Search Results

Search found 229 results on 10 pages for 'ultra porov'.

Page 8/10 | < Previous Page | 4 5 6 7 8 9 10  | Next Page >

  • ffmpeg - h264 to xvid creates large file

    - by fatnic
    I'm trying to use ffmpeg to convert a h264/aac video file to an xvid/mp3 file so I can play it in my ultra-cheap media player. At the moment the converted video file is TWICE the size of the original mp4. Is there any way to get a smaller file size without loosing too much quality? Even a drop to -qmin 1 is pretty awful! The command i'm using is ffmpeg -i input.mp4 -vcodec libxvid -sameq -acodec libmp3lame -ab 128k -ac 2 output.avi And the ffmpeg output is Input #0, mov,mp4,m4a,3gp,3g2,mj2, from 'input.mp4' Metadata: major_brand : isom minor_version : 1 compatible_brands: isomavc1 Duration: 01:34:27.69, start: 0.000000, bitrate: 1520 kb/s Stream #0.0(und): Video: h264, yuv420p, 720x304 [PAR 1:1 DAR 45:19], 1387 kb/s, 25 fps, 25 tbr, 25k tbn, 50 tbc Stream #0.1(und): Audio: aac, 48000 Hz, stereo, s16, 128 kb/s Output #0, avi, to 'output.avi': Metadata: ISFT : Lavf52.64.2 Stream #0.0(und): Video: mpeg4, yuv420p, 720x304 [PAR 1:1 DAR 45:19], q=2-31, 200 kb/s, 25 tbn, 25 tbc Stream #0.1(und): Audio: libmp3lame, 48000 Hz, stereo, s16, 128 kb/s Stream mapping: Stream #0.0 -> #0.0 Stream #0.1 -> #0.1

    Read the article

  • Desktop PC does not power up on power button

    - by hIpPy
    When I press the power button on my desktop, it does not power up completely. Before I press the power button, I see lights on the motherboard. Everything is normal. On power button press, the fans on the cpu, graphics card and motherboard start to spin a little for a second or two and then they stop. No beeps during this process. It has been doing this for a while now but it used to start up after some trials. Once it starts up, I have NO issues at all like random shutdowns so it is not an issue with OS. Update: I left the desktop off for a few days and it started. I'm just guessing here but it seems as if the PSU (Antec TP2-550ATX) is dying out and does not have enough power now - just a guess. It's an old desktop assembled in 2005 but I have maintained it well. Update: I always keep the desktop running and I never shut it down. During updates or manual restarts, it powers up without issues. I wonder if this sheds lights on the issue. Any idea how I can narrow down the issue? ex: if I can find if the PSU is dying etc. I'd really like to fix the issue. Please help. Thanks. Below is the complete configuration. DFI LAN-Party UT NF4 Ultra-D 6/23 {6.70}, Evercool EC-VC-RE 41/47C, AMD Opteron 170 2.0GHz {1.3.2.16} 1.312V 36/41C, ThermalRight SI-120, Panaflo 120×38mm OCZ Platinum 2×1GB 200MHz 2.66V 3-3-2-7 1T XFX 7800GTX 256MB 475/1250MHz {91.31}, Zalman VF900 Cu led 41/56C WD Caviar 320GB 7200RPM 16MB SATA 3Gb/s Antec TP2-550ATX Antec P180 WinXP sp3 Logitech MX310 Razer Mantis Speed BenQ FP91G+ 19" LCD 8ms DVI Creative Audigy2 ZS {4.42} BenQ DW1640 Logitech z-5300e 5.1 280W Legend: Driver versions: {} User settings: [] Voltage: V Wattage: W Temperature: C (Celsius) min/max

    Read the article

  • Is reliability reputation of mechanical keyboards overblown?

    - by Rarst
    A while back I worked up to finally buying mechanical keyboard (~$100 range, "black" switches) and was initially quite content with purchase. However just outside first year (read it - as soon as warranty expired) it started to develop repeat issues (press once, get chain of letter repeated) on multiple keys. It doesn't react to generic cleaning (up to compressed air) and searching Internet shows noticeable amount of people with similar-to-identical issues, spanning years. This makes me severely hesitant to buy another mechanical keyboard, considering: every other keyboard I ever owned, including ultra-cheap crap managed to last longer than that typing experience is nice, but not lifechanging-fan-forever nice for me my choice of mechanical keyboards is severely limited not many brands represented in local market and primarily crazy looking gamer models russian (not to mention russian and ukrainian if possible) layout excludes international ordering price tag for a meek year of use I got our of it is plain demoralizing It is obvious mechanical keyboards have their fans, but shopping around for "best fit" or getting into multiple hundreds price tags is probably not something I am highly interested in. Considering my constraints and bad experience with reliability, is it practical for me to sink more money into buying mechanical keyboard(s) again? In other words - manufacturers are beaming about how crazy reliable mechanical keyboards are. Are active long time users of such keyboards confidently of same opinion?

    Read the article

  • MySQL ADO.NET Connector & MSSQL Integration Services

    - by user1114330
    Here I am, day three... attempting to sync a data view on a Windows Vista box (64 bit) running MSSQL 2012 and Visual Studio 2010. Sanity is slipping and hunger for progress fills my attention. I went through hell trying to get the MySQL ODBC drivers to get the job but to no avail...everyone seems to be lost and all the threads I can find are solutions that do not work for me. The problem: System DSN's not being seen by SSIS. SSIS DSN Not Showing as ODBC Data Source I make the decision to try out the ADO.NET connector...and to my surprise it is actually in the selection list in data sources in SSIS. So I take off running to create a Data Flow Task, create an ADO.NET Source (a local MSSQL DB)...all is good as usual. Then I move swiftly to creating a ADO.NET Destination, enter my credentials...wow, I am selecting a database finally on my linux server! Happy thinking that I finally have figured a way to get the job done. Then I move to mappings...nope, something is wrong...I am getting an error that hurts my eyes: Pipeline component has returned HRESULT error code 0xC0208457 from a a method call. Error at Data Flow Task [ADO NET Destination [81]]: Failed to get properties of external columns. The table name you entered may not exist or you do not have SELECT permission on the table object and an alternative attempt to get column properties through connection has failed. Detailed error messages are" You have an error in your SQL syntax check the manual that corresponds to your MySQL server version for the right syntax to use near "database".tablename" at line 1. The descriptor files on path C:\Program Files (x86)\Microsoft SQL Server\110\DTS\ProviderDescriptors\ does not contain schema information for connection of type MySQL.Data.MySqlClient.MySqlConnection. So it looks like it can't the information and therefore I cannot map the tables properly. Any ideas on this would be ultra helpful...thanks in advance to All!

