Search Results

Search found 2313 results on 93 pages for 'twice'.

Page 83/93 | < Previous Page | 79 80 81 82 83 84 85 86 87 88 89 90  | Next Page >

  • Copies of GameScene created when called additional times

    - by Orin MacGregor
    I have a game with a level select managed by a SceneManager, which basically just uses ReplaceScene. The first time I load a level everything works fine. On subsequent calls, for example: completing the level and continuing to the next, things blow up. The level loads fine, but when I try to pan the map or try to move the player the game crashes. Debugging through I found that there are multiple occurrences of self and related children like player and mapLayer. As a test, I put this code in my ccTouchesBegan: NSLog(@"test %i", [self retainCount]); The first time a level is loaded, it gives: test 2 The second time I load a level it gives: test 2 test 1 as in it spits out both values by looping through twice, not just appending an output to the last. It continues with this pattern for each subsequent load. So the third time will give 2 1 1. Particular code that causes the game to crash involve calling _tileMap.tileSize because there is a second GameScene with a tileMap that was supposedly destroyed, so it has tileSize and mapSize of 0. I noticed dealloc doesn't really ever get called, so I tried to manage some things with -(void) onExit -(void) onExit { [self unscheduleAllSelectors]; [_player stopAllActions]; //stop any animations just in case. normally handled in ccTouchesEnded [self removeAllChildrenWithCleanup:YES]; } I never replace the GameScene while I'm in a GameScene; if the level is completed it goes to a GameOver scene, or I use a back button that goes to the LevelSelect scene. This is [the relevant parts of] my init, in case something like the adding of children matters: -(id) init { _mapLayer = [CCLayer node]; //load data for level GameData *gameData = [GameDataParser loadData]; int selectedChapter = gameData.selectedChapter; int selectedLevel = gameData.selectedLevel; Levels *chapterLevels = [LevelParser loadLevelsForChapter:selectedChapter]; //loop until we get selected level, then do stuff for (Level *level in chapterLevels.levels) { if (level.number == selectedLevel) { //load the level map _tileMap = [CCTMXTiledMap tiledMapWithTMXFile:level.file]; } } _background = [_tileMap layerNamed:@"Background"]; _foreground = [_tileMap layerNamed:@"Foreground"]; _meta = [_tileMap layerNamed:@"Meta"]; _meta.visible = NO; //initialize Spawn Point object and place player there CCTMXObjectGroup *objects = [_tileMap objectGroupNamed:@"Objects"]; NSAssert(objects != nil, @"'Objects' object group not found"); NSMutableDictionary *spawnPoint = [objects objectNamed:@"SpawnPoint"]; NSAssert(spawnPoint != nil, @"SpawnPoint object not found"); int x = [[spawnPoint valueForKey:@"x"] intValue] / retinaScaling; int y = [[spawnPoint valueForKey:@"y"] intValue] / retinaScaling; //setup animations [[CCSpriteFrameCache sharedSpriteFrameCache] addSpriteFramesWithFile:@"MouseRightAnim_24x21.plist"]; CCSpriteBatchNode *spriteSheet = [CCSpriteBatchNode batchNodeWithFile:@"MouseRightAnim_24x21.png"]; [_mapLayer addChild:spriteSheet z:1]; NSMutableArray *rightAnimFrames = [NSMutableArray array]; for(int i = 1; i <= 3; ++i) { [rightAnimFrames addObject: [[CCSpriteFrameCache sharedSpriteFrameCache] spriteFrameByName: [NSString stringWithFormat:@"MouseRight%d_24x21.png", i]]]; } CCAnimation *rightAnim = [CCAnimation animationWithSpriteFrames:rightAnimFrames delay:0.1f]; self.player = [CCSprite spriteWithSpriteFrameName:@"MouseRight2_24x21.png"]; _player.position = ccp(x, y); self.rightAction = [CCRepeatForever actionWithAction:[CCAnimate actionWithAnimation:rightAnim]]; rightAnim.restoreOriginalFrame = NO; [spriteSheet addChild:_player]; //get map size in pixels mapHeight = _tileMap.contentSize.height; mapWidth = _tileMap.contentSize.width; //setup defaults //this value works well for the calculation later, trial and error really distance = 150; lastGoodDistance = 150; mapScale = 1; [self setViewpointCenter:_player.position]; [_mapLayer addChild:_tileMap]; [self addChild:_mapLayer z:-1]; self.isTouchEnabled = YES; } return self; } And here's the SceneManager code for replacing scenes: +(void) goGameScene { CCLayer *gameLayer = [GameScene node]; [SceneManager go:gameLayer:[GameHUD node]]; } //this is what every call looks like besides the GameScene one above +(void) goLevelSelect { [SceneManager go:[LevelSelect node]:nil]; } +(void) go:(CCLayer *)layer: (CCLayer *)hudLayer { CCDirector *director = [CCDirector sharedDirector]; CCScene *newScene = [SceneManager wrap:layer:hudLayer]; if ([director runningScene]) { [director replaceScene:newScene]; } else { [director runWithScene:newScene]; } } +(CCScene *) wrap:(CCLayer *)layer: (CCLayer *)hudLayer { CCScene *newScene = [CCScene node]; [newScene addChild: layer]; if (hudLayer != nil) { [newScene addChild: hudLayer z:1]; } return newScene; } Any ideas why I'm getting these fatal artifacts? I'm hoping this isn't considered too localized since it basically combines 3 tutorials that anyone could end up following. (Ray Wenderlich Animations, Tim Roadley Scene Manager, Pan and Zoom with Tiled Maps.

    Read the article

  • Bug with asp.net mvc2, collection and ValidationMessageFor ?

    - by Rafael Mueller
    I'm with a really weird bug with asp.net mvc2 (rtm) and ValidationMessageFor. The example below throws a System.Collections.Generic.KeyNotFoundException on Response.Write(Html.ValidationMessageFor(n = n[index].Name)); Any ideas why thats happening? I'm accessing the same dictionary twice before, but it only throws the error on ValidationMessageFor, any thoughts? Here's the code. public class Parent { public IList<Child> Childrens { get; set; } [Required] public string Name { get; set; } } public class Child { [Required] public string Name { get; set; } } The controller public class ParentController : Controller { public ActionResult Create() { var parent = new Parent { Name = "Parent" }; parent.Childrens = new List<Child> { new Child(), new Child(), new Child() }; return View(parent); } } The view (Create.aspx) <%@ Page Title="" Language="C#" MasterPageFile="~/Views/Shared/Site.Master" Inherits="System.Web.Mvc.ViewPage<Parent>" %> <%@ Import Namespace="BugAspNetMVC" %> <asp:Content ID="Content2" ContentPlaceHolderID="MainContent" runat="server"> <%Html.EnableClientValidation(); %> <% using (Html.BeginForm()) {%> <%=Html.LabelFor(p => p.Name)%> <%=Html.TextBoxFor(p => p.Name)%> <%=Html.ValidationMessageFor(p => p.Name)%> <%Html.RenderPartial("Childrens", Model.Childrens); %> <%} %> </asp:Content> And the partial view (Childrens.ascx) <%@ Control Language="C#" Inherits="System.Web.Mvc.ViewUserControl<IList<Child>>" %> <%@ Import Namespace="BugAspNetMVC"%> <% for (int i = 0; i < Model.Count; i++) { var index = i; Response.Write(Html.LabelFor(n => n[index].Name)); Response.Write(Html.TextBoxFor(n => n[index].Name)); Response.Write(Html.ValidationMessageFor(n => n[index].Name)); } %>

