  • How to create a static IP on Windows Server 2008 R2 so I can access the server remotely

    - by Aesir
    I have just purchased a HP Proliant N40L which I am intending to use as a NAS, learning tool and just in general something to mess around with. As a student via the Microsoft dreamspark program I can get a free copy of Windows Server 2008 R2 which I am using as the OS. So that I can remote to the box from outside of my local network and so that I can stream media from it to my PS3, I have read that I need to create a static IP for the server and use port forwarding to forward to this IP so I can remote in. Is this correct? I am not really sure how to do this and if I need to make these changes on my router configuration, on the OS or both. I am a novice when it comes to networking however most resources for Windows server 2008 R2 seem to assume a fair amount of experience already. I realise that using this particular OS may seem like overkill for what I currently wish to do with it (stream content to other devices and backup) but as I can get a copy for free it seems sensible. Edit: From reading answers posted I feel I should give more information. I have now tried to add a static IP address using my router configuration settings. I have used the getmac command to get the mac address of the server. My ISP is Virgin Media and I have gone to the LAN IP section and I have added an IP address to the DHCP Reservation Lease Info. I can now use remote desktop connection internally to remote to the server (so I am assuming assigning this IP has worked). How do I configure this on the OS as well? I am also unsure on how I would remote to this machine outside of my local network?

    Read the article

  • What should the memory configuration be?

    - by AngryHacker
    We have a server (ProLiant DL585 G1 by HP), which hosts Windows 2003 x64 R2 with SQL Server 2005 x64 and a host of other apps. It currently has 6GB of RAM. We are currently very memory constrained and it's clear that we need to get more memory. 8GB will probably do the trick, however, we are not sure as to what memory configuration will give us the biggest performance buck. Currently all 8 memory slots are filled (4 slots have 1GB chip, while the other 4 slots have 512MB chips). Should we throw the 512MB sticks away and just replace them all with 1GB sticks? If we decided to go with a higher memory configuration (e.g. 10GB or 12GB or 16GB), is it advisable to keep all the sticks of the same size or it does not matter? I was once told that interleaved memory requires (for better performance) that memory should be in multiples (e.g. 2 or 4 or 8 or 16, etc...). I am not even sure that the server has an interleaved configuration (and don't know how to find out), but is this true? Thanks.

    Read the article

  • HP/IBM alternative to Buffalo iSCSI TerraStation?

    - by Robin Day
    I'm looking at virtualising some of our infrastructure in order to allow for more resiliance and future expandability. We have successfully virtualised on single servers with Direct Attached Storage and are now looking for a more future proof solution using a high powered host (or two) and a SAN (or two). I'm thinking that the host machine will probably be an HP ProLiant DL360 G7 (all of our exisiting infrastructure is HP). Unfortunately, I am new to the world of SANs. From what I can see, the Buffalo Terrastation III is all I would need in order to setup an iSCSI SAN for VMWare to use. However, I'm a little reticent to go that way as it's a bit too "entry level" for my liking. In particular I would be very keen for more redundancy, power, networking, etc. I'm also very aware that you "get what you pay for". Therefore, can anyone reccommend equivalents from the big boys? HP/IBM? I have searched high and low on the HP site and seen many options but am struggling to work out if it is all the hardware I will need. Some options appear to need separate controllers from disk enclosures, etc.

    Read the article

  • What are the advantages of registered memory?

    - by odd parity
    I'm browsing for a few low-end servers for a startup and I'm a bit confused about the different memory types. The advantage of ECC is clear - single-bit error correction. When it comes to registered memory it seems more vague, especially in systems that support both registered and unbuffered memory. A Google search mostly finds copies of the Wikipedia article, which states that registered memory chips "...place less electrical load on the memory controller and allow single systems to remain stable with more memory modules than they would have otherwise". However I can't find any quantification of this. What I'm wondering about is: Is registered memory an improvement over unbuffered when it comes to soft error rate, or is it purely about the maximum number of modules supported? If yes, at what point (amount of modules or GB of memory) do these improvements start to become noticeable? For a specific example, the HP ProLiant DL 120 G6 server manual states that maximum supported memory configuration is 16 GB unbuffered (4x4GB) or 12 GB registered (6x2GB). In this case I'd rather have the extra 4GB of memory if the reliability difference is negligible.

    Read the article

  • Help Me Help You Fix That

    - by BuckWoody
    If you've been redirected here because you posted on a forum, or asked a question in an e-mail, the person wanted you to know how to get help quickly from a group of folks who are willing to do so - but whose time is valuable. You need to put a little effort into the question first to get others to assist. This is how to do that. It will only take you a moment to read... 1. State the problem succinctly in the title When an e-mail thread starts, or a forum post is the "head" of the conversation, you'll attract more helpers by using a descriptive headline than a vague one. This: "Driver for Epson Line Printer Not Installing on Operating System XYZ" Not this: "Can't print - PLEASE HELP" 2. Explain the Error Completely Make sure you include all pertinent information in the request. More information is better, there's almost no way to add too much data to the discussion. What you were doing, what happened, what you saw, the error message, visuals, screen shots, whatever you can include. This: "I'm getting error '5203 - Driver not compatible with Operating System since about 25 years ago' in a message box on the screen when I tried to run the SETUP.COM file from my older computer. It was a 1995 Compaq Proliant and worked correctly there.." Not this: "I get an error message in a box. It won't install." 3. Explain what you have done to research the problem If the first thing you do is ask a question without doing any research, you're lazy, and no one wants to help you. Using one of the many fine search engines you can most always find the answer to your problem. Sometimes you can't. Do yourself a favor - open a notepad app, and paste the URL's as you look them up. If you get your answer, don't save the note. If you don't get an answer, send the list along with the problem. It will show that you've tried, and also keep people from sending you links that you've already checked. This: "I read the fine manual, and it doesn't mention Operating System XYZ for some reason. Also, I checked the following links, but the instructions there didn't fix the problem: " Not this: <NULL> 4. Say "Please" and "Thank You" Remember, you're asking for help. No one owes you their valuable time. Ask politely, don't pester, endure the people who are rude to you, and when your question is answered, respond back to the thread or e-mail with a thank you to close it out. It helps others that have your same problem know that this is the correct answer. This: "I could really use some help here - if you have any pointers or things to try, I'd appreciate it." Not this: "I really need this done right now - why are there no responses?" This: "Thanks for those responses - that last one did the trick. Turns out I needed a new printer anyway, didn't realize they were so inexpensive now." Not this: <NULL> There are a lot of motivated people that will help you. Help them do that.

