  • Is it possible to have DisplayLink USB display hotplugging with Xorg 1.13 on kernel 3.4?

    - by lkraav
    keithp seems to be the only one on the interwebs to have written anything about the subject and he worked with 3.5_rc. I don't want to go above 3.4 at the moment for various stability reasons and am trying to see whether I can get this to work. Xorg 1.13 recognizes the display on connection, "udl" module is loaded, xorg-video-modesetting driver also loads, display lights up. So everything seems to be good. I emerged xrandr-9999 (not many changes on top of 1.3.5): $ xrandr --listproviders Providers: number : 2 Provider 0: id: 69 cap: 0x0 crtcs: 2 outputs: 4 associated providers: 0 name:Intel Provider 1: id: 338 cap: 0x0 crtcs: 1 outputs: 1 associated providers: 0 name:modesetting But I can't get any further, just like this guy: $ xrandr --setprovideroutputsource 338 69 X Error of failed request: BadValue (integer parameter out of range for operation) Major opcode of failed request: 139 (RANDR) Minor opcode of failed request: 35 () Value in failed request: 0x152 Serial number of failed request: 11 Current serial number in output stream: 12 $ xrandr --setprovideroutputsource 1 0 X Error of failed request: 148 Major opcode of failed request: 139 (RANDR) Minor opcode of failed request: 35 () Serial number of failed request: 11 Current serial number in output stream: 12 Any thoughts?

    Read the article

  • Can Current Backflow from Powered Hub's Adapter & cause PC Damage?

    - by SuperUserMan
    Getting this short: Can current flow from a powered USB hub's power adapter (lying 10 Meter away) back to computer via usb port and cause damage to Computer components like mobo, etc? What should be my concerns? Using a 2 Amp 5V Power adapter to power a 10m Long Active Repeater USB extension cable with 4 port HUB & plugging into PC's Front port, causes PC Chassis fan to keep running (thought slower than regular speed) Front Chassis HDD & power LED to turn on (though bit dim) may be other things which i cant detect/see at chip level, in motherboard?? All this even after PC is shut down (bit scary) More detail (in case still want to read): To run 4 High power (needing 450 mAmps) Wifi Adapters, far away from PC, Bought Active Repeater USB Extension Cable with 4 Ports & power port at far end http://www.ebay.com/itm/33FT-USB-2-0-Male-to-Female-Extension-Cable-Hub-Splitter-Adapter-with-4-USB-Port-/390846115254 Then added a locally bought 2 Amp 240V AC to 5V DC Power Adapter and plugged into USB hub which is a part of & situated at far end of a 10 Meter Active Repeater usb extension cable. Even 4 Wifi Adapters run fine (appear to) using this setup, but running chassis fan, dimly lighted Power & HDD LED, even when PC is switched off is bit scary and surely mean 5V & some current is flowing all though that 10 meter extension cable into my USB port & powering stuff. Can this cause damage? and what should be my concerns. Of course I can't switch off the power adapter (lying 10 meters away from PC) every time I switch off my PC to prevent this.

    Read the article

  • iperf max udp multicast performance peaking at 10Mbit/s?

    - by Tom Frey
    I'm trying to test UDP multicast throughput via iperf but it seems like it's not sending more than 10Mbit/s from my dev machine: C:\> iperf -c 224.0.166.111 -u -T 1 -t 100 -i 1 -b 1000000000 ------------------------------------------------------------ Client connecting to 224.0.166.111, UDP port 5001 Sending 1470 byte datagrams Setting multicast TTL to 1 UDP buffer size: 8.00 KByte (default) ------------------------------------------------------------ [156] local 192.168.1.99 port 49693 connected with 224.0.166.111 port 5001 [ ID] Interval Transfer Bandwidth [156] 0.0- 1.0 sec 1.22 MBytes 10.2 Mbits/sec [156] 1.0- 2.0 sec 1.14 MBytes 9.57 Mbits/sec [156] 2.0- 3.0 sec 1.14 MBytes 9.55 Mbits/sec [156] 3.0- 4.0 sec 1.14 MBytes 9.56 Mbits/sec [156] 4.0- 5.0 sec 1.14 MBytes 9.56 Mbits/sec [156] 5.0- 6.0 sec 1.15 MBytes 9.62 Mbits/sec [156] 6.0- 7.0 sec 1.14 MBytes 9.53 Mbits/sec When I run it on another server, I'm getting ~80Mbit/s which is quite a bit better but still not anywhere near the 1Gbps limits that I should be getting? C:\> iperf -c 224.0.166.111 -u -T 1 -t 100 -i 1 -b 1000000000 ------------------------------------------------------------ Client connecting to 224.0.166.111, UDP port 5001 Sending 1470 byte datagrams Setting multicast TTL to 1 UDP buffer size: 8.00 KByte (default) ------------------------------------------------------------ [180] local 10.0.101.102 port 51559 connected with 224.0.166.111 port 5001 [ ID] Interval Transfer Bandwidth [180] 0.0- 1.0 sec 8.60 MBytes 72.1 Mbits/sec [180] 1.0- 2.0 sec 8.73 MBytes 73.2 Mbits/sec [180] 2.0- 3.0 sec 8.76 MBytes 73.5 Mbits/sec [180] 3.0- 4.0 sec 9.58 MBytes 80.3 Mbits/sec [180] 4.0- 5.0 sec 9.95 MBytes 83.4 Mbits/sec [180] 5.0- 6.0 sec 10.5 MBytes 87.9 Mbits/sec [180] 6.0- 7.0 sec 10.9 MBytes 91.1 Mbits/sec [180] 7.0- 8.0 sec 11.2 MBytes 94.0 Mbits/sec Anybody has any idea why this is not achieving close to link limits (1Gbps)? Thanks, Tom

    Read the article

  • Are my iptables secure?

    - by Patricia
    I have this in my rc.local on my new Ubuntu server: iptables -F iptables -A INPUT -i eth0 -p tcp --sport 22 -m state --state ESTABLISHED -j ACCEPT iptables -A OUTPUT -o eth0 -p tcp --dport 22 -m state --state NEW,ESTABLISHED -j ACCEPT iptables -A INPUT -i eth0 -p tcp --dport 22 -m state --state NEW,ESTABLISHED -j ACCEPT iptables -A OUTPUT -o eth0 -p tcp --sport 22 -m state --state ESTABLISHED -j ACCEPT iptables -A OUTPUT -o eth0 -p tcp --dport 9418 -m state --state NEW,ESTABLISHED -j ACCEPT iptables -A INPUT -i eth0 -p tcp --sport 9418 -m state --state ESTABLISHED -j ACCEPT iptables -A OUTPUT -o eth0 -p tcp --dport 5000 -m state --state NEW,ESTABLISHED -j ACCEPT # Heroku iptables -A INPUT -i eth0 -p tcp --sport 5000 -m state --state ESTABLISHED -j ACCEPT # Heroku iptables -A INPUT -p udp -s 74.207.242.5/32 --source-port 53 -d 0/0 --destination-port 1024:65535 -j ACCEPT iptables -A INPUT -p udp -s 74.207.241.5/32 --source-port 53 -d 0/0 --destination-port 1024:65535 -j ACCEPT iptables -A OUTPUT -o eth0 -p tcp --dport 443 -m state --state NEW,ESTABLISHED -j ACCEPT iptables -A INPUT -i eth0 -p tcp --sport 443 -m state --state ESTABLISHED -j ACCEPT iptables -P INPUT DROP iptables -P FORWARD DROP 9418 is Git's port. 5000 is a port used to manage Heroku apps. And 74.207.242.5 and 74.207.241.5 are our DNS servers. Do you think that this is secure? Can you see any holes here? Update: Why is it important to block OUTPUT? This machine will be used only by me.

    Read the article

  • How to connect 2 routers (Asmax and D-link)

    - by piobyz
    I just bought a new router, D-link DSL 2641B and want to connect it to another one, provided by my ISP, Asmax AR 804MP. Previously, I had Linksys WRT350N, and there was no problem, while I had Ethernet cable plugged in to one of LAN ports in Asmax and INTERNET(RJ45) port in Linksys, connection used PPPoE protocol -- worked OK. D-link has DSL(RJ11) port (which I don't want to use as Asmax replacement, while there is a separate Ethernet cable with a TV plugged to Asmax, which I don't want to configure from scratch on D-link). How should I connect my new D-link to work with Asmax? Via DSL port? Via one of the LAN ports (in which case I probably should change the purpose of this port in the config, I guess?). I tried connecting D-link both ways: LAN(ASMAX) to LAN(DLINK) LAN(ASMAX) to DSL(DLINK) (using RJ11 - RJ45 cable) I hope there is some setting in the DLINK's config that I overlooked. I haven't tried to see what's in ASMAX's config, but I guess I don't need to change anything there, while Linksys worked just fine? The only difference I see, is that D-link has RJ11 DSL port as WAN, and Linksys has RJ45 (called by them INTERNET) as a main WAN port.

