Search Results

Search found 4049 results on 162 pages for 'serial communication'.

Page 9/162 | < Previous Page | 5 6 7 8 9 10 11 12 13 14 15 16  | Next Page >

  • Communication between state machines with hidden transitions

    - by slartibartfast
    The question emerged for me in embedded programming but I think it can be applied to quite a number of general networking situations e.g. when a communication partner fails. Assume we have an application logic (a program) running on a computer and a gadget connected to that computer via e.g. a serial interface like RS232. The gadget has a red/green/blue LED and a button which disables the LED. The LEDs color can be driven by software commands over the serial interface and the state (red/green/blue/off) is read back and causes a reaction in the application logic. Asynchronous behaviour of the application logic with regard to the LED color down to a certain delay (depending on the execution cycle of the application) is tolerated. What we essentially have is a resource (the LED) which can not be reserved and handled atomically by software because the (organic) user can at any time press the button to interfere/break the software attempt to switch the LED color. Stripping this example from its physical outfit I dare to say that we have two communicating state machines A (application logic) and G (gadget) where G executes state changes unbeknownst to A (and also the other way round, but this is not significant in our example) and only A can be modified at a reasonable price. A needs to see the reaction and state of G in one piece of information which may be (slightly) outdated but not inconsistent with respect to the short time window when this information was generated on the side of G. What I am looking for is a concise method to handle such a situation in embedded software (i.e. no layer/framework like CORBA etc. available). A programming technique which is able to map the complete behaviour of both participants on classical interfaces of a classical programming language (C in this case). To complicate matters (or rather, to generalize), a simple high frequency communication cycle of A to G and back (IOW: A is rapidly polling G) is out of focus because of technical restrictions (delay of serial com, A not always active, etc.). What I currently see as a general solution is: the application logic A as one thread of execution an adapter object (proxy) PG (presenting G inside the computer), together with the serial driver as another thread a communication object between the two (A and PG) which is transactionally safe to exchange The two execution contexts (threads) on the computer may be multi-core or just interrupt driven or tasks in an RTOS. The com object contains the following data: suspected state (written by A): effectively a member of the power set of states in G (in our case: red, green, blue, off, red_or_green, red_or_blue, red_or_off...etc.) command data (written by A): test_if_off, switch_to_red, switch_to_green, switch_to_blue operation status (written by PG): operation_pending, success, wrong_state, link_broken new state (written by PG): red, green, blue, off The idea of the com object is that A writes whichever (set of) state it thinks G is in, together with a command. (Example: suspected state="red_or_green", command: "switch_to_blue") Notice that the commands issued by A will not work if the user has switched off the LED and A needs to know this. PG will pick up such a com object and try to send the command to G, receive its answer (or a timeout) and set the operation status and new state accordingly. A will take back the oject once it is no longer at operation_pending and can react to the outcome. The com object could be separated of course (into two objects, one for each direction) but I think it is convenient in nearly all instances to have the command close to the result. I would like to have major flaws pointed out or hear an entirely different view on such a situation.