    Read the article

  • PXE-E32 TFTP Open Timeout While Attempting to PXE Boot from Windows Deployment Services

    - by bschafer
    I'm running Windows Deployment Services on Windows Server 2008 R2 on top of an ESX 4.0 box. This is the only function of this VM instance, although it had previously functioned as an AD Domain Controller. My DHCP server is running on our primary Domain Controller, which is also Server 2008 R2, but running on metal. Everything was working perfectly until we recently had our backup generator fail during a power outage, causing all of our servers and networking equipment to lose power for a period of time. When we brought all of our equipment back up, everything was working as expected except for WDS. Our network is split up into several different vlans. Now, depending on which vlan the client computer is on, it's behaving differently when attempting to PXE boot into WDS. Our servers are located on the 10.55.x.x vlan, which, due to the nature of it, has no DHCP server active in it. The first computer we plugged in happened to be in the 10.99.x.x vlan, which is supposed to be reserved for network management devices (i.e. switches), but we've been using it occasionally otherwise. That computer gave us PXE-E11 ARP Timeout errors. When we moved to a different computer on the 10.19.x.x vlan (for general purpose use), it finally gets an IP from DHCP, but it presents us with a very stumping PXE-E32 TFTP Open Timeout error. Before the power outage, it didn't matter which vlan a device was on; it would PXE boot and image just fine. I've made no changes to anything server-side. Everything is configured exactly the same way it was on my WDS and DHCP servers as before the power outage. I've tried several different computers, including different models. All of this, combined with the quirky behavior depending on the vlan, makes me think something went wrong in one or more of our switches, probably because of the power outage. Unfortunately, I'm no network guy, and I know very little about how to configure our switches properly. Is this an issue with switches, etc? If so, how can I fix it? Is there some magical option I'm not aware of? Does anybody out there have any hunches? I've pretty much exhausted my ideas. Our main switch is an HP Procurve 5406. We also have 3x HP Procurve 4208 switches. The ESX Server is an HP ProLiant DL380 G6. The WDS VM is currently using the VMXNET3 network adaptor, but we've also tried the E1000 adaptor.

    Read the article

  • Random servers in Citrix servers suddenly bluescreens (mostly 0x0000008e and 0x0000007e)

    - by Rasmus Rask
    I'm responsible for a Citrix Presentation Server 4.5 farm. Starting Friday 30. November, my servers started to crash randomly. So far we've experienced 80 crashes, so it's obviously becoming an increasingly big problem for us. I have 12+ years experience with IT, so I know the difference between 0 and 1, but I have a hard time cracking this. We've rolled back any recent changes I can think of for different groups of servers, but all groups still seem to crash. I don't have the skills to interpret the memory dumps to find the culprit. Has anyone encountered the same or a similar problem? - might be a generic Windows issue Other than executing "analyze -v" in WinDbg, how do I work my way through the memory dumps to see what actually triggered the BSOD? Any suggested steps in getting to the bottom of this? Any help is greatly appreciated. I can also provide links to kernel memory dumps or WinDbg output if necessary. Thanks! Problem description The majority of the STOP errors we encounter are: 0x0000008e KERNEL_MODE_EXCEPTION_NOT_HANDLED (50%) 0x0000007e SYSTEM_THREAD_EXCEPTION_NOT_HANDLED (26%) 0x00000050 PAGE_FAULT_IN_NONPAGED_AREA (21%) We also see a few 0x0000000a IRQL_NOT_LESS_OR_EQUAL (3%). For both 0x0000008e and 0x0000007e bug checks, the exception code is 0xc0000005 (Access Violation). When opening dump files in WinDbg, most details are exactly the same, for all the 0x0000008e and 0x0000007e bug checks respectively: 0x0000008e Exception address: 0x808bc9e3 Trap frame: [varies] FAILURE_BUCKET_ID: 0x8E_nt!HvpGetCellMapped+97 Probably Caused by (IMAGE_NAME): ntkrpamp.exe 0x0000007e Exception address: 0x808369b6 Exception record address: 0xf70d3be0 Context record address: 0xf70d38dc FAILURE_BUCKET_ID: 0x7E_nt!MmPurgeSection+14 Probably Caused by: memory_corruption About 30% of the crashes happens between 17:00 and 19:00, which leads me to believe this tend to happen more often during logoffs. But then again, only ~15% occurs between 15:00 and 17:00. Summary of farm Citrix Presentation Server 4.5 R06 on Windows Server 2003 R2 SP2 All high priority patches, at least as of October installed Virtualized using VMWare ESX/vSphere 4.1 on HP Proliant BL460c G6 blade servers About 53 Presentation Servers in production, divided into three silos - only one of which, the largest, is affected 2 vCPU's (5 GHz reserved), 8 GB RAM (all reserved) for each Presentation Server Plenty of free disk space Very few printer drivers - automated deletion of non-approved drivers every night ~1.000 peak concurrent users, which is reached at around 10:30 (on weekdays) Number of sessions steadily decline between 15:00 and 19:00 to ~230

    Read the article

  • All the Gear and No Idea: Suggestions for re-designing my home/office/entertainment network

    - by 5arx
    Help/ Advice/ Suggestions please: I have a load of kit that I love but which currently operate in disconnected, sometimes counter-productive way. Because I never really had a masterplan I just added these things one after another and connected them up in ad hoc ways. Since I bought my Macbook I've found I spend much less time on the MacPro that was until then my main machine. Perversely, as my job involves writing .Net software, I spend a lot of Mac time actually inside a Windows 7 VM. I stream media from the HP box to the PS3 and thus to the TV, but its not without its limitations/annoyances. We listen to each other's iTunes libraries but the music files are all over the place and it would be good to know they were all safely in one location (and fully backed up). I need to come up with a strategy that will allow me to use all the kit for work, play (recording live music, making tunes, iMovie work), pushing/streaming media to the TV and sharing files with my other half (she uses a Windows laptop and her iPod touch). Ideally I'd like to be able to work on any of the machines and have a shared homedrive that was visible to all machines so all my current files were synced up wherever i was. It would be great if I could access everything securely and quickly over the web. I'd also like to be able to set up a background backup process. The kit list thus far: Apple MacPro 8GB/3x250GB RAID0 + 1TB Apple MacBook Pro 13" 8GB/250GB - I spend a lot of my work time on a Windows 7 VM on this. Crappy Acer laptop (for children's use - iPlayer, watching movies/tv files) HP Proliant Server 4GB/80GB+160GB+300GB Sun Ultra 10 2 x 80GB (old, but in top-notch condition) PS3 160GB iPod Classic 2 x 8GB iPod Touch Observations: Part of the problem is our dual use of Windows and OS X - we can't go for a pure NT style roaming profile. Because the server is also used for hosting test/beta applications and a SQL Server db, it can't be dedicated to file serving. The two Macs really could do with sharing a roaming profile or similar. I'd love to be able to do something useful with the Ultra 10. My other half has been trying to throw it away for over five years now and regularly ask what function it serves in my study :-( I've got no shortage of 500GB external USB hard drives iMovie files are very large and ideally would be processed on a RAID system. Apple's TimeMachine isn't so great. If anyone could suggest all or part of a setup that would fulfil some of my requirements I'd be very grateful. I am willing to consider purchasing one or two more bits of kit (an Apple TV and a Squeezebox have been moted by friends) if they will help make efficiencies rather than add to the chaos and confusion. Thanks for looking.

