Search Results

Search found 4834 results on 194 pages for 'dr unix'.

Page 76/194 | < Previous Page | 72 73 74 75 76 77 78 79 80 81 82 83  | Next Page >

  • Problem: Sorting for GridView/ObjectDataSource changes depending on page

    - by user148298
    I have a GridView tied to an ObjectDataSource using paging. The paging works fine, except that the sort order changes depending on which page of the results is being viewed. This causes items to reappear on subsequent pages among other issues. I traced the problem to my DAL, which reads a page at a time and then sorts it. Obviously the sorting is going to change as the result set size changes. Is there an improvement to this algorithm. I would like to use a datareader if possible: [System.ComponentModel.DataObjectMethod(System.ComponentModel.DataObjectMethodType.Select)] public static WordsCollection LoadForCriteria(string sqlCriteria, int maximumRows, int startRowIndex, string sortExpression) { //DEFAULT SORT EXPRESSION if (string.IsNullOrEmpty(sortExpression)) sortExpression = "OrderBy"; //CREATE THE DYNAMIC SQL TO LOAD OBJECT StringBuilder selectQuery = new StringBuilder(); selectQuery.Append("SELECT"); if (maximumRows > 0) selectQuery.Append(" TOP " + (startRowIndex + maximumRows).ToString()); selectQuery.Append(" " + Words.GetColumnNames(string.Empty)); selectQuery.Append(" FROM sw_Words"); string whereClause = string.IsNullOrEmpty(sqlCriteria) ? string.Empty : " WHERE " + sqlCriteria; selectQuery.Append(whereClause); selectQuery.Append(" ORDER BY " + sortExpression); Database database = Token.Instance.Database; DbCommand selectCommand = database.GetSqlStringCommand(selectQuery.ToString()); //EXECUTE THE COMMAND WordsCollection results = new WordsCollection(); int thisIndex = 0; int rowCount = 0; using (IDataReader dr = database.ExecuteReader(selectCommand)) { while (dr.Read() && ((maximumRows < 1) || (rowCount < maximumRows))) { if (thisIndex >= startRowIndex) { Words varWords = new Words(); Words.LoadDataReader(varWords, dr); results.Add(varWords); rowCount++; } thisIndex++; } dr.Close(); } return results; }

    Read the article

  • How can I read a DBF file with incorrectly defined column data types using ADO.NET?

    - by Jason
    I have a several DBF files generated by a third party that I need to be able to query. I am having trouble because all of the column types have been defined as characters, but the data within some of these fields actually contain binary data. If I try to read these fields using an OleDbDataReader as anything other than a string or character array, I get an InvalidCastException thrown, but I need to be able to read them as a binary value or at least cast/convert them after they are read. The columns that actually DO contain text are being returned as expected. For example, the very first column is defined as a character field with a length of 2 bytes, but the field contains a 16-bit integer. I have written the following test code to read the first column and convert it to the appropriate data type, but the value is not coming out right. The first row of the database has a value of 17365 (0x43D5) in the first column. Running the following code, what I end up getting is 17215 (0x433F). I'm pretty sure it has to do with using the ASCII encoding to get the bytes from the string returned by the data reader, but I'm not sure of another way to get the value into the format that I need, other that to write my own DBF reader and bypass ADO.NET altogether which I don't want to do unless I absolutely have to. Any help would be greatly appreciated. byte[] c0; int i0; string con = @"Provider=Microsoft.Jet.OLEDB.4.0;Data Source=C:\ASTM;Extended Properties=dBASE III;User ID=Admin;Password=;"; using (OleDbConnection c = new OleDbConnection(con)) { c.Open(); OleDbCommand cmd = c.CreateCommand(); cmd.CommandText = "SELECT * FROM astm2007"; OleDbDataReader dr = cmd.ExecuteReader(); while (dr.Read()) { c0 = Encoding.ASCII.GetBytes(dr.GetValue(0).ToString()); i0 = BitConverter.ToInt16(c0, 0); } dr.Dispose(); }

    Read the article

  • How to pass a value from a method to property procedure in c#?

    - by sameer
    Here is my code: The jewellery class is my main class in which i am inheriting a connection string class. class Jewellery : Connectionstr { string lmcode; public string LM_code/**/Here i want to access the value of the method ReadData i.e displaystring and i want to store this value in the insert query below.** { get { return lmcode; } set { lmcode = value; } } string mname; public string M_Name { get { return mname; } set { mname = value; } } string desc; public string Desc { get { return desc; } set { desc = value; } } public string ReadData() { OleDbDataReader dr; string jid = string.Empty; string displayString = string.Empty; String query = "select max(LM_code)from Master_Accounts"; Datamanager.RunExecuteReader(Constr, query); if (dr.Read()) { jid = dr[0].ToString(); if (string.IsNullOrEmpty(jid)) { jid = "AM0000"; } int len = jid.Length; string split = jid.Substring(2, len - 2); int num = Convert.ToInt32(split); num++; displayString = jid.Substring(0, 2) + num.ToString("0000"); dr.Close(); } **return displayString;** I want to pass this value to the above property procedure above i.e LM_code. } public void add() { String query ="insert into Master_Accounts values ('" + LM_code + "','" + M_Name + "'," + "'" + Desc + "')"; Datamanager.RunExecuteNonQuery(Constr , query);// } If possible can u edit this code! Anticipated thanks by sameer

    Read the article

  • Procedure or function AppendDataCT has too many arguments specified

    - by salvationishere
    I am developing a C# VS 2008 / SQL Server website application. I am a newbie to ASP.NET. I am getting the above compiler error. Can you give me advice on how to fix this? Code snippet: public static string AppendDataCT(DataTable dt, Dictionary<int, string> dic) { string connString = ConfigurationManager.ConnectionStrings["AW3_string"].ConnectionString; string errorMsg; try { SqlConnection conn2 = new SqlConnection(connString); SqlCommand cmd = conn2.CreateCommand(); cmd.CommandText = "dbo.AppendDataCT"; cmd.CommandType = CommandType.StoredProcedure; cmd.Connection = conn2; SqlParameter p1, p2, p3; foreach (string s in dt.Rows[1].ItemArray) { DataRow dr = dt.Rows[1]; // second row p1 = cmd.Parameters.AddWithValue((string)dic[0], (string)dr[0]); p1.SqlDbType = SqlDbType.VarChar; p2 = cmd.Parameters.AddWithValue((string)dic[1], (string)dr[1]); p2.SqlDbType = SqlDbType.VarChar; p3 = cmd.Parameters.AddWithValue((string)dic[2], (string)dr[2]); p3.SqlDbType = SqlDbType.VarChar; } conn2.Open(); cmd.ExecuteNonQuery(); It errors on this last line here. And here is that SP: ALTER PROCEDURE [dbo].[AppendDataCT] @col1 VARCHAR(50), @col2 VARCHAR(50), @col3 VARCHAR(50) AS BEGIN SET NOCOUNT ON; DECLARE @TEMP DATETIME SET @TEMP = (SELECT CONVERT (DATETIME, @col3)) INSERT INTO Person.ContactType (Name, ModifiedDate) VALUES( @col2, @TEMP) END