    Read the article

  • LVS / IPVS difference in ActiveConn since upgrading

    - by Hans
    I've recently migrated from an old version of LVS / ldirectord (Ultra Monkey) to a new Debian install with ldirectord. Now the amount of Active Connections is usually higher than the amount of Inactive Connections, it used to be the other way around. Basically on the old load balancer the connections looked something like: -> RemoteAddress:Port Forward Weight ActiveConn InActConn -> 10.84.32.21:0 Masq 1 12 252 -> 10.84.32.22:0 Masq 1 18 368 However since migrating it to the new load balancer it looks more like: -> RemoteAddress:Port Forward Weight ActiveConn InActConn -> 10.84.32.21:0 Masq 1 313 141 -> 10.84.32.22:0 Masq 1 276 183 Old load balancer: Debian 3.1 ipvsadm 1.24 ldirectord 1.2.3 New load balancer: Debian 6.0.5 ipvsadm 1.25 ldirectord 1.0.3 (I guess the versioning system changed) Is it because the old load balancer was running a kernel from 2005, and ldirectord from 2004, and things have simply changed in the past 7 - 8 years? Did I miss some sysctl settings that I should be enforcing for it to behave in the same way? Everything appears to be working fine but can anyone see an issue with this behaviour? Thanks in advance! Additional info: I'm using LVS in masquerading mode, the real servers have the load balancer as their gateway. The real servers are running Apache, which hasn't changed during the upgrade. The boxes themselves show roughly the same amount of Inactive Connections shown in ipvsadm.

    Read the article

  • 2 routers at home- how to connect with VNC?

    - by Charles Leviton
    I have two routers at home. First router is upstairs and is connected to the cable modem. 2nd router is downstairs and acts as "signal booster" for the 1st router. Devices connected to the upstairs router have IP addresses of the form 192.168.1.n Devices connected to the upstairs router have IP addresses of the form 192.168.2.n. I blindly followed instructions from a website to do this set up, just glad it works! Upstairs I have a PC running Win 7 64 bit. Its assigned IP is 192.168.1.7. I have a VNC viewer running on this. Downstairs I have a 2nd PC running Vista 32 Home edition bit that is connected to the 2nd router and has IP Address 192.168.2.114. VNC server is running on this. It's listening on 5900. There is no firewall. When I try to connect to this downstairs PC from upstairs it fails with message "Failed to connect to server". I cannot ping to this either. If I try to connect to this downstairs PC using VNC Viewer from another computer that's connected to the same downstairs router then it works like a charm. So what's the work around if the viewer is on a different "network"? I don't have any problems doing remote desktop connection from the downstairs PC to the upstairs PC even if they are connected to different routers. Router information- Upstairs- ASUS RTN13U, downstairs- DD-WRT v24 RC-5 Thanks! P.S. I posted this on the Ultra VNC forum as well but that doesn't seem to have a lot of activity, so taking the liberty to multipost.

    Read the article

  • Building a small server farm

    - by RayQuang
    Hi, I am planning to set up a Tech startup company that will provide web application solutions. Eventually we hope to diversify into different areas such as possibly social media or other services. For now we plan on running a high demand (from 1000 to 10,000 users in the first year) website running the application. This includes a MySQL database backend, email, and development servers. My question is then, what type of server arrangement will work best, that is ti say should i have a small cluster of ultra high power machines (E.G. Top of the range Xeons, with 12GB RAM) or will it be better to have more less powerful servers load balanced? Should I go for 1 - 2 u servers rack mounted ot would it be beter for it just to be tower servers for maintainability? Finally I would also like to know what kind of Internet and router i would need, I currently have 10mbit down and barely 1 mbit up, but soon our area will have a fiber optic connection with international speeds of up to 25 mbit / sec. Thanks in advance, RayQuang UPDATE: sorry I forgot to mention it, the platform that I will be using is PHP with the APC code cache, Probably running Debian.

    Read the article

  • Hide and Unhide Worksheets and Workbooks in Excel 2007 & 2010

    - by DigitalGeekery
    Hiding worksheets can be a simple way to protect data in Excel, or just a way reduce the clutter of a some tabs. Here are a couple very easy ways to hide and unhide worksheets and workbooks in Excel 2007 / 2010. Hiding a Worksheet Select the Worksheet you’d like to hide by clicking on the tab at the bottom. By holding down the Ctrl key while clicking you can select multiple tabs at one time. On the Home tab, click on Format, which can be found in the Cells group. Under Visibility,  select Hide & Unhide, then Hide Sheet.   You can also simply right-click on the tab, and select Hide.   Your worksheet will no longer be visible, however, the data contained in the worksheet can still be referenced on other worksheets.   Unhide a Worksheet To unhide a worksheet, you just do the opposite. On the Home tab, click on Format in the Cells group and then under Visibility,  select Hide & Unhide, then Unhide Sheet.   Or, you can right-click on any visible tab, and select Unhide.   In the Unhide pop up window, select the worksheet to unhide and click “OK.” Note: Although you can hide multiple sheets at once, you can only unhide one sheet at a time. Very Hidden Mode While hidden mode is nice, it’s not exactly ultra-secure. If you’d like to pump the security up a notch, there is also Very Hidden mode. To access Very Hidden setting, we’ll have to use the built-in Visual Basic Editor by hitting the Alt + F11 keys. Select the worksheet you wish to hide from the dropdown list under Properties or by single clicking the worksheet in the VBAProject window. Next, set the Visible property to  2 – xlSheetVeryHidden. Close out of the Visual Basic Editor when finished.   When the Very Hidden attribute is set on a worksheet, Unhide Sheet is still unavailable from within the Format setting on the Home tab.   To remove the Very Hidden attribute and display the worksheet again, go back into the Visual Basic Editor by hitting Alt + F11 again and setting the Visible property back to –1 – xlSheetVisible.  Close out of the Editor when finished. Hiding a Workbook To hide the entire Workbook, select the View tab, and then click the Hide button. You’ll see the Workbook has disappeared. Unhide a Workbook Select the View tab and click Unhide… … and your Workbook will be visible again.   Just a few simple ways to hide and unhide your Excel worksheets and workbooks. Similar Articles Productive Geek Tips How To Copy Worksheets in Excel 2007 & 2010Add Background Pictures To Excel 2007 WorksheetsMake Row Labels In Excel 2007 Freeze For Easier ReadingImport Microsoft Access Data Into ExcelMagnify Selected Cells In Excel 2007 TouchFreeze Alternative in AutoHotkey The Icy Undertow Desktop Windows Home Server – Backup to LAN The Clear & Clean Desktop Use This Bookmarklet to Easily Get Albums Use AutoHotkey to Assign a Hotkey to a Specific Window Latest Software Reviews Tinyhacker Random Tips DVDFab 6 Revo Uninstaller Pro Registry Mechanic 9 for Windows PC Tools Internet Security Suite 2010 Discover Latest Android Apps On AppBrain The Ultimate Guide For YouTube Lovers Will it Blend? iPad Edition Penolo Lets You Share Sketches On Twitter Visit Woolyss.com for Old School Games, Music and Videos Add a Custom Title in IE using Spybot or Spyware Blaster