    Read the article

  • DPM 2010 "Disk failed or disk not found"

    - by SysAdmin
    I have an HP Proliant ML110 G5 server with Windows server 2008R2 only dedicated for DPM 2010. This server has a limit in HD of 8TB which has already been met. I'm now stuck in this situation where my disk keeps failing "Disk failed or Disk not found" in the disk management. Only after I reboot the system the disk comes back up. Today I was running my monthly tape backup on a certain protection group and the disk failed again while the tape job was running (so the job wasn't completed). This is the description of the error in the alerts: "The disk Disk 1 - Hitachi HDS722020ALA330 SCSI Disk Device cannot be detected or has stopped responding. All subsequent protection activities that use this disk will fail until the disk is brought back online. (ID 3120)". My backup system is becoming useless! I don't think that is a hardware issue (please correct me if I'm wrong) since the HD works fine for a certain period of time which is becoming shorter and shorter. I basically have no more option to fix this problem. I tried to fix any error that was coming up in the event viewer with no luck (included one regarding the SQL2008 compatibility issue). The disk keeps failing! Now I'm only trying to recover/migrate the data from the disk that is having problem but my issue now is that I cannot add any drives to my server since I already got installed the maximum storage capacity 8TB. I thought about 2 simple options. Please tell me what you guys think about it; Unplug one of the 2 storage pool disks (disk0, that one without problem) from the machine and install a new one in order to migrate the data with the Migration tool for DPM. Remove the defective disk (disk1), put back the disk0 and run the synchronization/consistency check on all the groups to recreate replicas and recovery points. Run diskpart.exe and clean up the disk (loosing all data) and hoping that he will work after I sync all the protection groups. Both solutions are not elegant but I have no better options at the moment. Please I need some help. Thanks for your time Angelo

    Read the article

  • 2xAMD Opteron 6128 with libvirt, Physical CPU 13 doesn't exist

    - by yak
    I need help with libvirt(?) problem. Server specs: ProLiant DL165 G7 2x AMD Opteron(tm) Processor 6128 System: Debian GNU/Linux testing (wheezy) 3.2.0-3-amd64 libvirt 0.9.12-5 kvm 1:1.1.2+dfsg-2 $ grep processor /proc/cpuinfo | wc -l 16 $ virsh nodeinfo setlocale: No such file or directory CPU model: x86_64 CPU(s): 16 CPU frequency: 800 MHz CPU socket(s): 2 Core(s) per socket: 4 Thread(s) per core: 1 NUMA cell(s): 1 Memory size: 66114200 KiB $ virsh capabilities .. <topology> <cells num='4'> <cell id='0'> <cpus num='4'> <cpu id='0'/> <cpu id='1'/> <cpu id='2'/> <cpu id='3'/> </cpus> </cell> <cell id='1'> <cpus num='4'> <cpu id='4'/> <cpu id='5'/> <cpu id='6'/> <cpu id='7'/> </cpus> </cell> <cell id='2'> <cpus num='4'> <cpu id='12'/> <cpu id='13'/> <cpu id='14'/> <cpu id='15'/> </cpus> </cell> <cell id='3'> <cpus num='4'> <cpu id='8'/> <cpu id='9'/> <cpu id='10'/> <cpu id='11'/> </cpus> </cell> </cells> </topology> .. $ virsh vcpupin vm 0 13,12,11,10,9,8,7,6,5 error: Physical CPU 13 doesn't exist. error: cpulist: Invalid format. Question? Why my VM Guests use only first 8 CPUs and next 8 are idling? $ for host in virsh list | awk '{print $2}'; do virsh vcpuinfo $host; done | grep ^CPU: | sort | uniq CPU: 0 CPU: 1 CPU: 2 CPU: 3 CPU: 4 CPU: 5 CPU: 6 CPU: 7 Any ideas how to change it?

    Read the article

  • Can only bring up one of two interfaces

    - by mstaessen
    I'm having a bizarre issue with my HP Proliant DL 360 G4p server. It has two gigabit ethernet interfaces but I can bring up only one of them. This is starting to freak me out and that's why I turned here. I'm running the x64 ubuntu 11.10 server edition. lshw -c network shows that the second interface is disabled. I have no idea why ans how to enable it. $ sudo lshw -c network *-network:0 description: Ethernet interface product: NetXtreme BCM5704 Gigabit Ethernet vendor: Broadcom Corporation physical id: 2 bus info: pci@0000:02:02.0 logical name: eth0 version: 10 serial: 00:18:71:e3:6d:26 size: 100Mbit/s capacity: 1Gbit/s width: 64 bits clock: 66MHz capabilities: pcix pm vpd msi bus_master cap_list ethernet physical tp 10bt 10bt-fd 100bt 100bt-fd 1000bt 1000bt-fd autonegotiation configuration: autonegotiation=on broadcast=yes driver=tg3 driverversion=3.119 duplex=full firmware=5704-v3.27b, ASFIPMIc v2.36 ip=10.48.8.x latency=64 link=yes mingnt=64 multicast=yes port=twisted pair speed=100Mbit/s resources: irq:25 memory:fdf70000-fdf7ffff *-network:1 DISABLED description: Ethernet interface product: NetXtreme BCM5704 Gigabit Ethernet vendor: Broadcom Corporation physical id: 2.1 bus info: pci@0000:02:02.1 logical name: eth1 version: 10 serial: 00:18:71:e3:6d:25 capacity: 1Gbit/s width: 64 bits clock: 66MHz capabilities: pcix pm vpd msi bus_master cap_list ethernet physical tp 10bt 10bt-fd 100bt 100bt-fd 1000bt 1000bt-fd autonegotiation configuration: autonegotiation=on broadcast=yes driver=tg3 driverversion=3.119 firmware=5704-v3.27b latency=64 link=no mingnt=64 multicast=yes port=twisted pair resources: irq:26 memory:fdf60000-fdf6ffff If I try to ifup eth1, then I get $ sudo ifup eth1 Ignoring unknown interface eth1=eth1. I figured that's what happens when there is no eth1 listed in /etc/network/interfaces. But when I add the configuration for eth1, I still can't ifup. $ sudo ifup eth1 RTNETLINK answers: File exists Failed to bring up eth1. I've also tried ifconfig eth1 up but without any result. For clarity, I have added a masked version of /etc/network/interfaces. I don't think it is the cause of the problem though. $ cat /etc/network/interfaces # This file describes the network interfaces available on your system # and how to activate them. For more information, see interfaces(5). # The loopback network interface auto lo iface lo inet loopback # The primary network interface auto eth0 iface eth0 inet static address 10.48.8.x netmask 255.255.255.y network 10.48.8.z broadcast 10.48.8.t gateway 10.48.8.u auto eth1 iface eth1 inet static address 193.190.253.x netmask 255.255.255.y network 193.190.253.z broadcast 193.190.253.t gateway 193.190.253.u I really need some help fixing this. It's driving me crazy. Thanks.