    Read the article

  • Bind SQLiteDataReader to GridView in ASP.NET

    - by Charles Gargent
    Hi, this is all rather new to me, but I have searched for a good while and cant find any idea why I cant get this to work, dr looks like it is populated but I get this nullreferenceexeception when I try to bind to the gridview Thanks code SQLiteConnection cnn = new SQLiteConnection(@"Data Source=c:\log.db"); cnn.Open(); SQLiteCommand cmd = new SQLiteCommand(@"SELECT * FROM evtlog", cnn); SQLiteDataReader dr = cmd.ExecuteReader(); GridView1.DataSource = dr; GridView1.DataBind(); dr.Close(); cnn.Close(); Codebehind <asp:ContentPlaceHolder ID="MainContent" runat="server"> <asp:GridView ID="GridView1" runat="server"> </asp:GridView> </asp:ContentPlaceHolder> error Object reference not set to an instance of an object. at WPKG_Report.SiteMaster.Button1_Click(Object sender, EventArgs e) in C:\Projects\Report\Site.Master.cs:line 32 at System.Web.UI.WebControls.Button.OnClick(EventArgs e) at System.Web.UI.WebControls.Button.RaisePostBackEvent(String eventArgument) at System.Web.UI.WebControls.Button.System.Web.UI.IPostBackEventHandler.RaisePostBackEvent(String eventArgument) at System.Web.UI.Page.RaisePostBackEvent(IPostBackEventHandler sourceControl, String eventArgument) at System.Web.UI.Page.RaisePostBackEvent(NameValueCollection postData) at System.Web.UI.Page.ProcessRequestMain(Boolean includeStagesBeforeAsyncPoint, Boolean includeStagesAfterAsyncPoint)

    Read the article

  • Violation of PRIMARY KEY constraint 'PK_

    - by abhi
    hi am trying to write a code in which i need to perform a update but on primary keys how do i achieve it i have written the following code: kindly look at it let me know where m wrong Protected Sub rgKMSLoc_UpdateCommand(ByVal source As Object, ByVal e As Telerik.Web.UI.GridCommandEventArgs) Handles rgKMSLoc.UpdateCommand Try KAYAReqConn.Open() If TypeOf e.Item Is GridEditableItem Then Dim strItemID As String = CType(e.Item.FindControl("hdnID"), HiddenField).Value Dim strrcmbLocation As String = CType(e.Item.FindControl("rcmbLocation"), RadComboBox).SelectedValue Dim strKubeLocation As String = CType(e.Item.FindControl("txtKubeLocation"), TextBox).Text Dim strCSVCode As String = CType(e.Item.FindControl("txtCSVCode"), TextBox).Text SQLCmd = New SqlCommand("SELECT * FROM MstKMSLocKubeLocMapping WHERE LocationID= '" & rcmbLocation.SelectedValue & "'", KAYAReqConn) Dim dr As SqlDataReader dr = SQLCmd.ExecuteReader If dr.HasRows Then lblMsgWarning.Text = "<font color=red>""User ID Already Exists" Exit Sub End If dr.Close() SQLCmd = New SqlCommand("UPDATE MstKMSLocKubeLocMapping SET LocationID=@Location,KubeLocation=@KubeLocation,CSVCode=@CSVCode WHERE LocationID = '" & strItemID & "'", KAYAReqConn) SQLCmd.Parameters.AddWithValue("@Location", Replace(strrcmbLocation, "'", "''")) SQLCmd.Parameters.AddWithValue("@KubeLocation", Replace(strKubeLocation, "'", "''")) SQLCmd.Parameters.AddWithValue("@CSVCode", Replace(strCSVCode, "'", "''")) SQLCmd.Parameters.AddWithValue("@Status", "A") SQLCmd.ExecuteNonQuery() lblMessageUpdate.Text = "<font color=blue>""Record Updated SuccessFully" SQLCmd.Dispose() rgKMSLoc.Rebind() End If Catch ex As Exception Response.Write(ex.ToString) Finally KAYAReqConn.Close() End Try End Sub this is my designer page' Location: ' / ' DataSourceID="dsrcmbLocation" DataTextField="Location" DataValueField="LocationID" Height="150px" Kube Location: ' Class="forTextBox" MaxLength="4" onkeypress="return filterInput(2,event);" CSV Code: ' Class="forTextBox" MaxLength="4" onkeypress="return filterInput(2,event);" <tr class="tableRow"> <td colspan="2" align="center" class="tableCell"> <asp:ImageButton ID="btnUpdate" runat="server" CommandName="Update" CausesValidation="true" ValidationGroup="Update" ImageUrl="~/Images/update.gif"></asp:ImageButton> <asp:ImageButton ID="btnCancel" runat="server" CausesValidation="false" CommandName="Cancel" ImageUrl="~/Images/No.gif"></asp:ImageButton> </td> </tr> </table> </FormTemplate> </EditFormSettings> Locationid is my primary key

