  • Can't Remove Logical Drive/Array from HP P400

    - by Myles
    This is my first post here. Thank you in advance for any assistance with this matter. I'm trying to remove a logical drive (logical drive 2) and an array (array "B") from my Smart Array P400. The host is a DL580 G5 running 64-bit Red Hat Enterprise Linux Server release 5.7 (Tikanga). I am unable to remove the array using either hpacucli or cpqacuxe. I believe it is because of "OS Status: LOCKED". The file system that lives on this array has been unmounted. I do not want to reboot the host. Is there some way to "release" this logical drive so I can remove the array? Note that I do not need to preserve the data on logical drive 2. I intend to physically remove the drives from the machine and replace them with larger drives. I'm using the cciss kernel module that ships with Red Hat 5.7. Here is some information pertaining to the host and the P400 configuration: [root@gort ~]# cat /etc/redhat-release Red Hat Enterprise Linux Server release 5.7 (Tikanga) [root@gort ~]# uname -a Linux gort 2.6.18-274.el5 #1 SMP Fri Jul 8 17:36:59 EDT 2011 x86_64 x86_64 x86_64 GNU/Linux [root@gort ~]# rpm -qa | egrep '^(hp|cpq)' cpqacuxe-9.30-15.0 hp-health-9.25-1551.7.rhel5 hpsmh-7.1.2-3 hpdiags-9.3.0-466 hponcfg-3.1.0-0 hp-snmp-agents-9.25-2384.8.rhel5 hpacucli-9.30-15.0 [root@gort ~]# hpacucli HP Array Configuration Utility CLI 9.30.15.0 Detecting Controllers...Done. Type "help" for a list of supported commands. Type "exit" to close the console. => ctrl all show config detail Smart Array P400 in Slot 0 (Embedded) Bus Interface: PCI Slot: 0 Cache Serial Number: PA82C0J9SVW34U RAID 6 (ADG) Status: Enabled Controller Status: OK Hardware Revision: D Firmware Version: 7.22 Rebuild Priority: Medium Expand Priority: Medium Surface Scan Delay: 15 secs Surface Scan Mode: Idle Wait for Cache Room: Disabled Surface Analysis Inconsistency Notification: Disabled Post Prompt Timeout: 0 secs Cache Board Present: True Cache Status: OK Cache Ratio: 25% Read / 75% Write Drive Write Cache: Disabled Total Cache Size: 256 MB Total Cache Memory Available: 208 MB No-Battery Write Cache: Disabled Cache Backup Power Source: Batteries Battery/Capacitor Count: 1 Battery/Capacitor Status: OK SATA NCQ Supported: True Logical Drive: 1 Size: 136.7 GB Fault Tolerance: RAID 1 Heads: 255 Sectors Per Track: 32 Cylinders: 35132 Strip Size: 128 KB Full Stripe Size: 128 KB Status: OK Caching: Enabled Unique Identifier: 600508B100184A395356573334550002 Disk Name: /dev/cciss/c0d0 Mount Points: /boot 101 MB, /tmp 7.8 GB, /usr 3.9 GB, /usr/local 2.0 GB, /var 3.9 GB, / 2.0 GB, /local 113.2 GB OS Status: LOCKED Logical Drive Label: A0027AA78DEE Mirror Group 0: physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 146 GB, OK) Mirror Group 1: physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 146 GB, OK) Drive Type: Data Array: A Interface Type: SAS Unused Space: 0 MB Status: OK Array Type: Data physicaldrive 1I:1:1 Port: 1I Box: 1 Bay: 1 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 146 GB Rotational Speed: 10000 Firmware Revision: HPDE Serial Number: 3NM57RF40000983878FX Model: HP DG146BB976 Current Temperature (C): 29 Maximum Temperature (C): 35 PHY Count: 2 PHY Transfer Rate: Unknown, Unknown physicaldrive 1I:1:2 Port: 1I Box: 1 Bay: 2 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 146 GB Rotational Speed: 10000 Firmware Revision: HPDE Serial Number: 3NM55VQC000098388524 Model: HP DG146BB976 Current Temperature (C): 29 Maximum Temperature (C): 36 PHY Count: 2 PHY Transfer Rate: Unknown, Unknown Logical Drive: 2 Size: 546.8 GB Fault Tolerance: RAID 5 Heads: 255 Sectors Per Track: 32 Cylinders: 65535 Strip Size: 64 KB Full Stripe Size: 256 KB Status: OK Caching: Enabled Parity Initialization Status: Initialization Completed Unique Identifier: 600508B100184A395356573334550003 Disk Name: /dev/cciss/c0d1 Mount Points: None OS Status: LOCKED Logical Drive Label: A5C9C6F81504 Drive Type: Data Array: B Interface Type: SAS Unused Space: 0 MB Status: OK Array Type: Data physicaldrive 1I:1:3 Port: 1I Box: 1 Bay: 3 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 146 GB Rotational Speed: 10000 Firmware Revision: HPDE Serial Number: 3NM2H5PE00009802NK19 Model: HP DG146ABAB4 Current Temperature (C): 30 Maximum Temperature (C): 37 PHY Count: 1 PHY Transfer Rate: Unknown physicaldrive 1I:1:4 Port: 1I Box: 1 Bay: 4 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 146 GB Rotational Speed: 10000 Firmware Revision: HPDE Serial Number: 3NM28YY400009750MKPJ Model: HP DG146ABAB4 Current Temperature (C): 31 Maximum Temperature (C): 36 PHY Count: 1 PHY Transfer Rate: 3.0Gbps physicaldrive 2I:1:5 Port: 2I Box: 1 Bay: 5 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 146 GB Rotational Speed: 10000 Firmware Revision: HPDE Serial Number: 3NM2FGYV00009802N3GN Model: HP DG146ABAB4 Current Temperature (C): 30 Maximum Temperature (C): 38 PHY Count: 1 PHY Transfer Rate: Unknown physicaldrive 2I:1:6 Port: 2I Box: 1 Bay: 6 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 146 GB Rotational Speed: 10000 Firmware Revision: HPDE Serial Number: 3NM8AFAK00009920MMV1 Model: HP DG146BB976 Current Temperature (C): 31 Maximum Temperature (C): 41 PHY Count: 2 PHY Transfer Rate: Unknown, Unknown physicaldrive 2I:1:7 Port: 2I Box: 1 Bay: 7 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 146 GB Rotational Speed: 10000 Firmware Revision: HPDE Serial Number: 3NM2FJQD00009801MSHQ Model: HP DG146ABAB4 Current Temperature (C): 29 Maximum Temperature (C): 39 PHY Count: 1 PHY Transfer Rate: Unknown