    Read the article

  • Fast Data - Big Data's achilles heel

    - by thegreeneman
    At OOW 2013 in Mark Hurd and Thomas Kurian's keynote, they discussed Oracle's Fast Data software solution stack and discussed a number of customers deploying Oracle's Big Data / Fast Data solutions and in particular Oracle's NoSQL Database.  Since that time, there have been a large number of request seeking clarification on how the Fast Data software stack works together to deliver on the promise of real-time Big Data solutions.   Fast Data is a software solution stack that deals with one aspect of Big Data, high velocity.   The software in the Fast Data solution stack involves 3 key pieces and their integration:  Oracle Event Processing, Oracle Coherence, Oracle NoSQL Database.   All three of these technologies address a high throughput, low latency data management requirement.   Oracle Event Processing enables continuous query to filter the Big Data fire hose, enable intelligent chained events to real-time service invocation and augments the data stream to provide Big Data enrichment. Extended SQL syntax allows the definition of sliding windows of time to allow SQL statements to look for triggers on events like breach of weighted moving average on a real-time data stream.    Oracle Coherence is a distributed, grid caching solution which is used to provide very low latency access to cached data when the data is too big to fit into a single process, so it is spread around in a grid architecture to provide memory latency speed access.  It also has some special capabilities to deploy remote behavioral execution for "near data" processing.   The Oracle NoSQL Database is designed to ingest simple key-value data at a controlled throughput rate while providing data redundancy in a cluster to facilitate highly concurrent low latency reads.  For example, when large sensor networks are generating data that need to be captured while analysts are simultaneously extracting the data using range based queries for upstream analytics.  Another example might be storing cookies from user web sessions for ultra low latency user profile management, also leveraging that data using holistic MapReduce operations with your Hadoop cluster to do segmented site analysis.  Understand how NoSQL plays a critical role in Big Data capture and enrichment while simultaneously providing a low latency and scalable data management infrastructure thru clustered, always on, parallel processing in a shared nothing architecture. Learn how easily a NoSQL cluster can be deployed to provide essential services in industry specific Fast Data solutions. See these technologies work together in a demonstration highlighting the salient features of these Fast Data enabling technologies in a location based personalization service. The question then becomes how do these things work together to deliver an end to end Fast Data solution.  The answer is that while different applications will exhibit unique requirements that may drive the need for one or the other of these technologies, often when it comes to Big Data you may need to use them together.   You may have the need for the memory latencies of the Coherence cache, but just have too much data to cache, so you use a combination of Coherence and Oracle NoSQL to handle extreme speed cache overflow and retrieval.   Here is a great reference to how these two technologies are integrated and work together.  Coherence & Oracle NoSQL Database.   On the stream processing side, it is similar as with the Coherence case.  As your sliding windows get larger, holding all the data in the stream can become difficult and out of band data may need to be offloaded into persistent storage.  OEP needs an extreme speed database like Oracle NoSQL Database to help it continue to perform for the real time loop while dealing with persistent spill in the data stream.  Here is a great resource to learn more about how OEP and Oracle NoSQL Database are integrated and work together.  OEP & Oracle NoSQL Database.

    Read the article

  • Async Load JavaScript Files with Callback

    - by Gcoop
    Hi All, I am trying to write an ultra simple solution to load a bunch of JS files asynchronously. I have the following script below so far. However the callback is sometimes called when the scripts aren't actually loaded which causes a variable not found error. If I refresh the page sometimes it just works because I guess the files are coming straight from the cache and thus are there quicker than the callback is called, it's very strange? var Loader = function () { } Loader.prototype = { require: function (scripts, callback) { this.loadCount = 0; this.totalRequired = scripts.length; this.callback = callback; for (var i = 0; i < scripts.length; i++) { this.writeScript(scripts[i]); } }, loaded: function (evt) { this.loadCount++; if (this.loadCount == this.totalRequired && typeof this.callback == 'function') this.callback.call(); }, writeScript: function (src) { var self = this; var s = document.createElement('script'); s.type = "text/javascript"; s.async = true; s.src = src; s.addEventListener('load', function (e) { self.loaded(e); }, false); var head = document.getElementsByTagName('head')[0]; head.appendChild(s); } } Is there anyway to test that a JS file is completely loaded, without putting something in the actual JS file it's self, because I would like to use the same pattern to load libraries out of my control (GMaps etc). Invoking code, just before the tag. var l = new Loader(); l.require([ "ext2.js", "ext1.js"], function() { var config = new MSW.Config(); Refraction.Application().run(MSW.ViewMapper, config); console.log('All Scripts Loaded'); }); Thanks for any help.

    Read the article

  • Search and replace hundreds of strings in tens of thousands of files?

    - by C Johnson
    I am looking into changing the file name of hundreds of files in a (C/C++) project that I work on. The problem is our software has tens of thousands of files that including (i.e. #include) these hundreds of files that will get changed. This looks like a maintenance nightmare. If I do this I will be stuck in Ultra-Edit for weeks, rolling hundreds of regex's by hand like so: ^\#include.*["<\\/]stupid_name.*$ with #include <dir/new_name.h> Such drudgery would be worse than peeling hundreds of potatoes in a sunken submarine in the antarctic with a spoon. I think it would rather be ideal to put the inputs and outputs into a table like so: stupid_name.h <-> <dir/new_name.h> stupid_nameb.h <-> <dir/new_nameb.h> stupid_namec.h <-> <dir/new_namec.h> and feed this into a regular expression engine / tool / app / etc... My Ultimate Question: Is there a tool that will do that? Bonus Question: Is it multi-threaded? I looked at quite a few search and replace topics here on this website, and found lots of standard queries that asked a variant of the following question: standard question: Replace one term in N files. as opposed to: my question: Replace N terms in N files. Thanks in advance for any replies.

    Read the article

  • Conventions for the behavior of double or triple "click to select text" features?

    - by John Sullivan
    Almost any mature program that involves text implements "double click to select the word" and, in some cases, "triple click to select additional stuff like an entire line" as a feature. I find these features useful but they are often inconsistent between programs. Example - some programs' double clicks do not select the ending space after a word, but most do. Some recognize the - character as the end of a word, others do not. SO likes to select the entire paragraph as I write this post when I triple click it, VS web developer 2005 has no triple click support, and ultra-edit 32 will select one line upon triple clicking. We could come up with innumerable inconsistencies about how double and triple click pattern matching is implemented across programs. I am concerned about how to implement this behavior in my program if nobody else has achieved a convention about how the pattern matching should work. My question is, does a convention (conventions? maybe an MS or Linux convention?) exist that dictates how these features are supposed to behave to the end user? What, if any, are they?

    Read the article

  • JBoss Clustered Service that sends emails from txt file

    - by michael lucas
    I need a little push in the right direction. Here's my problem: I have to create an ultra-reliable service that sends email messages to clients whose addresses are stored in txt file on FTP server. Single txt file may contain unlimited number of entries. Most often the file contains about 300,000 entries. Service exposes interface with just two simple methods: TaskHandle sendEmails(String ftpFilePath); ProcessStatus checkProcessStatus(TaskHandle taskHandle); Method sendEmails() returns TaskHandle by which we can ask for ProcessStatus. For such a service to be reliable clustering is necessary. Processing single txt file might take a long time. Restarting one node in a cluster should have no impact on sending emails. We use JBoss AS 4.2.0 which comes with a nice HASingletonController that ensure one instance of service is running at given time. But once a fail-over happens, the second service should continue work from where the first one stopped. How can I share state between nodes in a cluster in such a way that leaves no possibility of sending some emails twice?

