  • How HP D2700 disk enclosure is monitored for alarms via SNMP

    - by VSAC
    We have HP D2700 disk enclosure and we would like to monitor D2700 (connected to HP Proliant DL360G8) for alarms.I have following questions regarding this. What are the options available for reporting D2700 hardware alarms (disk failure, power failure) via SNMP? We understand the D2700 to have an Ethernet interface for controller A and B and alarms are available via SNMP via this interface. Can anyone provide the actual alarms via this interface? (MIB and alarm list) As we have a number of D2700’s and would like to minimize the number of physical connections to the switch and associated IP addresses; Is there a mechanism to monitor the D2700 from the SCSI connected HPDL360 and raise SNMP alarms from the DL360 for hardware failures on the D2700? If so can anyone provide details and the actual alarms and MIB via this mechanism? Thanks!

    Read the article

  • NIC Teaming HP Server running Win2003

    - by Colm
    Hello everyone. I'm new to server NIC TEaming. I have a HP ProLiant DL360 G4p running Win2003 with 2 NICs , only one is currently active. I'd like to activate the 2nd NIC connected (in a active/passive state) to a 2nd switch with only one IP address and ideally only one mac layer address. The 1st switch is a Cisco 2960G and the 2nd is a Cisco C3560G. There are VLANS, RSTP and PAGP in use already. Can someone give me an idea, in broad terms , of what technology/protocols I should be investigating (HSRP, SLB/TLB Teaming etc.) ? I can provide more info if needed. Thanks, Colm.

    Read the article

  • Link rate between EMC DAE and HBA

    - by Johan Christensson
    I have a EMC DAE (KTN-STL4) drive cage directly connecconnected to a HP Proliant server using a QLogic QLE2560 HBA. I'm using copper cable between the HBA card and the DAE. On the controller card in the DAE there is a label that states "4Gb". I'm guessing that this means 4Gbit/s. But if I set the HBA card to "Auto speed" it negotiate 2Gbit/s, and if I hard set it to 4Gbit/s I end up with no link. Why is this? Isn't the DAE controller card capebel of link speed higher then 2Gbit/s or is it the copper cable that limits the speed, or is it the interface used between the DAE and Qlogic HBA that is the problem? I have been browsing for HSSDC-FC converters and they always seems to på rated at ~2Gbit/s. If this is the limit, why does it say 4Gb on the controller cards in the DAE?

    Read the article

  • Clone remote CentOS server to local test server?

    - by dannymcc
    We have a dedicated server running ContOS 5.5. The server runs our Magento store and a basic php website with mysql. I have a spare rack server in my office (HP ProLiant DL360 G4) that has more than enough storage space to store a duplicate of our dedicated server. I would like to clone the dedicated server entirely and have a local duplicate. It wouldn't need to be kept in sync because I can do that with GIT. The reason I want to do this is simple; learn more about the dedicated server and CentOS. Is this possible? I have SSH access to the dedicated server and obviously complete access to the local server.

    Read the article

  • Dual Home HP Server running Win2003

    - by Colm
    Hello everyone. I'm new to server dual homing. I have a HP ProLiant DL360 G4p running Win2003 with 2 NICs , only one is currently active. I'd like to activate the 2nd NIC connected (in a active/passive state) to a 2nd switch with only one IP address and ideally only one mac layer address. The 1st switch is a Cisco 2960G and the 2nd is a Cisco C3560G. There are VLANS, RSTP and PAGP in use already. Can someone give me an idea, in broad terms , of what technology/protocols I should be investigating (HSRP, SLB Teaming etc.) ? I can provide more info if needed. Thanks, Colm.

    Read the article

  • VMware Virtualisation - Convert 64bit Windows Server to 32bit VM?

    - by dannymcc
    I have just started playing around with Vmware sphere and have the hypervisor OS installed on a spare HP ProLiant DL360 G4. I have created a test virtual machine running Ubuntu which has worked well. As a test project I wanted to convert a powered on server running Windows Server 2008 64bit into a virtual machine. As soon as I ran the Vmware Go software to start the conversion it became apparent that I cannot run 64bit guest OS's on that particular server. So, is there a way of migrating 64bit to 32bit during the conversion?

    Read the article

  • Software RAID 10 on Linux

    - by vpetersson
    For a long time, I've been thinking about switching to RAID 10 on a few servers. Now that Ubuntu 10.04 LTS is live, it's time for an upgrade. The servers I'm using are HP Proliant ML115 (very good value). It has four internal 3.5" slots. I'm currently using one drive for the system and a RAID5 array (software) for the remaining three disks. The problem is that this creates a single-point-of-failure on the boot drive. Hence I'd like to switch to a RAID10 array, as it would give me both better I/O performance and more reliability. The problem is only that good controller cards that supports RAID10 (such as 3Ware) cost almost as much as the server itself. Moreover software-RAID10 does not seem to work very well with Grub. What is your advice? Should I just keep running RAID5? Have anyone been able to successfully install a software RAID10 without boot issues?