    Read the article

  • HP ML115 with P400 Smart Array Controller

    - by John
    Hi, I have a HP ML115 server I have installed a HP P400 Smart Array Controller card, I also have 4 x 1TB Samsung Hard drives. I'm unable to get the the controller to detect the hard drives, I have changed the drives to SATA 1.5G without luck, I have also tried connecting a single 80GB Maxtor drive without luck The controller shows up just after boot and tries to initialize, The controller does not show up in the POST prompt, although I can see the controller when booting off a ACU CD THe controller firmware is a little old v4.12 but I have no way to update it. Any ideas on how I can get this going?

    Read the article

  • ZFS SAS/SATA controller recommendations

    - by ewwhite
    I've been working with OpenSolaris and ZFS for 6 months, primarily on a Sun Fire x4540 and standard Dell and HP hardware. One downside to standard Perc and HP Smart Array controllers is that they do not have a true "passthrough" JBOD mode to present individual disks to ZFS. One can configure multiple RAID 0 arrays and get them working in ZFS, but it impacts hotswap capabilities (thus requiring a reboot upon disk failure/replacement). I'm curious as to what SAS/SATA controllers are recommended for home-brewed ZFS storage solutions. In addition, what effect does battery-backed write cache (BBWC) have in ZFS storage?

    Read the article

  • HP to Cisco spanning tree root flapping

    - by Tim Brigham
    Per a recent question I recently configured both my HP (2x 2900) and Cisco (1x 3750) hardware to use MSTP for interoperability. I thought this was functional until I applied the change to the third device (HP switch 1 below) at which time the spanning tree root started flapping causing performance issues (5% packet loss) between my two HP switches. I'm not sure why. HP Switch 1 A4 connected to Cisco 1/0/1. HP Switch 2 B2 connected to Cisco 2/0/1. HP Switch 1 A2 connected to HP Switch 2 A1. I'd prefer the Cisco stack to act as the root. EDIT: There is one specific line - 'spanning-tree 1 path-cost 500000' in the HP switch 2 that I didn't add and was preexisting. I'm not sure if it could have the kind of impact that I'm describing. I'm more a security and monitoring guy then networking. EDIT 2: I'm starting to believe the problem lies in the fact that the value for my MST 0 instance on the Cisco is still at the default 32768. I worked up a diagram: This is based on every show command I could find for STP. I'll make this change after hours and see if it helps. Cisco 3750 Config: version 12.2 spanning-tree mode mst spanning-tree extend system-id spanning-tree mst configuration name mstp revision 1 instance 1 vlan 1, 40, 70, 100, 250 spanning-tree mst 1 priority 0 vlan internal allocation policy ascending interface TenGigabitEthernet1/1/1 switchport trunk encapsulation dot1q switchport mode trunk ! interface TenGigabitEthernet2/1/1 switchport trunk encapsulation dot1q switchport mode trunk ! interface Vlan1 no ip address ! interface Vlan100 ip address 192.168.100.253 255.255.255.0 ! Cisco 3750 show spanning tree: show