    Read the article

  • I read 3 pages of a JQuery book and here's my reaction and question

    - by George
    My jQuery reaction to the language's flexible "selectors" is probably rooted in this experience: I once had managed a project where a developer constructed a web page that was used by users to provide very flexible search parameters for a search screen using dynamic sql string building based on the user's specified search parameter. The resulting queries were usually very complicated and involved joins to many tables. One of the options that the user had was to choose from one of 3 an options. Depending on the user's choice for this option, the resulting SQL would need to query a different set of database columns. For example, if choice option "A" were selected, the resulting database columns queried would be prefixed with "A_"; if option "B" were selected, he resulting database columns queried would be prefixed with "B_" and so on. The developer choice to write all the complete SQL assuming that the user selected, for example, option "A" and therefore first constructed SQLs of this type: SQL = "SELECT A_COL1, A_COL2, A_COL3 FROM TABLE ..." and then after constructing one of a million possible variations on the Query From Hell, did something like this: If UserOption = "B" then SQL = SQL.Replace("A_","B_") 'replace everywhere End if He insisted that this was the easiest was to code it, and while I understood that, I was concerned about maintenance of this code. You see, this worked for a while, but as the search options grew and the database columns evolved, the various "REPLACE small substring" with another small substring had unexpected consequences when applied to an evolving database and new search options. My feeling is that code should be written as much as possible such that you can add to it without fear of breaking what is already there. I feel a better approach, though a bit more work, would have been to write a function to return the appropriate target column based on a common set name and the user selected option. OK, so what does this have to do with jQuery selectors? Are the ultra flexible JQuery selectors kind of like perform a "replace all" on a SQL string? Handy as hell but potentially creating a maintenance nightmare?

    Read the article

  • std::vector elements initializing

    - by Chameleon
    std::vector<int> v1(1000); std::vector<std::vector<int>> v2(1000); std::vector<std::vector<int>::const_iterator> v3(1000); How elements of these 3 vectors initialized? About int, I test it and I saw that all elements become 0. Is this standard? I believed that primitives remain undefined. I create a vector with 300000000 elements, give non-zero values, delete it and recreate it, to avoid OS memory clear for data safety. Elements of recreated vector were 0 too. What about iterator? Is there a initial value (0) for default constructor or initial value remains undefined? When I check this, iterators point to 0, but this can be OS When I create a special object to track constructors, I saw that for first object, vector run the default constructor and for all others it run the copy constructor. Is this standard? Is there a way to completely avoid initialization of elements? Or I must create my own vector? (Oh my God, I always say NOT ANOTHER VECTOR IMPLEMENTATION) I ask because I use ultra huge sparse matrices with parallel processing, so I cannot use push_back() and of course I don't want useless initialization, when later I will change the value.

    Read the article

  • Audio Streaming Latency

    - by killianmcc
    I'm writing a UDP local area network video chat system and have got the video and audio streams working. However I'm experiencing a little latency (about half a second) in the audio and was wondering what codecs would provide the least latency. I'm using NAudio (http://naudio.codeplex.com/) which provides me access to the following codecs for streaming; Speex Narrow Band (VBR) Speex Wide Band (16kHz)(VBR) Speex Ultra Wide Band (32kHz)(VBR) DSP Group TrueSpeech (8.5kbps) GSM 6.10 (13kbps) Microsoft ADPCM (32.8kbps) G.711 a-law (64kbps) G.722 16kHz (64kbps) G.711 mu-law (64kbps) PCM 8kHz 16 bit uncompressed (128kbps) I've tried them out and I'm not noticing much difference. Is there any others that I should download and try to reduce latency? I'm only going to be sending voice over the connection but I'm not really worried about quality or background noises too much. UPDATE I'm sending the audio in blocks like so; waveIn = new WaveIn(); waveIn.BufferMilliseconds = 50; waveIn.DeviceNumber = inputDeviceNumber; waveIn.WaveFormat = codec.RecordFormat; waveIn.DataAvailable += waveIn_DataAvailable; void waveIn_DataAvailable(object sender, WaveInEventArgs e) { if (connected) { byte[] encoded = codec.Encode(e.Buffer, 0, e.BytesRecorded); udpSender.Send(encoded, encoded.Length); } }

    Read the article

  • Set up basic Windows Authentication to connect to SQL Server 2008 from a small, trusted network

    - by Margaret
    I'm guessing that this is documented somewhere on Microsoft's site, but thus far I haven't found it. I'm trying to set up a Windows Server 2008 box to have SQL Server 2008 with Windows Authentication (Mixed Mode, actually, but anyway) for work. We have a number of client machines that will need access to the databases, and I would like to keep configuration as simple as feasible. Here's what I've done so far: Install SQL Server 2008 selecting Mixed Mode Create a new 'Standard' (rather than Administrator) Windows login entitled "UserLogin" (with intent to use it as the access account) Create an SQL Server Login for Server\UserLogin and assign it 'Windows Authentication' Log in as UserLogin, check that I'm able to connect to SQL Server using WIndows Authentication, then log out again Start on the first client (Windows XPSP2, SQL Server 2005): Run C:\WINDOWS\system32\rundll32.exe keymgr.dll, KRShowKeyMgr Click "Add", enter the server name in the box, Server\UserLogin in the Username, and UserLogin's password in the Password field. Click "Ok" then "Close" Attempt to access SQL Server 2005 using Windows authentication. Succeed. Confetti! Start on the second client (Windows 7, SQL Server 2008): Run C:\WINDOWS\system32\rundll32.exe keymgr.dll, KRShowKeyMgr Click "Add", enter the server name in the box, Server\UserLogin in the Username, and UserLogin's password in the Password field. Click "Ok" then "Close" Attempt to access SQL Server 2008 using Windows authentication. Receive an error "Login failed. The login is from an untrusted domain and cannot be used with Windows authentication" Assume that this translates to "You can't have two connections from the same account" (Yes, I know that doesn't make sense, but I'm a bit like that) Go back to the server, create a second Windows account, give it SQL Server rights. Go back to the second client, create a new passkey for the second login, try logging in again. Continue to receive the same error. Is this all overly complex and there's an easy way to do what I'm trying to accomplish? Or am I missing some ultra-obvious step that would make everything behave as desired? Most of the stuff that's coming up when I try to Google seems to be along the lines of "My ASP.NET application isn't working!", which obviously isn't all that much use.

    Read the article

  • Connecting a 2560x1440 display to a laptop?

