Intel Corporation 5520/5500 Physical and Link Layer Registers Port 1 (rev 13) 00:11.1 PIC: Intel Corporation 5520/5500 Routing & Protocol Layer Register Port 1 (rev 13) 00:13.0 PIC: Intel Corporation 5520/5500/X58 I/O Hub I/OxAPIC Interrupt Controller (rev 13) 00:14.0 PIC: Intel Corporation 5520/5500/X58 I/O Hub System Management Registers (rev 13) 00:14.1 PIC: Intel Corporation 5520/5500/X58 I/O Hub GPIO and Scratch Pad Registers (rev 13) 00:14.2 PIC: Intel Corporation 5520/5500/X58 I/O Hub Control Status and RAS Registers (rev 13) 00:15.0 PIC: Intel Corporation 5520/5500/X58 Trusted Execution Technology Registers (rev 13) 00:1a.0 USB Controller: Intel Corporation 82801JI (ICH10 Family) USB UHCI Controller #4 00:1a.1 USB Controller: Intel Corporation 82801JI (ICH10 Family) USB UHCI Controller #5 00:1a.2 USB Controller: Intel Corporation 82801JI (ICH10 Family) USB UHCI Controller #6 00:1a.7 USB Controller: Intel Corporation 82801JI (ICH10 Family) USB2 EHCI Controller #2 00:1b.0 Audio device: Intel Corporation 82801JI (ICH10 Family) HD Audio Controller 00:1c.0 PCI bridge: Intel Corporation 82801JI (ICH10 Family) PCI Express Root Port 1 00:1c.1 PCI bridge: Intel Corporation 82801JI (ICH10 Family) PCI Express Port 2 00:1c.3 PCI bridge: Intel Corporation 82801JI (ICH10 Family) PCI Express Root Port 4 00:1c.4 PCI bridge: Intel Corporation 82801JI (ICH10 Family) PCI Express Root Port 5 00:1d.0 USB Controller: Intel Corporation 82801JI (ICH10 Family) USB UHCI Controller #1 00:1d.1 USB Controller: Intel Corporation 82801JI (ICH10 Family) USB UHCI Controller #2 00:1d.2 USB Controller: Intel Corporation 82801JI (ICH10 Family) USB UHCI Controller #3 00:1d.7 USB Controller: Intel Corporation 82801JI (ICH10 Family) USB2 EHCI Controller #1 00:1e.0 PCI bridge: Intel Corporation 82801 PCI Bridge (rev 90) 00:1f.0 ISA bridge: Intel Corporation 82801JIR (ICH10R) LPC Interface Controller 00:1f.2 IDE interface: Intel Corporation 82801JI (ICH10 Family) 4 port SATA IDE Controller #1 00:1f.3 SMBus: Intel Corporation 82801JI (ICH10 Family) SMBus Controller 00:1f.5 IDE interface: Intel Corporation 82801JI (ICH10 Family) 2 port SATA IDE Controller #2 01:00.0 IDE interface: Device 1b4b:91a3 (rev 11) 02:00.0 USB Controller: NEC Corporation Device 0194 (rev 03) 03:00.0 PCI bridge: nVidia Corporation PCI express bridge for Quadro Plex S4 / Tesla S870 / Tesla S1070 (rev a3) 04:00.0 PCI bridge: nVidia Corporation PCI express bridge for Quadro Plex S4 / Tesla S870 / Tesla S1070 (rev a3) 04:02.0 PCI bridge: nVidia Corporation PCI express bridge for Quadro Plex S4 / Tesla S870 / Tesla S1070 (rev a3) 05:00.0 3D controller: nVidia Corporation G98 [Quadro NVS 450] (rev a1) 06:00.0 VGA compatible controller: nVidia Corporation G98 [Quadro NVS 450] (rev a1) 08:00.0 SATA controller: JMicron Technology Corp. JMB362/JMB363 Serial ATA Controller (rev 02) 08:00.1 IDE interface: JMicron Technology Corp. JMB362/JMB363 Serial ATA Controller (rev 02) 09:00.0 SATA controller: JMicron Technology Corp. JMB362/JMB363 Serial ATA Controller (rev 03) 09:00.1 IDE interface: JMicron Technology Corp. JMB362/JMB363 Serial ATA Controller (rev 03) 0a:00.0 Ethernet controller: Realtek Semiconductor Co., Ltd. RTL8111/8168B PCI Express Gigabit Ethernet controller (rev 06) 0b:06.0 FireWire (IEEE 1394): Texas Instruments TSB43AB23 IEEE-1394a-2000 Controller (PHY/Link)