spanning-tree MST0 Spanning tree enabled protocol mstp Root ID Priority 32768 Address 0004.ea84.5f80 Cost 200000 Port 53 (TenGigabitEthernet1/1/1) Hello Time 2 sec Max Age 20 sec Forward Delay 15 sec Bridge ID Priority 32768 (priority 32768 sys-id-ext 0) Address a44c.11a6.7c80 Hello Time 2 sec Max Age 20 sec Forward Delay 15 sec Interface Role Sts Cost Prio.Nbr Type ------------------- ---- --- --------- -------- -------------------------------- Te1/1/1 Root FWD 2000 128.53 P2p MST1 Spanning tree enabled protocol mstp Root ID Priority 1 Address a44c.11a6.7c80 This bridge is the root Hello Time 2 sec Max Age 20 sec Forward Delay 15 sec Bridge ID Priority 1 (priority 0 sys-id-ext 1) Address a44c.11a6.7c80 Hello Time 2 sec Max Age 20 sec Forward Delay 15 sec Interface Role Sts Cost Prio.Nbr Type ------------------- ---- --- --------- -------- -------------------------------- Te1/1/1 Desg FWD 2000 128.53 P2p Cisco 3750 show logging: %LINEPROTO-5-UPDOWN: Line protocol on Interface Vlan1, changed state to down %LINEPROTO-5-UPDOWN: Line protocol on Interface Vlan100, changed state to down %LINEPROTO-5-UPDOWN: Line protocol on Interface Vlan1, changed state to up %LINEPROTO-5-UPDOWN: Line protocol on Interface Vlan100, changed state to up %LINEPROTO-5-UPDOWN: Line protocol on Interface Vlan1, changed state to down %LINEPROTO-5-UPDOWN: Line protocol on Interface Vlan1, changed state to up HP Switch 1: ; J9049A Configuration Editor; Created on release #T.13.71 vlan 1 name "DEFAULT_VLAN" untagged 1-8,10,13-16,18-23,A1-A4 ip address 100.100.100.17 255.255.255.0 no untagged 9,11-12,17,24 exit vlan 100 name "192.168.100" untagged 9,11-12,17,24 tagged 1-8,10,13-16,18-23,A1-A4 no ip address exit vlan 21 name "Users_2" tagged 1,A1-A4 no ip address exit vlan 40 name "Cafe" tagged 1,4,7,A1-A4 no ip address exit vlan 250 name "Firewall" tagged 1,4,7,A1-A4 no ip address exit vlan 70 name "DMZ" tagged 1,4,7-8,13,A1-A4 no ip address exit spanning-tree spanning-tree config-name "mstp" spanning-tree config-revision 1 spanning-tree instance 1 vlan 1 40 70 100 250 password manager password operator HP Switch 1 show spanning tree: show spanning-tree Multiple Spanning Tree (MST) Information STP Enabled : Yes Force Version : MSTP-operation IST Mapped VLANs : 2-39,41-69,71-99,101-249,251-4094 Switch MAC Address : 0021f7-126580 Switch Priority : 32768 Max Age : 20 Max Hops : 20 Forward Delay : 15 Topology Change Count : 363,490 Time Since Last Change : 14 hours CST Root MAC Address : 0004ea-845f80 CST Root Priority : 32768 CST Root Path Cost : 200000 CST Root Port : 1 IST Regional Root MAC Address : 0021f7-126580 IST Regional Root Priority : 32768 IST Regional Root Path Cost : 0 IST Remaining Hops : 20 Root Guard Ports : TCN Guard Ports : BPDU Protected Ports : BPDU Filtered Ports : PVST Protected Ports : PVST Filtered Ports : | Prio | Designated Hello Port Type | Cost rity State | Bridge Time PtP Edge ----- --------- + --------- ---- ---------- + ------------- ---- --- ---- A1 | Auto 128 Disabled | A2 10GbE-CX4 | 2000 128 Forwarding | 0021f7-126580 2 Yes No A3 10GbE-CX4 | Auto 128 Disabled | A4 10GbE-SR | Auto 128 