    Read the article

  • Binding ListBox ItemCount to IvalueConverter

    - by Ben
    Hi All, I am fairly new to WPF so forgive me if I am missing something obvious. I'm having a problem where I have a collection of AggregatedLabels and I am trying to bind the ItemCount of each AggregatedLabel to the FontSize in my DataTemplate so that if the ItemCount of an AggregatedLabel is large then a larger fontSize will be displayed in my listBox etc. The part that I am struggling with is the binding to the ValueConverter. Can anyone assist? Many thanks! XAML Snippet <DataTemplate x:Key="TagsTemplate"> <WrapPanel> <TextBlock Text="{Binding Name, Mode=Default}" TextWrapping="Wrap" FontSize="{Binding ItemCount, Converter={StaticResource CountToFontSizeConverter}, Mode=Default}" Foreground="#FF0D0AF7"/> </WrapPanel> </DataTemplate> <ListBox x:Name="tagsList" ItemsSource="{Binding AggregatedLabels, Mode=Default}" ItemTemplate="{StaticResource TagsTemplate}" Style="{StaticResource tagsStyle}" Margin="200,10,16.171,11.88" /> AggregatedLabel Collection using (DB2DataReader dr = command.ExecuteReader()) { while (dr.Read()) { AggregatedLabelModel aggLabel = new AggregatedLabelModel(); aggLabel.ID = Convert.ToInt32(dr["LABEL_ID"]); aggLabel.Name = dr["LABEL_NAME"].ToString(); LabelData.Add(aggLabel); } } Converter public class CountToFontSizeConverter : IValueConverter { #region IValueConverter Members public object Convert(object value, Type targetType, object parameter, System.Globalization.CultureInfo culture) { const int minFontSize = 6; const int maxFontSize = 38; const int increment = 3; int count = (int)value; if ((minFontSize + count + increment) < maxFontSize) { return minFontSize + count + increment; } return maxFontSize; } public object ConvertBack(object value, Type targetType, object parameter, System.Globalization.CultureInfo culture) { throw new NotImplementedException(); } #endregion } AggregatedLabel Class public class AggregatedLabelModel { public int ID { get; set; } public string Name { get; set; } } CollectionView ListCollectionView labelsView = new ListCollectionView(LabelData); labelsView.GroupDescriptions.Add(new PropertyGroupDescription("Name"));

    Read the article

  • using the ASP.NET Caching API via method annotations in C#

    - by craigmoliver
    In C#, is it possible to decorate a method with an annotation to populate the cache object with the return value of the method? Currently I'm using the following class to cache data objects: public class SiteCache { // 7 days + 6 hours (offset to avoid repeats peak time) private const int KeepForHours = 174; public static void Set(string cacheKey, Object o) { if (o != null) HttpContext.Current.Cache.Insert(cacheKey, o, null, DateTime.Now.AddHours(KeepForHours), TimeSpan.Zero); } public static object Get(string cacheKey) { return HttpContext.Current.Cache[cacheKey]; } public static void Clear(string sKey) { HttpContext.Current.Cache.Remove(sKey); } public static void Clear() { foreach (DictionaryEntry item in HttpContext.Current.Cache) { Clear(item.Key.ToString()); } } } In methods I want to cache I do this: [DataObjectMethod(DataObjectMethodType.Select)] public static SiteSettingsInfo SiteSettings_SelectOne_Name(string Name) { var ck = string.Format("SiteSettings_SelectOne_Name-Name_{0}-", Name.ToLower()); var dt = (DataTable)SiteCache.Get(ck); if (dt == null) { dt = new DataTable(); dt.Load(ModelProvider.SiteSettings_SelectOne_Name(Name)); SiteCache.Set(ck, dt); } var info = new SiteSettingsInfo(); foreach (DataRowView dr in dt.DefaultView) info = SiteSettingsInfo_Load(dr); return info; } Is it possible to separate those concerns like so: (notice the new annotation) [CacheReturnValue] [DataObjectMethod(DataObjectMethodType.Select)] public static SiteSettingsInfo SiteSettings_SelectOne_Name(string Name) { var dt = new DataTable(); dt.Load(ModelProvider.SiteSettings_SelectOne_Name(Name)); var info = new SiteSettingsInfo(); foreach (DataRowView dr in dt.DefaultView) info = SiteSettingsInfo_Load(dr); return info; }

    Read the article

  • Escape Quote in C# for javascript consumption

    - by Jason
    I have a ASP.Net web handler that returns results of a query in JSON format public static String dt2JSON(DataTable dt) { String s = "{\"rows\":["; if (dt.Rows.Count > 0) { foreach (DataRow dr in dt.Rows) { s += "{"; for (int i = 0; i < dr.Table.Columns.Count; i++) { s += "\"" + dr.Table.Columns[i].ToString() + "\":\"" + dr[i].ToString() + "\","; } s = s.Remove(s.Length - 1, 1); s += "},"; } s = s.Remove(s.Length - 1, 1); } s += "]}"; return s; } The problem is that sometimes the data returned has quotes in it and I would need to javascript-escape these so that it can be properly created into a js object. I need a way to find quotes in my data (quotes aren't there every time) and place a "/" character in front of them. Example response text (wrong): {"rows":[{"id":"ABC123","length":"5""}, {"id":"DEF456","length":"1.35""}, {"id":"HIJ789","length":"36.25""}]} I would need to escape the " so my response should be: {"rows":[{"id":"ABC123","length":"5\""}, {"id":"DEF456","length":"1.35\""}, {"id":"HIJ789","length":"36.25\""}]} Also, I'm pretty new to C# (coding in general really) so if something else in my code looks silly let me know.

    Read the article

  • Perl Regex - Condensing groups of find/replace

    - by brydgesk
    I'm using Perl to perform some file cleansing, and am running into some performance issues. One of the major parts of my code involves standardizing name fields. I have several sections that look like this: sub substitute_titles { my ($inStr) = @_; ${$inStr} =~ s/ PHD./ PHD /; ${$inStr} =~ s/ P H D / PHD /; ${$inStr} =~ s/ PROF./ PROF /; ${$inStr} =~ s/ P R O F / PROF /; ${$inStr} =~ s/ DR./ DR /; ${$inStr} =~ s/ D.R./ DR /; ${$inStr} =~ s/ HON./ HON /; ${$inStr} =~ s/ H O N / HON /; ${$inStr} =~ s/ MR./ MR /; ${$inStr} =~ s/ MRS./ MRS /; ${$inStr} =~ s/ M R S / MRS /; ${$inStr} =~ s/ MS./ MS /; ${$inStr} =~ s/ MISS./ MISS /; } I'm passing by reference to try and get at least a little speed, but I fear that running so many (literally hundreds) of specific string replaces on tens of thousands (likely hundreds of thousands eventually) of records is going to hurt the performance. Is there a better way to implement this kind of logic than what I'm doing currently? Thanks Edit: Quick note, not all the replace functions are just removing periods and spaces. There are string deletions, soundex groups, etc.