    Read the article

  • Mac - Flash file not loaded in independent flash player

    - by Mugdha
    Hi, I am working on an independent application to play flash files on Mac. I have already done the same for Linux, and it works flawlessly but on mac for some reason flash is not drawing to my window. It is not throwing any kind of error too. I am using Flash player 10, that would mean that I am using the Core Graphics drawing model. I am able to send mouse events to flash and wrote a sample plugin to check if there was a problem in the context that I was sending, but my sample plugin draws properly to the window. I am getting a call for NPN_InvalidateRect twice and as a response I send an update Event back to flash. I drew a dummy rectangle to check that my context is correct. I have flipped the context to make the origin as top left corner. On doing right click on the debug version of the flash player it shows the following message: "Movie not loaded..." Can anyone give me any idea why is the content not being drawn? I would really appreciate the help, as I have been struggling with it for more than a month now. Here is a small log of the interaction that I have with flash: NPN_UserAgent Called NPN_GetValue Called with variable NPNVWindowNPObject; return NULL NPN_GetValue Called with variable NPNVWindowNPObject; return NULL NPN_GetValue Called with variable NPNVSupportsWindowless; return true NPN_SetValue Called for Variable - NPPVpluginTransparentBool; return true NPN_GetValue Called with variable NPNVsupportsCoreGraphicsBool; return true NPN_SetValue Called for Variable - NPNVpluginDrawingModel NPP_SetWindow (CoreGraphics): 0, window=0xebaa90, context=0xe4c930, window.x:0 window.y:22 window.width:480 window.height:270 NPP_HandleEvent(activateEvent) accepted:0 isActive: 1 NPP_HandleEvent(updateEvt) accepted: 1 NPN_UserAgent Called NPN_GetURLNotify Called with URL - javascript:top.location+"flashplugin_unique" NPN_GetValue Called with variable NPNVWindowNPObject; return NULL NPP_NewStream URL=/Users/mjain/Desktop/clock.swf MIME=application/x-shockwave-flash error=0 NPP_WriteReady responseURL=/Users/mjain/Desktop/clock.swf bytes=268435455 NPN_InvalidateRect Called NPP_Write responseURL=/Users/mjain/Desktop/clock.swf bytes=9925 total-delivered=9925/9925 NPP_WriteReady responseURL=/Users/mjain/Desktop/clock.swf bytes=268435455 NPP_DestroyStream responseURL=/Users/mjain/Desktop/clock.swf error=0 NPP_HandleEvent(updateEvt) accepted: 1 NPN_InvalidateRect Called NPP_HandleEvent(updateEvt) accepted: 1 NPP_NewStream URL=javascript:top.location+"flashplugin_unique" MIME=text/plain error=0 NPP_WriteReady responseURL=javascript:top.location+"flashplugin_unique" bytes=16000 NPN_UserAgent Called NPP_Write responseURL=javascript:top.location+"flashplugin_unique" bytes=52 total-delivered=52/52 NPP_WriteReady responseURL=javascript:top.location+"flashplugin_unique" bytes=16000 NPP_DestroyStream responseURL=javascript:top.location+"flashplugin_unique" error=0 NPP_URLNotify responseURL=javascript:top.location+"flashplugin_unique" reason=0 Thanks Mugdha.

    Read the article

  • Long-running ASP.NET tasks

    - by John Leidegren
    I know there's a bunch of APIs out there that do this, but I also know that the hosting environment (being ASP.NET) puts restrictions on what you can reliably do in a separate thread. I could be completely wrong, so please correct me if I am, this is however what I think I know. A request typically timeouts after 120 seconds (this is configurable) but eventually the ASP.NET runtime will kill a request that's taking too long to complete. The hosting environment, typically IIS, employs process recycling and can at any point decide to recycle your app. When this happens all threads are aborted and the app restarts. I'm however not sure how aggressive it is, it would be kind of stupid to assume that it would abort a normal ongoing HTTP request but I would expect it to abort a thread because it doesn't know anything about the unit of work of a thread. If you had to create a programming model that easily and reliably and theoretically put a long running task, that would have to run for days, how would you accomplish this from within an ASP.NET application? The following are my thoughts on the issue: I've been thinking a long the line of hosting a WCF service in a win32 service. And talk to the service through WCF. This is however not very practical, because the only reason I would choose to do so, is to send tasks (units of work) from several different web apps. I'd then eventually ask the service for status updates and act accordingly. My biggest concern with this is that it would NOT be a particular great experience if I had to deploy every task to the service for it to be able to execute some instructions. There's also this issue of input, how would I feed this service with data if I had a large data set and needed to chew through it? What I typically do right now is this SELECT TOP 10 * FROM WorkItem WITH (ROWLOCK, UPDLOCK, READPAST) WHERE WorkCompleted IS NULL It allows me to use a SQL Server database as a work queue and periodically poll the database with this query for work. If the work item completed with success, I mark it as done and proceed until there's nothing more to do. What I don't like is that I could theoretically be interrupted at any point and if I'm in-between success and marking it as done, I could end up processing the same work item twice. I might be a bit paranoid and this might be all fine but as I understand it there's no guarantee that that won't happen... I know there's been similar questions on SO before but non really answers with a definitive answer. This is a really common thing, yet the ASP.NET hosting environment is ill equipped to handle long-running work. Please share your thoughts.

    Read the article

  • Issues with MIPS interrupt for tv remote simulator

    - by pred2040
    Hello I am writing a program for class to simulate a tv remote in a MIPS/SPIM enviroment. The functions of the program itself are unimportant as they worked fine before the interrupt so I left them all out. The gaol is basically to get a input from the keyboard by means of interupt, store it in $s7 and process it. The interrupt is causing my program to repeatedly spam the errors: Exception occurred at PC=0x00400068 Bad address in data/stack read: 0x00000004 Exception occurred at PC=0x00400358 Bad address in data/stack read: 0x00000000 program starts here .data msg_tvworking: .asciiz "tv is working\n" msg_sec: .asciiz "sec -- " msg_on: .asciiz "Power On" msg_off: .asciiz "Power Off" msg_channel: .asciiz " Channel " msg_volume: .asciiz " Volume " msg_sleep: .asciiz " Sleep Timer: " msg_dash: .asciiz "-\n" msg_newline: .asciiz "\n" msg_comma: .asciiz ", " array1: .space 400 # 400 bytes of storage for 100 channels array2: .space 400 # copy of above for sorting var1: .word 0 # 1 if 0-9 is pressed, 0 if not var2: .word 0 # stores number of channel (ex. 2-) var3: .word 0 # channel timer var4: .word 0 # 1 if s pressed once, 2 if twice, 0 if not var5: .word 0 # sleep wait timer var6: .word 0 # program timer var9: .float 0.01 # for channel timings .kdata var7: .word 10 var8: .word 11 .text .globl main main: li $s0, 300 li $s1, 0 # channel li $s2, 50 # volume li $s3, 1 # power - 1:on 0:off li $s4, 0 # sleep timer - 0:off li $s5, 0 # temporary li $s6, 0 # length of sleep period li $s7, 10000 # current key press li $t2, 0 # temp value not needed across calls li $t4, 0 interrupt data here mfc0 $a0, $12 ori $a0, 0xff11 mtc0 $a0, $12 lui $t0, 0xFFFF ori $a0, $0, 2 sw $a0, 0($t0) mainloop: # 1. get external input, and process it # input from interupt is taken from $a2 and placed in $s7 #for processing beq $a2, $0, next lw $s7, 4($a2) li $a2, 0 # call the process_input function here # jal process_input next: # 2. check sleep timer mainloopnext1: # 3. delay for 10ms jal delay_10ms jal check_timers jal channel_time # 4. print status lw $s5, var6 addi $s5, $s5, 1 sw $s5, var6 addi $s0, $s0, -1 bne $s0, $0, mainloopnext4 li $s0, 300 jal status_print mainloopnext4: j mainloop li $v0,10 # exit syscall -------------------------------------------------- status_print: seconds_stat: power_stat: on_stat: off_stat: channel_stat: volume_stat: sleep_stat: j $ra -------------------------------------------------- delay_10ms: li $t0, 6000 delay_10ms_loop: addi $t0, $t0, -1 bne $t0, $0, delay_10ms_loop jr $ra -------------------------------------------------- check_timers: channel_press: sleep_press: go_back_press: channel_check: channel_ignore: sleep_check: sleep_ignore: j $ra ------------------------------------------------ process_input: beq $s7, 112, power beq $s7, 117, channel_up beq $s7, 100, channel_down beq $s7, 108, volume_up beq $s7, 107, volume_down beq $s7, 115, sleep_init beq $s7, 118, history bgt $s7, 47, end_range jr $ra end_range: power: on: off: channel_up: over: channel_down: under: channel_message: channel_time: volume_up: volume_down: volume_message: sleep_init: sleep_incr: sleep: sleep_reset: history: digit_pad_init: digit_pad: jr $ra -------------------------------------------- interupt data here, followed closely from class .ktext 0x80000180 .set noat move $k1, $at .set at sw $v0, var7 sw $a0, var8 mfc0 $k0, $13 srl $a0, $k0, 2 andi $a0, $a0, 0x1f bne $a0, $zero, no_io lui $v0, 0xFFFF lw $a2, 4($v0) # keyboard data placed in $a2 no_io: mtc0 $0, $13 mfc0 $k0, $12 andi $k0, 0xfffd ori $k0, 0x11 mtc0 $k0, $12 lw $v0, var7 lw $a0, var8 .set noat move $at, $k1 .set at eret Thanks in advance.