    Read the article

  • Web Folder size/quota reporting tool?

    - by nctrnl
    I am currently using a Visual Basic script to determine how big the web folders are and what quota is decided for each folder. The quota is in no way a physical limit, just a value inserted by me to decide whether a user is using too much space or not. The script does the job quite neatly and sends an html file by mail on a regular basis. The problem is that it's such a hassle to insert new quotas since I have to fiddle around with the code. A central "control panel" with an overview and ability to insert new quotas would be more suitable. Is there any software that can do the following: Scan specified folder/subfolders Report the file size and present it in some sort of interface (could be a php/mysql solution) Ability to specify a quota and see the difference value ? It is really important that the quota handling is made simple so that some non-technician can handle this.

    Read the article

  • Web Folder size/quota reporting tool?

    - by nctrnl
    I am currently using a Visual Basic script to determine how big the web folders are and what quota is decided for each folder. The quota is in no way a physical limit, just a value inserted by me to decide whether a user is using too much space or not. The script does the job quite neatly and sends an html file by mail on a regular basis. The problem is that it's such a hassle to insert new quotas since I have to fiddle around with the code. A central "control panel" with an overview and ability to insert new quotas would be more suitable. Is there any software that can do the following: Scan specified folder/subfolders Report the file size and present it in some sort of interface (could be a php/mysql solution) Ability to specify a quota and see the difference value ? It is really important that the quota handling is made simple so that some non-technician can handle this.

    Read the article

  • Planning to buy a server with at least 48GB Ram, are the blades way to go?

    - by varchar1
    We're planning to host our website for the first time for ourselves. We have currently have a linode of 8 gigs and the memory is going up to 90% most of the time. So I want to move my website to my own server with huge RAM. So this will be first time to manage any physical hardware of a server. So I came across IBM's BladeCenter, found them interesting. So can I just buy the blade and run it? Or do I have to buy the chassis for sure? Also, do I need to buy an UPS? So how hard is it to setup? How about the hard drives? Can I setup them easily? Please advice.

    Read the article

  • Hyper-V shutdown/start up host causing issues in VMs

    - by Colin Desmond
    I have a single physical host, running 2008 R2 with Hyper-V, all fully updated. On that host I am running 3 clients, a DC, a web server and a SQL Server 2008 R2 SP1. All are running on Windows Server 2008 R2, again all fully patched. Generally all is fine, but sometimes and not repeatably, when I shutdown the host properly, which suspends the Clients, when it all comes up again, SQL Server is no longer running and the IIS App Pool I am running the website in needs to be told which account to run in again! Any ideas!?