    Read the article

  • Connecting to MSP430 via /dev/ttyACM0

    - by speciousfool
    I'd like some suggestions about how to fix garbled serial output from a device connected on /dev/ttyACM0. Lately I've been working on a development project making use of TI's MSP430 microcontroller (specifically the eZ430-RF2560). Over on this thread you can see we've been testing some code and have found that the output of the microcontroller over serial is garbled. The btstack provides simple counter test program. When we run the program and look at the serial port output using PuTTY on Windows 7 we see: rfcomm_send_internal cid 117 doesn't exist! BTstack counter 26230 rfcomm_send_internal cid 117 doesn't exist! BTstack counter 26231 However if we connect from various Ubuntu clients we get something like: Stt.R. BTacn 0 BTacn 002BTacn 0 BTcct 04BTtacoe 5BTacun My current belief is that this is because the device is being detected by cdc_acm as a generic USB ACM device. Another thread about a similar microcontroller suggests that the device should use a specific usb serial driver. We've verified that the module is compiled on our system and did a "modprobe ti_usb_3410_5052" but this had no effect on cdc_acm. Here is the relevant section of the kernel's debug log: [ 2735.092987] usb 2-1.2: new full speed USB device number 5 using ehci_hcd [ 2735.213655] cdc_acm 2-1.2:1.0: This device cannot do calls on its own. It is not a modem. [ 2735.213669] cdc_acm 2-1.2:1.0: No union descriptor, testing for castrated device [ 2735.213720] cdc_acm 2-1.2:1.0: ttyACM0: USB ACM device [ 2745.241996] generic-usb 0003:0451:F432.0003: usb_submit_urb(ctrl) failed [ 2745.242023] generic-usb 0003:0451:F432.0003: timeout initializing reports [ 2745.242401] generic-usb 0003:0451:F432.0003: hiddev0,hidraw0: USB HID v1.01 Device [Texas Instruments Texas Instruments MSP-FET430UIF] on usb-0000:00:1d.0-1.2/input1 So, in summary, we'd like to figure out how to properly connect to this device. Also of use may be the appropriate place to file a bug report.

    Read the article

  • Log Debug Messages without Debug Serial on Shipped Device

    - by Kate Moss' Open Space
    Debug message is one of the ancient but useful way for problem resolving. Message is redirected to PB if KITL is enabled otherwise it goes to default debug port, usually a serial port on most of the platform but it really depends on how OEMWriteDebugString and OEMWriteDebugByte are implemented. For many reasons, we don't want to have a debug serial port, for example, we don't have enough spare serial ports and it can affect the performance. So some of the BSP designers decide to dump the messages into other media, could be a log file, shared memory or any solution that is suitable for the need. In CE 5.0 and previous, OAL and Kernel are linked into one binaries; in the other word, you can use whatever function in kernel, such as SC_CreateFileW to access filesystem in OAL, even this is strongly not recommended. But since the OAL is being a standalone executable in CE 6.0, we no longer can use this back door but only interface exported in NKGlobal which just provides enough for OAL but no more. Accessing filesystem or using sync object to communicate to other drivers or application is even not an option. Sounds like the kernel lock itself up; of course, OAL is in kernel space, you can still do whatever you want to hack into kernel, but once again, it is not only make it a dirty solution but also fragile. So isn't there an elegant solution? Let's see how a debug message print out. In private\winceos\COREOS\nk\kernel\printf.c, the OutputDebugStringW is the one for pumping out the messages; most of the code is for error handling and serialization but what really interesting is the following code piece     if (g_cInterruptsOff) {         OEMWriteDebugString ((unsigned short *)str);     } else {         g_pNKGlobal->pfnWriteDebugString ((unsigned short *)str);     }     CELOG_OutputDebugString(dwActvProcId, dwCurThId, str); It outputs the message to default debug output (is redirected to KITL when available) or OAL when needed but note that highlight part, it also invokes CELOG_OutputDebugString. Follow the thread to private\winceos\COREOS\nk\logger\CeLogInstrumentation.c, this function dump whatever input to CELOG. So whatever the debug message is we always got a clone in CELOG. General speaking, all of the debug message is logged to CELOG already, so what you need to do is using celogflush.exe with CELZONE_DEBUG zone, and then viewing the data using the by Readlog tool. Here are some information about these tools CELOG - http://msdn.microsoft.com/en-us/library/ee479818.aspx READLOG - http://msdn.microsoft.com/en-us/library/ee481220.aspx Also for advanced reader, I encourage you to dig into private\winceos\COREOS\nk\celog\celogdll, the source of CELOG.DLL and use it as a starting point to create a more lightweight debug message logger for your own device!