    Read the article

  • Trouble with Samba Domain

    - by Arkevius
    I'm having a bit of trouble setting up this Samba domain correctly. I'm getting an Access Denied error when trying to add a Windows XP machine to the domain. I'll go through my scenario in detail, but for those of you wanting a TLDR summary it'll be at the bottom of this post. I have HP Proliant server with Ubuntu 12.04 LTS installed. For this particular environment, I need this server to act as a PDC, file server, and print server. I began by updating and upgrading the packages (of course). Then went to install samba, gnome-desktop, wine, and cpanm. Samba was, of course, for the PDC and file/print services. The GUI was needed because a certain software has to be installed on there that needs a GUI. Wine was needed because the software is Windows-native. And cpanm was for a perl script I have running. For Samba, I went into the smb.conf file and enabled domain logons, changed the workgroup/domain name, the logon script for a per-group basis (netlogon/%g), enabled the netlogon and profiles share, and setup a couple of custom shares for the file service. The printer was added later, and seems to be working just fine. I then restarted the services, and used the net groupmap command to ensure my unix groups were mapped correctly to the Windows groups. After this, I went to a Windows box, and was able to successfully join the domain without a problem. After some fidgeting with the software to get it running on the win boxes from the server (it's a records management system program, which stores it's database files on the server), I went to add another computer to the domain. But now it's saying Access Denied. Before when I had this trouble it was because I forgot to add the group "machines" so Samba could create machine accounts. Thinking this was the case, I manually created the machine account to test this theory. However, it would still give me an Access Denied error. That must mean it has something to do with permissions now, correct? I've been fighting with this server for the past two weeks. If it's not one thing that;s wrong, then it's something else completely different. This would be the third time I've actually reinstalled everything to start over. I'll post snippets of my system settings below. If anything else is needed, just say the word and I'll gather up the info. The unix group 'domadmin' is the Domain Admins group. Samba Administrator account administrator:x:1000:1000:Administrator,,,:/home/administrator:/bin/bash Adminstrator's groups administrator adm cdrom sudo dip plugdev lpadmin sambashare domadmin crimestar Samba's Configuration FIle (a snippet anyways) [global] workgroup = CITYPD server string = BPDServer dns proxy = no log file = /var/log/samba/log.%m max log size = 1000 syslog = 0 panic action = /usr/share/samba/panic-action %d security = user encrypt passwords = true passdb backend = tdbsam obey pam restrictions = yes unix password sync = yes passwd program = /usr/bin/passwd %u passwd chat = *Enter\snew\s*\spassword:* %n\n *Retype\snew\s*\spassword:* %n\n *password\supdated\ssuccessfully* . pam password change = yes map to guest = bad user domain logons = yes logon path = \\%L\srv\samba\profiles\%U logon script = logon.bat add machine script = /usr/sbin/useradd -g machines -c "%u machine account" -d /var/lib/samba -s /bin/false %u domain master = yes usershare allow guests = yes [netlogon] comment = Network Logon Service path = /srv/samba/netlogon/%g guest ok = yes read only = yes browseable = no [profiles] comment = All Printers browseable = no path = /var/spool/samba printable = yes guest ok = no read only = yes create mask = 0700 [print$] comment = Printer Drivers path = /var/lib/samba/printers browseable = yes read only = yes guest ok = no write list = root, @lpadmin [crimestar] comment = "Crimestar DB" path = /srv/crimestar/db valid users = @domadmin, @crimestar admin users = administrator writeable = yes guest ok = no browseable = no create mask = 0666 directory mask = 0777 [crimestarfiles] path = /home/administrator/.wine/drive_c/crimestar admin users = administrator browseable = yes ls -la on /srv/samba/profiles drwxrwxrwx 2 root machines 4096 Nov 21 15:27 . drwxr-xr-x 4 root root 4096 Nov 21 15:28 .. ls -la on /srv/samba/netlogon drwxr-xr-x 6 root root 4096 Nov 21 15:30 . drwxr-xr-x 4 root root 4096 Nov 21 15:28 .. drwxr-xr-x 2 root root 4096 Nov 21 15:30 crimestar drwxr-xr-x 2 root root 4096 Nov 21 18:13 domadmin drwxr-xr-x 3 root root 4096 Nov 21 15:30 guests drwxr-xr-x 2 root root 4096 Nov 21 15:29 users GrouMap list Domain Users (S-1-5-21-2978508755-2341913247-928297747-513) -> users Domain Admins (S-1-5-21-2978508755-2341913247-928297747-512) -> domadmin Domain Guests (S-1-5-21-2978508755-2341913247-928297747-514) -> nogroup TLDR I'm getting an Access Denied error message while trying to join a windows box to a samba domain, even after I successfully joined another computer without a problem. System settings / files are quoted above. Anyone have any ideas or suggestions?