    Read the article

  • Various problems with software raid1 array built with Samsung 840 Pro SSDs

    - by Andy B
    I am bringing to ServerFault a problem that is tormenting me for 6+ months. I have a CentOS 6 (64bit) server with an md software raid-1 array with 2 x Samsung 840 Pro SSDs (512GB). Problems: Serious write speed problems: root [~]# time dd if=arch.tar.gz of=test4 bs=2M oflag=sync 146+1 records in 146+1 records out 307191761 bytes (307 MB) copied, 23.6788 s, 13.0 MB/s real 0m23.680s user 0m0.000s sys 0m0.932s When doing the above (or any other larger copy) the load spikes to unbelievable values (even over 100) going up from ~ 1. When doing the above I've also noticed very weird iostat results: Device: rrqm/s wrqm/s r/s w/s rsec/s wsec/s avgrq-sz avgqu-sz await svctm %util sda 0.00 1589.50 0.00 54.00 0.00 13148.00 243.48 0.60 11.17 0.46 2.50 sdb 0.00 1627.50 0.00 16.50 0.00 9524.00 577.21 144.25 1439.33 60.61 100.00 md1 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 md2 0.00 0.00 0.00 1602.00 0.00 12816.00 8.00 0.00 0.00 0.00 0.00 md0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 And it keeps it this way until it actually writes the file to the device (out from swap/cache/memory). The problem is that the second SSD in the array has svctm and await roughly 100 times larger than the second. For some reason the wear is different between the 2 members of the array root [~]# smartctl --attributes /dev/sda | grep -i wear 177 Wear_Leveling_Count 0x0013 094% 094 000 Pre-fail Always - 180 root [~]# smartctl --attributes /dev/sdb | grep -i wear 177 Wear_Leveling_Count 0x0013 070% 070 000 Pre-fail Always - 1005 The first SSD has a wear of 6% while the second SSD has a wear of 30%!! It's like the second SSD in the array works at least 5 times as hard as the first one as proven by the first iteration of iostat (the averages since reboot): Device: rrqm/s wrqm/s r/s w/s rsec/s wsec/s avgrq-sz avgqu-sz await svctm %util sda 10.44 51.06 790.39 125.41 8803.98 1633.11 11.40 0.33 0.37 0.06 5.64 sdb 9.53 58.35 322.37 118.11 4835.59 1633.11 14.69 0.33 0.76 0.29 12.97 md1 0.00 0.00 1.88 1.33 15.07 10.68 8.00 0.00 0.00 0.00 0.00 md2 0.00 0.00 1109.02 173.12 10881.59 1620.39 9.75 0.00 0.00 0.00 0.00 md0 0.00 0.00 0.41 0.01 3.10 0.02 7.42 0.00 0.00 0.00 0.00 What I've tried: I've updated the firmware to DXM05B0Q (following reports of dramatic improvements for 840Ps after this update). I have looked for "hard resetting link" in dmesg to check for cable/backplane issues but nothing. I have checked the alignment and I believe they are aligned correctly (1MB boundary, listing below) I have checked /proc/mdstat and the array is Optimal (second listing below). root [~]# fdisk -ul /dev/sda Disk /dev/sda: 512.1 GB, 512110190592 bytes 255 heads, 63 sectors/track, 62260 cylinders, total 1000215216 sectors Units = sectors of 1 * 512 = 512 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x00026d59 Device Boot Start End Blocks Id System /dev/sda1 2048 4196351 2097152 fd Linux raid autodetect Partition 1 does not end on cylinder boundary. /dev/sda2 * 4196352 4605951 204800 fd Linux raid autodetect Partition 2 does not end on cylinder boundary. /dev/sda3 4605952 814106623 404750336 fd Linux raid autodetect root [~]# fdisk -ul /dev/sdb Disk /dev/sdb: 512.1 GB, 512110190592 bytes 255 heads, 63 sectors/track, 62260 cylinders, total 1000215216 sectors Units = sectors of 1 * 512 = 512 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x0003dede Device Boot Start End Blocks Id System /dev/sdb1 2048 4196351 2097152 fd Linux raid autodetect Partition 1 does not end on cylinder boundary. /dev/sdb2 * 4196352 4605951 204800 fd Linux raid autodetect Partition 2 does not end on cylinder boundary. /dev/sdb3 4605952 814106623 404750336 fd Linux raid autodetect /proc/mdstat root # cat /proc/mdstat Personalities : [raid1] md0 : active raid1 sdb2[1] sda2[0] 204736 blocks super 1.0 [2/2] [UU] md2 : active raid1 sdb3[1] sda3[0] 404750144 blocks super 1.0 [2/2] [UU] md1 : active raid1 sdb1[1] sda1[0] 2096064 blocks super 1.1 [2/2] [UU] unused devices: Running a read test with hdparm root [~]# hdparm -t /dev/sda /dev/sda: Timing buffered disk reads: 664 MB in 3.00 seconds = 221.33 MB/sec root [~]# hdparm -t /dev/sdb /dev/sdb: Timing buffered disk reads: 288 MB in 3.01 seconds = 95.77 MB/sec But look what happens if I add --direct root [~]# hdparm --direct -t /dev/sda /dev/sda: Timing O_DIRECT disk reads: 788 MB in 3.01 seconds = 262.08 MB/sec root [~]# hdparm --direct -t /dev/sdb /dev/sdb: Timing O_DIRECT disk reads: 534 MB in 3.02 seconds = 176.90 MB/sec Both tests increase but /dev/sdb doubles while /dev/sda increases maybe 20%. I just don't know what to make of this. As suggested by Mr. Wagner I've done another read test with dd this time and it confirms the hdparm test: root [/home2]# dd if=/dev/sda of=/dev/null bs=1G count=10 10+0 records in 10+0 records out 10737418240 bytes (11 GB) copied, 38.0855 s, 282 MB/s root [/home2]# dd if=/dev/sdb of=/dev/null bs=1G count=10 10+0 records in 10+0 records out 10737418240 bytes (11 GB) copied, 115.24 s, 93.2 MB/s So sda is 3 times faster than sdb. Or maybe sdb is doing also something else besides what sda does. Is there some way to find out if sdb is doing more than what sda does? UPDATE Again, as suggested by Mr. Wagner, I have swapped the 2 SSDs. And as he thought it would happen, the problem moved from sdb to sda. So I guess I'll RMA one of the SSDs. I wonder if the cage might be problematic. What is wrong with this array? Please help!