    Read the article

  • Developer’s Life – Attitude and Communication – They Can Cause Problems – Notes from the Field #027

    - by Pinal Dave
    [Note from Pinal]: This is a 27th episode of Notes from the Field series. The biggest challenge for anyone is to understand human nature. We human have so many things on our mind at any moment of time. There are cases when what we say is not what we mean and there are cases where what we mean we do not say. We do say and things as per our mood and our agenda in mind. Sometimes there are incidents when our attitude creates confusion in the communication and we end up creating a situation which is absolutely not warranted. In this episode of the Notes from the Field series database expert Mike Walsh explains a very crucial issue we face in our career, which is not technical but more to relate to human nature. Read on this may be the best blog post you might read in recent times. In this week’s note from the field, I’m taking a slight departure from technical knowledge and concepts explained. We’ll be back to it next week, I’m sure. Pinal wanted us to explain some of the issues we bump into and how we see some of our customers arrive at problem situations and how we have helped get them back on the right track. Often it is a technical problem we are officially solving – but in a lot of cases as a consultant, we are really helping fix some communication difficulties. This is a technical blog post and not an “advice column” in a newspaper – but the longer I am a consultant, the more years I add to my experience in technology the more I learn that the vast majority of the problems we encounter have “soft skills” included in the chain of causes for the issue we are helping overcome. This is not going to be exhaustive but I hope that sharing four pieces of advice inspired by real issues starts a process of searching for places where we can be the cause of these challenges and look at fixing them in ourselves. Or perhaps we can begin looking at resolving them in teams that we manage. I’ll share three statements that I’ve either heard, read or said and talk about some of the communication or attitude challenges highlighted by the statement. 1 – “But that’s the SAN Administrator’s responsibility…” I heard that early on in my consulting career when talking with a customer who had serious corruption and no good recent backups – potentially no good backups at all. The statement doesn’t have to be this one exactly, but the attitude here is an attitude of “my job stops here, and I don’t care about the intent or principle of why I’m here.” It’s also a situation of having the attitude that as long as there is someone else to blame, I’m fine…  You see in this case, the DBA had a suspicion that the backups were not being handled right.  They were the DBA and they knew that they had responsibility to ensure SQL backups were good to go – it’s a basic requirement of a production DBA. In my “As A DBA Where Do I start?!” presentation, I argue that is job #1 of a DBA. But in this case, the thought was that there was someone else to blame. Rather than create extra work and take on responsibility it was decided to just let it be another team’s responsibility. This failed the company, the company’s customers and no one won. As technologists – we should strive to go the extra mile. If there is a lack of clarity around roles and responsibilities and we know it – we should push to get it resolved. Especially as the DBAs who should act as the advocates of the data contained in the databases we are responsible for. 2 – “We’ve always done it this way, it’s never caused a problem before!” Complacency. I have to say that many failures I’ve been paid good money to help recover from would have not happened had it been for an attitude of complacency. If any thoughts like this have entered your mind about your situation you may be suffering from it. If, while reading this, you get this sinking feeling in your stomach about that one thing you know should be fixed but haven’t done it.. Why don’t you stop and go fix it then come back.. “We should have better backups, but we’re on a SAN so we should be fine really.” “Technically speaking that could happen, but what are the chances?” “We’ll just clean that up as a fast follow” ..and so on. In the age of tightening IT budgets, increased expectations of up time, availability and performance there is no room for complacency. Our customers and business units expect – no demand – the best. Complacency says “we will give you second best or hopefully good enough and we accept the risk and know this may hurt us later. Sometimes an organization will opt for “good enough” and I agree with the concept that at times the perfect can be the enemy of the good. But when we make those decisions in a vacuum and are not reporting them up and discussing them as an organization that is different. That is us unilaterally choosing to do something less than the best and purposefully playing a game of chance. 3 – “This device must accept interference from other devices but not create any” I’ve paraphrased this one – but it’s something the Federal Communications Commission – a federal agency in the United States that regulates electronic communication – requires of all manufacturers of any device that could cause or receive interference electronically. I blogged in depth about this here (http://www.straightpathsql.com/archives/2011/07/relationship-advice-from-the-fcc/) so I won’t go into much detail other than to say this… If we all operated more on the premise that we should do our best to not be the cause of conflict, and to be less easily offended and less upset when we perceive offense life would be easier in many areas! This doesn’t always cause the issues we are called in to help out. Not directly. But where we see it is in unhealthy relationships between the various technology teams at a client. We’ll see teams hoarding knowledge, not sharing well with others and almost working against other teams instead of working with them. If you trace these problems back far enough it often stems from someone or some group of people violating this principle from the FCC. To Sum It Up Technology problems are easy to solve. At Linchpin People we help many customers get past the toughest technological challenge – and at the end of the day it is really just a repeatable process of pattern based troubleshooting, logical thinking and starting at the beginning and carefully stepping through to the end. It’s easy at the end of the day. The tough part of what we do as consultants is the people skills. Being able to help get teams working together, being able to help teams take responsibility, to improve team to team communication? That is the difficult part, and we get to use the soft skills on every engagement. Work on professional development (http://professionaldevelopment.sqlpass.org/) and see continuing improvement here, not just with technology. I can teach just about anyone how to be an excellent DBA and performance tuner, but some of these soft skills are much more difficult to teach. If you want to get started with performance analytics and triage of virtualized SQL Servers with the help of experts, read more over at Fix Your SQL Server. Reference: Pinal Dave (http://blog.sqlauthority.com)Filed under: Notes from the Field, PostADay, SQL, SQL Authority, SQL Query, SQL Server, SQL Tips and Tricks, T SQL