    Read the article

  • Not getting IP from ISP on Multicast Network

    - by Johan Nielsen
    Im having an odd issue with my ISP (COMX.dk) I have a managed access gateway box (Telsay) with three 8P8C ports for use with Internet and Ip-Tv (respectively on different VLANS (so does my ISP tell me)) To utilize a port you will need to register your device's mac address through an online interface. You will then get your device paired with a static ip. I am using one port actively and I have registered another device (router). The router is configured to listen for an active dhcpd on the network. When my router get a lease I get a private ip 192.168.2.2 (not the one bound to my mac) which is odd! I unconnected my router from the gateway and connected my laptop directly. Same thing happened - I was given a private address. I did a port scan on the gateway and found port 80 to be open and browsed to the ip. I was then presented with a management interface of a Belkin wireless router (HMMM!!!!) <--by the way, not my gear At this point I called the ISP to let them know of my issue/findings - Only to be replied "Well, we cant see any rogue dhcp servers" (thinking to myself, well I can) I then decided that it could be fun to try the other port of my gateway, only to experience the same. So I reconnected my router and used the remaining port to make an observer(wireshark promic etc.) I am able to see my router trying to discover a dhcp server but I can also see my ISP's IGMP and PIMv2 packages just repeating the same pattern. Hello...Hello...Hello :) So I called them again, only to get the same response, "we dont see any rogue dhcp's...we cant see the host you are talking to (mac address of the Belkin router)...you are definitively connected through wireless?!?(no im not, no such thing as a wireless wire - i thought to myself)" My questions is, What is going on? (besides from what im reporting here) What am I seeing that the don't? What can I tell them in order for them to resolve mine/their issue?

    Read the article

  • HP dv6910 laptop no longer recognizes wireless adapter, dvd drive, and one usb port. What can I do about this?

    - by Joan H.
    In the last 3 weeks, my not even 3 year old HP laptop (vista) just seems to be failing. First, one of the usb ports stopped working. Next, the dvd drive all of a sudden was not recognized as even existing, so it is now useless. And as of today, I no longer seem to have a wireless adapter on my laptop. It doesn't show up in device manager, same as the dvd drive. I can connect to the internet by ethernet cable, but not wirelessly. It worked fine last night; now it doesn't even exist! I have tried a 'hard reset' I read about on HP's forum- no help. I am not sure what else to try. I read about the USB wifi dongle in another response, but I already have maxed our my usb ports even though I have bought a USB hub since the one port failed. Plus, I'd like my laptop to just work like it's supposed to instead of being jerry rigged with usb hubs, external dvd drives, and wifi dongles etc. Any ideas?

    Read the article

  • How to play WAV file through Network Paging Interface

    - by BGM
    In our building we have a Viking Paging ZPI-4 Interface for our intercom. The interface receives data from our Asterisk Phone system via a Cisco SPA112 Port Adapter which has it's own IP address on the network and converts digital into analog. Asterisk plays the "5" tone and then allows the user's voice to commence over the connection. Now, what I want to do is to play a wav file over this Viking Paging device using the Cisco Port Adapter. I know how to get Asterisk to do it, but I want to do this without Asterisk. I want some kind of program that can talk to the Cisco Port Adapter and then transmit the wav file into the Viking Paging Device. What kind of program do I need to get or make? Now, I found this link if it helps anyone with ideas. I also found this information, but I'm not sure how to apply it. I also found this, but it involves an arduino. However, I already have the analog-to-digital convertor, and the Viking will handle sending sound over the paging speakers. I just need to know how to send the wav file to the Viking via the Port Adapter. So far, I know my wav file should be formatted as 8bit mono, and I need to send the "5" tone to open the Viking Pager's channel. [update] I am trying to figure out if I can use VLC player to stream to the ipaddress of the Port Adapter. So far I'm not having success with that, and don't even know if it will work. Windows Media Player has a streaming option too. I am thinking that since the Cisco Port Adapter thinks it is a sort of phone, that the only way this can be done is via SIP.

    Read the article

  • Simple vLAN setup

    - by Logan Bissonnette
    I have a basic lab environment set up to try and get 2 vLANs working in hyper-v. I have the following equipment 1 hyper-v server 1 Desktop PC 1 Managed Switch (d-link DES-3052P) 1 cheap router (DI-604) My end goal is to have 1 VM and the desktop on one vLAN with internet, and 1 VM on a separate vLAN with internet access. I am having troubles getting an internet connection to both vLANs. The switch does not have the ability to have asynchronous vLANs. This is my switch configuration Port 1 - Trunk Port - Connected to router Port 2 - Trunk Port - Connected to hyper-v Server Port 3 - Access Port- Connected to Desktop Within hyper-v I have 1 switch and 2 VMs. When the VMs are set up to use vlan ID 1, everything works fine. As soon as a VM is set up to use vlan ID 2, they lose all network connection and cannot communicate with the router anymore. I believe this is because the router is not vLAN aware. Can anyone help me with what settings need to be set up on my switch? I believe I want an egress rule so traffic leaving towards the router is untagged, is that right? If not, any ideas or hints as to what needs to be set up?

    Read the article

  • esx5 debian VM vlan setup

    - by Kstro21
    i have a server with ESX5, have a switch with about 20 vlans, this is how setup the trunk port interface GigabitEthernet0/1/1 description ToOper port link-type trunk undo port trunk allow-pass vlan 1 port trunk allow-pass vlan 2 to 14 stp disable ntdp enable ndp enable bpdu enable then, i created a standar switch(sw1) using the vSphere Client, the VLAN ID is set to All (4095), i also created a VM with Debian 6, with a NIC connected to sw1, now, i want to configure this NIC for a selected group of vlans auto vlan10 iface vlan10 inet static address 11.10.1.0 netmask 255.255.255.224 mtu 1500 vlan_raw_device eth0 auto vlan14 iface vlan14 inet static address 11.10.1.65 netmask 255.255.255.248 mtu 1500 vlan_raw_device eth0 so, when i restart the network using /etc/init.d/networking restart, i got this error Reconfiguring network interfaces...SIOCSIFADDR: No such device vlan14: ERROR while getting interface flags: No such device SIOCSIFNETMASK: No such device SIOCSIFBRDADDR: No such device vlan14: ERROR while getting interface flags: No such device SIOCSIFMTU: No such device vlan14: ERROR while getting interface flags: No such device Failed to bring up vlan14. done. this is just part of the error, so, my questions is: is this possible?, i mean, what i'm trying to achieve using ESX Virtual Machines, VLANS, etc is this a Debian problem? can be solved? i've read about a file named z25_persistent-net.rules in Debian but it doesn't exist in my installation. in the In the vSphere Networking for ESX5 guide, you can read: If you enter 0 or leave the option blank, the port group can see only untagged (non-VLAN) traffic. If you enter 4095, the port group can see traffic on any VLAN while leaving the VLAN tags intact. So, in theory, it should work, right? Hope you can help me up with this one Thanks

    Read the article

  • use ssh tunnel with phpmyadmin

    - by JohnMerlino
    I been using ssh tunnel to bypass firewall of remote mysql server. On my Ubuntu 12.04 installation, it works via the terminal and it works when using a program called mysql workbench. However, that program freezes often and I want to try phpmyadmin as an alternative. However, I cannot connect to remote server using ssh tunnel on phpmyadmin, albeit I can connect locally. These are the steps I've tried: 1) Open a tunnel, listening on localhost:3307 and forwarding everything to xxx.xxx.xxx.xxx:3306 (used 3307 because MySQL on my local machine uses the default port 3306): ssh -L 3307:localhost:3306 [email protected] So now I have the port for tunnel open and I have my local mysql installation default port: $ netstat -tln Active Internet connections (only servers) Proto Recv-Q Send-Q Local Address Foreign Address State tcp 0 0 127.0.0.1:3306 0.0.0.0:* LISTEN tcp 0 0 127.0.0.1:3307 0.0.0.0:* LISTEN tcp 0 0 0.0.0.0:80 0.0.0.0:* LISTEN ... 2) Now I can easily connect to remote server via localhost using the terminal: $ mysql -u user.name -p -h 127.0.0.1 -P 3307 Notice that I expicitly identify 3307 as the port, so traffic forwards to the remote server, and hence it logs me in to the remote server. Unfortunately, the localhost/phpmyadmin local login interface doesn't allow you to specify a port option. So I modify the config-db.php file and change the $dbport variable to 3307, under the impression that the phpmyadmin interface will now work with port 3307: $ sudo vim /etc/phpmyadmin/config-db.php $dbport='3307'; Then I restart the mysql server. Unfortunately, it didn't work. When I use the remote credentials to login, it gives me error: #1045 Cannot log in to the MySQL server

    Read the article

  • Compare cells in two different spreadsheets and extract data from one an place it in the other if match found

    - by Fergie
    I need to find a way to compare two spreadsheets and if there is a match on specific cells, pull data from one sheet to another. Say the two spreadsheets contain a value that identifies a piece of equipment: spreadsheet 1 spreadsheet 2 Server Server Serial # 123abc 123abc 123-xx-456 There are of course many, many records/rows in each sheet. I need to look at the first cell in the server column of sheet 1 and then search a range of cells in the sever column of sheet 2 for a match. If there is a match, I need to pull the serial # value from the cell in the matching row an put it into the serial # cell of the matching row in sheet 1 (all of the "serial #" cells in sheet 1 are presently empty.) If that description explaination is too convoluted I can explain by answering any questions you may have. My deadline for this task is Noon tomorrow, 30 Aug 2012. Yes, I got the task today at noon.... I am not an Excel user and just get thrust into it on occassion... Any help would be a huge assist.