    Read the article

  • fresh_when in ruby not working with xml rendering

    - by Guilherme Silveira
    While trying to implement support for conditional GETting in a rest system, we have come across the fresh_when and stale? methods. The following code works fine with 304 and not further rendering: if stale?(:etag = resource, :last_modified = resource.updated_at.utc) respond_to do |format| format.html # show.html.erb } end end But accessing 1.xml will try to render the resource twice: if stale?(:etag => resource, :last_modified => resource.updated_at.utc) respond_to do |format| format.html # show.html.erb format.xml { render :xml => @order.to_xml(:controller => self, :except => [:paid_at]) } end end The error message: ActionController::DoubleRenderError in OrdersController#show Can only render or redirect once per action RAILS_ROOT: /Users/guilherme/Documents/ruby/restfulie-test Application Trace | Framework Trace | Full Trace /Library/Ruby/Gems/1.8/gems/actionpack-2.3.4/lib/action_controller/base.rb:900:in render_without_benchmark' /Library/Ruby/Gems/1.8/gems/actionpack-2.3.4/lib/action_controller/benchmarking.rb:51:in render' /Library/Ruby/Gems/1.8/gems/activesupport-2.3.4/lib/active_support/core_ext/benchmark.rb:17:in ms' /Library/Ruby/Gems/1.8/gems/activesupport-2.3.4/lib/active_support/core_ext/benchmark.rb:10:in realtime' /Library/Ruby/Gems/1.8/gems/activesupport-2.3.4/lib/active_support/core_ext/benchmark.rb:17:in ms' /Library/Ruby/Gems/1.8/gems/actionpack-2.3.4/lib/action_controller/benchmarking.rb:51:in render' /Library/Ruby/Gems/1.8/gems/actionpack-2.3.4/lib/action_controller/base.rb:1331:in send' /Library/Ruby/Gems/1.8/gems/actionpack-2.3.4/lib/action_controller/base.rb:1331:in perform_action_without_filters' /Library/Ruby/Gems/1.8/gems/actionpack-2.3.4/lib/action_controller/filters.rb:617:in call_filters' /Library/Ruby/Gems/1.8/gems/actionpack-2.3.4/lib/action_controller/filters.rb:610:in perform_action_without_benchmark' /Library/Ruby/Gems/1.8/gems/actionpack-2.3.4/lib/action_controller/benchmarking.rb:68:in perform_action_without_rescue' /Library/Ruby/Gems/1.8/gems/activesupport-2.3.4/lib/active_support/core_ext/benchmark.rb:17:in ms' /Library/Ruby/Gems/1.8/gems/activesupport-2.3.4/lib/active_support/core_ext/benchmark.rb:10:in realtime' /Library/Ruby/Gems/1.8/gems/activesupport-2.3.4/lib/active_support/core_ext/benchmark.rb:17:in ms' /Library/Ruby/Gems/1.8/gems/actionpack-2.3.4/lib/action_controller/benchmarking.rb:68:in perform_action_without_rescue' /Library/Ruby/Gems/1.8/gems/actionpack-2.3.4/lib/action_controller/rescue.rb:160:in perform_action_without_flash' /Library/Ruby/Gems/1.8/gems/actionpack-2.3.4/lib/action_controller/flash.rb:146:in perform_action' /Library/Ruby/Gems/1.8/gems/actionpack-2.3.4/lib/action_controller/base.rb:532:in send' /Library/Ruby/Gems/1.8/gems/actionpack-2.3.4/lib/action_controller/base.rb:532:in process_without_filters' /Library/Ruby/Gems/1.8/gems/actionpack-2.3.4/lib/action_controller/filters.rb:606:in process' /Library/Ruby/Gems/1.8/gems/actionpack-2.3.4/lib/action_controller/base.rb:391:in process' /Library/Ruby/Gems/1.8/gems/actionpack-2.3.4/lib/action_controller/base.rb:386:in call' /Library/Ruby/Gems/1.8/gems/actionpack-2.3.4/lib/action_controller/routing/route_set.rb:437:in `call' Any suggestions? Regards

    Read the article

  • mysql never releases memory

    - by Ishu
    I have a production server clocking about 4 million page views per month. The server has got 8GB of RAM and mysql acts as a database. I am facing problems in handling mysql to take this load. I need to restart mysql twice a day to handle this thing. The problem with mysql is that it starts with some particular occupation, the memory consumed by mysql keeps on increasing untill it reaches the maximum it can consume and then mysql stops responding slowly or does not respond at all, which freezes the server. All my tables are indexed properly and there are no long queries. I need some one to help on how to go about debugging what to do here. All my tables are myisam. I have tried configuring the parameters key_buffer etc but to no rescue. Any sort of help is greatly appreciated. Here are some parameters which may help. mysql --version mysql Ver 14.12 Distrib 5.0.77, for redhat-linux-gnu (i686) using readline 5.1 mysql> show variables; +---------------------------------+------------------------------------------------------------+ | Variable_name | Value | +---------------------------------+------------------------------------------------------------+ | auto_increment_increment | 1 | | auto_increment_offset | 1 | | automatic_sp_privileges | ON | | back_log | 50 | | basedir | /usr/ | | bdb_cache_size | 8384512 | | bdb_home | /var/lib/mysql/ | | bdb_log_buffer_size | 262144 | | bdb_logdir | | | bdb_max_lock | 10000 | | bdb_shared_data | OFF | | bdb_tmpdir | /tmp/ | | binlog_cache_size | 32768 | | bulk_insert_buffer_size | 8388608 | | character_set_client | latin1 | | character_set_connection | latin1 | | character_set_database | latin1 | | character_set_filesystem | binary | | character_set_results | latin1 | | character_set_server | latin1 | | character_set_system | utf8 | | character_sets_dir | /usr/share/mysql/charsets/ | | collation_connection | latin1_swedish_ci | | collation_database | latin1_swedish_ci | | collation_server | latin1_swedish_ci | | completion_type | 0 | | concurrent_insert | 1 | | connect_timeout | 10 | | datadir | /var/lib/mysql/ | | date_format | %Y-%m-%d | | datetime_format | %Y-%m-%d %H:%i:%s | | default_week_format | 0 | | delay_key_write | ON | | delayed_insert_limit | 100 | | delayed_insert_timeout | 300 | | delayed_queue_size | 1000 | | div_precision_increment | 4 | | keep_files_on_create | OFF | | engine_condition_pushdown | OFF | | expire_logs_days | 0 | | flush | OFF | | flush_time | 0 | | ft_boolean_syntax | + -><()~*:""&| | | ft_max_word_len | 84 | | ft_min_word_len | 4 | | ft_query_expansion_limit | 20 | | ft_stopword_file | (built-in) | | group_concat_max_len | 1024 | | have_archive | NO | | have_bdb | YES | | have_blackhole_engine | NO | | have_compress | YES | | have_crypt | YES | | have_csv | NO | | have_dynamic_loading | YES | | have_example_engine | NO | | have_federated_engine | NO | | have_geometry | YES | | have_innodb | YES | | have_isam | NO | | have_merge_engine | YES | | have_ndbcluster | NO | | have_openssl | DISABLED | | have_ssl | DISABLED | | have_query_cache | YES | | have_raid | NO | | have_rtree_keys | YES | | have_symlink | YES | | | init_connect | | | init_file | | | init_slave | | | interactive_timeout | 28800 | | join_buffer_size | 131072 | | key_buffer_size | 2621440000 | | key_cache_age_threshold | 300 | | key_cache_block_size | 1024 | | key_cache_division_limit | 100 | | language | /usr/share/mysql/english/ | | large_files_support | ON | | large_page_size | 0 | | large_pages | OFF | | lc_time_names | en_US | | license | GPL | | local_infile | ON | | locked_in_memory | OFF | | log | OFF | | log_bin | ON | | log_bin_trust_function_creators | OFF | | log_error | | | log_queries_not_using_indexes | OFF | | log_slave_updates | OFF | | log_slow_queries | ON | | log_warnings | 1 | | long_query_time | 8 | | low_priority_updates | OFF | | lower_case_file_system | OFF | | lower_case_table_names | 0 | | max_allowed_packet | 8388608 | | max_binlog_cache_size | 4294963200 | | max_binlog_size | 1073741824 | | max_connect_errors | 10 | | max_connections | 400 | | max_delayed_threads | 20 | | max_error_count | 64 | | max_heap_table_size | 16777216 | | max_insert_delayed_threads | 20 | | max_join_size | 4294967295 | | max_length_for_sort_data | 1024 | | max_prepared_stmt_count | 16382 | | max_relay_log_size | 0 | | max_seeks_for_key | 4294967295 | | max_sort_length | 1024 | | max_sp_recursion_depth | 0 | | max_tmp_tables | 32 | | max_user_connections | 0 | | max_write_lock_count | 4294967295 | | multi_range_count | 256 | | myisam_data_pointer_size | 6 | | myisam_max_sort_file_size | 2146435072 | | myisam_recover_options | OFF | | myisam_repair_threads | 1 | | myisam_sort_buffer_size | 16777216 | | myisam_stats_method | nulls_unequal | | net_buffer_length | 16384 | | net_read_timeout | 30 | | net_retry_count | 10 | | net_write_timeout | 60 | | new | OFF | | old_passwords | OFF | | open_files_limit | 2000 | | optimizer_prune_level | 1 | | optimizer_search_depth | 62 | | pid_file | /var/run/mysqld/mysqld.pid | | plugin_dir | | | port | 3306 | | preload_buffer_size | 32768 | | profiling | OFF | | profiling_history_size | 15 | | protocol_version | 10 | | query_alloc_block_size | 8192 | | query_cache_limit | 1048576 | | query_cache_min_res_unit | 4096 | | query_cache_size | 134217728 | | query_cache_type | ON | | query_cache_wlock_invalidate | OFF | | query_prealloc_size | 8192 | | range_alloc_block_size | 4096 | | read_buffer_size | 2097152 | | read_only | OFF | | read_rnd_buffer_size | 8388608 | | relay_log | | | relay_log_index | | | relay_log_info_file | relay-log.info | | relay_log_purge | ON | | relay_log_space_limit | 0 | | rpl_recovery_rank | 0 | | secure_auth | OFF | | secure_file_priv | | | server_id | 1 | | skip_external_locking | ON | | skip_networking | OFF | | skip_show_database | OFF | | slave_compressed_protocol | OFF | | slave_load_tmpdir | /tmp/ | | slave_net_timeout | 3600 | | slave_skip_errors | OFF | | slave_transaction_retries | 10 | | slow_launch_time | 2 | | socket | /var/lib/mysql/mysql.sock | | sort_buffer_size | 2097152 | | sql_big_selects | ON | | sql_mode | | | sql_notes | ON | | sql_warnings | OFF | | ssl_ca | | | ssl_capath | | | ssl_cert | | | ssl_cipher | | | ssl_key | | | storage_engine | MyISAM | | sync_binlog | 0 | | sync_frm | ON | | system_time_zone | CST | | table_cache | 256 | | table_lock_wait_timeout | 50 | | table_type | MyISAM | | thread_cache_size | 8 | | thread_stack | 196608 | | time_format | %H:%i:%s | | time_zone | SYSTEM | | timed_mutexes | OFF | | tmp_table_size | 33554432 | | tmpdir | /tmp/ | | transaction_alloc_block_size | 8192 | | transaction_prealloc_size | 4096 | | tx_isolation | REPEATABLE-READ | | updatable_views_with_limit | YES | | version | 5.0.77-log | | version_bdb | Sleepycat Software: Berkeley DB 4.1.24: (January 29, 2009) | | version_comment | Source distribution | | version_compile_machine | i686 | | version_compile_os | redhat-linux-gnu | | wait_timeout | 28800 | +---------------------------------+------------------------------------------------------------+