    Read the article

  • C# ASP.NET Binding Controls via Generic Method

    - by OverTech
    I have a few web applications that I maintain and I find myself very often writing the same block of code over and over again to bind a GridView to a data source. I'm trying to create a Generic method to handle data binding but I'm having trouble getting it to work with Repeaters and DataLists. Here is the Generic method I have so far: public void BindControl<T>(T control, SqlCommand sql) where T : System.Web.UI.WebControls.BaseDataBoundControl { cmd = sql; cn.Open(); SqlDataReader dr = cmd.ExecuteReader(); if (dr.HasRows) { control.DataSource = dr; control.DataBind(); } dr.Close(); cn.Close(); } That way I can just define my CommandText then make a call to "BindControls(myGridView, cmd)" instead of retyping this same basic block of code every time I need to bind a grid. The problem is, this doesn't work with Repeaters or DataLists. Each of these controls inherit their respective "DataSource" and "DataBind" methods from different classes. Someone on another forum suggested that I implement an interface, but I'm not sure how to make that work either. The GridView, Datalist and Repeater get their respective "DataBind" methods from BaseDataBoundControl, BaseDataList, and Repeater classes. How would I go about creating a single interface to tie them all together? Or am I better off just using 3 overloads for this method? Dave

    Read the article

  • Pump Messages During Long Operations + C# (it is urgent)

    - by Newbie
    Hi I have a web service that is doing huge computation and is taking more than a minute. I have generated the proxy file of the web service and then from my client end I am using the dll(of course I generated the proxy dll). My client side code is TimeSeries3D t = new TimeSeries3D(); int portfolioId = 4387919; string[] str = new string[2]; str[0] = "MKT_CAP"; DateRange dr = new DateRange(); dr.mStartDate = DateTime.Today; dr.mEndDate = DateTime.Today; Service1 sc = new Service1(); t = sc.GetAttributesForPortfolio(portfolioId, true, str, dr); But since it is taking to much time for the server to compute, after 1 minute I am receiving an error message The CLR has been unable to transition from COM context 0x33caf30 to COM context 0x33cb0a0 for 60 seconds. The thread that owns the destination context/apartment is most likely either doing a non pumping wait or processing a very long running operation without pumping Windows messages. This situation generally has a negative performance impact and may even lead to the application becoming non responsive or memory usage accumulating continually over time. To avoid this problem, all single threaded apartment (STA) threads should use pumping wait primitives (such as CoWaitForMultipleHandles) and routinely pump messages during long running operations. Kindly guide me what to do? It is very urgent. Thanks

    Read the article

  • insert data to table based on another table C#

    - by user1017315
    I wrote a code which takes some values from one table and inserts the other table in these values.(not just these values, but also these values(this values=values from the based on table)) and I get this error: System.Data.OleDb.OleDbException (0x80040E10): value wan't given for one or more of the required parameters.` here's the code. I don't know what i've missed. string selectedItem = comboBox1.SelectedItem.ToString(); Codons cdn = new Codons(selectedItem); string codon1; int index; if (this.i != this.counter) { //take from the DataBase the matching codonsCodon1 to codonsFullName codon1 = cdn.GetCodon1(); //take the serialnumber of the last protein string connectionString = "Provider=Microsoft.ACE.OLEDB.12.0;" + "Data Source=C:\\Projects_2012\\Project_Noam\\Access\\myProject.accdb"; OleDbConnection conn = new OleDbConnection(connectionString); conn.Open(); string last= "SELECT proInfoSerialNum FROM tblProInfo WHERE proInfoScienceName = "+this.name ; OleDbCommand getSerial = new OleDbCommand(last, conn); OleDbDataReader dr = getSerial.ExecuteReader(); dr.Read(); index = dr.GetInt32(0); //add the amino acid to tblOrderAA using (OleDbConnection connection = new OleDbConnection(connectionString)) { string insertCommand = "INSERT INTO tblOrderAA(orderAASerialPro, orderAACodon1) " + " values (?, ?)"; using (OleDbCommand command = new OleDbCommand(insertCommand, connection)) { connection.Open(); command.Parameters.AddWithValue("orderAASerialPro", index); command.Parameters.AddWithValue("orderAACodon1", codon1); command.ExecuteNonQuery(); } } } EDIT:I put a messagebox after that line: index = dr.GetInt32(0); to see where is the problem, and i get the error before that.i don't see the messagebox

    Read the article

  • Pump Messages During Long Operations + C#

    - by Newbie
    Hi I have a web service that is doing huge computation and is taking more than a minute. I have generated the proxy file of the web service and then from my client end I am using the dll(of course I generated the proxy dll). My client side code is TimeSeries3D t = new TimeSeries3D(); int portfolioId = 4387919; string[] str = new string[2]; str[0] = "MKT_CAP"; DateRange dr = new DateRange(); dr.mStartDate = DateTime.Today; dr.mEndDate = DateTime.Today; Service1 sc = new Service1(); t = sc.GetAttributesForPortfolio(portfolioId, true, str, dr); But since it is taking to much time for the server to compute, after 1 minute I am receiving an error message The CLR has been unable to transition from COM context 0x33caf30 to COM context 0x33cb0a0 for 60 seconds. The thread that owns the destination context/apartment is most likely either doing a non pumping wait or processing a very long running operation without pumping Windows messages. This situation generally has a negative performance impact and may even lead to the application becoming non responsive or memory usage accumulating continually over time. To avoid this problem, all single threaded apartment (STA) threads should use pumping wait primitives (such as CoWaitForMultipleHandles) and routinely pump messages during long running operations. Kindly guide me what to do? Thanks

    Read the article

  • How do I access Dictionary items?