    Read the article

  • LSI 9285-8e and Supermicro SC837E26-RJBOD1 duplicate enclosure ID and slot numbers

    - by Andy Shinn
    I am working with 2 x Supermicro SC837E26-RJBOD1 chassis connected to a single LSI 9285-8e card in a Supermicro 1U host. There are 28 drives in each chassis for a total of 56 drives in 28 RAID1 mirrors. The problem I am running in to is that there are duplicate slots for the 2 chassis (the slots list twice and only go from 0 to 27). All the drives also show the same enclosure ID (ID 36). However, MegaCLI -encinfo lists the 2 enclosures correctly (ID 36 and ID 65). My question is, why would this happen? Is there an option I am missing to use 2 enclosures effectively? This is blocking me rebuilding a drive that failed in slot 11 since I can only specify enclosure and slot as parameters to replace a drive. When I do this, it picks the wrong slot 11 (device ID 46 instead of device ID 19). Adapter #1 is the LSI 9285-8e, adapter #0 (which I removed due to space limitations) is the onboard LSI. Adapter information: Adapter #1 ============================================================================== Versions ================ Product Name : LSI MegaRAID SAS 9285-8e Serial No : SV12704804 FW Package Build: 23.1.1-0004 Mfg. Data ================ Mfg. Date : 06/30/11 Rework Date : 00/00/00 Revision No : 00A Battery FRU : N/A Image Versions in Flash: ================ BIOS Version : 5.25.00_4.11.05.00_0x05040000 WebBIOS Version : 6.1-20-e_20-Rel Preboot CLI Version: 05.01-04:#%00001 FW Version : 3.140.15-1320 NVDATA Version : 2.1106.03-0051 Boot Block Version : 2.04.00.00-0001 BOOT Version : 06.253.57.219 Pending Images in Flash ================ None PCI Info ================ Vendor Id : 1000 Device Id : 005b SubVendorId : 1000 SubDeviceId : 9285 Host Interface : PCIE ChipRevision : B0 Number of Frontend Port: 0 Device Interface : PCIE Number of Backend Port: 8 Port : Address 0 5003048000ee8e7f 1 5003048000ee8a7f 2 0000000000000000 3 0000000000000000 4 0000000000000000 5 0000000000000000 6 0000000000000000 7 0000000000000000 HW Configuration ================ SAS Address : 500605b0038f9210 BBU : Present Alarm : Present NVRAM : Present Serial Debugger : Present Memory : Present Flash : Present Memory Size : 1024MB TPM : Absent On board Expander: Absent Upgrade Key : Absent Temperature sensor for ROC : Present Temperature sensor for controller : Absent ROC temperature : 70 degree Celcius Settings ================ Current Time : 18:24:36 3/13, 2012 Predictive Fail Poll Interval : 300sec Interrupt Throttle Active Count : 16 Interrupt Throttle Completion : 50us Rebuild Rate : 30% PR Rate : 30% BGI Rate : 30% Check Consistency Rate : 30% Reconstruction Rate : 30% Cache Flush Interval : 4s Max Drives to Spinup at One Time : 2 Delay Among Spinup Groups : 12s Physical Drive Coercion Mode : Disabled Cluster Mode : Disabled Alarm : Enabled Auto Rebuild : Enabled Battery Warning : Enabled Ecc Bucket Size : 15 Ecc Bucket Leak Rate : 1440 Minutes Restore HotSpare on Insertion : Disabled Expose Enclosure Devices : Enabled Maintain PD Fail History : Enabled Host Request Reordering : Enabled Auto Detect BackPlane Enabled : SGPIO/i2c SEP Load Balance Mode : Auto Use FDE Only : No Security Key Assigned : No Security Key Failed : No Security Key Not Backedup : No Default LD PowerSave Policy : Controller Defined Maximum number of direct attached drives to spin up in 1 min : 10 Any Offline VD Cache Preserved : No Allow Boot with Preserved Cache : No Disable Online Controller Reset : No PFK in NVRAM : No Use disk activity for locate : No Capabilities ================ RAID Level Supported : RAID0, RAID1, RAID5, RAID6, RAID00, RAID10, RAID50, RAID60, PRL 11, PRL 11 with spanning, SRL 3 supported, PRL11-RLQ0 DDF layout with no span, PRL11-RLQ0 DDF layout with span Supported Drives : SAS, SATA Allowed Mixing: Mix in Enclosure Allowed Mix of SAS/SATA of HDD type in VD Allowed Status ================ ECC Bucket Count : 0 Limitations ================ Max Arms Per VD : 32 Max Spans Per VD : 8 Max Arrays : 128 Max Number of VDs : 64 Max Parallel Commands : 1008 Max SGE Count : 60 Max Data Transfer Size : 8192 sectors Max Strips PerIO : 42 Max LD per array : 16 Min Strip Size : 8 KB Max Strip Size : 1.0 MB Max Configurable CacheCade Size: 0 GB Current Size of CacheCade : 0 GB Current Size of FW Cache : 887 MB Device Present ================ Virtual Drives : 28 Degraded : 0 Offline : 0 Physical Devices : 59 Disks : 56 Critical Disks : 0 Failed Disks : 0 Supported Adapter Operations ================ Rebuild Rate : Yes CC Rate : Yes BGI Rate : Yes Reconstruct Rate : Yes Patrol Read Rate : Yes Alarm Control : Yes Cluster Support : No BBU : No Spanning : Yes Dedicated Hot Spare : Yes Revertible Hot Spares : Yes Foreign Config Import : Yes Self Diagnostic : Yes Allow Mixed Redundancy on Array : No Global Hot Spares : Yes Deny SCSI Passthrough : No Deny SMP Passthrough : No Deny STP Passthrough : No Support Security : No Snapshot Enabled : No Support the OCE without adding drives : Yes Support PFK : Yes Support PI : No Support Boot Time PFK Change : Yes Disable Online PFK Change : No PFK TrailTime Remaining : 0 days 0 hours Support Shield State : Yes Block SSD Write Disk Cache Change: Yes Supported VD Operations ================ Read Policy : Yes Write Policy : Yes IO Policy : Yes Access Policy : Yes Disk Cache Policy : Yes Reconstruction : Yes Deny Locate : No Deny CC : No Allow Ctrl Encryption: No Enable LDBBM : No Support Breakmirror : No Power Savings : Yes Supported PD Operations ================ Force Online : Yes Force Offline : Yes Force Rebuild : Yes Deny Force Failed : No Deny Force Good/Bad : No Deny Missing Replace : No Deny Clear : No Deny Locate : No Support Temperature : Yes Disable Copyback : No Enable JBOD : No Enable Copyback on SMART : No Enable Copyback to SSD on SMART Error : Yes Enable SSD Patrol Read : No PR Correct Unconfigured Areas : Yes Enable Spin Down of UnConfigured Drives : Yes Disable Spin Down of hot spares : No Spin Down time : 30 T10 Power State : Yes Error Counters ================ Memory Correctable Errors : 0 Memory Uncorrectable Errors : 0 Cluster Information ================ Cluster Permitted : No Cluster Active : No Default Settings ================ Phy Polarity : 0 Phy PolaritySplit : 0 Background Rate : 30 Strip Size : 64kB Flush Time : 4 seconds Write Policy : WB Read Policy : Adaptive Cache When BBU Bad : Disabled Cached IO : No SMART Mode : Mode 6 Alarm Disable : Yes Coercion Mode : None ZCR Config : Unknown Dirty LED Shows Drive Activity : No BIOS Continue on Error : No Spin Down Mode : None Allowed Device Type : SAS/SATA Mix Allow Mix in Enclosure : Yes Allow HDD SAS/SATA Mix in VD : Yes Allow SSD SAS/SATA Mix in VD : No Allow HDD/SSD Mix in VD : No Allow SATA in Cluster : No Max Chained Enclosures : 16 Disable Ctrl-R : Yes Enable Web BIOS : Yes Direct PD Mapping : No BIOS Enumerate VDs : Yes Restore Hot Spare on Insertion : No Expose Enclosure Devices : Yes Maintain PD Fail History : Yes Disable Puncturing : No Zero Based Enclosure Enumeration : No PreBoot CLI Enabled : Yes LED Show Drive Activity : Yes Cluster Disable : Yes SAS Disable : No Auto Detect BackPlane Enable : SGPIO/i2c SEP Use FDE Only : No Enable Led Header : No Delay during POST : 0 EnableCrashDump : No Disable Online Controller Reset : No EnableLDBBM : No Un-Certified Hard Disk Drives : Allow Treat Single span R1E as R10 : No Max LD per array : 16 Power Saving option : Don't Auto spin down Configured Drives Max power savings option is not allowed for LDs. Only T10 power conditions are to be used. Default spin down time in minutes: 30 Enable JBOD : No TTY Log In Flash : No Auto Enhanced Import : No BreakMirror RAID Support : No Disable Join Mirror : No Enable Shield State : Yes Time taken to detect CME : 60s Exit Code: 0x00 Enclosure information: # /opt/MegaRAID/MegaCli/MegaCli64 -encinfo -a1 Number of enclosures on adapter 1 -- 3 Enclosure 0: Device ID : 36 Number of Slots : 28 Number of Power Supplies : 2 Number of Fans : 3 Number of Temperature Sensors : 1 Number of Alarms : 1 Number of SIM Modules : 0 Number of Physical Drives : 28 Status : Normal Position : 1 Connector Name : Port B Enclosure type : SES VendorId is LSI CORP and Product Id is SAS2X36 VendorID and Product ID didnt match FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : 65 Inquiry data : Vendor Identification : LSI CORP Product Identification : SAS2X36 Product Revision Level : 0718 Vendor Specific : x36-55.7.24.1 Number of Voltage Sensors :2 Voltage Sensor :0 Voltage Sensor Status :OK Voltage Value :5020 milli volts Voltage Sensor :1 Voltage Sensor Status :OK Voltage Value :11820 milli volts Number of Power Supplies : 2 Power Supply : 0 Power Supply Status : OK Power Supply : 1 Power Supply Status : OK Number of Fans : 3 Fan : 0 Fan Speed :Low Speed Fan Status : OK Fan : 1 Fan Speed :Low Speed Fan Status : OK Fan : 2 Fan Speed :Low Speed Fan Status : OK Number of Temperature Sensors : 1 Temp Sensor : 0 Temperature : 48 Temperature Sensor Status : OK Number of Chassis : 1 Chassis : 0 Chassis Status : OK Enclosure 1: Device ID : 65 Number of Slots : 28 Number of Power Supplies : 2 Number of Fans : 3 Number of Temperature Sensors : 1 Number of Alarms : 1 Number of SIM Modules : 0 Number of Physical Drives : 28 Status : Normal Position : 1 Connector Name : Port A Enclosure type : SES VendorId is LSI CORP and Product Id is SAS2X36 VendorID and Product ID didnt match FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : 36 Inquiry data : Vendor Identification : LSI CORP Product Identification : SAS2X36 Product Revision Level : 0718 Vendor Specific : x36-55.7.24.1 Number of Voltage Sensors :2 Voltage Sensor :0 Voltage Sensor Status :OK Voltage Value :5020 milli volts Voltage Sensor :1 Voltage Sensor Status :OK Voltage Value :11760 milli volts Number of Power Supplies : 2 Power Supply : 0 Power Supply Status : OK Power Supply : 1 Power Supply Status : OK Number of Fans : 3 Fan : 0 Fan Speed :Low Speed Fan Status : OK Fan : 1 Fan Speed :Low Speed Fan Status : OK Fan : 2 Fan Speed :Low Speed Fan Status : OK Number of Temperature Sensors : 1 Temp Sensor : 0 Temperature : 47 Temperature Sensor Status : OK Number of Chassis : 1 Chassis : 0 Chassis Status : OK Enclosure 2: Device ID : 252 Number of Slots : 8 Number of Power Supplies : 0 Number of Fans : 0 Number of Temperature Sensors : 0 Number of Alarms : 0 Number of SIM Modules : 1 Number of Physical Drives : 0 Status : Normal Position : 1 Connector Name : Unavailable Enclosure type : SGPIO Failed in first Inquiry commnad FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : Unavailable Inquiry data : Vendor Identification : LSI Product Identification : SGPIO Product Revision Level : N/A Vendor Specific : Exit Code: 0x00 Now, notice that each slot 11 device shows an enclosure ID of 36, I think this is where the discrepancy happens. One should be 36. But the other should be on enclosure 65. Drives in slot 11: Enclosure Device ID: 36 Slot Number: 11 Drive's postion: DiskGroup: 5, Span: 0, Arm: 1 Enclosure position: 0 Device Id: 48 WWN: Sequence Number: 11 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Firmware state: Online, Spun Up Is Commissioned Spare : YES Device Firmware Level: A5C0 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5003048000ee8a53 Connected Port Number: 1(path0) Inquiry Data: MJ1311YNG6YYXAHitachi HDS5C3030ALA630 MEAOA5C0 FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :30C (86.00 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Drive's write cache : Disabled Drive's NCQ setting : Enabled Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No Enclosure Device ID: 36 Slot Number: 11 Drive's postion: DiskGroup: 19, Span: 0, Arm: 1 Enclosure position: 0 Device Id: 19 WWN: Sequence Number: 4 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Firmware state: Online, Spun Up Is Commissioned Spare : NO Device Firmware Level: A580 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5003048000ee8e53 Connected Port Number: 0(path0) Inquiry Data: MJ1313YNG1VA5CHitachi HDS5C3030ALA630 MEAOA580 FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :30C (86.00 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Drive's write cache : Disabled Drive's NCQ setting : Enabled Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No Update 06/28/12: I finally have some new information about (what we think) the root cause of this problem so I thought I would share. After getting in contact with a very knowledgeable Supermicro tech, they provided us with a tool called Xflash (doesn't appear to be readily available on their FTP). When we gathered some information using this utility, my colleague found something very strange: root@mogile2 test]# ./xflash.dat -i get avail Initializing Interface. Expander: SAS2X36 (SAS2x36) 1) SAS2X36 (SAS2x36) (50030480:00EE917F) (0.0.0.0) 2) SAS2X36 (SAS2x36) (50030480:00E9D67F) (0.0.0.0) 3) SAS2X36 (SAS2x36) (50030480:0112D97F) (0.0.0.0) This lists the connected enclosures. You see the 3 connected (we have since added a 3rd and a 4th which is not yet showing up) with their respective SAS address / WWN (50030480:00EE917F). Now we can use this address to get information on the individual enclosures: [root@mogile2 test]# ./xflash.dat -i 5003048000EE917F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:00EE917F Enclosure Logical Id: 50030480:0000007F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 [root@mogile2 test]# ./xflash.dat -i 5003048000E9D67F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:00E9D67F Enclosure Logical Id: 50030480:0000007F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 [root@mogile2 test]# ./xflash.dat -i 500304800112D97F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:0112D97F Enclosure Logical Id: 50030480:0112D97F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 Did you catch it? The first 2 enclosures logical ID is partially masked out where the 3rd one (which has a correct unique enclosure ID) is not. We pointed this out to Supermicro and were able to confirm that this address is supposed to be set during manufacturing and there was a problem with a certain batch of these enclosures where the logical ID was not set. We believe that the RAID controller is determining the ID based on the logical ID and since our first 2 enclosures have the same logical ID, they get the same enclosure ID. We also confirmed that 0000007F is the default which comes from LSI as an ID. The next pointer that helps confirm this could be a manufacturing problem with a run of JBODs is the fact that all 6 of the enclosures that have this problem begin with 00E. I believe that between 00E8 and 00EE Supermicro forgot to program the logical IDs correctly and neglected to recall or fix the problem post production. Fortunately for us, there is a tool to manage the WWN and logical ID of the devices from Supermicro: ftp://ftp.supermicro.com/utility/ExpanderXtools_Lite/. Our next step is to schedule a shutdown of these JBODs (after data migration) and reprogram the logical ID and see if it solves the problem. Update 06/28/12 #2: I just discovered this FAQ at Supermicro while Google searching for "lsi 0000007f": http://www.supermicro.com/support/faqs/faq.cfm?faq=11805. I still don't understand why, in the last several times we contacted Supermicro, they would have never directed us to this article :\