    Read the article

  • What is proper way to detect all available serial ports on Windows?

    - by Sorin Sbarnea
    There are several ways to list serial ports under Windows but I'm not sure what is the proper way: the way that does detect all serial ports that are available. One good code example is http://www.naughter.com/enumser.html - where there at 9 (nine!) ways of enumerating serial devices. The question is: what is the optimal way of doing it. Requirements: * to not open ports in order to check if they are available. * to be able to detect ports with different names than COMx.

    Read the article

  • Microsoft Press Deal of the Day - 9/Jul/2012 - Windows® Communication Foundation 4 Step by Step

    - by TATWORTH
    Today's Deal of the Day from Microsoft Press at http://shop.oreilly.com/product/0790145302403.do?code=MSDEAL is Windows® Communication Foundation 4 Step by Step"Teach yourself the essentials of Windows Communication Foundation (WCF) 4 -- one step at a time. With this practical, learn-by-doing tutorial, you get the clear guidance and hands-on examples you need to begin creating Web services for robust Windows-based business applications. Discover how to: Build and host SOAP and REST servicesMaintain service contracts and data contractsControl configuration and communications programmaticallyImplement message encryption, authentication, and authorizationManage identity with Windows CardSpaceBegin working with Windows Workflow Foundation to create scalable and durable business servicesImplement service discovery and message routingOptimize performance with service throttling, encoding, and streamingIntegrate WCF services with ASP.NET clients and enterprise services components"  Note the comment:Use code: MSDEAL

    Read the article

  • PCI-e SEALEVEL dual serial card not recognized on Ubuntu 14.04

    - by kwhunter
    New to Ubuntu, running 14.04. I have trouble with the serial port setup, I have a plug-in PCI-e SEALEVEL dual serial card that is not recognized. user1@WSIWORKSTATION2:~$ dmesg | grep tty [ 0.000000] console [tty0] enabled [ 1.577197] 00:06: ttyS0 at I/O 0x3f8 (irq = 4, base_baud = 115200) is a 16550A [ 1.943326] tty ttyprintk: hash matches [ 17.240880] ttyS4: LSR safety check engaged! [ 17.241589] ttyS4: LSR safety check engaged! [ 17.242354] ttyS5: LSR safety check engaged! [ 17.243058] ttyS5: LSR safety check engaged! [ 17.243918] ttyS6: LSR safety check engaged! [ 17.244485] ttyS6: LSR safety check engaged! [ 17.245195] ttyS7: LSR safety check engaged! [ 17.245830] ttyS7: LSR safety check engaged! [ 17.246554] ttyS8: LSR safety check engaged! [ 17.247191] ttyS8: LSR safety check engaged! user1@WSIWORKSTATION2:~/Desktop/seacom$ lspci -d 135e: -vvv 02:04.0 Bridge: Sealevel Systems Inc Device e205 (rev aa) Subsystem: Sealevel Systems Inc Device e205 Control: I/O+ Mem+ BusMaster+ SpecCycle- MemWINV+ VGASnoop- ParErr- Stepping- SERR+ FastB2B- DisINTx- Status: Cap+ 66MHz+ UDF- FastB2B+ ParErr- DEVSEL=medium TAbort- SERR- Capabilities: However, the manufacturer's drivers won't install: 1. user1@WSIWORKSTATION2:~/Desktop/seacom$ make install ---------------------------------------------------------------- Installing seacom suite. ---------------------------------------------------------------- --Installing utilities-- /usr/bin/ld: skipping incompatible ../../lib/libftd2xx.a when searching for -lftd2xx /usr/bin/ld: cannot find -lftd2xx collect2: error: ld returned 1 exit status make[2]: *** [setusb] Error 1 make[1]: *** [install] Error 1 make: *** [install] Error 1 2. user1@WSIWORKSTATION2:~/Desktop/seaio$ make install ---------------------------------------------------------------- Installing SD suite. ---------------------------------------------------------------- *Compiling SeaIO Library source file: digitalIoDevice.cpp gcc: error trying to exec 'cc1plus': execvp: No such file or directory make[1]: *** [digitalIoDevice.o] Error 1 make: *** [install] Error 1 I was not able to find a solution, so if anyone can help it will be much appreciated. PS Have some troubles with formatting my post, apologies...

