Search Results

Search found 3312 results on 133 pages for 'freebsd ports'.

Page 95/133 | < Previous Page | 91 92 93 94 95 96 97 98 99 100 101 102  | Next Page >

  • Asynchronous event loop design and issues.

    - by Artyom
    Hello, I'm designing event loop for asynchronous socket IO using epoll/devpoll/kqueue/poll/select (including windows-select). I have two options of performing, IO operation: Non-blocking mode, poll on EAGAIN Set socket to non-blocking mode. Read/Write to socket. If operation succeeds, post completion notification to event loop. If I get EAGAIN, add socket to "select list" and poll socket. Polling mode: poll and then execute Add socket to select list and poll it. Wait for notification that it is readable writable read/write Post completion notification to event loop of sucseeds To me it looks like first would require less system calls when using in normal mode, especially for writing to socket (buffers are quite big). Also it looks like that it would be possible to reduce the overhead over number of "select" executions, especially it is nice when you do not have something that scales well as epoll/devpoll/kqueue. Questions: Are there any advantages of the second approach? Are there any portability issues with non-blocking operations on sockets/file descriptors over numerous operating systems: Linux, FreeBSD, Solaris, MacOSX, Windows. Notes: Please do not suggest using existing event-loop/socket-api implementations

    Read the article

  • SSH Password/User problem with Cygwin sshd service

    - by Supernovah
    hello I just set up SSHd through Cygwin on a Windows XP Pro box overseas using a RAT and discluded the openssh package from the install. I ran the cywin shell (from c:\cywin) and ran Now, It's under a port I know is safe and fowarded properly, but I won't share it's number. It's not a common port, but it's under 40000. Firewalls are off etc etc. I'm on the first Admin account made on the box. (It's full admin) I've run the following commands chmod +r /etc/passwd chmod +r /etc/group hmod 777 /var /*Created New Admin User Account To Be Used via SSH*/ mkpasswd -cl > /etc/passwd mkgroup --local > /etc/group I can connect locally, but not externally. I know my ports etc are fine. Any possible problems, as i really need this tunnel up :P

    Read the article

  • Configuring mod_rewrite and mod_jk for Apache 2.2 and JBoss 4.2.3

    - by The Pretender
    Hello! My problem is as follows: I have JBoss 4.2.3 application server with AJP 1.3 connector running on one host under Windows (192.168.1.2 for my test environment) and Apache 2.2.14 running on another FreeBSD box (192.168.1.10). Apache acts as a "front gate" for all requests and sends them to JBoss via mod_jk. Everything was working fine until I had to do some SEO optimizations. These optimizations include SEF urls, so i decided to use mod_rewrite for Apache to alter requests before they are sent to JBoss. Basically, I nedd to implement 2 rules: Redirect old rules like "http://hostname/directory/" to "http://hostname/" with permanent redirect Forward urls like "http://hostname/wtf/123/" to "http://hostname/wtf/view.htm?id=123" so that end user doesn't see the "ugly" URL (the actual rewrite). Here is my Apache config for test virtual host: <VirtualHost *:80> ServerAdmin [email protected] DocumentRoot "/usr/local/www/dummy" ServerName 192.168.1.10 <IfModule mod_rewrite.c> RewriteEngine On RewriteRule /directory/(.*) /$1 [R=permanent,L] RewriteRule ^/([^/]+)/([0-9]+)/?$ /$1/view.htm?id=$2 </IfModule> JkMount /* jsp-hostname ErrorLog "/var/log/dummy-host.example.com-error_log" CustomLog "/var/log/dummy-host.example.com-access_log" common </VirtualHost> The problem is that second rewrite rule doesn't work. Requests slip through to JBoss unchanged, so I get Tomcat 404 error. But if I add redirect flag to the second rule like RewriteRule ^/([^/]+)/([0-9]+)/?$ /$1/view.htm?id=$2 [R,L] it works like a charm. But redirect is not what I need here :) . I suspect that the problem is that requests are forwarded to the another host (192.168.1.2), but I really don't have any idea on how to make it work. Any help would be appreciated :)

    Read the article

  • Using the "naked" attribute for functions in GCC

    - by Art Spasky
    GCC documentation (http://gcc.gnu.org/onlinedocs/gcc/Function-Attributes.html) states in 6.29 Declaring Attributes of Functions "naked Use this attribute on the ARM, AVR, IP2K, RX and SPU ports to indicate that the specified function does not need prologue/epilogue sequences generated by the compiler. It is up to the programmer to provide these sequences. The only statements that can be safely included in naked functions are asm statements that do not have operands. All other statements, including declarations of local variables, if statements, and so forth, should be avoided. Naked functions should be used to implement the body of an assembly function, while allowing the compiler to construct the requisite function declaration for the assembler." Can I safely call functions using C syntax from naked functions, or only by using asm?