    Read the article

  • Separating user resources - Windows Server 2008 (Terminal Server)

    - by Christopher Wilson
    At the moment I am running a Windows Terminal Server 2008 for around 10 clients that use the server to run programs and access data. Is there anyway to separate the resources of each user so that they do not impact each other in terms of resources. User 1: Opens program User 2: Notices slow down I have looked into using Windows System Resource Manager but do not know if it provides what I need and if there are any other 3rd party tools that also provide this functionality. Any answer is appreciated. Server Specs: HP ProLiant ML110 G7 Processor: Intel® Xeon® E3-1220 (4 core, 3.1 GHz, 8MB, 80W, 1333/t) RAM: 12GB DDR3 ECC 1TB HDD

    Read the article

  • IP KVM switch, or serial console box for remote admin?

    - by grahzny
    We have a small server farm (11 now, may add more in the future) of HP Proliant DL160 G6s. They all run either Linux (server only, no X11) or VMware ESX. We had intended to get models with iLO, in case BIOS-level remote admin became an issue, but that didn't happen. I had an IP KVM switch recommended to me (along with some sort of Remote Reboot hardware.) I've since realized that none of our machines need GUI administration, so perhaps a serial console switch would be a cheaper and more appropriate option. Something like this: http://www.kvm-switches-online.com/serimux-cs-32.html Do you folks have an opinions on which way is a better choice? Should we go for the ease of setup (plug and go, instead of turning on the feature in the BIOS and making sure the serial settings are correct) and the flexibility of an IP KVM switch even with the extra cost? Or is a serial console switch just fine?

    Read the article

  • How to select a server that supports Windows scheduled file IO

    - by Kristof Verbiest
    Background: I am developing an application that needs to read data from disk with a fairly consistent throughput. It is important that this throughput is not influenced by other actions that happen on the disk (e.g. by other processes). For this purpose, I was hoping to use the 'Scheduled File I/O' feature in Windows (throught the GetFileBandwithReservation and SetFileBandwithReservation functions). However, this StackOverflow question has thought me that this feature is only available if the device driver supports it. Currently I have no computer at my disposition that seems to support this feature (I have an HP Proliant server and a Dell Precision workstation). Question: If I were to order a new server, how can I know beforehand if this feature will be supported by the device driver? How 'upscale' does the server have to be? Has anybody used this feature with success and cares to share his experiences?

    Read the article

  • Windows Server 2003 not automatically assigning drive letter to external drives

    - by Chris
    My newly rebuilt Windows Server 2003 doesn't automatically assign drive letters to external usb devices. I have to manually open the Disk Management Console and assign it a drive letter every time. It does this with two different drives in all USB ports. I have been doing some reading and I don't have any network drives, I have also already tried USBDLM and it doesn't seem to have made any difference. Specs: ProLiant ML150 G5 with Windows 2003 Enterprise and all updates installed. Any ideas on what I can try to resolve this problem would be greatly appreciated. Chris

    Read the article

  • Need to Extend Volume

    - by Roger Galindo
    Ok Here is where I am... I have an HP Proliant with 8 Drives configured as RAID5, and C:\Drive Disk 0 and D:\ drive Disk 1. I need to add more space to Disk 0 (C:) and have 150GB available on Disk 1 (D:). I tested the Disk Mgmt on D:\ and freed up 4GB which now shows to be Unallocated. How do I add the 4GB of Unallocated to the c:\? When I click on C:\ the Menu shows "Extend Volume" as Grayed Out not Black but the D:\ Drive shows Extend Volume as selectable/black.

    Read the article

  • windows 2000 freezing during large disk write

    - by robert
    We have a windows 2000 sp4 server which freezes up for about 1 minutes while its web-app does a ~500mb write operation. I can see the webapp start to do I/O activity (through process explorer) then the RDP session becomes unresponsive, you can click on windows and buttons but nothing happens. When the disk write finally finishes the session 'catches up' on all the mouse clicks you did during the freeze in a mad flurry of window activity and the server returns to normal. During the freeze the web-app stops as well. The same behaviour happens on the console of the server. (so I know its not a network thing) Nothing appears in the Event logs. Its like nothing happened. I have upgraded all the HP hardware drivers to the latest proliant support pack. And also run a HP hardware diagnostics which found nothing wrong. What would cause a disk write to lock the rest of the OS?

    Read the article

  • Non-ECC memory with ZFS: a stupid idea?