    - by tjollans
    Having read Jeff Atwood's blog post on Korean 27" IPS LCDs, I've been wondering to what extent these are useful in a notebook + large display situation. I own a Lenovo Thinkpad Edge E320 with 2nd gen. integrated Intel graphics. According to the spec from Intel, this should support HDMI version 1.4, and, using DisplayPort, resolutions up to 2560x1600. HDMI version 1.4 supports resolutions up to 4096×2160, however, according to c't (German), the HDMI interface used with Intel chips only supports 1920x1200. The same goes for the DVI output - dual-link DVI-D, apparently, is not supported by Intel. It would appear that my laptop cannot digitally drive this kind of resolution. Now what about other laptops? According to the article in c't above, AMD's integrated graphics chips have the same limitation as Intel's. NVIDIA graphics cards, apparently, only offer resolutions up to 1900x1200 over HDMI out of the box, but it's possible, when using Linux at least, to trick the driver into enabling higher resolutions. Is this still true? What's the situation on Windows and OSX? I found no information on whether discrete AMD chips support ultra-high resolutions over HDMI. Owners of laptops with (Mini) DisplayPort / Thunderbolt won't have any issues with displays this large, but if you're planning to go for a display with dual-link DVI-D input only (like the Korean ones), you're going to need an adapter, which will set you back something like €70-€100 (since the protocols are incompatible). The big question mark in this equation is VGA: a lot of laptops have it, and I don't see any reason to think this resolution is not supported by the hardware (an oft-quoted figure appears to be 2048x1536@75Hz, so 2560x1440@60Hz should be possible, right?), but are the drivers likely to cause problems? Perhaps more critically, you'd need a VGA to dual-link DVI-D adapter that converts analog to digital signals. Do these exist? How good are they? How expensive are they? Is there a performance penalty involved? Please correct me if I'm wrong on any points. In summary, what are the requirements on a laptop to drive an external LCD at 2560x1440, in particular one that supports dual-link DVI-D only, and what tools and adapters can be used to lower the bar?

    Read the article

  • HttpWebRequest and Ignoring SSL Certificate Errors

    - by Rick Strahl
    Man I can't believe this. I'm still mucking around with OFX servers and it drives me absolutely crazy how some these servers are just so unbelievably misconfigured. I've recently hit three different 3 major brokerages which fail HTTP validation with bad or corrupt certificates at least according to the .NET WebRequest class. What's somewhat odd here though is that WinInet seems to find no issue with these servers - it's only .NET's Http client that's ultra finicky. So the question then becomes how do you tell HttpWebRequest to ignore certificate errors? In WinInet there used to be a host of flags to do this, but it's not quite so easy with WebRequest. Basically you need to configure the CertificatePolicy on the ServicePointManager by creating a custom policy. Not exactly trivial. Here's the code to hook it up: public bool CreateWebRequestObject(string Url) {    try     {        this.WebRequest =  (HttpWebRequest) System.Net.WebRequest.Create(Url);         if (this.IgnoreCertificateErrors)            ServicePointManager.CertificatePolicy = delegate { return true; };}One thing to watch out for is that this an application global setting. There's one global ServicePointManager and once you set this value any subsequent requests will inherit this policy as well, which may or may not be what you want. So it's probably a good idea to set the policy when the app starts and leave it be - otherwise you may run into odd behavior in some situations especially in multi-thread situations.Another way to deal with this is in you application .config file. Normal 0 false false false EN-US X-NONE X-NONE /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin-top:0in; mso-para-margin-right:0in; mso-para-margin-bottom:10.0pt; mso-para-margin-left:0in; line-height:115%; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri","sans-serif"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin; mso-bidi-font-family:"Times New Roman"; mso-bidi-theme-font:minor-bidi;} <configuration>   <system.net>     <settings>       <servicePointManager           checkCertificateName="false"           checkCertificateRevocationList="false"                />     </settings>   </system.net> </configuration> This seems to work most of the time, although I've seen some situations where it doesn't, but where the code implementation works which is frustrating. The .config settings aren't as inclusive as the programmatic code that can ignore any and all cert errors - shrug. Anyway, the code approach got me past the stopper issue. It still amazes me that theses OFX servers even require this. After all this is financial data we're talking about here. The last thing I want to do is disable extra checks on the certificates. Well I guess I shouldn't be surprised - these are the same companies that apparently don't believe in XML enough to generate valid XML (or even valid SGML for that matter)...© Rick Strahl, West Wind Technologies, 2005-2011Posted in .NET  CSharp  HTTP  

    Read the article

  • Weekend With #iPad

    - by andrewbrust
    Saturday morning, I got up, got dressed and took a 7-minute walk up to the Apple Store in New York’s Meatpacking District to pick up my reserved iPad.  This precinct, which borders Greenwich Village (where I live and grew up) was, when I was a kid, a very industrial and smelly neighborhood during the day  and a rough neighborhood at night.  So imagine my sense of irony as I walked up Hudson Street towards 14th Street, to go wait in line with a bunch of hipsters to buy an iPad on launch day. Numerous blue T-shirt-clad Apple store workers were on hand to check people in to the line specifically identified for people who had reserved an iPad.  Others workers passed out water and all of them, I kid you not, applauded people as they got their chance to go into the store and buy their devices.  They also cheered people and yelled “congratulations” as they left.  The event had all the charm of a mass wedding officiated by Reverend Sung Myung Moon.  Once inside, a nice dude named Trey, with lots of tattoos on his calves, helped me and I acquired my device in short order.  Another guy helped me activate the device, which was comical, because that has to be done through iTunes, which I hadn’t logged into in a while. Turns out my user id was my email address from the company I sold 5 1/2 years ago.  Who knew?  Regardless, I go the device working, packed up and left the store, shuddering as I was cheered and congratulated.  By this time (about 10:30am) the line for reserved units and even walk-ins, was gone.  The iPhone launch this was not. As much as I detested the Apple Store experience, I must say the device is really nice.  the screen is bright, the colors are bold, and the experience is ultra-smooth.  I quickly tested Safari, YouTube, Google Maps, and then installed a few apps, including the New York Times Editors’ Choice and a couple of Twitter clients. Some initial raves: Google Maps and Street View on the iPad is just amazing.  The screen is full-size like a PC or Mac, but it’s right in front of you and responding to taps and flicks and pinches and it’s really engulfing.  Video and photos are really nice on this device, despite the fact that 16:9 and anamorphic aspect ration content is letter boxed.  It still looks amazing.  And apps that are designed especially for the iPad, including The Weather Channel and Gilt and Kayak just look stunning.  The richness, the friendly layout, the finger-friendly UIs, and the satisfaction of not having a keyboard between you and the information you’re managing, while you sit on a couch or an easy chair, is just really a beautiful thing.  The mere experience of seeing these apps’ splash screens causes a shiver and Goosebumps.  Truly.  The iPad is not a desktop machine, and it’s not pocket device.  That doesn’t mean it’s useless though.  It’s the perfect “couchtop” computer. Now some downsides: the WiFi radio seems a bit flakey.  More than a few times, I have had to toggle the WiFi off and back on to get it to connect properly.  Worse yet, the iPad is totally bamboozled by the fact that I have four WiFi access points in my house, each with the same SSID.  My laptops are smart enough to roam from one to the other, but the iPad seems to maintain an affinity for the downstairs access point, even if I’m turning it on two flights up.  Telling the iPad to “forget” my WiFi network and then re-associate with it doesn’t help. More downers: as you might expect, there are far more applications developed for the iPhone than the iPad.  And although iPhone apps run on the iPad, that provides about the same experience as watching standard def on a big HD flat panel, complete with the lousy choice of thick black borders or zooming the picture in to fill the screen.  And speaking of iPhone Apps, I can’t get the Sonos one to work.  Ideally, they’d have a dedicated iPad app and it would work on the first try.  And the iPad is just as bad as any netbook when it comes to being a magnet for fingerprints.  The lack of multi-tasking is quite painful too – truly, I don’t mind if only one app can be active at once, but the lack of ability to switch between apps, and the requirement to return to the home screen and re-launch a previous app to switch back, is already old and I’ve had the thing less than 48 hours. These are just initial impressions.  I’ll have a fuller analysis soon, after I’ve had some more break-in time with my new toy.  I’ll be thinking not just about the iPad and iPhone but also about Android, the 2.1 update for which was pushed to my Droid today, and Windows Phone 7, whose “hub” concept I now understand the value of.  This has been a great year for alternative computing devices, and I see no net downside for Apple, Google or Microsoft.  Exciting times.