Disabled | HP Switch 1 Logging: I removed the date / time fields since they are inaccurate (no NTP configured on these switches) 00839 stp: MSTI 1 Root changed from 0:a44c11-a67c80 to 32768:0021f7-126580 00839 stp: MSTI 1 Root changed from 32768:0021f7-126580 to 0:a44c11-a67c80 00842 stp: MSTI 1 starved for an MSTI Msg Rx on port A4 from 0:a44c11-a67c80 00839 stp: MSTI 1 Root changed from 0:a44c11-a67c80 to 32768:0021f7-126580 00839 stp: MSTI 1 Root changed from 32768:0021f7-126580 to 0:a44c11-a67c80 00839 stp: MSTI 1 Root changed from 0:a44c11-a67c80 to ... HP Switch 2 Configuration: ; J9146A Configuration Editor; Created on release #W.14.49 vlan 1 name "DEFAULT_VLAN" untagged 1,3-17,21-24,A1-A2,B2 ip address 100.100.100.36 255.255.255.0 no untagged 2,18-20,B1 exit vlan 100 name "192.168.100" untagged 2,18-20 tagged 1,3-17,21-24,A1-A2,B1-B2 no ip address exit vlan 21 name "Users_2" tagged 1,A1-A2,B2 no ip address exit vlan 40 name "Cafe" tagged 1,13-14,16,A1-A2,B2 no ip address exit vlan 250 name "Firewall" tagged 1,13-14,16,A1-A2,B2 no ip address exit vlan 70 name "DMZ" tagged 1,13-14,16,A1-A2,B2 no ip address exit logging 192.168.100.18 spanning-tree spanning-tree 1 path-cost 500000 spanning-tree config-name "mstp" spanning-tree config-revision 1 spanning-tree instance 1 vlan 1 40 70 100 250 HP Switch 2 Spanning Tree: show spanning-tree Multiple Spanning Tree (MST) Information STP Enabled : Yes Force Version : MSTP-operation IST Mapped VLANs : 2-39,41-69,71-99,101-249,251-4094 Switch MAC Address : 0024a8-cd6000 Switch Priority : 32768 Max Age : 20 Max Hops : 20 Forward Delay : 15 Topology Change Count : 21,793 Time Since Last Change : 14 hours CST Root MAC Address : 0004ea-845f80 CST Root Priority : 32768 CST Root Path Cost : 200000 CST Root Port : A1 IST Regional Root MAC Address : 0021f7-126580 IST Regional Root Priority : 32768 IST Regional Root Path Cost : 2000 IST Remaining Hops : 19 Root Guard Ports : TCN Guard Ports : BPDU Protected Ports : BPDU Filtered Ports : PVST Protected Ports : PVST Filtered Ports : | Prio | Designated Hello Port Type | Cost rity State | Bridge Time PtP Edge ----- --------- + --------- ---- ---------- + ------------- ---- --- ---- A1 10GbE-CX4 | 2000 128 Forwarding | 0021f7-126580 2 Yes No A2 10GbE-CX4 | Auto 128 Disabled | B1 SFP+SR | 2000 128 Forwarding | 0024a8-cd6000 2 Yes No B2 | Auto 128 Disabled | HP Switch 2 Logging: I removed the date / time fields since they are inaccurate (no NTP configured on these switches) 00839 stp: CST Root changed from 32768:0021f7-126580 to 32768:0004ea-845f80 00839 stp: IST Root changed from 32768:0021f7-126580 to 32768:0024a8-cd6000 00839 stp: CST Root changed from 32768:0004ea-845f80 to 32768:0024a8-cd6000 00839 stp: CST Root changed from 32768:0024a8-cd6000 to 32768:0004ea-845f80 00839 stp: CST Root changed from 32768:0004ea-845f80 to 32768:0024a8-cd6000 00435 ports: port B1 is Blocked by STP 00839 stp: CST Root changed from 32768:0024a8-cd6000 to 32768:0021f7-126580 00839 stp: IST Root changed from 32768:0024a8-cd6000 to 32768:0021f7-126580 00839 stp: CST Root changed from 32768:0021f7-126580 to 32768:0004ea-845f80