    Read the article

  • Exception using SQLiteDataReader

    - by galford13x
    I'm making a Custom SQLite Wrapper. This is meant to allow a presistent connection to a database. However, I receive an exception when calling this function twice. public Boolean DatabaseConnected(string databasePath) { bool exists = false; if (ConnectionOpen()) { this.Command.CommandText = string.Format(DATABASE_QUERY); using (reader = this.Command.ExecuteReader()) { while (reader.Read()) { if (string.Compare(reader[FILE_NAME_COL_HEADER].ToString(), databasePath, true) == 0) { exists = true; break; } } reader.Close(); } } return exists; } I use the above function to check if the database is currently open before executing a command or trying to open a database. The first time I execute the function, it executes with no issue. After that the reader = this.Command.ExecuteReader() throws an exception Object reference not set to an instance of an object. StackTrace: at System.Data.SQLite.SQLiteStatement.Dispose() at System.Data.SQLite.SQLite3.Reset(SQLiteStatement stmt) at System.Data.SQLite.SQLite3.Step(SQLiteStatement stmt) at System.Data.SQLite.SQLiteDataReader.NextResult() at System.Data.SQLite.SQLiteDataReader..ctor(SQLiteCommand cmd, CommandBehavior behave) at System.Data.SQLite.SQLiteCommand.ExecuteReader(CommandBehavior behavior) at System.Data.SQLite.SQLiteCommand.ExecuteReader() at EveTraderApi.Database.SQLDatabase.DatabaseConnected(String databasePath) in C:\Documents and Settings\galford13x\My Documents\Visual Studio 2008\Projects\EveTrader\EveTraderApi\Database\Database.cs:line 579 at EveTraderApi.Database.SQLDatabase.OpenSQLiteDB(String filename) in C:\Documents and Settings\galford13x\My Documents\Visual Studio 2008\Projects\EveTrader\EveTraderApi\Database\Database.cs:line 119 at EveTraderApiExample.Form1.CreateTableDataTypes() in C:\Documents and Settings\galford13x\My Documents\Visual Studio 2008\Projects\EveTrader\EveTraderApiExample\Form1.cs:line 89 at EveTraderApiExample.Form1.Button1_ExecuteCommand(Object sender, EventArgs e) in C:\Documents and Settings\galford13x\My Documents\Visual Studio 2008\Projects\EveTrader\EveTraderApiExample\Form1.cs:line 35 at System.Windows.Forms.Control.OnClick(EventArgs e) at System.Windows.Forms.Button.OnClick(EventArgs e) at System.Windows.Forms.Button.OnMouseUp(MouseEventArgs mevent) at System.Windows.Forms.Control.WmMouseUp(Message& m, MouseButtons button, Int32 clicks) at System.Windows.Forms.Control.WndProc(Message& m) at System.Windows.Forms.ButtonBase.WndProc(Message& m) at System.Windows.Forms.Button.WndProc(Message& m) at System.Windows.Forms.Control.ControlNativeWindow.OnMessage(Message& m) at System.Windows.Forms.Control.ControlNativeWindow.WndProc(Message& m) at System.Windows.Forms.NativeWindow.DebuggableCallback(IntPtr hWnd, Int32 msg, IntPtr wparam, IntPtr lparam) at System.Windows.Forms.UnsafeNativeMethods.DispatchMessageW(MSG& msg) at System.Windows.Forms.Application.ComponentManager.System.Windows.Forms.UnsafeNativeMethods.IMsoComponentManager.FPushMessageLoop(Int32 dwComponentID, Int32 reason, Int32 pvLoopData) at System.Windows.Forms.Application.ThreadContext.RunMessageLoopInner(Int32 reason, ApplicationContext context) at System.Windows.Forms.Application.ThreadContext.RunMessageLoop(Int32 reason, ApplicationContext context) at System.Windows.Forms.Application.Run(Form mainForm) at EveTraderApiExample.Program.Main() in C:\Documents and Settings\galford13x\My Documents\Visual Studio 2008\Projects\EveTrader\EveTraderApiExample\Program.cs:line 18 at System.AppDomain._nExecuteAssembly(Assembly assembly, String[] args) at System.AppDomain.ExecuteAssembly(String assemblyFile, Evidence assemblySecurity, String[] args) at Microsoft.VisualStudio.HostingProcess.HostProc.RunUsersAssembly() at System.Threading.ThreadHelper.ThreadStart_Context(Object state) at System.Threading.ExecutionContext.Run(ExecutionContext executionContext, ContextCallback callback, Object state) at System.Threading.ThreadHelper.ThreadStart()

    Read the article

  • How to avoid using duplicate savepoint names in nested transactions in nested stored procs?

    - by Gary McGill
    I have a pattern that I almost always follow, where if I need to wrap up an operation in a transaction, I do this: BEGIN TRANSACTION SAVE TRANSACTION TX -- Stuff IF @error <> 0 ROLLBACK TRANSACTION TX COMMIT TRANSACTION That's served me well enough in the past, but after years of using this pattern (and copy-pasting the above code), I've suddenly discovered a flaw which comes as a complete shock. Quite often, I'll have a stored procedure calling other stored procedures, all of which use this same pattern. What I've discovered (to my cost) is that because I'm using the same savepoint name everywhere, I can get into a situation where my outer transaction is partially committed - precisely the opposite of the atomicity that I'm trying to achieve. I've put together an example that exhibits the problem. This is a single batch (no nested stored procs), and so it looks a little odd in that you probably wouldn't use the same savepoint name twice in the same batch, but my real-world scenario would be too confusing to post. CREATE TABLE Test (test INTEGER NOT NULL) BEGIN TRAN SAVE TRAN TX BEGIN TRAN SAVE TRAN TX INSERT INTO Test(test) VALUES (1) COMMIT TRAN TX BEGIN TRAN SAVE TRAN TX INSERT INTO Test(test) VALUES (2) COMMIT TRAN TX DELETE FROM Test ROLLBACK TRAN TX COMMIT TRAN TX SELECT * FROM Test DROP TABLE Test When I execute this, it lists one record, with value "1". In other words, even though I rolled back my outer transaction, a record was added to the table. What's happening is that the ROLLBACK TRANSACTION TX at the outer level is rolling back as far as the last SAVE TRANSACTION TX at the inner level. Now that I write this all out, I can see the logic behind it: the server is looking back through the log file, treating it as a linear stream of transactions; it doesn't understand the nesting/hierarchy implied by either the nesting of the transactions (or, in my real-world scenario, by the calls to other stored procedures). So, clearly, I need to start using unique savepoint names instead of blindly using "TX" everywhere. But - and this is where I finally get to the point - is there a way to do this in a copy-pastable way so that I can still use the same code everywhere? Can I auto-generate the savepoint name on the fly somehow? Is there a convention or best-practice for doing this sort of thing? It's not exactly hard to come up with a unique name every time you start a transaction (could base it off the SP name, or somesuch), but I do worry that eventually there would be a conflict - and you wouldn't know about it because rather than causing an error it just silently destroys your data... :-(