    Read the article

  • Intelligent serial port mocks with Moq

    - by Padu Merloti
    I have to write a lot of code that deals with serial ports. Usually there will be a device connected at the other end of the wire and I usually create my own mocks to simulate their behavior. I'm starting to look at Moq to help with my unit tests. It's pretty simple to use it when you need just a stub, but I want to know if it is possible and if yes how do I create a mock for a hardware device that responds differently according to what I want to test. A simple example: One of the devices I interface with receives a command (move to position x), gives back an ACK message and goes to a "moving" state until it reaches the ordered position. I want to create a test where I send the move command and then keep querying state until it reaches the final position. I want to create two versions of the mock for two different tests, one where I expect the device to reach the final position successfully and the other where it will fail. Too much to ask?

    Read the article

  • Synchronizing reading and writing with synchronous NamedPipes

    - by Mike Trader
    A Named Pipe Server is created with hPipe = CreateNamedPipe( zPipePath, PIPE_ACCESS_DUPLEX, PIPE_TYPE_BYTE | PIPE_WAIT | PIPE_READMODE_BYTE, PIPE_UNLIMITED_INSTANCES, 8192, 8192, NMPWAIT_USE_DEFAULT_WAIT, NULL) Then we immediately call: ConnectNamedPipe( hPipe, BYVAL %NULL ) Which blocks until the client connects. Then we proceed directly to ReadFile( hPipe, ... The problem is that it takes the Client takes a finite amount of time to prepare and write all the fcgi request parameters. This has usually not completed before the Pipe Server performs its ReadFile(). The Read file operation thus finds no data in the pipe and the process fails. Is there a mechanism to tell when a Write() has occurred/finished after a client has connected to a NamedPipe? If I had control of the Client process, I could use a common Mutex, but I don't, and I really do not want to get into I/O completion ports just to solve this problem! I can of course use a simple timer to wait 60m/s or so which is usually plenty of time for the wrote to complete, but that is a horrible hack.

    Read the article

  • How to Use 3 Monitors

    - by The.Anti.9
    Right now my setup has a nice big 24" flatscreen in the center, and a 19" flatscreen to the left. And a big gaping hole on the right. I have a 3rd monitor to put there, but I'm not sure how to get the computer to recognize it. Do I need a graphics card with 3 ports? Or can I span the monitors over non SLI-Linked graphics cards? Is it possible to plug my 3rd monitor into the on-board VGA port and have it work?

    Read the article

  • SMS war continues, ideas welcome

    - by Pavel Radzivilovsky
    I am trying to make U9 telit modem send SMS messages. I think I handle protocol correctly, at least, I manage to send them, but only under these circumstances: the native application was executed beforehand, and killed by task manager (without giving it a chance to initialize things). It looks like the supplied application is good at doing certain initialization/deinitialization which is critical. I also see the difference between the two states in output of AT+CIND command. When I am trying to do things on my own, it returns zeroes (including signal quality), but when I run the same command after killing the native application, the output looks reasonable. I am out nearly of ideas. I have tried many things, including attempts to spy at modem's COM ports (didn't work). Haven't tried setting windows hooks to see what the application is trying to get thru. Perhaps you have encountered a similar situation?

    Read the article

  • Virtual drivers with Windows Driver Model - where to begin?

    - by waitinforatrain
    I've never written drivers before but I'm starting an open-source project that involves creating virtual MIDI ports that will send the MIDI data over a network. For this, I presume I would be creating some sort of virtual driver using WDM (unless it's possible with kernel hooks?) - but being a beginner to driver development I don't know where to begin. Does anyone know any useful resources that would help me with this project? Or some open-source code from a similar project that I could fork as a starting point?

    Read the article

  • Trouble getting Flash socket policy file to work.

    - by Alex
    Basically I'm using Flash to connect to a Java server. Despite my Java application replying to the , in the Flash debug log it lists (not sure about the order as there are lots): * Security Sandbox Violation * Connection to 192.168.1.86:4049 halted - not permitted from http://127.0.0.1:8888/Current/wander.swf Warning: Timeout on xmlsocket://192.168.1.86:4049 (at 3 seconds) while waiting for socket policy file. This should not cause any problems, but see http://www.adobe.com/go/strict_policy_files for an explanation. Error: Request for resource at xmlsocket://192.168.1.86:4049 by requestor from http://127.0.0.1:8888/Current/wander.swf is denied due to lack of policy file permissions. What I don't understand is, the server (port 4049) receives the request, outputs the policy file and then closes the connection, surely it shouldn't time out? The policy file I'm using is: <?xml version="1.0"?> <cross-domain-policy><allow-access-from domain="*" to-ports="*" /> </cross-domain-policy>

    Read the article

  • How do I draw an ESB on a SoaML diagram?