    Read the article

  • Can't detect wireless networks, running ubuntu 9.10 on eeepc 1000he

    - by David Brown
    Hi, I am running Ubuntu 9.10 on an ASUS eeepc 1000HE, and my wireless card, RaLink RT 2860, is failing to recognize any wireless networks. It was working fine this morning, until I accidentally hit Fn F2, disabling the wireless card. I hit Fn F2 again to reenable it, but it no longer will detect any wireless networks (and other computers in the household do recognize them). Any help at all will be greatly appreciated! I googled quite a bit and talked to a human about this but could not fix it. We tried dhclient ra0, which returned There is already a pid file /var/run/dhclient.pid with pid 2438 killed old client process, removed PID file Internet Systems Consortium DHCP Client V3.1.2 Copyright 2004-2008 Internet Systems Consortium. All rights reserved. For info, please visit http://www.isc.org/sw/dhcp/ Listening on LPF/ra0/00:25:d3:13:f4:20 Sending on LPF/ra0/00:25:d3:13:f4:20 Sending on Socket/fallback DHCPDISCOVER on ra0 to 255.255.255.255 port 67 interval 6 DHCPDISCOVER on ra0 to 255.255.255.255 port 67 interval 9 DHCPDISCOVER on ra0 to 255.255.255.255 port 67 interval 12 DHCPDISCOVER on ra0 to 255.255.255.255 port 67 interval 8 DHCPDISCOVER on ra0 to 255.255.255.255 port 67 interval 10 DHCPDISCOVER on ra0 to 255.255.255.255 port 67 interval 10 DHCPDISCOVER on ra0 to 255.255.255.255 port 67 interval 6 No DHCPOFFERS received. No working leases in persistent database - sleeping. Other data: iwconfig returns (other stuff here...) ra0 RT2860 Wireless ESSID:"" Nickname:"RT2860STA" Mode:Auto Frequency=2.412 GHz Bit Rate=1 Mb/s RTS thr:off Fragment thr:off Link Quality=10/100 Signal level:0 dBm Noise level:-87 dBm Rx invalid nwid:0 Rx invalid crypt:0 Rx invalid frag:0 Tx excessive retries:0 Invalid misc:0 Missed beacon:0 ifconfig returns (other stuff here...) ra0 Link encap:Ethernet HWaddr 00:25:d3:13:f4:20 inet6 addr: fe80::225:d3ff:fe13:f420/64 Scope:Link UP BROADCAST MULTICAST MTU:1500 Metric:1 RX packets:0 errors:0 dropped:0 overruns:0 frame:0 TX packets:583 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:1000 RX bytes:0 (0.0 B) TX bytes:0 (0.0 B) Interrupt:19 ra0:avahi Link encap:Ethernet HWaddr 00:25:d3:13:f4:20 inet addr:169.254.7.117 Bcast:169.254.255.255 Mask:255.255.0.0 UP BROADCAST MULTICAST MTU:1500 Metric:1 Interrupt:19