    Read the article

  • How to generate unique serial number of machine in Delphi?

    - by noxwow
    Hi, I have question how to generate unique serial number of machine in Delphi? I tried to do this using the ID the motherboard or processor, but unfortunately it's unfortunately supported. Partition serial numbers, etc. fall off, because it is changing after the formatted. I'm looking for something that doesn't change after the formatted. Has anyone any idea?

    Read the article

  • Connecting to a switch?

    - by Kravlin
    I have a managed switch that i liberated from our school's surplus goods store for $10 that has a serial based console. I have a serial cable and a computer with a serial port, but i have no idea what protocal to use to connect between the two. I'm running Arch Linux on the computer with the serial port. Thanks

    Read the article

  • How to clear a zone from a broken Bind/Named server

    - by Cerin
    I tried adding a new zone for "mydomain4.com" to my Named DNS server. However, when I went to restart it, I received the unhelpful error message: Error in named configuration: zone mydomain4.com/IN: loaded serial 3 zone mydomain3.com/IN: loaded serial 2 zone mydomain2.com/IN: loaded serial 2 zone mydomain1.com/IN: loaded serial 2 zone mydomain0.com/IN: loaded serial 6 zone localhost.localdomain/IN: loaded serial 0 zone localhost/IN: loaded serial 0 zone 1.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.ip6.arpa/IN: loaded serial 0 zone 1.0.0.127.in-addr.arpa/IN: loaded serial 0 zone 0.in-addr.arpa/IN: loaded serial 0 zone mydomain/IN: loaded serial 2010092201 dns_rdata_fromtext: db.10.157.10:27: near '*.mydomain4.com.': bad name (check-names) zone 10.157.10.in-addr.arpa/IN: loading from master file db.10.157.10 failed: bad name (check-names) zone 10.157.10.in-addr.arpa/IN: not loaded due to errors. _default/10.157.10.in-addr.arpa/IN: bad name (check-names) I'm confused by this, since I thought I created the new zone identically to how I created the other 4 zones. However, since I need this DNS server up, I tried deleting the new zone file at /var/named/chroot/var/named/mydomain4.com.db. However, upon trying to restart again, I received a new unhelpful error: Error in named configuration: zone mydomain4.com/IN: loading from master file mydomain4.com.db failed: file not found zone mydomain4.com/IN: not loaded due to errors. _default/mydomain4.com./IN: file not found zone mydomain3.com/IN: loaded serial 2 zone mydomain2.com/IN: loaded serial 2 zone mydomain1.com/IN: loaded serial 2 zone mydomain0.com/IN: loaded serial 6 zone localhost.localdomain/IN: loaded serial 0 zone localhost/IN: loaded serial 0 zone 1.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.ip6.arpa/IN: loaded serial 0 zone 1.0.0.127.in-addr.arpa/IN: loaded serial 0 zone 0.in-addr.arpa/IN: loaded serial 0 zone mydomain/IN: loaded serial 2010092201 dns_rdata_fromtext: db.10.157.10:27: near '*.mydomain4.com.': bad name (check-names) zone 10.157.10.in-addr.arpa/IN: loading from master file db.10.157.10 failed: bad name (check-names) zone 10.157.10.in-addr.arpa/IN: not loaded due to errors. _default/10.157.10.in-addr.arpa/IN: bad name (check-names) Obviously, named still thinks the zone file is being used, but I can't find where. I've tried doing: grep -lir "mydomain4" / but it doesn't find any files containing that text. How do I purge this domain from named's configs? Also, how do I figure out what caused the original error?