    Read the article

  • AMD 24 core server memory bandwidth

    - by ntherning
    I need some help to determine whether the memory bandwidth I'm seeing under Linux on my server is normal or not. Here's the server spec: HP ProLiant DL165 G7 2x AMD Opteron 6164 HE 12-Core 40 GB RAM (10 x 4GB DDR1333) Debian 6.0 Using mbw on this server I get the following numbers: foo1:~# mbw -n 3 1024 Long uses 8 bytes. Allocating 2*134217728 elements = 2147483648 bytes of memory. Using 262144 bytes as blocks for memcpy block copy test. Getting down to business... Doing 3 runs per test. 0 Method: MEMCPY Elapsed: 0.58047 MiB: 1024.00000 Copy: 1764.082 MiB/s 1 Method: MEMCPY Elapsed: 0.58012 MiB: 1024.00000 Copy: 1765.152 MiB/s 2 Method: MEMCPY Elapsed: 0.58010 MiB: 1024.00000 Copy: 1765.201 MiB/s AVG Method: MEMCPY Elapsed: 0.58023 MiB: 1024.00000 Copy: 1764.811 MiB/s 0 Method: DUMB Elapsed: 0.36174 MiB: 1024.00000 Copy: 2830.778 MiB/s 1 Method: DUMB Elapsed: 0.35869 MiB: 1024.00000 Copy: 2854.817 MiB/s 2 Method: DUMB Elapsed: 0.35848 MiB: 1024.00000 Copy: 2856.481 MiB/s AVG Method: DUMB Elapsed: 0.35964 MiB: 1024.00000 Copy: 2847.310 MiB/s 0 Method: MCBLOCK Elapsed: 0.23546 MiB: 1024.00000 Copy: 4348.860 MiB/s 1 Method: MCBLOCK Elapsed: 0.23544 MiB: 1024.00000 Copy: 4349.230 MiB/s 2 Method: MCBLOCK Elapsed: 0.23544 MiB: 1024.00000 Copy: 4349.359 MiB/s AVG Method: MCBLOCK Elapsed: 0.23545 MiB: 1024.00000 Copy: 4349.149 MiB/s On one of my other servers (based on Intel Xeon E3-1270): foo2:~# mbw -n 3 1024 Long uses 8 bytes. Allocating 2*134217728 elements = 2147483648 bytes of memory. Using 262144 bytes as blocks for memcpy block copy test. Getting down to business... Doing 3 runs per test. 0 Method: MEMCPY Elapsed: 0.18960 MiB: 1024.00000 Copy: 5400.901 MiB/s 1 Method: MEMCPY Elapsed: 0.18922 MiB: 1024.00000 Copy: 5411.690 MiB/s 2 Method: MEMCPY Elapsed: 0.18944 MiB: 1024.00000 Copy: 5405.491 MiB/s AVG Method: MEMCPY Elapsed: 0.18942 MiB: 1024.00000 Copy: 5406.024 MiB/s 0 Method: DUMB Elapsed: 0.14838 MiB: 1024.00000 Copy: 6901.200 MiB/s 1 Method: DUMB Elapsed: 0.14818 MiB: 1024.00000 Copy: 6910.561 MiB/s 2 Method: DUMB Elapsed: 0.14820 MiB: 1024.00000 Copy: 6909.628 MiB/s AVG Method: DUMB Elapsed: 0.14825 MiB: 1024.00000 Copy: 6907.127 MiB/s 0 Method: MCBLOCK Elapsed: 0.04362 MiB: 1024.00000 Copy: 23477.623 MiB/s 1 Method: MCBLOCK Elapsed: 0.04262 MiB: 1024.00000 Copy: 24025.151 MiB/s 2 Method: MCBLOCK Elapsed: 0.04258 MiB: 1024.00000 Copy: 24048.849 MiB/s AVG Method: MCBLOCK Elapsed: 0.04294 MiB: 1024.00000 Copy: 23847.599 MiB/s For reference here's what I get on my Intel based laptop: laptop:~$ mbw -n 3 1024 Long uses 8 bytes. Allocating 2*134217728 elements = 2147483648 bytes of memory. Using 262144 bytes as blocks for memcpy block copy test. Getting down to business... Doing 3 runs per test. 0 Method: MEMCPY Elapsed: 0.40566 MiB: 1024.00000 Copy: 2524.269 MiB/s 1 Method: MEMCPY Elapsed: 0.38458 MiB: 1024.00000 Copy: 2662.638 MiB/s 2 Method: MEMCPY Elapsed: 0.38876 MiB: 1024.00000 Copy: 2634.043 MiB/s AVG Method: MEMCPY Elapsed: 0.39300 MiB: 1024.00000 Copy: 2605.600 MiB/s 0 Method: DUMB Elapsed: 0.30707 MiB: 1024.00000 Copy: 3334.745 MiB/s 1 Method: DUMB Elapsed: 0.30425 MiB: 1024.00000 Copy: 3365.653 MiB/s 2 Method: DUMB Elapsed: 0.30342 MiB: 1024.00000 Copy: 3374.849 MiB/s AVG Method: DUMB Elapsed: 0.30491 MiB: 1024.00000 Copy: 3358.328 MiB/s 0 Method: MCBLOCK Elapsed: 0.07875 MiB: 1024.00000 Copy: 13003.670 MiB/s 1 Method: MCBLOCK Elapsed: 0.08374 MiB: 1024.00000 Copy: 12228.034 MiB/s 2 Method: MCBLOCK Elapsed: 0.07635 MiB: 1024.00000 Copy: 13411.216 MiB/s AVG Method: MCBLOCK Elapsed: 0.07961 MiB: 1024.00000 Copy: 12862.006 MiB/s So according to mbw my laptop is 3 times faster than the server!!! Please help me explain this. I've also tried to mount a ram disk and use dd to benchmark it and I get similar differences so I don't think mbw is to blame. I've checked the BIOS settings and the memory seem to be running at full speed. According to the hosting company the modules are all OK. Could this have something to do with NUMA? It seems like Node Interleaving is disabled on this server. Will enabling it (thus turning off NUMA) make a difference? foo1:~# numactl --hardware available: 4 nodes (0-3) node 0 cpus: 0 1 2 3 4 5 node 0 size: 8190 MB node 0 free: 7898 MB node 1 cpus: 6 7 8 9 10 11 node 1 size: 12288 MB node 1 free: 12073 MB node 2 cpus: 18 19 20 21 22 23 node 2 size: 12288 MB node 2 free: 12034 MB node 3 cpus: 12 13 14 15 16 17 node 3 size: 8192 MB node 3 free: 8032 MB node distances: node 0 1 2 3 0: 10 20 20 20 1: 20 10 20 20 2: 20 20 10 20 3: 20 20 20 10

    Read the article

  • Cheapest way to connect 20-24 Sata II HDDs in a budget storage server?

    - by Joe Hopfgartner
    I need to assemble a high density storage server for as cheap as possible. It's been a while for me and the last systems I integrated didn't even have Sata yet... During my Research I of course stumbled about Nexsan SATA Beast, the BackBlaze storage Pods as well as some ridiculously overpriced HP Proliant or Dell storage solutions. Finally I choose Norco cases as the way to go. My eye is set on the RPC-4020, which is a 4U 19" Rackmount case with 20 Hot Swap 3.5" SATA/SAS Hdd trays (Backplanes included) and room for two 2.5" OS drives as well as a Slim Line CD-Rom. The backplanes connect with a single SATA port for each drive, so there are 20 internal SATA ports to to be connected. They also have redundant power ports which I think is quite nice. The cheapest price I have found is 290$ + 40$ shipping. In europe the cheapest unfortunately is 370€ (500$) + 40 € shipping... A nice alternative would be the RPC-4224 which has SFF-8087 Mini SAS connectors that bundle 4 SATA trays each. But it doesn't seem to be available in Europe (where i am) anywhere. So here comes my problem: What Mainboard/Controller to choose to connect them for as cheap as possible while still having nice data rates? I have to say that the server is intended as a Storage server with 1gps connectivity and the data transfer will be distributed very evenly across all drives. I also don't require any raid functionality. This is all done at application level, I just need JBOD. So for example if I go for the RPC 4020 Model I need to connect 20 Storage + 1 OS + 1 CDROM Sata ports. I searched a bit and stumbled across this very low priced controller: http://www.intel.com/products/server/raid-controllers/SASWT4I/SASWT4I-overview.htm They sell it for 115 € here and the specs say it can control up to 122 hard discs and has 4 Mini SAS connectors. So I would use 4 Mini SAS 36pin - 4 SATA 7pin cables to connect 4 SATA drives to each port and choose a Mainboard taht has 6 SATA on board (for example this one) and hurray, I can connect my 22 SATA devices for as low as about ~ 220 EUR (cpu, ram, psu, case not counted) Question: WOULD THAT WORK? And if not, why? 2nd Question: If I go for the 4220 or 4224 Model, I have internal Mini SAS connectors. Am I right in assuming that the backplane than acts as a "SAS Expander"? And can I just plug these SAS connectors into any SAS port I can find on my controller / mainboard or are there certain requirements? I know that SATA port multipliers only work with controllers that are ready for that. But isn't this expansion already implemented in the SAS standard? I am sorry that this is a very broad question, but I really spent the last week reading up and it seems to be not so clear! Especially all the controlling hardware specifications! 3rd Question: A lot of hardware specs feature "internal channels" and "internal connectors". The connecors are the physical numbers of places where I can plug a cable in. I got that. But are the "internal channels" always the maximum numbers of physical drives that can be used in the end? Or can I enhance this further by Expanders/Fanouts? 4th and last question: What do you think about the setup so far? Do you know any good alternatives? Maby I am completely going the wrong way and some DAS would be way better? Are there any comparable chassis available in europe? Please feel free to say whatever you think is relevant to the subject!