    Read the article

  • JBOSS 7.1 started hanging after 6 months of deployment

    - by PVR
    My application is been live from 6 months. The application is host on jboss 7.1 server. From last few days I am finding numerous problem of hanging of jboss server. Though I restart the jboss server again, it does not invoke. I need to restart the server machine itself. Can anyone please let me know what could be the cause of these problems and the workable resolutions or any suggestion ? Kindly dont degrade the question as I am facing a lot problems due to this hanging issue. Also for the information, the application is based on Java, GWT, Hibernate 3. Please find the standalone.xml file in case if it helps. <extensions> <extension module="org.jboss.as.clustering.infinispan"/> <extension module="org.jboss.as.configadmin"/> <extension module="org.jboss.as.connector"/> <extension module="org.jboss.as.deployment-scanner"/> <extension module="org.jboss.as.ee"/> <extension module="org.jboss.as.ejb3"/> <extension module="org.jboss.as.jaxrs"/> <extension module="org.jboss.as.jdr"/> <extension module="org.jboss.as.jmx"/> <extension module="org.jboss.as.jpa"/> <extension module="org.jboss.as.logging"/> <extension module="org.jboss.as.mail"/> <extension module="org.jboss.as.naming"/> <extension module="org.jboss.as.osgi"/> <extension module="org.jboss.as.pojo"/> <extension module="org.jboss.as.remoting"/> <extension module="org.jboss.as.sar"/> <extension module="org.jboss.as.security"/> <extension module="org.jboss.as.threads"/> <extension module="org.jboss.as.transactions"/> <extension module="org.jboss.as.web"/> <extension module="org.jboss.as.webservices"/> <extension module="org.jboss.as.weld"/> </extensions> <system-properties> <property name="org.apache.coyote.http11.Http11Protocol.COMPRESSION" value="on"/> <property name="org.apache.coyote.http11.Http11Protocol.COMPRESSION_MIME_TYPES" value="text/javascript,text/css,text/html,text/xml,text/json"/> </system-properties> <management> <security-realms> <security-realm name="ManagementRealm"> <authentication> <properties path="mgmt-users.properties" relative-to="jboss.server.config.dir"/> </authentication> </security-realm> <security-realm name="ApplicationRealm"> <authentication> <properties path="application-users.properties" relative-to="jboss.server.config.dir"/> </authentication> </security-realm> </security-realms> <management-interfaces> <native-interface security-realm="ManagementRealm"> <socket-binding native="management-native"/> </native-interface> <http-interface security-realm="ManagementRealm"> <socket-binding http="management-http"/> </http-interface> </management-interfaces> </management> <profile> <subsystem xmlns="urn:jboss:domain:logging:1.1"> <console-handler name="CONSOLE"> <level name="INFO"/> <formatter> <pattern-formatter pattern="%d{HH:mm:ss,SSS} %-5p [%c] (%t) %s%E%n"/> </formatter> </console-handler> <periodic-rotating-file-handler name="FILE"> <formatter> <pattern-formatter pattern="%d{HH:mm:ss,SSS} %-5p [%c] (%t) %s%E%n"/> </formatter> <file relative-to="jboss.server.log.dir" path="server.log"/> <suffix value=".yyyy-MM-dd"/> <append value="true"/> </periodic-rotating-file-handler> <logger category="com.arjuna"> <level name="WARN"/> </logger> <logger category="org.apache.tomcat.util.modeler"> <level name="WARN"/> </logger> <logger category="sun.rmi"> <level name="WARN"/> </logger> <logger category="jacorb"> <level name="WARN"/> </logger> <logger category="jacorb.config"> <level name="ERROR"/> </logger> <root-logger> <level name="INFO"/> <handlers> <handler name="CONSOLE"/> <handler name="FILE"/> </handlers> </root-logger> </subsystem> <subsystem xmlns="urn:jboss:domain:configadmin:1.0"/> <subsystem xmlns="urn:jboss:domain:datasources:1.0"> <datasources> <datasource jndi-name="java:jboss/datasources/ExampleDS" pool-name="ExampleDS" enabled="true" use-java-context="true"> <connection-url>jdbc:h2:mem:test;DB_CLOSE_DELAY=-1</connection-url> <driver>h2</driver> <security> <user-name>sa</user-name> <password>sa</password> </security> </datasource> <drivers> <driver name="h2" module="com.h2database.h2"> <xa-datasource-class>org.h2.jdbcx.JdbcDataSource</xa-datasource-class> </driver> </drivers> </datasources> </subsystem> <subsystem xmlns="urn:jboss:domain:deployment-scanner:1.1"> <deployment-scanner path="deployments" relative-to="jboss.server.base.dir" scan-interval="5000"/> </subsystem> <subsystem xmlns="urn:jboss:domain:ee:1.0"/> <subsystem xmlns="urn:jboss:domain:ejb3:1.2"> <session-bean> <stateless> <bean-instance-pool-ref pool-name="slsb-strict-max-pool"/> </stateless> <stateful default-access-timeout="5000" cache-ref="simple"/> <singleton default-access-timeout="5000"/> </session-bean> <pools> <bean-instance-pools> <strict-max-pool name="slsb-strict-max-pool" max-pool-size="20" instance-acquisition-timeout="5" instance-acquisition-timeout-unit="MINUTES"/> <strict-max-pool name="mdb-strict-max-pool" max-pool-size="20" instance-acquisition-timeout="5" instance-acquisition-timeout-unit="MINUTES"/> </bean-instance-pools> </pools> <caches> <cache name="simple" aliases="NoPassivationCache"/> <cache name="passivating" passivation-store-ref="file" aliases="SimpleStatefulCache"/> </caches> <passivation-stores> <file-passivation-store name="file"/> </passivation-stores> <async thread-pool-name="default"/> <timer-service thread-pool-name="default"> <data-store path="timer-service-data" relative-to="jboss.server.data.dir"/> </timer-service> <remote connector-ref="remoting-connector" thread-pool-name="default"/> <thread-pools> <thread-pool name="default"> <max-threads count="10"/> <keepalive-time time="100" unit="milliseconds"/> </thread-pool> </thread-pools> </subsystem> <subsystem xmlns="urn:jboss:domain:infinispan:1.2" default-cache-container="hibernate"> <cache-container name="hibernate" default-cache="local-query"> <local-cache name="entity"> <transaction mode="NON_XA"/> <eviction strategy="LRU" max-entries="10000"/> <expiration max-idle="100000"/> </local-cache> <local-cache name="local-query"> <transaction mode="NONE"/> <eviction strategy="LRU" max-entries="10000"/> <expiration max-idle="100000"/> </local-cache> <local-cache name="timestamps"> <transaction mode="NONE"/> <eviction strategy="NONE"/> </local-cache> </cache-container> </subsystem> <subsystem xmlns="urn:jboss:domain:jaxrs:1.0"/> <subsystem xmlns="urn:jboss:domain:jca:1.1"> <archive-validation enabled="true" fail-on-error="true" fail-on-warn="false"/> <bean-validation enabled="true"/> <default-workmanager> <short-running-threads> <core-threads count="50"/> <queue-length count="50"/> <max-threads count="50"/> <keepalive-time time="10" unit="seconds"/> </short-running-threads> <long-running-threads> <core-threads count="50"/> <queue-length count="50"/> <max-threads count="50"/> <keepalive-time time="100" unit="seconds"/> </long-running-threads> </default-workmanager> <cached-connection-manager/> </subsystem> <subsystem xmlns="urn:jboss:domain:jdr:1.0"/> <subsystem xmlns="urn:jboss:domain:jmx:1.1"> <show-model value="true"/> <remoting-connector/> </subsystem> <subsystem xmlns="urn:jboss:domain:jpa:1.0"> <jpa default-datasource=""/> </subsystem> <subsystem xmlns="urn:jboss:domain:mail:1.0"> <mail-session jndi-name="java:jboss/mail/Default"> <smtp-server outbound-socket-binding-ref="mail-smtp"/> </mail-session> </subsystem> <subsystem xmlns="urn:jboss:domain:naming:1.1"/> <subsystem xmlns="urn:jboss:domain:osgi:1.2" activation="lazy"> <properties> <property name="org.osgi.framework.startlevel.beginning"> 1 </property> </properties> <capabilities> <capability name="javax.servlet.api:v25"/> <capability name="javax.transaction.api"/> <capability name="org.apache.felix.log" startlevel="1"/> <capability name="org.jboss.osgi.logging" startlevel="1"/> <capability name="org.apache.felix.configadmin" startlevel="1"/> <capability name="org.jboss.as.osgi.configadmin" startlevel="1"/> </capabilities> </subsystem> <subsystem xmlns="urn:jboss:domain:pojo:1.0"/> <subsystem xmlns="urn:jboss:domain:remoting:1.1"> <connector name="remoting-connector" socket-binding="remoting" security-realm="ApplicationRealm"/> </subsystem> <subsystem xmlns="urn:jboss:domain:resource-adapters:1.0"/> <subsystem xmlns="urn:jboss:domain:sar:1.0"/> <subsystem xmlns="urn:jboss:domain:security:1.1"> <security-domains> <security-domain name="other" cache-type="default"> <authentication> <login-module code="Remoting" flag="optional"> <module-option name="password-stacking" value="useFirstPass"/> </login-module> <login-module code="RealmUsersRoles" flag="required"> <module-option name="usersProperties" value="${jboss.server.config.dir}/application-users.properties"/> <module-option name="rolesProperties" value="${jboss.server.config.dir}/application-roles.properties"/> <module-option name="realm" value="ApplicationRealm"/> <module-option name="password-stacking" value="useFirstPass"/> </login-module> </authentication> </security-domain> <security-domain name="jboss-web-policy" cache-type="default"> <authorization> <policy-module code="Delegating" flag="required"/> </authorization> </security-domain> <security-domain name="jboss-ejb-policy" cache-type="default"> <authorization> <policy-module code="Delegating" flag="required"/> </authorization> </security-domain> </security-domains> </subsystem> <subsystem xmlns="urn:jboss:domain:threads:1.1"/> <subsystem xmlns="urn:jboss:domain:transactions:1.1"> <core-environment> <process-id> <uuid/> </process-id> </core-environment> <recovery-environment socket-binding="txn-recovery-environment" status-socket-binding="txn-status-manager"/> <coordinator-environment default-timeout="300"/> </subsystem> <subsystem xmlns="urn:jboss:domain:web:1.1" default-virtual-server="default-host" native="false"> <connector name="http" protocol="HTTP/1.1" scheme="http" socket-binding="http"/> <virtual-server name="default-host" enable-welcome-root="false"> <alias name="localhost"/> <alias name="nextenders.com"/> </virtual-server> </subsystem> <subsystem xmlns="urn:jboss:domain:webservices:1.1"> <modify-wsdl-address>true</modify-wsdl-address> <wsdl-host>${jboss.bind.address:127.0.0.1}</wsdl-host> <endpoint-config name="Standard-Endpoint-Config"/> <endpoint-config name="Recording-Endpoint-Config"> <pre-handler-chain name="recording-handlers" protocol-bindings="##SOAP11_HTTP ##SOAP11_HTTP_MTOM ##SOAP12_HTTP ##SOAP12_HTTP_MTOM"> <handler name="RecordingHandler" class="org.jboss.ws.common.invocation.RecordingServerHandler"/> </pre-handler-chain> </endpoint-config> </subsystem> <subsystem xmlns="urn:jboss:domain:weld:1.0"/> </profile> <interfaces> <interface name="management"> <inet-address value="${jboss.bind.address.management:127.0.0.1}"/> </interface> <interface name="public"> <inet-address value="${jboss.bind.address:127.0.0.1}"/> </interface> <interface name="unsecure"> <inet-address value="${jboss.bind.address.unsecure:127.0.0.1}"/> </interface> </interfaces> <socket-binding-group name="standard-sockets" default-interface="public" port-offset="${jboss.socket.binding.port-offset:0}"> <socket-binding name="management-native" interface="management" port="${jboss.management.native.port:9999}"/> <socket-binding name="management-http" interface="management" port="${jboss.management.http.port:9990}"/> <socket-binding name="management-https" interface="management" port="${jboss.management.https.port:9443}"/> <socket-binding name="ajp" port="8009"/> <socket-binding name="http" port="80"/> <socket-binding name="https" port="443"/> <socket-binding name="osgi-http" interface="management" port="8090"/> <socket-binding name="remoting" port="4447"/> <socket-binding name="txn-recovery-environment" port="4712"/> <socket-binding name="txn-status-manager" port="4713"/> <outbound-socket-binding name="mail-smtp"> <remote-destination host="localhost" port="25"/> </outbound-socket-binding> </socket-binding-group>