    - by salvationishere
    I am developing a C# VS2008 / SQL Server website app and am new to the Dictionary class. Can you please advise on best method of accomplishing this? Here is a code snippet: SqlConnection conn2 = new SqlConnection(connString); SqlCommand cmd = conn2.CreateCommand(); cmd.CommandText = "dbo.AppendDataCT"; cmd.CommandType = CommandType.StoredProcedure; cmd.Connection = conn2; SqlParameter p1, p2, p3; foreach (string s in dt.Rows[1].ItemArray) { DataRow dr = dt.Rows[1]; // second row p1 = cmd.Parameters.AddWithValue((string)dic[0], (string)dr[0]); p1.SqlDbType = SqlDbType.VarChar; p2 = cmd.Parameters.AddWithValue((string)dic[1], (string)dr[1]); p2.SqlDbType = SqlDbType.VarChar; p3 = cmd.Parameters.AddWithValue((string)dic[2], (string)dr[2]); p3.SqlDbType = SqlDbType.VarChar; } but this is giving me compiler error: The best overloaded method match for 'System.Collections.Generic.Dictionary<string,string>.this[string]' has some invalid arguments I just want to access each value from "dic" and load into these SQL parameters. How do I do this? Do I have to enter the key? The keys are named "col1", "col2", etc., so not the most user-friendly. Any other tips? Thanks!

    Read the article

  • How to load the SQL data into several ComboBox easily, am i doing the correctly or is there another way

    - by Dominic Deepan.d
    I have a Combobox to fill the data for City, State and PinCode these combobox is dopdown list and the user will pick it. and it loads once the form opens. Here is the CODE: /// CODE TO BRING A DATA FROM SQL INTO THE FORM DROP LIST /// To fill the sates from States Table cn = new SqlConnection(@"Data Source=Nick-PC\SQLEXPRESS;Initial Catalog=AutoDB;Integrated Security=True"); cmd= new SqlCommand("select * from TblState",cn); cn.Open(); SqlDataReader dr; try { dr = cmd.ExecuteReader(); while (dr.Read()) { SelectState.Items.Add(dr["State"].ToString()); } } catch (Exception ex) { MessageBox.Show(ex.Message); } finally { cn.Close(); } //To fill the Cities from City Table cn1 = new SqlConnection(@"Data Source=Nick-PC\SQLEXPRESS;Initial Catalog=AutoDB;Integrated Security=True"); cmd1 = new SqlCommand("SELECT * FROM TblCity", cn); cn.Open(); SqlDataReader ds; try { ds = cmd1.ExecuteReader(); while (ds.Read()) { SelectCity.Items.Add(ds["City"].ToString()); } } catch (Exception ex) { MessageBox.Show(ex.Message); } finally { cn1.Close(); } // To fill the Data in the Pincode from the City Table cn2 = new SqlConnection(@"Data Source=Nick-PC\SQLEXPRESS;Initial Catalog=AutoDB;Integrated Security=True"); cmd2 = new SqlCommand("SELECT (Pincode) FROM TblCity ", cn2); cn2.Open(); SqlDataReader dm; try { dm = cmd2.ExecuteReader(); while (dm.Read()) { SelectPinCode.Items.Add(dm["Pincode"].ToString()); } } catch (Exception ex) { MessageBox.Show(ex.Message); } finally { cn2.Close(); } its kinda Big, i am doing the same steps for all the combo-box, but is there a way i can merge it in a simple way.