    Read the article

  • Oracle Expands Sun Blade Portfolio for Cloud and Highly Virtualized Environments

    - by Ferhat Hatay
    Oracle announced the expansion of Sun Blade Portfolio for cloud and highly virtualized environments that deliver powerful performance and simplified management as tightly integrated systems.  Along with the SPARC T3-1B blade server, Oracle VM blade cluster reference configuration and Oracle's optimized solution for Oracle WebLogic Suite, Oracle introduced the dual-node Sun Blade X6275 M2 server module with some impressive benchmark results.   Benchmarks on the Sun Blade X6275 M2 server module demonstrate the outstanding performance characteristics critical for running varied commercial applications used in cloud and highly virtualized environments.  These include best-in-class SPEC CPU2006 results with the Intel Xeon processor 5600 series, six Fluent world records and 1.8 times the price-performance of the IBM Power 755 running NAMD, a prominent bio-informatics workload.   Benchmarks for Sun Blade X6275 M2 server module  SPEC CPU2006  The Sun Blade X6275 M2 server module demonstrated best in class SPECint_rate2006 results for all published results using the Intel Xeon processor 5600 series, with a result of 679.  This result is 97% better than the HP BL460c G7 blade, 80% better than the IBM HS22V blade, and 79% better than the Dell M710 blade.  This result demonstrates the density advantage of the new Oracle's server module for space-constrained data centers.     Sun Blade X6275M2 (2 Nodes, Intel Xeon X5670 2.93GHz) - 679 SPECint_rate2006; HP ProLiant BL460c G7 (2.93 GHz, Intel Xeon X5670) - 347 SPECint_rate2006; IBM BladeCenter HS22V (Intel Xeon X5680)  - 377 SPECint_rate2006; Dell PowerEdge M710 (Intel Xeon X5680, 3.33 GHz) - 380 SPECint_rate2006.  SPEC, SPECint, SPECfp reg tm of Standard Performance Evaluation Corporation. Results from www.spec.org as of 11/24/2010 and this report.    For more specifics about these results, please go to see http://blogs.sun.com/BestPerf   Fluent The Sun Fire X6275 M2 server module produced world-record results on each of the six standard cases in the current "FLUENT 12" benchmark test suite at 8-, 12-, 24-, 32-, 64- and 96-core configurations. These results beat the most recent QLogic score with IBM DX 360 M series platforms and QLogic "Truescale" interconnects.  Results on sedan_4m test case on the Sun Blade X6275 M2 server module are 23% better than the HP C7000 system, and 20% better than the IBM DX 360 M2; Dell has not posted a result for this test case.  Results can be found at the FLUENT website.   ANSYS's FLUENT software solves fluid flow problems, and is based on a numerical technique called computational fluid dynamics (CFD), which is used in the automotive, aerospace, and consumer products industries. The FLUENT 12 benchmark test suite consists of seven models that are well suited for multi-node clustered environments and representative of modern engineering CFD clusters. Vendors benchmark their systems with the principal objective of providing comparative performance information for FLUENT software that, among other things, depends on compilers, optimization, interconnect, and the performance characteristics of the hardware.   FLUENT application performance is representative of other commercial applications that require memory and CPU resources to be available in a scalable cluster-ready format.  FLUENT benchmark has six conventional test cases (eddy_417k, turbo_500k, aircraft_2m, sedan_4m, truck_14m, truck_poly_14m) at various core counts.   All information on the FLUENT website (http://www.fluent.com) is Copyrighted1995-2010 by ANSYS Inc. Results as of November 24, 2010. For more specifics about these results, please go to see http://blogs.sun.com/BestPerf   NAMD Results on the Sun Blade X6275 M2 server module running NAMD (a parallel molecular dynamics code designed for high-performance simulation of large biomolecular systems) show up to a 1.8X better price/performance than IBM's Power 7-based system.  For space-constrained environments, the ultra-dense Sun Blade X6275 M2 server module provides a 1.7X better price/performance per rack unit than IBM's system.     IBM Power 755 4-way Cluster (16U). Total price for cluster: $324,212. See IBM United States Hardware Announcement 110-008, dated February 9, 2010, pp. 4, 21 and 39-46.  Sun Blade X6275 M2 8-Blade Cluster (10U). Total price for cluster:  $193,939. Price/performance and performance/RU comparisons based on f1ATPase molecule test results. Sun Blade X6275 M2 cluster: $3,568/step/sec, 5.435 step/sec/RU. IBM Power 755 cluster: $6,355/step/sec, 3.189 step/sec/U. See http://www-03.ibm.com/systems/power/hardware/reports/system_perf.html. See http://www.ks.uiuc.edu/Research/namd/performance.html for more information, results as of 11/24/10.   For more specifics about these results, please go to see http://blogs.sun.com/BestPerf   Reverse Time Migration The Reverse Time Migration is heavily used in geophysical imaging and modeling for Oil & Gas Exploration.  The Sun Blade X6275 M2 server module showed up to a 40% performance improvement over the previous generation server module with super-linear scalability to 16 nodes for the 9-Point Stencil used in this Reverse Time Migration computational kernel.  The balanced combination of Oracle's Sun Storage 7410 system with the Sun Blade X6275 M2 server module cluster showed linear scalability for the total application throughput, including the I/O and MPI communication, to produce a final 3-D seismic depth imaged cube for interpretation. The final image write time from the Sun Blade X6275 M2 server module nodes to Oracle's Sun Storage 7410 system achieved 10GbE line speed of 1.25 GBytes/second or better performance. Between subsequent runs, the effects of I/O buffer caching on the Sun Blade X6275 M2 server module nodes and write optimized caching on the Sun Storage 7410 system gave up to 1.8 GBytes/second effective write performance. The performance results and characterization of this Reverse Time Migration benchmark could serve as a useful measure for many other I/O intensive commercial applications. 3D VTI Reverse Time Migration Seismic Depth Imaging, see http://blogs.sun.com/BestPerf/entry/3d_vti_reverse_time_migration for more information, results as of 11/14/2010.                            