    Read the article

  • How to Read Device Data From COM

    - by Aamir Khurshid
    I have one device which sends data on COM port say on COM13, now i want to read that data and display it in the RichtextBox or in any text control , i have written the application with the help of IO and IO.Ports but comport.DataRecived event does not fire,even though device is sending data on that port, I have some software on which i define the port number and it successfully display data ,which insure me that data is reciving on the Port but i am unable to recive, is there any way i can read data? Regards, Aamir

    Read the article

  • Forward all traffic through an ssh tunnel

    - by Eamorr
    I hope someone can follow this and I'll explain as best I can. I'm trying to forward all traffic from port 6999 on x.x.x.224, through an ssh tunnel, and onto port 7000 on x.x.x.218. Here is some ASCII art: |browser|-----|Squid on x.x.x.224|------|ssh tunnel|------<satellite link>-----|Squid on x.x.x.218|-----|www| 3128 6999 7000 80 When I remove the ssh tunnel, everything works fine. The idea is to turn off encryption on the ssh tunnel (to save bandwidth) and turn on maximum compression (to save more bandwidth). This is because it's a satellite link. Here's the ssh tunnel I've been using: ssh -C -f -C -o CompressionLevel=9 -o Cipher=none [email protected] -L 7000:172.16.1.224:6999 -N The trouble is, I don't know how to get data from Squid on x.x.x.224 into the ssh tunnel? Am I going about this the wrong way? Should I create an ssh tunnel on x.x.x.218? I use iptables to stop squid on x.x.x.224 from reading port 80, but to feed from port 6999 instead (i.e. via the ssh tunnel). Do I need another iptables rule? Any comments greatly appreciated. Many thanks in advance, Regarding Eduardo Ivanec's question, here is a netstat -i any port 7000 -nn dump from x.x.x.218: 14:42:15.386462 IP 172.16.1.224.40006 > 172.16.1.218.7000: Flags [S], seq 2804513708, win 14600, options [mss 1460,sackOK,TS val 86702647 ecr 0,nop,wscale 4], length 0 14:42:15.386690 IP 172.16.1.218.7000 > 172.16.1.224.40006: Flags [R.], seq 0, ack 2804513709, win 0, length 0 Update 2: When I run the second command, I get the following error in my browser: ERROR The requested URL could not be retrieved The following error was encountered while trying to retrieve the URL: http://109.123.109.205/index.php Zero Sized Reply Squid did not receive any data for this request. Your cache administrator is webmaster. Generated Fri, 01 Jul 2011 16:06:06 GMT by remote-site (squid/2.7.STABLE9) remote-site is 172.16.1.224 When I do a tcpdump -i any port 7000 -nn I get the following: root@remote-site:~# tcpdump -i any port 7000 -nn tcpdump: verbose output suppressed, use -v or -vv for full protocol decode listening on any, link-type LINUX_SLL (Linux cooked), capture size 65535 bytes channel 2: open failed: connect failed: Connection refused channel 2: open failed: connect failed: Connection refused channel 2: open failed: connect failed: Connection refused channel 2: open failed: connect failed: Connection refused channel 2: open failed: connect failed: Connection refused channel 2: open failed: connect failed: Connection refused channel 2: open failed: connect failed: Connection refused channel 2: open failed: connect failed: Connection refused channel 2: open failed: connect failed: Connection refused channel 2: open failed: connect failed: Connection refused channel 2: open failed: connect failed: Connection refused

    Read the article

  • Installing Yaws server on Ubuntu 12.04 (Using a cloud service)

    - by Lee Torres
    I'm trying to get a Yaws web server working on a cloud service (Amazon AWS). I've compilled and installed a local copy on the server. My problem is that I can't get Yaws to run while running on either port 8000 or port 80. I have the following configuration in yaws.conf: port = 8000 listen = 0.0.0.0 docroot = /home/ubuntu/yaws/www/test dir_listings = true This produces the following successful launch/result: Eshell V5.8.5 (abort with ^G) =INFO REPORT==== 16-Sep-2012::17:21:06 === Yaws: Using config file /home/ubuntu/yaws.conf =INFO REPORT==== 16-Sep-2012::17:21:06 === Ctlfile : /home/ubuntu/.yaws/yaws/default/CTL =INFO REPORT==== 16-Sep-2012::17:21:06 === Yaws: Listening to 0.0.0.0:8000 for <3> virtual servers: - http://domU-12-31-39-0B-1A-F6:8000 under /home/ubuntu/yaws/www/trial - =INFO REPORT==== 16-Sep-2012::17:21:06 === Yaws: Listening to 0.0.0.0:4443 for <1> virtual servers: - When I try to access the the url (http://ec2-72-44-47-235.compute-1.amazonaws.com), it never connects. I've tried using paping to check if port 80 or 8000 is open(http://code.google.com/p/paping/) and I get a "Host can not be resolved" error, so obviously something isn't working. I've also tried setting the yaws.conf so its at Port 80, appearing like this: port = 8000 listen = 0.0.0.0 docroot = /home/ubuntu/yaws/www/test dir_listings = true and I get the following error: =ERROR REPORT==== 16-Sep-2012::17:24:47 === Yaws: Failed to listen 0.0.0.0:80 : {error,eacces} =ERROR REPORT==== 16-Sep-2012::17:24:47 === Can't listen to socket: {error,eacces} =ERROR REPORT==== 16-Sep-2012::17:24:47 === Top proc died, terminate gserv =ERROR REPORT==== 16-Sep-2012::17:24:47 === Top proc died, terminate gserv =INFO REPORT==== 16-Sep-2012::17:24:47 === application: yaws exited: {shutdown,{yaws_app,start,[normal,[]]}} type: permanent {"Kernel pid terminated",application_controller," {application_start_failure,yaws,>>>>>>{shutdown,>{yaws_app,start,[normal,[]]}}}"} I've also opened up the port 80 using iptables. Running sudo iptables -L gives this output: Chain INPUT (policy ACCEPT) target prot opt source destination ACCEPT tcp -- ip-192-168-2-0.ec2.internal ip-192-168-2-16.ec2.internal tcp dpt:http ACCEPT tcp -- 0.0.0.0 anywhere tcp dpt:http ACCEPT all -- anywhere anywhere ctstate RELATED,ESTABLISHED ACCEPT tcp -- anywhere anywhere tcp dpt:http ACCEPT tcp -- anywhere anywhere tcp dpt:http Chain FORWARD (policy ACCEPT) target prot opt source destination Chain OUTPUT (policy ACCEPT) target prot opt source destination In addition, I've gone to the security group panel in the Amazon AWS configuration area, and add ports 80, 8000, and 8080 to ip source 0.0.0.0 Please note: if you try to access the URL of the virtual server now, it likely won't connect because I'm not running currently running the yaws daemon. I've tested it when I've run yaws either through yaws or yaws -i Thanks for the patience

    Read the article

  • Link aggregation with freebsd8 and a cicso 3550, what am i doing wrong?