    Read the article

  • Keeping the DI-container usage in the composition root in Silverlight and MVVM

    - by adrian hara
    It's not quite clear to me how I can design so I keep the reference to the DI-container in the composition root for a Silverlight + MVVM application. I have the following simple usage scenario: there's a main view (perhaps a list of items) and an action to open an edit view for one single item. So the main view has to create and show the edit view when the user takes the action (e.g. clicks some button). For this I have the following code: public interface IView { IViewModel ViewModel {get; set;} } Then, for each view that I need to be able to create I have an abstract factory, like so public interface ISomeViewFactory { IView CreateView(); } This factory is then declared a dependency of the "parent" view model, like so: public class SomeParentViewModel { public SomeParentViewModel(ISomeViewFactory viewFactory) { // store it } private void OnSomeUserAction() { IView view = viewFactory.CreateView(); dialogService.ShowDialog(view); } } So all is well until here, no DI-container in sight :). Now comes the implementation of ISomeViewFactory: public class SomeViewFactory : ISomeViewFactory { public IView CreateView() { IView view = new SomeView(); view.ViewModel = ???? } } The "????" part is my problem, because the view model for the view needs to be resolved from the DI-container so it gets its dependencies injected. What I don't know is how I can do this without having a dependency to the DI-container anywhere except the composition root. One possible solution would be to have either a dependency on the view model that gets injected into the factory, like so: public class SomeViewFactory : ISomeViewFactory { public SomeViewFactory(ISomeViewModel viewModel) { // store it } public IView CreateView() { IView view = new SomeView(); view.ViewModel = viewModel; } } While this works, it has the problem that since the whole object graph is wired up "statically" (i.e. the "parent" view model will get an instance of SomeViewFactory, which will get an instance of SomeViewModel, and these will live as long as the "parent" view model lives), the injected view model implementation is stateful and if the user opens the child view twice, the second time the view model will be the same instance and have the state from before. I guess I could work around this with an "Initialize" method or something similar, but it doesn't smell quite right. Another solution might be to wrap the DI-container and have the factories depend on the wrapper, but it'd still be a DI-container "in disguise" there :) Any thoughts on this are greatly appreciated. Also, please forgive any mistakes or rule-breaking, since this is my first post on stackoverflow :) Thanks! ps: my current solution is that the factories know about the DI-container, and it's only them and the composition root that have this dependency.

    Read the article

  • How to Connect Crystal Reports to MySQL directly by C# code without DSN or a DataSet

    - by Yanko Hernández Alvarez
    How can I connect a Crystal Report (VS 2008 basic) to a MySQL DB without using a DSN or a preload DataSet using C#? I need install the program on several places, so I must change the connection parameters. I don't want to create a DSN on every place, nor do I want to preload a DataSet and pass it to the report engine. I use nhibernate to access the database, so to create and fill the additional DS would take twice the work and additional maintenance later. I think the best option would be to let the crystal reports engine to connect to MySQL server by itself using ODBC. I managed to create the connection in the report designer (VS2008) using the Database Expert, creating an ODBC(RDO) connection and entering this connection string "DRIVER={MySQL ODBC 5.1 Driver};SERVER=myserver.mydomain" and in the "Next" page filling the "User ID", "Password" and "Database" parameters. I didn't fill the "Server" parameter. It worked. As a matter of fact, if you use the former connection string, it doesn't matter what you put on the "Server" parameter, it seems the parameter is unused. On the other hand, if you use "DRIVER={MySQL ODBC 5.1 Driver}" as a connection string and later fill the "Server" parameter with the FQDN of the server, the connection doesn't work. How can I do that by code? All the examples I've seen till now, use a DSN or the DataSet method. I saw the same question posted but for PostgreSQL and tried to adapt it to mysql, but so far, no success. The first method: Rp.Load(); Rp.DataSourceConnections[0].SetConnection("DRIVER={MySQL ODBC 5.1 Driver};SERVER=myserver.mydomain", "database", "user", "pass"); Rp.ExportToDisk(ExportFormatType.PortableDocFormat, "report.pdf"); raise an CrystalDecisions.CrystalReports.Engine.LogOnException during ExportToDisk Message="Logon failed.\nDetails: IM002:[Microsoft][ODBC Driver Manager] Data source name not found and no default driver specified.\rError in File temporal file path.rpt:\nUnable to connect: incorrect log on parameters. the InnerException is an System.Runtime.InteropServices.COMException with the same message and no InnerException The "no default driver specified" makes me wonder if the server parameter is unused here too (see above). In that case: How can I specify the connection string? I haven't tried the second method because it doesn't apply. Does anybody know the solution?

    Read the article

  • C# Confusing Results from Performance Test

    - by aip.cd.aish
    I am currently working on an image processing application. The application captures images from a webcam and then does some processing on it. The app needs to be real time responsive (ideally < 50ms to process each request). I have been doing some timing tests on the code I have and I found something very interesting (see below). clearLog(); log("Log cleared"); camera.QueryFrame(); camera.QueryFrame(); log("Camera buffer cleared"); Sensor s = t.val; log("Sx: " + S.X + " Sy: " + S.Y); Image<Bgr, Byte> cameraImage = camera.QueryFrame(); log("Camera output acuired for processing"); Each time the log is called the time since the beginning of the processing is displayed. Here is my log output: [3 ms]Log cleared [41 ms]Camera buffer cleared [41 ms]Sx: 589 Sy: 414 [112 ms]Camera output acuired for processing The timings are computed using a StopWatch from System.Diagonostics. QUESTION 1 I find this slightly interesting, since when the same method is called twice it executes in ~40ms and when it is called once the next time it took longer (~70ms). Assigning the value can't really be taking that long right? QUESTION 2 Also the timing for each step recorded above varies from time to time. The values for some steps are sometimes as low as 0ms and sometimes as high as 100ms. Though most of the numbers seem to be relatively consistent. I guess this may be because the CPU was used by some other process in the mean time? (If this is for some other reason, please let me know) Is there some way to ensure that when this function runs, it gets the highest priority? So that the speed test results will be consistently low (in terms of time). EDIT I change the code to remove the two blank query frames from above, so the code is now: clearLog(); log("Log cleared"); Sensor s = t.val; log("Sx: " + S.X + " Sy: " + S.Y); Image<Bgr, Byte> cameraImage = camera.QueryFrame(); log("Camera output acuired for processing"); The timing results are now: [2 ms]Log cleared [3 ms]Sx: 589 Sy: 414 [5 ms]Camera output acuired for processing The next steps now take longer (sometimes, the next step jumps to after 20-30ms, while the next step was previously almost instantaneous). I am guessing this is due to the CPU scheduling. Is there someway I can ensure the CPU does not get scheduled to do something else while it is running through this code?

    Read the article

  • pthreads_setaffinity_np: Invalid argument?

    - by hahuang65
    I've managed to get my pthreads program sort of working. Basically I am trying to manually set the affinity of 4 threads such that thread 1 runs on CPU 1, thread 2 runs on CPU 2, thread 3 runs on CPU 3, and thread 4 runs on CPU 4. After compiling, my code works for a few threads but not others (seems like thread 1 never works) but running the same compiled program a couple of different times gives me different results. For example: hao@Gorax:~/Desktop$ ./a.out Thread 3 is running on CPU 3 pthread_setaffinity_np: Invalid argument Thread Thread 2 is running on CPU 2 hao@Gorax:~/Desktop$ ./a.out Thread 2 is running on CPU 2 pthread_setaffinity_np: Invalid argument pthread_setaffinity_np: Invalid argument Thread 3 is running on CPU 3 Thread 3 is running on CPU 3 hao@Gorax:~/Desktop$ ./a.out Thread 2 is running on CPU 2 pthread_setaffinity_np: Invalid argument Thread 4 is running on CPU 4 Thread 4 is running on CPU 4 hao@Gorax:~/Desktop$ ./a.out pthread_setaffinity_np: Invalid argument My question is "Why does this happen? Also, why does the message sometimes print twice?" Here is the code: #define _GNU_SOURCE #include <stdio.h> #include <pthread.h> #include <stdlib.h> #include <sched.h> #include <errno.h> #define handle_error_en(en, msg) \ do { errno = en; perror(msg); exit(EXIT_FAILURE); } while (0) void *thread_function(char *message) { int s, j, number; pthread_t thread; cpu_set_t cpuset; number = (int)message; thread = pthread_self(); CPU_SET(number, &cpuset); s = pthread_setaffinity_np(thread, sizeof(cpu_set_t), &cpuset); if (s != 0) { handle_error_en(s, "pthread_setaffinity_np"); } printf("Thread %d is running on CPU %d\n", number, sched_getcpu()); exit(EXIT_SUCCESS); } int main() { pthread_t thread1, thread2, thread3, thread4; int thread1Num = 1; int thread2Num = 2; int thread3Num = 3; int thread4Num = 4; int thread1Create, thread2Create, thread3Create, thread4Create, i, temp; thread1Create = pthread_create(&thread1, NULL, (void *)thread_function, (char *)thread1Num); thread2Create = pthread_create(&thread2, NULL, (void *)thread_function, (char *)thread2Num); thread3Create = pthread_create(&thread3, NULL, (void *)thread_function, (char *)thread3Num); thread4Create = pthread_create(&thread4, NULL, (void *)thread_function, (char *)thread4Num); pthread_join(thread1, NULL); pthread_join(thread2, NULL); pthread_join(thread3, NULL); pthread_join(thread4, NULL); return 0; }

    Read the article

  • What's the best way to structure this Linq-to-Events Drag & Drop code?