    Read the article

  • high load average, high wait, dmesg raid error messages (debian nfs server)

    - by John Stumbles
    Debian 6 on HP proliant (2 CPU) with raid (2*1.5T RAID1 + 2*2T RAID1 joined RAID0 to make 3.5T) running mainly nfs & imapd (plus samba for windows share & local www for previewing web pages); with local ubuntu desktop client mounting $HOME, laptops accessing imap & odd files (e.g. videos) via nfs/smb; boxes connected 100baseT or wifi via home router/switch uname -a Linux prole 2.6.32-5-686 #1 SMP Wed Jan 11 12:29:30 UTC 2012 i686 GNU/Linux Setup has been working for months but prone to intermittently going very slow (user experience on desktop mounting $HOME from server, or laptop playing videos) and now consistently so bad I've had to delve into it to try to find what's wrong(!) Server seems OK at low load e.g. (laptop) client (with $HOME on local disk) connecting to server's imapd and nfs mounting RAID to access 1 file: top shows load ~ 0.1 or less, 0 wait but when (desktop) client mounts $HOME and starts user KDE session (all accessing server) then top shows e.g. top - 13:41:17 up 3:43, 3 users, load average: 9.29, 9.55, 8.27 Tasks: 158 total, 1 running, 157 sleeping, 0 stopped, 0 zombie Cpu(s): 0.4%us, 0.4%sy, 0.0%ni, 49.0%id, 49.7%wa, 0.0%hi, 0.5%si, 0.0%st Mem: 903856k total, 851784k used, 52072k free, 171152k buffers Swap: 0k total, 0k used, 0k free, 476896k cached PID USER PR NI VIRT RES SHR S %CPU %MEM TIME+ COMMAND 3935 root 20 0 2456 1088 784 R 2 0.1 0:00.02 top 1 root 20 0 2028 680 584 S 0 0.1 0:01.14 init 2 root 20 0 0 0 0 S 0 0.0 0:00.00 kthreadd 3 root RT 0 0 0 0 S 0 0.0 0:00.00 migration/0 4 root 20 0 0 0 0 S 0 0.0 0:00.12 ksoftirqd/0 5 root RT 0 0 0 0 S 0 0.0 0:00.00 watchdog/0 6 root RT 0 0 0 0 S 0 0.0 0:00.00 migration/1 7 root 20 0 0 0 0 S 0 0.0 0:00.16 ksoftirqd/1 8 root RT 0 0 0 0 S 0 0.0 0:00.00 watchdog/1 9 root 20 0 0 0 0 S 0 0.0 0:00.42 events/0 10 root 20 0 0 0 0 S 0 0.0 0:02.26 events/1 11 root 20 0 0 0 0 S 0 0.0 0:00.00 cpuset 12 root 20 0 0 0 0 S 0 0.0 0:00.00 khelper 13 root 20 0 0 0 0 S 0 0.0 0:00.00 netns 14 root 20 0 0 0 0 S 0 0.0 0:00.00 async/mgr 15 root 20 0 0 0 0 S 0 0.0 0:00.00 pm 16 root 20 0 0 0 0 S 0 0.0 0:00.02 sync_supers 17 root 20 0 0 0 0 S 0 0.0 0:00.02 bdi-default 18 root 20 0 0 0 0 S 0 0.0 0:00.00 kintegrityd/0 19 root 20 0 0 0 0 S 0 0.0 0:00.00 kintegrityd/1 20 root 20 0 0 0 0 S 0 0.0 0:00.02 kblockd/0 21 root 20 0 0 0 0 S 0 0.0 0:00.08 kblockd/1 22 root 20 0 0 0 0 S 0 0.0 0:00.00 kacpid 23 root 20 0 0 0 0 S 0 0.0 0:00.00 kacpi_notify 24 root 20 0 0 0 0 S 0 0.0 0:00.00 kacpi_hotplug 25 root 20 0 0 0 0 S 0 0.0 0:00.00 kseriod 28 root 20 0 0 0 0 S 0 0.0 0:04.19 kondemand/0 29 root 20 0 0 0 0 S 0 0.0 0:02.93 kondemand/1 30 root 20 0 0 0 0 S 0 0.0 0:00.00 khungtaskd 31 root 20 0 0 0 0 S 0 0.0 0:00.18 kswapd0 32 root 25 5 0 0 0 S 0 0.0 0:00.00 ksmd 33 root 20 0 0 0 0 S 0 0.0 0:00.00 aio/0 34 root 20 0 0 0 0 S 0 0.0 0:00.00 aio/1 35 root 20 0 0 0 0 S 0 0.0 0:00.00 crypto/0 36 root 20 0 0 0 0 S 0 0.0 0:00.00 crypto/1 203 root 20 0 0 0 0 S 0 0.0 0:00.00 ksuspend_usbd 204 root 20 0 0 0 0 S 0 0.0 0:00.00 khubd 205 root 20 0 0 0 0 S 0 0.0 0:00.00 ata/0 206 root 20 0 0 0 0 S 0 0.0 0:00.00 ata/1 207 root 20 0 0 0 0 S 0 0.0 0:00.14 ata_aux 208 root 20 0 0 0 0 S 0 0.0 0:00.01 scsi_eh_0 dmesg suggests there's a disk problem: .............. (previous episode) [13276.966004] raid1:md0: read error corrected (8 sectors at 489900360 on sdc7) [13276.966043] raid1: sdb7: redirecting sector 489898312 to another mirror [13279.569186] ata4.00: exception Emask 0x0 SAct 0x1 SErr 0x0 action 0x0 [13279.569211] ata4.00: irq_stat 0x40000008 [13279.569230] ata4.00: failed command: READ FPDMA QUEUED [13279.569257] ata4.00: cmd 60/08:00:00:6a:05/00:00:23:00:00/40 tag 0 ncq 4096 in [13279.569262] res 41/40:00:05:6a:05/00:00:23:00:00/40 Emask 0x409 (media error) <F> [13279.569306] ata4.00: status: { DRDY ERR } [13279.569321] ata4.00: error: { UNC } [13279.575362] ata4.00: configured for UDMA/133 [13279.575388] ata4: EH complete [13283.169224] ata4.00: exception Emask 0x0 SAct 0x1 SErr 0x0 action 0x0 [13283.169246] ata4.00: irq_stat 0x40000008 [13283.169263] ata4.00: failed command: READ FPDMA QUEUED [13283.169289] ata4.00: cmd 60/08:00:00:6a:05/00:00:23:00:00/40 tag 0 ncq 4096 in [13283.169294] res 41/40:00:07:6a:05/00:00:23:00:00/40 Emask 0x409 (media error) <F> [13283.169331] ata4.00: status: { DRDY ERR } [13283.169345] ata4.00: error: { UNC } [13283.176071] ata4.00: configured for UDMA/133 [13283.176104] ata4: EH complete [13286.224814] ata4.00: exception Emask 0x0 SAct 0x1 SErr 0x0 action 0x0 [13286.224837] ata4.00: irq_stat 0x40000008 [13286.224853] ata4.00: failed command: READ FPDMA QUEUED [13286.224879] ata4.00: cmd 60/08:00:00:6a:05/00:00:23:00:00/40 tag 0 ncq 4096 in [13286.224884] res 41/40:00:06:6a:05/00:00:23:00:00/40 Emask 0x409 (media error) <F> [13286.224922] ata4.00: status: { DRDY ERR } [13286.224935] ata4.00: error: { UNC } [13286.231277] ata4.00: configured for UDMA/133 [13286.231303] ata4: EH complete [13288.802623] ata4.00: exception Emask 0x0 SAct 0x1 SErr 0x0 action 0x0 [13288.802646] ata4.00: irq_stat 0x40000008 [13288.802662] ata4.00: failed command: READ FPDMA QUEUED [13288.802688] ata4.00: cmd 60/08:00:00:6a:05/00:00:23:00:00/40 tag 0 ncq 4096 in [13288.802693] res 41/40:00:05:6a:05/00:00:23:00:00/40 Emask 0x409 (media error) <F> [13288.802731] ata4.00: status: { DRDY ERR } [13288.802745] ata4.00: error: { UNC } [13288.808901] ata4.00: configured for UDMA/133 [13288.808927] ata4: EH complete [13291.380430] ata4.00: exception Emask 0x0 SAct 0x1 SErr 0x0 action 0x0 [13291.380453] ata4.00: irq_stat 0x40000008 [13291.380470] ata4.00: failed command: READ FPDMA QUEUED [13291.380496] ata4.00: cmd 