    Read the article

  • Xenserver 5.5 U2 a bit unstable with an unstable W2003 VM

    - by twistedbrain
    In the last week I had to reboot the host system twice and the second one by means of the power button. The system is a Dell PE 6950 (4 Opteron dual core, 2,8 Ghz, 16 GB RAM, 900 GB disk in a RAID 10 array composed by 4 450GB 15000 rpm disks) with XenServer 5.5 U2. We're installing it and at now there are working in production a 2003 32 bit Windows server VM with 2 GB RAM, 3 vcpu and about 200 GB disk in 4 partition (12 GB boot, 20 GB program, 80 GB user data, 80 GB other data). The first time I was compressing many Windows 2003 folders (some tens GB by means of W2003 compressed folder option) from a Windows remote console and some hours before my colleague installed Backup Exec agent that was alredy installed and that required a reboot (that was pending). The console stopped responding, it was no more possible to connect by means of remote console or by means of the console of the XenCentre, it was still possible from the network to use the shared folder of the VM and the programs on it (2 db and a GIS program), but the print server didn't work any more and I couldn't give remote reboot from other domain controller hosts. I couldn't stop the virtual machine neither from the XenCentre, neither from the command line of the host also forcing the reboot. I had to reboot the host server. Yesterday it has been worst. I installed a template of another VM, CentOS 5.3 and then, put the DVD in the drive of the host. Then, before the install and after the boot I checked for defect the DVD and the W2003 VM began to respond slowly (I was connected by means of an administration remote console) the task manager showed only mid or low load, it is, only the first of the 3 vcpu was loaded (about 70%), while the other two were about at 20% and also the disk I/O was not so heavy. Then the users were not so happy because they couldn't any more use the MS word docs on the server. I immediately stopped the check of the DVD (to do that I had to force the stop of such Centos 5.3 VM), then some users could again use their docs, but other had still problems, so I decided to reboot the VM, but it doesn't stopped, neither from XenCenter, neither from command line, neither forcing the reboot. Then I tried to reboot of the host, but it didn't worked, neither from the XenCentre, neither from the host prompt (shutdown -r now as root: it told that it was shutting down, but then it didn't did that). So I had to power off by means of the power button of the server (before I tried some Magic SyS REQ, but I saw that Xen isn't compiled with this option enabled). What could you suggest about my problem, what can I look, search and see? In the W2003 VM logs there are no errors or warning to explain what happened. Some more exciting, amusing and inspiring words of poetry (the facts happened around 11 am): \# egrep -i 'err|warning' xensource.log [20100219 10:32:05.597|debug|culo|6301 unix-RPC|VBD.plug R:c81bcda701f6|xenops] watch: watching xenstore paths: [ /xapi/0/frontend/vbd/51712/hotplug; /local/domain/0/backend/vbd/0/51712/tapdisk-error ] with timeout 1200.000000 seconds [20100219 10:32:05.597|debug|culo|6301 unix-RPC|VBD.plug R:c81bcda701f6|xenops] watch: fired on /local/domain/0/backend/vbd/0/51712/tapdisk-error [20100219 10:32:14.314|debug|culo|6335 unix-RPC|VBD.unplug R:9258f54578d6|xenops] watch: watching xenstore paths: [ /local/domain/0/backend/vbd/0/51712/shutdown-done; /local/domain/0/error/device/vbd/51712/error ] with timeout 1200.000000 seconds [20100219 10:32:14.337|debug|culo|6335 unix-RPC|VBD.unplug R:9258f54578d6|xenops] xenstore-rm /local/domain/0/error/backend/vbd/0 [20100219 10:32:14.337|debug|culo|6335 unix-RPC|VBD.unplug R:9258f54578d6|xenops] xenstore-rm /local/domain/0/error/device/vbd/51712 [20100219 10:32:14.338|debug|culo|6335 unix-RPC|VBD.unplug R:9258f54578d6|xenops] watch: fired on /local/domain/0/error/device/vbd/51712/error [20100219 10:53:48.903|debug|culo|6418|Async.VM.hard_shutdown R:88d2095678f7|helpers] Ignoring exception: INTERNAL_ERROR: [ Xb.Noent ] while Vmops.destroy_domain: Destroying domid 14 guest session [20100219 10:53:52.048|debug|culo|6418|Async.VM.hard_shutdown R:88d2095678f7|xenops] xenstore-rm /local/domain/0/error/backend/tap/14 [20100219 10:53:52.048|debug|culo|6418|Async.VM.hard_shutdown R:88d2095678f7|xenops] xenstore-rm /local/domain/14/error/device/vbd/51744 [20100219 10:53:52.085|debug|culo|6418|Async.VM.hard_shutdown R:88d2095678f7|xenops] xenstore-rm /local/domain/0/error/backend/tap/14 [20100219 10:53:52.086|debug|culo|6418|Async.VM.hard_shutdown R:88d2095678f7|xenops] xenstore-rm /local/domain/14/error/device/vbd/51728 [20100219 10:53:52.122|debug|culo|6418|Async.VM.hard_shutdown R:88d2095678f7|xenops] xenstore-rm /local/domain/0/error/backend/tap/14 [20100219 10:53:52.122|debug|culo|6418|Async.VM.hard_shutdown R:88d2095678f7|xenops] xenstore-rm /local/domain/14/error/device/vbd/51712 [20100219 10:53:52.127|debug|culo|6418|Async.VM.hard_shutdown R:88d2095678f7|xenops] xenstore-rm /local/domain/0/error/backend/vbd/14 [20100219 10:53:52.128|debug|culo|6418|Async.VM.hard_shutdown R:88d2095678f7|xenops] xenstore-rm /local/domain/14/error/device/vbd/51760 [20100219 10:53:52.496|debug|culo|6418|Async.VM.hard_shutdown R:88d2095678f7|xenops] Device.Vif.hard_shutdown about to blow away backend and error paths [20100219 10:53:52.497|debug|culo|6418|Async.VM.hard_shutdown R:88d2095678f7|xenops] xenstore-rm /local/domain/0/error/backend/vif/14 [20100219 10:53:52.497|debug|culo|6418|Async.VM.hard_shutdown R:88d2095678f7|xenops] xenstore-rm /local/domain/14/error/device/vif/0 [20100219 10:53:53.385|debug|culo|6418|Async.VM.hard_shutdown R:88d2095678f7|xenops] Device.Vif.hard_shutdown about to blow away backend and error paths [20100219 10:53:53.386|debug|culo|6418|Async.VM.hard_shutdown R:88d2095678f7|xenops] xenstore-rm /local/domain/0/error/backend/vif/14 [20100219 10:53:53.386|debug|culo|6418|Async.VM.hard_shutdown R:88d2095678f7|xenops] xenstore-rm /local/domain/14/error/device/vif/1 [20100219 10:53:53.389| warn|culo|6418|Async.VM.hard_shutdown R:88d2095678f7|hotplug] Warning, deleting 'vif' entry from /xapi/14/hotplug/vif/0 [20100219 10:53:53.391| warn|culo|6418|Async.VM.hard_shutdown R:88d2095678f7|hotplug] Warning, deleting 'vif' entry from /xapi/14/hotplug/vif/1 [20100219 11:20:49.766|debug|culo|6484|Async.VM.clean_shutdown R:78d3c3e28cb6|helpers] Ignoring exception: INTERNAL_ERROR: [ Xb.Noent ] while Vmops.destroy_domain: Destroying domid 11 guest session [20100219 11:20:50.339|debug|culo|6484|Async.VM.clean_shutdown R:78d3c3e28cb6|xenops] xenstore-rm /local/domain/0/error/backend/tap/11 [20100219 11:20:50.339|debug|culo|6484|Async.VM.clean_shutdown R:78d3c3e28cb6|xenops] xenstore-rm /local/domain/11/error/device/vbd/832 [20100219 11:20:50.360|debug|culo|6484|Async.VM.clean_shutdown R:78d3c3e28cb6|xenops] xenstore-rm /local/domain/0/error/backend/tap/11 [20100219 11:20:50.360|debug|culo|6484|Async.VM.clean_shutdown R:78d3c3e28cb6|xenops] xenstore-rm /local/domain/11/error/device/vbd/768 [20100219 11:20:50.366|debug|culo|6484|Async.VM.clean_shutdown R:78d3c3e28cb6|xenops] xenstore-rm /local/domain/0/error/backend/vbd/11 [20100219 11:20:50.366|debug|culo|6484|Async.VM.clean_shutdown R:78d3c3e28cb6|xenops] xenstore-rm /local/domain/11/error/device/vbd/5696 [20100219 11:20:50.753|debug|culo|6484|Async.VM.clean_shutdown R:78d3c3e28cb6|xenops] Device.Vif.hard_shutdown about to blow away backend and error paths [20100219 11:20:50.754|debug|culo|6484|Async.VM.clean_shutdown R:78d3c3e28cb6|xenops] xenstore-rm /local/domain/0/error/backend/vif/11 [20100219 11:20:50.754|debug|culo|6484|Async.VM.clean_shutdown R:78d3c3e28cb6|xenops] xenstore-rm /local/domain/11/error/device/vif/1 [20100219 11:20:50.757| warn|culo|6484|Async.VM.clean_shutdown R:78d3c3e28cb6|hotplug] Warning, deleting 'vif' entry from /xapi/11/hotplug/vif/1 [20100219 11:28:13.803|debug|culo|6610 inet-RPC|Connection to VM console R:e9f8b76e8975|console] error: INTERNAL_ERROR: [ Unix.Unix_error(63, "connect", "") ]