    - by Rob Fonseca-Ensor
    I am trying to handle a drag & drop interaction, which involves mouse down, mouse move, and mouse up. Here is a simplified repro of my solution that: on mouse down, creates an ellipse and adds it to a canvas on mouse move, repositions the ellipse to follow the mouse on mouse up, changes the colour of the canvas so that it's obvious which one you're dragging. var mouseDown = Observable.FromEvent<MouseButtonEventArgs>(canvas, "MouseLeftButtonDown"); var mouseUp = Observable.FromEvent<MouseButtonEventArgs>(canvas, "MouseLeftButtonUp"); var mouseMove = Observable.FromEvent<MouseEventArgs>(canvas, "MouseMove"); Ellipse ellipse = null; var q = from start in mouseDown.Do(x => { // handle mousedown by creating a red ellipse, // adding it to the canvas at the right position ellipse = new Ellipse() { Width = 10, Height = 10, Fill = Brushes.Red }; Point position = x.EventArgs.GetPosition(canvas); Canvas.SetLeft(ellipse, position.X); Canvas.SetTop(ellipse, position.Y); canvas.Children.Add(ellipse); }) from delta in mouseMove.Until(mouseUp.Do(x => { // handle mouse up by making the ellipse green ellipse.Fill = Brushes.Green; })) select delta; q.Subscribe(x => { // handle mouse move by repositioning ellipse Point position = x.EventArgs.GetPosition(canvas); Canvas.SetLeft(ellipse, position.X); Canvas.SetTop(ellipse, position.Y); }); the XAML is simply <Canvas x:Name="canvas"/> There's a few things I don't like about this code, and I need help refactoring it :) First of all: the mousedown and mouseup callbacks are specified as side effects. If two subscriptions are made to q, they will happen twice. Second, the mouseup callback is specified before the mousemove callback. This makes it a bit hard to read. Thirdly, the reference to the ellipse seems to be in a silly place. If there's two subscriptions, that variable reference will get overwritten quite quickly. I'm sure that there should be some way we can leverage the let keyword to introduce a variable to the linq expression that will mean the correct ellipse reference is available to both the mouse move and mouse up handlers How would you write this code?

    Read the article

  • Optimizing multiple dispatch notification algorithm in C#?

    - by Robert Fraser
    Sorry about the title, I couldn't think of a better way to describe the problem. Basically, I'm trying to implement a collision system in a game. I want to be able to register a "collision handler" that handles any collision of two objects (given in either order) that can be cast to particular types. So if Player : Ship : Entity and Laser : Particle : Entity, and handlers for (Ship, Particle) and (Laser, Entity) are registered than for a collision of (Laser, Player), both handlers should be notified, with the arguments in the correct order, and a collision of (Laser, Laser) should notify only the second handler. A code snippet says a thousand words, so here's what I'm doing right now (naieve method): public IObservable<Collision<T1, T2>> onCollisionsOf<T1, T2>() where T1 : Entity where T2 : Entity { Type t1 = typeof(T1); Type t2 = typeof(T2); Subject<Collision<T1, T2>> obs = new Subject<Collision<T1, T2>>(); _onCollisionInternal += delegate(Entity obj1, Entity obj2) { if (t1.IsAssignableFrom(obj1.GetType()) && t2.IsAssignableFrom(obj2.GetType())) obs.OnNext(new Collision<T1, T2>((T1) obj1, (T2) obj2)); else if (t1.IsAssignableFrom(obj2.GetType()) && t2.IsAssignableFrom(obj1.GetType())) obs.OnNext(new Collision<T1, T2>((T1) obj2, (T2) obj1)); }; return obs; } However, this method is quite slow (measurable; I lost ~2 FPS after implementing this), so I'm looking for a way to shave a couple cycles/allocation off this. I thought about (as in, spent an hour implementing then slammed my head against a wall for being such an idiot) a method that put the types in an order based on their hash code, then put them into a dictionary, with each entry being a linked list of handlers for pairs of that type with a boolean indication whether the handler wanted the order of arguments reversed. Unfortunately, this doesn't work for derived types, since if a derived type is passed in, it won't notify a subscriber for the base type. Can anyone think of a way better than checking every type pair (twice) to see if it matches? Thanks, Robert

    Read the article

  • Occasional Date or timezone discrepancy in hudson or maven with jodatime

    - by TheStijn
    hi, I hope following explanation will make sense because it's a weird problem we're facing and hard to describe. We have a maven project which gets build in hudson and that contains some unit tests where dates are used and asserted. The hudson server runs on solaris. Now, occasionally (like 30% of the times) the unit tests using dates fail because 3,5 hours are deducted from the specified time in the unit test and hence asserts start failing. The other 70% everything works fine although nothing at all changed in the code and we run the hudson job several times an hour. I add following code to a unittest to check the time: @Test public void testDate() { System.out.println("new DateMidnight(2011, 1, 5).toDate();"); System.out.println(new DateMidnight(2011, 1, 5).toDate()); System.out.println(new DateMidnight(2011, 1, 5).toDate().getTime()); Calendar cal = Calendar.getInstance(); cal.set(Calendar.YEAR, 2011); cal.set(Calendar.MONTH, 0); cal.set(Calendar.DAY_OF_MONTH, 5); cal.set(Calendar.HOUR, 0); cal.set(Calendar.MINUTE, 0); cal.set(Calendar.SECOND, 0); cal.set(Calendar.MILLISECOND, 0); System.out.println("cal.getTime();"); System.out.println(cal.getTime()); System.out.println(cal.getTime().getTime()); } So basically it should print the same thing when using jodatime or plain old Calendar. This is the case in 70% of the runs; for the other 30% I get following printouts: Running TestSuite new DateMidnight(2011, 1, 5).toDate(); Tue Jan 04 21:30:00 MET 2011 1294173000000 cal.getTime(); Wed Jan 05 12:00:00 MET 2011 1294225200000 Local maven tests never appear the pose this problem and we can't figure out what could be the cause of it. Especially, we can't think of a single reason why the tests sometimes pass and sometimes fail without changing any code nor hudson or server setting. Also, we run the maven install with cobertura which means that the unit tests are run twice. It happens also that they pass the first time and fail the second time or the other way around or that they fail both times. Thanks for any help, Stijn

    Read the article

  • C# Begin/EndReceive - how do I read large data?

    - by ryeguy
    When reading data in chunks of say, 1024, how do I continue to read from a socket that receives a message bigger than 1024 bytes until there is no data left? Should I just use BeginReceive to read a packet's length prefix only, and then once that is retrieved, use Receive() (in the async thread) to read the rest of the packet? Or is there another way? edit: I thought Jon Skeet's link had the solution, but there is a bit of a speedbump with that code. The code I used is: public class StateObject { public Socket workSocket = null; public const int BUFFER_SIZE = 1024; public byte[] buffer = new byte[BUFFER_SIZE]; public StringBuilder sb = new StringBuilder(); } public static void Read_Callback(IAsyncResult ar) { StateObject so = (StateObject) ar.AsyncState; Socket s = so.workSocket; int read = s.EndReceive(ar); if (read > 0) { so.sb.Append(Encoding.ASCII.GetString(so.buffer, 0, read)); if (read == StateObject.BUFFER_SIZE) { s.BeginReceive(so.buffer, 0, StateObject.BUFFER_SIZE, 0, new AyncCallback(Async_Send_Receive.Read_Callback), so); return; } } if (so.sb.Length > 0) { //All of the data has been read, so displays it to the console string strContent; strContent = so.sb.ToString(); Console.WriteLine(String.Format("Read {0} byte from socket" + "data = {1} ", strContent.Length, strContent)); } s.Close(); } Now this corrected works fine most of the time, but it fails when the packet's size is a multiple of the buffer. The reason for this is if the buffer gets filled on a read it is assumed there is more data; but the same problem happens as before. A 2 byte buffer, for exmaple, gets filled twice on a 4 byte packet, and assumes there is more data. It then blocks because there is nothing left to read. The problem is that the receive function doesn't know when the end of the packet is. This got me thinking to two possible solutions: I could either have an end-of-packet delimiter or I could read the packet header to find the length and then receive exactly that amount (as I originally suggested). There's problems with each of these, though. I don't like the idea of using a delimiter, as a user could somehow work that into a packet in an input string from the app and screw it up. It also just seems kinda sloppy to me. The length header sounds ok, but I'm planning on using protocol buffers - I don't know the format of the data. Is there a length header? How many bytes is it? Would this be something I implement myself? Etc.. What should I do?