    Read the article

  • Securing a persistent reverse SSH connection for management

    - by bVector
    I am deploying demo Ubuntu 10.04 LTS servers in environments I do not control and would like to have an easy and secure way to administer these machines without having to have the destination firewall forward port 22 for SSH access. I've found a few guides to do this with reverse port (e.g. howtoforge reverse ssh tunneling guide) but I'm concerned with security of the stored ssh credentials required for the tunnel to be opened automatically. If the machine is compromised (primary concern is physical access to the machine is out of my control) how can I stop someone from using the stored credentials to poke around in the reverse ssh tunnel target machine? Is it possible to secure this setup, or would you suggest an alternate method?

    Read the article

  • Spanned volumes on new install

    - by Noio
    My Windows 7 Release Candidate is about to expire, so I'm going to do a clean install of a retail version. I have two volumes, on four physical drives, as follows: Disk 0: Spanned Volume (D:) Disk 1: Primary Partition, Boot/Windows Install (C:) Disk 2: Spanned Volume (D:) Disk 3: Spanned Volume (D:) If I install Windows to a formatted drive 1, will it still recognize the spanned volume in Disks 0, 2, and 3? The spanned volume is not redundant in any way, so the volume is 1.5TB consisting of three 500GB disks. I don't have the space to do an external backup, and I thought it was impossible to convert a spanned volume back to a basic volume.

    Read the article

  • Identify SATA hard drive

    - by Rob Nicholson
    Very similar question to: Physically Identify the failed hard drive But for Windows 2003 this time. Scenario: Four identical SATA hard drives plugged into motherboard (no RAID controller here) Configured as single drive in Windows as a spanned volume One of them is starting to fail with error "The driver detected a controller error on \Device\Harddisk3" How do you cross-reference Harddisk3 to the physical SATA connection on the motherboard so you know which drive to replace? I know replacing this drive will trash the spanned array requiring it to be rebuilt anyway so my rough and ready solution is: Delete the spanned partition Create individual partitions on each drive labelled E: F: G: and H: and work out which one is Harddisk3 Power down, remove each disk one at a time, power-up until the drive letter disappears But this seems a rather crude method of identifying the drive. The SATA connectors will be numbered on the motherboard but I appreciate this might not cross-match to what Windows calls them. Thanks, Rob.