    Read the article

  • Disabling RAID feature on HP Smart Array P400

    - by Arie K
    I'm planning to use ZFS on my system (HP ML370 G5, Smart Array P400, 8 SAS disk). I want ZFS to manage all disks individually, so it can utilize better scheduling (i.e. I want to use software RAID feature in ZFS). The problem is, I can't find a way to disable RAID feature on the RAID controller. Right now, the controller aggregates all of the disks into one big RAID-5 volume. So ZFS can't see individual disk. Is there any way to acomplish this setup?

    Read the article

  • Redhat Kernel patching advice

    - by AndyM
    An audit has pointed out that a RHEL server I manage has not had the latest kernel patches applied. I'm confused about kernel patching and within RHEL in relation to RHEL dot releases i.e 5.2 , 5.3 ,5.4 ..... Can someone answer these questions ? If I want to stay at a dot release of RHEL, say 5.4, can apply just updates to the 5.4 kernel or will applying kernel updates bring the server to a later dot release by default? The reason for this question is that I have applications that are only supported on say RHEL5.4 and going to a more recent dot release of RHEL 5 would break the support. I have some HP psp hba drivers compiled against the currently installed kernel, will applying a kernel update break these drivers as they were complied against the orginal kernel ? Anything else I need to look out for with regards to kernel patching ?

    Read the article

  • RAID P410i and P812 performance issues

    - by Alexey
    I'm having much trouble with I/O performance of HP DL360 server with two RAID controllers - P410i and P812, Windows Server 2008, 36 GiB RAM and 16 x Intel Xeon x5550. The server runs a bunch of tasks producing heavy sequential I/O, and after about 20-30 minutes of intensive work it looks like the tasks are stuck, not using CPU and with enough free memory (so this cannot be a bottleneck). The same tasks were running quite well on the older server (Windows Server 2003, 4 x Intel Xeon, 12 GiB RAM). RAID cache is present, write-cache battery is installed. Cache is configured as 25% readahead/75% writeback. The swap file resides on the logical disk served by P410i and other logical disks are on P812. Can someone tell me what can be the matter of this? Is this a hardware problem or misconfiguration?

    Read the article

  • Extend RAID 1 (HP SmartArray P410i) running Linux

    - by Oliver
    I took over a fairly simple server setup with the following RAID 1 config running Ubuntu 11.10 (Kernel 3.0.0-12-server x86_64): => ctrl all show config Smart Array P410i in Slot 0 (Embedded) (sn: removed) array A (SAS, Unused Space: 1335535 MB) logicaldrive 1 (279.4 GB, RAID 1, OK) physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 1 TB, OK) physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 1 TB, OK) Initially there were two 300GB disks that got replaced by 1TB disks and I now have to extend the logical volume to use that extra space. However, when trying to do so I get the following warning: => ctrl slot=0 ld 1 modify size=max Warning: Extension may not be supported on certain operating systems. Performing extension on these operating systems can cause data to become inaccessible. See ACU documentation for details. Continue? (y/n) Is it safe to say yes or am I at risk of corrupting the file system / loosing data? Rearranging and extending the file system afterwards shouldn't be an issue as I can take the server offline and boot from a gparted live disk. Here's the config of the RAID controller in use: => ctrl all show detail Smart Array P410i in Slot 0 (Embedded) Bus Interface: PCI Slot: 0 Serial Number: removed RAID 6 (ADG) Status: Disabled Controller Status: OK Hardware Revision: Rev C Firmware Version: 5.12 Rebuild Priority: Medium Expand Priority: Medium Surface Scan Delay: 15 secs Surface Scan Mode: Idle Wait for Cache Room: Disabled Surface Analysis Inconsistency Notification: Disabled Post Prompt Timeout: 0 secs Cache Board Present: False Drive Write Cache: Disabled SATA NCQ Supported: True And the partition table: Number Start End Size Type File system Flags 1 1049kB 274GB 274GB primary ext4 boot 2 274GB 300GB 25.8GB extended 5 274GB 300GB 25.8GB logical linux-swap(v1)