    Read the article

  • How to Buy an SD Card: Speed Classes, Sizes, and Capacities Explained

    - by Chris Hoffman
    Memory cards are used in digital cameras, music players, smartphones, tablets, and even laptops. But not all SD cards are created equal — there are different speed classes, physical sizes, and capacities to consider. Different devices require different types of SD cards. Here are the differences you’ll need to keep in mind when picking out the right SD card for your device. Speed Class In a nutshell, not all SD cards offer the same speeds. This matters for some tasks more than it matters for others. For example, if you’re a professional photographer taking photos in rapid succession on a DSLR camera saving them in high-resolution RAW format, you’ll want a fast SD card so your camera can save them as fast as possible. A fast SD card is also important if you want to record high-resolution video and save it directly to the SD card. If you’re just taking a few photos on a typical consumer camera or you’re just using an SD card to store some media files on your smartphone, the speed isn’t as important. Manufacturers use “speed classes” to measure an SD card’s speed. The SD Association that defines the SD card standard doesn’t actually define the exact speeds associated with these classes, but they do provide guidelines. There are four different speed classes — 10, 8, 4, and 2. 10 is the fastest, while 2 is the slowest. Class 2 is suitable for standard definition video recording, while classes 4 and 6 are suitable for high-definition video recording. Class 10 is suitable for “full HD video recording” and “HD still consecutive recording.” There are also two Ultra High Speed (UHS) speed classes, but they’re more expensive and are designed for professional use. UHS cards are designed for devices that support UHS. Here are the associated logos, in order from slowest to fastest:       You’ll probably be okay with a class 4 or 6 card for typical use in a digital camera, smartphone, or tablet. Class 10 cards are ideal if you’re shooting high-resolution videos or RAW photos. Class 2 cards are a bit on the slow side these days, so you may want to avoid them for all but the cheapest digital cameras. Even a cheap smartphone can record HD video, after all. An SD card’s speed class is identified on the SD card itself. You’ll also see the speed class on the online store listing or on the card’s packaging when purchasing it. For example, in the below photo, the middle SD card is speed class 4, while the two other cards are speed class 6. If you see no speed class symbol, you have a class 0 SD card. These cards were designed and produced before the speed class rating system was introduced. They may be slower than even a class 2 card. Physical Size Different devices use different sizes of SD cards. You’ll find standard-size CD cards, miniSD cards, and microSD cards. Standard SD cards are the largest, although they’re still very small. They measure 32x24x2.1 mm and weigh just two grams. Most consumer digital cameras for sale today still use standard SD cards. They have the standard “cut corner”  design. miniSD cards are smaller than standard SD cards, measuring 21.5x20x1.4 mm and weighing about 0.8 grams. This is the least common size today. miniSD cards were designed to be especially small for mobile phones, but we now have a smaller size. microSD cards are the smallest size of SD card, measuring 15x11x1 mm and weighing just 0.25 grams. These cards are used in most cell phones and smartphones that support SD cards. They’re also used in many other devices, such as tablets. SD cards will only fit into marching slots. You can’t plug a microSD card into a standard SD card slot — it won’t fit. However, you can purchase an adapter that allows you to plug a smaller SD card into a larger SD card’s form and fit it into the appropriate slot. Capacity Like USB flash drives, hard drives, solid-state drives, and other storage media, different SD cards can have different amounts of storage. But the differences between SD card capacities don’t stop there. Standard SDSC (SD) cards are 1 MB to 2 GB in size, or perhaps 4 GB in size — although 4 GB is non-standard. The SDHC standard was created later, and allows cards 2 GB to 32 GB in size. SDXC is a more recent standard that allows cards 32 GB to 2 TB in size. You’ll need a device that supports SDHC or SDXC cards to use them. At this point, the vast majority of devices should support SDHC. In fact, the SD cards you have are probably SDHC cards. SDXC is newer and less common. When buying an SD card, you’ll need to buy the right speed class, size, and capacity for your needs. Be sure to check what your device supports and consider what speed and capacity you’ll actually need. Image Credit: Ryosuke SEKIDO on Flickr, Clive Darra on Flickr, Steven Depolo on Flickr