    Read the article

  • Can a power failure or forceful shutdown damage hardware?

    - by Vilx-
    Can computer hardware suffer damage from forceful shutdowns (holding the power button for five (5) seconds) or power failures? I believe that normal PC hardware does not suffer from this - after all, it's not much different than what they experience under a standard shutdown. But elsewhere I've read tht another person thought that it could do physical harm to the hard drive and possibly other components as well. He also said that the journaling features of filesystems are useless in face of power failures and were intended to help mitigate damage from system crashes. I think this is nonsense, but then again I lack the experience and knowledge to say it with certainty.

    Read the article

  • Dell Power Edge R515 - Replacing a Bad Hard Drive in a RAID

    - by LonnieBest
    I've ordered a new hard drive to replace a bad one in a Dell Power Edge R515. The manual covers obvious topics regarding physical replacing of hard drives, but I've never done this before on a production server where RAID is involved. I've heard people talk about this topic, and I've heard that some servers have RAID controllers that are smart enough to allow you to just put in the new drive (hot swap), and then the server will know automatically how to rebuild that drive to be what the old one was to the system. Where do I find the proper procedure for replacing a failed hard drive on a live production Dell Power Edge R515? Can someone with experience tell me how easy or hard this usually is?

    Read the article

  • How do I make a virtualised WAN?

    - by EnchantedEggs
    I want to create a virtualised WAN. As in, I want to have a couple of VMs (VBox) on one physical host machine, that exist on separate LANs, but that can talk to each other. Do I make the VMs, set them up with different IP addresses (e.g. 1.2.3.4 and 5.6.7.8) and then configure port forwarding between them somehow??? I've seen articles that set up port forwarding on port 2222, but I don't really understand why this works. How is setting up the VM to listen to port 2222 and then port forward from there to, say, port 80, any different from just telling the VM to listen on port 80 in the first place? FYI, the VMs run Ubuntu Desktop 14.x.

    Read the article

  • The cd command using variable to mapped NFS volume within ssh in linux script is not working

    - by Bhavya Maheshwari
    I have to do the following from within a bash script. The /VMNFS/ folder is present on linux box, from where script is run, and is mapped to the machine into which i am ssh'ing, as an NFS at /vmfs/volumes/VMNFS/. The second cd command doesn't work, neither with symbolic path name nor physical pathname. Why? and How to rectify this? #!/bin/bash ssh -2 [email protected] /bin/sh <<\EOF vmfile_path=`grep / vmvar_file` datastore_path=/vmfs/volumes/VMNFS/ cd $datastore_path && echo "The present working directory is" `pwd -P` esxi_vmfile_path_sub=`pwd -P` && echo "variable value is" $esxi_vmfile_path_sub esxi_vmfile_path=`echo $vmfile_path | sed "s:/VMNFS:$esxi_vmfile_path_sub:"` cd "$esxi_vmfile_path" EOF ***Output***: The current working directory is /vmfs/volumes/65335ec4-46d12e41 variable value is /vmfs/volumes/65335ec4-46d12e41 can't cd to /vmfs/volumes/65335ec4-46d12e41/TPAE7.5/

    Read the article

  • PostgreSQL RAID configuration

    - by Yoldar-Zi
    I'm stuck how best to configure disk array. We have Hp P2000 G3 disk array with 24 SAS physical disks 300Gb each. We need to configure this array got 2 copies of PostgreSQL 9.2 because two different system. As we know it's recommended to store database and transaction logs(pg_xlog) files on separate disks. So we must setup 4 logical disk: 2 for transaction logs with RAID 1 2 for database with RAID 10 Is this right scheme of distribution? Or may be it is best to just make one big RAID 10 with 4 logical disks?