    Read the article

  • RAID5 on SmartArray P410i online resize

    - by datacompboy
    I have P410i+256M Cache without battery backup. My RAID5 was build over 3*136GB disks, now all disks were replaced to a 3*300GB array. How can I extend it to use the whole space? HPacucli doesn't allows that, I think this might be because no battery is present. I have a redundant power supply. All data is mirrored over DRBD to a secondary server, so I can try to resize with a chance of loss of data in case of power failure, but I prefer to have an online resize.

    Read the article

  • Convert RAID-0 to RAID-1 on HP ML350G6 with P410i zero memory

    - by JLe
    I have an HP ML350 G6 with a P410i zero memory RAID controller. As far as I can understand that means I can't expand a current single drive "RAID-0" configuration to a RAID-1 using the HP Offline ACU without installing memory and BBWC. Is that correct? What makes me think about this is the fact that expanding RAID-0 to RAID-1 should be pretty similar to replacing a failed drive in an already existing RAID-1? So then why can't I expand without memory and BBWC? Is my best option otherwise to (i) use Ghost to capture the disk, create a new RAID-1 with the existing drive and a new one or (ii) buy memory+BBWC and do it online? Thanks

    Read the article

  • CentOS Installation on a Cisco MCS 7800

    - by William
    I'm having some problems installing CentOS 5.5 Final (i386) onto my server, a Cisco MCS 7800. The problem comes very early into the installation. When the welcome screen comes up and gives you the option on how to boot into the DVD, I'll press enter to go into the graphical installer. The screen will then have a blinking cursor in the top left of the screen and will never go away (I thought that it just might need time but I let it sit for over 5 hours). I then booted into it again and tried using Linux Text thinking it was a problem with the graphical installer. That didn't work, same problem. Then I tried a DVD of RHEL 5 and got the same problem, both graphical and Linux text. At this point I think it's a hardware problem. The server has 2GB of ECC RAM, 1 Pentium 4 CPU @ 3.06GHZ and 2 WD Hard Drives (80GB) configured for RAID 0. (There is also an option in the BIOS for what OS type and that is set to Linux.) If anyone has any idea what is going on, it would be helpful. Edit Typing "text" doesn't change a thing. Still stuck at the blinking cursor. I looked it up and it's really the same thing as typing "linux text", which as stated in the first part of my question, I've already done.

    Read the article

  • ZFS SAS/SATA controller recommendations

    - by ewwhite
    I've been working with OpenSolaris and ZFS for 6 months, primarily on a Sun Fire x4540 and standard Dell and HP hardware. One downside to standard Perc and HP Smart Array controllers is that they do not have a true "passthrough" JBOD mode to present individual disks to ZFS. One can configure multiple RAID 0 arrays and get them working in ZFS, but it impacts hotswap capabilities (thus requiring a reboot upon disk failure/replacement). I'm curious as to what SAS/SATA controllers are recommended for home-brewed ZFS JBODs. In addition, how does battery-backed write cache (BBWC) play into the solution?

    Read the article

  • Monitoring Dell/HP Servers Running ESXi (Free)

    - by Untalented
    What are you all doing to monitor ESXi servers that run the free edition? With the lack of SNMP support, it seems fairly limited to me. What'd I'd like to be able to do is get some type of alert when a drive or other hardware fails. I've seen a few articles on getting OpenManage installed on an ESXi box (to rebuild an array), but it seems to be quite a pain as well. Even if I get OpenManage working, I won't have alerts without SNMP. Any comments, input, or guidance would be greatly appreciated.

    Read the article

  • hp DL380 G4 won't boot with disk plugged into front USB

    - by Kev
    We outgrew a few older external USB backup drives, and purchased WD My Passport 1 TB USB 3.0 drives to replace them. When they are plugged into the front of our G4, it will blink forever after the BIOS (which is current, BTW) and never boot, even though the USB disks are not "bootable" per se. Our old drives did not exhibit this behaviour (so I don't think it's this type of issue that I've read about other servers.) The old drives were USB 2.0, but this shouldn't make a difference, AFAICT--the specs say all of the G4's USB ports are the same, 2.0, anyway, so I'm not sure how one port would handle a USB 3.0 device better than another. If we plug the new drives in one of the back slots, it boots fine. What's the cause? My concern is that the front USB port, and possibly the motherboard, might be starting to die. (We are experiencing other strange issues with them, or were initially, like intermittent file permissions errors despite wide-open ACL on these local drives, but some serverfault users have me convinced they may be coincidental software/security related issues.)