    Read the article

  • Problem with signal handlers being called too many times [closed]

    - by Hristo
    how can something print 3 times when it only goes the printing code twice? I'm coding in C and the code is in a SIGCHLD signal handler I created. void chld_signalHandler() { int pidadf = (int) getpid(); printf("pidafdfaddf: %d\n", pidadf); while (1) { int termChildPID = waitpid(-1, NULL, WNOHANG); if (termChildPID == 0 || termChildPID == -1) { break; } dll_node_t *temp = head; while (temp != NULL) { printf("stuff\n"); if (temp->pid == termChildPID && temp->type == WORK) { printf("inside if\n"); // read memory mapped file b/w WORKER and MAIN // get statistics and write results to pipe char resultString[256]; // printing TIME int i; for (i = 0; i < 24; i++) { sprintf(resultString, "TIME; %d ; %d ; %d ; %s\n",i,1,2,temp->stats->mboxFileName); fwrite(resultString, strlen(resultString), 1, pipeFD); } remove_node(temp); break; } temp = temp->next; } printf("done printing from sigchld \n"); } return; } the output for my MAIN process is this: MAIN PROCESS 16214 created WORKER PROCESS 16220 for file class.sp10.cs241.mbox pidafdfaddf: 16214 stuff stuff inside if done printing from sigchld MAIN PROCESS 16214 created WORKER PROCESS 16221 for file class.sp10.cs225.mbox pidafdfaddf: 16214 stuff stuff inside if done printing from sigchld and the output for the MONITOR process is this: MONITOR: pipe is open for reading MONITOR PIPE: TIME; 0 ; 1 ; 2 ; class.sp10.cs225.mbox MONITOR PIPE: TIME; 0 ; 1 ; 2 ; class.sp10.cs225.mbox MONITOR PIPE: TIME; 0 ; 1 ; 2 ; class.sp10.cs241.mbox MONITOR: end of readpipe ( I've taken out repeating lines so I don't take up so much space ) Thanks, Hristo

    Read the article

  • Offline backup synchronization

    - by Pavan Kumar
    There is a Central Server running Windows Server 2003 and SQL Server 2005 and there are 7 client machines situated in various places and has XP Pro & SQL Server 2005 installed in all of them. They are not interconnected so they are physically seperate. One person goes to each of these centers maybe twice a month and takes the backup (Full database consisting of mdf and ldf files) with a pen drive and brings it to the Central server which contains the central database holding same schema as all the other client databases. I need to synchronize each backup database (belonging to different centers) one by one to update the existing data or inserting new data in the central database . The solution i got was Replication. The pendrive is brought to central server consisting of 7 instances of the databases and then the databases is attached to the central server one by one to the same SQL Server where the central database exists. Then my idea was to replicate the backup database one by one i.e using single subscription (Central Database) and multiple publication ( i.e 7 instances of databases in my case) toplogy by performing replication locally (i.e in the same machine). So i tried to develop a UI in C# .Net to programatically run the Transactional Replication with push subscription using RMO Programming (which is incomplete as of now because there is no point in developing when you already know it is not the solution). Transactional Replication can either be set to initialize with a snapshot or without a snapshot. If i go for the first option i.e with a snapshot , the data whatever is present in Central Database is overwritten by the new data . So the data present initially in the central database is lost. If i try to initialize without snapshot , no data (the data already has the updated and new data) will be sent from the backup database to server. The replication will work in a scenario where any incremental changes is done only after you set the replication . So the initial data whatever was present in the backup database when setting up the replication will not be replicated when running the snapshot agent for the first time to synchronize. Only changes in the backup database thereafter will be reflected to the central database .(Remember I am not going to insert new data or make any changes to the backup database after i attach it to the Central Server. ) So this solution is not feasible. I want a solution for synchronizing from one client database to central database present in the same machine using C#.NET. If you can provide me small example maybe with two databases(with same schema) DB1(Client) to DB2(Server) consisting of one or two tables it will be very helpful. The synchronization is not bidirectional.I want to only update existing data or insert new data from DB1 to DB2 (DB2 may contain some data initially). Thanks and Regards Pavan

    Read the article

  • Problem with signal handlers

    - by Hristo
    how can something print 3 times when it only goes the printing code twice? I'm coding in C and the code is in a SIGCHLD signal handler I created. void chld_signalHandler() { int pidadf = (int) getpid(); printf("pidafdfaddf: %d\n", pidadf); while (1) { int termChildPID = waitpid(-1, NULL, WNOHANG); if (termChildPID == 0 || termChildPID == -1) { break; } dll_node_t *temp = head; while (temp != NULL) { printf("stuff\n"); if (temp->pid == termChildPID && temp->type == WORK) { printf("inside if\n"); // read memory mapped file b/w WORKER and MAIN // get statistics and write results to pipe char resultString[256]; // printing TIME int i; for (i = 0; i < 24; i++) { sprintf(resultString, "TIME; %d ; %d ; %d ; %s\n",i,1,2,temp->stats->mboxFileName); fwrite(resultString, strlen(resultString), 1, pipeFD); } remove_node(temp); break; } temp = temp->next; } printf("done printing from sigchld \n"); } return; } the output for my MAIN process is this: MAIN PROCESS 16214 created WORKER PROCESS 16220 for file class.sp10.cs241.mbox pidafdfaddf: 16214 stuff stuff inside if done printing from sigchld MAIN PROCESS 16214 created WORKER PROCESS 16221 for file class.sp10.cs225.mbox pidafdfaddf: 16214 stuff stuff inside if done printing from sigchld and the output for the MONITOR process is this: MONITOR: pipe is open for reading MONITOR PIPE: TIME; 0 ; 1 ; 2 ; class.sp10.cs225.mbox MONITOR PIPE: TIME; 0 ; 1 ; 2 ; class.sp10.cs225.mbox MONITOR PIPE: TIME; 0 ; 1 ; 2 ; class.sp10.cs241.mbox MONITOR: end of readpipe ( I've taken out repeating lines so I don't take up so much space ) Thanks, Hristo

    Read the article

  • How to integrate Purify into Hudson CI?

    - by Martin
    Hello everybody! I have a Hudson CI system set up and for the moment it is used for building a project and running some unit tests. My next step is to integrate the memory leak detector Purify into the build cycle. Now I want to start the unit tests also inside purify and for this I have created a new batch task which runs following command: purify.exe /SaveTextData MyExecutable.exe --test TestLibrary.dll --output xml As I read in the Purify documentation the /SaveTextData option is used in order to run purify not in GUI mode. If I run this command on my local workstation in the command line it works perfectly. But in case it is started by Hudson, nothing happens. Unfortunetly there are no logs of purify... Has someone ever tried to start purify either by Hudson or any other CI system? Thanks in advance. Best regards Martin EDIT: I forgot to tell you, that I have Hudson running as master and slave on different computers. On the master I have configured a task which should start the unit tests within purify on the slave. I am running the slave via JNLP. EDIT 18.03.2010: Ok, so finally I am a bit closer the source of the problem. I have discovered, that running my unit tests in purify locally the log file EngineCmdLine.log contains three commands. I am starting purify with following command: purify.exe /SaveTextData TestRunnerConsoleWD.exe --test TestDemoWD.dll Output of EngineCmdLine.log when starting purify manually: File: D:\workspace\hudson\workspace\Purify_TestFW_CommonsCoreTest_Cpp_msvs9\TestRunnerConsoleWD.exe File: C:\WINDOWS\system32\ws2_32.dll File: D:\workspace\hudson\workspace\Purify_TestFW_CommonsCoreTest_Cpp_msvs9\TestDemoWD.dll Output when starting via Hudson: File: D:\workspace\hudson\workspace\Purify_TestFW_CommonsCoreTest_Cpp_msvs9\TestRunnerConsoleWD.exe File: C:\WINDOWS\system32\ws2_32.dll File: D:\workspace\hudson\workspace\Purify_TestFW_CommonsCoreTest_Cpp_msvs9\TestDemoWD.dll File: D:\workspace\hudson\workspace\Purify_TestFW_CommonsCoreTest_Cpp_msvs9\TestDemoWD.dll The error output of purify: Instrumenting: BtcTestDemoWD.dll 313856 bytes Purify: While processing file D:\workspace\hudson\workspace\Purify_TestFW_CommonsCoreTest_Cpp_msvs9\TESTFWWD.DLL: Error: Cannot replace file c:\Programme\IBM\RationalPurifyPlus\PurifyPlus\cache\BTCTESTFWWD$Purify_D_workspace_hudson_workspace_Purify_TestFW_CommonsCoreTest_Cpp_msvs9.DLL. Is it in use? TESTFWWD.DLL 505344 bytes Unable to instrument D:\workspace\hudson\workspace\Purify_TestFW_CommonsCoreTest_Cpp_msvs9\TestDemoWD.dll (0x1) Question is, why is purify starting twice a command with the TestDemoWD.dll library?