    Read the article

  • edit row in gridview

    - by user576998
    Hi.I would like to help me with my code. I have 2 gridviews. In the first gridview the user can choose with a checkbox every row he wants. These rows are transfered in the second gridview. All these my code does them well.Now, I want to edit the quantity column in second gridview to change the value but i don't know what i must write in edit box. Here is my code: using System; using System.Data; using System.Data.SqlClient; using System.Configuration; using System.Web; using System.Web.Security; using System.Web.UI; using System.Web.UI.WebControls; using System.Web.UI.WebControls.WebParts; using System.Web.UI.HtmlControls; using System.Collections; public partial class ShowLand : System.Web.UI.Page { protected void Page_Load(object sender, EventArgs e) { if (!IsPostBack) { BindPrimaryGrid(); BindSecondaryGrid(); } } private void BindPrimaryGrid() { string constr = ConfigurationManager.ConnectionStrings["conString"].ConnectionString; string query = "select * from Land"; SqlConnection con = new SqlConnection(constr); SqlDataAdapter sda = new SqlDataAdapter(query, con); DataTable dt = new DataTable(); sda.Fill(dt); gridview2.DataSource = dt; gridview2.DataBind(); } private void GetData() { DataTable dt; if (ViewState["SelectedRecords1"] != null) dt = (DataTable)ViewState["SelectedRecords1"]; else dt = CreateDataTable(); CheckBox chkAll = (CheckBox)gridview2.HeaderRow .Cells[0].FindControl("chkAll"); for (int i = 0; i < gridview2.Rows.Count; i++) { if (chkAll.Checked) { dt = AddRow(gridview2.Rows[i], dt); } else { CheckBox chk = (CheckBox)gridview2.Rows[i] .Cells[0].FindControl("chk"); if (chk.Checked) { dt = AddRow(gridview2.Rows[i], dt); } else { dt = RemoveRow(gridview2.Rows[i], dt); } } } ViewState["SelectedRecords1"] = dt; } private void SetData() { CheckBox chkAll = (CheckBox)gridview2.HeaderRow.Cells[0].FindControl("chkAll"); chkAll.Checked = true; if (ViewState["SelectedRecords1"] != null) { DataTable dt = (DataTable)ViewState["SelectedRecords1"]; for (int i = 0; i < gridview2.Rows.Count; i++) { CheckBox chk = (CheckBox)gridview2.Rows[i].Cells[0].FindControl("chk"); if (chk != null) { DataRow[] dr = dt.Select("id = '" + gridview2.Rows[i].Cells[1].Text + "'"); chk.Checked = dr.Length > 0; if (!chk.Checked) { chkAll.Checked = false; } } } } } private DataTable CreateDataTable() { DataTable dt = new DataTable(); dt.Columns.Add("id"); dt.Columns.Add("name"); dt.Columns.Add("price"); dt.Columns.Add("quantity"); dt.Columns.Add("total"); dt.AcceptChanges(); return dt; } private DataTable AddRow(GridViewRow gvRow, DataTable dt) { DataRow[] dr = dt.Select("id = '" + gvRow.Cells[1].Text + "'"); if (dr.Length <= 0) { dt.Rows.Add(); dt.Rows[dt.Rows.Count - 1]["id"] = gvRow.Cells[1].Text; dt.Rows[dt.Rows.Count - 1]["name"] = gvRow.Cells[2].Text; dt.Rows[dt.Rows.Count - 1]["price"] = gvRow.Cells[3].Text; dt.Rows[dt.Rows.Count - 1]["quantity"] = gvRow.Cells[4].Text; dt.Rows[dt.Rows.Count - 1]["total"] = gvRow.Cells[5].Text; dt.AcceptChanges(); } return dt; } private DataTable RemoveRow(GridViewRow gvRow, DataTable dt) { DataRow[] dr = dt.Select("id = '" + gvRow.Cells[1].Text + "'"); if (dr.Length > 0) { dt.Rows.Remove(dr[0]); dt.AcceptChanges(); } return dt; } protected void CheckBox_CheckChanged(object sender, EventArgs e) { GetData(); SetData(); BindSecondaryGrid(); } private void BindSecondaryGrid() { DataTable dt = (DataTable)ViewState["SelectedRecords1"]; gridview3.DataSource = dt; gridview3.DataBind(); } } and the source code is <asp:GridView ID="gridview2" runat="server" AutoGenerateColumns="False" DataKeyNames="id" DataSourceID="SqlDataSource5"> <Columns> <asp:TemplateField> <HeaderTemplate> <asp:CheckBox ID="chkAll" runat="server" onclick = "checkAll(this);" AutoPostBack = "true" OnCheckedChanged = "CheckBox_CheckChanged"/> </HeaderTemplate> <ItemTemplate> <asp:CheckBox ID="chk" runat="server" onclick = "Check_Click(this)" AutoPostBack = "true" OnCheckedChanged = "CheckBox_CheckChanged" /> </ItemTemplate> </asp:TemplateField> <asp:BoundField DataField="id" HeaderText="id" InsertVisible="False" ReadOnly="True" SortExpression="id" /> <asp:BoundField DataField="name" HeaderText="name" SortExpression="name" /> <asp:BoundField DataField="price" HeaderText="price" SortExpression="price" /> <asp:BoundField DataField="quantity" HeaderText="quantity" SortExpression="quantity" /> <asp:BoundField DataField="total" HeaderText="total" SortExpression="total" /> </Columns> </asp:GridView> <asp:SqlDataSource ID="SqlDataSource5" runat="server" ConnectionString="<%$ ConnectionStrings:ConnectionString %>" SelectCommand="SELECT * FROM [Land]"></asp:SqlDataSource> <br /> </div> <div> <asp:GridView ID="gridview3" runat="server" AutoGenerateColumns = "False" DataKeyNames="id" EmptyDataText = "No Records Selected" > <Columns> <asp:BoundField DataField = "id" HeaderText = "id" /> <asp:BoundField DataField = "name" HeaderText = "name" ReadOnly="True" /> <asp:BoundField DataField = "price" HeaderText = "price" DataFormatString="{0:c}" ReadOnly="True" /> <asp:TemplateField HeaderText="quantity"> <EditItemTemplate> <asp:TextBox ID="TextBox1" runat="server" Text='<%# Bind("quantity")%>'</asp:TextBox> </EditItemTemplate> <ItemTemplate> <asp:Label ID="Label1" runat="server" Text='<%# Bind("quantity") %>'></asp:Label> </ItemTemplate> </asp:TemplateField> <asp:BoundField DataField = "total" HeaderText = "total" DataFormatString="{0:c}" ReadOnly="True" /> <asp:CommandField ShowEditButton="True" /> </Columns> </asp:GridView> <asp:Label ID="totalLabel" runat="server"></asp:Label> <br /> </div> </form> </body> </html>