    - by Flamewires
    Hey, I am trying to setup Link Aggrigation with LACP (well, anything that provides increased bandwidth and failover using my setup will work). I'm running FreeBSD 8.0 on 3 machines. M1 is running 2 10/100 ethernetcards setup for link aggrigation using lagg. for reference: ifconfig em0 up ifconfig tx0 up ifconfig create lagg0 ifconfig lagg0 laggproto lacp laggport tx0 laggport em0 192.168.1.16 netmask 255.255.255.0 I plugged them into ports 1 and 2 of a Cicso 3550. then ran: configure terminal interface range Fa0/1 - 2 switchport mode access switchport access vlan 1 channel-group 1 mode active (everythings in vlan 1) Now Im able to connect the other computers to other ports on the switch and failover works great, i can unplug cables in the middle of a transfer and the traffic gets rerouted. However, im not noticing any speed increase. My test setup: load balancing: i tried dst and src on the switch, neither seemed to give me a speed increase. I am SCPing 2 500 meg files from the lagg computer to other computers (one each) which are also running 10/100 full duplex cards. I get transfer speeds of about 11.2-11.4 Mbps to a single host, and about half that (5.9-6.2) Mbps when transferring to both at the same time. From what I understood with destination load balancing the router was suppose to balance traffic headed for 1 computer over 1 port and traffic headed for another over a diff(in this case) the other port. With destination-MAC address forwarding, when packets are forwarded to an EtherChannel, the packets are distributed across the ports in the channel based on the destination host MAC address of the incoming packet. Therefore, packets to the same destination are forwarded over the same port, and packets to a different destination are sent on a different port in the channel. For the 3550 series switch, when source-MAC address forwarding is used, load distribution based on the source and destination IP address is also enabled for routed IP traffic. All routed IP traffic chooses a port based on the source and destination IP address. Packets between two IP hosts always use the same port in the channel, and traffic between any other pair of hosts can use a different port in the channel. (Link) What am i doing wrong/what would i need to do to see a speed increase beyond what i could do with just a single card?

    Read the article

  • Glassfish V3 won't start

    - by Zakaria
    Hi everybody, I installed NetBeans 6.8 and tried to run the GlasshFish V3 server. I'm working under Windows Vista 32 Bits. First, it won't run. Then I modified the c:\Windows\System32\drivers\etc\hosts file and put the following line into it: 127.0.0.1 localhost And when I run the GlasshFish V3 Server, no error is showing but only "INFOs" are displayed: 3 avr. 2010 19:23:19 com.sun.enterprise.glassfish.bootstrap.ASMain main INFO: Launching GlassFish on Felix platform Welcome to Felix ================ INFO: Perform lazy SSL initialization for the listener 'http-listener-2' INFO: Starting Grizzly Framework 1.9.18-k - Sat Apr 03 19:23:24 CEST 2010 INFO: Starting Grizzly Framework 1.9.18-k - Sat Apr 03 19:23:25 CEST 2010 INFO: Grizzly Framework 1.9.18-k started in: 423ms listening on port 35127 INFO: GlassFish v3 (74.2) startup time : Felix(4456ms) startup services(1709ms) total(6165ms) INFO: Grizzly Framework 1.9.18-k started in: 459ms listening on port 35116 INFO: Grizzly Framework 1.9.18-k started in: 428ms listening on port 35155 INFO: Grizzly Framework 1.9.18-k started in: 470ms listening on port 35160 INFO: Grizzly Framework 1.9.18-k started in: 513ms listening on port 35159 INFO: javassist.util.proxy.ProxyFactory.classLoaderProvider = org.glassfish.weld.WeldActivator$GlassFishClassLoaderProvider@5be8f4 INFO: Hibernate Validator bean-validator-3.0-JBoss-4.0.2 INFO: Binding RMI port to *:35165 INFO: Instantiated an instance of org.hibernate.validator.engine.resolver.JPATraversableResolver. INFO: JMXStartupService: Started JMXConnector, JMXService URL = service:jmx:rmi://PC-de-Charlotte:35165/jndi/rmi://PC-de-Charlotte:35165/jmxrmi INFO: Using com.sun.enterprise.transaction.jts.JavaEETransactionManagerJTSDelegate as the delegate INFO: [Thread[GlassFish Kernel Main Thread,5,main]] started INFO: Grizzly Framework 1.9.18-k started in: 150ms listening on port 35159 INFO: Perform lazy SSL initialization for the listener 'http-listener-2' INFO: {felix.fileinstall.poll (ms) = 5000, felix.fileinstall.dir = C:\Program Files\sges-v3\glassfish\modules\autostart, felix.fileinstall.debug = 1, felix.fileinstall.bundles.new.start = true, felix.fileinstall.tmpdir = C:\Users\CHARLO~1\AppData\Local\Temp\fileinstall-330907148519261411, felix.fileinstall.filter = null} INFO: {felix.fileinstall.poll (ms) = 5000, felix.fileinstall.dir = C:\Users\Charlotte\.netbeans\6.8\GlassFish_v3\autodeploy\bundles, felix.fileinstall.debug = 1, felix.fileinstall.bundles.new.start = true, felix.fileinstall.tmpdir = C:\Users\CHARLO~1\AppData\Local\Temp\fileinstall-2938963288421854459, felix.fileinstall.filter = null} INFO: Grizzly Framework 1.9.18-k started in: 95ms listening on port 35160 INFO: Updating configuration from org.apache.felix.fileinstall-autodeploy-bundles.cfg INFO: Installed C:\Program Files\sges-v3\glassfish\modules\autostart\org.apache.felix.fileinstall-autodeploy-bundles.cfg INFO: {felix.fileinstall.poll (ms) = 5000, felix.fileinstall.dir = C:\Users\Charlotte\.netbeans\6.8\GlassFish_v3\autodeploy\bundles, felix.fileinstall.debug = 1, felix.fileinstall.bundles.new.start = true, felix.fileinstall.tmpdir = C:\Users\CHARLO~1\AppData\Local\Temp\fileinstall-6474085409014899009, felix.fileinstall.filter = null} And there is no message such as "Glassfish started"! So, when I try to access to the admin web interface: localhost:4848 or localhost:8080 or localhost:8181 , It doesn't work. What should I do? Thank you very much, Regards.

    Read the article

  • Making application behind reverse proxy aware of https

    - by akaIDIOT
    https in tomcat being the hassel it is, I've been trying to get an Axis2 webapp to work behind a reverse proxy for ages now, can't seem to get it to work. The proxying itself works like a charm, but the app fails to generate 'links' (or ports as it concerns SOAP) using https. It would seem I need some way to let Axis2 know it is being accessed through https, even though the actual transport to it is done over http (proxied from localhost). The nginx config that proxies https to localhost:8080: server { listen 443; server_name localhost; ssl on; ssl_certificate /path/to/.pem ssl_certificate_key /path/to/.key; ssl_session_timeout 5m; ssl_protocols SSLv3 TLSv1; ssl_ciphers ALL:!ADH:!EXPORT56:RC4+RSA:+HIGH:+MEDIUM:+LOW:+SSLv3:+EXP; ssl_prefer_server_ciphers on; location / { # force some http-headers (avoid confusing tomcat) proxy_set_header X-Real-IP $remote_addr; proxy_set_header Host $http_host; proxy_set_header X-Forwarded-For $proxy_add_x_forwarded_for; proxy_set_header X-Forwarded-Proto https; # pass requests to local tomcat server listening on default port 8080 proxy_pass http://localhost:8080; } } The proxy itself works fine, the info pages of the webapp work. The problem lies in the ports generated in the .wsdl: <wsdl:service name="WebService"> <wsdl:port name="WebServiceHttpSoap11Endpoint" binding="ns:WebServiceSoap11Binding"> <soap:address location="http://10.10.3.96/axis2/services/WebService.WebServiceHttpSoap11Endpoint/"/> </wsdl:port> <wsdl:port name="WebServiceHttpSoap12Endpoint" binding="ns:WebServiceSoap12Binding"> <soap12:address location="http://10.10.3.96/axis2/services/WebService.WebServiceHttpSoap12Endpoint/"/> </wsdl:port> <wsdl:port name="WebServiceHttpEndpoint" binding="ns:WebServiceHttpBinding"> <http:address location="http://10.10.3.96/axis2/services/WebService.WebServiceHttpEndpoint/"/> </wsdl:port> </wsdl:service> The Host header does its job; it shows 10.10.3.96 in stead of localhost, but as the snippet shows: it says http:// in front of it in stead of https://. My client app can't deal with this... Adding proxyPort and proxyName to the tomcat6 server.xml in the default <Connector> doesn't help; I'm at a loss on how to get this to work properly.