    Read the article

  • JavaScript: Doing some stuff right before the user exits the page

    - by Mike
    I have seen some questions here regarding what I want to achieve and have based what I have so far on those answer. But there is a slight misbehavior that is still irritating me. What I have is sort of a recovery feature. Whenever you are typing text, the client sends a sync request to the server every 45 seconds. It does 2 things. First, it extends the lease the client has on the record (only one person may edit at one time) for another 60 seconds. Second, it sends the text typed so far to the server in case the server crashes, internet connection fails, etc. In that case, the next time the user enters our application, the user is notified that something has gone wrong and that some text was recovered. Think of Microsoft or OpenOffice recovery whenever they crash! Of course, if the user leaves the page willingly, the user does not need to be notified and as a result, the recovery is deleted. I do that final request via a beforeunload event. Everything went fine until I was asked to make a final adjustment... The same behavior you have here at stack overflow when you exit the editor... a confirm dialogue. This works so far, BUT, the confirm dialogue is shown twice. Here is the code. The event if (local.sync.autosave_textelement) { window.onbeforeunload = exitConfirm; } The function function exitConfirm() { var local = Core; if (confirm('blub?')) { local.sync.autosave_destroy = true; sync(false); return true; } else { return false; } }; Some problem irrelevant clarifications: Core is a global Object that contains a lot of variables that are used everywhere. sync makes an ajax request. The values are based on the values that the Core.sync object contains. The parameter determines if the call should be async (default) or sync.

    Read the article

  • Subclassing a window from a thread in c#

    - by user258651
    I'm creating a thread that looks for a window. When it finds the window, it overrides its windowproc, and handles WM_COMMAND and WM_CLOSE. Here's the code that looks for the window and subclasses it: public void DetectFileDialogProc() { Window fileDialog = null; // try to find the dialog twice, with a delay of 500 ms each time for (int attempts = 0; fileDialog == null && attempts < 2; attempts++) { // FindDialogs enumerates all windows of class #32770 via an EnumWindowProc foreach (Window wnd in FindDialogs(500)) { IntPtr parent = NativeMethods.User32.GetParent(wnd.Handle); if (parent != IntPtr.Zero) { // we're looking for a dialog whose parent is a dialog as well Window parentWindow = new Window(parent); if (parentWindow.ClassName == NativeMethods.SystemWindowClasses.Dialog) { fileDialog = wnd; break; } } } } // if we found the dialog if (fileDialog != null) { OldWinProc = NativeMethods.User32.GetWindowLong(fileDialog.Handle, NativeMethods.GWL_WNDPROC); NativeMethods.User32.SetWindowLong(fileDialog.Handle, NativeMethods.GWL_WNDPROC, Marshal.GetFunctionPointerForDelegate(new WindowProc(WndProc)).ToInt32()); } } And the windowproc: public IntPtr WndProc(IntPtr hWnd, uint msg, IntPtr wParam, IntPtr lParam) { lock (this) { if (!handled) { if (msg == NativeMethods.WM_COMMAND || msg == NativeMethods.WM_CLOSE) { // adding to a list. i never access the window via the hwnd from this list, i just treat it as a number _addDescriptor(hWnd); handled = true; } } } return NativeMethods.User32.CallWindowProc(OldWinProc, hWnd, msg, wParam, lParam); } This all works well under normal conditions. But I am seeing two instances of bad behavior in order of badness: If I do not close the dialog within a minute or so, the app crashes. Is this because the thread is getting garbage collected? This would kind of make sense, as far as GC can tell the thread is done? If this is the case, (and I don't know that it is), how can I make the thread stay around as long as the dialog is around? If I immediately close the dialog with the 'X' button (WM_CLOSE) the app crashes. I believe its crashing in the windowproc, but I can't get a breakpoint in there. I'm getting an AccessViolationException, The exception says "Attempted to read or write protected memory. This is often an indication that other memory is corrupt." Its a race condition, but of what I don't know. FYI, I had been reseting the old windowproc once I processed the commands, but that was crashing even more often! Any ideas on how I can solve these issues?

    Read the article

  • Activate a (COM Interop based) ActiveX contol using registration free com

    - by embnut
    I have a (COM Interop based) ActiveX contol that I am trying to use with registration free com. When the control loads the control is inactive (does not responds to events, control not fully rendered etc). After much search I discovered that COM objects using reg-free-com use the miscStatus attribute to set the initial state to get correctly activated. I know how to use it with a comClass which corresponds to a native COM Object. 1) What is the equivalent of the following for clrClass element which corresponds to a COM-interop object? <comClass clsid="{qqqqqqqq-wwww-eeee-rrrr-00C0F0283628}" tlbid="{xxxxxxxx-yyyy-zzzz-aaaa-0000F8754DA1}" threadingModel="Both" progid="SomeCompany.SomeOleControl" description="Some ActiveX Control" miscStatus="recomposeonresize,insideout,activatewhenvisible,nouiactivate" > 2) The COM client I am using is Visual FoxPro. If the (1) is not possible what can I do in VFP to activate the inactive ActiveX control. (I dont mind VB or C# input too if I can use it to find the equivalent foxpro) Currently I tried the following this.AddObject('OleControl1', 'oleControl', 'SomeCompany.SomeOleControl') this.OleControl1.AutoActivate = 3 this.OleControl1.Visible = .T. this.OleControl1.SetFocus But I the OleControl1 gets focus before passing events like mouse click to its subelements. So I have to click twice on it to do the necessary action, any time it does not have focus. I would like the control to act as if the "nouiactivate" of the miscStatus value is set. 3) Is there any other way of accomplishing what I want to do? Hans Passant, here is the listing of current Assembly.dll.manifest. The formatting in the comment made it unreadable. <?xml version="1.0" encoding="UTF-8" standalone="yes"?> <assembly xmlns="urn:schemas-microsoft-com:asm.v1" manifestVersion="1.0"> <assemblyIdentity name="Assembly" version="1.0.0.0" type="win32" publicKeyToken="wwwwwwwwwwwwwwww"/> <clrClass name="SomeCompany.SomeOleControl" clsid="{qqqqqqqq-wwww-eeee-rrrr-00C0F0283628}" progid="SomeCompany.SomeOleControl" threadingModel="Both"/> <file name="Assembly.tlb"> <typelib tlbid="{xxxxxxxx-yyyy-zzzz-aaaa-0000F8754DA1}" version="1.0" helpdir="" flags="hasdiskimage"/> </file> </assembly>

    Read the article

  • Window Media Player issues two requests for the audio on web page

    - by Ron Harlev
    I'm using Windows Media Player in a web page. I have version 11 installed so that is the version I'm testing with right now. The player is embedded on the page with this HTML: <OBJECT id='MS_mediaPlayer' width="400" height="45" classid='CLSID:6BF52A52-394A-11D3-B153-00C04F79FAA6' codebase='http://activex.microsoft.com/activex/controls/mplayer/en/nsmp2inf.cab#Version=5,1,52,701' standby='Loading Microsoft Windows Media Player components...' type='application/x-oleobject'> <param name='autoStart' value="false"> <param name='uiMode' value="invisible"> <param name='loop' value="false"> </OBJECT> I'm calling in JavaScript: MS_mediaPlayer.URL = "SomeAudioFile.mp3" MS_mediaPlayer.controls.play(); When I look at Fiddler I can see that the player actually downloads "SomeAudioFile.mp3" twice. Is there some setting I have wrong? I was trying to set the "autoPlay" to true and avoid calling "play()". Got the same result - two downloads. UPDATE: The first request's user-agent is "Windows-Media-Player/11.0.5721.5268". The second has "Mozilla/4.0 (compatible; MSIE 7.0; Windows NT 5.1; GTB6; .NET CLR 1.1.4322; .NET CLR 2.0.50727; .NET CLR 3.0.04506.30; .NET CLR 3.0.04506.648; .NET CLR 3.5.21022; .NET CLR 3.0.4506.2152; .NET CLR 3.5.30729)". Looks like the browser is running the same request the second time. No Idea why Any ideas? UPDATE (4/1/10): Still no solution. I debugged the JS thoroughly and there is only one call to MediaPlayer.URL='.....' to set the audio file. Nothing else triggers the media player to load the file and there is no other place referencing the audio file on the page. One other interesting fact is that this doesn't happen (the double loading of the audio) when I run the browser locally on my development web server. But other remote requests to the same web server generate the double audio loading. I believe I eliminated any correlation with specific IE version or media player version. This happens with IE6-8 and WM9-12

    Read the article