    Read the article

  • Debian 5 is randomly shutting down.

    - by revofreak
    My debian 5 vps is suffering from random shutdowns. I reinstalled it several times, the hosts moved me to a different physical box, check the install image and said everyone else also uses it and is fine. Heres the output from syslog Mar 27 00:19:19 noobintraining-1 -- MARK -- Mar 27 00:32:01 noobintraining-1 shutdown[18142]: shutting down for system halt Mar 27 00:32:06 noobintraining-1 init: Switching to runlevel: 0 Mar 27 00:32:06 noobintraining-1 xinetd[15907]: Exiting... Mar 27 00:32:07 noobintraining-1 named[15865]: received control channel command 'stop -p' Mar 27 00:32:07 noobintraining-1 named[15865]: shutting down: flushing changes Mar 27 00:32:07 noobintraining-1 named[15865]: stopping command channel on 127.0.0.1#953 Mar 27 00:32:07 noobintraining-1 named[15865]: stopping command channel on ::1#953 Mar 27 00:32:07 noobintraining-1 named[15865]: no longer listening on ::#53 Mar 27 00:32:07 noobintraining-1 named[15865]: no longer listening on 127.0.0.1#53 Mar 27 00:32:07 noobintraining-1 named[15865]: no longer listening on 89.238.172.132#53 Mar 27 00:32:07 noobintraining-1 named[15865]: exiting Mar 27 00:32:07 noobintraining-1 exiting on signal 15 Any help is most appreciated!

    Read the article

  • VMware two vSwitches Guests can't communicate between them

    - by Aaron R.
    I have some servers in this configuration: And I am not able, from VMGuest1, to ping either VMGuest3 or VMGuest4. I can, however, ping Host1 and Host2, which are attached to pSwitch1. The behavior is the same with VMGuest3 or 4 trying to ping VMGuest 1 or 2. I don't have promiscuity enabled for any of these switches, nor do I have a bridge set up inside ESXi for the virtual switches. I know that one of these options is usually necessary when trying to get connectivity between two virtual switches. These switches are connected, however, through their respective physical switches which are bridged together. Ping just times out, arp request looks like this: [root@vmguest1:~]# arp -a vmguest3 vmguest3.example.com (1.2.3.4) at <incomplete> on eth0 [root@vmguest1:~]# arp -a host1 host1.example.com (1.2.3.5) at 00:0C:64:97:1C:FF [ether] on eth0 VMGuest1 can reach hosts on pSwitch1, so why can't it get to hosts on vSwitch1 through pSwitch1 the same way?

    Read the article

  • how to copy sql server database on same server

    - by Sam
    I've got a SQL Server 2008 and want to make a copy of a database so I've got a 2nd Version of the database for testing on the same server. The database copy wizard is not able to copy the database, it always sends funny error Messages about missing objects (using SMO copy). When I try to make a backup and restore it under a different database name it still keeps the file names of the original database and overrides this (crashing the original database). So how do I copy a SQL database? Shutdown SQL Server, copy the physical files and attach them? Maybe a command line tool for database copy? Shouldn't there be an easy way to make a copy?

    Read the article

  • How to change the amount of RAM displayed in System Properties

    - by Nicu Zecheru
    I have this product that requires at least 1 GB Physical Memory in order to be installed. On my XP Pro machine I have 1 GB of RAM but in System Properties only 0.99 GB of RAM is displayed. The problem is that the product installer checks the memory displayed in System Properties (just a guess, not sure) and cannot continue the setup because it sees only 0.99 GB. Is there any way to change the displayed memory in the System Properties? Or how can I trick the installer to skip the memory check? Thanks.

    Read the article

< Previous Page | 71 72 73 74 75 76 77 78 79 80 81 82  | Next Page >