    Read the article

  • ACORD LOMA Session Highlights Policy Administration Trends

    - by [email protected]
    Helen Pitts, senior product marketing manager for Oracle Insurance, attended and is blogging from the ACORD LOMA Insurance Forum this week. Above: Paul Vancheri, Chief Information Officer, Fidelity Investments Life Insurance Company. Vancheri gave a presentation during the ACORD LOMA Insurance Systems Forum about the key elements of modern policy administration systems and how insurers can mitigate risk during legacy system migrations to safely introduce new technologies. When I had a few particularly challenging honors courses in college my father, a long-time technology industry veteran, used to say, "If you don't know how to do something go ask the experts. Find someone who has been there and done that, don't be afraid to ask the tough questions, and apply and build upon what you learn." (Actually he still offers this same advice today.) That's probably why my favorite sessions at industry events, like the ACORD LOMA Insurance Forum this week, are those that include insight on industry trends and case studies from carriers who share their experiences and offer best practices based upon their own lessons learned. I had the opportunity to attend a particularly insightful session Wednesday as Craig Weber, senior vice president of Celent's Insurance practice, and Paul Vancheri, CIO of Fidelity Life Investments, presented, "Managing the Dynamic Insurance Landscape: Enabling Growth and Profitability with a Modern Policy Administration System." Policy Administration Trends Growing the business is the top issue when it comes to IT among both life and annuity and property and casualty carriers according to Weber. To drive growth and capture market share from competitors, carriers are looking to modernize their core insurance systems, with 65 percent of those CIOs participating in recent Celent research citing plans to replace their policy administration systems. Weber noted that there has been continued focus and investment, particularly in the last three years, by software and technology vendors to offer modern, rules-based, configurable policy administration solutions. He added that these solutions are continuing to evolve with the ongoing aim of helping carriers rapidly meet shifting business needs--whether it is to launch new products to market faster than the competition, adapt existing products to meet shifting consumer and /or regulatory demands, or to exit unprofitable markets. He closed by noting the top four trends for policy administration either in the process of being adopted today or on the not-so-distant horizon for the future: Underwriting and service desktops New business automation Convergence of ultra-configurable and domain content-rich systems Better usability and screen design Mitigating the Risk When Making the Decision to Modernize Third-party analyst research from advisory firms like Celent was a key part of the due diligence process for Fidelity as it sought a replacement for its legacy policy administration system back in 2005, according to Vancheri. The company's business opportunities were outrunning system capability. Its legacy system had not been upgraded in several years and was deficient from a functionality and currency standpoint. This was constraining the carrier's ability to rapidly configure and bring new and complex products to market. The company sought a new, modern policy administration system, one that would enable it to keep pace with rapid and often unexpected industry changes and ahead of the competition. A cross-functional team that included representatives from finance, actuarial, operations, client services and IT conducted an extensive selection process. This process included deep documentation review, pilot evaluations, demonstrations of required functionality and complex problem-solving, infrastructure integration capability, and the ability to meet the company's desired cost model. The company ultimately selected an adaptive policy administration system that met its requirements to: Deliver ease of use - eliminating paper and rework, while easing the burden on representatives to sell and service annuities Provide customer parity - offering Web-based capabilities in alignment with the company's focus on delivering a consistent customer experience across its business Deliver scalability, efficiency - enabling automation, while simplifying and standardizing systems across its technology stack Offer desired functionality - supporting Fidelity's product configuration / rules management philosophy, focus on customer service and technology upgrade requirements Meet cost requirements - including implementation, professional services and licenses fees and ongoing maintenance Deliver upon business requirements - enabling the ability to drive time to market for new products and flexibility to make changes Best Practices for Addressing Implementation Challenges Based upon lessons learned during the company's implementation, Vancheri advised carriers to evaluate staffing capabilities and cultural impacts, review business requirements to avoid rebuilding legacy processes, factor in dependent systems, and review policies and practices to secure customer data. His formula for success: upfront planning + clear requirements = precision execution. Achieving a Return on Investment Vancheri said the decision to replace their legacy policy administration system and deploy a modern, rules-based system--before the economic downturn occurred--has been integral in helping the company adapt to shifting market conditions, while enabling growth in its direct channel sales of variable annuities. Since deploying its new policy admin system, the company has reduced its average time to market for new products from 12-15 months to 4.5 months. The company has since migrated its other products to the new system and retired its legacy system, significantly decreasing its overall product development cycle. From a processing standpoint Vancheri noted the company has achieved gains in automation, information, and ease of use, resulting in improved real-time data edits, controls for better quality, and tax handling capability. Plus, with by having only one platform to manage, the company has simplified its IT environment and is well positioned to deliver system enhancements for greater efficiencies. Commitment to Continuing the Investment In the short and longer term future Vancheri said the company plans to enhance business functionality to support money movement, wire automation, divorce processing on payout contracts and cost-based tracking improvements. It also plans to continue system upgrades to remain current as well as focus on further reducing cycle time, driving down maintenance costs, and integrating with other products. Helen Pitts is senior product marketing manager for Oracle Insurance focused on life/annuities and enterprise document automation.

    Read the article

  • How do I prove or disprove "god" objects are wrong?

    - by honestduane
    Problem Summary: Long story short, I inherited a code base and an development team I am not allowed to replace and the use of God Objects is a big issue. Going forward, I want to have us re-factor things but I am getting push-back from the teams who want to do everything with God Objects "because its easier" and this means I would not be allowed to re-factor. I pushed back citing my years of dev experience, that I'm the new boss who was hired to know these things, etc, and so did the third party offshore companies account sales rep, and this is now at the executive level and my meeting is tomorrow and I want to go in with a lot of technical ammo to advocate best practices because I feel it will be cheaper in the long run (And I personally feel that is what the third party is worried about) for the company. My issue is from a technical level, I know its good long term but I'm having trouble with the ultra short term and 6 months term, and while its something I "know" I cant prove it with references and cited resources outside of one person (Robert C. Martin, aka Uncle Bob), as that is what I am being asked to do as I have been told having data from one person and only one person (Robert C Martin) is not good enough of an argument. Question: What are some resources I can cite directly (Title, year published, page number, quote) by well known experts in the field that explicitly say this use of "God" Objects/Classes/Systems is bad (or good, since we are looking for the most technically valid solution)? Research I have already done: I have a number of books here and I have searched their indexes for the use of the words "god object" and "god class". I found that oddly its almost never used and the copy of the GoF book I have for example, never uses it (At least according to the index in front of me) but I have found it in 2 books per the below, but I want more I can use. I checked the Wikipedia page for "God Object" and its currently a stub with little reference links so although I personally agree with that it says, It doesn't have much I can use in an environment where personal experience is not considered valid. The book cited is also considered too old to be valid by the people I am debating these technical points with as the argument they are making is that "it was once thought to be bad but nobody could prove it, and now modern software says "god" objects are good to use". I personally believe that this statement is incorrect, but I want to prove the truth, whatever it is. In Robert C Martin's "Agile Principles, Patterns, and Practices in C#" (ISBN: 0-13-185725-8, hardcover) where on page 266 it states "Everybody knows that god classes are a bad idea. We don't want to concentrate all the intelligence of a system into a single object or a single function. One of the goals of OOD is the partitioning and distribution of behavior into many classes and many function." -- And then goes on to say sometimes its better to use God Classes anyway sometimes (Citing micro-controllers as an example). In Robert C Martin's "Clean Code: A Handbook of Agile Software Craftsmanship" page 136 (And only this page) talks about the "God class" and calls it out as a prime example of a violation of the "classes should be small" rule he uses to promote the Single Responsibility Principle" starting on on page 138. The problem I have is all my references and citations come from the same person (Robert C. Martin), and am from the same single person/source. I am being told that because he is just one guy, my desire to not use "God Classes" is invalid and not accepted as a standard best practice in the software industry. Is this true? Am I doing things wrong from a technical perspective by trying to keep to the teaching of Uncle Bob? God Objects and Object Oriented Programming and Design: The more I think of this the more I think this is more something you learn when you study OOP and its never explicitly called out; Its implicit to good design is my thinking (Feel free to correct me, please, as I want to learn), The problem is I "know" this, but but not everybody does, so in this case its not considered a valid argument because I am effectively calling it out as universal truth when in fact most people are statistically ignorant of it since statistically most people are not programmers. Conclusion: I am at a loss on what to search for to get the best additional results to cite, since they are making a technical claim and I want to know the truth and be able to prove it with citations like a real engineer/scientist, even if I am biased against god objects due to my personal experience with code that used them. Any assistance or citations would be deeply appreciated.