    - by iconoclast
    I'm the proud new owner of an HP Proliant Microserver N40L, and planning to upgrade the (obviously paltry 2 GB of) memory to the maximum of 16 GB. (Theoretically 8 GB is the limit, but empirically 16 GB has been shown to work.) Some guides advise that ECC memory is not that important, but I'm not so sure I believe this. I've installed FreeNAS and am planning to add ZFS volumes as soon as my new hard drives arrive. Would it be stupid to skimp and get non-ECC memory for a ZFS-based NAS? If it's necessary, then I'll bite the bullet, but if it's just paranoia, then I'll probably skip it.

    Read the article

  • spontaneous hard disk password

    - by sc
    I had an HP proliant server go down recently. All of the sudden the sas controller (e200i) would not see any of the physical disks. New disks were detected just fine. I thought it was odd that all 6 disks would go down at one time so sent them to a data recovery firm to find out what happened. I'm being told that, somehow, all of the disks were spontaneously password protected. These are Hitachi 2.5" drives and I guess this is something of a known issue. The company has worked for a while to try and recover them, with no luck. Has anyone had experience with this? Any recommendations for how to recover the drives or a company that might have the expertise to do so?

    Read the article

  • Drive stopped working on windows server 2003 and I receive a "controller error"

    - by Durden81
    I can access the server in safe mode. I have a Proliant 360 Hp server with Windows server 2003 R2. The event viewer is completely filled up with this error: the driver detected a controller error on Device\Harddisk3\DR3 I individuated the drive affected. It is drive H that is a secondary non mirrored drive. When I access anything on that drive I receive: "the request could not be performed because of an I/O device error" What should I do? Is this just a driver issue or a hard drive failure? Please give me a quick help as my websites are offline due to this. Any suggestion is welcome!

    Read the article

  • Creating ip alias on bonded interface ie. bond0:1

    - by bobothechimp
    System: HP Proliant DL360 G5 running CentOS 5.4 Bonded interface is working fine for a long time. I just went to add an alias the way I always have on a regular interface, and on first check it works (pinging on the local box) but it is not accessable from outside (iptables is turned off). In addition with this setup the normal network response started to decline, hanging for around a minute before I could get a prompt on login. Here are my config files: [root network-scripts]# cat ifcfg-eth0 DEVICE=eth0 BOOTPROTO=none ONBOOT=yes MASTER=bond0 SLAVE=yes USERCTL=no [root network-scripts]# cat ifcfg-eth1 DEVICE=eth1 BOOTPROTO=none ONBOOT=yes MASTER=bond0 SLAVE=yes USERCTL=no [root network-scripts]# cat ifcfg-bond0 DEVICE=bond0 BONDING_OPTS="mode=1 miimon=100" BOOTPROTO=none ONBOOT=yes NETWORK=10.2.1.0 NETMASK=255.255.255.0 IPADDR=10.2.1.11 USERCTL=no [root network-scripts]# cat ifcfg-bond0:1 DEVICE=bond0:1 BOOTPROTO=static ONBOOT=yes NETWORK=10.2.1.0 NETMASK=255.255.255.0 IPADDR=10.2.1.12 USERCTL=no any thoughts?

    Read the article

  • Zfs Drive config on FreeNas

    - by Martyn
    Couple of related questions. Background: I have a stock of drives lying about that I want to use in a HP Proliant Microserver which has a 4 slot SAS cage with FreeNas. I don't want to spend any more on parts. 1) With Zfs and RAIDZ, how bad would it be to mix 2 x 1TB Seagate Barracudas with 2 x 1TB WD Green drives. The latter Green drives are I believe only 5,400 RPM, but I can't find that info for sure. 2) Which would be better, the above mis-match in a RAIDZ or 2 x 3TB Seagate Barracuda in a mirror. Considering both performance and data security 3) I have a spare 250GB drive and a spare SATA slot (for optical drive, not sure on speed) as well, would that be a performance gain to use that for the ZIL and L2ARC (over just using the main drives). Thanks in advance.

    Read the article

  • Raid 5 scsi fault

    - by HaLaBi
    I have no much knowledge about servers and I was looking all day around the internet about finding a solution to my raid 5 problem. All of a sudden two disks failed. The server won't boot (HP Proliant, windows 2003 R2, very old maybe 10 years old). I know that if one disk is faulty then I can add a new disk and rebuild it and things will be fine, the problem is two went faulty :( is this normal? two at the same time? is there any other thing I can do and I am not aware of? other than taking them out and reinserting them back? Windows won't boot. The Array menu shows that disks 0 and 4 are "Missing". Any other tricks or things to do? It is important because for some unknown reason the back up job did not work for a month and I just found out, so I need to make these raid 5 back online again.