    Read the article

  • Why apcupsd won't see the UPS connected to the USB posrt on FreeBSD 8.0 amd64

    - by Max Kosyakov
    Hello, Recently I installed an apcusbd on a FreeBSD 8.0 amd64 box via ports system. It installed perfectly but it won't run. Here what is says in the log: FATAL ERROR in generic-usb.c at line 636 Cannot find UPS device It appeared that HID driver picked the /dev/ugen4.2 which could cause the apcusb being unable to find the device. After I had discovered this, I rebuilt the kernel and removed the hid driver. Now it just shows "ugen4.2: <Tripp Lite> at usbus4" and no uhid0 device appears. Nevertheless the problem persisted. I tried to leave the DEVICE config setting blank --- won't help. Then I specified the particular device in the config, but it did not help either. Below you is the output of several commands that can provide some useful information on my case. server# /usr/local/etc/rc.d/apcupsd start Starting apcupsd. server# tail /var/log/messages | grep apcupsd Jun 17 22:30:00 server apcupsd[1520]: apcupsd FATAL ERROR in generic-usb.c at line 636 Cannot find UPS device -- For a link to detailed USB trouble shooting information, please see . Jun 17 22:30:00 server apcupsd[1520]: apcupsd error shutdown completed server# cat /usr/local/etc/apcupsd/apcupsd.conf ## apcupsd.conf v1.1 ## UPSCABLE usb UPSTYPE usb DEVICE /dev/ugen4.2 LOCKFILE /var/lock UPSCLASS standalone UPSMODE disable server# dmesg | grep '^u' uhci0: port 0xa800-0xa81f irq 16 at device 26.0 on pci0 uhci0: [ITHREAD] uhci0: LegSup = 0x0f00 usbus0: on uhci0 uhci1: port 0xa880-0xa89f irq 21 at device 26.1 on pci0 uhci1: [ITHREAD] uhci1: LegSup = 0x0f00 usbus1: on uhci1 uhci2: port 0xac00-0xac1f irq 18 at device 26.2 on pci0 uhci2: [ITHREAD] uhci2: LegSup = 0x0f00 usbus2: on uhci2 usbus3: EHCI version 1.0 usbus3: on ehci0 uhci3: port 0xa080-0xa09f irq 23 at device 29.0 on pci0 uhci3: [ITHREAD] uhci3: LegSup = 0x0f00 usbus4: on uhci3 uhci4: port 0xa400-0xa41f irq 19 at device 29.1 on pci0 uhci4: [ITHREAD] uhci4: LegSup = 0x0f00 usbus5: on uhci4 uhci5: port 0xa480-0xa49f irq 18 at device 29.2 on pci0 uhci5: [ITHREAD] uhci5: LegSup = 0x0f00 usbus6: on uhci5 usbus7: EHCI version 1.0 usbus7: on ehci1 uart0: port 0x3f8-0x3ff irq 4 flags 0x10 on acpi0 uart0: [FILTER] usbus0: 12Mbps Full Speed USB v1.0 usbus1: 12Mbps Full Speed USB v1.0 usbus2: 12Mbps Full Speed USB v1.0 usbus3: 480Mbps High Speed USB v2.0 usbus4: 12Mbps Full Speed USB v1.0 usbus5: 12Mbps Full Speed USB v1.0 usbus6: 12Mbps Full Speed USB v1.0 usbus7: 480Mbps High Speed USB v2.0 ugen0.1: at usbus0 uhub0: on usbus0 ugen1.1: at usbus1 uhub1: on usbus1 ugen2.1: at usbus2 uhub2: on usbus2 ugen3.1: at usbus3 uhub3: on usbus3 ugen4.1: at usbus4 uhub4: on usbus4 ugen5.1: at usbus5 uhub5: on usbus5 ugen6.1: at usbus6 uhub6: on usbus6 ugen7.1: at usbus7 uhub7: on usbus7 uhub0: 2 ports with 2 removable, self powered uhub1: 2 ports with 2 removable, self powered uhub2: 2 ports with 2 removable, self powered uhub4: 2 ports with 2 removable, self powered uhub5: 2 ports with 2 removable, self powered uhub6: 2 ports with 2 removable, self powered uhub3: 6 ports with 6 removable, self powered uhub7: 6 ports with 6 removable, self powered ugen4.2: at usbus4 server#

    Read the article

  • Why won't vyatta allow SMTP through my firewall?

    - by Solignis
    I am setting up a vyatta router on VMware ESXi, But I see to have hit a major snag, I could not get my firewall and NAT to work correctly. I am not sure what was wrong with NAT but it "seems" to be working now. But the firewall is not allowing traffic from my WAN interface (eth0) to my LAN (eth1). I can confirm its the firewall because I disabled all firewall rules and everything worked with just NAT. If put the firewalls (WAN and LAN) back in place nothing can get through to port 25. I am not really sure what the issue could be I am using pretty basic firewall rules, I wrote the rules while looking at the vyatta docs so unless there is something odd with the documentation they "should" be working. Here is my NAT rules so far; vyatta@gateway# show service nat rule 20 { description "Zimbra SNAT #1" outbound-interface eth0 outside-address { address 74.XXX.XXX.XXX } source { address 10.0.0.17 } type source } rule 21 { description "Zimbra SMTP #1" destination { address 74.XXX.XXX.XXX port 25 } inbound-interface eth0 inside-address { address 10.0.0.17 } protocol tcp type destination } rule 100 { description "Default LAN -> WAN" outbound-interface eth0 outside-address { address 74.XXX.XXX.XXX } source { address 10.0.0.0/24 } type source } Then here is my firewall rules, this is where I believe the problem is. vyatta@gateway# show firewall all-ping enable broadcast-ping disable conntrack-expect-table-size 4096 conntrack-hash-size 4096 conntrack-table-size 32768 conntrack-tcp-loose enable ipv6-receive-redirects disable ipv6-src-route disable ip-src-route disable log-martians enable name LAN_in { rule 100 { action accept description "Default LAN -> any" protocol all source { address 10.0.0.0/24 } } } name LAN_out { } name LOCAL { rule 100 { action accept state { established enable } } } name WAN_in { rule 20 { action accept description "Allow SMTP connections to MX01" destination { address 74.XXX.XXX.XXX port 25 } protocol tcp } rule 100 { action accept description "Allow established connections back through" state { established enable } } } name WAN_out { } receive-redirects disable send-redirects enable source-validation disable syn-cookies enable SIDENOTE To test for open ports I have using this website, http://www.yougetsignal.com/tools/open-ports/, it showed port 25 as open without the firewall rules and closed with the firewall rules. UPDATE Just to see if the firewall was working properly I made a rule to block SSH from the WAN interface. When I checked for port 22 on my primary WAN address it said it was still open even though I outright blocked the port. Here is the rule I used; rule 21 { action reject destination { address 74.219.80.163 port 22 } protocol tcp } So now I am convinced either I am doing something wrong or the firewall is not working like it should.

    Read the article

  • Communication protocols in UDP

    - by Betamoo
    After many hours, I have discovered that the given udp server needs the following steps for a successful communication: 1- Send "Start Message" on a given port 2- Wait to receive from server on any port 3- Then the port dedicated to you to send further data to the server equals the port you have received on it + 1 So I am asking if this kind is a known protocol/handshaking, or it is only special to this server?? PS: All above communication were in udp sockets in C# PS: Related to a previous question: http://stackoverflow.com/questions/2757868/about-c-udp-sockets Thanks

    Read the article

  • Why can't I connect to remote Microsoft SQL Server through SSH tunnel?

    - by Alexander
    I have at home a D-Link DIR-615 C1 router with DD-WRT. I set up the SSH server on the router, and log on through an SSH2-RSA passphrase-protected key. That router is the gateway between the local network and the internet. One of the computers on that network has Microsoft SQL Server 2008 installed, with TCP/IP protocol enabled through port 1433. I've set up port forwarding on the router, so that remote connections are possible and are, in fact, working (some developers log on remotely without problems). I am part of another network, that has internet access through a proxy server, which only has ports 80 and 443 opened. I can't connect to that MSSQL server on that remote server because 1433 port is closed on this network. I connected (using Putty) through 443 port to my router's SSH server, and set up 2 tunnels. One is for RDP (3389), and it's working. The other is for 1433 port, to connect to the server. I can't connect through the SSH tunnel to the MS SQL Server, neither through telnet, or through GUI clients. Am I missing something? Additional details: on connect, I get this error from SQL Server Management Studio: TITLE: Connect to Server Cannot connect to localhost:14330. ADDITIONAL INFORMATION: A network-related or instance-specific error occurred while establishing a connection to SQL Server. The server was not found or was not accessible. Verify that the instance name is correct and that SQL Server is configured to allow remote connections. (provider: Named Pipes Provider, error: 40 - Could not open a connection to SQL Server) (Microsoft SQL Server, Error: 3) For help, click: http://go.microsoft.com/fwlink?ProdName=Microsoft+SQL+Server&EvtSrc=MSSQLServer&EvtID=3&LinkId=20476 BUTTONS: OK The tunnel is configured like this: L14330 192.168.0.103:1433 192.168.0.103 is the permanent address of the SQL Server on the LAN. I also successfully forwarded TCP traffic of 3389 port to that IP, so tunneling is working to that IP address. When connecting without tunnel, through Microsoft SQL Server Management Studio, using the same method the connection establishes. Too bad my proxy doesn't allow 1433 port traffic, I wouldn't have this headache.

    Read the article