    Read the article

  • Unexpected advantage of Engineered Systems

    - by user12244672
    It's not surprising that Engineered Systems accelerate the debugging and resolution of customer issues. But what has surprised me is just how much faster issue resolution is with Engineered Systems such as SPARC SuperCluster. These are powerful, complex, systems used by customers wanting extreme database performance, app performance, and cost saving server consolidation. A SPARC SuperCluster consists or 2 or 4 powerful T4-4 compute nodes, 3 or 6 extreme performance Exadata Storage Cells, a ZFS Storage Appliance 7320 for general purpose storage, and ultra fast Infiniband switches.  Each with its own firmware. It runs Solaris 11, Solaris 10, 11gR2, LDoms virtualization, and Zones virtualization on the T4-4 compute nodes, a modified version of Solaris 11 in the ZFS Storage Appliance, a modified and highly tuned version of Oracle Linux running Exadata software on the Storage Cells, another Linux derivative in the Infiniband switches, etc. It has an Infiniband data network between the components, a 10Gb data network to the outside world, and a 1Gb management network. And customers can run whatever middleware and apps they want on it, clustered in whatever way they want. In one word, powerful.  In another, complex. The system is highly Engineered.  But it's designed to run general purpose applications. That is, the physical components, configuration, cabling, virtualization technologies, switches, firmware, Operating System versions, network protocols, tunables, etc. are all preset for optimum performance and robustness. That improves the customer experience as what the customer runs leverages our technical know-how and best practices and is what we've tested intensely within Oracle. It should also make debugging easier by fixing a large number of variables which would otherwise be in play if a customer or Systems Integrator had assembled such a complex system themselves from the constituent components.  For example, there's myriad network protocols which could be used with Infiniband.  Myriad ways the components could be interconnected, myriad tunable settings, etc. But what has really surprised me - and I've been working in this area for 15 years now - is just how much easier and faster Engineered Systems have made debugging and issue resolution. All those error opportunities for sub-optimal cabling, unusual network protocols, sub-optimal deployment of virtualization technologies, issues with 3rd party storage, issues with 3rd party multi-pathing products, etc., are simply taken out of the equation. All those error opportunities for making an issue unique to a particular set-up, the "why aren't we seeing this on any other system ?" type questions, the doubts, just go away when we or a customer discover an issue on an Engineered System. It enables a really honed response, getting to the root cause much, much faster than would otherwise be the case. Here's a couple of examples from the last month, one found in-house by my team, one found by a customer: Example 1: We found a node eviction issue running 11gR2 with Solaris 11 SRU 12 under extreme load on what we call our ExaLego test system (mimics an Exadata / SuperCluster 11gR2 Exadata Storage Cell set-up).  We quickly established that an enhancement in SRU12 enabled an 11gR2 process to query Infiniband's Subnet Manager, replacing a fallback mechanism it had used previously.  Under abnormally heavy load, the query could return results which were misinterpreted resulting in node eviction.  In several daily joint debugging sessions between the Solaris, Infiniband, and 11gR2 teams, the issue was fully root caused, evaluated, and a fix agreed upon.  That fix went back into all Solaris releases the following Monday.  From initial issue discovery to the fix being put back into all Solaris releases was just 10 days. Example 2: A customer reported sporadic performance degradation.  The reasons were unclear and the information sparse.  The SPARC SuperCluster Engineered Systems support teams which comprises both SPARC/Solaris and Database/Exadata experts worked to root cause the issue.  A number of contributing factors were discovered, including tunable parameters.  An intense collaborative investigation between the engineering teams identified the root cause to a CPU bound networking thread which was being starved of CPU cycles under extreme load.  Workarounds were identified.  Modifications have been put back into 11gR2 to alleviate the issue and a development project already underway within Solaris has been sped up to provide the final resolution on the Solaris side.  The fixed SPARC SuperCluster configuration greatly aided issue reproduction and dramatically sped up root cause analysis, allowing the correct workarounds and fixes to be identified, prioritized, and implemented.  The customer is now extremely happy with performance and robustness.  Since the configuration is common to other customers, the lessons learned are being proactively rolled out to other customers and incorporated into the installation procedures for future customers.  This effectively acts as a turbo-boost to performance and reliability for all SPARC SuperCluster customers.  If this had occurred in a "home grown" system of this complexity, I expect it would have taken at least 6 months to get to the bottom of the issue.  But because it was an Engineered System, known, understood, and qualified by both the Solaris and Database teams, we were able to collaborate closely to identify cause and effect and expedite a solution for the customer.  That is a key advantage of Engineered Systems which should not be underestimated.  Indeed, the initial issue mitigation on the Database side followed by final fix on the Solaris side, highlights the high degree of collaboration and excellent teamwork between the Oracle engineering teams.  It's a compelling advantage of the integrated Oracle Red Stack in general and Engineered Systems in particular.

    Read the article

  • How can I read individual lines of a CSV file into a string array, to then be selectively displayed

    - by Ryan
    I need your help, guys! :| I've got myself a CSV file with the following contents: 1,The Compact,1.8GHz,1024MB,160GB,440 2,The Medium,2.4GHz,1024MB,180GB,500 3,The Workhorse,2.4GHz,2048MB,220GB,650 It's a list of computer systems, basically, that the user can purchase. I need to read this file, line-by-line, into an array. Let's call this array csvline(). The first line of the text file would stored in csvline(0). Line two would be stored in csvline(1). And so on. (I've started with zero because that's where VB starts its arrays). A drop-down list would then enable the user to select 1, 2 or 3 (or however many lines/systems are stored in the file). Upon selecting a number - say, 1 - csvline(0) would be displayed inside a textbox (textbox1, let's say). If 2 was selected, csvline(1) would be displayed, and so on. It's not the formatting I need help with, though; that's the easy part. I just need someone to help teach me how to read a CSV file line-by-line, putting each line into a string array - csvlines(count) - then increment count by one so that the next line is read into another slot. So far, I've been able to paste the numbers of each system into an combobox: Using csvfileparser As New Microsoft.VisualBasic.FileIO.TextFieldParser _ ("F:\folder\programname\programname\bin\Debug\systems.csv") Dim csvalue As String() csvfileparser.TextFieldType = Microsoft.VisualBasic.FileIO.FieldType.Delimited csvfileparser.Delimiters = New String() {","} While Not csvfileparser.EndOfData csvalue = csvfileparser.ReadFields() combobox1.Items.Add(String.Format("{1}{0}", _ Environment.NewLine, _ csvalue(0))) End While End Using But this only selects individual values. I need to figure out how selecting one of these numbers in the combobox can trigger textbox1 to be appended with just that line (I can handle the formatting, using the string.format stuff). If I try to do this using csvalue = csvtranslator.ReadLine , I get the following error message: "Error 1 Value of type 'String' cannot be converted to '1-dimensional array of String'." If I then put it as an array, ie: csvalue() = csvtranslator.ReadLine , I then get a different error message: "Error 1 Number of indices is less than the number of dimensions of the indexed array." What's the knack, guys? I've spent hours trying to figure this out. Please go easy on me - and keep any responses ultra-simple for my newbie brain - I'm very new to all this programming malarkey and just starting out! :)

    Read the article

< Previous Page | 4 5 6 7 8 9 10  | Next Page >