    Read the article

  • HP DL370 G6 expansion

    - by user72185
    Hi, we are running a HP DL370 server with 6 x 300 gb disks on RAID 5. Due to a Windows update causing our server to fail recently, we couldn't access the data. I now want to separate the data from the OS (Windows server 2008 r2) so that if anything like that happens again, we can route everyone through a separate server. I have seen these HP storageworks enclosures (msa70) and have a couple of questions: Can I just take out our 2.5 inch 10k SAS drives, install them in the new Storageworks NAS and hey presto we would be up and running? If I wanted to then add another drive (I think there are 25 bays), can I just insert a blank but identical drive and the RAID 5 would dynamically expand to incorporate the new drive. Many thanks Adrian

    Read the article

  • What is the Name of this Type of Screw? (from for HP quick deploy rail kit in a square hole Rack)

    - by kockiren
    I need the name of the screw for the HP quick deploy rail kit. The screw clicks into the square holes of the rack. It is a Gen4 Rail kit but the screw is like the Gen8 Rail kit ones. I called HP support, but they couldn't really help me. Unfortunately the rack manual does not name this screw either. After googling a while, I found the compatible "Thumb Style Rack Screws". It would do the job but isn't exactly what I am looking for. So, what is the name of the pictured screw.

    Read the article

  • VMWare ESXi 5 - Expanded RAID 5 array - cannot access datastore

    - by Dayton Brown
    I'm using VMWare ESXi 5 and had a 2 TB RAID 5 setup on an HP DL360 with a P400i RAID card. I added two more 1 TB drives and using the SmartStart ACU, added the drives and expanded the logical disk. Now after booting back to ESXi, the server boots, but lists no available persistent storage. I've rescanned multiple times to no avail: the Datastore doesn't show up. I booted to GParted and the 1.8TB partition shows up, but it shows as unknown. Anyone have any good ideas? EDIT: Final Solution So after much gnashing of teeth, it was fairly simple to solve. I purchased an eSata 2 TB external drive and a PCI eSata card for my server. I then used Clonezilla to image the current partitions to my new external drive. You have to check "don't check drive sizes" in advanced mode, otherwise it will yell at you for have a smaller drive. For some reason my PCI card wouldn't boot on my HP server, so I hooked the drive up to another desktop I had, booted to VMWare, and copied the vmdk's to another drive. I'm going to blow out the RAID config and then create 1.5TB logical drives.

    Read the article

  • Rack Mounting a Server with hot air vents on the top?

    - by Adam
    We just got a couple of HP DL360 G7's, and I notice it has vents on the top. More hot air seems to exit through these vents than it does anywhere on the back. All our servers in the past have always vented all the hot air through the back. How are these servers with top vents supposed to be mounted? Everyone always says airflow is best by not leaving gaps on the rack, but it seems like a server right on top of it would receive a lot of heat.

    Read the article

  • How to turn off power metering in HP ILO2?

    - by Baron Throw
    I have an issue with all of my RHEL 5.3 servers, where HP iLo2 power meter checks the power draw of the power supply on the server. However this gets passed to the /var/log/messages in our host, and eventually fills up the logs. Anyone have any idea how to completely disable power meter option in iLo? I checked google and iLo2 documentation provided from HP, but found nothing that tells you how to disable it / turn it off. Maybe some CLI command? Im not sure. The message is: Aug 18 10:11:03 KAMIL-SERVER1 ipstor_hwmond: IPSTOR||1408371063||E||11788||sensors||Power Meter = 108.000 Watts [ low=na high=na]

    Read the article

  • Cloning a linux system from sdx to cciss

    - by churnd
    I have an HP ML 310 server running CentOS Linux 5.5. I'm buying a RAID card (LSI 9260-8i) to set up a mirrored OS drive. Right now, the boot drive is set up with GRUB installed on the MBR of /dev/sda & has a 100MB /boot partition for /dev/sda1, then the rest is configured in LVM with a 20GB with a 20GB VG for the root partition & ~80GB VG for home. The new disk sizes will also be slightly larger as well. What is the best way to clone the boot drive to the new CCISS device?