    - by dave
    I've recently had to draw some architectural diagrams that feature the use of an Enterprise Service Bus. The ESB is critical, so everyone wants it to show up on the diagram. But since it's the center of what everything is connected to, it really of gets in the way. I settled on trying to use SoaML. I color-coded the request points blue and service points green, to help then stand out. The text names on the ports give you a sense of what talks to what, and it's incredibly obvious that everything goes through the ESB. Can anyone comment on my approach? Any suggestions on something better?

    Read the article

  • Web Application Nat Traversal

    - by pbreault
    We are deploying web applications in java using tomcat on client machines across the country. Once they are installed, we want to allow a remote access to these web applications through a central server, but we do not want our clients to have to open ports on their routers. Is there a way to tunnel the http traffic in a way that the central server can access the web application that is behind the firewall ? The central server has a static ip address and we have full control over it. We don't need to access the filesystem, we only want to access the web application itself through a browser.

    Read the article

  • Connect to https:// webservice in asp.net app

    - by webnoob
    Hi All, I have an ASP.NET website that is contacting a webservice. Everything works fine connecting via http but when I try https:// it can't connect. I don't seem to get any error from the website and the webservice logs show nothing, meaning nothing has connected to it. I can connect to my https:// webservice from a site like soapclient.com and request information, so the webservice and ports are working. Is there anything special I should be doing in order to connect to a https:// webservice over a normal http:// one in .NET? All I am doing at the moment is changing the URL it is connecting to to my secure one instead. I am using ASP.NET 2, IIS7 Thanks in advance.

    Read the article

  • Working with WebKit on Windows

    - by Aram Havarneanu
    Hello, I want to use the WebKit engine in my Win32 application. I can't find any documentation on the official site, or anywhere else. I know it uses COM, but I can't find any documentation about how to use the thing. I know there are multiple WebKit ports for windows. There is the Apple port, to use it you need Safari, there is the Google Chromium port, there is a Cairo port and there is a Qt port. I'll stick to the Apple port for now. Any hints, links? Thanks

    Read the article

  • COM port - how to identify a device (.net/c#)

    - by argh
    Hi, I'm programming for Windows CE and I need to connect to a scanner. There is no problem - I know that it is on port COM0, but if I plug in another device earlier it gets another COM port... to get all com ports the easy way is: SerialPort.GetPortNames() But I don't know how to identify a device? Is there any standard way? I can't 'ping' it since there is one device that only sends data... it spams data all the time... and I don't know how to 'ping' a device...

    Read the article

  • Need help with displaying the message correctly in the pole display

    - by SA
    Hi, I am using an HP RS232 pole display with the following setting: Char type: USA/Europe (default) Command mode: EPSON (default) Baud rate: 9600, n , 8, 1 (default?) Passthru None (Default) Here's the code using System.IO.Ports; private SerialPort port; port = new SerialPort("COM2", 9600, Parity.None, 8, StopBits.One); port.Handshake = Handshake.None; Port.WriteLine("Welocome to something something"); It has 2 lines consisting of 20 characters each with a total of 40 characters. I have no control how and where the characters get displayed. I have set it to accept ASCII char set and so I am able to type as is visble in the Writeline message

    Read the article

  • what causes the .NET SerialPort class DataReceived event to fire?

    - by Klay
    I understand from the MSDN docs that the event DataReceived will not necessarily fire once per byte. But does anyone know what exactly is the mechanism that causes the event to fire? Does the receipt of each byte restart a timer that has to reach, say 10 ms between bytes, before the event fires? I ask because I'm trying to write an app that reads XML data coming in from a serial port. Because my laptop has no serial ports, I use a virtual serial port emulator. (I know, I know--I can't do anything about it ATM). When I pass data through the emulated port to my app, the event fires once for each XML record (about 1500 bytes). Perfect. But when a colleague at another office tries it with two computers connected by an actual cable, the DataReceived event fires repeatedly, after every 10 or so bytes of XML, which totally throws off the app.

    Read the article

  • WebSocket support on mobile devices

    - by Marco W.
    For an Android multiplayer game's communication between players I'm using a WebSocket server and TooTallNate's Java library on the client side to enable WebSocket support in the Android app. So just to point it out clearly, WebSocket support in mobile browsers is not important to me. Unfortunately, users report that they're experiencing problems such as connection failures or unreceived messages. Is that a general problem of WebSockets on mobile devices (blocked ports, firewalls, mobile Internet connection) or is that probably a flaw in the client side code? Do you have experience with WebSocket client libraries such as the one above? I've just discovered autobahn.ws for Android - but I don't know if it's worth switching from my current library (see above). What about WAMP? Is WebSocket technology not exactly the adequate solution so that I should use the sub-protocol (?) WAMP?