    Read the article

  • Reset my windows server 2003

    - by Tim Thoirp
    I was recently given an HP Proliant Server from a friend as a gift. It has Windows Server 2003 installed on it. When I go to boot the system however to log in to Windows Server 2003 it requires an Admin password. I can't figure out the password and my friend doesn't know it either as it has been years since hes used the machine. I don't care about any of the data on the machine I just want to have a new clean version of Windows server 2003 running on it. Any advice would be helpful? And no I don't want to pay for a password cracking tool. Thanks

    Read the article

  • Windows backups to VM Esxi

    - by Martyn
    I'm very new to ESXi, so apologies if this is a silly question. I have ESXi 5.1 running running on HP Proliant Microserver with internal LUNs RAIDed with HP P410 Smart Array card. I have 2 Windows Server 2012 VMs running as Domain controllers. These are being backed-up up with GhettoVCB to a dedicated datastore hosted on LUNs on a eSata external device. I have several Windows 8 & 7 PC's connected to this domain. I want to back up these Windows PCs, via the built in backup software, ideally to the external eSata device as well. What do I need to do to have the Windows PC's see the datastore? I assume I could create a VM for FreeNas or something, or share out the datastore via one of the Windows Server 2012 VMs. Both those options seem a little bit of an over kill?

    Read the article

  • Three disk (possibly RAID) data recovery

    - by Martin
    I have on my desk three 160 GB disks that were once part of an HP Proliant Windows 2003 Server. They may have been part of a RAID configuration of some sort. They may or may not be damaged in some way. When I interface them via USB, one of them shows up as a drive, but unformatted. The others show up as uninitialized disks in manager. An alternative explanation is that the two drives were simply not unused. What's my first step? I've recovered data off damaged drives before but never had anything to do with RAID configs. How can I even tell if any type of RAID was used?

    Read the article

  • HP DL380 Losing Drive Array

    - by jidl
    I have an HP Proliant DG380 G7 dropping one of it's arrays every hour, on the hour, for 2-5 minutes. The OS is SBS 2011 Standard, the servers runs Exchange, DC, files & Trend WFBS 8. I can watch the D Drive disappear for the duration of the problem - then it just comes back up and all is well again. There is no loss of network connectivity, although the mapped drives also disappear. We thought it might be to do with Sharepoint / VSS writers failing but it looks as though this is a symptom rather than cause. It survives a reboot. Any ideas as to what could be running on a regular schedule like this?

    Read the article

  • Oracle Linux Delivers Top CPU Benchmark Results on Sun Blades

    - by sergio.leunissen
    From the Performance and Best Practices blog: Fresh SPEC CPU2006 results for Sun Blade X6275 M2 Server Modules running Oracle Linux 5.5. The highlights: The dual-node Sun Blade X6275 M2 server module, equipped with two Intel Xeon X5670 2.93 GHz processors per node and running the Oracle Enterprise Linux 5.5 operating system delivered the best SPECint_rate2006 and SPECfp_rate2006 benchmark results for all systems with Intel Xeon processor 5000 sequence. With a SPECint_rate2006 benchmark result of 679, the Sun Blade X6275 M2 server module, with two compute nodes per blade, delivers maximum performance for space constrained environments. Comparing Oracle's dual-node blade to HP's dual-node blade server, based on their single node performance, the Sun Blade X6275 M2 server module SPECfp_rate2006 score of 241 outperforms the best published HP ProLiant BL2X220c G5 server score by 3.2x. A single node of a Sun Blade X6275 M2 server module using 2.93 GHz Intel Xeon X5670 processors delivered 37% improvement in SPECint_rate2006 benchmark results and 22% improvement in SPECfp_rate2006 benchmark results compared to the previous generation Sun Blade X6275 server module. Both nodes of a Sun Blade X6275 M2 server module using 2.93 GHz Intel Xeon X5670 processors delivered 59% improvement on the SPECint_rate2006 benchmark and 40% improvement on the SPECfp_rate2006 benchmark compared to the previous generation Sun Blade X6275 server module.

    Read the article

  • Restoring an Ubuntu Server using ZFS RAIDZ for data

    - by andybjackson
    Having become disillusioned with hacking Buffalo NAS devices, I've decided to roll my own Home server. After some research, I have settled on an HP Proliant Microserver with Ubuntu Server and ZFS (OS on 1 Ext4 disk, Data on 3 RAIDZ disks). As Joel Spolsky and Geoff Atwood say with regards to backup, I can't rest until I have done a restore in all of the failure scenarios that I am seeking to protect against. Q: How to configure Ubuntu Server to recognise a pre-existing RAIDZ array? Clearly if one of the data disks die - then that is a resilvering scenario, which is well documented. If two of the data disks die, then I am into regular backup/restore land. If the OS dies and I can restore, also an easy scenario. But if the OS dies and I can't restore, then I need to recreate an Ubuntu server. But how do I get this to recognise my RAID-Z array? Is the necessary configuration information stored within and across the RAIZ array and simply need to be found (if so, how)? Or does it reside on the OS ext4 disk (in which case how do I recreate it)?