60/08:00:00:6a:05/00:00:23:00:00/40 tag 0 ncq 4096 in [13291.380501] res 41/40:00:05:6a:05/00:00:23:00:00/40 Emask 0x409 (media error) <F> [13291.380577] ata4.00: status: { DRDY ERR } [13291.380594] ata4.00: error: { UNC } [13291.386517] ata4.00: configured for UDMA/133 [13291.386543] ata4: EH complete [13294.347147] ata4.00: exception Emask 0x0 SAct 0x1 SErr 0x0 action 0x0 [13294.347169] ata4.00: irq_stat 0x40000008 [13294.347186] ata4.00: failed command: READ FPDMA QUEUED [13294.347211] ata4.00: cmd 60/08:00:00:6a:05/00:00:23:00:00/40 tag 0 ncq 4096 in [13294.347217] res 41/40:00:06:6a:05/00:00:23:00:00/40 Emask 0x409 (media error) <F> [13294.347254] ata4.00: status: { DRDY ERR } [13294.347268] ata4.00: error: { UNC } [13294.353556] ata4.00: configured for UDMA/133 [13294.353583] sd 3:0:0:0: [sdc] Unhandled sense code [13294.353590] sd 3:0:0:0: [sdc] Result: hostbyte=DID_OK driverbyte=DRIVER_SENSE [13294.353599] sd 3:0:0:0: [sdc] Sense Key : Medium Error [current] [descriptor] [13294.353610] Descriptor sense data with sense descriptors (in hex): [13294.353616] 72 03 11 04 00 00 00 0c 00 0a 80 00 00 00 00 00 [13294.353635] 23 05 6a 06 [13294.353644] sd 3:0:0:0: [sdc] Add. Sense: Unrecovered read error - auto reallocate failed [13294.353657] sd 3:0:0:0: [sdc] CDB: Read(10): 28 00 23 05 6a 00 00 00 08 00 [13294.353675] end_request: I/O error, dev sdc, sector 587557382 [13294.353726] ata4: EH complete [13294.366953] raid1:md0: read error corrected (8 sectors at 489900544 on sdc7) [13294.366992] raid1: sdc7: redirecting sector 489898496 to another mirror and they're happening quite frequently, which I guess is liable to account for the performance problem(?) # dmesg | grep mirror [12433.561822] raid1: sdc7: redirecting sector 489900464 to another mirror [12449.428933] raid1: sdb7: redirecting sector 489900504 to another mirror [12464.807016] raid1: sdb7: redirecting sector 489900512 to another mirror [12480.196222] raid1: sdb7: redirecting sector 489900520 to another mirror [12495.585413] raid1: sdb7: redirecting sector 489900528 to another mirror [12510.974424] raid1: sdb7: redirecting sector 489900536 to another mirror [12526.374933] raid1: sdb7: redirecting sector 489900544 to another mirror [12542.619938] raid1: sdc7: redirecting sector 489900608 to another mirror [12559.431328] raid1: sdc7: redirecting sector 489900616 to another mirror [12576.553866] raid1: sdc7: redirecting sector 489900624 to another mirror [12592.065265] raid1: sdc7: redirecting sector 489900632 to another mirror [12607.621121] raid1: sdc7: redirecting sector 489900640 to another mirror [12623.165856] raid1: sdc7: redirecting sector 489900648 to another mirror [12638.699474] raid1: sdc7: redirecting sector 489900656 to another mirror [12655.610881] raid1: sdc7: redirecting sector 489900664 to another mirror [12672.255617] raid1: sdc7: redirecting sector 489900672 to another mirror [12672.288746] raid1: sdc7: redirecting sector 489900680 to another mirror [12672.332376] raid1: sdc7: redirecting sector 489900688 to another mirror [12672.362935] raid1: sdc7: redirecting sector 489900696 to another mirror [12674.201177] raid1: sdc7: redirecting sector 489900704 to another mirror [12698.045050] raid1: sdc7: redirecting sector 489900712 to another mirror [12698.089309] raid1: sdc7: redirecting sector 489900720 to another mirror [12698.111999] raid1: sdc7: redirecting sector 489900728 to another mirror [12698.134006] raid1: sdc7: redirecting sector 489900736 to another mirror [12719.034376] raid1: sdc7: redirecting sector 489900744 to another mirror [12734.545775] raid1: sdc7: redirecting sector 489900752 to another mirror [12734.590014] raid1: sdc7: redirecting sector 489900760 to another mirror [12734.624050] raid1: sdc7: redirecting sector 489900768 to another mirror [12734.647308] raid1: sdc7: redirecting sector 489900776 to another mirror [12734.664657] raid1: sdc7: redirecting sector 489900784 to another mirror [12734.710642] raid1: sdc7: redirecting sector 489900792 to another mirror [12734.721919] raid1: sdc7: redirecting sector 489900800 to another mirror [12734.744732] raid1: sdc7: redirecting sector 489900808 to another mirror [12734.779330] raid1: sdc7: redirecting sector 489900816 to another mirror [12782.604564] raid1: sdb7: redirecting sector 1242934216 to another mirror [12798.264153] raid1: sdc7: redirecting sector 1242935080 to another mirror [13245.832193] raid1: sdb7: redirecting sector 489898296 to another mirror [13261.376929] raid1: sdb7: redirecting sector 489898304 to another mirror [13276.966043] raid1: sdb7: redirecting sector 489898312 to another mirror [13294.366992] raid1: sdc7: redirecting sector 489898496 to another mirror although the arrays are still running on all disks - they haven't given up on any yet: # cat /proc/mdstat Personalities : [raid1] [raid0] md10 : active raid0 md0[0] md1[1] 3368770048 blocks super 1.2 512k chunks md1 : active raid1 sde2[2] sdd2[1] 1464087824 blocks super 1.2 [2/2] [UU] md0 : active raid1 sdb7[0] sdc7[2] 1904684920 blocks super 1.2 [2/2] [UU] unused devices: <none> So I think I have some idea what the problem is but I am not a linux sysadmin expert by the remotest stretch of the imagination and would really appreciate some clue checking here with my diagnosis and what do I need to do: obviously I need to source another drive for sdc. (I'm guessing I could buy a larger drive if the price is right: I'm thinking that one day I'll need to grow the size of the array and that would be one less drive to replace with a larger one) then use mdadm to fail out the existing sdc, remove it and fit the new drive fdisk the new drive with the same size partition for the array as the old one had use mdadm to add the new drive into the array that sound OK?

    Read the article