    Read the article

  • How to solve JavaScript origin problem with an application and static file server

    - by recipriversexclusion
    In a system that I'm building I want to serve Static files (static HTML pages and a lot of images), and Dynamic XML generated by my servlet. The dynamic XML is generated from my database (through Hibernate) and I use Restlets to serve it in response to API calls. I want to create a static file server (e.g. Apache) so that this does not interfere with the dynamic server traffic. Currently both servers need to run on the same machine. I've never done something like this before and this is where I'm stuck: The static HTML pages contain JavaScript that makes API calls to the dynamic server. However, since the two servers operate on different ports, I get stuck with the same origin problem. How can this be solved? As a bonus, if you can point me to any resources that explain how to create such a static/dynamic content serving system, I'll be happy. Thanks!

    Read the article

  • Is there any kind of standard for 8086 multiprocessing?

    - by Earlz
    Back when I made an 8086 emulator I noticed that there was the LOCK prefix intended for synchonization in a multiprocessor environment. Yet the only multitasking I know of for the x86 arch. involves use of the APIC which didn't come around until either the Pentiums or 486s. Was there any kind of standard for 8086 multitasking or was it done by some manufacturer specific extensions to the instruction set and/or special ports? By standard, I mean things like: How do you separate the 2 processors if they both use the same memory? This is impossible without some kind of way to make each processor execute a different piece of code. (or cause an interrupt on only one processor)

    Read the article

  • Choking experienced while using the TCP/IP Adapter for BizTalk Server 2006

    - by Burhan
    I am using the TCP/IP Adapter for BizTalk Server 2006 which was obtained from codeplex: http://www.codeplex.com/BTSTCPIP Once the application was deployed in production, we started to experience choking in the performance of the application. The more the requests, the more the performance degradation. Sometimes, it happens that the receive ports become non-responsive and we have to forcefully restart the host instances to temporarily let the services respond again but we experience the same problems again and again. I would like to ask if any of you have used the same adapter and have you ever experienced the similar issues? If yes, how can we overcome theses issues. Thanks.

    Read the article

  • Troubleshooting MSSQL Connection from PHP

    - by Cory Dee
    I'm trying to connect to an external Sql Server through PHP 5.2. Using this line: $con = mssql_connect('123.123.123.123','Username','Password') or die('Could not connect to the server!'); I'm receiving this error: Warning: mssql_connect() [function.mssql-connect]: Unable to connect to server: 123.123.123.123 in /home/file/public_html/structure/index.php on line 4 Could not connect to the server! My hosting provider assures me that ports are open for my server to connect to the DB. Looking at my php info, MSSQL Support is enabled, using FreeTDS. Any ideas why this would be failing, or how I can begin trouble shooting the problem?

    Read the article

  • Finding an available network port on the machine

    - by Tomer Vromen
    I'm trying to implement a simple FTP server (a variation of the EFTP protocol) in linux. When a client connects and sends the PASV command, the server should respond with a port number, so the client can connect to that port to transmit the file. How can the server choose a port number? Do I need to iterate through all the ports from 1024 to 65535 until I find a port that the process can bind to? I know that calling bind() with 0 as the port automatically chooses the port to bind to, but then how can I know which port was chosen? Many thanks.

    Read the article

  • controling individual pins on a serial port

    - by Faken
    I know that serial ports work by sending a single stream of bits in serial. I can write programs to send and receive data from that one pin. However, there are a lot more other pins on the serial port connection that normal aren't used but from documentation all seem to have some sort of function for signalling as opposed to data transfer. Is it possible in any way to cause the other pins that are not used for direct data transfer to be controlled individual? If so, how would i go about doing that?

    Read the article

  • MSDTC Distributed Transaction Coordinator Enabling

    - by Curtis White
    I've a web server and a separate SQL server. I'm trying to use transaction scope to ensure that SQL queries are completed with my linq queries. I wrap everything with this using (TransactionScope scope = new TransactionScope()) I want to know where I need to install DTC. Do I need to install it on the IIS 7.5 box AND the SQL server? Do I need to unblock some ports? Are there any security risk in doing so? I've setup this up once before but don't remember how. If I can't get access to DTC then is there any other way to ensure a lINQ and sql query is atomic?

    Read the article

< Previous Page | 91 92 93 94 95 96 97 98 99 100 101 102  | Next Page >