    Read the article

  • Red Hat 5.4 slow processing

    - by yucefrizk
    I'm running Red Hat Linux 5.4 on HP DL580 server with 16 processors and 64 GB of RAM. I'm connecting to the server remotely through SSH. after entering the password, it takes time to return the command line, if I click ctrl+c during this time, I'll have the command line prompt but not the correct bash prompt (I have to run bash to pass to my correct prompt). I tried to install Apache on the server, ./configure took 4 hours to finish instead of 1 or two minutes, Oracle installation same behavior. Server Disks are mirrored using RAID controller. any idea what could be the reason of this slowness?

    Read the article

  • CentOS Installation on a Cisco MCS 7800

    - by William
    Hello, I'm having some problems installing CentOS 5.5 Final (i386) Onto my server, a Cisco MCS 7800. The problem comes very early into the installation. When the welcome screen comes up ans gives you the option on how to boot into the DVD, Ill press enter to go into the graphical installer. The Screen will then have a blinking cursor in the top left of the screen and will never go away (I thought that it just might need time but I let it sit for over 5 hours.) I then booted into it again and tried using Linux Text thinking it was a problem with graphical installer. That didn't work, same problem. Then I tried a DVD of RHEL 5 and got the same problem, both graphical and Linux text. At this point i think its a hardware problem. The Server has 2GB of ECC RAM, 1 Pentium 4 CPU @ 3.06GHZ and 2 WD Hard Drives (80GB) Configured for RAID 0. ( Also there is a option in the BIOS for what OS type and that is set to Linux.) If anyone has any idea what is going on, it would be helpful. ================Edit================== ooshro, typing "text" doesn't change a thing. still stuck at the blinking cursor. I looked it up and its really the same thing as typing "linux text", which as stated in the first part of my question, i've already done.

    Read the article

  • Reusing Raid 5 Drive?

    - by User125
    We have two servers (ML530 G2 and DL380G2) w/ identical HP 10K RPM SCSI drives w/ a raid 5. One is decommissioned and the other will be decommissioned shortly. However, one of the drives on the production server had a drive failure. My hope was to take one of the drives from the decommissioned server and pop it into the production server. Both are running RAID 5. I broke the array on the decomm. server. To my knowledge, that should have wiped out all the volume and partition information. However, I do not know if it is safe to then take a drive from the decomm'ed server and replace the failed drive. Will the existing array see it as a replacement drive, wipe it and rebuild? Or will it fail because it was used in an array before. Are there any remnant data that resides on the drives after deleting a raid 5 array? These servers are 10-15 years old, so we're just trying to keep them alive until we decommission it. I'm not looking to pay a premium to find a vendor that still sells replacement drives for this system.

    Read the article

  • HP DL380 G5 Predictive failure of a new drive

    - by CharlieJ
    Consolidated Error Report: Controller: Smart Array P400 in slot 3 Device: Physical Drive 1I:1:1 Message: Predictive failure. We have an HP DL380 G5 server with two 72GB 15k SAS drives configured in RAID1. A couple weeks ago, the server reported a drive failure on Drive 1. We replaced the drive with a brand new HDD -- same spares number. A few days ago, the server started reporting a predictive drive failure on the new drive, in the same bay. Is it likely the new drive is bad... or more likely we have a bay failure problem? This is a production server, so any advice would be appreciated. I have another spare drive, so I can hot swap it if this is a fluke and new drive is just bad. THANKS! CharlieJ

    Read the article

  • Uncorrectable machine check

    - by GregC
    I am experiencing rare but real unrecoverable machine checks on HP DL370 G6 dual-core Xeon server. I ran memtest86+ before, and ran CPU-intensive operations without any problems. In your opinion, does this indicate a real problem, or is it normal and expected behavior? How would you approach this problem? EDIT after some troubleshooting, it seems that these machine checks, as well as problems when showing device manager can be traced back to NC375i NICs. All is well when the NICs are not in the server. Further improvements to stability of HP Gen6 with Intel Xeon have been brought in with BIOS update in September 2013 HP Update DVD. Intel's newer microcode makes these CPUs much more stable. We haven't seen hardware-related BSODs since the update in September.

    Read the article