    Read the article

  • WARNING Retrying Bulk Insert for file:sqlldr due to Communication Error:256

    - by user702295
    WARNING Retrying Bulk Insert for file:sqlldr due to Communication Error:256 I am running my engine on Linux and am receiving an intermittent message "WARNING Retrying bulk insert for file: sqlldr due to communication Error: 256" The engine seems to have completed successfully, but it is not clear if this error caused some of the forecast to not complete. It is also not clear what caused the error. Generally if you see only the WARNING of it, it means that next retries of the same load request have eventually succeeded and so the run a a whole is not affected. In order to know more about what happens, look for .log/.bad files left in the engines bin directory or possibly a quote of them within the specific engine log that had the issue.  The sqlnet.log file may also have some information about it and perhaps at the database server side there may be some log/alert regarding what happened.  Look at the alert.log. In general it could be that the database server/network was over loaded at the time and somehow the connection was rejected/failed/aborted either due to specific setting on concurrent connections/sessions or inadvertently due to glitch in network/os/hardware. If this repeats and becomes more frequent during the run you should look further into it as mentioned above. You can also track this using either SQL*Trace or java.util.logging.  - Globally enable logging by setting the oracle.jdbc.Trace system property java -Doracle.jdbc.Trace=true - Client Side Tracing: Your SQLNET.ORA file should contain the following lines to produce a client side trace file: trace_level_client = 10 trace_unique_client = on trace_file_client = sqlnet.trc trace_directory_client = <path_to_trace_dir> Server Side Tracing: To enable server side tracing, use the following parameters: trace_level_server = 10 trace_file_server = server.trc trace_directory_server = <path_to_trace_dir> Tracing Levels: The following values can be used for TRACE_LEVEL* parameters:     16 or SUPPORT — WorldWide Customer Support trace information     10 or ADMIN — Administration trace information     4 or USER — User trace information     0 or OFF — no tracing, the default Additional information is readily available via the web.

    Read the article

  • Setting serial RS232 port settings; any in C# alternatives to SerialPort class ?

    - by adrin
    In my .NET application I need to achieve serial port setup equivalent to this C++ managed code: ::SetCommMask(m_hCOMM, EV_RXCHAR); ::SetupComm(m_hCOMM, 9*2*128*10, 400); ::PurgeComm(m_hCOMM, PURGE_TXABORT|PURGE_RXABORT|PURGE_TXCLEAR|PURGE_RXCLEAR); COMMTIMEOUTS timeOut; timeOut.ReadIntervalTimeout = 3; timeOut.ReadTotalTimeoutConstant = 3; timeOut.ReadTotalTimeoutMultiplier = 1; timeOut.WriteTotalTimeoutConstant = 0; timeOut.WriteTotalTimeoutMultiplier= 0; int nRet= ::SetCommTimeouts(m_hCOMM, &timeOut); ::EscapeCommFunction(m_hCOMM, SETDTR); ::EscapeCommFunction(m_hCOMM, SETRTS); DCB dcb; memset(&dcb, 0, sizeof(DCB)); dcb.BaudRate= m_nSpeed; dcb.ByteSize= 8; dcb.fParity = FALSE; dcb.Parity = NOPARITY; dcb.StopBits= ONESTOPBIT; dcb.fBinary = TRUE; dcb.fDsrSensitivity= FALSE; dcb.fOutxDsrFlow= FALSE; dcb.fOutxCtsFlow= FALSE; dcb.fDtrControl = DTR_CONTROL_HANDSHAKE; dcb.fRtsControl = RTS_CONTROL_TOGGLE; nRet= ::SetCommState(m_hCOMM, &dcb); Is it possible at all? How do I approach this problem? Are there any (preferable free) libraries that allow such low level serial port control or should I create my own wrapper on top of Win32 api? Anyone did anything similar or has an idea how to 'glue' win32 serial port api with .net so that I can use neat .NET DataReceived() events ? Or maybe I can create .NET SerialPort instance and then modify it using managed API?