    Read the article

  • why is port 500 in use and how can I free it? VPNC error

    - by kirill_igum
    i tried to use network manager to connect to my university's vpn; it didn't work. then i used a command line vpnc: > sudo vpnc [sudo] password for kirill: Enter IPSec gateway address: vpn.net.**.edu Enter IPSec ID for vpn.net.**.edu: ** Enter IPSec secret for **@vpn.net.**.edu: Enter username for vpn.net.**.edu: ** Enter password for **@vpn.net.**.edu: vpnc: Error binding to source port. Try '--local-port 0' Failed to bind to 0.0.0.0:500: Address already in use then i did this: sudo vpnc --local-port 0 with the same config and it all worked. i'd like to be able to use network manager gui to connect to vpn. I wanted to find out which program uses the port 500: > sudo netstat -a |grep 500 tcp 0 0 *:17500 *:* LISTEN udp 0 0 *:4500 *:* udp 0 0 *:17500 *:* unix 3 [ ] STREAM CONNECTED 63500 unix 3 [ ] STREAM CONNECTED 12500 @/tmp/.X11-unix/X0 there is nothing that uses 500 i'm using ubuntu 10.10 on thinkpad x201t

    Read the article

  • Samba: session setup failed: NT_STATUS_LOGON_FAILURE

    - by stivlo
    I tried to set up Samba with "unix password sync", but I still get logon failure. I am running Ubuntu Natty Narwhal. $ smbclient -L localhost Enter stivlo's password: session setup failed: NT_STATUS_LOGON_FAILURE Here is my /etc/samba/smb.conf [global] workgroup = obliquid server string = %h server (Samba, Ubuntu) dns proxy = no log file = /var/log/samba/log.%m max log size = 1000 syslog = 0 panic action = /usr/share/samba/panic-action %d security = user encrypt passwords = true passdb backend = tdbsam obey pam restrictions = yes unix password sync = yes passwd program = /usr/bin/passwd %u passwd chat = *Enter\snew\s*\spassword:* %n\n *Retype\snew\s*\spassword:* %n\n *password\supdated\ssuccessfully* . pam password change = yes map to guest = bad user [www] path = /var/www browsable = yes read only = no create mask = 0755 After modifying I restarted the servers: $ sudo restart smbd $ sudo restart nmbd However I still can't logon with my Unix username and password. Can anyone please help? Thank you in advance!

    Read the article

  • OS choice between: Debian, gNewSense, and OpenSolaris

    - by penyuan
    I am planning to migrate from Mac OS X and Windows to either a Unix or Linux distribution, i.e. I am a Linux/Unix beginner. Right now the following caught my interest: Debian: Well established with huge repository of 20000+ apps. gNewSence: "Totally free" version of Ubuntu, so it should be more beginner friendly? OpenSolaris: Also open-source, and built on "strong" Unix base. I do mainly basic tasks such as web browsing, office work, maintaining big photo collection, and a little bit of programming. Questions: How "free" are each of these distributions compared to each other, is this whole freedom thing a big deal? Will a binary labeled as for Ubuntu work on gNewSense? What are simple IDEs for Debian and gNewSense?

    Read the article

  • NGINX + PHP FPM connect() failed (110: Connection timed out) while connecting to upstream

    - by Leonard Teo
    We're running a fairly large site using nginx and PHP-FPM and we're getting a lot of errors as the site load is quite high. We're getting "connect() failed (110: Connection timed out) while connecting to upstream"...upstream: "fastcgi://127.0.0.1:9000" Here's my config file for PHP-FPM. PHP-FPM: [www] listen = 127.0.0.1:9000 listen.allowed_clients = 127.0.0.1 user = nginx group = nginx pm = dynamic pm.max_children = 100 pm.start_servers = 20 pm.min_spare_servers = 5 pm.max_spare_servers = 35 pm.max_requests = 100 slowlog = /var/log/php-fpm/www-slow.log php_admin_value[error_log] = /var/log/php-fpm/www-error.log php_admin_flag[log_errors] = on What's the recommended config/number of servers/children for a high traffic site? We tried using Unix Sockets instead of TCP and got no noticeable improvements. Right now the errors are: connect() to unix:/var/run/php-fcgi.sock failed (11: Resource temporarily unavailable) while connecting to upstream...upstream: "fastcgi://unix:/var/run/php-fcgi.sock:"... Thanks, Leonard

    Read the article

  • Email continuity services i.e. Messagelabs - Caveats, lessons learned, gotchas?

    - by molecule
    Hi all, I am in the process of reviewing some email continuity solutions such as the one offered by Messagelabs. Solutions such as this are not cheap, however, I believe they reduce complexity when it comes to administration and serves as a feasible DR type solution for emails as opposed to purchasing a new server for DR purposes. Have any of you had first hand experience using this service and what are your opinions and/or feedback? Thanks in advance.

    Read the article

  • LDAP for privilege control?

    - by neoice
    I've been wondering for a while if LDAP can be used to control user privileges. For example, if I have UNIX and web logins, is there an easy way to grant a user access to just or just UNIX (or even both?) My current attempt at solving this very problem was to create 'login' and 'nologin' groups, but this doesn't seem fine-grained enough to meet the ideas I have in my head. I'm also still in the situation where all UNIX users are web users, which isn't a problem so much as an indicator of the limitations. Does anyone have any input on this? Has this problem already been solved?

    Read the article

  • What's the difference between sudo su - postgres and sudo -u postgres?

    - by Craig Ringer
    PostgreSQL users peer authentication on unix sockets by default, where the unix user must be the same as the PostgreSQL user. So people frequently use su or sudo to become the postgres superuser. I often see people using constructs like: sudo su - postgres rather than sudo -u postgres -i and I'm wondering why. Similarly, I've seen: sudo su - postgres -c psql instead of sudo -u postgres psql Without the leading sudo the su versions would make some sense if you were on an old platform without sudo. But why on a less than prehisoric UNIX or Linux would you use sudo su ?

    Read the article

< Previous Page | 72 73 74 75 76 77 78 79 80 81 82 83  | Next Page >