    Read the article

  • How do you send an extended-ascii AT-command (CCh) from Android bluetooth to a serial device?

    - by softex
    This one really has me banging my head. I'm sending alphanumeric data from an Android app, through the BluetoothChatService, to a serial bluetooth adaptor connected to the serial input of a radio transceiver. Everything works fine except when I try to configure the radio on-the-fly with its AT-commands. The AT+++ (enter command mode) is received OK, but the problem comes with the extended-ascii characters in the next two commands: Changing the radio destination address (which is what I'm trying to do) requires CCh 10h (plus 3 hex radio address bytes), and exiting the command mode requires CCh ATO. I know the radio can be configured OK because I've done it on an earlier prototype with the serial commands from PIC basic, and it also can be configured by entering the commands directly from hyperterm. Both these methods somehow convert that pesky CCh into a form the radio understands. I've have tried just about everything an Android noob could possibly come up with to finagle the encoding such as: private void command_address() { byte[] addrArray = {(byte) 0xCC, 16, 36, 65, 21, 13}; CharSequence addrvalues = EncodingUtils.getString(addrArray, "UTF-8"); sendMessage((String) addrvalues); } but no matter what, I can't seem to get that high-order byte (CCh/204/-52) to behave as it should. All other (< 127) bytes, command or data, transmit with no problem. Any help here would be greatly appreciated. -Dave

    Read the article

  • Give write access to USB and Serial devices automatically

    - by Saeid87
    I am working with some USB and Serial micro-controllers. Everytime I plug a device I have to do the following command to give it write access, and also my password: sudo chmod 666 /dev/ttyUSB0 Can I set my Ubuntu to automatically give write access to pluged in devices? If not, how can I make a batch file that I can easily give the access to port I want for example if I run the following command it does the job: giveaccess -usb0

    Read the article

  • Python, Raspberry, and Arduino Communication

    - by user2924156
    I have been working with my Raspberry, Arduino and applying some Python to make them communicate. I also installed pyserial. If I use IDLE and try the following I get my expected results. >>> import serial >>> ser = serial.Serial('/dev/ttyUSB0',115200) >>> ser.write('x:1\n') 8 >>> ser.readline() 'X:1\r\n' If I write a python scrip and run it I don't get anything back. Here is my python script. import serial ser = serial.Serial('/dev/ttyUSB0', 115200) ser.write('!x:1\n') ser.readline() I am new to Python so looking for some help to understand they this works in IDLE but not as a python script run from terminal. Thanks.

    Read the article

  • connect two computers together via a rs232 serial port

    - by Richard
    Wondering if anyone knows of a solution to connect with telnet/ssh through a rs232 serial port Edit: I am looking for a way to connect to computers together via a serial port. I want to be able to view the file system of a computer through a serial port.. Is this possible? Edit: So I have successfully connected two computers together using r232 serial ports with a null modem. The instructions I have used are located here Now how do I get to the file system of the host computer?? Any ideas?

    Read the article

  • Serial communication in between VM and ESX?

    - by user41685
    I am in verse to understand the serial communication between guest and host.I have just added a serial port through VI Client selecting "Use serial port on host"(host being ESX host).If I am on VM and run : ll /dev/ttyS0 I understand that it should get displayed through ESX Host. So On ESX Host, I typed: cat /dev/ttyS0 But nothing worked !!!

    Read the article

< Previous Page | 5 6 7 8 9 10 11 12 13 14 15 16  | Next Page >